Home

Traulsen UC27WT User's Manual

image

Contents

1. h ig ig Side View Side View Model UR48DT Model UR48DT Showing Built In Installation 4 Showing Free Standing Installation lll INSTALLATION continued lil ELECTRICAL OUTLET INSTALLATION Refer to the diagram below to determine the correct location for the electrical outlet for built in units Bhat 8 4 Electrical Outlet Installation For Model UR48DT 69 49 Wall Opening NOTE Wall location of electrical outlet for built in units and applications that require unit to be counter top depth locate outlet in shaded area only IV MISCELLANEOUS PRODUCT FEATURES IV a SOLAR DIGITAL THERMOMETER All Spacesaver models are equipped with an external solar digital thermometer It has an LED display and is mounted on the top left side of the cabinet next to the louvers Thermometers on older Spacesaver models also in cluded a battery back up for use in low light condi tions Prolonged use of this in low light conditions could result in exhausting the battery To replace the battery back up lift up the louver assembly as out lined in section V a Next remove the screws secur ing the thermometer housing cover and replace the battery IV b LIGHT SWITCHES All Spacesaver models include a concealed light switch mounted in the top door hinge s which auto matically activates the interior light when the door is opened When the door is closed the lights are not
2. The Serial Tag Page 1 V Operation ll Receipt Inspection Page 2 a Adjusting The Temperature Page 6 Ill Installation b Automatic Defrost Page 6 a Location Page 2 b Packaging Page 2 VI Care amp Maintenance c Installing Legs or Casters Page 2 a Cleaning The Condenser Page 6 d Shelf Pins Page 3 b Hinge Replacement Page 6 e Installing The Condensate Evaporator Page 3 c Replacing The Gaskets Page 6 f Remote Installation Page 3 d Cleaning The Exterior Page 7 g Cord amp Plug Page 3 e Cleaning The Interior Page 7 h Power Supply Page 3 f Changing The Interior Light Page 7 i Wiring Diagram Page 3 VII Misc Operations j Clearance Page 3 a Adjusting The Shelves Page 7 k Built In Installation Page 4 b Removing The Drawer Pans Page 7 Electric Outlet Installation Page 5 c Removing The Drawers Page 7 IV Miscellaneous Product Features VIII Other a Solar Digital Thermometer Page 5 a Service Information Page 7 b Light Switches Page 5 b Spare Parts Page 8 c Defogger Control Page 5 c Warranty Registration Page 8 IX Trouble Shooting Guide Page 8 X Warranty Information Page 9 XI Index Page 10 gt The serial tag is a permanently affixed sticker on FORT WORTH TX mPa f 3 which is recorded vital electrical and refrigeration data SERIAL MODEL about your Traulsen product as well as the model VOLTS Hz PH and serial number This tag is located in the upper right interior compartment on all Spacesaver reach TOTAL CURRENT AMPS in refrigerator freez
3. not cover the cost of packing freight or labor such costs being the sole responsibility of the dealer THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED AND CONSTITUTES TRAULSEN S FULL OBLIGATION AND LIABILITY WARRANTIES NOT AVAILABLE ON REMOTE MODELS A Adjusting The Temperature B BTU s Built In Installation c Casters Cleaning The Condenser Cleaning The Exterior Cleaning The Interior Clearance Compressor Hold Down Provisions Compressor Oil Condensate Evaporator Condensing Unit Cord amp Plug D Damage Freight Defogger Control Defrost Automatic Drawer Drawer Pans E Electrical Outlet Location E Fans Freight Claim G Gaskets H Hinge Replacement l Interior Light Installation Built In Installation Recessed J K Keys Door L Legs Lights Interior Light Cover Light Switch Louver Assembly Rw NNOOND ARN oOunNND WHWNWWAAAN XI INDEX 10 N Nylon Netting o Outlet Electrical P Pallet Shipping Pans Drawer Plastic Covering Power Supply R Recessed Installation Refrigerant Remote Installation Return Authorization S Serial Tag Service Agents Shelf Pins Shelves Solenoid Valves I Temperature Adjustment Thermometer CIC Trap I lt Warranty Warranty Registration Wiring Diagram X lt IN WNNND NONA ao OW ONS 4 5 HOURS OF OPERATION Monday thru Fr
4. odor spills use baking soda and water mixed to a 1 TBSP baking soda to 1 pint water ratio VI e CLEANING THE INTERIOR For cleaning both stainless steel and anodized alumi num interiors the use of baking soda as described above is recommended Use on breaker strips and as well as door gaskets All interior fittings are remov able without tools to facilitate cleaning VI f REPLACING THE INTERIOR LIGHT BULB Turn the unit OFF the ON OFF switch is located be hind the top louver panel Next remove the light cover by squeezing the sides together which releases the tabs from the holding slots Replace the burned out light bulb with a similar type appliance bulb To replace the light cover squeeze the sides together and reinsert tabs in to the holding slots and release to lock in place Vil MISC OPERATIONS VII a ADJUSTING THE SHELVES For shelves mounted on pins first select the desired location and remove the white plastic covers in the interior back and sides by rotating them counter clock wise Next remove the existing shelf pins by rotating them counter clockwise Install the pins in the desired location and tighten by rotating clockwise Make sure the pin is securely tightened down don t over tighten Slide the shelf into its new position Replace the white plastic covers into the holes vacated by the shelf pins VII b REMOVING THE DRAWER PANS For your convenience each drawer contains two 2 remov
5. operating In addition an exterior mounted illumin IV b LIGHT SWITCHES cont d ated red switch is included for manual light control Typically this feature is used for units supplied with glass doors Inthe ON position the lights are illumi nated whether the doors are open or not In the OFF position the lights are controlled by the hinge switch as described in the first paragraph IV c DEFOGGER CONTROL As environmental conditions vary condensation may appear on the front of your Spacesaver around the doors To control this Traulsen has included a manual defogger switch which is mounted on the top left side of the cabinet next to the louvers below the thermom eter When in the ON position anti condensate heaters around the door perimeter are activated which help to evaporate any condensation and prevent it from re curring This can be turned OFF when not needed in order to save energy V OPERATION V a ADJUSTING THE TEMPERATURE The refrigeration system has been properly charged and tested at the factory Plug the unit into the power outlet to determine if the compressor s is running If not check the ON OFF switches behind the louver assembly On a refrigerator freezer models UR48DT there are separate switches for each compartment lo cated on the right side and both must be in the ON position If after determining that your Spacesaver unit is func tioning and has had adequate time to
6. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF TRAULSEN SHALL HAVE NO OBLIGATION OR LIABILITY FOR CONSEQUENTIAL OR SPECIAL DAM AGES GROWING OUT OF OR WITH RESPECT TO THE EQUIPMENT OR ITS SALE OPERATION OR USE AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO ASSUME FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT OR ITS SALE OPERATION OR USE OTHER THAN AS STATED HEREIN INTERNATIONAL COMMERCIAL WARRANTY for Canadian warranties see domestic US warranty TRAULSEN amp CO INC warrants to the original purchaser the Refrigeration Equipment manufactured and sold by it to be free from defects in material and workmanship under normal use and service for a period of one 1 year from date of shipment Under this warranty TRAULSEN amp CO INC will reimburse the pur chaser for the replacement of any part of said equipment excluding dryers amp refrigerant gas which then proves to be defective This warranty is void if said equipment or any part thereof has been subject to misuse damage in transit accident negligence or alteration TRAULSEN S standard warranty does not apply to Export Sales Rather for a period of one 1 year from date of original installation not to exceed Fifteen 15 months from date of shipment from factory TRAULSEN will replace F O B factory any defective parts normally subject to warranty will
7. Quality Refrigeration Instructions for the installation operation and maintenance of all Traulsen Spacesaver Models Refrigerator Models UR30HT UR48HT UC27HT Freezer Model UR30LT Refrigerator Freezer Model UR48DT Wine Cabinets UR30WT UR48WT UC27WT This Traulsen unit is built to our highest quality standards We build our refrigerators freezers and heated cabinets this way as a matter of pride This philosophy has made Traulsen the leader in commercial refrig eration since 1938 We thank you for your choice and confidence in Traulsen equipment and we know you will receive many years of utility from this equipment All Traulsen units are placed on a permanent record file with the service department In the event of any future questions you may have please refer to the model and serial number found on the name tag affixed to the unit Should you need service however call us on our toll free number 800 825 8220 between 7 30 am and 4 30 pm CST Monday thru Friday It is our pleasure to help and assist you in every possible way INSTALLER COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION INITIAL START DATE SERIAL NO MODEL TYPE COMPANY INDIVIDUAL NAME INSTALLER FORM NUMBER TR35749 REV 5 03 P N 375 60177 00 TABLE OF CONTENTS MAXIMUM OVERCURRENT PROTECTION LIGHTS WATTS HEATERS AMPS REFRIGERANT TYPE DESIGN PRESSURE HIGH REFRIGERANT TYPE DESIGN PRESSURE HIGH 370 60294 00 REV A LISTED
8. able anodized aluminum pans They can be re moved for cleaning simply by opening the drawer and lifting them out VII c REMOVING THE DRAWERS Prior to removing the drawers food and pans should be removed The drawer is heavy and care should be taken to keep feet clear To remove pull the drawer out as far as possible Then lift the drawer and con tinue to pull until the drawer is free of the unit To replace simply reverse the process Vill OTHER VIII a SERVICE INFORMATION Before calling for service please check the following Is the electrical cord plugged in Is the fuse OK or circuit breaker on Is the power switch ON If there is no air movement in the freezer unit it may be in defrost cycle Wait 35 minutes to see if the unit will restart Do the lights work If after checking the above items and the unit is still not operating properly please contact an authorized Traulsen service agent A complete list of authorized service agents was provided along with your Traulsen unit If you cannot locate this you may also obtain the name of a service agent from the Tech Service page of our website www traulsen com If service is not satisfactory please contact our in house service department at Traulsen amp Co Inc 4401 Blue Mound Road Fort Worth TX 76106 800 825 8220 Traulsen amp Co Inc reserves the right to change speci fications or discontinu
9. age For installing casters the casters are plate type and require the use of four 4 bolts each to secure them firmly to the cabinet bottom at each corner see figure 2 The caster bolts are tightened using a 1 2 socket wrench Threaded Holes Figure 2 Caster lll INSTALLATION continued Ill d SHELF PINS The unit is supplied with shelves and shelf pins in stalled Check all shelf pins to assure they are tight ened down as they may have come loose during ship ping Rotate the pins clockwise until they are secured against the side of the cabinet Ill e INSTALLING THE CONDENSATE EVAPORATOR A bottom mounted electric condensate evaporator is normally supplied on all self contained models This is shipped in a cardboard carton secured to the cabi net interior and must be installed prior to use To install a bottom mounted electric condensate evaporator see figure 3 After the cabinet has been uncrated and the legs cast ers attached locate the four 4 holes on the exterior bottom towards the rear of the cabinet Then using the four 4 screws provided attach the mounting rails to the cabinet bottom the end flange is to be up and be facing towards the cabinet rear Next place the heater into the heater bracket note the enclosed springs are only to be used when the heater is placed on the floor Slide heater and bracket into the mount ing rails Plug the supplied cord into both the heater on
10. air flow at the back of the unit Clear ance of at least 12 above is required in order to per form certain maintenance tasks Ill INSTALLATION continued lll k BUILT IN INSTALLATION Select a proper location for your unit away from ex treme heat or cold Due to the unique air flow of the unit the Spacesaver can be built in or used as a free standing unit Allow enough clearance between the unit and side wall so that the doors can be opened a minimum of 90 degrees The floor should be level firm and capable of supporting the weight of the fully loaded unit Follow the typical installation instructions outlined in Section Ill a thru Ill j as required UIN V8 All built in units require a minimum of 1 2 clearance around the cabinet for servicing see figure 5 If top clearance exceeds 1 the unit must be blocked per the free standing instructions of Figure 6 NOTE If a self contained unit is to be installed com pletely recessed the front louvers must NOT be q E blocked or replaced with a solid panel The front lou vers allow good air circulation in the compressor com BMCE partment e Fig 4 Front View Model UR48DT Showing Minimum Built In Clearances BLOCK Te OLL one in each come tb lol U Ivi E IRI s
11. e carrier and file a freight claim Under no condition may a damaged unit be re turned to Traulsen amp Co without first obtaining writ ten permission return authorization lll INSTALLATION Ill a LOCATION Select a proper location for your Traulsen Spacesaver unit away from extreme heat or cold Allow enough clearance between the unit and the side wall so that the door s may open a minimum of 90 Ill b PACKAGING All Traulsen Spacesaver units are shipped from the factory bolted to a sturdy wooden pallet and packaged in a durable cardboard container The carton is at tached to the wooden skid with the use of large staples These should first be removed to avoid scratching the unit when lifting off the crate To remove the wooden pallet first if at all possible we suggest that the cabinet remain bolted to the pallet during all transportation to the point of final installa tion The bolts can then be removed with a 3 4 socket wrench Avoid laying the unit on its front side or back for removal of the pallet All exterior metal surfaces are protected from scratch ing during manufacturing and shipping by a plastic covering This should be removed prior to installa tion NOTE Traulsen does not recommend laying the unit down on its front side or back However if you must please be certain to allow the unit to remain in an up right position afterwards for 24 hours before plugging it in so that the compressor
12. e models without notice VIII OTHER cont d VIII b SPARE PARTS Spare or replacement parts may be obtained through a parts supplier or one of our authorized service agents A complete list of authorized service agents accompanies this manual and is also posted on our company s official website www traulsen com VIII c WARRANTY REGISTRATION For your convenience the warranties on your new Traulsen unit may be registered with us by one of two methods Completing the enclosed warranty card shipped with the unit or by filling out the on line warranty registration form located on the Technical Service page of our website www traulsen com IX TROUBLE SHOOTING GUIDE FIND YOUR PROBLEM HERE REMEDY 1 Condensing unit fails to start Check if line has been disconnected Check switch behind louvers 2 Condensing unit operates for Are doors closing properly prolonged periods or continuously A Dirty condenser or filter Clean properly Evaporator coil iced Needs to defrost 3 Food compartment is too warm Thermostat setting too high readjust thermostat Check door gasket for proper seal Frequent door openings allow adequate recovery time Perhaps a large quantity of food has recently been added or the door was kept open for a long period of time in both cases allow adequate time for the cabinet to recover its normal operating temperature 4 Food compartment is too cold i Adjust the thermostat to a warm
13. er setting 5 Condensation on the exterior surface Condensation on the exterior surface of the unit is perfectly normal during periods of high humidity Turn on the defogger switch Check door alignment and gaskets for proper seal 6 Compressor hums but does not start Call service 7 Light bulb is not functioning Check if light bulb is burned out Check to see if light switch is on if applicable X WARRANTY INFORMATION STANDARD DOMESTIC WARRANTY TRAULSEN amp CO INC warrants new equipment to the original purchaser when installed within the United States against defective material and workmanship for one 1 year from the date of original installation Under this warranty TRAULSEN amp CO INC will repair or replace at its option including service and labor all parts found to be defective and subject to this warranty The compressor part is warranted for an additional four 4 years During this period TRAULSEN amp CO INC will supply re placement compressor s if deemed defective however all installation recharging and repair costs will remain the responsibility of the owner This warranty does not apply to damage resulting from fire water burglary accident abuse misuse transit acts of God attempted repairs improper installation by unauthorized persons and will not apply to food loss THERE ARE NO ORAL STATUTORY OR IMPLIED WARRANTIES APPLICABLE TO TRAULSEN INCLUD ING BUT NOT LIMITED TO
14. er and undercounter models MINIMUM CIRCUIT AMPS AMPS READING THE SERIAL TAG OZ e Serial The permanent ID of your Traulsen LOW Model The model of your Traulsen e Volts Voltage OZ e Hz Cycle LOW PH Phase e Total Current Maximum amp draw e Minimum Circuit Minimum circuit ampacity e Lights Light wattage e Heaters Not applicable for Spacesaver models e Refrigerant Refrigerant type used e Design Pressure High amp low side operating pressures and refrigerant charge e Agency Labels Designates agency listings ll RECEIPT INSPECTION All Traulsen products are factory tested for perfor mance and are free from defects when shipped The utmost care has been taken in crating this product to protect against damage in transit All interior fittings have been carefully secured and the legs or casters and bottom mounted condensate evaporator are boxed and strapped inside to prevent damage If the unit is equipped with optional locks the door keys will be at tached to the handle with a nylon strip The handle is protected by an easily removable nylon netting You should carefully inspect your Traulsen unit for damage during delivery If damage is detected you should save all the crating materials and make note on the carrier s Bill Of Lading describing this A freight claim should be filed immediately If damage is sub sequently noted during or immediately after installa tion contact the respectiv
15. iday 7 30 am 4 30 pm CST Traulsen 4401 Blue Mound Road Fort Worth TX 76106 Phone 800 825 8220 Fax Svce 817 740 6757 Website www traulsen com Quality Refrigeration 2003 Traulsen All Rights Reserved
16. lied with a cord amp plug attached It is shipped coiled at the top of the cabinet secured by a nylon strip For your safety and protection all units supplied with a cord and plug in clude a special three prong grounding plug on the ser vice cord Select only a dedicated electrical outlet with grounding plug for power source NOTE Do not un der any circumstances cut or remove the round grounding prong from the plug or use an extension cord lil h POWER SUPPLY It is recommended that the supply voltage be checked prior to connection to be certain that proper voltage for the cabinet wiring is available refer to the serial tag to determine correct unit voltage Make connec tions in accordance with local electrical codes Use qualified electricians Use of a separate dedicated circuit is recommended Size wiring to handle indicated load and provide nec essary overcurrent protector in circuit lll i WIRING DIAGRAM Refer to the wiring diagram for any service work per formed on the unit Should you require one please contact Traulsen Service at 800 825 8220 and pro vide the model and serial number of the unit involved lll j CLEARANCE In order to assure optimum performance the condens ing unit of your Traulsen unit MUST have an adequate supply of air for cooling purposes Therefore the operating location must either have a minimum of 12 clearance overhead of the condensing unit or allow for unrestricted
17. oils and refrigerant may settle lll INSTALLATION continued Ill c INSTALLING LEGS OR CASTERS 6 high stainless steel legs are supplied standard for all Traulsen Spacesaver units Casters in lieu of legs are available as an optional accessory for the same models These are shipped from the factory packed inside a cardboard box which is strapped to one of the shelves Remove the nylon strap and open the box it should contain either four 4 legs or four 4 casters and sixteen 16 bolts WARNING THE CABINET MUST BE BLOCKED AND STABLE BEFORE INSTALLING LEGS OR CASTERS To install the legs or casters first raise and block the unit a minimum of 7 from the floor For installing legs thread the legs into the threaded holes on the bottom of the cabinet see figure 1 Be certain that all legs are tightly secured legs and casters should be tightened to 300 inch pounds max When the unit is set in its final position it is important for proper op eration that the unit be level The legs are adjustable for this purpose turn the bottom of the leg counter clockwise to raise it clockwise to lower it Level the unit from front to back as well as side to side in this manner using a level placed in the bottom of the cabi net enum re i le 1 Please note that Traulsen Spacesaver units are not de signed to be moved while on legs If the unit requires moving a pallet jack or forklift should be used to pre vent dam
18. one end and the electrical outlet provided on the cabinet exterior bottom towards the front on the other Screw the U Trap UR30LT only or 90 degree elbow joint all other Spacesaver models into the drain line located on the rear of the cabinet and then screw the drain extension into the U Trap or elbow joint U Trap Electric Heater Drain Extension 10 32 x 3 8 Screw 4 Mounting Rails Heater Bracket Figure 3 A remote model is normally configured for conden sate to be run to a floor drain unless purchased with a condensate evaporator The installer is responsible for making the required extension to the floor drain in accordance with good practice and local regulations The bottom mounted electric condensate evaporator of your Traulsen Spacesaver should be cleaned occa sionally to keep it clear of dirt and debris lll f REMOTE INSTALLATION Remote models are supplied without compressors solenoid valves etc The correct voltage amp listing refrigerant and BTU s are listed on the unit s serial tag It is the responsibility of the installer to specify and supply the correct size compressor s based upon this information and on site requirements Refrigerant line installation must be done in adhering to good prac tice and local regulations See section Ill e for in formation concerning condensate removal for remote models lll g CORD amp PLUG Most self contained models are supp
19. pull down tem perature the temperature is above below standard ranges 34 to 38 F for refrigerators 0 to 5 F for freez ers adjust the temperature controls This is a black knob located behind the louver assembly along the centerline It can be adjusted up or down one number at a time to raise or lower temperature Fig 7 SC SSX Remove Screws RX SX Fig 8 Lift Up Louver Assembly V b AUTOMATIC DEFROST The refrigerator section operates on a cycle defrost basis which means at the end of each refrigeration cycle the coil is allowed to reach 42 F and defrost itself This method allows for maximum efficiency of the refrigeration system The freezer section is normally frost free and never requires a manual defrost When the defrost system is operating the compressor and fans do not run WARNING DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING ANY PARTS OF THE UNIT VI CARE amp MAINTENANCE VI a CLEANING THE CONDENSER The most important thing you can do to insure a long reliable service life for your Traulsen is to regularly clean the condenser coil The condensing unit requires regularly scheduled cleaning to keep the finned condenser clean of lint and dust accumulation The frequency of cleaning will depend on jobsite conditions however at least once a month is strongly recommended Keeping the condenser clean allows the cabinet to opera
20. te more efficiently and use less energy To clean the condenser first disconnect electrical power to the cabinet and lift up the front louver as sembly To lift this remove the two screws located on both sides at the bottom of the louver assembly see figure 7 Once the screws are removed the panel can be pivoted upwards allowing full access to the front facing condenser see figure 8 Vacuum or brush any dirt lint or dust from the finned condenser coil the compressor and other cooling system parts If significant dirt is clogging the condenser fins use compressed air to blow this clear Care should be taken not to bend any of the condenser fins as this will reduce performance and compressor life Lower louver assembly and replace the screws to hold it in place VI b HINGE REPLACEMENT Both the door and hinge can be easily removed from the cabinet To remove the door remove the screw at the bottom of the upper hinge Inside the upper hinge there is a small pin screw which secures the door in place Remove this with a flat head screwdriver and the door can then be lifted off the hinge To remove the door half of the hinge from the door slide hinge cover downward and then remove the three Phillips head screws which secure the hinge in place on the door To remove the cabinet half of the hinge remove the three Phillips head screws which hold it in place On all units the top hinge s contains a microswitch for controlling
21. the interior lighting To reassemble the hinge reverse the previous proce dure VI c REPLACING THE GASKETS To remove the gasket to be replaced grasp it firmly by one corner and pull it out Before attempting to install a new gasket both the unit and the gasket it self must be at room temperature Insert the four cor ners first by using a rubber mallet or hammer with a block of wood After the corners are properly inserted work your way towards the center from both ends by VI CARE amp MAINTENANCE cont d VI c REPLACING THE GASKETS cont d gently hitting with a mallet until the gasket is com pletely seated in place see figure 9 for proper gasket placement Inside Door Panel Gasket Assembly Fig 9 Vertical Gasket Retainer NOTE The gasket may appear too large but if it is installed as indicated above it will slip into place VI d CLEANING THE EXTERIOR Exterior stainless steel should be cleaned with warm water mild soap and a soft cloth Apply with a damp ened cloth and wipe in the direction of the metal grain Avoid the use of strong detergents and gritty abra sive cleaners as they may tend to mar and scratch the surface Do NOT use cleansers containing chlorine this may promote corrosion of the stainless steel Care should also be taken to avoid splashing the unit with water containing chlorinated cleansers when mopping the floor around the unit For stubborn