Siemens V1.0 User's Manual

image

Contents

1. Warning If you have a firewall installed on your PC it may block the SOFTNET PN IO communications on the Ethernet port In this case ProfinetCommander will not be able to communicate with the PNIO devices 4 0 Configuring the PC Station and the PROFINET IO Network Before starting ProfinetCommander the following configuration steps must be performed Select the IP addresses for the PC and the connected PROFINET IO devices Setup the PC station configuration using the Station Configuration Editor Use the SIMATIC NCM PC or STEP7 configuration tool to configure the PROFINET IO network Download the configuration to the PC station Download the device names to the PROFINET IO devices Export the configuration to a file 4 1 Select the IP Addresses Before starting the configuration process you should select the IP addresses for the PC and the PROFINET IO devices that will be connected so that they are all on the same network and have the same subnet mask For example IP Address Subnet Mask 192 168 1 51 255 255 255 0 IO Device 1 192 168 1 1 255 255 255 0 IO Device 2 192 168 1 2 255 255 255 0 If the Ethernet port on your PC is connected to a corporate network it would be advisable to keep the PROFINET network separate Some options are 1 Use the existing Ethernet port e Disconnect the PC from the corporate network and connect it to the PROFINET network e Change the PC IP address and subnet mask to ma
2. ProfinetCommander User Manual V1 0 July 2006 F A EE r DES EM a Lo F WE Ae Fr D d S d k IN i 1 q j I E i Interface t PROFINET amp PROFIBUS J ProfinetCommander User Manual V1 0 Table of Contents ProfinetCommander User Mant al VT O ottiene eter ad eire Y drea ttv ve eue eee eee 2 UNES I Cclesnie A E S LUTTE 2 20 ATOU CUON dead delit etd ose usage as Rca maha tbe A ee A Ei ME 3 3 0 Hardware and Software Requirements cccccccceccccceeeeeeeeeeseeeeseeeeeseeeesaeeeeseeeseeeeeeas 3 4 0 Configuring the PC Station and the PROFINET IO Network eeeeeeeee 4 4 1 Select the IP Address ES su fae su ccetanenate tae E 4 4 2 Edit tie Station OORDtIgUul allQEls suse cuca eut Gor ctasctace tarot asetantacetnsstaceiuaedanednnetaces caddies 6 4 3 Configure the PROFINET IO Network eeseeeseeeeennennn nnnm 9 4 4 Download the Configuration to the PC Station eeeeseeesseeeeeeeeeeee 16 4 5 Download the PROFINET IO Device Names eeeeeeeneeennnmm 18 4 6 Exporting the Hardware Configuration to a Fil cccccccecccseeeeeeeeeeeeeeseesseesaeeesaeeeeas 19 5 0 Using ProfinetGommandet ode rrr rt Ed Eb eo ee rdc dee xe enis 20 5 1 olan Pronnetcotmlnalh del uie ben tueretur ber E 20 5 2 Opening the HW Gonlig EXDOLE File uere En pora eun ERE Rn Een iran Anan AAR 20 Ho Coniguration DIS Dla Y M 21 5 4 Set
3. Note that the I O data for all the modules under the selected tree item is displayed When in Operate or Clear mode the I O data and status and also the alarms are updated every 500 ms A ProfinetCommander C ProfinetCommander SampleHWConfigExports pcstationpndemo clg i L1 x Open Contig File Read Diagnostics Set Run Mode to Operate a Operate Configuration D Ez Offline Fil PCStation iB 007 IE PE Link D 7D e f 006 SCALANCE X 208 eB 005 abc prt BB 004 ILE PN DIO z BB 002 FL IL BK Jp 001 7 001 Device Name IE PB Link D 7 O SOoALANCE 28 D4ef OO00 GOOD GOOD ogon DOO GOOG0 Gag Dnepadgagpgagagar GOOD GOOD GOOD GOOD ILB PM DIO ITI 51 3PhNI HF I1151 3PN HF Double click cell to I O Data and Status are Change Output Displayed Froperties Froperty Name Froperty Value IP Address Subnet Mask 255 2556 255 0 Slot Number Controller goes to Operate Mode and Devices come online Alarms Q2 708 05 14 17 50 Controller is in OPERATE mode 02 09 06 141757 Device 1 is online 02 09 06 141757 Device 51s online 02 09 06 141767 Device dis online 02 09 06 141757 Device 2 is online 02 09 06 14 17 58 Device is online 02 09 06 1418 01 Device 6 is online 02 09 06 14 16 01 Device 5 submodule return at slot 1 subslot1 02 09 06 14 16 05 Device 3 is online n2 names 3241894101 Dorica A ocukreodiulo raturn atelat eii
4. 0 OF OF 1406 10 46 56 Device 1 Input Address 0 OF 0714 06 10 46 56 Device 2 Input Address 1 OF 071406 10 46 56 Device 1 diagnostic at slot 1 subslot 1 Channel Diagnostic Channel Number Error 17 Sensor or load voltage missing 071406 10 46 55 Device 2 Quput Address 8 OK 071406 10 46 55 Device 2 Input Address 1 OK OF 1406 10 46 55 Device 2 Input Address 9 OF 071406 10 46 55 Device 1 Quput Address 0 OF 07 1406 10 46 55 Device 2 Input Address 1 OK 07 14 06 10 46 55 Device 1 Input Address 0 OF OF 1406 10 46 55 Device 1 diagnostic at slot 1 subslot 1 Channel Diagnostic Channel Number Error 17 Sensor ar load voltage missing OF 14 06 10 46 44 Device 2 Quput Address 9 OF OF 147 06 10 46 44 Device 2 Input Address 1 OF 071406 10 46 44 Device 2 Input Address 3 OF OF 14 06 10 46 44 Device 1 uput Address 0 OF OF 1406 10 46 44 Device 1 Input Address 0 OF OF 14 06 10 46 44 Device 2 Input Address 1 OF OF 14 06 10 46 44 Device 1 diagnostic at slot 1 subslot 1 Channel Diagnostic Channel Number Error 17 Sensor ar load voltage missing 95
5. Network Properties IP address 161 su c TEX co Activate ISO protocol only far H systems subnet mask Standard gateway 18 Jie 1 Ok Cancel Help f Check that the Run Stop column has green indicators If not select the Diagnostics tab to determine the error station Configuration Editor own MEMENTO x Components Diagnostics Configuration Into Station PCStation Made RU IE Index Mame Type Ring Status Run Stoap Cann gt Application Application JE IE General IE General 12 Configuration OK 2i 1 El New diagnostic entry arrived Add Eclit Belete Ring OH Station Mame Import Station Disable Station 4 3 Configure the PROFINET IO Network a Execute SIMATIC NCM PC Manager or STEP7 SIMATIC Manager Create a new project with File gt New Select Insert gt Station gt SIMATIC PC Station Change the name to match the PC station name in the Station Configuration Editor e g PCStation as shown below E PM IU Project C Program Files Siemens step 7s fproj te Station Configuration Editor ONLINE ct Configuration Lomponents Diagnostics Configuration Info PCStation Type 1 Application Application z a d IE General IE General b Next the configuration download interface is set up for the PC Ethernet card Select Options gt Set PG PC Interface 1 PF SIMATIC Manager PN It Project File Ed
6. from the catalog in the right window under the PROFINET IO category to the Ethernet 1 line and insert the appropriate modules in the lower left window as shown below Also when a device is inserted set the IP address as shown below E HW Config PCStation Configuration PN IG CBA PN COPPANDER X mi Station Edit Insert PLC View Options Window Help l x Djela g al He dii eE 22 el Eind mE t sd 1 Application IE General Ethernet PRC Profile Standard 2 FLL E E FROFINET IO Si c Additional Field Devices Eun E LE 49 General ga 1 LL ee io g E Inline T PRI T NS SE BL gg FLIL 24 BE PN PAC 1 0 PP R fgg ILB PN 24 DI 16 DIO16 2T B m Gateway P a IE FB Link FN IO H E IMVLAN PB Link PN IO E General O W SCALANCE X 200 Switches EMEN o BH DEVKIT H E ET 200PRO E 3 ET 2008 E _ GSD S 1 Ikh4151 3PMHHF E Egg 151 3 PN Slot Module Order Number Address 3 add D C j Ww B fa IM151 3 PN BES FSI RERATUGTAET ee o aaj OW am IM151 3 PN 1 PM EDCe4v 6ES7138 4CAO0 0AA0 sd oj Begg IM151 3 PN HF 2 DODC 4V 5AST BES 13 MBBOD DAAD Cid B A 3 BM DIDC24v ST BES 131 4BB00 0AA0 UU OT oii AO 4 DDCA ST BES 131 4BB D DA AD M S ag CP eS SS MM m a B a Jp ques m 7 eee are c og 2DIACT2O
7. Ckri 5 Properties Import Consistency Check Ctrl Alk k Check Gig Compatibility Er AHF Print Ctrl P Print Preview Page Setup Designate an export file name select the Readable format and select Save CONES x Export File C Temp PCStation cfg Browse Options Format Readable C Compact Export default values M Export subnets Cancel Help 19 5 0 Using ProfinetCommander 5 1 Starting ProfinetCommander Start ProfinetCommander either from the Windows Desktop icon or by selecting Start gt Program gt PROFI Interface Center gt ProfinetCommander gt ProfinetCommander 5 2 Opening the HW Config Export File select the Open Config File button and then use the dialog to find and open the HW Config export file that was previously generated for the PC Station gt ProfinetCommander Open Contig e Head Diao Select Run Mode Configuration Devices Select Hardware Config Exported File P 3 x Deszkto E hu Documents hy Computer T t hu Network File name pcstationpndema c a T Files of tupe Contig Files Cancel E 20 5 3 Configuration Display ProfinetCommander reads the HW Config export file and displays the configuration in a tree view in the Configuration window The tree can be expanded to show all the configured items e g PCStation PNIO devices I O modules PROFINET PROFIBUS proxies PROFIBU
8. Mask 255 255 256 0 ce 002 FL IL BK Slot Number 00 Bl Inline Master internal 22 B IL 24 DI 4 ME j Bl B IL 24 DO 32 HD E Bu O01 I4151 3PN HF Bl PM E DC24V Alarms e MB 200 DC24 0 54 ST 02 09 06 09 11 41 Device 6 is online Bill 2D DC24V ST 02 09 06 09 11 41 Device 4is online Bl DI DC 4Vv ST 02 09 06 09 11 43 Device 5 submodule return at slot 1 subslot 1 02 09 06 08 11 48 Device 318 online 02 09 06 09 11 48 Device 5 submodule return at slot 2 subslat 1 02 09 06 09 11 52 Device 5 submodule return at slot 3 subslot1 02 09 06 09 12 17 Device 1 diagnostic at slot 1 subslot 1 Channel Diagnostic 027 09 06 09 12 17 Channel Number 0 Error 17 Sensor or load voltage missing Ik1151 3PhN HF Properties 3 0 Hardware and Software Requirements The following items are required for the ProfinetCommander application to operate correctly e PC with Ethernet port e Siemens SIMATIC NET Networking for Industry CD version 11 2003 SP1 or newer The following software must be installed from the CD SOFTNET PN IO PROFINET IO controller communications software for PC SIMATIC NCM PC configuration tool If Siemens STEP7 is already installed it will be used instead STEP7 V5 3 SP3 or newer is required e Windows operating system supported by the SIMATIC NET CD Windows 2000 XP Professional see CD Before running ProfinetCommander the SIMATIC NET CD must be installed
9. S slaves When a tree item is selected its properties and O data are displayed as shown below Device Number a ProfinetCommander C ProfinetCommander Sample L1 X from Config E Open Contig File Read Jeane Operate Select Hun Mode f Offline Configuration E TR F CStation Device Name Input Status Output status E 007 IE PE Link D 7D PB Link E BB 003 PROFIBUS to QC Port Gate m gi i M 125 M E Bu O06 SCALANCE 200 aie 7 Ps Pon IM151 3PN HE R45 Port Bl R45 Port Bl R45 Port BI RJ45 Port Devices BE RU45 Port i M Bll P145 Port Window o E RJ45 Port ci B8 005 abc prt BI INPUT 002 bytes Devices Properties Bl INPUT 002 bytes Froperty Name Froperty Value Bl OUTPUT 002 bytes IP Address c BER 004 ILE PN DIO subnet Mask 255 255 255 0 iM DIO1E Slot Number kn MM DIE E Bill 002 FL IL BK 8 Inline Master internal Properties I BIL 24 DI 4 ME il B IL 24 DO 32 HD Alarms Window cR 001 IMT5T 3PN HF Bl PM E DC24V vn DO DC 4V 0 5A ST E 2D DC24v ST IBI DI DC2 4v ST Alarms Window Configuration Window 91 5 4 Setting the Run Mode to Operate After clicking the Operate button ProfinetCommander functions as a PNIO controller and establishes communication with the PNIO devices The Alarms window logs each device as it comes online The I O data and status is displayed in the Devices window
10. Save and Compile 4 4 Download the Configuration to the PC Station a Warning If you are changing an existing configuration make sure that ProfinetCommander is not running before downloading or HW Config will lock up b Download the configuration by selecting the icon shown Download c Select OK or Yes to all the dialog pop ups In the Select Node Address window make sure that the Station name field has the PC Station name and the CPU name field has IE General If not then there is a configuration mismatch between HW Config and the otation Configuration Editor and the download will not work Check the PC IP address in both configurations Fix the mismatch and try again Select Node Address x Ower which station address is the programming device connected to the module Stationmanager Select Target Module X Target modules Station name Rack fo Slot Lg must be present Target Station Local C Can be reached by means of gatews Enter connection to target station IP address MAC address Module type Station name CPU name Plant designation fi92 163 1 51 CP IE PCStation IE General Select All Accessible Nodes Cancel Help IE General must be present The following modules will be stopped for loading of the system data Cercei Hee Application IE General Download 13 4363 The module IE General Index 2 is in the S
11. TOP mode Do you want to startthe module now complete restart download Time stamp 72 14 2005 3 07 01 PP 372008 5 28 17 PP 372005 5 27 55 PU 2722008 5 22 43 PI 2722008 5 22 15 PU 2722008 5 22 14 PA 2722008 5 22 10 PA 2722008 5 20 23 PA 2722008 5 18 15 PA 2722008 5 18 15 P2 22008 10 51 5 PA 42008 10 51 4 PA 42008 10 51 4 P2 2 2008 10 51 4 P7 242008 10 51 4 P2 22006 10 51 2 P2 42008 10 51 2 P2 2006 10 51 1 PA 42008 10 51 17 Subsystem Station Manager Station Manager Station Manager IE Converter Proxy Station Manager IE Converter Station Manager Station Manager IE Converter Station Manager Station Manager IE Converter Station Manager Station Manager Station Manager IE Converter Proxy Station Manager A entries w Event The praces The processing of the properties module The processing of the properties module Index 2 The module was reconfigured z default SDB was created for the proxy The component was added at index 2 ir Index 2 The module was entered for co The imported component with index 2 de The component at index 2 was deleted Index 2 The module was removed fram The processing of the properties module The name of the station was taken fram Index 2 The module was reconfigured z The component was added at index 2 ir The component was added at index 1 ir The component at index 2 was deleted Index 2 The module was rem
12. V ST 8 T T g DP slaves for SIMATIC S7 General Parameters listributed rack j eee H 2D Aciz ST I NE O LL oni n x E Pre jx E Gateway IP address Subnet mask ES 255 255 0 f Jo notuse router C Use router Address 192 168 0 2 Subnet not networked ew Properties Delete Cancel Help 14 i Double click each PROFINET IO Device to display its properties and set the Device Name The device name must match the name in the physical device Downloading a name to an IO device is described later If the IP address is not correct select Ethernet to change it Make sure the IP address for IE General and the IP addresses for the IO devices are on the same network addresses match through the subnet mask number of bits Note when the IO controller starts communication with the IO device it will find the device by name and then set the IP address to this configured value x General Short Description ET 2005 Finely graduated modular distributed PO device protection type IP20 Device Name GSO File qsdmil v1 O siemens et200s 20051 007 xml Change release number Node PN IO system Device Number PROFINET 0 System 100 IP Address 182 158 1 105 Ethernet Iz Assign F address via tt Controller Comment Cancel Help 15 j Save and compile the project HW configuration by selecting the icon shown
13. ce name pop down box select the device to be renamed in the Available devices window and then select Assign name Select Device Name Existing Device Name E x Pe vice type Eraems Assign name Assign device name Device name IM151 3PN HF FL IL BK ILE FN DIO Available device dpa IF address MAC address Device type Device name Assign name 151 218 183 104 30 11 02 38 bb ABC PRT abc prt 132 158 1 10 O8 00 06 96 9D 37 SCALANCE 200 Switches SCALAMUE x c Mode flashing test O8 00 06 6B FO AD ET 2008 IM151 3PN HF 8 00 DE BE D CE IE PEB Link IE PBE Link D77 Duration seconds 3 182 168 1102 0D A0 45 02 FB B2 FLIL 24 BK PN PAC FL IL BK O0 40 45 02 FB 0E ILB PN 240116 DIOTBI ILE P DIC Flashing an Bashing off 4 Show only devices of the same type Display only devices without na Update Export Select Device Close Help 18 4 6 Exporting the Hardware Configuration to a File The hardware configuration must be exported to a file The exported file provides the information for ProfinetCommander to display the configuration data and to communicate with the I O devices In HW Config select Station gt Export Ht HW Config PCStation Configuration PN IO CBA PN COMMAN Bly Station Edit Insert PLC View Options Window Help New Ctrl M Open Ckri o Open ONLIME Close Save Save and Compile
14. ion i y y i TE zu Type Ring Stetus _ Run Stop Com 4 pr eee I ams m El m Component ype Application CY IE General Ho OPC Server Add Application Hing DINI d Select Index 2 and use the Add button to add the Ethernet card IE General and select the appropriate card if more than one exists as shown below Station Configuration Editor ONLINE x Components Diagnostics Configuration Into Station PCStation Made RUN P Index Mame Type Ring Status Bun Stoap Conn gt Application Application ig o A SEMEN MEM MEE MENU EN ES CIEN x Type iE General Index f Mame IE General Parameter assig soin Ind Ethernet gt 3Com 30920 Sur acd SUL gt 3Com 3C39e2ll Inte ev ISO Ind Ethemet 3Com 30920 INEO RET o gt eae gt O ICA Select IE General ISO Ind Ethernet gt Dell Wireless WLAN 135 Baard 2 gt TCP IP gt Dell sra ISQ Ind Ethernet sircom Cardbus Etherne TCP IP gt xircom Cardbus Eth Select Ethernet Card s c re I Add elite Delete Bing CIT station Nama Import Station Disable Station OK Help e After hitting OK the component properties of your Ethernet Adapter appear Check the IP address subnet mask and gateway Select the Network Properties button if changes need to be made Component Properties x MAC address 00 05 DB 23 4C E5
15. it Insert PLC View Options Window Help Dilas Pla amp a 95 CE Ba on O Proe Text Libraries roject C Pro LM Display Language Manage Multilingual Texts Rewire Run Time Properties Gompare Blocks Reference Data Ls Define Global Date Configure Network Simulate Modules Configure Process Diagnostics Set PajPC Interface c Select the Ethernet card that is assigned to IE General in the Station Configuration Editor and hit OK Set PG PC Interface X Access Path Access Point of the Application SPONLUNE STEP 5 TCP IP Auto gt irrom Cardbus Ethernet e Standard tar STEF 7 Interface Parameter Assignment Used TCR IP Auto gt lt ircom Cardbus Etherne Properties BS TCP IP gt Xircom Cardbus Etherne Diagnostics HI T CPAP Auto gt 3Com 3C920 Integrated HET CPAP Auto gt 3Com 3C920 Integrated Copy BS TCP IP Auta gt Dell Wireless WLAN 13 B HE TCP IP Autal gt Xircom Cardbus Ethernet v Delete Assigning Parameters forthe IE PG access ta your NDIS CPs with TCE IP Protocol REC DB Interfaces Add Remove 10 d Select the PCStation and then double click Configuration to bring up SIMATIC NCM PC Config or STEP7 HW Config E PM IO Project C Program Files Siemens step7 s7projEe E e Na eise Configuration e Insert the Application and IE General into the configurati
16. lclat 1 5 5 Setting IO Device Outputs As shown in the figure above double click a cell in the Output column of the Devices window to change the output The following dialog will appear Enter a value in the edit window to send constant output values to the IO device Select Increment to make the output count up starting from its current value each 500 ms display cycle Note that there may be multiple output values in the display separated by spaces Each one can be edited for the Manual mode leave the spaces between entries If Increment is selected all of the listed outputs will be incremented Edit Outputs C Increment DU FF Manual Cancel nona 22 5 6 Displaying Diagnostic Alarms When a diagnostic alarm is received from a PNIO Device it is displayed in the Alarms window as shown below At startup ProfinetCommander reads the GSD files for all the devices to get text for the diagnostic error codes The text for the diagnostic error is also displayed if it is available If not consult the manufacturers documentation az ProfinetCommander C Temp pcstationpndemo cfg ES L1 x Open Contig File Read Diagnostics Operate Select Hun Made C Offline Configuration Devices Device Name B IE PB Link D 7D Erein m 003 PROFIBUS to QC Fort Gate SCALANCE X 208 c 006 SCALANCE x 208 0493 0000 GOOD GOOD I Pads Port ILE PN DIO 0000 ooo0 GOOD GOOD Bl R45 Port FL IL BK DBenononon
17. oDOD GOOD GOOD O88 Pu45 Port IMT51 3PN HF GOOD GOOD R45 Port BEL RJ45 Port BL RJU45 Port B RJ45 Port BERUA5 Port ci Bill 005 abc prt BL INPUT 002 bytes E INPUT 002 bytes wo il OUTPUT 002 bytes Properties c Bl 004 ILE PN DIO Property Name Property Value L B DIO 15 IP Address 182 158 1 1 tL DIG subnet Mask 255 255 255 T Bil 002 FLAL BK Slot Number BI Inline Master internal m B IL 24 DI 4 ME Bl B IL 24 DO 32 HD cB 001 IM 151 3PN HF Error Text E PM E DC24V Alarms i 02 09 06 08 11 41 Device 6 is online from GSD File Diagnostic Alarm 02 09 06 09 11 41 Device 4 is online if it exists 02 09 06 09 11 43 Device 5 submodule return at slot 1 subslot1 02 09 06 09 11 48 Device 3 is online 19 06 09 11 48 Device 5 submodule return at slot Z subslot 1 O2 ATE 152 Device 5 submodule return at slot 3 subslot 1 02 09 06 09 1 Z T Device 1 diagnostic at slat 1 subslot 1 Channel Diagnostic 027 09 06 09 12 17 Channel Number 0 Error 17 Sensor or load voltage missing 4 Ld 23 5 7 Reading Diagnostics A diagnostic alarm is sent from the IO device to the controller only when the error occurs Once the controller acknowledges the alarm it is not sent again The diagnostic information is stored in the IO device and can still be read until the error goes away To read the diagnostic errors stored in the IO devices first select a Configura
18. on matching the configuration previously set with the Station Configuration Editor as shown below E HW Config PC Station Configuration PN It CBA PN COMPIMANDER I L1 X mi Station Edit Insert PLC View Options Window Help x Delale S Sale ili E 82 2 ene Find Ee mE PI IE General z i ae Se SEM Profile Standard NU L wa FLL mi SIMATIC 300 n mH SIMATIC 400 EL BAR SIMATIC PC Based Control 300 400 EB SIMATIC PC Station H E Controller A C3 CP Industrial Ethernet mH CP 1411 gg CP 1413 mde CP 1511 B CP 1512 a CP 1604 fi CP 1612 m3 CP 1613 BE CP 1616 Ei e IE General PROFII ra joa fod cr Lp 52 p J E c Ed 1 IMT51 3PN HF Slot Module Order Number Address G address D C RES FSI XRADIHIAGE sb d PM EDC 4v gBES7138 4CAQU AA0 i d epoDce4v 05AST pES 13 4BB00 08A0 oT d spipcesavsT pES 131 4BBO00 04A0 doo Z o Y d 2pipceaysT gpEs 131 4BBO00 08A0 o ee eee H User Application e Application NE SW VB 2 SPI FROFIBUS DP slaves for SIMATIC S7 t M7 and C distributed rack z Press Fl to get Help E 11 f After inserting IE General the following properties screen is displayed Select the New button to create a new Ethernet network normally called Ethernet 1 and hit OK Now ensure that your IP add
19. oved fram default SDB was created for the proxy The component at index 1 was deleted k 17 ail r d If there is an error during the download call up the Station Configuration Editor and select the Diagnostics tab Check the messages at the top that correspond to the time of 4 5 Download the PROFINET IO Device Names a Warning Before downloading PROFINET IO device names make sure that ProfinetCommander is not running or HW Config will lock up b To assign PROFINET IO device names the PC and the IO devices must be physically connected to the Ethernet network and operational c In HW Config select a PROFINET IO device and then select PLC gt Ethernet gt Assign DeviceName zii n HW Config PCStation Configuration PN IO CBA PN COMPMANDER mh Station Edit Insert PLC View Options Window Help Dice 8 e 4 E Download CErl L Upload 0 PE Download Module Identification Upload Module Identification to Fis Faulty Modules Ethernet 1 F Module Information Ctrl D Operating Mode GChl 1 7 2 FL IL f alear Reset Set Time of Day Monitor Modify Update Firmware Save Device Mame to Memory Gard Edit Ethernet Made PROFIBUS verity Device Name Assign Device Mame Save Service Data d Check the Device name column to see if the name is not assigned or has the wrong name If the name needs to be changed select the appropriate name in the Devi
20. ress subnet mask and gateway address if applicable are set properly as they need to match your current Windows settings and select OK when done Properties Ethernet interface IE General R0 52 X General Parameters MAC address Iw _ F protocol is Being used IF address 1 qz 158 1 51 Subnet mask 259 255 255 0 C Use router Address f g2 IER Tos Subnet notnebworked YN New Ethernet Properties Delete Cancel Hep CY Internet Protocol TO IP Prop erties General You can get P settings assigned automatically if your network supports this capability LItherwize po need to aX your network administrator For the appropriate IP settings IP address 132 158 1 Hi Subnet mask 200 e200 99 0 Detault gateway l 12 g Next right click on the IE General Card and insert the PROFINET IO System Hia HW Config PCStation Configuration PN IO Project i0 PC Add Master System Wsconnect Master system Insert PROFINET 10 System Disconnect PROFINMET IH System PROFINET Io Manage Syne Domain isochrone Mode zd Spieciby Modue 2 HEF IE General Filter Assigned Modules Monitor loris Edit Symbols The Ethernet network should now be displayed as shown below i0 PC f al PIE General 2 HEIE General B Ethemet 1 PROFINET I0 Systern 100 CTS h Drag and drop the desired PROFINET IO devices
21. tatus You can get P settings assigned automatically if your network supi ertian this capability Otherwise you need to ask your network adminis ar the appropriate IP settings Speed Obtain an IP address automatically IP address 132 158 1 hl Activity Subnet mask 255 255 255 0 at Sent i Default gateway E LE C E 2s dhe 28 59 btan UNS server address automatically f Use the following ONS server addresses Enter IP address Prefered DNS a eee and Subnet mask Alternate DNS server i Advanced cence Disable Select Properties 4 2 Edit the Station Configuration a b m Execute the Station Configuration Editor by double clicking its icon in the Windows system Tray toolbar It can also be called up from the desktop icon or the Start menu Use the Station Name button to set the station name as desired remember the name because it must be used later when creating the PROFINET IO configuration x Components Diagnostics Configuration Into Station PCStation Made RUN_P Station Name Name Tvpe Ring Status Hun stap Conn 1 2 3 4 5 B T B E 10 11 l2 13 14 15 16 17 18 18 z New diagnostic entry arrived Add Edit Delete Ring OM Station Marne Import Station Disable Station Click to Change Station Name c Select Index 1 and then use the Add button to add an Applicat
22. tch the PROFINET network e Run ProfinetCommander software e When finished connect the PC back to the corporate network e Restore the PC IP address and subnet mask back to their original settings e e e 2 Add a second Ethernet port to the PC Connect it to the PROFINET network Set a fixed IP address and subnet mask to match the PROFINET network Run ProfinetCommander software Set the IP address on the PC using the Windows software Select Start gt Settings gt Network Connections and double click on the appropriate Ethernet connection Network Connections Double click on the 0 x Fie Edit View Favorites Tools Advanced Help Ethernet connection O Back gt a Search Folders la E x p BR Metro Connection ame ype as owswme A LAN or High Speed Internet Local Area Connection LAM or High 5p Connected Broadcom MeExEreme 57xx Gigabit Controller Local Area Connection 2 LAM or High 5p Connected FEM656C 3Com Global 10 100 56K CardBus PC Care Wireless Network Connection LAM or High 5p Mot connected Dell Wireless 1370 WLAN Mini PCI Card wn 4 Ld we Select the Properties button to bring up the IP Properties screen Select Use the following IP address and enter the IP address and subnet mask Select OK in all the dialogs I Local Area Connection Z Status 2 x SEWEREI Support Internet Protocol TCP IP Properties x General Select Connection button S
23. ting the Run Mode to Operate a R nnns 22 5 5 OEN IO DEVi CS OUIDUIS a2 1910 vaa tU d su bu s red Eu efe ctas enar sa Esa Peso Pese seri eee 22 5 6 DISDIAVING DIagmnoslie AlI S uui aeu iai copias Mise uUxU Dico Rr c mre nez eer orien era xeo cu ER Eb RR UVE 23 SAM cies Ie See a ei 24 1 0 Version History Version 1 0 Release 2 0 Introduction The PROFI Interface Center PIC in Johnson City Tennessee has created the ProfinetCommander application which runs as a PROFINET IO controller on a PC with an easy to use graphical user interface With ProfinetCommander the user can test a PROFINET network and the IO Devices connected to it With the Windows graphical interface the user can view the configuration I O data parameters alarms and diagnostic data The output data to the IO devices can also be changed lol x Open Config File Read Diagnostics SUE EUM f Operate Offline Configuration Devices az ProfinetCommander C Temp pcstbationpndemo chg E TER iz CStat in n Device Hame c Bil 007 IE PB Link D D m 003 PROFIBUS to QC Port Gate Ei f 006 SCALANCE x 208 0493 0000 GOOD GOOD E RJ45 Por PNE GOOD GOOD Bl R45 Port BI R45 Part se 8 5145 Port um E 5145 Port x E 5145 Port ied E 5145 Port 0 R45 For ci Bill 005 abc prt BL INPUT 002 bytes m INPUT 002 bytes BI OUTPUT 002 bytes 5 004 ILE PN DIO Property Name Property Value LB DIO 15 IP Address 182 158 151 i BH DI 18 subnet
24. tion tree item The diagnostics for all of the devices under the tree item selected will be read Then select the Head Diagnostics button 22 ProfinetCommander C ProfinetCommands First Select Open Config File Read Diagnostics Config Item Configuration Efl 007 IE PB Link D77D Then Call Up Read ffl 003 PROFIBUS to QC Por Diagnostics Dialog 006 SCALANCE X 208 HRS Port Bl R45 Port BI R45 Port Bl R45 Port E R45 Port Bl R45 Port E RJ45 Port RUS Port ci B 005 abc prt BL INPUT 002 bytes INPUT 002 bytes il OUTPUT 002 bytes c i 004 ILB PN DIO BI DIO 18 E Bill 002 FLJL BK A E nline Master internal j 8 B IL 24 DI 4 ME j ww Ml B IL 24 DO 32 HD SE O01 Ih4151 3PTH HF ds 8 PH E DC24s 200 DC24Vv 0 5A ST 2D OCe4 ST i m L DIDC 24V ST 24 The Diagnostic dialog shown below appears Select the Read Diagnostics button in this dialog each time you want to read the diagnostics The diagnostics have time stamps and are listed in reverse order with the latest message at the top A blank line is inserted each time Read Diagnostics is selected Read Diagnostics Stored in IO Devices Diagnostics Close Diagnostics OF 1406 10 46 56 Device 2 Quput Address 9 OF 07 1406 10 46 56 Device 2 Input Address 1 OF 07 1406 10 46 56 Device 2 Input Address 3 OF OF 47 06 10 46 56 Device 1 Quput Address