Trane 120R9V User's Manual

image

Contents

1. BAYVENT10OA Sidewall Vent Termination Kit sirisser detriansa rear a AE a e aa be dd sea ae Qd voc ea UR dea Ee Fed Reve ERR e Few e BAYVENT20OOB Manufactured Mobile Home nnne e aiir ea BAYMFGH100A Optional kit allows 200 ft max vent length from 5 000 12 000 feet above sea level See installer s guide Pub No 22 1682 05 0802 EN 5 e General Data TUY R9V PRODUCT SPECIFICATIONS MODEL TUYO60R9V3V TUYO80R9V3V TUY100R9V4V TUY120R9V5V RATINGS 151 Stage Input BTUH 39000 52000 65000 78000 1st Stage Capacity BTUH ICS 37000 49000 62000 74000 2nd Stage Input BTUH 60000 80000 100000 120000 2nd Stage Capacity BTUH ICS 56000 73000 93000 112000 AFUE ICS 93 0 92 5 93 0 92 5 Temp Rise Min Max F 35 65 35 65 35 65 40 70 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Dia Width In 10x8 10x8 10x10 10x10 No Used 1 1 1 1 Speeds No VARIABLE VARIABLE VARIABLE VARIABLE CFM vs in w g SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF TABLE SEE FAN PERF TABLE Motor HP 1 2 1 2 1 1 RPM VARIABLE VARIABLE VARIABLE VARIABLE Volts Ph Hz 115 1 60 115 1 60 115 1 60 115 1 60 COMBUSTION FAN TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Drive No Speeds DIRECT VARIABLE DIRECT VARIABLE DIRECT VARIABLE DIRECT VARIABLE Motor HP RPM 1 15 5000 1 15
2. 5000 1 15 5000 1 25 5000 Volts Ph Hz 115 1 60 115 1 60 115 1 60 115 1 60 FL Amps 14 14 14 14 FILTER Furnished YES YES YES YES Type Recommended HIGH VELOCITY HIGH VELOCITY HIGH VELOCITY HIGH VELOCITY Filter No Size Thk 1X17X25X1 1X17X25X1 1 20X25X1 1 24X25X1 VENT Size In 2 ROUND 2 ROUND 3 ROUND 3 ROUND HEAT EXCHANGER Type Fired ALUMINIZED STEEL TYPE 1 ALUMINIZED STEEL TYPE 1 ALUMINIZED STEEL TYPE 1 ALUMINIZED STEEL TYPE 1 Unfired Gauge Fired 20 20 20 20 ORIFICES Main Nat Gas Qty Drill Size 3 45 4 45 5 45 6 45 L P Gas Qty Drill Size 3 56 4 56 5 56 6 56 GAS VALVE REDUNDANT TWO STAGE REDUNDANT TWO STAGE REDUNDANT TWO STAGE REDUNDANT TWO STAGE DIRECT IGNITION DEVICE Type HOT SURFACE IGNITER HOT SURFACE IGNITER HOT SURFACE IGNITER HOT SURFACE IGNITER BURNERS Type IN SHOT IN SHOT IN SHOT IN SHOT Number 3 4 5 6 POWER CONN V Ph Hz 115 1 60 115 1 60 115 1 60 115 1 60 Ampacity In Amps 84 84 114 114 Max Overcurrent Protection Amps 15 15 15 15 PIPE CONN SIZE IN 0 50 0 50 0 50 0 50 DUCT CONN SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING DIMENSIONS HXWXD HXWXD HXWXD HXWXD Crated In 41 3 4 X 19 1 2 X 30 1 2 41 3 4 X 19 1 2 X 30 1 2 41 3 4 X 23 X 30 1 2 41 3 4 X 26 1 2 X 30 1 2 Uncrated SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING WEIGHT Shipping Lbs Net Lbs 158 146 158 148 171 160 205 1
3. GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES BOX SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM THESE LEADS PROVIDE 115 V POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER MAX LOAD 1 0 AMPS EACH TO 115V 1 PH SET DIP SWITCHES WITH POWER OFF PER INSTALLATION INSTRUCTIONS 60 HZ POWER TO SET AIRFLOW AND INDOOR FAN OFF DELAYS SUPPLY PER CONTINOUS FAN AIRFLOW CAN BE INCREASED BY ADDING THIS JUMPER LOCAL CODES HUM SEE INTER COMPONENT WIRING NOTE 5 EAC SEE FURNACE NOTE 5 DIP SWITCH A ON 8 FACTORY RATED FURNACE orr 0000 0000 447 inSTALLEO T HEAT OSTAT TERMINALS JUMPER 2 STAGE HE ING THERMOSTAT WITH G we Wi B O Y YLOBK R FAN SWITCH TERMINALS 22222222 SEE B NOTE 7 From Dwg 21B341126 Rev 0 12 Pub No 22 1682 05 0802 EN e TRANE FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING COOLING OUTDOOR SECTION WITHOUT TRANSFORMER NOTES BE SURE POWER AGREES WITH EQUIPMENT NAMEPLATE S LOW VOLTAGE 24 V WIRING TO BE NO 18 A W G MIN GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM THESE LEADS PROVIDE 115 V POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER MAX LOAD 1 0 AMPS EACH THIS WIRE 15 ONLY FOR THERMOSTATS REQUIRING CONNECTION TO TRANSFORMER COMMON TERMI
4. Upflow Horizontal Two stage Condensing Gas Fired Furnace XV 90 TUY060 080 100 120R9V Variable Speed Blower Variable Speed Inducer PUB NO 22 1682 05 0802 EN e 2002 American Standard Inc All Rights Reserved General Features NATURAL GAS MODELS Central heating furnace designs are certified by the International Approval Services IAS for both natural and L P gas Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards SAFE OPERATION The Integrated System Control has solid state devices which continuously monitor for presence of flame when the system is in the heating mode of operation Dual solenoid combination gas valve and regulator provide extra safety QUICK HEATING Durable cycle tested heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure Low energy power vent blower to increase efficiency and provide a positive discharge of gas fumes to the outside BURNERS Multi port In shot burners will give years of quiet and efficient service All models can be converted to L P gas without changing burners INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors blowers gas valve flame control and includes self diagnostics for ease of service Also contains connecti
5. 1VINOZ MuOH 0 3014 dol LNOU4 0 uviu 53015 NOILYDI IddY 539089 403 318Vl HL NJI LNGA JHL Ol 813438 SFONLIL IW 1 398333 0 1Y S13004 3WOS NO UO 2 1 2 OL Q31INI1 38 AWW 3dld INJA 30 9313WVIQ NO 9NIQN3d3Q0 1 NO V 6 NYHL 0 nAn 38 AVW 831131 38AVW H3113 X1 33Ud S310N 1 43 5 EZ 91 61 2 ell ve SGAGYOZ TAN sVAGYOOI AN ell Ll 3 A64080A07 3 A680090A07 281 S310N 335 1300W IV Nivud J31VSN3QNOO 0 93 VIG 8 1 ell ve CALVNYFLIV AlddNS SVO OM TWIG a AINO 3 NIVHO 31VSN3QNOD O A VIQ 8 HIV NYNLIY q WOLLOS 1 71 NIVYd 31VSN3QNOO LNOYDONY 1015 B L X 8 L I e 1 82 gen wP E 2 4 8 L 1 1 8 8 6 0 211 22 1 0 91 1 2 VIQG 91 61 415 NOII1VOlI lddV TVLNOZIYOH 31VNu311V AlddN 1v21812313 O VIO 8 1 S3HONI NI 38V SNOISN3IIG T1V AlddNS SV9 e l S 1293NNOO 3113 48313AVIQ ONIAWUG ANITLNO A A6Y ANL uiv 34151 0 8313AVIQ udu 15 Pub No 22 1682 05 0802 EN CERTIFIED e TRANE Trane A business of American Standard Companies Since Trane has a policy of continuous product improvemen
6. ON OFF 60 1 ON 100 1 EAC N OFF ON 1 OFF OFF 180 FACTORY SETTING 1 1 1 TIS 3 RPM SOA 13 VOC 2 3 HI EN GND 5 1 7 8 OT PRESS ACTUATED SWITCH oo DOOR SWITCH MANUAL RESET THERMAL SWITCH FUSE O TERMINAL TERMINAL BOARD OLOR OF WIRE BLACK WIRE WITH BK BL BLUE MARKER a OF MARKER BK BLACK OR ORANGE YL YELLOW BL BLUE RDRED GR GREEN BR BROWN WH WHITE PR PURPLE GV GAS VALVE CF CAPACITOR GND GROUND Lo LINE LVTB LOW VOLTAGE TERMINAL BOARD MTR MOTOR N NEUTRAL TCO HIGH TEMPERATURE LIMIT SWITCH TNS TRANSFORMER HI FIRE SECOND STAGE LO LOW FIRE FIRST STAGE B C COMMON LPS PS PRES SW INPUT FIRST STAGE HPS PS2 PRES SW INPUT SECOND STAGE HLI HIGH LIMIT INPUT HLO HIGH LIMIT OUTPUT FP FLAME SENSOR PROBE GAS VALVE HIGH SECOND STAGE MVL GAS VALVE LOW FIRST STAGE FUSE BA TR 24V AC TRANG COMMON SIDE 24 AC TRANS HOT SIDE oN ICM INTEGRAL CONTROL AND MOTOR LC LINE CHOKE 4 THERMALLY PROTECTED INTERNALLY LOEN HPS PS2 1 ps d 1 agnostic 2 RD 2 Nee WH 4 IND LO 905 n NOTE 3 BK 3 4 me BK S 3 es SNL BL IGNITOR NOTE BK 2
7. Stage Capacity 2nd Stage Capacity EXTERNAL STATIC PRESSURE 74 000 112 000 1090 62 165 1210 56 220 1340 50 295 1430 47 390 1660 63 485 1870 56 675 2060 51 880 2200 48 1030 1120 60 225 1200 56 280 1360 50 350 1570 43 490 1690 62 590 1870 56 745 1990 53 890 2090 50 965 1080 63 270 1200 56 330 1370 49 425 1580 43 565 1680 62 640 1810 58 770 1850 57 810 1940 54 895 1070 63 310 1180 57 395 1380 49 495 1570 43 625 1640 64 675 1680 62 715 1710 61 750 1790 58 830 EXTERNAL STATIC PRESSURE 1230 445 1410 560 1380 575 1420 565 1480 600 1490 620 1530 615 1530 655 1620 730 1010 67 380 1160 58 455 1330 51 535 1390 49 565 1460 1530 68 665 1640 64 750 NOTES Factory setting 10 Pub No 22 1682 05 0802 EN e TRANE Electrical Data SCHEMATIC DIAGRAMS FOR GAS FURNACES LEGEND TUY060 080 100 120R9V V FACTORY WIRING 115 VOLT 60 HZ 1PH POWER SUPPLY J PER LOCAL CODES LINE V A Y E ME SPIEL WIRING os EARTH GROUND TO ICM N a VCHASSIS GROUND FAN CONTROL JUNCTION WIRE NUT OR CONNECTOR CAPACITOR SERRE TRANSFORMER ICM FAN no ion L4 CONNECTOR MTR JUMPER 5 TEMP ACTUATED SWITCH YL BK PA LINE HEAT OFF DELAY ISECONDS 1 WH 7 cian SWI SW DELAY
8. nennen tenen sior BAYCLE2100C Coil Enclosure 24 1 2 Wide Cabinets BAYCLE2400C led qm E BAYFLTR200 Filter Kit Horizontal Conversion TUYO60 080 R ccccescceeeseeeeeneeeeseeeeseeeeescneeeceeeecseaeeesesueeseneeeseeeeesceeeseseeessaeess BAYFLTR203 Filter Kit Horizontal Conversion TUY 100 R ccccsccceessecesseeeeeeaeeeceaaeeeeaeeeceaeeecsaeeessaneesseaeesscaeeeseeaeeseaeessceeseneeeessnsess BAYFLTR204 Filter Kit Horizontal Conversion TUY 120 R sssssssssssssseseeeeennen nennen nennen nennen BAYFLTR205 Filter Accessory Kit Upflow 14 5 BAYFLTR317 Filter Accessory Kit Upflow 21 Furnaces ssssseseeeeeeeennn eene nnne nenne herren nennen nennen nennen nnne BAYFLTR321 Filter Accessory Kit Upflow 24 5 Furnaces ntes enn nennen nter nnne nen BAYFLTR324 High Altitude Switch TUYOGOR tenen rese tnter sitne nnn enne BAYHALT245 High Altitude Switch TUY080 100R BAYHALT246O High Altitude Switch TUV 120R E a BAYHALT247O Sere rni
9. 6 in the ON position 1 At continuous fan setting Heating or Cooling airflows are approximately 50 of selected cooling value 2 LOW airflow 350 cfm ton is COMFORT amp HUMID CLIMATE setting NORMAL airflow 400 cfm ton is typical setting HIGH airflow 450 cfm ton is DRY CLIMATE setting TUY100R9V4V FURNACE HEATING AIRFLOW CFM AND POWER WATTS VS EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity 62 000 2nd Stage Capacity 93 000 AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE sermo FL os os D o7 09 CFM 920 920 920 920 920 ON ba RISE 60 60 60 60 60 S 130 180 220 280 320 1020 1020 1020 1010 1000 MEDIUM LOW 54 54 54 55 56 165 220 260 310 365 1160 1160 1160 1160 1150 STAGE NORMAL JEMEN 48 48 48 48 220 260 325 390 1350 1380 1400 1400 HIGH TEMP A 4 40 40 40 320 400 470 540 585 1290 1290 1330 1340 1320 67 67 65 64 65 275 355 430 490 545 1410 1460 1460 1460 1370 MEDIUM LOW OFF TEMP RISE 61 59 59 59 63 D WATTS 3561 455 520 590 590 re CFM 1640 1640 1640 1600 1410 NORMAL OFF TEMP RISE 53 53 53 54 61 WATTS 530 590 660 695 620 CFM 1970 1920 1780 1660 1520 HIGH OFF OFF TEMPRISE 45 48 52 57 WATTS 895 820 760 695 NOTES Factory setting Pub No 22 1682 05 0802 EN 9 e TRANE Performance Data TUY120R9V5V FURNACE COOLING AIRFLOW CFM AND POWER WATTS VS EXTERNAL STATIC PRESSURE WITH FILTER OUT
10. 93 Central Furnace heating designs are certified by AGA and CSA For U S applications above input ratings BTUH are up to 2 000 feet derate 4 per 1 000 feet for elevations above 2 000 feet above sea level For Canadian applicaitons above input ratings BTUH are up to 4 500 feet derate 4 per 1 000 feet for elevations above 4 500 feet above sea level Based on U S government standard tests The above wiring specifications are in accordance with National Electrical Code however installations must comply with local codes Pub No 22 1682 05 0802 EN e TRANE Performance Data UYO60R9V3V FURNACE COOLING AIRFLOW CFM AND POWER WATTS VS EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR NARON DIP SWITCH SETTING EXTERNAL STATIC PRESSURE TONS SETTING SW 1 SW 2 LOW 350 CFM TON NORMAL 400 CFM TON SW 3 SW 4 Pex oa os or oa ee 575 575 575 550 ATTS 65 90 125 155 m 640 640 640 630 70 110 140 175 700 700 700 700 Ts 85 125 160 200 700 700 700 700 Ts 100 130 170 210 800 800 800 800 Ts 115 155 200 250 900 900 900 900 875 875 875 875 5 130 180 230 270 1000 1000 1000 1000 900 TTS 175 235 285 335 310 CFM 1125 1125 1125 1100 925 ATTS 235 295 345 370 318 CFM 1050 1050 1050 1050 920 ATTS 195 260 305 350 315 CFM 1200 1200 1200 1100 940 WATTS 275 330 385 385 330 HIGH CFM 1325 1325 1300 1175 1000 450 CFM TON WATTS 360 425 460 425 365 NOTES First letter may be A or T 1
11. AGE AIR CONDITIONING OUTDOOR SECTION WITHOUT TRANSFORMER From Dwg 21B341125 Rev 1 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING OUTDOOR SECTION WITHOUT TRANSFORMER BE SURE POWER AGREES WITH EQUIPMENT NAMEPLATE S LOW VOLTAGE 24 V WIRING TO BE NO 18 A W G MIN GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM THESE LEADS PROVIDE 115 V POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER MAX LOAD 1 0 AMPS EACH THIS WIRE 15 ONLY FOR THERMOSTATS REQUIRING CONNECTION TO TRANSFORMER COMMON TERMINAL THE Y TERMINAL FROM THE THERMOSTAT MUST BE WIRED TO THE Y TERMINAL OF THE FURNACE CONTROL FOR PROPER BLOWER OPERATION DURING COOLING GROUND SCREW IX LURNACE JUNCTION BOX SET DIP SWITCHES WITH POWER OFF PER TO SET AIRFLOW AND INDOOR FAN OFF DELAYS OPTIONAL HUMIDISTAT 15 TO BE CONNECTED BETWEEN AND BK FACTORY INSTALLED JUMPER R TO BK ON THE CIRCUIT BOARD MUST BE CUT IF OPTIONAL HUMIDISTAT IS USED THE JUMPER MUST ALSO BE CUT WHEN APPLYING AN AIRFLOW COMMAND SIGNAL TO THE BK INPUT SUCH AS WITH THE VARIABLE SPEED SINGLE ZONE AND MULTI ZONE SYSTEM CONTROLLERS ON SINGLE SPEED COOLING ONLY NON HEAT PUMP SYSTEMS JUMPER Y TO 0 FOR PROPER OPERATION OF THE DELAY PROFILES AND THE HUMIDISTAT FOR TWO COMPRESSOR OR TWO SPEED SYSTEMS JUMPER YLO TO 0 INSTALLATION INSTRUCTIONS TO 115 V 1 PH 60 HZ POWE
12. At continuous fan setting Heating or Cooling airflows are approximately 50 of selected cooling value 2 LOW airflow 350 cfm ton is COMFORT amp HUMID CLIMATE setting NORMAL airflow 400 cfm ton is typical setting HIGH airflow 450 cfm ton is DRY CLIMATE setting zn HIGH 450 CFM TON LOW 350 CFM TON NORMAL 400 CFM TON HIGH 450 CFM TON B LOW 400 CFM TON HIGH 450 CFM TON 850 CFM TON NORMAL UYO60R9V3V FURNACE HEATING AIRFLOW CFM AND POWER WATTS VS EXTERNAL STATIC PRESSURE WITH FILTER ist Stage Capacity 37 000 2nd Stage Capacity 56 000 AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE p 600 600 600 p s RISE 57 57 57 TTS 85 110 155 i 30 son 700 700 700 T MEDIUM LOW TMR RISE 49 49 49 EA TTS 90 130 175 STAGE soon 775 775 y m NORMAL b RISE 44 44 TTS 155 ie Ao 870 870 870 870 HIGH RISE 39 39 39 39 TTS 235 290 a 860 920 920 920 670 Ie RISE 61 57 57 57 79 TTS 140 200 245 300 245 1000 1000 1000 1000 700 MEDIUM LOW T RISE 53 53 53 53 75 HENT s TTS 190 255 305 340 255 STAGE Es 1125 1125 1125 1025 775 NORMAL RISE 47 47 47 51 68 TTS 250 315 370 355 285 1250 1250 1250 1100 1000 HIGH OFF OFF TEMP RISE 42 42 42 48 53 WATTS 340 405 445 390 355 NOTES First letter may be A or T Factory setting Pub No 22 1682 05 0802 EN 7 Performance Data TUYO80R9V3V FURNA
13. BE NO 18 A W G MIN SCREW GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES puc FURNACE SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM JUNCTION THESE LEADS PROVIDE 115 V POWER FOR CONNECTION OF ELECTRONIC BOX AIR CLEANER AND HUMIDIFIER MAX LOAD 1 0 AMPS EACH WHEN A SINGLE STAGE HEATING THERMOSTAT WITHOUT FAN SWITCH IS USED NO WIRING ON G TERMINAL IS USED TO 115 V 1 PH WI AND W2 MUST JUMPERED TOGETHER FOR PROPER OPERATION 60 HZ POWER SECOND STAGE HEAT WILL BEGIN IO MINUTES AFTER FIRST STAGE SUPPLY PER SET DIP SWITCHES WITH POWER OFF PER INSTALLATION INSTRUCTIONS LOCAL CODES TO SET AIRFLOW AND INDOOR FAN OFF DELAYS CONTINOUS FAN AIRFLOW CAN BE INCREASED BY ADDING THIS JUMPER HUM SEE NOTE 5 FURNACE INTER COMPONENT WIRING 1 EAC SEE 5 DIP SWITCH mnm 1 RATED FURNACE M 8 FACTORY OSrAT TERMINALS _ C0000000 FT INSTALLED es JUMPER SINGLE STAGE HEATING THERMOSTAT WITH FAN G W2 Wi B Y YLO Bk R SWITCH TERMINALS eoeleoeeoo o FIELD ADDED JUMPER 1 SEE NOTE 7 SEE NOTE 9 SEE NOTE 6 7 From Dwg 21B341127 Rev 0 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING THERMOSTAT GROUND NOTES Va FURNACE BE SURE POWER AGREES WITH EQUIPMENT NAMEPLATE S JUNCTION LOW VOLTAGE 24 V WIRING TO BE NO I8 A W G MIN
14. CE COOLING AIRFLOW CFM AND POWER WATTS VS EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE TONS AIRFLOW SETTING See Notes LOW 350 CFM TON NORMAL 400 CFM TON HIGH 450 CFM TON LOW 350 CFM TON DIP SWITCH SETTING 4 ESL ON ON FF a 0 1 CFM 750 750 750 720 WATTS 84 122 154 185 CFM 840 840 840 840 WATTS 109 146 181 226 CFM 940 940 940 940 WATTS 136 215 274 os T 177 CFM 850 850 870 890 WATTS 113 150 200 250 EXTERNAL STATIC PRESSURE 710 221 820 264 940 318 890 295 om on or om wars iso zo s so escrow OF on on om wars e ms s se so N o on was s z zo so se N o o om wars mo so so eo s emmo om om wars so so so so NOTES Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the ON position 1 At continuous fan setting Heating or Cooling airflows are approximately 50 of selected cooling value 2 LOW airflow 350 cfm ton is COMFORT amp HUMID CLIMATE setting NORMAL airflow 400 cfm ton is typical setting HIGH airflow 450 cfm ton is DRY CLIMATE setting TUYO80R9V3V FURNACE HEATING AIRFLOW CFM AND POWER WATTS VS EXTERNAL STATIC PRESSURE WITH FILTER DIP SWITCH SETTING AIRFLOW SETTING ids NOTES Factory set
15. DOOR UNIT SIZE TONS AIRFLOW SETTING See Notes LOW 350 CFM TON 3 NORMAL 400 CFM TON HIGH 450 CFM TON W OFF Ea LOW 350 CFM TON NORMAL 400 CFM TON HIGH 450 CFM TON LOW 350 CFWTON NORMAL HIGH 450 CFM TON 5 0 5 EJEA EE EAE EAE EJEA EES FF FF ON FF FF ON FF FF ON OFF OFF OFF OFF OFF FF EXE DIP SWITCH SETTING SW 4 WATTS 220 270 325 400 ATTS 305 390 465 510 425 520 600 645 OFF ON OFF OFF 1800 1780 1780 1700 570 630 705 695 2050 2010 1860 1710 845 875 805 735 2160 2040 1920 1780 995 805 OFF dd 935 875 NOTES Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the ON position 1 At continuous fan setting Heating or Cooling airflows are approximately 50 of selected cooling value 2 LOW airflow 350 cfm ton is COMFORT amp HUMID CLIMATE setting NORMAL airflow 400 cfm ton is typical setting HIGH airflow 450 cfm ton is DRY CLIMATE setting TUY120R9V5V FURNACE HEATING AIRFLOW CFM AND POWER WATTS VS EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING por pes Lo CFM LOW HEATING 1ST STAGE HEATING 2ND STAGE TEMP RISE WATTS CFM TEMP RISE WATTS CFM TEMP RISE WATTS CFM TEMP RISE WATTS i i ON TEMP RISE WATTS CFM OFF ON TEMP RISE WATTS CFM ON OFF TEMP RISE WATTS CFM OFF OFF TEMP RISE WATTS 1st
16. Fit High Efficiency 14 1 2 Wide Gas Furnace TFM145A9FRO Electronic Air Filter Perfect Fit High Efficiency 17 1 2 Wide Gas Furnace TFM175A9FRO Electronic Air Filter Perfect Fit High Efficiency 21 Wide Gas Furnace TFM210A9FRO Electronic Air Filter Perfect Fit High Efficiency 24 1 2 Wide Gas Furnace TFM245A9FRO Electronic Air Filter Perfect Fit Standard Efficiency 14 1 2 Wide Gas Furnace TFP145A9FRO Electronic Air Filter Perfect Fit Standard Efficiency 17 1 2 Wide Gas Furnace TFP175A9FRO Electronic Air Filter Perfect Fit Standard Efficiency 21 Wide Gas Furnace TFP210A9FRO Electronic Air Filter Perfect Fit Standard Efficiency 24 1 2 Wide Gas Furnace TFP245A9FRO Coil Enclosure 14 1 2 Wide 5 BAYCLE1400C Coil Enclosure 17 1 2 Wide Cabinets ssssssessssseeseeeeeeeennnee nnne tnnen nennt nenne trennen nnne nes BAYCLE1700C Coil Enclosure 21 Wide Cabinets
17. LIGHT CFM FLASHES ONCE PER 100 CFM COMMAND ue 7 FOR HEAT PUMP SYSTEMS Y AND 0 MUST BE CONNECTED TO THE LOW VOLTAGE TERMINAL BOARD 8 FOR TWO SPEED SYSTEMS USE YLO FOR LOW SPEED AND Y FOR HIGH SPEED CONNECTION TO THE LOW VOLTAGE TERMINAL BOARD 9 0PTIONAL HUMIDISTAT IS TO BE CONNECTED BETWEEN R AND BK FACTORY INSTALLED JUMPER R TO BK ON THE CIRCUIT BOARD MUST BE CUT IF OPTIONAL HUMIDISTAT IS USED THE JUMPER MUST ALSO BE CUT WHEN APPLYING AN AIRFLOW COMMAND SIGNAL TO THE BK INPUT SUCH AS WITH THE VARIABLE SPEED SINGLE ZONE AND MULTI ZONE SYSTEM CONTROLLERS ON SINGLE SPEED COOL ING ONLY NON HEAT PUMP SYSTEMS JUMPER Y 10 0 FOR PROPER OPERATION OF THE DELAY PROFILES AND THE HUMIDISTAT FOR TWO COMPRESSOR OR TWO SPEED SYSTEMS JUMPER YLO TO D TO THERMOSTAT 10 SEE CHART LOCATED IN THE FURNACE INFORMATION ENVELOPE SEE NOTES 2 4 5 6 7 8 9 FOR DIP SWITCH SETTINGS TO SET AIRFLOW AND COOLING TO OFF DELAYS 11 POWER MUST BE OFF WHEN DIP SWITCHES ARE SET ICM FAN MOTOR 12 USED FOR UYIOORSV4 AND UYI20R9V5 MODELS ONLY ON OFF JUMPER TEST YELL Ow Bk R JUMPER GREEN 795 Mec mole d Gw W B 0 Y YLO BK R ES Y 5 55 From Dwg 21D341111 Pub No 22 1682 05 0802 EN 11 NOTES BE SURE POWER AGREES WITH EQUIPMENT NAMEPLATE S GROUND LOW VOLTAGE 24 V WIRING TO
18. NAL THE Y TERMINAL FROM THE THERMOSTAT MUST BE WIRED TO THE Y TERMINAL OF THE FURNACE CONTROL FOR PROPER BLOWER OPERATION DURING COOLING GROUND SCREW ge FURNACE JUNCTION BOX SET DIP SWITCHES WITH POWER OFF PER TO SET AIRFLOW AND OPTIONAL HUMIDISTAT INSTALLATION INDOOR FAN OFF DELAYS INSTRUCTIONS LH TO 115 V PH 60 HZ POWER SUPPLY PER LOCAL CODES LN WH SYSTEMS INSTALLED JUMPER R TO BK ON THE CIRCUIT BOARD MUST BE CUT HUMIDISTAT COMMAND SIGNAL TO THE BK AND MULTI 15 TO BE CONNECTED BETWEEN AND BK FACTORY IF OPTIONAL THE JUMPER MUST ALSO BE CUT WHEN APPLYING AN AIRFLOW INPUT SUCH AS WITH THE VARIABLE SPEED SINGLE ZONE ZONE SYSTEM CONTROLLERS ON SINGLE SPEED COOLING ONLY NON HEAT PUMP JUMPER Y TO 0 FOR PROPER OPERATION OF THE DELAY PROFILES AND THE 15 USED HUMIDISTAT FOR TWO COMPRESSOR OR TWO SPEED SYSTEMS JUMPER YLO TO 0 INTER COMPONENT WIRING 24 EAC SEE ine 5 DIP SWITCH ACTOR IRING Y FURNACE LLL ua TN E R 0000 orr 1 INTEGRATED 0000 FURNACE CO THERMOSTAT NTROL TERMINALS G wm B j eh FACT 4 INST JUMP SINGLE STAGE HEATING COOLING THERMOSTAT WITH FAN SWITCH TERMINALS D 0000 ORY YLO BK Qe EIELO ADDED JUMPE SEE NOTE 6 LOW VOLT
19. R SUPPLY PER LOCAL CODES INTER COMPONENT WIRING EAC SEE NOTE 5 DIP SWITCH FURNACE 8 0000 2 STAGE HEATING SINGLE STAGE COOLING THERMOSTAT WITH FAN SWITCH TERMINALS NTEGRATED URNACE CO HERMOSTAT 1 0000 NTROL or TERMINALS eamm c 4 Tory NSTALLEO YLO BK ER QQ B 0 Y o LOW VOLTAGE AIR CONDITIONING OUTDOOR SECTION WITHOUT TRANSFORMER From Dwg 21B341124 Rev 1 Pub No 22 1682 05 0802 EN 13 Field Wiring FIELD WIRING DIAGRAM FOR 2 STAGE HEATING TWO STAGE COOLING OUTDOOR SECTION WITHOUT TRANSFORMER GROUND SCREW INTER COMPONENT WIRING TO 115 V 1 PH 60 HZ POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 WH EAC SEE NOTE 5 BK D DIP SWITCH POWER SUPPLY Cp qp 1 E e 0000 0000 TROL TERMINALS 2 STAGE HEATING TWO FACTORY STAGE COOLING THERMOSTAT WITH g G W2 Wi B O Y YLO BK R JUMPER FAN SWITCH TERMINALS oooooooo0o oO 00006230 Y POWER SUPPLY i i UNIT 2 ig B SEE NOTE 7 x Y LOW VOLTAGE AIR CONDITIONING OUTDOOR SECTION WITHOUT TRANSFORMER NOTES BE SU
20. RE POWER AGREES WITH EQUIPMENT NAMEPLATE S LOW VOL TAGEI24 V WIRING TO BE NO 18 A W G MIN GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM THESE LEADS PROVIDE 15 V POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER MAX LOAD 1 0 AMPS EACH THIS WIRE IS ONLY FOR THERMOSTATS REQUIRING CONNECTION TO TRANSFORMER COMMON TERMINAL THE Y2 TERMINAL FROM THE THERMOSTAT MUST BE WIRED TO THE Y TERMINAL OF THE FURNACE CONTROL FOR PROPER BLOWER OPERATION DURING COOLING SET DIP SWITCHES WITH POWER OFF PER INSTALLATION INSTRUCTIONS TO SET AIRFLOW AND INDOOR FAN OFF DELAYS OPTIONAL HUMIDISTAT IS TO BE CONNECTED BETWEEN R AND BK FACTORY INSTALLED JUMPER R TO BK ON THE CIRCUIT BOARD MUST BE CUT IF OPTIONAL HUMIDISTAT IS USED THE JUMPER MUST ALSO BE CUT WHEN APPLYING AN AIRFLOW COMMAND SIGNAL TO THE BK INPUT SUCH AS WITH THE VARIABLE SPEED SINGLE ZONE AND MULTI ZONE SYSTEM CONTROLLERS ON SINGLE SPEED COOL ING ONLY NON HEAT PUMP SYSTEMS JUMPER Y TO O FOR PROPER OPERATION OF THE DELAY PROFILES AND THE HUMIDISTAT FOR TWO COMPRESSOR OR TWO SPEED SYSTEMS JUMPER YLO TO O From Dwg 21B341128 Rev 0 14 Pub No 22 1682 05 0802 EN e TRANE Imensions D 9119 1 7 91 6 1 q 3113 401 1NOHUj uvis 1331 1 914 53015 138012 anid dol 1 043 1331 LHOIY 53415 3 A021V 1431 NO 39UvHOSIQ 3013
21. l switch Pub No 22 1682 05 0802 EN Pub No 22 1682 05 0802 EN e TRANE Contents Feature Summary Features and Benefits Standard Equipment Optional Equipment General Data TUYO60R9V3V TUYO80R9V3V TUY100R9V4V TUY120R9V5V Performance Data Electrical Data Field Wiring Dimensions 11 12 15 e Features and Benefits XV 90 STANDARD EQUIPMENT Variable speed indoor blower Silicon Nitride Igniter with adaptive heat up Variable speed induced draft blower Direct Non Direct vent option Fused 24 volt control circuit Manual reset burner safety switches Power supply 115 1 60 Convertible to horizontal on left side 2 stage gas valve PVC venting 1 or 2 pipe option Accessory hook up capability Integrated solid state control with self diagnostics Attractive color accents Heavy gauge aluminized steel heat exchanger Multi port In shot burners e Hinged blower door Perfect fit door latches Insulated blower door Gasketed blower door Internal filter rack Standard filter sizes Two tone color Complete front service access Left right gas connection Adjustable fan off times Cleanable high velocity filters Optional L P conversion kit Selectable cooling fan off delay eliminates need for BAY24X045 time delay kit Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner Residentia
22. l use 5 Year limited parts warranty Pub No 22 1682 05 0802 EN e TRANE Features and Benefits OPTIONAL EQUIPMENT Thermostat Mechanical 2 Stage Heating 1 Stage Cooling TAYSTAT241 Thermostat Heating Cooling Single Stage Mounts Horizontally AY28X092 Thermostat Heating Cooling Single Stage Mounts Vertically BAYSTAT305 Thermostat Electronic Programmable 2 Stage Heating 2 Stage Cooling seen 2 Thermostat Electronic Programmable 1 Stage Heating 1 Stage Cooling see Propane Conversion Kit BAYLPKT210A Electronic Air Filter Perfect Fit Super Efficiency 14 1 2 Wide Gas Furnace TFE145A9FRO Electronic Air Filter Perfect Fit Super Efficiency 17 1 2 Wide Gas Furnace TFE175A9FRO Electronic Air Filter Perfect Fit Super Efficiency 21 Wide Gas Furnace TFE210A9FRO Electronic Air Filter Perfect Fit Super Efficiency 24 1 2 Wide Gas Furnace TFE245A9FRO Electronic Air Filter Perfect
23. on points for E A C humidifier CONDENSATE DRAIN Built in trap which can drain from either side when the furnace is installed upflow AIR DELIVERY The variable speed direct drive blower motor has sufficient airflow for most heating and cooling requirements will switch from heating to cooling speeds on demand from room thermostat The blower door safety switch will prevent or terminate furnace operation when the blower door is removed SECONDARY HEAT EXCHANGER The XV 90 has a special type 29 4C stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost outside STYLING Heavy gauge steel and wrap around cabinet construction is used in the cabinet with baked on enamel finish for strength and beauty The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass Built in bottom pan and alternate bottom left or right side return air connection in vertical position FEATURES AND GENERAL OPERATION The XV 90 High Efficiency Gas Furnaces employ a Hot Surface Ignition system which eliminates the waste of a constant burning pilot The integrated system control lights the main burners upon a demand for heat from the room thermostat Complete front service access a Low energy power venter b Vent proving differentia
24. t it reserves the right to change design and www trane com specifications without notice
25. ting CFM TEMP RISE WATTS CFM TEMP RISE WATTS CFM TEMP RISE WATTS CFM TEMP RISE WATTS CFM TEMP RISE WATTS CFM TEMP RISE WATTS CFM TEMP RISE WATTS CFM TEMP RISE WATTS HEATING 1ST STAGE HEATING 2ND STAGE 1st Stage Capacity 49 000 2nd Stage Capacity 73 000 EXTERNAL STATIC PRESSURE 800 800 800 800 56 220 920 105 860 140 880 180 890 115 960 165 990 215 1000 265 1020 150 1080 41 195 1100 62 205 1210 57 265 1360 50 365 1360 50 355 200 1110 40 255 1100 62 260 1240 55 340 1390 49 445 1390 49 450 230 1120 40 315 1120 61 320 1260 54 410 1400 49 500 1400 49 520 310 1120 40 365 1120 61 370 1260 54 470 1360 50 535 1350 51 535 w T9 e o7 oo 800 56 265 1080 41 390 1090 63 400 1130 1210 57 475 1180 58 465 Pub No 22 1682 05 0802 EN e TRANE Performance Data TUY100R9V4V FURNACE COOLING AIRFLOW CFM AND POWER WATTS VS EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE cane opm 2 EU E Pein 350 vans 225 280 365 425 485 NORMAL CFM 1640 1640 1640 1590 1420 NUM va HIGH 1840 1840 1770 1630 1470 450 CFM TON wane 700 780 795 725 655 NOTES Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and
26. y exch INDUCER HS HOUSING LIMIT SW BIA BIG 3H won BC ine u HPS PS2 RD 3 reo BR RD 2 1 o 0R 1 RD 4 A LPS PSI 69 4 127591 YL I RD 4 MANUAL RESET FLAME ROLLOUT SWITCH LJ on UY R ENSOR 4 LAME HLO H YL S YL 2 GAS VALVE NOTES 1 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE MV coy BL I REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST I05 C MVL 6 RD I 2 THERMOSTAT HEAT ANTICIPATOR SETTING FIRST STAGE 38 AMPS SECOND STAGE 3 AMPS IF SETTING IS NOT FIXED ON THERMOSTAT IMPORTANT INTEGRATED FURNACE CONTROL FOR SINGLE STAGE HEATING THERMOSTAT SET AT 51 AMPS REPLACEMENT MUST BE AUTHORIZED THESE LEADS PROVIDE 120 POWER FOR CONNECTION OF ELECTRONIC AIR 5 0 PART ONLY CLEANER AND HUMIDIFIER MAX LOAD 1 0 AMPS EACH yt m 4 JUMPER WI AND W2 FOR SINGLE STAGE HEATING THERMOSTAT 7 SECOND STAGE WILL BE ENERGIZED 10 MINUTES AFTER A CALL FOR HEAT DIP SWITCH 5 FOR PROPER OPERATION OF COOL ING FAN SPEED Y TERMINAL MUST BE n SEE NOTE 10 AND II 1 BL MVH 1 BR I 1 1 CONNECTED TO ROOM THERMOSTAT 6 GREEN