Siemens PAPBH User's Manual

image

Contents

1. DJa A NIN gt Rear View of Unit The above table denotes the pin names of the RS 232 port When connecting the pin name at the port is connected to the opposite of that pin name at the destination device PROFIBUS CONNECTION It is recommended that PROFIBUS plug connector such as Siemens part 6ES7 972 0BA00 OXAO be used If the PAPBH is the last unit on the network set the terminating resistor switch to the ON position TROUBLESHOOTING For further technical assistance contact technical support at the appropriate company numbers listed INSTALLATION ENVIRONMENT The unit should be installed in a location that does not exceed the maximum MOUNTING operating temperature and provides good air circulation Placing the unit near The PAPBH can be base mounted or installed using the optional DIN rail devices that generate excessive heat should be avoided mounting kit PANEL MOUNTING DIN RAIL MOUNTING T style DIN rail 4 mounting clips 4 g clip optional Customer supplied 8 4 x 5 16 screws panel mounting screws supplied w optional mounting clips APPLICATION to upstream PROFIBUS Network This drawing shows a typical PROFIBUS Application IN to downstream PROFIBUS Network oN red cam naaa MODEL PAPBH PROFIBUS HOST
2. programming port qos o o connected to HMI o SJELI access to HMI programming port PROFIBUS NETWORK DRIVER APPLICATION NOTE Introduction The PAPBH is a gateway that allows a Paradigm Operator Interface access to a PROFIBUS DP Network The Host Adapter is connected to the Operator Interface programming port allowing data transfer with Internal Communications Blocks The PAPBH is auto configuring for all PROFIBUS properties such as baud rate but needs a Station Address configured by the Operator Interface These are set up using the PROFIBUS Network Driver described here Configuration The Station Address and Input and Output Data Container Blocks are set in the Configuration Edit dialog from the Select Communications Driver dialog The Station Address has a default value of 126 and must be in the range 1 to 125 for normal operation The Input and Output Data Container Blocks are the data buffers that the PROFIBUS Network writes data to and reads data from These correspond to Internal Communications Blocks and as such these must be set up in the Communications Block Table A maximum of 116 words may be transferred per block Data flow is described with respect to the PROFIBUS Network thus Input Data is written to the PROFIBUS Network and Output Data is read from the PROFIBUS Network Example This example shows the PROFIBUS Node configured as
3. The Operator Interface requires an 11 to 30 VDC power supply rated at 2 25 W unless otherwise stated on the label The terminal may take as little as 100 mA in certain circumstances so be sure that the chosen power supply can operate correctly with this load Large switch mode supplies tend to need a certain minimum load before they will operate correctly In any case it is very important that the power supply is mounted correctly if the unit is to operate reliably A very high proportion of reported problems are caused by incorrect power supply installation so please take care to observe the following points The power supply must be mounted close to the unit with usually not more than 6 feet of cable between the supply and the PAPBH Ideally as short a length as is possible should be used The wire used to connect the PAPBH s power supply should be of at least 22 gauge wire If a longer cable run is used you should use a heavier gauge wire The routing of the cable should be kept away from large contactors inverters and other devices which may generate significant electrical noise RS232 PORT PIN OUT Both HMI and PC ports are RS 232 ports and have the same pin out described below The following illustration and table gives the pin out of these ports to enable such connections to be made RJ11 FEMALE PIN NAME a 7 RTS Tx GND GND Rx 1213141516 CTS
4. and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those expressly contained herein The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations Red Lion Controls Red Lion Controls France Red Lion UK Ltd 20 Willow Springs Circle 56 Boulevard du Courcerin Batiment 21 Tapton Park York PA 17402 Z Pariest F 77183 Croissy Beaubourg Chesterfield S41 OTZ Tel 1 717 767 6511 Tel 33 64 80 12 12 Tel 44 1246 22 21 22 Fax 1 717 764 0839 Fax 33 64 80 12 13 Fax 44 1246 22 12 22
5. Kv power EN 61000 4 6 Level 3 10 V rms 150 KHz 80 MHz Electromagnetic RF fields Fast transients burst RF conducted interference Emissions to EN 50081 2 RF interference EN 55011 Enclosure class A Power mains class A Note 1 Self recoverable loss of performance during EMI disturbance at 10 Vrms For operation without loss of performance Install 1 ferrite core RLC FCORO000 or equivalent to power cable at unit 1 0 cables are routed in metal conduit connected to earth ground 7 FIELD CONNECTIONS Removable screw terminal blocks 8 WEIGHT 1 25 lb 0 58 kg STATUS LED s Three LED s provide status indication and are described in Table 1 The PROFIBUS DP state machine is indicated by the data WD and DP LED s and are described in Table 2 Table 1 Paradigm PROFIBUS Host Adapter Status LED Description CACT FUNCTION DATA ern __ DP Data oan state driven by SPC3 DATA_EX pin wo Green Watchdog State Machine State DP Red DP Control State Machine State Table 2 Led Indication of Paradigm PROFIBUS Host Adapter State In PROFIBUS DP Slave State Machine DATA LED WD LED DP LED Red Green Red PARADIGM PROFIBUS HOST ADAPTER STATE OFF ON Baud Search state OFF FLASHING Baud Control State OFF OFF oN Waiting for Parameterization Telegram OFF OFF FLASHING Waiting for Configuration Telegram ON OFF Data Exchange State WIRING AND CONNECTIONS POWER SUPPLY REQUIREMENTS
6. Station Address 5 Communications Block A as Input Data and Communications Block B as Output Data Driver Configuration Communication Block Configuration PROFIBUS DP SLAVE CONFIGURATION COMMUNICATION BLOCKS o DEVICE ADDRESS DATA TvPE sze ACCESS UPDATE LINKS ENABLE Station cores Internal None Ta A Read Auto None Default Input Data Container Block Tebi DI Output Data Container Block Beo EJ Internal None Signed Read Auto None Default LIMITED WARRANTY The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to one year from the date of shipment provided the products have been stored handled installed and used under proper conditions The Company s liability under this limited warranty shall extend only to the repair or replacement of a defective product at The Company s option The Company disclaims all liability for any affirmation promise or representation with respect to the products The customer agrees to hold Red Lion Controls harmless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573
7. he PAPBH has passed the conformance test for PROFIBUS DP Slave Devices Certificate No Z00584 The PNO Identifier for this PROFIBUS device is OxOOFC The characteristics are described in GSD file PCLOOFC GSD A disk containing the GSD file and bitmap is included with each PAPBH DIMENSIONS In inches mm 2 17 55 1 j B 44 6 5 52 140 2 4 97 126 2 _4 CONTROLS DIN rail 4X DIN rail clips optional athe 4X mounting holes for panel mounting Max size 10 screws 2RS232 PORTS FOR HMI AND PC PROVIDES ACCESS TO PROFIBUS NETWORK THRU DB9 CONNECTOR EASILY CONFIGURED USING EDICT97 BASE OR DIN RAIL OPTIONAL MOUNTING STATUS LEDs FIELDBUS TYPE PROFIBUS DP EN 50 170 IMPLEMENTED USING SIEMENS SPC3 ASIC AUTOMATIC BAUD RATE DETECTION IN THE RANGE 9 6 KBAUD 12 MBAUD STATION ADDRESS IS SET BY PROFIBUS NETWORK DRIVER INSTALLED ON HMI PROGRAMMING PORT FREEZE MODE AND SYNCH MODE ARE SUPPORTED CONFIGURATION ALLOWS FOR SINGLE IDENTIFIER AND SPECIAL IDENTIFIER DATA AREA DESCRIPTIONS WITHOUT DATA CONSISTENCY SUPPORT SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer
8. red it Tel 1 717 767 6511 Fax 1 717 764 0839 www redlion controls com Bulletin No PAPBH X Drawing No LP0525 Effective 6 01 MODEL PAPBH PARADIGM PROFIBUS HOST ADAPTER 20060 DESCRIPTION The PAPBH Paradigm PROFIBUS Host Adapter provides a communication channel from a PROFIBUS DP EN50170 Network to a Paradigm Operator Interface HMI The PROFIBUS Network is connected to the PAPBH Paradigm PROFIBUS Host Adapter through a 9 pin sub miniature D type female connector The PROFIBUS Network is isolated from the control electronics using high speed opto couplers and isolated from the supply with a DC DC converter Three LED s provide status information The PAPBH can be base mounted using the 4 holes provided in the base plate or DIN rail mounted using the optional DIN rail mounting kit In normal operation the PAPBH is intended to be connected via it s HMI port to the programming port of the HMI Database download can still be carried out via a connection from the PC to the PC port of the PAPBH All connections are made using standard Red Lion Controls programming cables Configuration is by the PROFIBUS Network Driver installed on the HMI programming port On power up the PAPBH polls the HMI for its Station Address and configuration During start up the PROFIBUS master attempts to parameterize and configure the PAPBH Following start up data is exchanged between the PAPBH and the HMI PNO Conformance and GSD file T
9. the protection provided by the equipment may be impaired CAUTION Read complete instructions prior to installation and operation of the unit A ORDERING INFORMATION MODEL NO DESCRIPTION PART NUMBER PAPBH PROFIBUS Host Adapter Host PROFIBUS Host Adapter PAPEHOOO ae DIN Rail Mounting Kit PAPBHDIN Includes 4 clips and 8 screws Programming Cable P890301Z SPECIFICATIONS POWER REQUIREMENTS 11 to 30 VDC 3 0 W Power Up Current 3 A 2 msec Must use a Class 2 or SELV rated power supply 2 SERIAL PORTS PC Port RS232 on an RJ 11 jack HMI Port RS232 on an RJ 11 jack ProfiBus Port RS485 on a DB9 connector PHYSICAL DIMENSIONS L 5 52 140 2 mm W 4 52 114 8 mm H 1 76 44 7 mm 4 CONSTRUCTION Steel base plate and cover Installation Category I Pollution Degree 2 5 ENVIRONMENTAL CONDITIONS Operating Temperature 0 to 40 C Storage Temperature 20 to 80 C Operating and Storage Humidity 80 max relative humidity non condensing from 0 C to 40 C Altitude Up to 2000 meters w 6 CERTIFICATIONS AND COMPLIANCES SAFETY IEC 1010 1 EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 ELECTROMAGNETIC COMPATIBILITY Immunity to EN 50082 2 Electrostatic discharge EN 61000 4 2 Level 2 4 Kv contact Level 3 8 Kv air EN 61000 4 3 Level 3 10 V m 80 MHz 1 GHz EN 61000 4 4 Level 4 2 Kv I O Level 3 2

Download Pdf Manuals

image

Related Search

Related Contents

SAC-GS2(H24)-Manual  Data Projector - ALLProjectors.RU  Tyan S8010G2NR-LE motherboard  Télécharger le mode d`emploi  Cooper Lighting Sure-Lites EUR Series User's Manual  Instruction n°10-028-M0 du 22 novembre 2010    TAFCO WINDOWS NU2-061S-W Installation Guide  WindMaster & WindMaster Pro User Manual  Panasonic Toughbook CF-53  