1. TCB 2SD TBD 2SD TBB 2SB TBB 2SG TCB 3SD TBD 3SD TBB 3SB TBB 3SG TCB 4SD TBD 4SD TBB 4SB TBB 4SG x This picture is a plan view of bottom cabinets CB is an abbreviation of the caster with a brake Other casters don t have a brake DRAFT ARMS TOWERS Installation Schemati Screw M4xL12 x 4EA T Th Screw M4xL12 x 4EA j rif aie TCB 2SD TCB 3SD TCB 4SD TBD 2SD TBD 3SD TBD 4SD TBD 2SB TBD 3SB TBD 4SB Assemble DRAFT TOWER as above drawing Distributor Fixture _ So o Nu 2 ae Si SN _N AN KA KAA j e H A R rt Sc SS TCB 2SD TCB 3SD TCB 4SD TBD 2SD TBD 3SD TBD 4SD TBD 2SB TBD 3SB TBD 4SB Assemble BEER LINE amp CQ2 LINE as above drawing CAUTION IMPORTANT Don t pull out or Turn drain line DIRECT DRAW On direct draw dispensers the drain is located at the front of the cabinet To plumb in the drain connect 5 8 P V C pipe to the 5 8 barbed fitting supplies with the unit CAUTION IMPORTANT TBB 2SG TBB 3SG O TBB 4SG A Excessively opening the door will cause the breakdown B Handle with care as shutting the door 1 POWER CORD Be sure the power cord is connected to the proper voltage and amps should be run before connecting power cord to outlet A protected circuit of the correct voltage and amperage must be run for connec
2. existence of the alleged defect If compressor is replaced under warranty Turbo Air will either request the compressor or compressor tag be returned Compressor or tag must be returned with all information related to the unit Any action or breach of these warranty provisions must be commenced within one year after said cause of action has occurred One Year Parts amp Labor Warranty Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit the cabinet and all parts thereof to be free from defects in material or workmanship under normal and proper use and maintenance service as specified by Turbo Air and upon proper installation and start up in accordance with the instruction packet supplied with each Turbo Air unit Turbo Air s obligation under this warranty is limited to a period of one 1 year from the date of original installation or 15 months after shipment date from Turbo Air whichever occurs first Any parts covered under this warranty that are determined by Turbo Air to have been defective within one 1 year of original installation or fifteen 15 months after shipment date from manufacturer whichever occurs first is limited to the repair or replacement including labor charges of defective parts or assemblies The labor warranty shall include standard straight time labor charges only and reasonable travel time as determined by Turbo Air Additional Four Year Compressor Warranty In addition to the on
3. NIT ALTERATION NEGLECT ABUSE MISUSE ACCIDENT DAMAGE DURING TRANSIT OR INSTALLATION FIRE FLOOD ACTS OF GOD Turbo Air is not responsible for the repair or replacement of any parts that Turbo Air determines have been subjected after the date of manufacture to alteration neglect abuse misuse accident damage during transit or installation fire flood or act of God IMPROPER ELECTRICAL CONNECTIONS TURBO AIR IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM ELECTRICAL POWER FAILURE THE USE OF EXTENSION CORDS LOW VOLTAGE OR VOLTAGE DROPS TO THE UNIT NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESSED IMPLIED OR STATUTORY EXCEPT THE ONE 1 YEAR PARTS amp LABOR WARRANTY AND THE ADDITIONAL FOUR 4 YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF OUTSIDE U S AND CANADA This warranty does not apply to and Turbo Air is not responsible for any warranty claims made on products sold or used outside the United State and Canada CHANGES MADE TO WARRANTY COMMENCED ON 5 1 2002 Jurb REFRIGERATOR MANUFA val TURER 1250 Victoria street CARSON CA 90746 TEL 310 900 1000 FAX 310 900 1077 Toll F
4. Turbo air Speeds Up the Pace of Innovation REFRIGERATOR MANUFACTURER Urbo ar Beer Dispenser amp Back Bar Cooler Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment TCB 2SD TCB 3SD TCB 4SD Stainless Steel e TBD 1SD TBD 2SD TBD 3SD TBD 4SD Stainless Steel TBD 1SB TBD 2SB TBD 3SB TBD 4SB Black Paint TBB 1SB TBB 2SB TBB 3SB TBB 4SB Solid Door TBB 2SG TBB 3SG TBB 4SG Glass Door This equipment is intended for the storage and display of non potentially hazardous bottled or canned products only CONTENTS q OPEGCIFICATIONS creer sonst erceene nearen r EEEE me aa INI Retest sone eon yo ys ae asee ae seen nba seeeen Us easoconsauondees INSTALLATION OF THE CASTERS ic cccccccccccseseecccecticecseecescseeess Draft Arms Towers Installation Schematic Diagram 00 Beer Line amp CO2 Line Installation Schematic Diagram Caution IMPORTANT rerea eee eee nee EEE A NOT AELA TION carea E er ere GEEANIN G oea eee eee eee eee eee Br OPE IN eters eee tee ee BEFORE Pe GES TING ye accesses ee WARRANTY srera Eninde EE suns nce eeiteciansanstpeeaneneuesaa cas SERIAL NUMBER The serial number is located on the rating label which is on interior left side wall Please retain the unit s serial number for service purpose INSTALLATION OF THE CASTERS According to model refer to the assembly position of casters
5. e 1 year warranty stated above Turbo Air warrants its hermetically sealed compressor to be free from defects in both material and workmanship under normal and proper use and maintenance service for a period of four 4 additional years from the date of original installation but not to exceed five 5 years and three 3 months after shipment from the manufacturer Compressor determined by Turbo Air to have been defective within this extended period will at Turbo Air s option be either repaired or replaced with a compressor or compressor parts of similar design and capacity The four 4 year extended compressor warranty applies only to hermetically sealed parts of the compressor and does not apply to any other parts or components including but not limited to cabinet paint finish temperature control refrigerant metering device driers motor starting equipment fan assembly or and other electrical component etcetera 404A 134A Compressor Warranty The four year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to 1 This system contains R404A or R134A refrigerant and polyolester lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A 620 copper drier or better is highly recommended 3 Micron level vacuums must be achieved to insure low moisture levels in the sys
6. is opened too frequently or left open too long e The temp dial is not on the correct position e The condenser is clogged e The floor is too weak or the leveling feet are set incorrectly e The backside of the unit is too close to the wall There is a loud noise There are dew drops on the unit exterior e High moisture air can produce dewdrops during rainy seasons There are dew drops on the unit interior SOLUTIONS e Turn the temperature dial to a warmer setting e Check the power cord to make sure the unit is pluged in it correctly e Move out of sunlight or away from heater e Check the condition of stored food e Check the position of the temp control dial e Check the installation e Wipe with a dry cloth e Keep the door closed to remove dewdrops e The door is opened too frequently or left open too long The following points are not malfunctions e A water flowing sound can be heard when the compressor stops This is the sound of REFRIGERANT flowing e The compressor does not run during the defrost cycle REFRIGERATOR MANUFA al URER W t lurbo air ii Warranty Claims All claims for labor or parts must be made directly through Turbo Air If unit was manufactured more than one year proof of purchase must be faxed in or sent with claim All claims should include model number of the unit the serial number of the cabinet and all pertinent information supporting the
7. must be free of dust dirt and grease This will require periodic cleaning Condenser fins should be cleaned at least every three months 90 days or as needed To clean condenser unplug the unit Condenser can be cleaned with vacuum brush or CO high pressure air 3 CLEAN THE GASKET The door gasket should be cleaned frequently to maintain proper sealing 4 CLEAN THE DRAIN PAN Empty the Drain Pan which is located under the unit periodically When reinstalling Drain Pan make sure Drain Hose is placed back in pan 5 CHECK AFTER CLEANING Plug unit back in Check that the unit is operating properly BASIC OPERATION 1 The controller thermostat is located at the back right inside of the unit 2 The factory setting maintains about 38 F 3 C inside 3 Set toward counter clock wise warmer temperature and clock wise for colder temperature NORMAL COLD COOL OFF Temperature Controller Thermostat 4 The thermostat controls compressor s cycling by sensing inside temperature 5 When unit will not be used for a long time unplug the unit BEFORE REQUESTING SERVICE SYMPTOMS CAUSES Cooler is freezing e Thermostat set too cold products The unit does not refrigerate at all e There is a power connection failure problem The unit does not refrigerate well e The unit is in sunlight or near a heating device e Product was put in warm e The unit door
8. ree 1 800 627 0032 U S A In Canada http www turboairinc com
9. tem 500 microns or lower must be obtained 4 When compressor is grounded suction filter drier and 620 drier or better must be replaced a Compressor must be obtained through Turbo Air Inc unless otherwise specified in writing through Turbo Airs warranty department What Is Not Covered By This Warranty Turbo Air s sole obligation under this warranty is limited to either repair or replacement of parts subject to the additional limitations below This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty NO CONSEQUENTIAL DAMAGES TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS PROFIT LOSS OR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION LOSSES OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT BECAUSE of REFRIGERATION FAILURE WARRANTY IS NOT TRANSFERABLE This warranty is not assignable and applies only in favor of the original purchaser user to whom delivered ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN MADE AND SHALL VOID ALL WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IMPROPER USAGE TURBO AIR ASSUMES NO LIABILITY FOR PARTS OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER DAMAGES RESULTING FROM IMPROPER USAGE OR INSTALLATION OR FAILURE TO CLEAN AND OR MAINTAIN PRODUCT AS SET FORTH IN THE WARRANTY PACKET PROVIDED WITH THE U
10. tion of the line cord Unplug the unit whenever performing maintenance functions or cleaning the refrigerated cabinet Compressor warranty Is void if burnt out due to low voltage 2 RE STARTING If unpluged wait 5 minutes before re starting INSTALLATION GOOD AIR CIRCULATION Do not place any object that will restrict air flow in front or back grills Turbo air highly recommends that there is ample space in rear of unit 3 inches or more is best b 2 PLACE ON STRONG GROUND Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents 3 DO NOT PLACE NEAR HEAT Be sure to avoid hot corners and locations near stoves High ambient temperature will make cooling efficiency lower 4 INDOOR USAGE ONLY Be sure to install this unit indoor so it will not get wet from the rain 5 STABILIZING Make sure the unit is installed in a stable condition 6 LEVELING Be sure that the unit is level from front to back and side to side 7 Do not plug in with other units on same breaker 8 Do not run on extension cord CLEANING Before cleaning unplug the unit 1 CLEANING THE INTERIOR AND EXTERIOR The interior and exterior of the unit can be cleaned using warm water with soap Do not use an abrasive cleaner because it will scratch the surface 2 CLEANING THE CONDENSER FINS To maintain proper refrigeration performance the Condenser coil

Download Pdf Manuals

image

Related Search

Related Contents

  SMART SiX 6-14 Area operativa  プラクティビュー ミラー  Instructions for Servicing Vintage Sunbeam Mixmasters  Morphy Richards Bagless Cylinder Vacuum Cleaner User's Manual  Krystal Touch of NY DL3616ABPAS Installation Guide : Free Download, Borrow, and Streaming : Internet Archive  Adcom ACE-615 Surge Protector User Manual  