Home

Yamaha PW3000M Owner's Manual

image

Contents

1. YAMAHA PWSOODOM POWER SUPPLY Owner s Manual Mode d emploi Bedienungsanleitung FCC INFORMATION U S A 1 IMPORTANT NOTICE DO NOT MODIFY THIS UNIT This product when installed as indicated in the instructions contained in this manual meets FCC requirements Modifications not expressly approved by Yamaha may void your authority granted by the FCC to use the product IMPORTANT When connecting this product to accessories and or another product use only high quality shielded cables Cable s supplied with this product MUST be used Follow all installation instructions Failure to follow instructions could void your FCC authorization to use this product in the USA NOTE This product has been tested and found to comply with the requirements listed in FCC Regulations Part 15 for Class B digital devices Compliance with these requirements provides a reasonable level of assurance that your use of this product in a residential environment will not result in harmful interference with other electronic devices This equipment generates uses radio frequencies and if not installed and used according to the instructions found in the users manual may cause interference harmful to the operation of other electronic devices Compliance with FCC regulations does not guarantee that interference will not occur in all installations If this product is found to be the source of interference which can be determined by turning the unit OFF an
2. metal objects on top of the power supply unit M etal objects inside the power supply unit area fire and electrical shock hazard Do not block the power supply unit ventilation slots The power supply unit has ventilation slots at the front to prevent the internal temperature from rising Blocked ventilation slots area fire hazard Leave a reasonable amount of free air space around the power supply unit If the power supply unit is to be rack mounted leave at least 10 cm free above the top panel and behind the rear panel When the power supply unit isin use remove the rear of the rack or open its ventilation slots to prevent overheating which could beafire hazard e e e e e e Do not try to modify the power supply unit This could bea fire and electrical shock hazard The power supply unit operating temperature is between 5 C and 35 C 41 F and 95 F Turn off all audio devices and speakers when connect ing to the power supply unit Refer to the owner s manual for each device Use the correct cables and connect as specified If you notice any abnormality such as smoke odor or noise turn off the power supply unit immediately Remove the power cord from theAC outlet Confirm that the abnormality is no longer present Consult your dealer for repair Using the power supply unit in this condition is a fire and shock hazard If a foreign object or water gets inside the power sup ply unit turn it off
3. of the power supply will go dark Turn the power off and wait for atime before turning the power on again If the same LED s are dark contact a Yamaha service center C GND terminals Thisis the grounding screw terminal If hum or noise occurs ground earth the unit via this jack or try connecting it to the chassis of the other device D DC OUTPUT connector Connect this connector to the M 3000 to supply power to it POWER SUPPLY DC PARALLEL INPUT connector This connector allows two PW 3000M units to be con nected in parallel As shown in the following diagram use the included parallel connection cable to make connections In this case thetwo PW 3000M unitswill each supply 50 of the power in normal operation Even in the unlikely event that one of the PW 3000M units failed the other PW3000M will supply 100 of the power ensuring an uninterrupted power supply DC POWER INPUT DC PARALLEL INPUT PW3000M DC OUTPUT Specifications Power Requirements USA and Canada 120 V 60 Hz Europe 230 V 50 Hz Others 240 V 50 Hz Power Consumptions USA and Canada 400 W 540 VA Europe 380 W Others 380 W Dimension W x H x D 480mm x 103 5mm x 455mm Weight 15kg mPower supply cable pin configuration Pin No Power supply remote Signal name 15V 15 V GND 48 V GND 15V 12 V 12V GND power supply remot
4. the terminal which is marked with the letter N or coloured BLACK The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED This applies only to products distributed by YAMAHA KEMBLE MUSIC U K LTD MPrecautions e e e e e e e e e Connect the power supply power cord only to an AC outlet of the type stated in this Owner s M anual or as marked on the power supply unit Failureto do soisa fire and electrical shock hazard Do not locate the power supply unit in a place subject to excessive heat or in direct sunlight This could bea fire hazard Do not place the power supply unit in a place subject to excessive humidity or dust This could bea fire and electrical shock hazard Do not plug several devices into the same AC outlet This may overload the AC outlet and could bea fire and electrical shock hazard It may also affect the per formance of some equipment Do not place heavy objects on the power cord A dam aged power cord isa potential fire and electrical shock hazard If the power cord is damaged i e cut or a bare wireis exposed ask your dealer for a replacement Using the power supply unit in this condition isa fire and shock hazard Hold the power cord plug when disconnecting from an AC outlet Never pull the cord Damaging the power cord in this way is a potential fire and electrical shock hazard Do not place small
5. d ON please try to eliminate the problem by using one of the following measures Relocate either this product or the device that is being affected by the interference Utilize power outlets that are on different branch circuit breaker or fuse circuits or install AC line filter s In the case of radio or TV interference relocate reorient the antenna If the antenna lead in is 300 ohm ribbon lead change the lead in to coaxial type cable If these corrective measures do not produce satisfactory results please contact the local retailer authorized to distribute this type of product If you can not locate the appropriate retailer please contact Yamaha Corporation of America Electronic Service Division 6600 Orangethorpe Ave Buena Park CA 90620 The above statements apply ONLY to those products distributed by Yamaha Corporation of America or its subsidiaries WARNING THIS APPARATUS MUST BE EARTHED IMPORTANT THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE GREEN AND YELLOW EARTH BLUE NEUTRAL BROWN LIVE As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured GREEN and YELLOW must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or coloured GREEN and YELLOW The wire which is coloured BLUE must be connected to
6. e Power supply remote oJoIiNI OD oa AJOJN 48 V oO FRAME GND Dimensions Power supply connector DC PARALLEL INPUT 405 6 D 455 Specifications and appearance are subject to change without notice for improvement 308 49 4 DC OUTPUT 292 56 8 _ Units mm
7. immediately Renove the power cord from theAC outlet Consult your dealer for repair Using the power supply unit in this condition is a fire and electrical shock hazard If you plan not to use the power supply unit for along period of time remove the power cord from the AC outlet Leaving the power supply unit connected isa fire hazard Do not use benzene thinner cleaning detergent or a chemical cloth to clean the power supply unit Use only asoft dry cloth The power supply unit uses high frequency digital cir cuits that may cause interference on radios and televi sions placed close to it If interference does occur relocate the affected equipment Front panel YAMAHA OPERATION MONITOR 48V_ 12V 15V_ 15V O O 0 0 NORMAL m ON OFF DC PARALLEL INPUT PWSOOOM DC OUTPUT CONNECT PIN 2 15V 4 20 DISCONNECT The PW 3000M power supply should be installed in a well ventilated location In particular the front and rear panels must not be blocked since the ventilation path passes through them A POWER ON OFF switch After connections to the M 3000 have been completed turn this switch on to supply power to the M 3000 B Operation monitor Four LEDs indicate the status of the power that is being supplied to the M 3000 Normally i e when no malfunction has occurred the green LEDs NOR MAL will light If a malfunction occurs the LED for that section

Download Pdf Manuals

image

Related Search

Related Contents

Terraillon SAS France 8. Headquarîers  巡警告  GPRS Tau User Manual En - Inova  2096  GR-D346E - JVC Europe  STM32 ST-LINK Utility software description  NEC MultiSync LCD2180UX, Black  