1. Parts List To order any of the following items contact your authorized WYBRON dealer The PS Power Supplies POND ner PS 150 20300 a ii PS 300 20600 aan PS 600 The PS Mounting and Installation Accessories PISO tr a aa PS 150 PS 300 and PS 600 hanger bracket SCERWGE252075 2 un n nn Wing screw for power supply hanger bracket to pipe SERSGCZEZUDST ni Socket cap screw for hanger bracket to power supply Power Data Cable 7042 3 RER 3 power signal cable POA Dr Os edn det aside ates net en 5 power signal cable LOAD Wen et nea ah eins a 10 power signal cable TOA 15 ea 15 power signal cable A ec muse 25 power signal cable 1042 50 ent 50 power signal cable POMPES PO Ne ee I er 75 power signal cable 1042 100 ei ant ana nes 100 power signal cable 15 Warranty Information WYBRON INC warrants to the original owner or retail customer that for a period of one year from date of delivery of a portable system or energization of a permanently installed system up to a maximum of 18 months from delivery its products will be free from defects in materials and workmanship under normal use and service Warranty does not cover any product or part of a product subject to accident negligence alteration abuse misuse or any accessories or parts not supplied by WYBRON INC Warranty does not cover consumable parts such as fuses lamps or color media WYBRON INC s warranty does not extend to items not manufactured by us F
2. 300 watts 600 watts Quantity per Power Supply y y y Max Description Model Head Feal PS 150 PS 300 PS 600 NexeraLX tungsten a 1500 8 16 32 NexeraLX CDM 2580 2600 1500 6 12 24 Forerunner 4 inch 4540 n a 16 32 64 Forerunner 7 inch 7140 n a 16 32 64 The above information assumes devices are on different channels and all move simultaneously 9 Installing Connecting the Power Supply To get your Power Supply up and running follow these hookup and checkout procedures 1 Mount the power supply The Power Supply is designed to be free standing truss mounted or rack mounted The power supply comes with a mounting bracket which hooks over the pipe or truss of your lighting rig and is then locked into place with a thumb screw If you have selected this mounting method connect the power supply s safety cable by clipping it around the pipe or truss The power supply can also be mounted into a 19 rack using the optional rack mount kit The rack mount kit will accommodate two power supplies side by side 2 Connect the device to the power supply Connect the device to the power supply using a 4 pin Wybron Power Data cable Refer to the HEAD FEET RESTRICTION section of the manual for details of the length of cable runs Note The Wybron Power Data Cable has been specially designed to minimize voltage drop use only Wybron supplied cable 3 Connect the Power Supply to AC power Plug t
3. The twisted pair shield is connected at male XLR connector end only XLR Pin Wire Color Function Size 1 White Ground 14 AWG 2 Green Data 22 AWG 3 Red Data 22 AWG 4 Black 24VDC 14 AWG DMX512 Control Cable The DMX control cable from the lighting console to the power supply is a five conductor cable with 5 pin XLR connectors on each end The wiring pin out is specified by the USITT DMX512 1990 standard XLR Pin Function 1 Common 2 Data 3 Data 4 Talkback 5 Talkback Specifications PS 150 PS 300 and PS 600 Power Supply Connectors DMX in Male 5 pin XLR DMX out Female 5 pin XLR Output Female 4 pin XLR DMX512 termination None DMX signal pass thru Fuse PS 150 model 20150 Input voltage 100 240V 50 60 Hz 3 1 5A 250V 2A Slo Blo for 100 120V 250V 1A Slo Blo for 220 240V PS 300 model 20300 Input voltage 100 240V 50 60 Hz 5 3A 250V 4A Slo Blo for 100 120V 250V 2A Slo Blo for 220 240V PS 600 model 20600 Input voltage 100 240V 50 60 Hz 10 5A 250V 7A Slo Blo for 100 120V 250V 4A Slo Blo for 220 240V Input Power Automatically accepts 100 240V 50 60 Hz Input Signal 1990 USITT standard DMX512 Red LED Indicates power Green LED Indicates DMX signal Size PS 150 12 7 323mm L x 7 6 193mm W x 2 9 74mm H Weight 3 9 Ibs 1 8 kg PS 300 14 356mm L x 7 8 198mm W x 3 76mm H Weight 5 4 Ibs 2 4 kg PS 600 14 356mm L x 7 8 198mm W x 4 1 104mm H Weight 7 9 Ibs 3 6 kg
4. alternatif est utilis e comme le principal d branche l appareil S assurer que la douille sortie localise install pr s de l quipement et est facilement accessible LES AVANCES PRINCIPAUX SONT CONFORMEMENT COLORES AU CODE SUIVANT ET DOIVENT ETRE CONNECTES DANS L ARRANGEMENT SUIVANT gt vert et jaune terre gt bleu neutre gt marron ligne L AVERTISSEMENT CET EQUIPEMENT DOIT ETRE FONDE Pour les questions Wybron de contact 1 800 624 0146 ou visite www wybron com L Avertissement de Modification de Produit Les produits de Wybron Inc sont con us et a fabriqu pour rencontrer les conditions d Etats Unis et de norms de s ret internationals Les modifications aux produits pourraient affecter la s rete et rendent le produit non conciliant aux normes de s rete pertinentes Aviso Sobre Seguridad SALVE ESTAS INSTRUCCIONES LEA Y SIGA TODAS INSTRUCCIONES Este manual da el paso por paso las instrucciones para la preparaci n para arreglo y para la operaci n de la PS fuente del poder Hay un riesgo potencial del fuego el calambre o la herida a personas si el producto no se utiliza como instruido ADVERTENCIA Cuando se usa electrodom sticos el uso las precauciones b sicas incluyendo e Lea este manual antes de accionar o instalar la instalaci n fija e Supervise a ni os cercano e Seque ubicaci n s lo La PS fuente del poder deber ser utilizado en un ambiente interior s lo y no es pensado
5. para el uso residencial Para la protecci n continuada contra el riesgo del fuego reemplaza s lo con mismo tipo y calificaci n de fusible La Protecci n contra calambre se asegura s lo si el conjunto conectado principal de cuerda es conectado a un apropiadamente earthed que muele recept culo de tipo Una toda asta desconecta dispositivo se debe localizar adyacente a la unidad o si la cuerda de C A se utiliza como el principal desconecta dispositivo asegure que la enchufe salida localiza instalado cerca del equipo y sea f cilmente accesible EL PRINCIPAL DIRIGE SON COLORADOS DE ACUERDO CON EL CODIGO SIGUIENTE Y se DEBE CONECTAR EN EL ESQUEMA SIGUIENTE gt verde y amarillo moli la tierra gt azul neutral gt brown linea La ADVERTENCIA ESTE EQUIPO DEBE SER EARTHED Para preguntas el contacto Wybron en 1 800 624 0146 o visita www wybron com Advertencia de Modificaci n de Producto Wybron los productos S a se dise an y son fabricados para encontrar los requisitos de Estados Unidos y est ndares Internacionales de seguridad Las modificaciones a los productos podr an afectar la seguridad y rendir el producto no conformista a est ndares pertinentes de seguridad Sicherheitshinweise BEHALTEN SIE DIESEN ANWEISUNGEN LESEN SIE UND GEHORCHEN SIE ALLEN ANWEISUNGEN Dieses Handbuch gibt Schritt f r Schritt Anweisungen zur Vorbereitung Aufstellung und Funktion dem PS Quelle der Kraft Es gibt ein potenz
6. E WARNING THIS EQUIPMENT MUST BE EARTHED For questions contact Wybron at 1 800 624 0146 or visit www wybron com Product Modification Warning Wybron Inc products are designed and manufactured to meet the requirements of United States and International safety standards Modifications to the products could affect safety and render the product non compliant to relevant safety standards Notes de Securite EPARGNER CES INSTRUCTIONS LIRE ET SUIVRE TOUTES INSTRUCTIONS Ce manuel donne des instructions pour la preparation l organisation et l op ration du le PS provision d lectricit Il y a un risqu de feu d charge lectrique ou la blessure aux gens si le produit n est pas utilize comme instruit AVERTISSEMENT En utilisant des appareils lectriques utilise la prudence fondamentale inclut e Lire ce manuel avant d alimenter ou l installation de l accessoire e Utiliser la prudence pr s des enfants S cher l emplacement seulement Le PS provision d lectricit va tre utilize la maison seulement et pas pour l usage residential Pour la protection continu e contre le risque de feu remplacer seulement avec le m me type et le m me classement de fusible La Protection contre la d charge lectrique est seulement assur e si la s rie de corde connect e principale est connect e un convenablement terre de type Un appareil d branchant doit tre localis c t de l unit ou si la corde de courant
7. PS 150 PS 300 PS 600 Power Supplies User Manual ADVANCINGTHEARTOFLIGHTING PS 150 Model 20150 150 watts PS 300 Model 20300 300 watts PS 600 Model 20600 600 watts Software version 1 0 Manual revision March 15 2006 CONTENTS Declaration of Conformity nenn 3 Safety Information neren 4 IHFOQUELON ea Rs 8 System Components vers nd 8 PS Power opi 8 Compatible Devices nn 8 Power Data Cable nennen 9 System Layout DiagraM ooooooooccccccccccccccccconnnnncnnnnnncnnnnnnns 9 Equipment Compatibility aaa id 9 Installing Connecting the Power Supply 10 Head Feet Restrictions rrenen 10 Mounting and Installation Accessories 11 Cables saine detente eee 13 Specifications LL A a 14 PANS Es ae 15 Warranty Informations Ark tante aie 16 Ce DECLARATION OF CONFORMITY Manufacturers Name Wybron Inc Manufacturers Address 4830 List Dr Colorado Springs Colorado 80919 USA Equipment Name PS 600 PS 300 and PS 150 Power Supply Equipment Model Numbers 20600 20300 and 20150 This product is in conformity with the following standards Referenced Safety Standard s Referenced EMC Standard s EN60598 1 EN55022 EN60598 2 17 EN61000 following the provisions of the EU LV Directive 73 23 EEC and the EU EMC Directive 89 336 EEC decla
8. aussetzungen von Vereinigten Staaten und Internationalen Sicherheitsstandards zu erf llen nderungen zu den Produkten k nnten Sicherheit beeinflussen und k nnten das Produkt leisten das verordnungswidrig ist zu relevanten Sicherheitsstandards 7 Introduction The PS 150 PS 300 and PS 600 are Wybron s new RDM compatible Power Supplies The power supplies work with their compatible devices allowing you to control the fan speed where applicable via one or multiple DMX channels on the lighting console Plus the compact power supplies attach easily to the truss of the lighting rig or mount into a 19 inch rack System Components Power Supply The power supply passes the DMX512 signal level from the lighting console and then sends to each device along with 24 volts DC The DMX512 control signal from the lighting board is connected to the power supply and can continue on to more power supplies or other DMX controlled devices The power supply sends both power and control signal on a single cable eliminating the need for a separate power cable for each device attached Caution The PS Power Supply is currently only compatible with A Forerunner and NexeraLX DO NOT connect PS Power Supplies to RAM Coloramil devices Coloramll CXI Goboramll or Eclipse and DO NOT connect Forerunner or NexeraLX to RAM Coloram Il Power Supplies Damage from such action will not be covered by the equipment warranties Compatible Devices At the time o
9. f printing of this manual the PS 150 PS 300 and PS 600 Power Supplies are only for use with the following devices e Nexera LX e Forerunner color changers Refer to the Nexera LX or Forerunner user manuals for detailed operating information on these products More products will be compatible in the future To operate Forerunner The maximum amount of cable per power supply output is 350 feet The maximum number of color changers per power supply output is eight 8 Power Data Cable The Power Data Cable connects the Power Supply outputs to the connected devices and provides them with power and control signal The cable uses 4 pin XLR connectors on either end and consists of two 14 AWG conductors and a 22 AWG twisted shielded pair 8 AC Power Example of a system layout NexeraLX Forerunner PS oe Supply 0000 0000 DMX control console EP VEA CON LL LLE BL AMMAR UL SO DO sooo DO ODODOEDOCED DMX512 Equipment Compatibility The following is a chart of compatibility and capacity of the various models of PS Power Supplies and the companion devices This is current as of the print date of this manual As more products are added to the compatible line an updated list will be available on the Wybron website at www wybron com Power Supply PS 150 PS 300 PS 600 Model Number 20150 20300 20600 Output Power 150 watts
10. he AC cord into a non dimmed power circuit The power supply automatically accommodates 100 240V 50 60 Hz Caution Do not power the power supply from a dimmed circuit A Severe damage will result and is not covered by product warranty Power at the power supply is indicated by the red LED which can be viewed from the stage 4 Connect and set the DMX512 source Connect the DMX512 signal source to the DMX input connector on the front of the power supply using standard DMX cable The DMX signal will be indicated by a flashing green LED The DMX signal will now position the gelstrings vanes according to their respective DMX signal levels Head Feet Restrictions The HEAD FEET parameter is a method of accounting for the voltage drop in the power signal cable caused by the current drawn by each device To help understand this issue think of it as water pressure voltage in a hose cable where you have multiple water sprinkler heads color changers If the hose cable is too long or you have too many sprinkler heads color changers the water pressure voltage will be too low HEAD FEET is defined as the sum of cable lengths from each device to a single power supply output Refer to the user manual of the specific components for detailed head feet information on those products Mounting and Installation Accessories The following sections describe the procedures for installation and replacement of mounting accessories P
11. ielles Risiko des Feuers Elektroschocks oder Verletzung zu Personen wenn das Produkt nicht benutzt ist als unterrichtet ist WARNUNG Beim Benutzen elektrischer Ger te Gebrauch grundlegende Vorsichtsma nahmen einschlie lich e Lesen Sie dieses Handbuch vor Betreiben oder Installieren des Inventar e Benutzen Sie Aufsicht nahe Kinder e Trocken Sie Ort nur Der PS Quelle der Kraft soll in einer Hallenumwelt nur benutzt werden und ist f r Heimumwelt nicht vorgehabt F r fortgesetzten Schutz gegen Risiko des Feuers ersetzt nur mit gleichem Typ und Bewertung der Sicherung Schutz gegen Elektroschock ist nur gezusichert wenn die Hauptleitungen Schnursatz verbunden haben ist an eine ordentlich earthed Erdung von Beh lter angeschlossen Eine alle Stange schaltet Vorrichtung muss sich befunden werden neben der Einheit ab oder Wenn die AC Schnur benutzt ist w hrend die Hauptleitung Vorrichtung abschaltet Sichert dass der Steckdosensteckdose ist befunden nahe die Ausr stungen installieren und ist leicht zug nglich DIE HAUPTLEITUNGEN BLEIE SIND GEM SS DEM FOLGENDEN CODE GEF RBT UND M SSEN IM FOLGENDEN SCHEMA VERBUNDEN WERDEN gt Gr n und Gelb Erden Sie Erde gt Blau neutral gt Braun linie WARNUNG DIESE AUSR STUNGEN MUSS EARTHED WERDEN F r Fragen Kontakt Wybron an 1 800 624 0146 oder besucht www wybron com Produkt nderungswarnung Wybron Inc Produkte sind entworfen und sind hergestellt die Vor
12. ntended as a complete and exclusive statement of the terms thereof Prior dealings or trade usage shall not be relevant to modify explain or vary this warranty Acceptance of or acquiescing in a course of performance under this warranty shall not modify the meaning of this agreement even though either party has knowledge of the performance and a chance to object ieh ADVANCING HEARTOFLIGHTING WYBRON INC TEL 719 548 9774 FAX 719 548 0432 Email info wybron com Visit us on the World Wide Web at http www wybron com 16
13. ower Supply hanger brackets The power supplies are shipped with hanger brackets to allow pipe or truss mounting Follow these steps to install the hanger bracket 1 Disconnect AC power from the power supply 2 Place the power supply on its side on a flat surface 3 Position the brackets as shown on the next page 4 Attach the bracket using a 3 16 Allen wrench and the supplied screws 11 Note Use the supplied thumb screws to clamp the hanger brackets to the desired pipe or truss Power Supply Hanger Brack Power supply rack mounting The rack mount accessory can be used with up to two power supplies and allows them to be mounted into a 19 inch rack Follow these steps to install the power supply into the rack mounting tray 1 Disconnect AC power from the power supply 2 Place the rack mount tray right side up on a flat surface 3 Position the power supply in the rack mount tray as shown below 4 Attach the power supply to the rack mount tray using the supplied screws Note The cover plate may be removed to allow installation of a second power supply SCrews Rack Mount Tray 12 Cables Power Data Cable The Power Data Cable uses 4 pin XLR connectors on either end and consists of two 14 AWG conductors and a 22 AWG twisted shielded pair The shells of the two XLR connectors are not electrically connected together this prevents large power currents from flowing from chassis to chassis of the equipment
14. re that the equipment specified above conforms to the above Directive s and Standard s Signature a AB Aare Printed Name _ ay FASE 3 30303030303 Title YA Ok ENG Date 208 Safety Information SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS This manual gives step by step instructions for the preparation setup and operation of the PS 150 PS 300 and PS 600 Power Supply There is a potential risk of fire electric shock or injury to persons if the product is not used as instructed WARNING When using electrical appliances use basic precautions including e Read this manual before connecting power e Use supervision around children e Use in a dry location only The PS Power Supply is to be used in an indoor environment only and is not intended for residential use For continued protection against risk of fire replace only with same type and rating of fuse Protection against electric shock is assured only if the mains connected power supply cord set is connected to a properly earthed grounding type receptacle An all pole disconnect device must be located adjacent to the unit or if the AC cord is used as the main disconnect device ensure that the socket outlet is located installed near the equipment and is easily accessible THE MAINS LEADS ARE COLORED IN ACCORDANCE WITH THE FOLLOWING CODE AND MUST BE CONNECTED IN THE FOLLOWING SCHEME GREEN AND YELLOW EARTH BLUE NEUTRAL BROWN LIN
15. reight terms on warranty repairs are FOB WYBRON INC factory or designated repair facility Collect shipments or freight allowances will not be accepted WYBRON INC s sole responsibility under this warranty shall be to repair or replace at WYBRON INC s option such parts as shall be determined to be defected on WYBRON INC s inspection WYBRON INC will not assume any responsibility for any labor expended or materials used to repair any equipment without WYBRON INC s prior written authorization WYBRON INC shall not be responsible for any incidental general or consequential damages to property damages for loss of use time profits or income or any other charges The owner s obligations during the warranty period under this warranty are to notify WYBRON INC at WYBRON INC s address within one week of any suspected defect and return the goods prepaid to WYBRON INC at their factory or authorized service center This warranty is contingent on the customer s full and timely compliance with the terms of payment set forth in said purchase order This warranty is expressly in lieu of any and all other warranties expressed or implied including the warranties of merchantability and fitness for a particular purpose and of other obligations and liabilities on our part The owner acknowledges that no other representations were made to him or relied upon him with respect to the quality and function of the goods sold This written warranty is i