Home

Wayne GPB400 User's Manual

image

Contents

1. Numero de Serie de haberlo 101 Production Drive Descripci n y n mero del repuesto Harrison OH 45030 como se indica Art culo N Descripci n N mero de pieza 1 Motor 57800 001 1 2 Montaje del espiral 56724 001 1 3 Juego de impulsor 56711 1 4 Tornillo 17046 001 1 5 Chaveta 16997 001 1 6 Kit del sello del eje 56711 1 7 Espiral 56723 001 1 8 Tap n del tubo de 1 9 cm 3 4 pulg NPT 15921 2 9 Junta del difusor 15556 002 1 10 Tornillo de sombrerete 5 16 18 x 1 12701 5 11 Tornillo de sombrerete 5 16 24 x 7 8 16209 4 12 Arandela de presi n separada 5 16 no se muestra 15916 4 13 Mango 56722 001 1 14 Base 11007 001 1 18 Sp GPB400 Notas 19 Sp Instrucciones de funcionamiento y Lista de piezas de repuesto GPB400 Garantia limitada Durante un 1 a o a partir de la fecha de compra WAYNE Water Systems WAYNE Pumps reparar o reemplazar a su criterio para el comprador original cualquier pieza o piezas de sus Bombas para cloacas o Bombas de agua el Producto que despu s de un examen sea n hallada s por WAYNE Pumps como defectuosa s en su material o mano de obra S rvase llamar a WAYNE Pumps 800 237 0987 para obtener instrucciones o consulte a su distribuidor Est listo para proporcionar el n mero de modelo cuando ejerza el derecho a esta garant a Todos los gastos de transporte de los product
2. www waynepumps com Operating Instructions and Replacement Parts List GPB400 Limited Warranty For one year from date of purchase WAYNE Water Systems WAYNE Pumps will repair or replace at its option for the original purchaser any part or parts of its Sump Pumps or Water Pumps Product found upon examination by WAYNE Pumps to be defective in materials or workmanship Please call WAYNE Pumps 800 237 0987 for instructions or see your dealer Be prepared to provide the model number when exercising this warranty All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser This Limited Warranty does not cover Products which have been damaged as a result of accident abuse misuse neglect improper installation improper maintenance or failure to operate in accordance with WAYNE Pumps written instructions THERE IS NO OTHER EXPRESS WARRANTY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to you This limited warranty gives you specific legal rights and yo
3. COURBE DE RENDEMENT T te Dynamique Totale PIED 0 1200 2400 3600 4800 6000 7200 Capacit GPH 11 Fr Mode d emploi et Liste de Pi ces de Rechange Pour Pi ces de Rechange ou Assistance Technique appeler 1 800 237 0987 Veuillez fournir l information suivante Adresser la correspondance Num ro de mod le WAYNE Water Systems Num ro de s rie s il y a lieu 101 Production Drive Description et num ro de pi ces tel Harrison OH 45030 qu indiqu Article num ro Description Num ro de pi ce 1 Moteur 57800 001 1 2 Support de volute 56724 001 1 3 Trousse d impulseur 56711 1 4 Vis 17046 001 1 5 Cl 16997 001 1 6 Trousse de garniture d tanch it de l arbre 56711 1 7 Volute 56723 001 1 8 Bouchon de tuyau 3 4 po NPT 15921 2 9 Joint d tanch it volute 15556 002 1 10 Vis t te hexagonale 7 9 mm 5 16 po 18 x 1 12701 5 11 Vis t te hexagonale 7 9 mm 5 16 po 24 x 2 2 mm 7 8 po 16209 4 12 Rondelle frein 7 9 mm 5 16 po avec coupure pas indiqu 15916 4 13 Poign e 56722 001 1 14 Base 11007 001 1 12 Fr GPB400 Remarques 13 Fr Mode d emploi et Liste de Pi ces de Rechange GPB400 Garantie limit e Pendant un an compter de la date d achat WAYNE Water System WAYNE Pumps r parera ou remplacera sa discr tion pour l acheteur original toute pi ce ou pi
4. FEET 0 1200 2400 3600 4800 6000 7200 Capacity GPH www waynepumps com Operating Instructions and Replacement Parts List For Replacement Parts or Technical Assistance call 1 800 237 0987 Please provide following information Address parts correspondence to Model number WAYNE Water Systems Serial number if any 101 Production Drive Part description and number as shown Harrison OH 45030 Item No Description Part Number Qty 1 Engine 57800 001 1 2 Volute Bracket 56724 001 1 3 Impeller kit 56711 1 4 Screw 17046 001 1 5 Key 16997 001 1 6 Shaft seal kit 56711 1 7 Volute 56723 001 1 8 Pipe plug 3 4 NPT 15921 2 9 Volute gasket 15556 002 1 10 Cap screw 5 16 18 x 1 12701 5 11 Cap screw 5 16 24 x 7 8 16209 4 12 Lock washer split 5 16 not shown 15916 4 13 Handle 56722 001 1 14 Base 11007 001 1 www waynepumps com GPB400 Notes www waynepumps com Operating Instructions and Replacement Parts List Maintenance Service Record Date Maintenance Performed Replacement Components Required www waynepumps com GPB400 Maintenance Service Record Date Maintenance Performed Replacement Components Required
5. niveau atteigne approximativement 7 6 mm 3 po partir du sommet Installer le bouchon de remplissage L eau dans la pompe provoquera l aspiration qui amorce la pompe PORT D AMOR AGE D CHARGE APPIRATION Figure 3 PORT DU DRAIN 10 Mettre le robinet carburant en position ON marche 11 Passer le levier de l trangleur en position CHOKE trangleur 12 Passer le commutateur de moteur en position ON marche 13 Tirer sur la manette de d marrage jusqu ce que le moteur d marre Une fois que le moteur d marre passer le levier de l trangleur en position RUN marche 14 La pompe s amorcera en quelques minutes TUYAUTERIE Toujours placer la pompe aussi pr s que possible de l eau pomper Maintenir tous les tuyaux et les canalisations aussi courts et droits que possible Supporter la pompe et WARNING la tuyauterie pendant l assemblage et apr s installation Le non respect de cette consigne PEUT entra ner la rupture du tuyau ou la panne de la pompe etc ce qui peut r sulter en d g ts mat riels etlou en blessures personnelles Tous les raccordements de la conduite d aspiration doivent tre tanches Si la pompe ne s amorce pas v rifier les fuites dans le tuyau d aspiration ou au niveau des raccords Si un tuyau d aspiration flexible est utilis au lieu d un tuyau utiliser un tuyau renforc de 5 1 cm 2 po de diam tre int rieur Les tuyaux non
6. fico de aceite y la cantidad necesaria 8 Llene el tanque del motor con gasolina Consulte el manual de funcionamiento del motor para ver el tipo de gasolina espec fico que sea m s eficiente para este motor 9 Agregue agua en el puerto de cebado en la bomba vea la Figura 3 Contin e agregando agua hasta que el nivel de agua est aproximadamente a 7 6 cm 3 pulg del borde Instale el tap n de cebado El agua en la bomba crear la succi n que ceba la bomba Figura 2 4 Se necesita un filtro de succi n para filtrar el material abrasivo Los materiales abrasivos como la grava destruir n la bomba y anular n la garant a Esta bomba no est dise ada para manipular materiales abrasivos 5 La manguera y las conexiones de descarga deben ser herm ticas Una fuga en la manguera de descarga har que se roc e agua en el sitio de trabajo lo cual es peligroso 6 Mantenga todas las tuber as y mangueras tan cortas y rectas como sea posible Las grandes longitudes y curvas en las tuber as y mangueras reducir n la presi n que crea la bomba PUERTO DE CEBADO DESCARGA SUCCI N PUERTO DE DRENAJE Figura 3 10 Gire la v lvula de combustible a la posici n de encendido ON 11 Mueva la palanca de toma de aire a la posici n CHOKE toma de aire 12 Mueva el interruptor del motor hacia la posici n ON 13 Tire de la manivela del motor hasta que el motor arranqu
7. renforc s peuvent se replier partir du vide cr alors que la pompe s amorce Toujours utiliser un tamis l extr mit du tuyau d aspiration ou du tuyau Positionner le tamis de mani re ce qu il ne soit pas bouch par des pierres ou des d bris Une conduite d aspiration avec clapet de non retour est recommand e NE PAS utiliser cette pompe pour des hauteurs d aspiration de plus de 7 6 m 25 pi Entretien Toujours teindre le moteur laisser le moteur refroidir et retirer la bougie avant tout entretien Durant les p riodes de gel ouvrir le port du drain et laisser l eau dans la pompe se drainer Cela emp chera d endommager la pompe quand l eau est gel e Si la pompe est ranger pour un mois ou plus drainer l eau de la pompe et suivre les recommandations du fabricant du moteur pour le stockage long terme 10 Fr GPB400 Informations sur le Rendement Performance de la pompe en fonte 5 cm 2 po CAPACIT S EN GALLONS PAR HEURE D charge E T te Pied Aspiration Dynamique Pied 10 15 20 6600 6420 6180 6000 5640 5220 30 6180 6000 5640 5220 4800 4380 40 5640 5220 4800 4380 4080 3660 50 4800 4380 4080 3660 3300 2820 60 4080 3660 3300 2820 2400 1800 70 3300 2820 2400 1800 1260 720 80 2400 1800 1260 720 0 0 PERTE DE FRICTION EN PIEDS DANS 30 5 M 100 PI DE TUYAU EN PLASTIQUE Taille du RE u mus tuyau 20 un 1 1 2 4 0 5 5 9 4 14 3 19 9 34 2
8. suite d une rupture de contrat de garantie acte dommageable y compris la n gligence ou autre ni WAYNE Pumps ni ses fournisseurs ne seront responsables de tout dommage sp cial cons cutif indirect ou punitif y compris mais sans s y limiter la perte de profits ou recettes la perte d usage des produits ou de tout quipement associ dommage l quipement associ co t de capital co t de produits de remplacement am nagements services ou capacit de remplacement co t de temps que le produit n est pas en service ou la r clamation des clients de l acheteur pour ces dommages Il faut conserver le re u d achat ainsi que ce formulaire S il FAUT pr senter une r clamation de garantie il FAUT envoyer une COPIE du re u d achat en plus du mat riel ou de la correspondance Veuillez appeler WAYNE 800 237 0987 pour l autorisation et instructions concernant le renvoi NE PAS POSTER CE FORMULAIRE WAYNE PUMPS Utiliser ce formulaire seulement pour vos archives NUM RO DU MOD LE NUM RO DE S RIE DATE D INSTALLATION ATTACHER LE RE U ICI 14 Fr Instrucciones de funcionamiento y Lista de piezas de repuesto GPB400 Sirvase leer y guardar estas instrucciones Lea atentamente antes de intentar armar instalar operar o realizar mantenimiento al producto descrito Prot jase a usted mismo y a otros respetando toda la informaci n de seguridad No respetar las instrucciones podria dar como resultado lesiones personale
9. Operating Instructions and Replacement Parts List GPB400 Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury andlor property damage Retain instructions for future reference WAYNE Engine Driven Centrifugal Pump Description The WAYNE pumps are general use centrifugal water pumps The pump is equipped with EPDM seals that are intended for water use only Safety Guidelines This manual contains information that is very important to know and understand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the following symbols Danger indicates an DANGER imminently hazardous situation which if NOT avoided WILL result in death or serious injury Warning indicates a WARNING potentially hazardous situation which if NOT avoided COULD result in death or serious injury Caution indicates a CAUTION potentially minor or moderate injury if NOT avoided MAY result in serious injury Notice indicates NOTICE important information that if NOT followed MAY cause damage to equipment General Safety Information CALIFORNIA PROPOSITION 65 This product may WARNING contain chemicals known to
10. ameter Non reinforced flexible hose may collapse from the vacuum created as the pump primes Always use a strainer at the end of the suction pipe or hose Position strainer so it doesn t become clogged with stones or debris A suction line check valve is recommended Do NOT use this pump for suction lifts over twenty five feet Maintenance Always shut off the engine allow the engine to cool and remove the spark plug before performing any maintenance During freezing weather open the drain port and allow all the water in the pump to drain This will prevent damage to the pump when the water freezes If the pump will be stored for a month or more drain the water from the pump and follow the engine manufacturer s recommendations for long term storage www waynepumps com GPB400 Performance Information 2 Cast Iron Pump Performance CAPACITIES IN GALLONS PER HOUR Discharge Dynamic Suction Lift Feet Head Feet 10 15 20 6600 6420 6180 6000 5640 5220 30 6180 6000 5640 5220 4800 4380 40 5640 5220 4800 4380 4080 3660 50 4800 4380 4080 3660 3300 2820 60 4080 3660 3300 2820 2400 1800 70 3300 2820 2400 1800 1260 720 80 2400 1800 1260 720 0 0 FEET FRICTION LOSS IN 100 FEET OF PLASTIC PIPE Gallons Per Minute 40 50 60 1 1 4 5 6 8 5 11 9 20 2 30 5 1 1 2 2 6 4 0 5 5 9 4 14 3 19 9 34 2 2 1 2 1 6 2 8 4 2 5 8 9 9 15 0 21 2 2 1 2 1 2 1 8 2 5 4 2 6 3 8 8 PERFORMANCE CURVE Total Dynamic Head
11. biens Conserver les consignes pour s y r f rer l avenir Pompe Centrifuge WAYNE a Moteur Description Les pompes WAYNE sont g n ralement utilis es pour les pompes eau centrifuges La pompe est quip e de joints d tanch it con us uniquement pour une utilisation dans l eau Directives de s curit Ce manuel contient de l information tr s importante conna tre et comprendre Cette information est fournie pour LA S CURIT et pour PR VENIR LES PROBL MES D QUIPEMENT Pour aider reconna tre cette information consulter les symboles suivants A DANGER Danger indique une situation dangereuse imminente qui MENERA la mort ou a des blessures graves si elle n est pas vit e Avertissement WARNING indique une situation potentiellement dangereuse qui si elle n est pas vit e RISQUE d entra ner des l sions corporelles graves ou m me la mort Attention indique CAUTION de potentielles l sions corporelles mineures ou mod r es qui si elles ne sont pas vit es pourraient entra ner des blessures graves Notice indique une NOTICE information importante qui pourrait endommager l quipement si elle N est PAS respect e Information g n rale sur la s curit PROPOSITION 65 DE LA CALIFORNIE WARNING Ce produit peut contenir des produits chimiques reconnus dans l tat de Californie comme cause de cancer d an
12. ces de ces pompes de puisard ou pompes eau Produit d termin es d fectueuses par WAYNE Pumps en terme de mat riaux ou de fabrication Veuillez appeler WAYNE Pumps 800 237 0987 pour obtenir des instructions ou communiquer avec votre marchand S assurer de pouvoir fournir le num ro du mod le afin d exercer cette garantie Tous les frais de transport des Produits ou des pi ces soumises pour la r paration ou le remplacement sont la responsabilit de l acheteur Cette Garantie Limit e ne couvre pas les produits endommag s suite un accident mauvais traitement mauvais usage n gligence installation incorrecte entretien incorrect ou un fonctionnement non conforme aux instructions crites de WAYNE Pumps IL N Y A AUCUNE GARANTIE EXPRESSE LES GARANTIES IMPLICITES Y COMPRIS CELLES QUI INDIQUENT SI LE PRODUIT EST VENDABLE OU CONVENABLE UN USAGE PARTICULIER SONT LIMIT ES UN AN COMPTER DE LA DATE D ACHAT CECI EST LE SEUL RECOURS ET TOUTE RESPONSABILIT POUR TOUT DOMMAGE INDIRECT OU CONS CUTIF OU D PENSES QUELCONQUES EST EXCLUE Certaines Provinces n autorisent pas de limitations de dur e pour les garanties implicites ni l exclusion ni la limitation des dommages fortuits ou indirects Les limitations pr c dentes peuvent donc ne pas s appliquer Cette garantie limit e vous donne des droits l gaux pr cis et vous pouvez avoir d autres droits l gaux qui varient d une juridiction l autre En aucun cas soit par
13. congelamiento abra el puerto de drenaje y permita que se drene toda el agua de la bomba Esto evitar que la bomba se da e cuando el agua se congele Si va a guardar la bomba durante un mes o m s drene el agua de la bomba y siga las recomendaciones del fabricante del motor para almacenamiento a largo plazo 16 Sp GPB400 Informaci n del rendimiento Desempe o de la bomba de hierro fundido de 5 cm 2 pulg CAPACIDADES EN GALONES POR HORA Altura de Altura de succi n din mica en pies descarga en pies 10 15 20 20 6600 6420 6180 6000 5640 5220 30 6180 6000 5640 5220 4800 4380 40 5640 5220 4800 4380 4080 3660 50 4800 4380 4080 3660 3300 2820 60 4080 3660 3300 2820 2400 1800 70 3300 2820 2400 1800 1260 720 80 2400 1800 1260 720 0 0 PERDIDA POR ROZAMIENTO EN 30 48 M 100 PIES DE TUBERIA PLASTICA Tama o de la Galones por minuto tuberia 20 25 30 40 50 60 80 100 1 1 4 5 6 8 5 11 9 20 2 30 5 1 1 2 2 6 4 0 5 5 9 4 14 3 19 9 34 2 2 1 2 1 6 2 8 4 2 5 8 9 9 15 0 21 2 2 1 2 1 2 1 8 2 5 4 2 6 3 8 8 CURVA DE RENDIMIENTO Cabeza dinamica total en PIES 0 1200 2400 3600 4800 6000 7200 Capacidad GPH 17 Sp Instrucciones de funcionamiento y Lista de piezas de repuesto Para obtener piezas de repuesto o asistencia t cnica llame al 1 800 237 0987 Sirvase proporcionar la siguiente Dirija su correspondencia sobre informacion repuestos a Numero de modelo WAYNE Water Systems
14. e Una vez que el motor arranque mueva la palanca de la toma de aire a la posici n RUN funcionamiento 14 La bomba demorar varios minutos en cebarse TUBER AS La bomba debe colocarse lo m s cerca posible del agua a bombear Mantenga todas las tuber as y mangueras tan cortas y rectas como sea posible Sujete la bomba y la WARNING tuber a cuando la est ensamblando y despu s de la instalaci n El no hacerlo PODR A provocar que la tuber a se rompa que la bomba no funcione etc lo cual PUEDE resultar en da o a la propiedad ylo lesiones personales Todas las conexiones de succi n deben estar selladas herm ticamente Si la bomba no se ceba compruebe que no haya fugas en la tuber a ni conexiones de succi n Si se usan mangueras flexibles de succi n en lugar de tuber as use mangueras reforzadas con un di metro interno de 5 1 cm 2 pulg Las mangueras flexibles no reforzadas pueden colapsar por el vac o creado cuando la bomba se ceba Use siempre un filtro en el extremo de la tuber a o manguera de succi n Coloque el filtro de modo que no se obstruya por piedras ni residuos Se recomienda usar una v lvula de retenci n en la l nea de succi n NO use esta bomba para alturas de succi n mayores a 7 6 m 25 pies Mantenimiento Siempre apague el motor deje que el motor se enfr e y quite la buj a antes de realizar el mantenimiento En condiciones clim ticas de
15. e spark plug wire from the spark plug Complete pump and NOTICE Piping system MUST be protected against below freezing temperature Failure to do so COULD cause serious damage and WILL void the warranty 6 Do NOT run pump dry Water is required to lubricate the shaft seal 7 Pumping chemicals or corrosive liquids with this pump will shorten the life of the pump and may be hazardous to the operator and void the warranty 8 Personal Safety a Wear safety glasses at all times when working with pumps b Keep work area clean uncluttered and properly lighted replace all unused tools and equipment c Keep visitors at a safe distance from the work area d Make workshop child proof with padlocks master switches and by removing starter keys 9 This pump is designed for non abrasive fluid transfer do NOT use as a trash pump ALWAYS use a suction strainer with this pump to filter abrasive material Abrasive materials such as sand and gravel will shorten the life of the pump Installation This pump is designed to be self priming when installed and operated as specified below 1 The pump should be placed as close as possible to the water being pumped A pump with 20 foot suction lift will not remove water as quickly as a pump with 5 foot suction lift Figure 1 5 Ft SUCTION Figure 1 REMINDER Keep your dated proof of purchase for warranty purposes Attach i
16. illthe engine crankcase with oil Refer to the engine operating manual for the specific grade of oil and amount required 8 Fill the engine fuel tank with gasoline Refer to the engine operating manual for specific gasoline type that is most efficient for this engine 9 Add water to the priming port on the pump See Figure 3 Continue adding water until the water level is approximately 3 inches from the top Install the priming plug The water in the pump will create the suction that primes the pump PRIMING PORT DISCHARGE SUCTION Figure 3 DRAIN PORT 10 Turn fuel valve to ON position 11 Move choke lever to CHOKE position 12 Move the engine switch to ON position 13 Pull engine crank until engine starts Once engine starts move choke lever to RUN position 14 The pump will take several minutes to prime PIPING Always place the pump as close as possible to the water being pumped Keep all pipe and hose lines as short and straight as possible Support pump and A WARNING ing when assembling and after installation Failure to do so MAY cause piping to break pump to fail etc all of which CAN result in property damage andlor personal injury All suction connections must be airtight If the pump won t prime check for leaks in the suction piping or fittings If flexible suction hose is used instead of pipe use reinforced hose with a two inch inner di
17. is dans la conduite d aspiration pour maintenir la capacit d auto amor age Si le clapet de non retour n est pas utilis la pompe devra tre amorc e au d but de chaque utilisation Pour un meilleur fonctionnement le clapet de non retour doit tre install l entr e de la conduite d aspiration Figure 2 CLAPET Figure 2 4 Le tamis d aspiration est requis pour filtrer les mat riaux abrasifs Les mat riaux abrasifs tels que le gravier endommageront la pompe Ce qui rendra la garantie nulle Cette pompe n est pas con ue pour traiter les mat riaux abrasifs 5 Le tuyau de d charge et le raccord devraient tre herm tiques Une fuite dans le tuyau de d charge laissera l eau se r pandre sur l aire de travail rendant le site dangereux 6 Maintenir les tuyaux et les conduits aussi courts et droits que possible Les tuyaux et les conduits longs et courb s r duiront la pression d velopp e par la pompe 7 Remplir le carter du moteur avec de l huile Se reporter au manuel de fonctionnement du moteur pour conna tre le niveau sp cifique d huile et la quantit requise 8 Remplir le r servoir de carburant du moteur avec de l essence Se reporter au manuel de fonctionnement du moteur pour savoir quel type d essence sp cifique ce moteur est le plus efficace 9 Ajouter de l eau au port d amorgage de la pompe Voir Figure3 Continuer rajouter de l eau jusqu ce que le
18. isle el cable de la bujia desconectando el cable de la bujia de la misma Todo el sistema de la NOTICE bomba y la tuberia DEBE estar protegido contra temperaturas de congelamiento El no protegerlas PODRIA causar da os graves y ANULARA la garantia 6 NO haga funcionar la bomba sin liquido Se necesita agua para lubricar el sello del eje 7 El bombear productos qu micos o l quidos corrosivos con esta bomba puede acortar la vida til de la misma y puede ser peligroso para el operador y anular la garant a 8 Seguridad personal a Use gafas de seguridad en todo momento al trabajar con bombas b Mantenga el rea de trabajo limpia ordenada y bien iluminada ordene las herramientas y equipos que no utilice c Mantenga a los visitantes a una distancia segura del rea de trabajo d Haga del taller un lugar a prueba de ni os con candados e interruptores maestros y retire las llaves de arranque Esta bomba est dise ada para la transferencia de l quidos no abrasivos NO use como bomba para basura Use SIEMPRE un filtro de succi n con esta bomba para filtrar materiales abrasivos Los materiales abrasivos como la arena y la grava acortar n la vida til de la bomba Instalaci n Esta bomba est dise ada para cebarse autom ticamente cuando se instala y opera como se especifica a continuaci n 1 La bomba debe colocarse lo m s cerca posible del agua a bombear Una bomba co
19. la aplicaci n limitaciones y posibles riesgos de la bomba Lea estas reglas e instrucciones cuidadosamente El no seguirlas podria causar graves lesiones corporales y o da os a la propiedad NUNCA A DANGER ih funcionar el motor en un area cerrada Los gases de salida contienen monoxido de carbono t xico que puede ser mortal y que es insipido e inodoro WARNING 2 bombee fluidos inflamables o explosivos como gasolina gasoil queroseno etc NO use en atm sferas inflamables o explosivas Use la bomba SOLO con liquidos compatibles con los materiales de la bomba El no seguir esta advertencia PODRIA resultar en lesiones personales ylo danos a la propiedad 2 Cumpla con todas las precauciones de seguridad para el manejo del combustible NO Ilene el A WARNING 10 len de combustible con el motor caliente El combustible que se derrame sobre un motor caliente puede provocar un incendio o una explosion NO Ilene el tanque de combustible con el motor en funcionamiento 3 La bomba se deber colocar y apoyar sobre una base s lida y nivelada NO suspenda la bomba por medio de la tuberia de descarga Aseg rese de que la NOTICE bomba este sobre un buen apoyo para que no se caiga 4 NO use sopletes ni aplique calor en exceso fuego ni llamas en la bomba ya que esto puede provocar una explosion 5 Antes de trabajar en la unidad a
20. n una altura de succi n de 6 metros 20 pies no eliminar agua tan r pidamente como una bomba con una altura de succi n de 1 5 metros 5 pies Figura 1 0 ALTURA DE SUCCI N DE 6 m 20 PIES ALTURA DE SUCCI N Figura 1 RECORDATORIO Conserve su prueba de compra fechada para la garantia Adj ntela a este manual o archivela para conservarla de forma segura 2011 WAYNE Scott Fetzer Company 15 Sp 320605 001 8 11 Instrucciones de funcionamiento y Lista de piezas de repuesto Instalaci n cont 2 La manguera y las conexiones de succi n deben estar selladas herm ticamente Una fuga de aire en NOTICE la l nea de succi n PODR A impedir el cebado de la bomba Se recomienda el uso de un sellador de rosca Las l neas de succi n deben ser de manguera reforzada o tuber as r gidas Una manguera no reforzada colapsar debido a la succi n creada por la bomba e impedir que la misma funcione 3 Se debe usar una v lvula de retenci n en la l nea de succi n para mantener la capacidad de cebado autom tico Si no se usa una v lvula de retenci n se deber cebar la bomba cada vez que la haga funcionar Para el mejor funcionamiento la v lvula de contenci n debe instalarse a la entrada de la l nea de succi n Figura 2 7 Llene la caja del cig e al del motor con aceite Consulte el manual de funcionamiento del motor para ver el grado espec
21. omalies cong nitales ou d autres probl mes reproductifs Se laver les mains apr s toute manipulation 1 Conna tre l application les limites et les dangers possibles de la pompe Lire attentivement ces r gles et instructions Le non respect de ces instructions pourrait mener des blessures personnelles et ou des dommages la propri t NE JAMAIS A DANGER Bie fonctionner le moteur dans un espace ferm Les gaz qui s en chappent contiennent un poison mortel le monoxyde de carbone qui n a ni odeur ni go t WARNING VE PAS pomper de fluides inflammables ou explosifs tels que l essence le mazout le k ros ne etc NE PAS utiliser dans un milieu inflammable etlou explosif La pompe NE DEVRAIT TRE utilis e QU avec des liquides compatibles avec ses mat riaux composants Ne pas suivre cet avertissement PEUT mener des blessures et ou des dommages la propri t 2 Respecter toutes les pr cautions de s curit pour la manipulation du carburant Ne pas faire WARNING le plein dans un moteur chaud Renverser le carburant dans un moteur chaud pourrait causer un incendie ou une explosion Ne pas remplir un moteur en marche 3 La pompe doit tre install e et reposer sur une base solide et niveau NE PAS suspendre la pompe l aide du tuyau de d charge S assurer que la NOTICE pompe est fix e co
22. os o piezas enviadas para su reparaci n o reemplazo ser n a cargo del comprador Esta Garant a limitada no cubre Productos que est n da ados debido a accidentes abuso uso indebido negligencia instalaci n incorrecta mantenimiento inadecuado o no hacerlo funcionar seg n las instrucciones escritas de WAYNE Pumps NO HAY OTRAS GARANT AS EXPRESAS LAS GARANT AS IMPL CITAS INCLUYENDO AQUELLAS DE COMERCIABILIDAD E IDONEIDAD PARA UN USO ESPEC FICO SON LIMITADAS A UN A O A PARTIR DE LA FECHA DE COMPRA ESTE ES EL NICO RECURSO Y SE EXCLUYE CUALQUIER RESPONSABILIDAD POR TODO DA O DIRECTO O CONSECUENTE O POR CUALQUIER GASTO Ciertos estados no permiten limitaciones sobre el per odo de duraci n de las garant as impl citas ni permiten las exclusiones ni limitaciones de los da os incidentales o consecuentes de forma que las limitaciones mencionadas anteriormente pueden no aplicarse a usted Esta garant a limitada le otorga derechos legales espec ficos y tambi n puede tener otros derechos legales que pueden variar dependiendo del estado Bajo ning n concepto ya sea por incumplimiento del contrato de garant a incumplimiento extracontractual incluyendo negligencia u otro WAYNE Pumps o sus proveedores ser n responsables de ning n da o especial consecuente incidental o penal incluyendo pero sin limitarse a p rdida de ganancias p rdida de uso del producto o cualquier equipo asociado da os al equipo asociado costo de capi
23. rrectement sur un pied afin qu elle ne se renverse pas 4 NE PAS utiliser de chalumeau ou appliquer une chaleur excessive sur cette pompe car un incendie ou des flammes pourraient provoquer une explosion 5 Avant de travailler sur l appareil isoler le fil de la bougie en d branchant le fil de bougie de la bougie La pompe enti re NOTICE ainsi que le syst me de tuyauterie DOIVENT tre prot g s contre les temp ratures inf rieures au point de cong lation Le non respect de cette consigne POURRAIT causer de graves dommages et ANNULERA la garantie 6 NE PAS faire fonctionner la pompe sec Le joint d tanch it de l arbre doit tre lubrifi avec de l eau 7 Le pompage de produits chimiques ou de liquides corrosifs avec cette pompe r duira la dur e de vie de celle ci Cela peut tre dangereux pour l utilisateur et annuler la garantie 8 S curit personnelle a Porter des lunettes de s curit en tout temps en travaillant avec les pompes b Garder l aire de travail propre en ordre et bien clair e remplacer tous les outils et l quipement inutilis s c Garder les visiteurs distance sans danger du secteur de travail d S assurer que les ateliers sont s rs pour les enfants en utilisant des cadenas des interrupteurs centraux ou en retirant les cl s de d marrage 9 Cette pompe est con ue pour les transferts de fluides non abrasifs NE PAS utiliser comme
24. s ylo da o a la propiedad Conserve estas instrucciones para referencia futura Bomba centrifuga activada a motor WAYNE Descripci n Las bombas WAYNE son bombas centrifugas de agua de uso general La bomba est equipada con sellos EPDM que est n dise ados para uso nicamente con agua Guias de seguridad Este manual contiene informaci n que es muy importante que se conozca y comprenda Esta informacion es proporcionada por SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Para ayudar a reconocer esta informaci n observe los siguientes simbolos Peligro indica una DANGER situacion inminentemente peligrosa la cual si NO se evita TENDRA como resultado la muerte o una lesi n grave Advertencia indica WARNING una situacion potencialmente peligrosa la cual si NO se evita PODRIA RESULTAR en la muerte o una lesi n grave Precauci n indica CAUTION amp posibilidad de una lesi n menor o moderada la cual si NO se evita PODRIA resultar en una lesi n grave NOTICE Aviso indica informaci n importante que si NO se respeta PODRIA causar da o al equipo Informaci n general de seguridad PROPOSICION DE CALIFORNIA 65 Este producto WARNING puede contener productos quimicos conocidos por el Estado de California como causantes de cancer y defectos de nacimiento u otros da os reproductivos L vese las manos despues de manipularlo 1 Conozca
25. t to this manual or file it for safekeeping 2011 WAYNE Scott Fetzer Company For parts product amp service information visit www waynepumps com 320605 001 8 11 Operating Instructions and Replacement Parts List Installation continued 2 Suction hose and fitting must be airtight An air leak in the NOTICE suction line MAY prevent priming of the pump Use of thread sealant is recommended Suction lines must be reinforced hose or rigid pipe Non reinforced hose will collapse due to the suction created by the pump and prevent pump from operating 3 A check valve must be used in the suction line to maintain the self priming capability If no check valve is used the pump will need to be primed at the start of each operation For best operation the check valve should be installed at the intake of the suction line Figure 2 CHECK VALVE Figure 2 4 A suction strainer is required to filter abrasive material Abrasive material such as gravel will destroy the pump and void the warranty This pump is not designed to handle abrasive materials 5 The discharge hose and fitting should be leak tight A leak in the discharge hose will allow water to spray around the work site making the site hazardous 6 Keep all pipes and hose lines as short and straight as possible Long lengths and curves in the pipes and hose lines will reduce the pressure the pump develops 7 F
26. tal costo de productos sustitutos instalaciones poderes de servicio o reemplazo costos de inutilidad o reclamos de clientes del comprador por dichos da os Usted DEBE conservar su recibo de compra junto con este formulario En caso de tener que ejercer un reclamo de garant a DEBE enviar una COPIA del recibo de compra junto al material o correspondencia S rvase llamar a WAYNE Pumps 800 237 0987 para obtener autorizaciones e instrucciones de devoluci n NO ENV E ESTE FORMULARIO A WAYNE PUMPS Use este formulario s lo para mantener sus registros MODELO NO NO DE SERIE FECHA DE INSTALACI N SUJETE SU RECIBO AQU 20 Sp
27. the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling 1 Know the pump application limitations and potential hazards Read these rules and the instructions carefully Failure to follow them could cause serious bodily injury and or property damage NEVER run DANGER engine ih an enclosed area Exhaust gases contain deadly poisonous carbon monoxide which has no odor or taste AR Do NOT use A WARNING pump flammable or explosive fluids such as gasoline fuel oil kerosene etc Do NOT use in flammable and or explosive atmospheres Pump SHOULD only be used with liquids compatible with pump component materials Failure to follow this warning CAN result in personal injury andlor property damage 2 Observe all safety precautions for the handling of the fuel Do NOT A WARNING Poel hot engine Fuel spilled on a hot engine could result in a fire or explosion Do NOT refuel a running engine 3 Pump should be located and should rest on a level solid foundation Do NOT suspend pump by means of the discharge pipe Be sure pump is on secure footing so it NOTICE doesn t fall over 4 Do NOT use torches or apply excessive heat fire or flames to this pump as an explosion may result 5 Before working on the unit insulate the wire from the spark plug by disconnecting th
28. u may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall WAYNE Pumps or its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the products or any associated equipment damage to associated equipment cost of capital cost of substitute products facilities services or replacement power downtime costs or claims of buyer s customers for such damages You MUST retain your purchase receipt along with this form In the event you need to exercise a warranty claim you MUST send a COPY of the purchase receipt along with the material or correspondence Please call WAYNE Pumps 800 237 0987 for return authorization and instructions DO NOT MAIL THIS FORM TO WAYNE PUMPS Use this form only to maintain your records MODEL NO SERIAL NO INSTALLATION DATE ATTACH YOUR RECEIPT HERE www waynepumps com Mode d emploi et Liste de Pi ces de Rechange GPB400 Veuillez lire et conserver ces instructions Lire attentivement avant d assembler d installer de faire fonctionner ou de faire l entretien du produit d crit Se prot ger et prot ger les autres en observant tous les renseignements de s curit Le manquement se conformer aux consignes pourrait avoir pour r sultat des blessures corporelles etlou un endommagement des
29. une pompe ordures TOUJOURS utiliser un tamis d aspiration avec cette pompe pour filtrer les mat riaux abrasifs Les mat riaux abrasifs tels que le sable et le gravier r duiront la dur e de vie de la pompe Installation Cette pompe est con ue pour tre auto amorcable lors de l installation et durant son fonctionnement comme il est sp cifi ci apr s HAUTEUR D ASPIRATION DE 6 1 M 20 PIEDS 51m 15 pi ASPIRATION __ DER Figure 1 RAPPEL Garder la preuve d achat dat e aux fins de garantie La fixer ce manuel ou la ranger en lieu s r 2011 WAYNE Scott Fetzer Company 9 Fr 320605 001 8 11 Mode d emploi et Liste de Pi ces de Rechange Installation suite 1 La pompe doit tre plac e aussi pr s que possible de l eau pomper Une pompe d une hauteur d aspiration de 6 1 m 20 pi n aspirera pas l eau aussi vite qu une pompe d une hauteur d aspiration de 1 5 m 5 pi Figure 1 2 Letuyau d aspiration et le raccord doivent tre tanches Une fuite d air dans NOTICE la conduite d aspiration PEUT pr venir l amorcage de la pompe L utilisation d un ruban adh sif est recommand e Les conduites d aspiration doivent tre soit un tuyau renforc ou un tuyau rigide Le tuyau non renforc va se replier d l aspiration cr e par la pompe et emp cher celle ci de fonctionner 3 Un clapet de non retour doit tre util