Home
Vinotheque GCM-01 User's Manual
Contents
1. To adjust the doors and make sure they are flush with one another providing a tight seal These leveling legs are pre adjusted at our factory but they may need to be tweaked to fit your specific install location To level the unit slowly adjust the legs using the wrench Work in a clockwise motion to lengthen the leg or a counter clockwise motion to shorten it Do not try to level the cabinet with a leveling device The unit is designed to stand slightly off plumb tilting backward acutely so the doors will close firmly This will compensate for the weight of the doors Once you have completed leveling the cabinet check the unit to determine whether or not the doors are flush and sealing properly Customer Service 1 800 343 9463 shorten the leg Page 4 DOOR ALIGNMENT To assure the best performance from your Vinoth que wine cabinet the doors must seal properly in order to prevent cool air from escaping Check the alignment of the doors before filling it with bottles of wine The doors are aligned at the factory and no additional special door alignment is needed for Credenzas If adjustments are necessary compensate for this problem by adjusting the two front and or outside legs The high side of the cabinet should be adjusted down while the low side should be adjusted up Rock the unit side to side as it may aid the adjustment On single door units as you face the cabinet check to see if the door is highe
2. WARRANTY INFORMATION Labor For the period of two years from the date of purchase if the product is determined to be defective the manufacturer will repair or replace the unit at its option at no charge Parts Once it is determined that the unit is operating incorrectly the customer service department will issue an RMA Return Merchandise Authorization number This number must be included on the package of the returned cooling unit Cabinet integrity Remove the cooling unit from the cabinet by unscrewing the mounting screws located on the top and rear of the cabinet Warranty service To obtain warranty service you must make arrangements to have the unit shipped to the manufacturer s facility freight prepaid You must contact our Customer Service Department to receive a Return Merchandise Authorization number RMA and prepaid return tag Package the cooling unit in a well equipped box for necessary protection Mark the box with the return address and RMA number Items not covered under warranty e Removal and installation of cooling unit into the cabinet e Unauthorized repairs made on the unit Damage resulting from shipping e Inadequate ventilation on the exhaust side of the unit Constricted airflow to and from the unit e Insufficient power source to draw Internal clogged drain line For your convenience Vinoth que Wine Cellars has telephone numbers for frequently asked questions To locate the service facility
3. or Down arrow to change the set point Next press the Set button once and the set point numbers and the temperature on the display will blink to confirm the new set point 3 Press the Up button to display the high temperature data history or press the Down button to see the low temperature history Once the high low data history is displayed it can be reset by holding the set button RST will blink on the display It will then erase the past recorded data file and start recording from the current time and temperature 4 Press the Set and the Down buttons simultaneously for 3 to 5 seconds and you will access the customer preference selection menu The menu allows the customer to tweak the control system to their applicable choice To access the CPSM press the Set and Down buttons simultaneously for 5 7 seconds This will display CF now press the Set and Down buttons simultaneously for another 5 7 sec onds The display will briefly show Pr2 signifying you have accessed the CPSM The following CPSM options are available for adjustment Fon Humidity management This parameter is normally set at 5 which should provide adequate relative humidity for the cellar o An increase in this parameter will increase the humidity RH and a decrease in the parameter will decrease humidity o Adjustments should be made in increments of 5 with a maximum of 15 and a minimum of 0 oAfter any adju
4. cabinet with wine you ll want to check the operation of the unit All cabinets successfully pass quality control at the Vinoth que facility However periodically a unit s cooling system is damaged in transport Simply turn the unit on for about one hour and confirm that the temperature is cooling down This will prevent the inconvenience of stocking and restocking a damaged unit If the unit is not working correctly contact Vinoth que s customer service department at 800 343 9463 We will work with you to diagnose the problem and promptly resolve it LOADING BOTTLES 8 COOL DOWN PERIOD Loading bottles The cabinet may settle slightly based on the weight of all the bottles It is best to spread the loading of bottles evenly throughout the cabinet starting on the bottom first This will prevent the unit from shifting and potentially knocking the doors out of alignment In the QT Series there is a bulk area on the bottom for odd sized bottles In the WhisperKOOL series the bulk area is on top Cool down period When the time comes for you to begin loading wine bottles into your unit there are some considerations to be made The cabinet should be loaded in stages We recommend 1 4 of the cabinet per day This will allow the unit to achieve more rapid temperature stabilization Loading all of the wine at once might overwhelm the cooling system Set the switches as follows Thermostat 55 F or desired temperature Condensate evapora
5. or dealer nearest you for service assistance and resolution of a service problem or for product information and operation call Customer Service at 800 343 9463 Vinoth que Wine Cellars 1738 East Alpine Ave Stockton CA 95205 www vinotheque com Freight Freight for repairs will be limited to 90 days on the cabinet and one year on cooling units and parts Customer service Vinoth que is sold exclusively through a nationwide network of distributors These distributors are trained to be your primary resource for all customer service situations Through the sales process they have developed a thorough understanding of the environment the unit has been designed to operate within They are the best suited to address your individual needs and customized situation Customer Service 1 800 343 9463 Page 22 WARRANTY INFORMATION CONT Refrigeration referral services You can call Customer Service for refrigeration referral services 800 343 9463 In case repair is needed for refrigeration QT Series Contact Customer Service for refrigeration technician referrals in your area WhisperKOOL Series Either follow the directions for the QT Series or contact Customer Service and purchase a replacement unit under terms ofour Consumer Care program Page 23 GCM 01 050410 Vinoth que Wine Cellars 1738 E Alpine Ave Stockton CA 95205 800 393 9463 www vinotheque com
6. rack space Avoid pulling too much on the probe cord as it may become disconnected which would lead to inaccurate temperature readings The WhisperKOOL system is based on the temperature of the wine It is ideal to place the probed bottle lower in the racking so that it is not near cold supply air Customer Service 1 800 343 9463 Page 6 SYSTEM OPERATION WHISPERKOOL 2500 amp 1500 This section applies to cabinets equipped with the WhisperKOOL 1500 cooling system If your cabinet is equipped with a PDT or PDT Jr thermostat please refer to the next sections Initial start up When the unit is first turned on the control will briefly display all symbols and the green snowflake symbol will show up if the unit is calling for cooling There may be a brief delay prior to the evaporator fan turning on as it will not start until the probe temperature drops to below 70 F When the fan is activated the fan symbol will be displayed The Advance Product Safety Technology APST which ensures that in the possible event of a cooling deficiency the heat from the in cabinet fan will not raise the temperature of the wine cellar which could otherwise have an adverse effect on the wine aging process Normal system cycle After the bottle probe has reached the set point all units are shipped with the set point of 55 F and a differential of 1 degree the compressor and the condenser fan will turn off but the in cabinet evaporator fan wi
7. service This warranty is invalid if the factory applied serial number has been altered or removed from the product REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER VINOTH QUE SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ANY IMPLIED WARRANTY OF MERCHANTABILITY ORFITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY Customer Service 1 800 343 9463 Page 20 TESTING A RETURN UNIT CONT Some states do not allow the exclusion or limitation of incidental or consequential damages or allow limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you In addition if you enter into a service contract with The Convenience Series Partnership within 90 days of the date of sale the limitation on how long an implied warranty lasts does not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state The Convenience Series has established a Customer Service telephone number for frequently asked ques tions To locate a service technician or sales dealer in your area for service resolution assistance for any questions on product information and or technical support call 800 343 9463 Page 21 GCM 01 050410
8. ture During a Probe 1 failure alarm the bottle probe temperature can be monitored by pressing the Up or Down arrow to view the temperature history HES Differential for Energy Reduction This parameter is set at 4 which results in a set point of 58 F during energy reduction A decrease in this setting will decrease the set point and an increase in this feature will increase the set point ALARM CODES Message Cause Output pi Room probe failure Toggle Con and COF depending on your temperature needs if necessary or replace room probe Customer Service 1 800 343 9463 Page 10 SYSTEM OPERATION ADVANCED QT 8 WHISPERKOOL 1200 Condensate evaporator switch The QT s condensate evaporator is a heating element that evaporates excess condensate that accumulates in the cooling system as a byproduct of refrigeration Vinoth que units are equipped with sophisticated heating elements that automatically sense the presence of water and work until the water is gone On Turning the condensate evaporator on causes the heating element to operate whenever water is present in the compressor pan Off If your wine cellar is located in a dry climate there is a good chance that the unit will not accumulate excessive water Therefore save electricity by switching the condensate evaporator to the Off position Temperature equalizer The temperature equalizer switch control
9. 0 mile range of the Vinoth que authorized service center in Stockton Calif you will be responsible for charges arising out oftravel time to and from the cabinet s location The Factory Authorized Replacement unit comes with a complete 90 day warranty for both parts and labor and a 5 year warranty on the compres sor Please follow the correct guidelines when installing the replacement unit The replacement unit has undergone the following refurbishment process using only new replacement parts Compressor and condenser coil High and low pressure tubing e Thoroughly clean unit inside and out Vacuum charge and test the system e Unit includes new thermostat If you have any further questions please contact Customer Service This warranty does not cover cosmetic damage caused during installation or damage because of acts of God accident misuse abuse negligence commercial use or modification of or to any part of the product This warranty does not cover damage due to improper operation or maintenance connection to improper voltage supply or attempted repair by anyone other than a facility authorized by The Convenience Series to service the product This warranty does not cover products sold AS IS or WITH ALL FAULTS This warranty is valid only in the United States Proof of purchase in the form of a bill of sale or receipted invoice which is evidence that the unit is within the warranty period must be presented to obtain warranty
10. PECTING YOUR CABINET When the cabinet arrives inspect the unit to make sure that no damage has occurred during shipping Look for any marks tears or damage which might affect the cabinet If you notice any damage remove the packaging and see if the unit was affected in any way On QT Series cabinets specifically inspect the compressor pan located at the bottom rear of the unit Note if any oil has leaked into the pan In the event that damage has occurred you need to identify the extent of the damage on the shipping document This document will then be used to file a freight claim Immediately notify Vinoth que or your distributor to file a claim You can accept or deny the delivery if the unit is damaged Any damage must be noted by yourself and the installation crew on the shipping receipt which you both will be required to sign Based on the extent of the damage the cabinet may be returned to the factory and repaired or replaced For minor scratches the moving company will send a qualified furniture repair company representative for touch up work PLACING THE CABINET There are many considerations that have to be made in order to receive the best performance results from your Vinoth que cabinet Weight You will need to take into account that the weight of the unit fully loaded with wine bottles can be substantial as bottles weigh roughly 3 pounds each Ambient temperature The cooling system in the cabinet has the abil
11. WINE CABINET OWNER S MANUAL FOR CABINETS EQUIPPED WITH WhisperKOOL 2500 WhisperKOOL 1500 WhisperKOOL 1200 Advanced QT g CYinolh Cue WINE CELLARS Copyright 2010 Vinoth que Wine Cellars All rights reserved This manual the product design and the design concepts are copyrighted by Vinoth que Wine Cellars with all rights reserved Your rights with regard to the hardware and manual are subject to the restrictions and limitations imposed by the copyright laws of the United States of America Under copyright laws this manual may not be copied reproduced translated transmitted or reduced to any printed or electronic medium or to any machine readable form for any purpose in whole or in part without the written consent of Vinoth que Wine Cellars Every effort has been made to ensure that the information in this manual is accurate Vinoth que Wine Cellars is not responsible for printing or clerical errors Vinoth que Wine Cellars reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice Vinoth que and WhisperKOOL are registered trademarks and ECE is a trademark of Vinoth que Wine Cellars All rights reserved Mention of third party products is for informational purposes only and constitutes neither an endorsement norarecommendation Vinoth que Wine Cellars assumes no liability with regard to the performance or use of these produ
12. button and either the up or down arrow at the same time 1 Wine temperature indicator A red LED bar will light up when the thermostat is reading the liquid temperature in the bottle via the probe This will remain lit and the temperature you see displayed is what the probe is reading 2 LED screen Displays your thermostat readings 3 Wine temperature reading The temperature that the bottle probe is registering to the thermostat 4 Temperature SET indicator A red LED bar will light up when you are setting the temperature 5 Unit ON indicator A red LED bar will light up every time the unit turns on to run a cooling cycle 6 SET button Used to set the temperature you want the unit to maintain 7 UP arrow button Used with the SET button to set temperature higher In addition by pressing and holding the button it will allow you to see the five minute countdown 8 DOWN arrow button Used with the SET button to set temperature lower G Up and Down arrow buttons used simultaneously will change the temperature readout from Fahenheit to Celsius Page 13 GCM 01 050410 TESTING THE REFRIGERATION UNIT Remember do not start or plug in your unit for 24 hours after delivery Many units are placed on their sides during shipping which may allow compressor oil to escape their reservoirs Premature starting before the oil has had a chance to resettle can cause damage to the compressor and result in a lack of cooling Before you fill the
13. completes its start up check the compressor is locked out for five minutes During this time the RUN light will flash slowly All three lights will flash rapidly if there is no probe connected to the thermostat Buttons To change the set point temperature press either the Up or Down button The SET light will flash once for each 1 F difference This set point will remain in memory until you change it If you forget where the unit is set pressing the 55 button will reset the set point to 55 F and the set light will flash twice The temperature cannot be adjusted below 50 F or above 76 F Attempting to set the unit outside of this range will cause the SET light to rapidly flash Operation Whenever the compressor shuts off normally a five minute lockout period begins and the RUN light will flash slowly If the compressor runs for 90 continuous minutes a five minute defrost cycle is forced during which time the compressor will not run During this defrost cycle the RUN light will flash rapidly Customer Service 1 800 343 9463 Page 12 PDT OPERATING INSTRUCTIONS CO wine Temperature Indicator C2 LED Screen Wine Temperature Reading PDT Precision Digital Technology Thermostat Temperature SET C UP Arrow Button C8 DOWN Arrow Button Indicator Button C5 Unit ON Indicator Button C6 SET Temperature Button The unit is set at 55 F at the factory To raise or lower the set temperature press the set
14. cts GCM 01 030110 TABLE OF CONTENTS NOTE LO CUStOME E pg 1 Cabinet Installation it kit a kk tt e ka ak eko kiba aaa na oo one pg 2 System Operation WhIsp rKOOL 2500 amp 1500 vikeebes esse s kssasne nana pea ai fikse nas sipose ass pg 7 System Operation Advanced OT amp WhisperKOOL 1200 nm pg 11 Testing th Refrigeration UNE eki ko onn ey aa n a ik n pk pe e e a be apa pipe pg 14 Loading Bottles amp Cool DOWN Period wi stiksisitssisassaan panda sr niaskensosossonsssssaois stsas so gan esesssss bassassdodaskossosssos pg 14 Normal Operation amp Maintenance eessen pg 15 TOUDE AOU NA et fi kan era e pa a pe e a aR kt eta an op donna ne pg 16 EE pg 19 Testing a Return LIN Ce ak l kin oka ao kis aa an kk ks an epe a NO ka kk pa ak eka ok as oka kise AN DANS kd penso pg 20 Warranty IRON ete eos pg 22 Vinoth que Wine Cellars 1738 E Alpine Ave Stockton CA 95205 800 393 9463 www vinotheque com NOTE TO CUSTOMER Thank you for purchasing a Vinoth que wine cabinet Our main goals are customer satisfaction and provid ing the best wine storage solutions on the market If you have any questions or comments please feel free to contact us at 1 800 343 9463 or info vinotheque com Itis mandatory that you do not plug in or start your new Vinoth que cabinet for 24 hours after its delivery Units are sometimes placed on their side during shipping which might cause compressor oil to escape the reservoir Starting
15. e Temp History amp Scroll Button 7 ON OFF button 1 SET Down CPSM 5 7 Condenser Fan Reset Hi amp Lo Button 3 5 Alarm Pre Chill Display Note The 1 or the 3 5 stands for the amount of time in seconds that the button must be held ON OFF Up and Down buttons Cellar Pre Chill The ON OFF button turns the refrigeration system on or off This feature does not disconnect power from the unit The condenser fan will continue to run in the OFF position In order for the power to be shut off from the unit the power cord must be unplugged from the wall Use these buttons to scroll through the control panel menu These also display the highest and lowest temperature sensed by the bottle probe This feature allows the customer instant access to the recorded data applicable to the bottle probe temperatures it can be easily reset to reflect current temperatures 1 Press the Up arrow or the Down arrow once and the highest or lowest temperature Hi Lo sensed by the bottle probe will be displayed 2 To reset the Hi Low press and hold the Set button when the Hi Low value is displayed on the digital display continue to hold the Set button until RST appears on the digital display and then blinks This will erase the past recorded temperature data history and start recording from the current time and temperature forward Temperatures displayed would reflect bottle probe temperatur
16. elieve that our QT and WhisperKOOL systems are the quietest cooling units available for cabi nets they do produce a nominal amount of noise It is comparable to the noise a refrigerator emits during normal operation though the cooling unit may operate more often Keep this in mind when placing the unit The unit will run continually during the initial cool down period when the wine has first been introduced to the cabinet After that the cooling unit will run as needed in order to maintain optimal relative humidity levels and a precise temperature based on the ambient temperature If the unit is placed on a hard surface such as tile or hardwood floors it is recommended that you place a small piece of carpeting underneath the cabinet to prevent noise from echoing against the hard surface Humidity control The cabinets are designed to maintain relative humidity between 50 and 70 This is accomplished through the design and engineering of the cooling systems There are no special controls for this function The unit does not create humidity If you live in a dry climate you can add to the humidity of the cabinet by installing a humidistat Page 3 GCM 01 050410 LEVELING THE CABINET The cabinets have leveling legs that can be adjusted up or down with a wrench provided with unit as needed There are two primary reasons for leveling the cabinet To assure that the unit stands solidly on the floor without rocking back and forth
17. es from that point in time and beyond 3 The Hi Low feature should be reset at initial start up and after the cellar or cabinet has obtained normal operating temperatures generally 55 F e Activate the Cellar Pre Chill feature by pressing the Up button for 3 to 5 seconds and the CPC logo a yelowsnowflake inside a semicircle will be displayed on the digital display Terminate the CPC by pressing the Up button again for 3 to 5 seconds or the feature will self terminate after 6 hours 1 The CPC feature may be used to pre chill the cellar prior to loading it with warm bottles The feature will shift the set point down to a lower setting of 52 F for the next 6 hours After the 6 hour time period the set point will automatically return to the original set point Customer Service 1 800 343 9463 Page 8 WHISPERKOOL SERIES ADVANCED CONTROLLER CONT Cellar Pre Chill 2 The CPC feature can be adjusted to the customer s specific needs by accessing the control Customer Preference Selection Menu CPSM Page 9 panel menu Note This feature is not available on the remote keypad application 1 Press the Set button once and it will display the set point After about 5 seconds the display will return to normal operation and display the bottle probe temperature 2 Press and hold the Set button for 3 to 5 seconds until the set point is displayed and the F symbol starts blinking Then press the Up
18. ity to cool a maximum of 30 F below the ambient temperature in the room Since the optimal temperature for wine storage is 55 F make sure that the temperature of the room in which the cabinet will be placed does not exceed 85 F On the other hand to ensure a consistent temperature make sure the room doesn t dip below 55 F Customer Service 1 800 343 9463 Page 2 PLACING THE CABINET CONT Ventilation The cabinet must have adequate ventilation to allow the exhaust side of the cool ing unit to operate correctly As the unit cools on the inside condensing refriger ant creates heat which will need to dissipate away from the unit on the outside Some units have an exhaust fan mounted on top of the cabinet which forces air away from the unit vertically In order to avoid disrupting the ventilation do not A place anything on top of the cabinet ttt If your cabinet is not equipped with a front vent the unit must be placed in an open room Do not install it in a cabinet The rear of the unit should be placed about 2 from the wall There should also be about 12 of clearance above the top of the unit and 6 of free space on each side This will assure proper dissipation of heat and sustained cooling of your wines oXoXoXeXeXoXoX0 EZE N ALAE ONT EH E Noise Although we b
19. ll continue to run for about 1 minute This is a feature of the WhisperKOOL Humidity Management WHM system The WHM is an adjustable feature that allows the customer the convenience of managing the humidity enhancement of their wine cellar It is one of the many customer preference selection features that allow the customer the ability to fine tune the controls Anti Frost Cycle The Anti Frost Cycle is a precautionary measure as icing or frosting of the coil does not occur during normal operation The system will go througha defrost cycle every 4 hours During the defrost cycle the in cabinet fan will provide airflow across the coil which will evaporate any frost accumulation Bottle probe failure protection Should a bottle probe fail the Advance Product Safety Technology APST will automatically transition the refrigeration compressor cycles to a pre determined time series based on laboratory testing which will ensure that the temperature is kept within the safe range Control panel The control panel is designed to give the user the ability to monitor and change cellar conditions when the evaporating unit is placed in a remote location Page 7 GCM 01 050410 WHISPERKOOL SERIES ADVANCED CONTROLLER Button 7 Set Button View set point 1 Change set point 3 5 Energy Reduction Energy Reduction Defrost Compressor Cellar Pre Chill Button 3 5 Evaporator Fan High Bottle Temp History amp Scroll Button 1 Low Bottl
20. ot sealing Door gasket is twisted See next page properly Lost its flexibility Thermostat delay Allow enough time for thermostat startup delay Tripping circuit breaker Reset breaker verify dedicated 15 amp outlet and not on ground fault interrupter Temperature settingiswrong Adjust your set temperature ____ Wine probe disconnected Assure probe line is in a bottle of water and is not stretched Runs constantly Thermostat setting It may be set too cool raise the set temperature Cabinet recently loaded with wine Wait It may take several weeks to reach optimal storage temperature Ambient room temperature Adjust the temperature in the room Units are designed to cool 30 F below room temperature H Inadequate ventilation Assure proper space above behind and on the side of the unit Do not set anything on top Boor gasket not sealing properly See next page set temperature rectly next page ee M 3 Customer Service malfunction equalizer on pg 14 running constantly e ie Customer Service a GFI Vinoth que customer service 800 343 9463 8 a m to 4 p m PST Monday through Friday support vinotheque com Customer Service 1 800 343 9463 Page 16 TROUBLESHOOTING CONT Door gasket not sealing correctly If the cabinet s cooling system is running continually without reaching the desired temperature the problem may lie with the door gaskets not sealing correctly Examine the door gasket around the entire
21. r than the cabinet on one side If the door is angled lower than the cabinet slightly raise the side to which it is leaning Q Q Front view Two door unit Front view Single door unit Page 5 GCM 01 050410 LIQUID MEASURING THERMOMETER All cabinets come with our Precision Digital Technology liquid temperature measuring thermostat system With this technology a bottle probe relays information back to the thermostat giving you a reading of the wine not of the air around it Aside from the probe the system offers other advantages A built in defrost cycle The unit is designed to shut off for five minutes every 90 minutes in order to prevent frost This allows the cooling unit to cool effectively in demanding environments Heavy duty circuitry The system is resistant to power surges which can play havoc on electrical components This improvement will ensure years of trouble free use However we still recommend that you install a surge protector specifically for the unit Fahrenheit and Celsius readouts The thermostat has the ability to produce the readout in both Fahrenheit and Celsius for overseas users By measuring the temperature of the liquid the temperature reading will be consistent and the unit will only run when it needs to To install the thermostat 1 Fillan empty wine bottle to its neck with room temperature water 2 Press bottle probe securely into bottle 3 Place the bottle with probe into a level
22. s the fan which is mounted on top of the evaporator plate It is de signed to keep air moving throughout the cabinet in order to maintain consistent temperature between its upper and lower half Auto During normal operation set the switch to the Auto position The fan will operate whenever the cooling system is running Continuous This feature runs the fan continuously similar to WHM see pg 10 Off Shuts off the fan for noise reduction Do not become overly concerned about air emperature variations Remember the unit measures liquid tem perature not air temperature The unit will operate when the liquid temperature varies Page 11 GCM 01 050410 PDT JR OPERATING INSTRUCTIONS PDTur PRECISION DIGITAL TECHNOLOGY THERMOSTAT TEMPERATURE WE m Operating instructions for the Vinoth que PDT Jr Thermostat for the OT Series cabinets Indicators There are three colored lights on the left side of the thermostat PWR Green The unit is powered RUN Yellow The compressor is running If the light is flashing the unit is in the five minute lockout SET Red This light flashes when the set point temperature is changed by pressing one of the three control buttons It flashes once for each press of the Up or Down button and twice when the 55 button is pressed When the unit is first turned on all three lights flash slowly while the thermostat starts up Once the unit
23. stment to Humidity Enhancement you should wait a minimum of three days before making any additional adjustments This will allow the cellar sufficient time to acclimate to the new setting Fof Humidity Management Enhancement This parameter is normally set at 5 This parameter usually should not be adjusted as it provides an off cycle time for the fan during the compressor off cycle CCS Cellar Pre Chill Set Point This parameter is set at 52 F but can be adjusted to a set point between 45 F and 67 F bLL Act Compressor off or on for low bLL or high Act temperature alarm These parameters are set at n With this parameter set at n the refrigeration system will continue to operate normally if there is a high or low temperature alarm To change this parameter change the setting to y and the compressor refrigeration system will shut off during a high or low temperature alarm GCM 01 050410 WHISPERKOOL SERIES ADVANCED CONTROLLER CONT Customer CON COF Compressor on time CON and off time COF with a Probe 1 failure alarm Preference These parameters are set at CON 40 minutes and COF 10 minutes In the event that there Selection is a Probe 1 failure alarm the compressor refrigeration system automatically starts a Menu predetermined ON OFF cycle which is controlled by the CON and the COF parameters cont The customer can adjust these parameters to maintain the desired bottle probe tempera
24. tes it is not recommended to request yours in this style The Vinoth que panel construction is a sandwich of rigid insulating foam between two outside veneer panels This construction will only deform if the moisture content of one panel is at variance with that of the other A warpage condition which is reversible might develop during transportation or after installation in an ambient environment substantially dryer or substantially more humid than that in which the unit was manufactured and packaged with the doors closed only exterior panel of door exposed to ambient For example a unit manufactured in California during the rainy season winter and installed in an eastern heated room will tend to develop a concave warp as the outside exposed veneer panel dries up while the same unit built in the dry summer weather and installed in Florida will develop a convex warp as the exposed panel absorbs outside moisture How to correct a warped door Leave the door open to expose both door surfaces to the same outside condition for 24 to 48 hours To accelerate the process wet the contracted dry door panel with a damp towel or sponge and allow drying with both door sides exposed How to prevent future warpage Thoroughly seal both sides of a straight door with two coats of high quality moisture proof wood sealant to prevent any further moisture exchange Never seal a warped door as it might be impossible to correct the condition after
25. the cabinet 4 Loosen the seals by slidingascrewdriver between the cabinets and cooling unit housing then remove the cooling unit 5 The cooling unit should then be bubble wrapped and insulated for the shipment back to the factory 6 Oncethecoolingunitarrivesatthe factory it willbe tested in a controlled environment An evaluation will be doneandacustomerservicerepresentativewillcallyouwiththecorrespondinginformation Theturnaroundtimeis usually about 3 to 5 business days 7 Ifthe unit is repaired under warranty the factory will pay for shipping the unit back to the customer and in addition will reimburse the customer for the initial shipping charges shipping ground charges 8 If the unit is determined to be working correctly the customer will be responsible for paying the freight to have the unit returned Page 19 GCM 01 050410 TESTING A RETURN UNIT All units sent in for repair are tested thoroughly They undergo a complete line of testing that includes amperage load for electrical malfunctions thermostat graph testing to document the units ability to cool sufficiently and if needed the unit will be tested on its ability to hold a Freon charge If the unit checks out as running correctly the customer will be responsible for paying an inspection fee and the freight charges associated with returning the unit After the warranty period you must pay for all labor charges In the event that your cabinet is not located within a 2
26. the unit before the oil has had a chance to settle again can cause damage to the compressor and negatively affect cooling AN A dedicated 20 amp circuit is highly recommended for optimum operation Tripped breakers and deficient performance if other devices are pulling power from the same circuit Do not use a Ground Fault Interrupter GFI with this product The cooling unit will draw more amperage than the GFI will allow It is recommended that you plug your unit into a surge protector or power conditioner Just like with any sensitive electrical equipment the unit s circuitry may be damaged by power surges and spikes which are not covered by the warranty For cabinets with PDT and PDT Jr systems upon plugging the unit in and turning it on there will be a five minute delay before it starts Page 1 GCM 01 050410 CABINET INSTALLATION Cabinet installation is a very simple process spending a small amount of time fine tuning the cabinet will ensure cabinet aesthetics and longevity These are the simple steps for installation further explained on the indicated pages 1 Inspect the cabinet below Unpack the cabinet and clean up the debris Place the cabinet in a suitable location in your home below Level the cabinet pg 4 On QT Series remove the protective panel from the rear of the cabinet do not remove the panel on front venting cabinets Adjust the doors pg 7 7 Attach the door handles um W N m INS
27. tor Temperature equalizer During the cool down period the system will run constantly depending on the size of the collection Slow cooling maintains correct humidity within the cabinet Customer Service 1 800 343 9463 Page 14 NORMAL OPERATION 8 MAINTENANCE The cooling unit will cycle on and off as needed once the temperature has stabilized and the initial cool down has been completed The condensate evaporator and temperature equalizer switches may be turned off for normal operation Thermostat Should be 55 F or desired wine temperature Condensate evaporator Switch On or Off as ambient humidity requires In areas of high humidity leave the switch On to evaporate excess condensation In environments of low humidity leave the switch in the Off position Temperature equalizer Turn on whenever a temperature difference is noted between the top and bottom bottle rows Maintenance Vinoth que recommends vacuuming of the condenser fins located in the rear of the cabinet every three months A partially obstructed condenser dramatically reduces the efficiency of the cooling unit Monthly Check filters Check for unusual noise or vibration Quarterly Clean filters o Remove grille ducting on the evaporator o Remove the filter covering the coil o Wash with warm water o Dry off filter by shaking off excess water Page 15 GCM 01 050410 TROUBLESHOOTING Door gasket n
28. treatment Vinoth que is not responsible for reversible moisture induced warpage of unfinished doors or for door stained and or sealed after shipment from the factory Freight damage claims If damage has occurred to your cabinet during the course of shipping it is the responsibility of the distributor from which you bought the unit to work directly with you and the freight company to arrange for repairs or replacement It is imperative to inspect the unit thoroughly at the time of delivery to assure that any damage is observed and noted on the shipping document The freight company will not accept liability for damage without documentation on the delivery paperwork Customer Service 1 800 343 9463 Page 18 COOLING UNIT REPAIRS Ifrepairs are needed to the cooling unit it must be returned to the factory for evaluation and repair 1 Contact our customer service department 800 343 9463 and describe the problems you are experiencing with the unit The customer service department will first seek to determine that no external factors are contributing to the improper operation of your cooling unit 2 Once it is determined that the unit is operating incorrectly the customer service department will issue an RMA return merchandise authorization number This number must be included on the package of the returned cooling unit 3 Remove the cooling unit from the cabinet by unscrewing the mounting screws located on the top and rear of
29. unit You can also check this by turning on the cabinet s interior light and turning off the lighting in the room Determine if there is an area that is not sealing properly If a problem exists use the following guidelines to resolve the problem Heat up the gasket with a hair dryer while using your fingers to pull the gasket outward Doing this for several minutes will f loosen the gasket material and increase its flexibility S Close the door and determine if the magnetic strip within the gasket will seal with the metal strip on the door e Repeat steps until gasket seals correctly Once it has reseated itself leave the doors closed for two to three hours The seal should retain the new shape after this process Door realignment The door can be adjusted by loosening the three Allen head bolts easier done from the outside securing the top and bottom pivot hinges through slotted mount ing holes and moving the hinge s in the appropriate direction Re tighten the bolts after the adjustment is completed only after checking the level of the cabinet Page 17 GCM 01 050410 TROUBLESHOOTING CONT Unfinished wood cabinets are NOT warranted against warpage Although the finest craftsmanship and materials are always used to make Vinoth que products unfinished wood cabinets are not warranted against warpage Because the grain of the wood is not sealed against potential warpage that can occur through different kinds of clima
Download Pdf Manuals