1. UTICA BOILER S SVB Series II There Are Some Things You Can Always Depend On Up to 84 4 AFUE Gas Fired Hot Water Boiler e Available in 6 sizes from 42 MBH to 225 MBH e Dependable Cast Iron Heat Exchanger with Cast Iron Push Nipples The Sections and Push Nipples expand at the same rate when heated By using similar materials instead of less expensive gaskets the boiler maintains a water tight seal over time e Honeywell High Limit Electronic Ignition Control Recessed under the boiler s protective jacket Digital temperature display and diagnostics Plug in connection for the inducer fan Plug in connection for the system pump Control monitors the water temperature and delays the burner starting until residual heat has been transferred This maximizes efficiency by turning on the burner only when needed e Induced Draft Fan allows flue gases to be pulled through the boiler and exhausted through a chimney or side wall vent e Textured paint Jacket Small compact design is ideal for low clearance installations e Limited Lifetime Warranty Residential Applications e Made in the USA Utica SVB Series II Gas Fired Hot Water Boiler Heating Net AHRI Vent Diameter Model Input Rate C Zi 1g Rating AFUE Diagram ode MBH Capacity Water To Chimney Horizontal Vent o MBH MBH 2 Category I Category III Dimensional Front A TEMPERATURE SUPP
2. LY PRESSURE 1 1 000 Btuh British Thermal Unit Per Hour Boilers are equipped for altitudes up to 2 000 feet only For altitudes above 2 000 feet ratings should be reduced at the rate of 4 for each 1 000 feet above sea level Heating Capacity based on D O E Department of Energy test procedure 2 Net AHRI Water Ratings indicate amount of remaining heat input that can be used to heat the radiation or terminal units Net AHRI Ratings shown are based on an allowance of 1 15 Selection of boiler size should be based upon Net AHRI Rating being equal to or greater than calculated heat loss of building Manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements 3 Boiler is provided with a 3 x 4 increaser for chimney vent applications This does not infer that the connection to the chimney will always be 4 Please refer to IOM National Fuel Gas Code ANSI Z223 1 NFPA54 or applicable provisions of the local building codes for details concerning proper chimney connections General Information See instalation Operation and Maintenance Manual for complete instructions Clearances Combustible Materials Required 4 Required distances 6 152 mm measured from boiler Definition of Alcove is three sided space Control Side 8 203 mm with no wall in front of boiler ree poise Opposite Side 6 152 mm for alcove is 18 inches f spoil
3. ers to Front Alcove 18 457 mm leading edge of side walls as 8 honn anon Flue Vent Connector 6 152 mm Connections 3 All Models Return Supply Water 1 1 4 Gas In 1 2 NPT Electrical 120 Volts AC 60 hertz 1 phase Less than 12 amps 15 amp circuit recommended Water SVB 2 1 75 Gallons SVB 3 3 00 Gallons SVB 4 4 25 Gallons SVB 5 5 50 Gallons Content SVB 6 6 75 Gallons SVB 7 8 00 Gallons Model A Width B Height C Depth Weight SVB 2 23 1 4 225 Ibs a SVB 3 14 1 4 23 1 4 265 lbs enone SVB 4 17 112 23 1 4 322 Ibs Weights SVB 5 20 3 4 23 1 4 370 Ibs SVB 6 23 1 4 431 Ibs SVB 7 27 1 4 23 1 4 480 Ibs Standard Boiler Control Module Recessed Honeywell Control High Limit Electronic Ignition Control Equipment User Display Interface Digital Temperature Display Heat Exchanger Cast Iron Sections with Cast Iron Push Nipples Combustion Completely Installed and Wired Gas Control System with Titanium Composite Burners and Manifold consisting of Automatic Redundant Combination Gas Valve 24 Volt Intermittent Pilot Control Continuous Retry 100 Shut Off Combination Pilot Burner Electrode Flame Sensor Electrical 24 Volt Transformer Service Switch Safety Flame Roll Out Safety Shut Off Fuse Link and Pressure Switch vent safety shutoff with Spare Fuse Link included Other Assembled Boiler with Insulated Jacket Induced Draft Fan Combination Temperature Pressu
4. re Gauge Circulator Pump 34 Drain Valve 30lb ASME Relief Valve Natural Gas or Propane Combustible Floor Plate Fill Trol Thimble Sidewall Vent Hood _ SWITCH MANIFOLD Left Side Control Panel Internally Located Right Side 23 1 4 iia BLOWER PRESSURE SWITCH Certifications At CERTIFIED www ahridirectory org C S A Certified For Tested for 50 psi Natural Gas Or Propane ASME Working Pressure All ratings and specifications subject to change PN 240009708 Rev 1 15 Contractor l PO Box 4729 Assistance 3 RA Utica New York 13504 V UTICA J j tel 315 797 1310 fax 315 797 3762 www uticaboilers com BOILERS

Download Pdf Manuals

image

Related Search

Related Contents

DataView PowerPad III Control Panel User`s Manual  Manual tesoura Site  Télécharger ce fichier  Capacidades y criterios de evaluación: Contenidos:  manuale d`uso instruction manual notice d`utilisation  Sandberg Aerial Connection M-M 9.5 mm  Sunbeam Bedding SCH8211 User's Manual  Philips Ecomoods Suspension light 40770/35/16  Karcher SE 3001 Vacuum Cleaner User Guide Manual Instruction  Evolution Technologies MK-425C User's Manual  

Copyright © All rights reserved.
Failed to retrieve file