Home
Yamaha Ri8-D/Ro8-D Update Manual
Contents
1. dialog box will be displayed NOTE The User Account Control dialog box may appear Click Continue or Yes If the Local Area Connection properties dialog box appears skip ahead to step 4 3 Click Properties The Local Area Connection properties dialog box will be displayed NOTE The User Account Control dialog box may appear Click Continue or Yes 4 Select Internet Protocol Version 4 TCP IPv4 then click Properties The Internet Protocol Version 4 TCP IPv4 Protocol dialog box will be displayed 5 Click Obtain an IP address automatically fc Internet Protocol Version 4 TCP IPv4 Properties A General Alternate Configuration You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings 5 Use the following IP address Obtain DNS server address automatically Use the following DNS server addresses 6 Click OK 10 EM Updating the Dante firmware Described below are the procedures to update the Dante module firmware integrated in the Ri Ro unit NOTE For details of the Dante Firmware Update Manager refer to AUD MAN Firmware Update Manager stored in the compressed file folder l Connect the Dante PRIMARY connector on the rear panel of the Ri Ro unit to the Ethernet connector on the computer using an Ethernet cable
2. Be sure to directly connect the computer and the Ri Ro unit and do not connect any other Dante device to the computer PRIMARY SECONDARY 2 Pull the dip switches 4 and 8 on the Ri Ro unit front panel down ON with the other switches remaining in their up positions OFP Turn on the power to the Ri Ro Select StartI gt All programs Audinate gt Dante Firmware Update Manager Dante Firmware Update Manager then right click and select Run as Administrator The Dante Firmware Update Manager will start up Check that the version number is 1 3 2 or higher from the title bar NOTE The User Account Control dialog box may appear Click Continue or Yes If you see the interface selection screen select the interface card to connect the Dante device Click Update Dante Firmware 11 7 Click Browse and select FWUpdate_Ri8 D vxxx swyyy dnt in case of Ri8 D or FWUpdate_Ro8 D vxxx swyyy dnt in case of Ro8 D Then click Open xxx and yyy represent the firmware version number NOTE The Dante firmware does not operate normally if its path contains any multi byte character including Japanese characters If you use a directory name containing any multi byte character in your computer store the firmware update files in a directory that consists only of ASCII characters e g C temp IN CAUTION Be sure to ensure compatibility of the update files with Ri Ro If update files other th
3. YAMAHA Ri8 D Ro8 D Firmware Update Guide Thank you for choosing a Yamaha product This guide explains how to update the Ri Ro Ri8 D and Ro8 D firmware and its built in Dante module firmware MW Precautions Please be sure to read this section first The user assumes full responsibility for the update Update the firmware components one unit at a time Please note that the device may be damaged if you fail to follow these instructions properly or turn off the device or disconnect the cable while the update is in progress If the update fails and the device still does not operate correctly even after you execute the update once again please contact your Yamaha dealer Yamaha Corporation owns exclusive copyrights for the Ri Ro firmware its update program and the update guide Audinate owns exclusive copyrights for the Dante firmware and its update program It is prohibited to duplicate or modify the firmware software or guides in part or in their entirety without permission from the copyright owner The screen shots in this guide are for use with this update procedure only and may be different from the actual screen shots Dante is a registered trademark of Audinate Windows is a registered trademark of Microsoft Corporation in the United States and other countries The company names and product names in this document are the trademarks or registered trademarks of their respective companies EM Checking the version nu
4. power 6 Connect the Dante PRIMARY connector on the rear panel of the Ri Ro unit to the Ethernet connector on the computer using an Ethernet cable PRIMARY SECONDARY 7 8 10 11 12 Pull the dip switches 4 and 8 on the Ri Ro unit front panel down ON and turn the power on with the other switches remaining in their up positions OFF The right side of the SYSTEM indicator and the SYNC indicator start flashing and the unit is activated in update mode Double click updatev2 exel The R Series Update Program V2 will start up Make sure that the fields in the File section indicate as follows file name RISROS_PROG bin product name R Series Version Version number to which the firmware will be updated FR Series Update Program V2 Ea TOP port 12302 IP address 192 168 0 2 firmware a File file name RIRO8_PROG BIN product name R Series version v2 00 Connect and Update connection product name version update NOTE The User Account Control dialog box may appear Click Continue or Yes Click the Connection button in the Connect and Update column The product name field will display R Series and the version field will display the version number of the Ri Ro firmware NOTE i If these fields are empty your computer may not be properly connected to the Ri Ro Please make sure that the cable is not disconnecte
5. program Download the latest program from the following URL http www yamahaproaudio com downloads NW Update procedure sequence Update each firmware component in the following sequence To update more than one Ri Ro unit configure Computer TCP IP setting for Ri Ro unit and perform Updating the Ri Ro firmware one by one Then configure Computer TCP IP setting for Dante and perform Dante firmware update one by one Install the Dante Firmware Update Manager o e Computer TCP IP setting for Ri Ro unit Updating the Ri Ro firmware Computer TCP IP setting for Dante Updating the Dante firmware If there are 2 computers you may use one for Ri Ro unit firmware update and the other for Dante firmware update so that you can perform the work without switching the TCP IP settings To update more than one Ri Ro firmware application it is recommended to use 2 computers for the update E Install the Dante Firmware Update Manager Before you update the Dante firmware you must install the Dante Firmware Update Manager Double click the Dante Firmware Update Manager installer downloaded in Preparing for the update DanteFirmwareUpdateManager x x x exe and follow the on screen instructions to install the firmware x x x represents the version number of the Dante Firmware Update Manager In addition extract the Dante firmware extension dn
6. that you wish to proceed Click OK to start the recovery Firmware Update Manager will display Processing Safe Recovery and then Safe recovery Done when the device s are recovered Exit the Dante Firmware Update Manager and wait for two minutes before turning off the power to the Ri Ro unit The correct Dante firmware now needs to be loaded Follow steps 2 through 11 described in Updating the Dante firmware Now recovery and firmware update are completed 15 E Error Message List R Series Update Program V2 Error messages that consist of an error number and a string in English for the R Series Update Program V2 may be displayed on the computer This section explains the error numbers the English strings and the appropriate action to take NOTE Ifthe same error message appears each time you try to update the device may need repairing in which case you ERROR 101 ERROR 107 ERROR 009 ERROR 108 ERROR 109 should contact your Yamaha dealer ERROR 001 ERROR 006 An error occurred while communicating with the device The Ri Ro is not engaged in Update mode Information on the Ri Ro could not be obtained Make sure that the computer is connected to the Ri Ro correctly then restart the R Series Update Program V2 and the Ri Ro unit 2P 7 After turning the Ri Ro power off pull the dip switches 4 and 8 down ON and put all other switches OFF and then turn
7. Ro firmware Before you start updating the firmware decompress the downloaded compressed file Place RI8RO8_PROG bin updatev2 exe and update ini in the same folder NOTE For information about messages displayed by the Ri Ro firmware update program refer to Error Message List R Series Update Program V2 at the end of this guide Before starting the update program quit all other programs While the update is in progress do not start any other programs or switch between windows If your computer enters Sleep or Energy Save mode data transfer to the device may stop Therefore you should disable these functions to prevent this from happening We also recommend that you do not use any screen saver or similar background programs 1 Turn off the power to the Ri Ro 2 Take note of the dip switch settings on the Ri Ro unit front panel Follow the procedure below to change dip switch settings Take note of the original dip switch settings in order to restore the settings when the Dante firmware update is completed 3 Disconnect the Ethernet cable from the Dante PRIMARY connector and SECONDARY connector on the rear panel of the Ri Ro unit 4 Pull the dip switch 4 on the Ri Ro unit front panel down ON and turn the power on with the other switches remaining in their up positions OFF 5 After the orange SYNC indicator flashes twice periodically on the front panel of the Ri Ro unit turn off the
8. amaha Ro8 D 060460 Ro8 D B ad METER CL I O DEVICE screen r Dante Controller Device View Y000 Yamaha Ro8 D 06093c File Device Help A SR 59 oe 000 Yamaha Ro8 D 06093c y Status Device Config Network Config Device Information Manufacturer Yamaha Corporation Product Type Ro8 D Product Version 1 50 0 Software Version 1 1 0 Firmware Version 1 1 0 Dante Information Mo L Software Version 3 6 4 20 irmware Vers Glock Synchronisation Status Master External Word Glock No Preferred No Frequency Offset 0 ppb Primary Interface Dante Controller Device View IP Address 169 254 172 29 MAC Address 00 1D 01 06 09 30 Tx Utilisation 18 KBps Errors 0 Rx Utilisation 10 KBps Errors 0 Preparing for the update You will need the following items ready to execute the update procedure O A Windows computer equipped with the following conditions OS Windows 8 8 1 Pro Windows 7 Ultimate Professional Home Premium CPU Intel Pentium 1 2GHz or Intel Celeron 1 7GHz or higher HDD 250MB or more Connector An Ethernet connector that supports a data transfer rate of 100Mbps or higher O An Ethernet cable CAT5e or higher recommended Straight or cross O The Ri Ro firmware Download the latest firmware from the following URL http www yamahaproaudio com downloads The Dante firmware update
9. an Ri Ro are applied the device will become inoperable In general do not check the Override Device Matching option If this option is left unchecked only devices that support the file can be selected ensuring that updating the device with invalid or wrong files is prevented 8 Click Next NOTE Dante Firmware Update Manager may be blocked by the Windows Firewall Select the Private Network checkbox and click Allow access 9 Check the Ri Ro to update Check the version of the update files and the version number indicated in the Ri Ro line _ Dante Firmware Update Manager v1 3 2 ee Audinate Firmware Update Manager 1 matching devices found of 1 total Upload File FWUpdate_Ro8 D_v36420_sw110 v3 6 4 for Yamaha Corporation Ro8 D select All Name Manufacturer Model Version IP Statu Y000 Yamaha Ro8 D 01 Yamaha Corporation Ro8 D 3 6 4 1169 254 172 29 Ready Back Refresh Start A NOTE If the Ri Ro is not indicated click Refresh If it is still not indicated after that the computer and the Ri Ro are not connected properly Check that the cable is not loose or disconnected TCP IP is properly configured and the Ri Ro is activated with the correct dip switch settings 10 Click Start The update operation will begin Updating n m appears in the Status field during updating Done is displayed once update is completed IN CAUTION Update takes 2 to 4 minutes During th
10. d or damaged that the TCP IP settings are correct and that the Ri Ro has started in Update mode Click the Update button in the Connect and Update column The update operation will begin A CAUTION The update will take about 30 seconds During the update operation do not turn off the power to the unit or disconnect the cable If update fails due to disconnection of the power cable during the update or due to other reasons the device may become inoperative When the Connect and Update section displays the message Update was completed Close this Update Program click the X button in the upper right corner of the program window to close the program Turn off the power to Ri Ro EM Computer TCP IP setting for Dante To update Dante firmware configure computer TCP IP settings 1 Open the Network and Sharing Center as described below Windows 7 Select Start Control Panell then click or double click Network and Sharing Center or View network status and tasks Windows 8 and Windows 8 1 Windows X Control Panell then click or double click Network and Sharing Center or View network status and tasks The Network and Sharing Center is displayed 2 Click Manage network connection or Change Adapter settings from the Tasks list located in the left side of Network and Sharing Center window then double click Local Area Connection The Local Area Connection Status
11. e update operation do not turn off the power to the unit or disconnect the cable If update fails due to disconnection of the power cable during the update or due to other reasons the device may become inoperative NOTE If update is not completed after 5 minutes or update failure indication appears click X at the upper right corner of Dante Firmware Update Manager to exit the program without turning the Ri Ro power off and restart the procedure from the step 4 If update still fails follow the instructions stated in About Failsafe Mode to perform the recovery process 12 11 Turn off the power to the Ri Ro and return the dip switches to their original settings Please return the dip switch settings to the positions noted in step 2 of the Updating the Ri Ro firmware The firmware update is now complete 13 E About Failsafe Mode During normal operation software must be loaded from a flash memory drive during operations to use the Dante module integrated in the Ri Ro However data in a flash memory drive may occasionally become corrupted as with any other storage device In many cases such data corruption is caused by turning the Ri Ro power off during firmware upgrading The Dante module has a specially protected flash drive section in order to recover from such a condition When the main section is damaged the program stored in the protected area is activated and the Dante module goes into failsafe mode To
12. mber You may check the Ri Ro main firmware version number from the firmware update program R Series Update Program V2 or the Dante Controller of Audinate 7 ER Series Update Program V2 TOP port 12302 IP address 192 168 0 2 firmware a e File file name RISROS_PROG BIN product name R Series version w2 00 Connect and Update product name R Series version Connection was completed R Series Update Program V2 Al connection update Dante Controller Device View Y000 Yamaha Ro8 D 06093c File Device Help 000 Yamaha Ro8 D 06093c 1 I Status Device Contig I Network Config Device Information SR 3 De Manufacturer Yamaha Corporation oftware Version Firmware Version 1 1 0 r Dante Information Model Bklyn2 Software Version 3 6 4 20 Firmware Version 3 4 3 8 Glock Synchronisation Status Master External Word Clock No Preferred No Frequency Offset 0 ppb rPrimary Interface m i IP Address 169 254 172 29 MAC Address 00 1D G1 06 09 3C Tx Utilisation 18 KBps Errors 0 gt Rx Utilisation 10 KBps Errors 0 Dante Controller Device View You may check the Dante firmware version number from the I O DEVICE screen of CL series or Dante Firmware Update Manager of Audinate 1 0 DEVICE a2 az Rio3724 0 _ CH4 ch 4 16 45 20 FOMIN era To ni N AMP EXTERNAL i HA DANTE SETUP V001 Y
13. ox will be displayed NOTE The User Account Control dialog box may appear Click Continue or Yes If the Local Area Connection properties dialog box appears skip ahead to step 4 3 Click Properties The Local Area Connection properties dialog box will be displayed NOTE The User Account Control dialog box may appear Click Continue or Yes 4 Select Internet Protocol Version 4 TCP IPv4 then click Properties The Internet Protocol Version 4 TCP IPv4 Protocol dialog box will be displayed 5 Click Use the following IP address 6 Enter your computer s IP address 192 168 0 101 into IP address and 255 255 255 0 into Subnet mask Internet Protocol Version 4 TCP IPv4 Properties La JE General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 0 101 Subnet mask 255 255 255 0 Default gateway Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server Validate settings upon exit A NOTE l If you specify other values for the IP address you will be unable to update Ri Ro firmware 5 7 Click OK EM Updating the Ri Ro firmware This section explains how to update the Ri
14. restore a Dante module in failsafe mode a recovery image needs to be sent from the Firmware Update Manager To check if the Dante module is in failsafe mode use Dante Controller the respective device is displayed in red in the network grid view of the Dante Controller version 3 1 x or higher Furthermore the red SYSTEM indicator on the Ri Ro unit will periodically flash twice Described below are the procedures to recover the Dante module integrated in the Ri Ro unit 1 Turn off the power to the computer and the Ri Ro 2 Separate the Ri Ro from the Dante network 3 Connect the Dante PRIMARY connector on the rear panel of the Ri Ro unit to the Ethernet connector on the computer using an Ethernet cable PRIMARY SECONDARY 4 Turn the computer power on and logon to Windows with administrative privileges 5 Turn on the power to the Ri Ro 6 Disable all but one of the network interfaces on your computer 14 Select StartI gt All programs gt Audinatel gt Dante Firmware Update Manager gt Dante Firmware Update Manager then right click and select Run as Administrator The Dante Firmware Update Manager will start up NOTE The User Account Control dialog box may appear Click Continue or Yes If you see the interface selection screen select the interface card to connect the Dante device Click Failsafe Recovery Check the detected Ri Ro Click Start A pop up is displayed confirming
15. t from the compressed file The Dante firmware does not operate normally ifits path contains any multi byte character including Japanese characters If you use a directory name containing any multi byte character in your computer store the firmware update files in a directory that consists only of ASCII characters e g C temp NOTE The Windows Security dialog box may appear In such case click Install this driver software anyway You may be prompted to restart the computer after the installation is complete Before proceeding to update restart the computer When installing the Dante Firmware Update Manager temporarily disable any running anti virus software EM Computer TCP IP setting for Ri Ro unit To update Ri Ro unit firmware configure computer TCP IP settings 1 Open the Network and Sharing Center as described below Windows 7 Select Start gt Control Panell then click or double click Network and Sharing Center or View network status and tasks Windows 8 and Windows 8 1 Windows X Control Panell then click or double click Network and Sharing Center or View network status and tasks The Network and Sharing Center is displayed 2 Click Manage network connection or Change Adapter settings from the Tasks list located in the left side of Network and Sharing Center window then double click Local Area Connection The Local Area Connection Status dialog b
16. the power on gt P 7 The device may need repairing in which case you should contact your Yamaha dealer ERROR 111 The firmware data file was not found Place the RISRO8_PROG bin file in the folder that contains the updatev2 exe file gt P 7 16 C S G PA Development Division O 2013 2014 Yamaha Corporation co
Download Pdf Manuals
Related Search
Related Contents
Scosche KA2090B car kit Bericht der Bundesregierung über den Stand von Sicherheit Kendall SCD™ Symmons 353TP Instructions / Assembly Keil Software Fall 1999 Newsletter Avision IS25 TRST-A10 - Owners Manual V1.2 - 2007-03-13 Copyright © All rights reserved.
Failed to retrieve file