York F*FP User's Manual

image

Contents

1. lt N NOTES 1 Y Terminal on Air Handler Control Board must be connected for full CFM and applications requiring 60 second Blower Off Delay for SEER enhancement 2 Optional Dehumidification Humidistat contacts open on rise 3 For F4FV model Remove Humidistat Jumper on CFM Selection Board if used 4 For F4FV model For Heat Pump Applications Remove Heat Pump Jumper on CFM Selection Board 5 To change quantity of heat during HP defrost cycle Reverse connections at W1 and W2 on Air Handler Control Board 12 Unitary Products Group 295421 YTG B 0707 TYPICAL INSTALLATION SUPPLY POWER WIRING AIR TO MAIN POWER SOURCE REFRIGERANT LINES TO CONDENSATE DRAIN TYPICAL APPLICATIONS UPFLOW OS POWER WIRING CONTROL WIRING THERMOSTAT FILTER ACCESS LOUVERED ELECTRIC HOT WATER HEATER a Must comply with water heater installation instructions HORIZONTAL RIGHT HAND APPLICATION Unitary Products Group LEFT HAND APPLICATION 13 NOTES 295421 YTG B 0707 Unitary Products Group 295421 YTG B 0707 Unitary Products Group NOTES 15 NOTES Subject to change without notice Printed in U S A 295421 YTG B 0707 Copyright O by York Internat
2. aosa 461 42 45 50 e 8 kossn 22 074 4 50 e 8 ossosa 2 41 45 os e 8 akosoa des 475 45 50 e 8 kossies 483 saa 50 6 e 6 eme 46 ea 5 6 e 6 1 O C P Over Current Protection device must be HACR type Circuit Breaker or Time Delay fuse FIELD WIRING CONNECTION COOLING ONLY FIELD WIRING CONNECTION WITH HEATER KIT OUTDOOR OUTDOOR THERMOSTAT THERMOSTAT COIL OOOO0O0O UNIT R Y G W2 W1 UNIT R Y G W2 W1 NOT REQUIRED ON 2 OR 5KW Unitary Products Group 14 295421 YTG B 0707 FIELD WIRING CONNECTIONS COOLING MODELS WITH ELECTRIC HEAT WIRING F SERIES F SERIES Air Handler Control Wiring Air Handler Control Wiring Typical A C Cooling only Applications Typical A C with Electric Heat Applications AIR HANDLER AIR HANDLER THERMOSTAT BOARD 1 STAGE THERMOSTAT BOARD 1 STAGE AIR CONDITIONING AIR CONDITIONING HUMIDISTAT CFM selection 1 CFM selection 1 board only on NOTE board only on NOTE F4FV model Dehumidification FAFV model Dehumidification control connection control connection Humidistat jumper on Humidistat jumper on CFM selection board CFM selection board FIELD WIRING CONNECTIONS SINGLE STAGE HEAT PUMP AIR HANDLER THERMOSTAT BOARD HEAT PUMP HUM HUMIDISTAT CFM selection board only on F4FV model 1 NOTE Dehumidification control connection Humidistat jumper on CFM selection board must be removed
3. 429 3 45 50 8 8 akeno 625 785 ers 60 9 4 8 ak SIS 88 475 48 8 8 keso 417 582 608 60 70 6 4 1 Oor 1 as follows 0 No Breaker 1 Breaker 2 OCP Over Current Protection device must be HACR type Circuit Breaker or Time Delay fuse 3 2HK16501906B only applies to F4FP036 Model Unitary Products Group 9 295421 YTG B 0707 ELECTRICAL DATA 1 Y de A POWER Ed id WIRE Heater Model a and IE tet at at at F4FPO30HO6T2 2HK16501506B 25 25 8 28 7 7 45 145 1 52 1 451 5221 30 30 50 60 E 10 10 8 6 DE avkresoveoss s65 25 4576526 4045 5060 88 a6 FSFPOSOHOSTE 2HKIGSOTSOOS 25287 45 0821 30 0 5080 THO 8 FAFPOAZHOSTZ 20K165015088 28 1805 1821 30 5 5060 108 86 FAFPOASHOSTZ 20K165015068 269293 45 1 821 3080 50060 Toro 86 2HRT5015068 928 955 45 1621 3540 5060 88 86 rsrpossHosTz 2HRT85020088 5536451627 6070 5060 64 86 2HRT65015068 928 955 45 1621 3580 5080 88 86 FsFPosoHoeT2 2HRT85020088 553645627 6070 5060 64 86 2HRT5015068 33 048 45 1621 3585 5080 88 86 FarvosoHosTz 2HRT85020088 5526045627 6070 5060 64 86 1 OCP Over Current Protection device must be HACR type Circuit Breaker or
4. season such as in the southern part of the country On a call for cooling the blower will ramp up to 50 of full capacity and will stay there for two minutes then will ramp up to 82 of full capac ity and will stay there for five minutes and then will ramp up to full capacity where it will stay until the wall thermostat is satisfied In every case it will take the motor 30 seconds to ramp from one speed to another Dry The dry setting is best suited to parts of the country where excessive humidity is not generally a problem where the summer months are usually dry On a call for cooling the motor will ramp up to full capacity and will stay there until the thermostat is satisfied At the end of the cooling cycle the blower will ramp down to 50 of full capacity where it will stay for 60 seconds Then it will ramp down to zero In every case it will take the motor 30 seconds to ramp from one speed to another Temperate The temperate setting is best suited for most of the country where neither excessive humidity nor extremely dry condi tions are the norm On a call for cooling the motor will ramp up to 63 of full capacity and will stay there for 90 seconds then will ramp up to full capacity At the end of the cooling cycle the motor will ramp down to 63 of full capacity and will stay there for 30 seconds then will ramp down to zero In every case it will take the motor 30 seconds to ramp from one speed to another Unitary Pr
5. 685 Mes 1200 1150 1100 1060 085 088 e 795 71 587 High 02 769 645 902 eC o e e Med 1050 1040 065 950 655 eoa 74 62 dot 366 e es seo vo vs oo IE Fh 7575 1500 1 420 1350 1278 192 1 02 986 8 Med 1460 1505 1350 1260 1 190 1125 1062 060 042 eos F4FP036H06T2 F4FP040H06T2 F4FP042H06T2 High 1875 1585 1475 1980 150 285 1 147 1000 87 785 carpossmosrzs Medno 1375 1315 1255 1 785 1 000 1040 00 008 782 006 Medtow 1210 1160 1 110 1 050 980 92 sa 787 60 58 low os 040 65 o 608 66 Sm 2 1801 1815 1777 1741 1681 1618 1539 1453 MedHigh 1948 1904 1801 1815 177 HI F5FP048H06T2 Med 1741 1690 1649 1606 1564 1516 1476 1436 1387 1353 Med Low low i286 1288 177 sido jose i039 987 960 des ma High 2195 2145 2070 2008 1920 1852 1754 1663 1570 1462 F5FP060H06T2 Med 1681 1641 1607 1560 1517 1485 1433 1402 1349 Med Low 1525 1483 1441 1383 1356 914 High 2 195 2 105 2 015 1 950 1 845 1 770 1 685 1 590 1 485 F4FV060H06T2 Med 2 125 2 020 1 910 1 805 1 705 1997 1 491 1 386 1 280 1179 O mea 1 052 NOTE Air flow data shown above 0 50 W C external static pressure is for REFERENCE ONLY Maximum allowable external static when electric heat is used is limited to 0 50 W C Maximum allowable external static pressure may also be limited by minimum CFM requi
6. DIMENSIONS WILL BE PROVIDED UPON REQUEST TOP VIEW ALL MODELS DRAIN PAN FOOTPRINT MAX FILTER LENGTH 21 INCHES MAX FILTER WIDTH B MINUS 1 1 2 INCHES FILTER ACCESS BOTTOM VIEW Refrigerant Connections sa 1 Wiring K O s Line Size L AR IEE Power Cont ro sega ae MS E Mi mam Actual conduit size is shown in parenthesis 14 14 7 8 16 16 12 EE 7 8 1 2 3 8 7 8 20 7 8 22 1 2 7 8 Tao 7 17 3 8 123 52 T 1 2 All models only available with factory installed horizontal drain pan Unitary Products Group 295421 YTG B 0707 COIL TECHNICAL DATA memigerant Fa o ee Tube Tube Meterin Application Connection Area Slab Size G ometty Dia Fin Type la Type Sa Fo quo F4FP024H06T2A A C amp HP F4FP024H06T2B A C amp HP F4FP030H06T2A A C amp HP F4FP036H06T2A A C amp HP F4FP040H06T2A A C amp HP F4FP040H06T2C A C amp HP F4FP042H06T2A A C amp HP F4FP042H06T2C A C amp HP 11 1 AERE COOLING CAPACITY Entering MBH Evaporator Temperature and Corresponding Pressure F Air F PSIG Dry Wet Bulb 35 61 5 40 68 5 45 76 0 50 84 0 Upflow Horizontal Positions Only F4FP024H06T2 F4FP030H06T2 FAFPO36HO6T2 F4FP040H06T2 F4FP042H06T2 F4FP045H06T2 F5FP048H06T2 F5FP060H06T2 F4FV060H06T2 Unitary Products Group 3 ACCESSORIES Refer to Price Manual for specific model numbers VERTICAL SUSPENSION KIT The suspension kit i
7. S 255 ai 5 75 a id 255 55 F4FVOSOHO6T2 05 E NOTE All models available with factory installed horizontal drain pan al O or as follows O No Breaker 1 Breaker See Conversion Table below If first stage heat or 66 is connected to W1 otherwise refer to this table 2HK16501906B only applies to F4FP036 Model AIN KW 8 MBH CONVERSIONS FOR TOTAL POWER INPUT REQUIREMENT 230V OPERATION MULTIPLY 240V TABULATED KW amp MBH BY 8 Unitary Products Group 295421 YTG B 0707 ELECTRICAL DATA 14 SINGLE SOURCE POWER SUPPLY COPPER WIRE Field Wiring E A A Model 2 He Ampacity Amps Type Size AWG een 07 7 9 o 6 enoe 67 er 507 5 6 e 6 omissos 625 798 aoa 6 00 3 cas o ME ME Mm 1 mo oceano 5 97 25 0 e 8 ames ees m9 ere e a 3 masne 739 ass 02 00 wo 9 3 aKos 208 08 287 80 0 10 1 aricesorooss 417 481 57 80 6 8 6 keno 625 709 eos eo 60 4 3 asos 208 21 905 80 10 8 Keso 417 sos 566 60 amp 6 6 mkeo 625 782 ses 60 0 4 3 keso 417 488 555 50 6 8 6 meone 625 797 osa eo 60 4 3 areas ma 28 88 8 5 5 akso did 40 ws 45 50 e 8 assis es m3 ere mw 9 4 5 kieso 653 tomo was mo ws e 1 keso 1042 1209 1988 125 160 1 gt aKes 206 08 se 8 8 8 keso did
8. Time Delay fuse 2 2HK16501906B only applies to F4FP036 Model ELECTRICAL DATA 34 208 230 3 60 MAX STATIC B Totalheat KW Staging Heater Model amp MIN CFM ae W1 Only W2 Only W1 W2 A Y 208V 240V 208V 240V 208V 240V 208V 240V 73 2HKOSSO10258 05 aKes 05 High W3 150 386 512 38 50 75 OO Hs WA carrosongsra 2100o 05 low 75 100 ase oat os 50 75 50 75 too 2FK06501025B 08 how 78 00 206 009 08 sof re 6 78 100 siz as 50 75 TOO Vis jiso akoso 05 low 75 Too we eat os 50 75 50 75 too 2FKOSSO1S258 05 Low 3 150 986 512 88 50 75 100 3150 carrossnosra SEROESONOESS 05 mea 75 Too ase oat os 50 75 50 75 ioo 2HROGSD1S25E EHROESINOESS 05 Wedlow 75 Too we ait os 50 75 50 75 100 siz 35 50 rs oO Vis fiso EHROESITOESS 05 Wed 75 Too ae oat os 50 75 50 75 too EPROESDTSESS 05 Med ne iso 586 ore 35 50 75 TOU via sa 1 See Conversion Table below 2 If first stage heat is connected to W1 66 otherwise refer to Table below F4FP040H06T2 F5FP048H06T2 KW amp MBH CONVERSIONS FOR TOTAL POWER INPUT REQUIREMENT 230V OPERATION MULTIPLY 240V TABULATED KW amp MBH BY 918 10 Unitary Products Group 295421 YTG B 0707 ELECTRICAL DATA 32 SINGLE SOURCE POWERSUPPLY COPPER WIRE Field Wiring FREE INE CT 42 465 amp 8 8 ossosa 2 074 0 e 8
9. ding air filter wet coil and largest KW size heater APPLICATION FACTORS RELATED CFM VS ACTUAL CFM Of Rated Airflow RATED CFM 110 120 O1 Unitary Products Group 295421 YTG B 0707 EXTENDED AIR FLOW DATA F4FV VARIABLE SPEED MODELS CFM TAP SELECTION F4FV High Speed Cooling and Heat Pump CFM Jumper F4FV060H06T2 COOL TAP ADJ TAP 2100 1 Both the COOL and the ADJ tap must be set for the cooling CFM 2 Fan only CFM 63 of high speed cooling 3 Low speed cooling used only with two stage outdoor units Speed is preset to 65 of high speed 4 Dehumidification speed is 85 of cooling speed 5 When operating in both heat pump and electric heat modes the CFM will be whichever is greater 6 CFM indicator light flashes once for every 100 CFM i e 12 Flashes is 1200 CFM ELECTRIC HEAT CFM CFM Tap Selections HEAT ie F4FV060H06T2 1750 1420 DELAY PROFILE DELAY Tap Comfort Setting DE O ma DD Lo Tra Normal The normal setting provides a 30 second ramp up from zero airflow to full capacity and a 30 second ramp down from full capacity back to zero airflow Whenever there is a change in airflow mode such as a call for cooling or a change from low heat to high heat the motor will take 30 seconds to ramp from one speed to the other Humid The humid setting is best suited for installations where the humidity is frequently very high during cooling
10. ional Corp 2007 All rights reserved Supersedes 295421 YTG A 0507 Unitary 5005 Norman Products York OK Group Drive 73069
11. oducts Group 295421 YTG B 0707 Physical and Electrical Data MODEL FAFPOZ4HOSTE FA4FPOGOHOGT2 FAFPOUGHOGTE PROMOTE Biomer bemeerviih m m mo we e DR CEC A IC O sors sar ERC Fated 184 2582 oseo ema Locked Rotor s329 6265 7465 6255 Disposable Permanent see o o ia aa at OE A Sangre Weight bs com 0500 msi vans Me a n o do to to Nominal BPM 30 1050 1050 120 Futo 4458 soer me 76 7870 moo Disposable Permanent Shipping Operating Weight bs 1 Field Supplied ELECTRICAL DATA Cooling Only Minimum Circuit aa E Total Motor Total Motor Amps m Max O C P Amps Minimum Wire pac Size A W G e is 15 20 18 ER as as 02 28 Farrosemoste as 80 42 37 gt Farrocarosre E C ss ee wo From 81 ee 35 34 0 185 gt Eros 75 78 95 98 18 HO VARIABLE SPEED MODEL VARIABLE SPEED MODEL E A LALA AA Ico 1 O C P Over Current Protection device must be HACR type Circuit Breaker or Time Delay Fuse Unitary Products Group 7 295421 YTG B 0707 ELECTRICAL DATA 19 208 230 1 60 MAX STATIC Total Heat KW Staging Model amp MIN CFM KW MBH WiOny W2Ony Wi w Static Tap 208v 240v 208V 240v 208v 240v 208v 240v 208v 240V FAFPOZ4HOST2 os 75 T E 33 tow 255 F4FPO36H06T2 0 E ic 5 130771138 O
12. rements for proper Heat Pump operation 1 Includes Return Air Filter and Largest Electric Heater All F FP series air handler units are UL Listed up to 0 50 w c external static pressure including air filter wet coil and largest KW size heater 4 Unitary Products Group 295421 YTG B 0707 EXTENDED AIR FLOW DATA FOR 208 VOLT HEAT PUMP MODELS 208 Volt CFM O External Static Pressure IWC DO MO Eemal Static Pressure WE O ojo om 050 040 oso 06 070 j os 080 100 A o ue ias os A on o os ass om om rosto hon op ires om oe a a im tam sr ias ros oo oer tons eia oro 666 a mas om ros os os or or raio iw 765 oe s o sei AAA AAA A io im ou 0 7 tow 61 mo on 1 655 lou sor ves nor os 1066 1054 1008 ose 009 tow e ves 1168 1086 oes 1009 oes dor ea NOTE Air flow data shown above 0 50 W C external static pressure is for REFERENCE ONLY Maximum allowable external static when electric heat is used is limited to 0 50 W C Maximum allowable external static pressure may also be limited by minimum CFM requirements for proper Heat Pump operation Blower Motor Speed 962 445 328 300 640 528 595 408 S Zr N 80 Rh 171 1724 1655 1587 N k O NO 1 Includes Return Air Filter and Largest Electric Heater All F FP series air handler units are UL Listed up to 0 50 w c external static pressure inclu
13. s designed to be used with all sizes of fan coil units whenever the application requires vertical suspension of the unit 295421 YTG B 0707 LIMITATIONS These units must be wired and installed in accordance with all national and local safety codes Voltage limits are as fol lows Normal Operating voltage Range 187 253 ELECTRIC HEATERS Models shown under Electrical Data 1 Utilization range A in accordance with ARI Std 110 include sequencers and temperature dual limit switches for safe efficient operation Circuit breakers are provided where shown BOLT ON THERMAL EXPANSION VALVE TXV kits are available for enhanced efficiency These fan coil units have factory installed TXV s Air flow must be within the minimum and maximum limits approved for electric heat evaporator coils and outdoor units Entering Air Temperature Limits Wet Bulb Temp F ai Bulb Temp F Min EXTENDED AIRFLOW DATA FOR 230 VOLT HEAT PUMP MODELS 230 Volt CFM O External Static Pressure IWC Blower Motor d DE om om 05 04 05 080 f 07 08 os pio Ms 90 MO 865 85 75 70 682 880 502 00 FarPozaHosT2 Mee 65 765 785 705 65 506 52 409 54 a 005 05 000 5 FO 1270 17210 1 60 17085 17015 998 882 769 65 502 F4FP030H06T2 64 Mes 1050 1060 005 9 655 eoa 714 626 40 306 e es seo vo vs oo II Far LHO 1250 1175 1720 1058 985 894 79
14. ual YORK Heating and Air Conditioning TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING amp HEAT PUMPS HEAT PUMP MODELS F FP VARIABLE SPEED MODEL F FV 4 C U L U L 9000 REGS ISO 9001 Certified Quality Management System Due to continuous product improvement specifications are subject to change without notice Visit us on the web at www york com Additional rating information can be found at www ari org aridirectory 295421 YTG B 0707 DESCRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal application These versatile models may be used for split system cooling or heat pump operation Compact cabinets along with return air options in both the upflow and horizontal positions allow this unit to fit into tight spaces such as attics crawl spaces and closets NOTE For matching condensing units and performance data refer to condenser technical guides FEATURES CABINET The compact and sturdy cabinet is protected with a durable attractive finish to prevent rust The cabinet is also insulated to prevent cabinet sweating F FP and F FV mod els have 3 4 inch insulation BLOWERS Blowers are sized to circulate air both quietly and efficiently The direct drive multi speed motors provide a selection of air volume to match any application Motor speeds may be selected via quick connect terminal at the motor Slide out blo
15. wer motor assemblies provide for easy servicing COILS Using the latest in heat transfer technology the rifled tube coil aluminum fin coils produce high performance ratings and provide long lasting quality The coils are capable of bot tom return air in the upflow position and right or left end return air in the horizontal position FACTORY INSTALLED TXV Air handler models F FP and F FV have factory installed TXV metering device ELECTRIC HEATERS Models providing up to 25kw of heat are available as field installed accessories Electric heaters are available in both single and three phase EASY INSTALLATION These fan coil units are designed to provide the lowest total installation cost Accessible color coded control wiring top and side power wiring knockouts easy to install drain connections and electric heaters all com bine to minimize installed cost on every job CONTROL BOARD The control board is equipped with low voltage terminal strips for easy installation The control board is also equipped with plug in receptacles for the auxiliary heaters FOR DISTRIBUTION USE ONLY NOT TO BE USED AT POINT OF RETAIL SALE DIMENSIONS SHIPPING BRACKET REMOVE PRIOR TO INSTALLATION 2 SCREWS DRAIN CONNECTIONS FOR HORIZONTAL APPLICATIONS VAPOR OPENING LIQUID OPENING DRAIN CONNECTIONS FOR UPFLOW APPLICATIONS 295421 YTG B 0707 ALL DIMENSIONS ARE IN INCHES THEY ARE SUBJECT TO CHANGE WITHOUT NOTICE CERTIFIED