1. PV 1000FC B PV 2000FC 5 9 4 3 PV 2400FC guns o AAS O LA Ar ONDA A AA 20 AC Receptacles All Models Off On Switch PV 500FC and PV 1000FC Remote Off On Switch PV 2000FC and PV 2400FC Load Low Med High LEDs All Models Battery High Med Low LEDs All Models DC Input Terminals All Models Resettable Circuit Breaker All Models Remote On Off Connector PV 500FC and PV 1000FC APS PV Remote Connector PV 2000FC and PV 2400FC Recept culos de CA Solamente en los modelos con cable de CA Interruptor de Encendido Apagado PV 500FC y PV1000FC Interruptor de Remoto Encendido Apagado PV2000FC y PV 2400FC Luces Indicadoras de Carga Baja Media Alta Todos los modelos Carga de Bater as Alta Media Baja Todos los modelos Terminales de Entrada de CD Todos los modelos Interruptor de Circuito con Restablecimiento Todos los modelos Conector para el M dulo de Control Remoto PV500FC y PV 1000FC Conector para el M dulo de Control Remoto PV 2000FC y PV 2400FC 93 1551 200002001 0400
2. Disyuntor con Restablecimiento Todos los modelos Este interruptor de circuitos protege al PowerVerter contra da os producidos por sobrecargas de salida Si saltara el interruptor o disyuntor desconecte algunos equipos del PowerVerter para prevenir sobrecargas espere 1 minuto para permitir el enfriamiento de los componentes antes de restablecer el interruptor de circuitos o disyuntor 8 Conector para Interruptor Remoto de Encendido Apagado PV 500FC y PV 1000FC Este contacto puede utilizarse para conectar un control remoto con cable de encendido y apagado suministrado por el usuario 9 Conector para APS PV Remote control remoto para APS PV PV 2000FC y PV 2400FC Este contacto tipo RJ11 puede utilizarse para conectar un control remoto Tripp Lite opcional de APS PV vendido por separado y as monitorear y controlar remotamente la operaci n del PowerVerter Refi rase a las instrucciones incluidas con el control remoto Tripp Lite para obtener informaci n sobre su instalaci n operaci n y mantenimiento Mantenimiento y Servicio Mantenimiento El PowerVerter no requiere mantenimiento alguno pero debe conservarse seco en todo momento Peri dicamente verifique que todos los cables conectados a la unidad y a las bater as est n firmemente ajustados Limpie y apriete estas conexiones como lo considere necesario Servicio Si necesita enviar el PowerVerter a Tripp Lite por favor emp quelo cuidadosamente utiliza
3. Refer to Diagram 6 page 18 to connect a PV 2000FC or 2400FC or refer to Diagram 9 on page 19 to connect a PV 500FC or 1000FC Use this advanced connection to if you plan to use your PowerVerter to power large loads for long periods of time using a battery bank This connection uses a battery isolator to provide power from a parallel battery bank without draining the vehicle s battery When using multiple batteries in parallel each battery s voltage must be equal to the voltage of your PowerVerter s Inverter Nominal Input Voltage see specs 3 Use SHORT HEAVY GAUGE battery cabling Use 4 cabling with the PV 500FC and PV 1000FC use 2 0 cabling with the PV 2000FC and PV 2400FC Make the battery connection cable lengths as short as possible and in no case longer than 10 feet Shorter and heavier gauge cabling limits DC voltage drop and allows maximum transfer of current You must tighten your battery terminals to approximately 4 Newton meters of torque to create an efficient battery connection and prevent excessive heating insufficiently tightening the terminals could void your PowerVerter s warranty PowerVerter Plus models are capable of delivering a much higher wattage output for brief periods of time Wiring should be configured to handle this brief high current draw Though your PowerVerter is a high efficiency converter of electricity its rated output capacity is limited by the length and gauge of the wires running from the battery to
4. X Your PV s Nominal Input Voltage X El Voltaje Nominal de Entrada del PV Seespecifications Vealas especificaciones X 2 Volts Series Battery Vehicular Connection Conexi n en Serie de Bater as en Veh culos PV500FC or PV 1000FC See Pg 5 PV500FC o PV 1000FC Vea p gina 13 8 1isthealternator 8 1 representa el alternador 8 2isthe vehicle battery ground 8 2 representa la conexi n atierra de la bater a del veh culo 8 3isthe vehicle battery 8 3 representa la bater a del veh culo 8 4 is the fuse 8 4 representael fusible X Your PV s Nominal Input Voltage X El Voltaje Nominal de Entrada del PV See specifications Vealas especificaciones XVolts O Parallel Battery Vehicular Connection Conexi n Paralela de Bater as en Veh culos PV500FC or PV 1000FC See Pg 5 PV 500FC o PV 1000FC Vea p gina 13 9 1 isthe alternator 9 1 representa el alternador 9 2is a battery isolator 9 2 representa el aislador de la bater a 9 3isthe vehicle battery ground 9 3 representa la conexi n atierra de la bater a 9 4is the vehicle battery 9 4 representa la bater a del vehiculo 9 5 are auxiliary vehicle batteries 9 5 representa la bater a auxiliar del veh culo 9 6isthefuse 9 6 representa el fusible X Your PV s Nominal Input Voltage X El Voltaje Nominal de Entrada del PV See specifications Vealas especificaciones 19 A PV 500FC
5. an hour after an AC power outage She divides the total wattage of her equipment 150 watts by her PowerVerter s DC input voltage 12V and multiplies by 1 hour to get a Battery Amp Hours Required Rough Estimate of 12 5 She multiplies this by 1 2 for inefficiency then divides by 50 since a battery that discharges in an hour only provides about 50 of its stated amp hour capacity and determines that her 12V batteries amp hour capacities must add up to at least 30 The wattage rating is usually stated in a device s manual or on its nameplate If your equipment is rated in amps rather than watts you can approximate its watt rating by multiplying its ampere rating by its input voltage 120 Battery Connection PowerVerter Plus inverters are often connected to vehicle batteries that are recharged by the vehicle s alternator The following directions describe several possible vehicular connections PowerVerter Plus inverters are also suitable for use with battery banks that are recharged by gas generators utility power wind water or solar generators and other AC sources The following directions can be adapted for the connection of a PowerVerter to such a battery bank replacing the alternator in the connection diagrams with the variant charging system The user must determine the proper connection method for the variant charging system Never operate a PowerVerter directly from an alternator or other charger always connect both to an int
6. repairing or replacing atits sole option any such defective products To obtain service under this warranty you must obtain a Returned Material Authorization RMA number from Tripp Lite oranauthorized Tripp Lite service center Products mustbe returnedto Tripp Lite or an authorized Tripp Lite service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase This warranty does not apply to equipment which has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase EXCEPT AS PROVIDED HEREIN TRIPP LITE MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE INNO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically Tripp Lite is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third pa
7. the PowerVerter Operation amp Features See Diagram 10 p 20 to locate the following switches indicator lights and other features 1 AC Receptacles All models These output receptacles provide AC power to connected equipment The PV 500FC and the PV 1000FC feature NEMA 5 15 receptacles while the PV 2000FC and 2400FC feature NEMA 5 20 receptacles Plug your equipment into these outlets as if they were utility wall AC outlets Note the total power demand of all equipment connected to your PowerVerter s output receptacles must not exceed your PowerVerter s power ratings see Specifications p 8 for your model s Continuous and Surge Power Ratings Also note that these outlets provide no connection to ground Power Switches 2 OFF ON Switch PV 500FC and PV 1000FC Move this switch to the ON position to have your PowerVerter provide connected equipment with AC power by converting DC power from an attached battery e Move this switch to the ON position to control the PowerVerter at a distance with a user supplied on off switch Leave this switch in the OFF position when not using connected equipment to prevent battery drain 3 REMOTE OFF ON Switch PV 2000FC and PV 2400FC Set this 3 position switch to REMOTE to control your PowerVerter at a distance with a Tripp Lite PV APS Remote sold seperately Move this switch to the ON position to have your PowerVerter provide connected equipment with AC power by
8. AD LOW MED HIGH carga baja media alta Todos los modelos Estas tres luces indican la demanda aproximada de energ a conectada al PowerVerter Plus Luces Encendidas Carga Conectada Aproximada Verde 0 50 Verde y Amarilla 51 75 Amarilla 76 100 Roja 100 125 Todas apagadas Inversor apagado Parpadeando en rojo 2 veces segundo Sobrecarga Parpadeando en rojo 4 veces segundo Sobrecarga cierre del inversor 5 Luces BATTERY HIGH MED LOW bater a alta media baja Todos los modelos Estas tres luces se encienden en varias secuencias para indicar el nivel aproximado de carga y el voltaje del banco de bater as conectado y alertarle sobre varias fallas posibles Luces Encendidas Capacidad Verde Completa Verde y Amarilla 80 Completa Amarilla 60 80 Amarilla y Roja 40 60 Roja 20 40 Parpadeando en rojo 2 veces segundo 0 20 Parpadeando en rojo 4 veces segundo 0 cierre del inversor Otras Caracter sticas 6 Terminales de Entrada de CD Todos los modelos Los tornillos o tuercas tipo mariposa de los bornes o terminales sujetan los cables provenientes de la bater a externa o sistema externo de bater as La bater a o sistema de bater as debe suministrar voltaje adecuado de CD al PowerVerter y capacidad adecuada en amperios horas a los equipos conectados Vea la secci n Selecci n de Bater as en la p gina 12 para obtener m s informaci n 7 Interruptor de Circuitos
9. ANTIA EXPRESA O IMPLICITA INCLUYENDO GARANTIAS DE COMERCIALIZACION Y APTITUD PARA UN PROPOSITO PARTICULAR Algunos estados no permiten limitaciones o exclusiones de garant as impl citas por consiguiente es posible que la s limitaci n es o exclusi n es mencionada s no sea n v lidas para el comprador EXCEPTO COMO SE ESPECIFICA EN ESTE DOCUMENTO TRIPP LITE NO SERA RESPONSABLE EN NINGUN CASO POR DA OS O PERJUICIOS DIRECTOS INDIRECTOS INCIDENTALES O CONSIGUIENTES QUE SURJAN POR EL USO DE ESTE PRODUCTO AUN SI EXISTEN ADVERTENCIAS PREVIAS SOBRE LA POSIBILIDAD DE DICHOS DA OS Espec ficamente Tripp Lite noes responsable por costo alguno como p rdidas de ganancias o r ditos p rdidas de equipos p rdida de uso de equipos p rdida de software p rdida de datos costo de equipos sustitutos reclamos porterceras u otras partes Especificaciones MODELO PV500FC PV1000FC Peso 15 lbs 20lbs INVERSOR Energ a Continua O 20 C 500W 1000W Energ a de Cresta 1000W 2000W Eficiencia Carga Completa Eficiencia Carga Completa 90 90 Minimum DC Fuse Rating 100A 200A Corriente de Entrada de CD VCD Nominal Carga Completa 50A 100A Sin Carga 2 2A 2 2A Entrada Nominalde CD 12VDC 12VDC Rango de Voltaje de Entrada de CD 10 15 VDC 10 15 VDC Voltaje Nominal de Salida 120 VAC 5 120 VAC 5 Frecuencia Nominal de Salida 60 Hz 3 60 Hz 3 O OO O MODEL PV2000FC PV2400FC Pe
10. TRIPP LITE Owner s Manual THE POWER PEOPLE PV 500FC PV 2000FC 1111 W 35th Street PV 1 000FC PV 2400FC Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com PowerVerter Plus 120V 60 Hz Output DC to AC Power Inverters Voltage and Frequency Controlled High Peak Power High Efficiency Espa ol p 9 Your PowerVerter Plus converts DC power from connected batteries into AC power for connected equipment It can provide up to twice its continuous output rating for short periods enabling it to run electrical devices such as motors that have a high power demand at startup Read this manual carefully to learn how to connect operate and maintain your PowerVerter Plus Safety p 2 Installation Operation amp Features p 6 7 Service amp Warranty p 8 Specifications p 8 Diagrams Copyright O 2000 Tripp Lite All rights reserved PowerVerter is a registered trademark of Tripp Lite Safety This manual contains important instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite PowerVerter Systems PowerVerter Location Warnings Install your PowerVerter indoors away from excess moisture or heat dust or direct sunlight Do not attempt to mount your PowerVerter on a vertical surface Leave adequate space around all sides of the PowerVerter for proper ventilation The more power connected equipment draws the more h
11. as bater as deben ser iguales edad voltaje y capacidad en amperios hora y la suma de sus voltajes debe coincidir con el Voltaje Nominal de Entrada del PowerVerter vea las especificaciones e Conexi n a Bater as M ltiples en Paralelo Refi rase al Diagrama 6 p gina 18 para conectar un PV 2000FC 6 2400FC o refi rase al Diagrama 9 en la p gina 19 para conectar un PV 500FC 6 1000FC Utilice este m todo avanzado de conexi n si desea usar el PowerVerter para alimentar cargas de gran tama o por periodos prolongados de tiempo utilizando un banco de bater as Esta conexi n utiliza un aislador de bater as para suministrar energ a proveniente de un banco paralelo de bater as sin desgastar la bater a de su veh culo Si desea utilizar bater as m ltiples conectadas paralelamente el voltaje de cada bater a debe ser igual al Voltaje Nominal de Entrada del PowerVerter vea las especificaciones 3 Utilice cableado de CALIBRE CORTO Y ESPESO para bater as Utilice cables No 4 con los modelos PV 500FC y PV 1000FC utilice cables No 2 0 con los modelos PV 2000FC y PV 2400FC Los cables de conexi n de bater as deben ser de longitud tan corta como sea posible y en ninguna circunstancia m s larga de 10 pies Los cables de calibre corto y espeso limitan la p rdida de voltaje de CD y permiten m xima transferencia de corriente Los bornes o terminales de las bater as deben apretarse aproximadamente a 4 metros Newton para crear una conexi n
12. converting DC power from an attached battery Leave this switch in the OFF position when not using connected equipment to prevent battery drain Indicator Lights 4 LOAD LOW MED HIGH LEDs All models These three lights show the approximate power demand on your PowerVerter Plus LEDs Illuminated Approximate Load Green 0 50 Green amp yellow 51 75 Yellow 76 100 Red 100 125 All three lights off Inverter off Flashing red twice second Overload Flashing red 4 times second Overload Inverter shutdown 5 BATTERY HIGH MED LOW All models These three lights will turn ON in several sequences to show the approximate charge level and voltage of your connected battery bank and alert you to several fault conditions LEDs Illuminated Capacity Green Full Green amp yellow 80 Full Yellow 60 80 Yellow amp red 40 60 Red 20 40 Flashing red twice second 0 20 Flashing red 4 times second 0 Inverter shutdown Other Features 6 DC Input Terminals All models The terminals lug screws or wing nuts secure the wires leading from your external battery or battery system Your battery or battery system must provide your PowerVerter with proper DC voltage and your equipment with an adequate amp hour capacity See Battery Selection section pg 4 for more information 7 Resettable Circuit Breaker All models The circuit breaker protects your PowerVerter against damage due
13. e edad capacidad en amperios hora y tipo Conserve las bater as en un local con buena ventilaci n Gases hidr genos explosivos pueden acumularse cerca de las bater as si la ventilaci n no es adecuada Podr an producirse chispas durante la etapa final de la conexi n de bater as Siempre observe la polaridad correcta al conectar bater as Apriete los bornes o terminales de las bater as para crear una conexi n eficiente y prevenir calentamiento excesivo No permita que objetos for neos entren en contactos con las dos terminales o bornes de entrada de CD No permita que las terminales o bornes entren en contacto entre s o con alg n otro objeto Esto puede causar lesiones corporales severas o da os a su propiedad Advertencias sobre la Conexi n de Equipos No utilice los Sistemas PowerVerter de Tripp Lite en aplicaciones para el soporte de la vida humana donde una falla del Sistema PowerVerter pudiera causar la falla o alterar significativamente el rendimiento del dispositivo de soporte de la vida humana No conecte un supresor de sobretensiones transitorias regulador de voltaje acondicionador de l nea o no break sistema UPS a los recept culos de salida del PowerVerter Advertencias sobre la Operaci n 10 Este PowerVerter no requiere mantenimiento rutinario alguno No abra el PowerVerter en ninguna circunstancia No existen partes interiores que puedan ser reparadas por el usuario Esta unidad contiene voltaje interi
14. eat will be generated by the PowerVerter Do not install the PowerVerter near magnetic data storage media as this may result in data corruption Battery Connection Warnings Your PowerVerter will not operate until batteries are connected Multiple battery systems must be made up of batteries of the same voltage age amp hour capacity and type Keep battery location well ventilated Explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated Sparks may result during final battery connection Always observe proper polarity as batteries are connected Tighten your battery terminals to create an efficient battery connection and prevent excessive heating Do not allow objects to contact the two DC input terminals Do not short or bridge these terminals together Serious injury to property or person could result Equipment Connection Warnings Do not use Tripp Lite PowerVerter Systems in life support applications where a malfunction or failure of a Tripp Lite PowerVerter System could cause failure or significantly alter the performance of a life support device Do not connect a surge suppressor line conditioner or UPS to the output of the PowerVerter Operation Warnings Your PowerVerter does not require routine maintenance Do not open your PowerVerter for any reason There are no user serviceable parts inside Potentially lethal voltages exist within this unit as long as the batteries are connected Dur
15. eficiente y prevenir calentamiento excesivo el conservar los bornes o terminales insuficientemente apretados puede anular la garant a del PowerVerter Los modelos PowerVerter Plus tienen la capacidad para suministrar capacidades de salida mucho m s altas por breves periodos de tiempo La instalaci n de estas unidades debe configurarse para soportar esta demanda breve de alta corriente A n cuando este PowerVerter es un inversor de alta eficiencia su capacidad de salida est limitada por la longitud y el calibre de los cables que conectan el PowerVerter a las bater as 13 Caracteristicas y Operacion Vea el Diagrama 10 p gina 20 para obtener informaci n sobre la ubicaci n de los interruptores luces indicadoras y otras caracter sticas Recept culos 1 Recept culos de CA Todos los modelos Estos recept culos de salida suministran energ a de CA a los equipos conectados Los modelos PV 500FC y PV 1000FC incluyen recept culos tipo NEMA 5 15 y los modelos PV 2000FC y PV 2400FC incluyen recept culos tipo NEMA 5 20 Conecte sus equipos a estos recept culos como lo har a si fueran recept culos de energ a el ctrica pared Observaci n el total de la demanda de energ a de los equipos conectados a los recept culos de salida del PowerVerter no debe exceder la capacidad total del PowerVerter vea las especificaciones en la p gina 16 bajo las denominaciones Energ a Continua y Energ a de Cresta Tambi n tenga
16. en cuenta que estos recept culos no proporcionan conexi n a tierra Interruptores de Encendido Apagado 2 Interruptor OFF ON apagado encendido PV 500FC y PV 1000FC e Coloque este interruptor en la posici n ON encendido para activar el suministro de energ a a los equipos conectados proveniente del inversor PowerVerter de energ a CD suministrada por las bater as Coloque este interruptor en la posici n ON encendido para controlar el PowerVerter a control remoto por medio de un interruptor de encendido apagado suministrado por el usuario e Conserve este interruptor en la posici n OFF apagado para prevenir el desgaste de las bater as cuando no desee utilizar los equipos conectados 3 Interruptor REMOTE OFF ON remoto apagado encendido PV 2000FC y PV 2400FC e Coloque este interruptor de 3 posiciones en la posici n REMOTE remoto para controlar el PowerVerter por control remoto utilizando el PV APS Remote remoto para PV APS de Tripp Lite vendido por separado Coloque este interruptor en la posici n ON encendido para activar el suministro de energ a a los equipos conectados proveniente del inversor PowerVerter de energ a CD suministrada por las bater as e Conserve este interruptor en la posici n OFF apagado para prevenir el desgaste de las bater as cuando no desee utilizar los equipos conectados Luces Indicadoras 4 Luces LO
17. er Wet Cell vented or Gel Cell Absorbed Glass Mat sealed construction are ideal 6 Volt golf cart Marine Deep Cycle or 8D Deep Cycle batteries are also acceptable Selecting Battery Amp Hour Capacity If you plan to connect your batteries to a vehicle s alternator or another charging current Step 1 Add the Wattage Ratings of your connected equipment to determine the Total Wattage Required Step 2 Divide the Total Wattage Required from Step 1 by the PowerVerter s DC input voltage either 12V or 24V see specifications to determine the DC Amperes Required Step 3 Multiply the DC Amperes Required from Step 2 by the number of hours you will want to run your equipment from battery power to determine a Battery Amp Hours Required Rough Estimate Step 4 Compensate for inefficiency by multipling your Battery Amp Hour Required Rough Estimate from Step 3 by 1 2 to determine how many amp hours of battery power from one or several batteries you should connect to your PowerVerter Note that the Amp Hour ratings of batteries are usually given for a 20 hour discharge rate Actual Amp Hour capacities are less when batteries are discharged at faster rates batteries discharged in 55 minutes provide only about 50 of their listed Amp Hour ratings while batteries discharged in 9 minutes provide as little as 30 of their Amp Hour ratings Example A park ranger wants to be able to power emergency lights off of 12V batteries for up to
18. ermediate battery system 1 Connect your PowerVerter s positive DC Terminal directly to a fuse Tripp Lite strongly recommends that you install a recognized UL component fuse block and fuse within 18 inches of the battery The fuse s rating must equal or exceed the Minimum DC Fuse Rating listed in your PowerVerter model s specifications on page 8 2 Choose a battery configuration appropriate to your batteries and PowerVerter model Single Battery Vehicular Connection Refer to Diagram 4 page 18 to connect a PV 2000FC or 2400FC or refer to Diagram 7 on page 19 to connect a PV 500FC or 1000FC Use this basic connection if you plan to use your PowerVerter to power small loads for brief periods of time from a single vehicle battery When using a single battery its voltage must be equal to the voltage of your PowerVerter s Inverter Nominal Input Voltage see specs Series Battery Vehicular Connection Refer to Diagram 5 page 18 to connect a PV 2000FC or 2400FC or refer to Diagram 8 on page 19 to connect a PV 500FC or 1000FC Use this advanced connection if you plan to use your PowerVerter to power small loads for brief periods of time using several low voltage batteries When using multiple batteries in series all batteries must be equal in age voltage and amp hour capacity and the sum of their voltages must be equal to the voltage of your PowerVerter s Inverter Nominal Input Voltage see specs e Parallel Battery Vehicular Connection
19. ing any service work the batteries should therefore be disconnected Do not connect or disconnect batteries while the PowerVerter is operating Dangerous arcing may result Installation Overview 1 Mount PowerVerter Mounting p 3 2 Select Battery ies Battery Selection p 4 3 Connect Battery ies Battery Connection p 5 4 Connect Equipment Outlets p 6 5 Turn PowerVerter On Power Switches p 6 Mounting Optional Recommended for all Vehicular and Marine Applications Due to their size and weight the PowerVerter Plus systems in this manual should be mounted directly to a rigid horizontal surface mounting plate or bracket before battery connection User must supply all fasteners and brackets Turn your PowerVerter and connected equipment OFF before mounting Mounting for the PV 500FC or PV 1000FC See Diagram 1 p 17 e Install four 5mm 8 fasteners A into a rigid horizontal surface using the measurements in the diagram Leave the heads of the fasteners raised slightly above the surface in order to engage the keyhole slots molded into the bottom of the PowerVerter s feet e Place keyhole slots in the PowerVerter s four feet over the four fasteners and slide the PowerVerter forward or backward to secure it Install an L shaped brackets B as shown to permanently hold the PowerVerter in position Mounting for the PV 2000FC or 2400FC See Diagram 2 p 17 e Install two 8 mm 1 4 in fasteners A int
20. iodos breves para el arranque de dispositivos con motores de alta demanda de energ a Lea este manual detenidamente para obtener informaci n sobre la conexi n mantenimiento y operaci n del PowerVerter Plus Seguridad Instalaci n Caracter sticas y Operaci n p 14 15 Mantenimiento y Servicio p 16 Garant a y Especificaciones p 16 Diagramas p 17 20 Copyright 2000 Tripp Lite Propiedad literaria de Tripp Lite Reservados todos los derechos PowerVerter es una marca registrada de Tripp Lite Seguridad Este manual contiene instrucciones y advertencias importantes que deben seguirse durante la instalaci n operaci n y almacenamiento de todos los Sistemas PowerVerter de Tripp Lite Advertencias sobre la Ubicaci n del PowerVerter Instale este PowerVerter bajo techo alejado de humedad y calor excesivo polvo a luz solar directa No intente instalar el PowerVerter en una superficie vertical Conserve suficiente espacio alrededor del PowerVerter para permitir ventilaci n adecuada Cuanto m s alta sea la demanda de energ a de los equipos conectados m s calor generar el PowerVerter No instale el PowerVerter cerca de cintas magn ticas de memoria ya que esto puede resultar en la corrupci n de los datos en la cinta Advertencias sobre la Conexi n de Bater as El PowerVerter no funcionar sin bater as conectadas al mismo Los sistemas de bater as m ltiples deben contener bater as del mismo voltaj
21. la capacidad indicada para determinar que el total de la suma de las capacidades de las bater as de 12V debe ser por lo menos 30 El ndice en vatios es usualmente especificado en el manual de operaci n o en la placa de identificaci n Si este ndice se indica en amperios y no en vatios usted puede calcular el ndice aproximado en vatios multiplicando el ndice indicado en amperios por el voltaje de entrada 120 12 Conexi n de Bater as Los inversores PowerVerter Plus se conectan usualmente a bater as de autom viles cargadas por el alternador del veh culo Las instrucciones siguientes describen varias conexiones automovil sticas posibles Los inversores PowerVerter Plus tambi n pueden conectarse a bancos de bater as cargados por generadores a gas energ a el ctrica viento agua o generadores solares y otras fuentes de energ a de CA Las instrucciones siguientes pueden adaptarse de acuerdo al banco de bater as que desea utilizar Simplemente reemplace el alternador en los diagramas de conexi n con la fuente de energ a disponible El usuario debe determinar el m todo apropiado de conexi n de acuerdo con la fuente de energ a que desea utilizar Nunca intente operar el PowerVerter directamente conectado a un alternador o a otra fuente de energ a siempre conecte un sistema intermediario de bater as entre la fuente de energ a y el PowerVerter 1 Conecte el borne o terminal positiva de CD del PowerVerter directame
22. loque los agujeros en las cuatro patas del PowerVerter sobre los sujetadores y deslice la unidad hacia delante o hacia atr s para asegurarla Instale sujetadores tipo L B como se indica para sujetar en forma permanente el PowerVerter Montaje del PV 2000FC o PV 2400FC Vea el Diagrama 2 p gina 17 e Instale dos sujetadores A de 8 mm 1 4 pulgada en una superficie r gida horizontal de acuerdo con las medidas especificadas en el diagrama Conserve las cabezas de los sujetadores ligeramente sobre la superficie para encajarlas en los agujeros de las dos patas frontales del PowerVerter e Deslice el PowerVerter hacia delante para encajar los sujetadores en los agujeros de las dos patas frontales del sistema Instale dos sujetadores B de 8 mm 1 4 pulgada en la superficie horizontal y atrav s de los agujeros de las patas posteriores del PowerVerter Apriete los tornillos para fijar en forma permanente el PowerVerter Protector contra Salpicaduras Unicamente en los modelos PV 500FC y PV 1000FC Opcional Recomendado para todas las Aplicaciones Mar timas Siempre use separadores para mantener ventilaci n adecuada en aplicaciones para entornos h medos donde sea necesario instalar un protector contra salpicaduras El usuario debe suministrar el protector contra salpicaduras tornillos y separadores Apague el PowerVerter y los equipos conectados al mismo antes de comenzar el proceso de montaje Instalaci n de Protector cont
23. n en Serie de Baterias en Vehiculos PV2000FC o PV 2400FC Vea pagina 13 5 1 representael alternador 5 2 representa la conexi n atierra de la bater a del veh culo 5 3 representa la bater a del veh culo 5 4 representa el fusible X El Voltaje Nominal de Entrada del Inversor del PV Vealas especificaciones Parallel Battery Vehicular Connection PV 2000FC or PV 2400FC See Pg 5 6 1 is the alternator 6 2is abattery isolator 6 3 is the vehicle battery ground 6 4 is the vehicle battery 6 5 are auxiliary vehicle batteries 6 6 is the fuse X Your PV s Nominal Input Voltage See specifications 18 Conexion Paralela de Baterias en Vehiculos PV 2000FC o PV 2400FC Vea p gina 13 6 1 representa el alternador 6 2 representa el aislador de la bater a 6 3 representa la conexi n atierra de la bater a 6 4 representa la bater a del vehiculo 6 5 representa la bater a auxiliar del veh culo 6 6 representa el fusible X El Voltaje Nominal de Entrada del PV Vealas especificaciones Conexi n de Una Bater a en Veh culos PV500FC or PV 1000FC See Pg 5 PV500FC o PV 1000FC Vea p gina 13 Single Battery Vehicular Connection 7 1 representa el alternador 7 1is the alternator 7 2 representa la conexi n atierra de la bater a del veh culo 7 2is the vehicle battery ground 7 3isthe vehicle battery 7 3 representa la bater a del veh culo 7 4isthefuse 7 4representaelfusible
24. ndo el MATERIAL ORIGINAL DE EMBALAJE incluido con la unidad Adjunte una carga describiendo los s ntomas del problema Si el PowerVerter est dentro del periodo de garant a adjunte una copia de su recibo de compra 15 Garantia Limitada Tripp Lite garantiza que sus productos estar n libres de defectos en materiales y mano de obra por un per odo de un a o en EE UU o 120 d as fuera de EE UU a partir de la fecha inicial de compra La obligaci n de Tripp Lite bajo esta garant a est limitada a reparar o reemplazar a sola discreci n de Tripp Lite los productos defectuosos Para obtener servicio bajo esta garant a usted debe obtener un n mero de Autorizaci n de Devoluci n de Material RMA de Tripp Lite o de uno de sus centros autorizados de servicio Los productos defectuosos deben ser enviados con los cargos de transporte pagados a Tripp Lite o a uno de sus centros autorizados de servicio y deben estar acompa ados porunabreve descripci n del problema que ha experimentado el usuario y comprobaci n de fecha y lugar de compra Esta garant a no cubre equipos que hayan sido da ados por accidente negligencia o uso incorrecto o que hayan sido alterados o modificados en forma alguna Esta garant a s lo es v lida para el comprador original quien debe registrar correctamente este producto dentro de los primeros 10 d as a partir delafecha de compra EXCEPTO COMO SE ESPECIFICA EN ESTE DOCUMENTO TRIPP LITE NO EXTIENDE NINGUNA GAR
25. nte a un fusible Tripp Lite recomienda la instalaci n de una caja de fusibles y un fusible certificado por UL a 18 pulgadas o menos de la bater a El ndice del fusible de ser igual o mayor al Indice M nimo de CD del Fusible como se indica en las especificaciones del PowerVerter en la p gina 16 2 Seleccione una configuraci n de bater as apropiada a las bater as que desea utilizar y al modelo de PowerVerter e Conexi n a Una Bater a Automovil stica Refi rase al Diagrama 4 p gina 18 para conectar un PV 2000FC 6 2400FC o refi rase al Diagrama 7 en la p gina 19 para conectar un PV 500FC 6 1000FC Utilice esta conexi n b sica si desea usar el PowerVerter para alimentar cargas peque as por periodos breves utilizando varias bater as de bajo voltaje Si desea utilizar bater as m ltiples conectadas en serie todas las bater as deben ser iguales en edad voltaje y capacidad en amperios hora y la suma de sus voltajes debe coincidir con el Voltaje Nominal de Entrada del PowerVerter vea las especificaciones e Conexi n a Bater as M ltiples en Serie Refi rase al Diagrama 5 p gina 18 para conectar un PV 2000FC 6 2400FC o refi rase al Diagrama 8 en la p gina 19 para conectar un PV 500FC 6 1000FC Utilice este m todo avanzado de conexi n si desea usar el PowerVerter para alimentar cargas peque as por periodos breves utilizando varias bater as de bajo voltaje Si desea utilizar bater as m ltiples conectadas en serie todas l
26. o a rigid horizontal surface using the measurements in the diagram Leave the heads of fasteners raised slightly above the horizontal surface in order to engage the slots in the PowerVerter s two front feet e Slide PowerVerter forward to fully engage the fasteners in the PowerVerter s front feet Install two 8 mm 1 4 in fasteners B into the horizontal surface through the slots in the Power Verter s two rear feet Tighten the screws to permanently hold your PowerVerter in position Splash Guard PV 500FC and PV 1000FC Models Only Optional Recommended for all Marine Applications When adding a splash guard to a PowerVerter for use in a damp environment spacers must be used to maintain a proper ventilation for the inverter User must supply splash guard screws and spacers Turn your PowerVerter and connected equipment OFF before mounting Adding a Splash Guard for the PV 500FC or PV 1000FC See Diagram 3 p 17 e Thread four 4mm 8 sheet metal screws A through four holes in a rigid horizontal splash guard B measuring 175 mm x 225 mm through four 25mm long hollow spacers C and into the four blind holes in the top panel of your PowerVerter Battery Selection Selecting Battery Type Select a battery or system of batteries that will provide your PowerVerter with proper DC voltage and an adequate amp hour capacity Select Deep Cycle batteries to enjoy optimum performance from your PowerVerter Batteries of eith
27. or potencialmente letal mientras las bater as est n conectadas Por esta raz n las bater as deben desconectarse antes de comenzar cualquier proceso de servicio en la unidad No conecte o desconecte bater as durante la operaci n del PowerVerter Esto puede resultar en peligrosos arcos de tensi n S ntesis de Instalaci n 1 Montaje del PowerVerter Montaje p gina 11 2 Selecci n de Bater a s Selecci n de Bater as p gina 12 3 Conexi n de Bater a s Conexi n de Bater as p gina 13 4 Conexi n de Equipos Recept culos p gina 14 5 Encendido del PowerVerter Interruptores de Encendido p gina 14 Montaje Opcional Recomendado para aplicaciones mar timas y automovil sticas Debido a su tama o y peso los sistemas PowerVerter en este manual deben montarse directamente auna superficie r gida horizontal Sujete firmemente la placa o soporte de montaje antes de conectar bater as El usuario debe suministrar todos los sujetadores y soportes necesarios Apague el sistema PowerVerter y los equipos conectados al mismo antes de comenzar el proceso de instalaci n Montaje del PV 500FC o PV 1000FC Vea el Diagrama 1 p gina 17 e Instale cuatro sujetadores A de 5mm No 8 en una superficie r gida horizontal de acuerdo con las medidas especificadas en el diagrama Conserve las cabezas de los sujetadores ligeramente sobre la superficie para encajarlas en los agujeros de las patas del PowerVerter Co
28. ra Salpicaduras para el PV 500FC o PV 1000FC Vea el Diagrama 3 p gina 17 Coloque cuatro tornillos de 4 mm No 8 para chapas met licas A a trav s de cuatro agujeros en un protector r gido horizontal contra salpicaduras B de 175 mm por 225 mm a trav s de cuatro separadores huecos de 25mm C y en los cuatro agujeros ocultos ubicados en el panel superior del PowerVerter da Selecci n de Bater as Tipo de Bater as Seleccione una bater a o sistema de bater as con capacidad adecuada de voltaje de CD y amperios hora para el PowerVerter Seleccione bater as de Ciclo Profundo para obtener rendimiento ptimo del PowerVerter Las bater as de Celdas H medas ventiladas o de Celdas de Gel Fieltro de Vidrio selladas son ideales Las bater as de 6 Voltios para carros de golf mar timas de ciclo profundo o ciclo profundo 8D tambi n son aceptables Capacidad en Amperios Hora Si usted desea conectar las bater as al alternador de su veh culo o a otro tipo de fuente de energ a Paso 1 Sume los Indices en Vatios de los equipos conectados para determinar el Total de Vatios Requeridos Paso 2 Divida el Total de Vatios Requerido obtenido en el Paso 1 entre el voltaje de entrada de CD del PowerVerter 12 24 voltios refi rase a las especificaciones para determinar el Total Requerido en Amperios de CD Paso 3 Multiplique el Total Requerido en Amperios de CD obtenido en el Paso 2 por el n mero de ho
29. ras que desea operar sus equipos con la energ a suministrada por las bater as para determinar el Total Estimado Requerido en Amperios Hora Paso 4 Compense por la deficiencia de las bater as multiplicando el Total Estimado Requerido en Amperios Hora obtenido en el Paso 3 por 1 2 para determinar la capacidad en amperios hora de energ a de las bater as de una o varias bater as que necesita conectar al PowerVerter Tenga en cuenta que los ndices en amperios horas de las bater as usualmente se expresan para un ndice de descarga de 20 horas La capacidad verdadera en amperios hora es menor cuando las bater as se descargan m s r pido las bater as que se descargan en 55 minutos de uso suministran aproximadamente el 50 del ndice indicado en amperios hora Las bater as que se descargan en 9 minutos de uso suministran un m nimo de 30 del ndice indicado en amperios hora Ejemplo Un guarda forestal desea suministrar energ a para luces de emergencia por una hora utilizando bater as de 12V Esta persona divide el total de vatios requeridos por su equipo 150 vatios entre el voltaje de entrada de CD del PowerVerter 12V y multiplica el resultado por 1 hora para obtener el Total Estimado Requerido en Amperios Hora 12 5 Ahora multiplica esta cantidad por 1 2 para compensar la deficiencia y divide el resultado entre 50 o multiplica por 2 ya que las bater as que se descargan en 1 hora solamente suministran aproximadamente 50 de
30. rties or otherwise Specifications MODEL PV 500FC PV 1000FC Weight 15lbs 20lbs INVERTER Continuous power 20 C 500W 1000W Surge power 1000W 2000W Efficiency FullLoad 90 90 Minimum DC Fuse Rating 100A 200A DC Input Current Nominal V DC Full Load 50A 100A NoLoad 22A 22A Nominal DC Input 12VDC 12VDC DC Input Voltage Range 10 15 VDC 10 15 VDC Nominal Output Volts 120 VAC 5 120 VAC 5 Nominal Output Frequency 60 Hz 3 60 Hz 3 TDT MODEL PV2000FC PV2400FC Weight 37lbs 40lbs INVERTER Continuous power 20 C 2000W 2400W Surge power 4000W 4800W Efficiency Full Load 90 90 Minimum DC Fuse Rating 400A 250A DC Input Current Nominal V DC FullLoad 200A 120A NoLoad 2 2A 2 2A Nominal DC Input 12VDC 24VDC DC Input Voltage Range 10 15VDC 20 30 VDC Nominal Output Volts 120 VAC 5 120 VAC 5 Nominal Output Frequency 60 Hz 3 60 Hz 3 Manual de Operaci n TRIPP LITE res PV1000FC PV 2400FC THE POWER PEOPLE 1111 W 35th Street Chicago IL 60609 USA on eee PowerVerter Plus Salida de 120V 60 Hz Inversores Energ a de CD a CA Voltaje y Frecuencia Controlada Alta Energ a de Cresta Alta Eficiencia Este modelo PowerVerter Plus convierte energ a de CD proveniente de las bater as conectadas a energ a de CA para alimentar sus equipos Tiene capacidad para suministrar hasta el doble de su ndice de voltaje de salida por per
31. so 37Ibs 40lbs INVERSOR Energ a Continua 20 C 2000W 2400W Energ a de Cresta 4000W 4800W Eficiencia Carga Completa 90 90 Indice M nimo de CD del Fusible 400A 250A Corriente de Entrada de CD VCD Nominal Carga Completa 200A 120A Sin Carga 2 2A 2 2A Entrada Nominal de CD 12VDC 24VDC Rango de Voltaje de Entrada de CD 10 15VDC 20 30VDC Voltaje Nominal de Salida 120 VAC 5 120 VAC 5 Frecuencia Nominal de Salida 60 Hz 3 60 Hz 3 16 ticos E AD S D WW 7 E S Q E E S a Single Battery Vehicular Connection PV 2000FC or PV 2400FC See Pg 5 4 1is the alternator 4 2is the vehicle battery ground 4 3is the vehicle battery 4 4is the fuse X Your APS s Inverter s Nominal Input Voltage See specifications Conexi n de Una Bater a en Veh culos PV 2000FC o PV 2400FC Vea p gina 13 4 1 representa el alternador 4 2 representa la conexi n a tierra de la bater a del veh culo 4 3 representa la bater a del veh culo 4 4 representa el fusible X El Voltaje Nominal de Entrada del Inversor del APS Vealas especificaciones X 2 Volts X 2 Volts Series Battery Vehicular Connection PV 2000FC or PV 2400FC See Pg 5 5 1is the alternator 5 2 is the vehicle battery ground 5 3is the vehicle battery 5 4 is the fuse X Your PV s Nominal Input Voltage See specifications Conexio
32. to output overload Ifthe breaker trips remove some of the load on the PowerVerter to prevent overload then wait 1 minute to allow components to cool before resetting the circuit breaker 8 Remote On Off Switch Connector PV 500FC and PV 1000FC This jack can be used to connect a user supplied corded on off switch for remote control 9 APS PV Remote Connector PV 2000FC and PV 2400FC This RJ11 jack can be used to connect an optional Tripp Lite APS PV Remote sold seperately to monitor and control the operation of the PowerVerter at a distance See the instructions packed with the APS PV Remote for installation operation and maintenance Maintenance amp Service Maintenance Your PowerVerter model requires no maintenance but should be kept dry at all times Periodically check all cable connections both at the unit and at the battery Clean and tighten connections as necessary Service If returning your PowerVerter to Tripp Lite please pack the PowerVerter carefully using the ORIGINAL PACKING MATERIAL that came with the unit Enclose a letter describing the symptoms of the problem If the PowerVerter is within the warranty period enclose a copy of your sales receipt Limited Warranty Tripp Lite warrants its products to be free from defects in materials and workmanship for a period of one year domestic or 120 days export from the date of initial purchase Tripp Lite s obligation under this warranty is limited to

Download Pdf Manuals

image

Related Search

Related Contents

施工説明書(PDF:15191KB)  Samsung 2400x600dpi 18puslapis/min Daugiafunkcinis spausdintuvas CLX-3305FN Vartotojo vadovas  Bordadora Bsq mod E900  AP400/AP250  Argoclima Hi Floor Design Plus  取扱説明書 埋込収納棚  JVC LYT0190-001B User's Manual  DE SAPIN DE VANCOUVER (Ables grandis)  クリックしてご覧ください [12502KB pdfファイル]  48-Bit TRUE COLOR  