Home
Transition Networks SPOEB10XX-100 User's Manual
Contents
1. 2007 Stephen Anderson Vice President of Engineering Date 5 Is data being passed through the device NO e Ensure the Powered Device PD IEEE 802 3af compliant e Ensure the load to the Powered Device PD is less than 0 4 Amp e Is a data source connected if not connect a data source to the media converter e Is the data source active if not start sending data e Are the FX and TX LACT LEDs flashing e Contact Technical Support 1 800 466 4526 then press 2 14 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 techsupport transition com Click the Transition Now link for a live Web chat 15 SPOEB10xx 1xx Compliance Information CISPR22 EN55022 Class A CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital app
2. Fi PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telephone network Der Anschluss dieses Ger tes an ein ffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verst sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformit t Trademark Notice All registered trademarks and trademarks are the property of their respective owners Copyright Restrictions 2004 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks 16 Printed in the U S A 33343 E
3. Rate 10 100 Mb s Packet Size Max 1522 bytes Mac Address 2K Dimensions 3 25 x 1 x 4 8 82 mm x 25 4mm x 120mm Weight 0 8 Ibs 362 g approximately Power Consumption 20 watts maximum Power Supply 48VDC 0 67A external wall mount adapter Output Voltage 0 35A 48VDC 16 8W Environment Tmra 0 to 40 C 32 to 104 F Storage Temp 25 to 85 C 13 to 185 F Humidity 5 to 95 non condensing Altitude 0 to 10 000 feet MTBF 49 981 MIL217F2 Hours 132 144 Bellcore Hours Warranty Lifetime Manufacturer s rated ambient temperature Note The information in this user s guide is subject to change For the most up to date information on the SPOEB10xx 100 media converter view the user s guide on line at www transition com Product is certified by the manufacturer to comply with DHHS Rule 21 CFR Subchapter J applicable at the date of manufacture WARNING Visible and invisible laser radiation when open Do not stare into the beam or view the beam directly with optical instruments Failure to observe this warning could result in an eye injury or blindness WARNING Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure WARNING If the media converter is an IEEE802 3 2005 Powered Device PD capable of receiving power via the Media Dependent Interface MDI leads the power source connector and cabling attached to the barrel power conn
4. act Us Technical Support Technical support is available 24 hours a day U S A and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Chat live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web Based Seminars Transition Networks provides seminars via live web based training Log onto www transition com and click the Learning Center link E Mail Ask a question anytime by sending an e mail to our technical support staff techsupport transition com Address Transition Networks 6475 City West Parkway Minneapolis MN 55344 U S A telephone 952 941 7600 toll free 800 526 9267 fax 952 941 2322 TRANSITION Declaration of Conformity ne NETWORKS e Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 U S A Model SPOEB10xx 1xx Series Media Converters Part Number s SPOEB 1011 100 SPOEB 1013 100 SPOEB 1014 100 SPOEB 1015 100 SPOEB 1016 100 SPOEB 1017 100 SPOEB 1035 100 SPOEB 1029 100 SPOEB 1029 101 Regulation EMC Directive 89 336 EEC Purpose To declare that the SPOEB10xx 1xx to which this declaration refers is in conformity with the following standards CISPR22 1993 EN55022 1994 A1 1995 A2 1997 Class A FCC Part 15 Subpart B UL1950 21 CFR Subpart J the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s PS ee ee ey August
5. allows using Link Loss Notification in both directions CAUTION Associated Ethernet wiring shall be limited to inside the building Installing fiber cables 1 Locate a 100Base FX fiber cable with male two stranded TX to RX connectors installed at both ends 2 Connect the fiber cables to the SPOEB10xx 100 media converter as described e Connect the male TX cable connector to the female TX port e Connect the male RX cable connector to the female RX port 3 Connect the fiber cables to the other device another media converter hub etc as described 6 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Installation Continued Install the fiber cable continued e Connect the male TX cable connector to the female RX port e Connect the male RX cable connector to the female TX port o Device Device Install the copper cable 1 Locate 100Base TX copper cables with male RJ 45 connectors installed at both ends 2 Connect the RJ 45 connector at one end of the cable to the RJ 45 port on the media converter 3 Connect the RJ 45 connector at the other end of the cable to the RJ 45 port on the other device wireless access point VoIP phone network camera etc on the media on the other device converter switch work station etc Connecting power 1 Connect the barrel connector on the power adapter to the power port on the media converter back panel 2 Connect th
6. ans ONE HOne SPOEB10xx 100 User s Guide e Stand Alone Media Converter e Power Over Ethernet e 10 100Base TX to 100Base FX The SPOEB10xx 1xx Power over Ethernet POE is a two port 10 100Base TX to 100Base FX media converter capable of providing power to Data Terminal Equipment DTE Power Devices PD via the Media Dependent Interface MDI twisted pair cable The SPOEB10xx 100 emulates Power Sourcing Equipment PSE and provides power via the 10 100Base TX interface for a remote PD device that complies with the IEEE802 3af standard Part Number Port One Copper Port Two Duplex Fiber Optic 10 100Base TX 100Base FX SPOEB1011 100 RJ 45 ST 1300 nm multimode 100 m 328 ft 2 km 1 2 miles SPOEB1013 100 RJ 45 SC 1300 nm multimode 100 m 328 ft 2 km 1 2 miles SPOEB1014 100 RJ 45 SC 1310 nm single mode 100 m 328 ft 20 km 12 4 miles SPOEB1015 100 RJ 45 SC 1310nm single mode 100 m 328 ft 40 km 24 9 miles SPOEB1016 100 RJ 45 SC 1310 nm single mode 100 m 328 ft 60 km 37 3 miles SPOEB1017 100 RJ 45 SC 1550 nm single mode 100 m 328 ft 80 km 49 7 miles SPOEB1035 100 RJ 45 SC 1310 nm single mode 100 m 328 ft 120 km 74 6 miles Cable distances are the typical maximum distances Actual distance is dependent upon the physical characteristics of the network installation Installation 3 Operation 0 9 Cable Specifications 10 Techni
7. aratus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada European Regulations Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkstdrungen auftreten In diesem Fall ist der Benutzer f r Gegenma nahmen verantwortlich Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors l utilsateur de prende les measures sp cifiques appropri es In accordance with European Union Directive 2002 96 EC of the European Parliament and of the Council of 27 January 2003 Transition Networks will accept post usage returns of this product for proper disposal The contact information for this activity can be found in the Contact Us portion of this document _o aay CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE
8. cal Specifications 12 Troubleshooting 13 Contact US 4 s 00c e ees 15 Compliance Information 16 SPOEB10xx 1xx Part Number Port One Copper Port Two Duplex Fiber Optic 10 100Base TX 100Base FX Single fiber Installed in pairs SPOEB1029 100 RJ 45 SC 1310Tx 1550Rx nm single mode 100 m 328 ft 20 km 12 4 miles SPOEB1029 101 RJ 45 SC 1550Tx 1310Rx nm single mode 100 m 328 ft 20 km 12 4 miles Cable distances are the typical maximum distances Actual distance is dependent upon the physical characteristics of the network installation Optional Accessories sold separately Part Number Description WMBL Wall Mount Bracket Length 4 0 in 102 mm fits converter length 4 7 in 179 mm WMBD DIN Rail Mount Bracket Length 5 0 in 127 mm WMBV Vertical Wall Mount Plate Length 5 0 in 127 mm 2 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Installation CAUTION All installation and service must be performed by qualified service personnel Read and follow all warning notices and instructions marked on the product and included in this manual Set the configuration switches The configuration switches are located on the side panel of switch the SPOEB10xx 100 media converter Use a small flat Key blade screwdriver to set the switches Up Down 8 Position Switch o Eight position con
9. crews and pull the cover off the media converter 2 Locate the 3 header connects J2 J3 and J4 LED Description 2 Set jumpers 2 3 and 4 to the same side either S or U See diagram below PWR Green Power ON Fiber LACT Green ON Link Blinking activity Fiber DPX Green ON Full OFF Half Mode A Mode B TP LACT Green ON Link Blinking activity eaten y fo ae TP SPD Green ON 100Mb s OFF 10Mb s TP DPX Green ON Full OFF Half Blinking collision TP ON PSE Green ON Enabled OFF Disable TP ERR PSE Yellow OFF no problems detected Faults e Yellow ON solid main power is over or under voltage O n e Blink 1 times per sec no signature detected e Blink 2 times per sec overload while applying power e Blink 3 times per sec short circuit detected e Blink 4 times per sec multiple problems detected TP means twisted pair 8 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 techsupport transition com Click the Transition Now link for a live Web chat SPOEB10xx 1xx Cable Specifications The cable s physical characteristics must meet or exceed IEEE 802 3 specifications Copper cable Category 5 Minimum Requirement Gauge Attenuation 24 to 22 AWG 22 0 dB 100m 100 MHz e Straight through OR crossover twisted pair cable may be used e Shielded twisted pair STP OR unshi
10. devices of a link loss If the fiber RX signal is lost on the far end converter the converter will automatically generate a far end fault signal and send it on its TX fiber port to notify the near end converter of the fiber link loss Link Pass Through will then disable the copper link on both ends alerting both end devices of network trouble See diagram below original fault on the fiber link R ESS i P n i Near End Media Media Far End L Device Converter A Converter B J 1 Device i media converter A Far End Fault media converter B disables the copper link signal is sent disables the copper link e Both end devices are notified automatically of the link loss e Prevents loss of valuable data transmitted unknowingly over invalid link e Allows quick diagnosis and resolution of network problem Transition Networks media converters that include the FEF feature will work with other network devices that support Far End Fault per IEEE standards Automatic Link Restoration always enabled Transition Networks s converters will automatically re establish the link in all network conditions e Without a device reset the converters will automatically re establish the link when connected to switches after a link loss e With Auto Negotiation enabled automatic link restoration allows using Auto Negotiation with Link Loss Notification e With Link Pass Through enabled in both directions automatic link restoration
11. e power adapter plug to AC power Verify that the converter is powered by observing the illuminated LED power indicator light on the front panel Note Ifan under or over voltage condition is detect on the main power input the error LED will turn ON This means that the LED will stay ON even if the voltage returns to a valid level This condition indicates a problem with the power supply adapter therefore the power supply adapter should be replaced techsupport transition com Click the Transition Now link for a live Web chat 7 SPOEB10xx 1xx Installation Continued Operation Power over Ethernet PoE Status LEDs The SPOEB10xx 1xx media converter transmits electrical power along with The SPOEB10xx 100 media converter front panel is shown below data to remote devices over standard twisted pair cable in an Ethernet network There are two modes of transmitting 48VDC PoE as defined in IEEE 802 3af Mode A uses pins 1 amp 2 3 amp 6 to transmit data and power Mode B uses pins 4 amp 5 RO TX RX LACT POE 7 amp 8 to transmit power These are the spare pairs in 10BASE T and 100BASE TX acO ff Teon device configurations therefore Mode B requires a 4 pair cable O O DPX C DPX ERO Lo To set A or B PoE Mode do the following 100Bas e FX 10 100Base TX 1 Remove the 4 s
12. ector must meet the isolation requirement specified in IEEE802 3 2005 Failure to observe this warning could result in an electrical shock IMPORTANT Copper based media ports e g Twisted Pair TP Ethernet USB RS232 RS422 RS485 DS1 DS3 Video Coax etc are intended to be connected to intra building inside plant link segments that are not subject to lightening transients or power faults Copper based media ports e g Twisted Pair TP Ethernet USB RS232 RS422 RS485 DS1 DS3 Video Coax etc are NOT to be connected to inter building outside plant link segments that are subject to lightening transients or power faults Failure to observe this caution could result in damage to equipment MTBF is estimated using the predictability method This method is based on MIL 217F at 25 C ambient temperature typical enclosure heat rise of 10 C and nominal operating conditions and parameters Installation and configuration specific MTBF estimates are available upon request Contact Technical Support 12 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Troubleshooting If the media converter fails isolate and correct the fault by determining the answers to the following questions and then take the indicated action 1 Is the media converter power LED ON NO e Is the barrel connector fully inserted into the media converter e Is the adapter plugged into an AC outlet if not plug it into the out
13. elded Twisted pair UTP may be used e Pins 1 amp 2 and 3 amp 6 are the two active pairs in an Ethernet network e RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD e Use only dedicated wire pairs for the active pins e g blue white amp white blue orange white amp white orange etc Straight Through Cable Twisted Pair 1 _ 4 oO Twisted Pair 2 __ 1 2 aw Crossover Cable Twisted Pair 1 5 3 3 Twisted Pair 2 __ 6 6 e Do not use flat or silver satin wire Fiber cable Bit Error Rate Single mode fiber recommended Multimode fiber recommended Multimode fiber optional SPOEB1011 100 DC Powered Fiber optic Transmitter Power Fiber optic Receiver Sensitivity Link Budget SPOEB1013 100 DC Powered Fiber optic Transmitter Power Fiber optic Receiver Sensitivity Link Budget SPOEB1014 100 DC Powered Fiber optic Transmitter Power Fiber optic Receiver Sensitivity Link Budget lt 0 9 um 62 5 125 um 100 140 85 140 50 125 um 1300 nm multimode min 19 0 dBm max 14 0 dBm min 30 0 dBm max 14 0 dBm 11 0 dB 1300 nm multimode min 19 0 dBm max 14 0 dBm min 30 0 dBm max 14 0 dBm 11 0 dB 1310 nm single mode min 15 0 dBm max 8 0 dBm min 31 0 dBm max 8 0 dBm 16 0 dB 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SPOEB1015 100 DC Powered Fiber o
14. fiber RX receive link drops with the HTO PSE LTP switch in the enable position down the PSE power will turn OFF for two seconds then turn back ON to re start the remote device The power will PSE LPT Enabled remain ON to allow the remote PD to re establish the link with the media converter 8 Not Used F U Additional features Link Pass Through always enabled The Link Pass Through allows the media converter to monitor both the fiber and copper RX receive ports for loss of signal In the event of a loss of an RX signal on one media port the media converter will automatically disable the TX transmit signal of the other media port thus passing through the link loss The far end device is automatically notified of the link loss which prevents the loss of valuable data unknowingly transmitted over an invalid link See diagram below media converter A media converter B loses the fiber RX link disables the fiber TX link Near E nd Device Media O Converter A j2 Fa r E nd media converter B disables the copper link original fault on the copper link techsupport transition com Click the Transition Now link for a live Web chat SPOEB10xx 1xx Installation Continued Far End Fault always enabled This troubleshooting feature generally used in conjunction with Link Pass Through to notify both end
15. figuration switch SW1 Auto Negotiation TP SW2 Speed TP SW3 Duplex TP SW4 Duplex Fiber SW5 AutoCross TP SW6 PSE power SW7 PSE LPT power SW8 Not used 1 Auto Negotiation Up Enables Auto Negotiation 1 Down Disables Auto Negotiation The Auto Negotiation feature allows the media AUO Negotation Enabled converter to bring up the copper links to the highest speed and mode possible for all the o attached network devices Auto Negotiation Disabled techsupport transition com Click the Transition Now link for a live Web chat SPOEB10xx 1xx Installation continued Eight position configuration switch continued 2 Speed Up Forces 100 Mb s on the copper port Down Forces 10 Mb s on the copper port Only when Auto Negotiation is disabled 3 TP Full Half Duplex Up Full Duplex the twisted pair cable distances are constrained by the cable requirements Down Half Duplex the twisted pair cable distances are constrained by the 512 Bit Rule Only when Auto Negotiation is disabled 4 Fiber Full Half Duplex Up The cable distances for the fiber port are constrained by the cable requirements Down The cable distances for the fiber port are constrained by the 512 Bit Rule 5 AutoCross Up Enables the AutoCross function Down Disables the AutoCross function The AutoCross feature allow
16. let e Is the AC outlet active if not check the outlet s circuit beaker e Contact Technical Support 1 800 466 4526 then press 2 YES e Proceed to step 2 2 Is the POE LED ON NO e Is there an active connected to anther device RJ 45 cable inserted into the media converter s TX port if not insert the cable accordingly Is the power turned ON to the other device e Contact Technical Support 1 800 466 4526 then press 2 YES e Go to step 3 3 Is the TX LACT LED ON NO e Check the twisted pair cables for proper installation in the device at both ends e Disconnect and reconnect the twisted pair cable to restart the initialization process e Restart the attached device to restart the initialization process e Check that the AutoCross switch is in the UP position enabled e Contact Tech Support 1 800 260 1312 YES e Goto step 4 4 Is the FL LINK LED ON NO e Check the fiber cables for proper connection e Verify that the TX and RX cables on the media converter are connected to the RX and TX ports respectively on the other device e Disconnect and reconnect the fiber cable to restart the initialization process e Restart the attached device to restart the initialization process e Contact Tech Support 1 800 260 1312 YES e Proceed to step 5 techsupport transition com Click the Transition Now link for a live Web chat 13 SPOEB10xx 1xx Troubleshooting continued Cont
17. ptic Transmitter Power Fiber optic Receiver Sensitivity Link Budget SPOEB1016 100 DC Powered Fiber optic Transmitter Power Fiber optic Receiver Sensitivity Link Budget SPOEB1017 100 DC Powered Fiber optic Transmitter Power Fiber optic Receiver Sensitivity Link Budget SPOEB1035 100 DC Powered Fiber optic Transmitter Power Fiber optic Receiver Sensitivity Link Budget SPOEB1029 100 DC Powered SPOEB1029 101 DC Powered Fiber optic Transmitter Power Fiber optic Receiver Sensitivity Link Budget The fiber optic transmitters on this device meet Class Laser safety requirements Cable Specifications Continued 1310 nm multimode min 8 0 dBm max 2 0 dBm min 34 0 dBm max 7 0 dBm 26 0 dB 1310 nm multimode min 5 0 dBm max 0 0 dBm min 34 0 dBm max 7 0 dBm 29 0 dB 1550 nm single mode min 5 0 dBm max 0 0 dBm min 34 0 dBm max 7 0 dBm 29 0 dB 1310 nm multimode min 0 0 dBm max 5 0 dBm min 36 0 dBm max 3 0 dBm 36 0 dB 1310Tx 1550Rx nm single mode 1550Tx 1310Rx nm single mode min 13 0 dBm max 6 0 dBm min 32 0 dBm max 3 0 dBm 19 0 dB per IEC 825 CDRH standards and comply with 21 CFR1040 10 and 21CFR1040 11 techsupport transition com Click the Transition Now link for a live Web chat 11 SPOEB10xx 1xx Technical Specifications For use with Transition Networks Model SPOEB10xx 100 or equivalent Standards IEEE 802 3 IEEE 802 3af Data
18. s either straight through MDI or crossover MDI X cables to be used when connecting to 100Base TX devices such as wireless access point VoIP phone network camera etc AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up regardless of the cable configuration JA TULL TP 100Mb s Enabled TP 10Mb s Enabled TP Half Duplex Fiber Full Duplex Cel LLU Fiber Half Duplex gt utoCross Enabled AutoCross Disabled 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Installation Continued Eight position configuration switch continued 6 PSE Power Up Enables PSE power J Down Disables PSE power PSE Enabled The IEEE 802 3af standard allows a device to provide power PSE Power Sourcing Equipment ld to a remote device and for a remote device PD LILI Powered Device to accept and use this power PSE Disabled over a twisted pair interface 7 PSE LPT Up Disabled PSE LPT Down Enabled PSE LPT This feature is used to re initialize a powered device PD If the
Download Pdf Manuals
Related Search
Related Contents
⑦ 底開き式コンテナ 取扱説明書 ⑥ ② ① ④ ⑤ Ione Conceição Pereira Pinto - uea Prothèse auto—adhésive pourries oreilles canines Manual de instrucciones Preamplificador de 8 elementos Untitled Copyright © All rights reserved.
Failed to retrieve file