Home

Soehnle Postal Equipment 3020 User's Manual

image

Contents

1. gt 0 resolution Switch to the x10 display by pressing the Print key and then the Zeroing key and hold them both down simultaneously Approvable scale Ifthe scale is approvable the ten times resolution appears and switches off after 5 seconds Non approved scale Ifthe scale is calibrated as non approved the ten times resolution appears constantly in the display Press the key once to activate the ten times resolution function Press the key again to deactivate the ten times resolution function B 26 10 Organisation data identifiers RG RG Organisation data help to assign identifiers to document weighing operations e g article number supplier machine operator They are available in all application programs The Digital Indicator 3020 has 4 organisation data memories Each memory has one freely definable description e g Article no up to 12 characters a freely definable content e g 1234 up to 28 characters The description is entered in Setting mode the content is entered during a weighing operation Type the description and content alphanumerically into the numerical keypad The ORG key is for calling the organisation data memory Description input First enter the descriptions max 12 characters for the required organisation data memory in Setting mode Call the Setting mode Press the Print key and the F key simultaneously Setting mode appears in the display The arrow points to
2. Program Settings Scroll through to Terminal mode by pressing the Tare key and then press the Print key to confirm Scroll through to Organisation data mode by pressing the Tare key and then press the Print key to confirm Select the required ORB data block A to D by pressing the F or Tare key and press the Print key to confirm The input box is displayed for you to enter the description Type in the description using the alphanumeric keypad and press the Print key to accept If necessary select the next ORB data block A to D by pressing the F or Tare key and press the Print key to confirm Repeat the procedure until you have entered all the required ORG data blocks Exit Setting mode with the ORG key The weight value is displayed Caution The organisation data memory is only activated when a description is entered Only activated organisation data memories can be called up by pressing the ORG key Content input In Weighing mode press the ORG key to enter the contents for the organisation data memory Type the content data alphanumerically into the numerical keypad max 28 characters Press the ORG key repeatedly to scroll through the assigned ORG data memories Confirm data input by pressing the Print key The description and content are then added to the weighing result as identification The content of the organisation data memory is retained until it is overwritten or cleared Printout When an ORG
3. data memory is activated and a print template is stored values are accepted when you press the Print key and generates a print command Only the organisation data containing an input are printed out Show content Press the ORG key Press the ORG key repeatedly to scroll through the assigned ORG data memories Delete the content Press the ORG key repeatedly until the data memory to be deleted is displayed Then press the C key to delete the data memory content in decades 2 7 Switching between scales E Switching between several connected scales Up to two measuring points can be mounted in the Digital Indicator 3020 Toggle between the measuring points by pressing the INFO key followed by the INFO ORG key in succession The activated measuring points are switched one after the other The display shows the number of the activated measuring point on the right of the symbol bar Press the Info key to display the calibration and scale data of the activated measuring point RG 28 Unit Displaying the weighing result in a second unit The unit in the display pane is defined in Setting mode during calibration You can activate or deactivate the display of the second unit in the additional indicator To achieve this assign the Second unit function to the F key see Setting mode t Press the F key to switch the second unit on and off Define the second unit in Setting mode for each connected scale For information on the
4. first free or otherwise the last selected fixed tare value memory is displayed Press the ORG key and then the Print key The input box for the description of a new tare memory is displayed Enter the description in the alohanumeric keypad and confirm by pressing the Print key The arrow points to Tare value Press the Print key The input box for the tare value is displayed Enter the tare value and confirm by pressing the Print key Return to tare memory selection by pressing the Zeroing key f you want to assign other tare memories press the ORG key to select the next free memory location and repeat the procedure as described above To return to Weighing mode press the Zeroing key and then the ORG key 15 b c Changing or overwriting a fixed tare value memory Press the Print key and the F key simultaneously Setting mode appears in the display The arrow points to Program Settings Confirm by pressing the Print key The arrow points to General Confirm by pressing the Print key Scroll to Fixed tare value with the Tare key and accept by pressing the Print key The last selected fixed tare value memory is displayed Select the tare memory you wish to change by pressing the F key or the Tare key or enter the memory location number and confirm by pressing the Print key Press the Print key the input box to enter the description of the tare memory is displayed Change the description in the alpha
5. is cleared a 3 2 10 Print command keys The Info and F keys can execute voucher printout This is dependent on whether a print template was assigned to the key in question lj 32 11 Displaying the current totals During a totalising operation you can display the totals reached by pressing the Info key and then the F key utiue number Gross total Tare tatal Het tatal al 3 2 12 Display options with the Info key INFO When you press the Info key you have the following options ix Minle F Displays the current content of the total memory Tare key Displays the current tare weight 20 3 3 3 3 1 3 3 2 3 3 3 3 3 4 Counting Counting parts with the same weight The single part weight reference weight is calculated from a known small quantity of countable parts This then becomes the divisor to determine the piece count from the weight of an unknown quantity of countable parts Function key Function of F key reference weight calculation Counting display view Brutto 136 ij LO MI al 431 pcs The weight value appears in the additional indicator Taring Taring functions same as for 3 1 Weighing and taring Counting function Determining the reference weight Function key F Ref 10 Calculating the reference weight from a default reference quantity Place 10 countable parts on the scale then press the Print key Get reference The scale calculates the reference weigh
6. FOR MEASURABLE SUCCESS PROFESSIONAL 3020 Operating Manual www soehnle professional com ENGLISH H Contents MM cup Introductioti codec ist et case Page 3 AMEDEO Basic Functions Page 8 DU sre deret e dep sccm nine Dc a fess caval Application Programs Page 13 Bol eiecit e diete eee rae Weighing and Taring Page 13 3 2 pre A Vx dien mee a qx eae s Totalising and Batching Page 18 BO cae d dos cod EUR abe op adn prec oe te n Counting mere oxen en s Page 21 Lr ae cr CHECKING sense Page 24 d Lusso ebbe iuo be area Further Information Page 25 Thank you for choosing this Soehnle Professional product All the features of this product were designed to the state of the art and are optimised for simple and straightforward use If you have any queries or experience any problems with your appliance not addressed in the operating manual please contact your Soehnle Professional service partner or visit us on the web at www soehnle professional com 1 1 Notes on the Operating Manual This operating manual is a short version of the Program Terminal 3020 and is intended to help you through your first steps with the scale and entry level operations This detailed manual is supplied on the CD so that you can obtain maximum performance from your new appliance It contains complete information on the application programs It also describ
7. Setting mode see the detailed CD manual 11 12 2 9 Alphanumeric input Use the combined numerical alphanumeric keypad to type in numerical and alphanumeric inputs similar to a mobile phone keypad Types of input box Display boxes with no write option Display type in boxes with numerical input option Display type in boxes with alphanumeric input option Activating input boxes Situation dependent by means of function key or direct numerical input The Input view appears in the display Existing values are displayed The description of the input box is displayed in the symbol bar A unit character is displayed if the input refers to a dimension Input procedure 1 Numerical boxes You can type in digits O to 9 using the numerical keypad Input is right flush A cursor flashes under the last digit entered The C key clears the digit marked by the cursor the Zero key terminates the input without accepting the new input value existing values are retained The Print key accepts the input value and returns to the application program In Setting mode Display Decimal Separator you can define whether to have a dot comma or blank as default decimal separator Only the default number of characters can be typed into an input box Any other inputs are neither displayed nor accepted 2 Alphanumeric boxes You can type in digits O to 9 using the numerical keypad Input is left flush The numeric keys have multiple pro
8. cept the first reference weight fixed value is displayed Press the F or Tare key to select the reference weight memory to be changed or type in the memory location number or article number depending on the presetting in Setting mode and confirm by pressing the Print key If the selected reference weight memory is in the display confirm by pressing the Print key The input box is displayed to enter the description of the reference weight memory Change the description in the alphanumeric keypad and confirm by pressing the Print key The arrow points to Article number Press the Print key to confirm the input box for the article number is displayed Change the article number in the numeric keypad and confirm by pressing the Print key The arrow points to Reference weight Press the Print key the input box for the reference weight is displayed Change the reference weight in the numeric keypad and confirm by pressing the Print key Return to reference weight memory selection by pressing the Zeroing key Clearing an existing fixed value The clear function only works in Setting mode Count Reference weight fixed value Scroll by pressing the Tare and F keys Clear the displayed fixed value by pressing the C key The gap in the consecutive number scheme is closed The following reference fixed value memories are given a number reduced accordingly Saving the new fixed value Entering a new reference value only works in Setting mo
9. characters Symbols in the display symbol bar Alibi memory capacity 100 Alibi memory capacity 80 Alibi memory capacity empty Keylock Second unit Multirange Multidivision 1 Multirange Multidivision 2 Multirange Multidivision 3 Resolution X10 Zero Hold function active Unit character Symbol for standstill After placing the weighing product on the scale the scale requires some time to settle Until the scale reaches standstill the unit character kg g is not displayed The unit character only appears when the scale reaches standstill and a stable value is obtained clip off 2 B21 B 22 Basic functions The basic functions are similar or identical for all application programs Power on off Power on After power on and during the run up phase the Soehnle Professional logo is displayed The measuring points are briefly listed as they are detected The scale is zeroed after the power on routine This may vary with non approved calibration On power on the last application program activated is displayed Zero range limits at power on Approvable Zero range at power on 20 of the weighing range The default value is 5 to 15 of the weighing range Non approved Zero range at power on 99 to 99 of the weighing range If the appliance is switched on outside the zero range the scale displays error message Error 50 51 Value outside zero range limit When t
10. d taring 2 Totalising and batching 3 Counting 4 Checking 3 0 1 Selecting an application program Switch the appliance on After the power on routine the appliance starts the last activated application program automatically F Call the Setting menu by pressing the Print and F keys simultaneously Pat The arrow points to Program Settings Press the Print key the arrow points to General Press the Print key the arrow points to Programs Press the Print key the arrow points to the program last selected Select the program you wish to activate by pressing the Tare key or F key Confirm the program by pressing the Print key 3 1 Weighing and taring Basic functions Weighing and measuring gross and net weights Warning This description applies to the options Autotare and Additive tare in the factory setting OFF When you activate these options in Setting mode it affects the procedures described 3 1 2 Display view Basic weighing view Brutto kg a 3 1 3 Weighing without taring Place weighing product on the scale The weight is indicated with the message Gross a 3 1 4 Manual taring INFO ix Min e Measure and tare with a container of unknown weight Place the empty container on the scale Press the Tare key The tare value is saved The weight display is zeroed The weight is displayed with the message Net When the scale is clipped off the tare weight is displayed w
11. de Count Reference weight fixed value The memory location number is assigned by the appliance The first figure in brackets indicates the number of free memory locations the second figure shows the memory locations occupied by reference fixed values Press the ORG key The Description parameter is marked Call by pressing the Print key Type in the value using the numerical alphanumeric keypad Press the Print key to accept the input Press the Zeroing key to cancel without accepting the input You can edit other parameters in the same way Exiting the fixed value list Press the Zeroing and ORG keys in succession to quit the list b Calling the list of reference weights for counting Press the F key to start the count operation Then press the ORG key two times The indicator shows the last fixed value called Selecting from the list Scroll to the required memory location by pressing the F or Tare key Accept the required fixed value by pressing the Print key Call directly by typing in the article number or memory location number Type in the article number or memory location number into the numerical keypad Setting mode defines whether to call the article number or the memory location number type the article number as search term left flush type the memory location number as search term right flush Confirm the required fixed value by pressing the Print key 3 3 5 Counting with several weighing platforms If sev
12. een totalising and batching is defined in Setting mode This selection applies to all connected weighing platforms As an example we will only describe the totalising function here Total memory with several connected scales A central total memory is managed for all connected scales Total memory capacity There are a maximum of 999 weighing operations in the total memory The total memory must then be cleared B 324 Function key F The totalising batching function is executed by pressing the F key t fj 3 22 Display view e r poen Frag 3 3 3 g J e wy After each totalising operation the message Totalising executed appears for 1 5 s in the display 18 3 2 3 3 2 4 INFO Max Min e 3 2 5 3 2 6 3 2 7 Taring Taring functions same as for 3 1 Weighing and taring Operating the totalising functions Press the F key to transfer the weight on the weighing platform to the total memory t The item counter and the consecutive number are incremented by 1 Before requesting the next total the scale must be clipped off at least to the clip off factor defined in Setting mode A weight value of 0 or a total without clip off results in Error 55 Place weight on scale If the clip off factor 0 only a brief weight change is required Ending the totalising function The totalising operation is terminated by pressing the key combination INFO F and Print At the same time the totals are printed
13. eral scales are connected the reference weight can be determined and counted on each scale We advise you to determine the reference weight using the finest resolution on the scale Select a scale by pressing the Scale key After measuring the reference weight you can switch to a bulk scale with a higher load capacity in order to count large quantities precisely with the reference weight determined using the reference scale 3 3 6 Display options with the Info key INFO When you press the Info key you have the following options x Min e F key Displays the current reference weight Tare key Anzeige des aktuellen Taragewichtes p 34 B 3 4 1 B 3 4 2 B 3 4 3 B 3 4 4 Checking Checks whether the weighing product corresponds to a setpoint weight within a default tolerance band Example If you want to check whether several weighing products This function can also be used for weighing in a default setpoint Example You want to fill 50 kg into a container After placing the weighing product on the scale the actual weight is shown in the indicator and the additional indicator shows the difference between reference and actual weight by a or sign Function key Function or F key setpoint weight Check display view The additional indicator shows the difference between the setpoint weight and the actual weight by a or sign Taring Taring functions same as for 3 1 Weighing and taring Display option
14. es the Setting mode which helps you to set the scales to meet your specific requirements All information refers to the standard version of the Program Terminal 3020 Differences may occur with special versions 1 2 Description of the appliance Technical data Housing made of stainless steel protection class IP 67 integrated power supply 230VAC optional DC DC converter 12 24 48 V 2 measuring points connectable internally additional measuring points on request Membrane keyboard with a total of 19 keys 1 function key 1 organisation data key alphanumeric keys Display dot matrix 240 x 64 pixels backlit and dimmable Memory capacity fixed value memory for a total of 400 fixed values valid for all programs failsafe alibi memory for 2 million inputs optional Ports 1 x RS 232 additional interfaces optional including bus analogue output 0 20mA Operating temperature 10 C to 40 C Approvable to Precision Class III for n 6000e for multirange and multidivision scales Approvable weighing range 0 1 kg to 120 t Smallest permissible input signal per calibration value 0 25yV Load cell power supply either 5VDC or 5VAC 33Hz ENGLISH a 1 3 Installation and commissioning Before connecting up the appliance make sure that the power supply complies with the specifica tions on the appliance nameplate and the power plug version conforms to local regulations Place the connected scales on a level and stable su
15. gramming and are also assigned to letters upper case or special characters In addition there are special character keys and If you press a numeric key twice within one second this activates the character assigned to this key via a rolling function If you do not press the key a second time within one second the character pressed is accepted and the cursor moves on to the next position Numerical inputs can be made in direct succession without any waiting period as long as the same number key is not pressed several times in succession A cursor flashes under the item to be entered You can move the cursor by using the arrow keys The C key deletes the character to the left of the cursor or the character under which the cursor is flashing the Zero key terminates the input without accepting the new input values the existing values are retained The Print key accepts the input value and returns to the application program Only the default number of characters can be typed into an input box Any further input overwrites the last character 3 0 Application programs The various application programs of the Soehnle Program Terminal 3020 offer you numerous solutions for your weighing operations You can adapt the application programs to your specific needs in Setting mode Please refer to the detailed manual on the CD under the heading Setting mode Below is a list of application programs available to you 1 Weighing an
16. he Tare key You can clear the tare memory in decades by pressing the C key Press the Zeroing key to terminate the display of the tare memory without saving any changes If you want to change the tare memory value type in the new value into the numerical keypad and press the Tare key to accept the manual tare input in the tare memory 3 1 6 Additive tare Taring several even different containers of known weight See the description of the function in the CD manual 3 1 7 Provisional tare Unknown tare values are added to the existing tare memory See the description of the function in the CD manual 3 1 8 Automatic taring Tares the first weight value on the scale automatically See the description of the function in the CD manual 3 1 9 Fixed tare value memory Known tare weights can be saved to a failsafe memory and called when required You can save up to 400 reference weights in a failsafe memory Each memory location has a 3 digit consecutive number description plaintext 18 characters tare weight a Entering tare weights into the fixed tare value memory Press the Print key and the F key simultaneously Setting mode appears in the display The arrow points to Program Settings Confirm with the Print key The arrow points to General Confirm with the Print key Scroll to Fixed tare value using the Tare key and accept with the Print key If no tare memory has yet been assigned the
17. he cause for overload or underload is rectified the scale is zeroed without having to switch the appliance on and off and is ready to operate Response to power failure The scale returns to the previous settings when power is restored Power off Press the On Off key If the activated measuring point is loaded or a menu is open the scale switches off only 3 seconds after the On Off key is pressed Selecting a program Select one of the application programs from the list Call up the setting menu by pressing the Print key and F key press simultaneously The arrow points to Program Settings Press the Print key the arrow points to General Press the Print key the arrow points to Programs Press the Print key the arrow points to the program last selected Select the program you wish to activate by pressing the Tare key or F key Confirm the program by pressing the Print key 2 3 Zeroing a Press the zeroing key to correct minor deviations from the zero point e g caused by soiling on the scale Zero range approvable and non approvable 1 to 3 of the weighing range If zeroing is not possible the error message Above zero range limit or Below zero range limit appears for two seconds in the display gt 06 Zero tracking Zero tracking automatically corrects minor deviations in the zero display 24 X10 display Shows the weight value with an additional decimal point at ten times the
18. ith a negative sign If you press the Tare key again the existing value is overwritten i e a new tare weight placed on the scale is saved The scale can be tared an unlimited number of times until the maximum load is reached The tared weight reduces the maximum weighing range accordingly Clear tare By overwriting with a new tare or 0 or by pressing the Zeroing key Display tare memory Press Info key then press the Tare key You can clear the tare memory in decades by pressing the C key Press the Zeroing key to terminate the display of the tare memory without saving any changes If you want to change the tare memory value type in the new value into the numerical keypad and press the Tare key to accept the manual tare input in the tare memory B 3 1 5 Taring by manual tare input ABC XYZ INFO x Min e 14 Taring a known container weight e g with filled container on the scale Type the known tare weight into the numerical keypad The input appears on the indicator The input is displayed in the activated weight unit Press the Tare key The input is accepted in the tare memory and the tare weight is subtracted from the weight displayed The weight is displayed with the message Net When the scale is clipped off the tare weight is displayed with a negative sign Clear tare by overwriting with a new manual tare input or 0 or by pressing the Zeroing key Display the tare memory by pressing the Info key then press t
19. numeric keypad and confirm by pressing the Print key The arrow points to Tare value Press the Print key the input box for the tare value is displayed Change the tare value in the numeric keypad and confirm by pressing the Print key Return to tare memory selection by pressing the Zeroing key If you want to change other tare memories press the F key of the Tare key to select the next memory location to be changed and repeat the procedure as described above To return to Weighing mode press the Zeroing key and then the ORG key Calling up the list of fixed tare value memories for taring The tare value from the fixed tare value memory can be activated with the scale unloaded i e before the weighing operation or with the scale loaded during a weighing operation 16 A weight value 2 0 000kg appears in the display panel Press the Print key and the Tare key simultaneously The fixed tare value memory last used appears in the display Scroll to the required fixed tare value memory by pressing the F key or Tare key or enter the memory location number and confirm by pressing the Print key Activate the fixed tare value by pressing the Print key The display shows the gross value less the tare value net Further tare values from the memory are activated by repeating the procedure described above Clearing an existing fixed value Press the Print key and the F key simultaneously Setting mode appears in the display The arrow
20. out with the additional information dependent on the print template or they are transferred and deleted as data record Selection options for total display E Function description in the manual Display print and clear total Only display totals Clip off factor when totalising no function when batching In Setting mode you can define see manual whether the scale must be clipped off each time you place an individual piece by 1 to 30 increments Ifthe scale is not clipped off the weight unit is not accepted in the total memory This prevents operations such as saving an item twice Automatic totalising See the description of the function in the CD manual 19 a 3 2 8 Assigning and clearing the consecutive number Every input in the total memory is assigned a 4 digit consecutive number The consecutive number is not reset to the factory setting when the total memory is cleared Optionally you can default resetting the consecutive number in Setting mode deactivated no reset factory setting when the Clear Total key is pressed when the appliance is switched off B 3 2 9 Item counter The item counter only counts operations that are actually totalised The item counter is incremented by 1 each time a new operation is selected by pressing the F key or an automatic totalisation takes place The item counter runs up to 999 then comes an error message The item counter is automatically zeroed when the total
21. points to Program Settings Confirm by pressing the Print key The arrow points to General Confirm by pressing the Print key Scroll to Fixed tare value by pressing the Tare key and accept with the Print key The last selected fixed tare value memory is displayed Scroll to the required fixed tare value memory by pressing the F key or Tare key or enter the memory location number and confirm by pressing the Print key Clear the displayed fixed tare value memory by pressing the C key The gap in the consecutive number scheme is closed The following fixed tare value memories are given a number reduced by 1 ENGLISH 3 1 10 Error message when taring Error 06 Not possible to tare Possible causes Scale empty Scale in overload or underload Manual tare input with tare value above maximum load 3 1 11 Display options with the Info key When you press the Info key you have the following options Tare key Display current tare weight aa a 3 2 Totalising and batching Totalising means that the individual items are weighed one after the other the weight is added in the total memory and the scale is then clipped off again at the end of each weighing operation Batching means that the weighed items remain on the scale the weight is added in the total memory and the scale then returns to zero without clip off It is not possible to change measuring points during a batching operation The choice betw
22. r calling up functions F It assumes different functions depending on how it is assigned The current function is assigned in Setting mode Navigation in Setting mode F t Moves the marking arrow up the list 25 Moves the marking arrow down the list ORG Exits Setting mode Calls the marked menu option m ag Accepts saves an input or change Boc Returns to the next higher level Returns without saving a change c Clears an item ie Moves the cursor one step to the right F Moves the cursor one step to the left ENGLISH Input and control keys The following keys are available for input and control im Numeric keys to type in numerical values ABC XYZ Multiple programming of numeric keys to type in alphabetic characters ORG Calls organisation data c Clears last number INFO E Info key electronic nameplate with reference data ERR nd gt ORG Scale change key press in succession Da Call tare memory Te i Tare key Cursor down Cursor right 0 Zeroing key Print key Enter key DE oc Display The display shows a number of situative views It is divided into display panes ADDITIONAL INDICATOR Additional indicator Displays second units weight values for counting differences with setpoint etc DISPLAY PANE Press the F key to activate as required Symbol bar Displays information on the status of the activated measuring point Display pane Displays weight values quantities unit
23. rface Select an installation site where the appliance is not exposed to shocks vibrations intense heat or cold draughts chemicals and moisture The appliance may only be opened by trained service technicians Before working on the appliance unplug the power supply After power on the measured values will stabilise after a warm up period of 30 minutes Further information on power on is provided in the Operating Manual 3020 on the CD Connections Power supply Ground GND Scale 1 Interfaces 1 2 Pressure compensation membrane Anybus interface A 1 4 Operating concept keys and display symbols The setting options are divided into two function ranges Setting mode Here you can enter user definable settings on the appliance to adapt the weighing system to your requirements For a detailed description refer to Chapter 2 Setting mode in the manual Program settings Terminal Scale Data processing Service General Version Scale parameters Data transfer Only for service Weighing taring Display Alibi memory technicians Totalising batching Keypad Interface 1 Counting Date time Interface 2 Checking Organisation data Print template User password Data processing settings Reset terminal Fieldbus Barcode 4 ENGLISH Program mode Here select the required weighing application program After selecting and activating the application program the scale is ready to operate Function key The F function key is fo
24. s with the Info key When you press the Info key you have the following options F key Displays the current setpoint Tare key Displays the current tare weight ENGLISH 4 Further information a You will find further information on the following subjects in the detailed documentation the Program Terminal 3020 manual on the supplied CD Setting mode Error messages Print Barcode etc ENGLISH ENGLISH FOR MEASURABLE SUCCESS PROFESSIONAL Printed in Germany 11 10 Subject to technical modifications Soehnle Professional GmbH amp Co KG Manfred von Ardenne Allee 12 71522 Backnang Telefon 49 0 7191 34 53 220 Telefax 49 0 7191 34 53 211 E Mail infoGsoehnle professional com 470 051 069 GB SCALES SYSTEM SOLUTIONS AND SPECIAL DEVELOPMENTS www soehnle professional com
25. t and displays 10 pcs Further parts placed on the scale are then counted Function key F Ref Calculating the reference weight from a freely selectable reference quantity Place the reference parts on the scale Press the F key and type in the quantity of parts into the numerical keypad 1 to 99 Press the Print key to accept The scale calculates the reference weight and displays the quantity on the scale Further parts placed on the scale are then counted consecutively 21 Displaying the reference weight Press the Info and F keys in succession Weight display during the counting operation The weight display appears at the top left of the indicator Terminate the count operation by pressing the C key Fixed value memory for reference weights You can save up to 400 reference weight in a failsafe memory Each memory location has a 3 digit consecutive number description plaintext 18 characters article number 18 digits reference weight a Calling the Reference weight fixed value list to edit the fixed values Press the Print key and the F key simultaneously the Setting mode appears in the display The arrow points to Program Settings Confirm by pressing the Print key The arrow points to General scroll to Count by pressing the Tare key and accept by pressing the Print key The arrow points to F key scroll to Reference weight fixed values by pressing the Tare key Press the Print key to ac