Home

Rheem 2-Stage Specification Sheet

image

Contents

1. cem Gas Furnaces Alr RGPE Series de The new degree of comfort Rheem Prestige Series Two Stage Upflow Horizontal Gas Furnace equipped with The Comfort Control System The Rheem Prestige Series Two Stage line of upflow horizontal gas furnaces are designed for utility rooms closets alcoves or attics Because of the furnace s low profile 34 inch 864 mm height the upflow model installed vertically can also be used to satisfy most applications that traditionally call for a horizontal furnace The design is certified by CSA International The Comfort Control System provides over 28 on board diagnostics and fault history codes by detecting system and electrical problems Call for Service alert notification is sent to the thermostat to alert the homeowner of required service Serial Communication Enhanced When installed with a Serial Communicating Condensing Unit and user interface control RHC TST550CMMS 500 Series thermostat this unit offers 4 or 2 wire installation auto configuration and diag nostic messaging with full communicating capability Patented heat exchanger constructed of aluminized steel for the maximum in corrosion resistance and thermal fatigue reliability Low profile 34 inch 864 mm design is lighter and easier to handle and leaves room for optional equipment Energy efficient and quiet ECM 2 communicating motor Improves cooling efficiency when matched with
2. ACCESSORY RETURN AIR CABINETS Return Air Cabinets may be installed on either side application except RXGR C24B side application must be on side opposite gas and AO electrical connections de q e 356 mm er THE RXGR C24B MUST ONLY BE INSTALLED ON THE SIDE OPPOSITE THE GAS AND ELECTRICAL CONNECTIONS 10 29 INTEGRATED HOME COMFORT gt WARNING IMPORTANT NOTICE A SOLID METAL BASE PLATE SEE TABLE MUST BE IN PLACE WHEN THE FURNACE IS INSTALLED WITH SIDE AIR RETURN DUCTS FAILURE TO INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS FURNACE SOLID BOTTOM BASE BASE WIDTH KIT NO PLATE NO PLATE SIZE IN mm IN mm 171 2 445 RXGB D17 21 533 RXGB D21 241 2 622 RXGB D24 AE 61874 02 AE 61874 03 AE 61874 04 151 8 x 239 16 384 x 598 185 8 x 239 16 473 x 598 259 8 x 239 16 651 x 598 RXGW B01 CHIMNEY ADAPTER See Installation Instructions for application limitations FOR HIGH ALTITUDES HIGH ALTITUDE KIT RXGY F13 for all models NOTE High altitude kits do NOT include additional burner orifices If a burner orifice change is necessary they must be ordered through PROSTOCK See Installation instructions for more information CAUTION Always follow National Fuel Gas Code NFGC guidelines when converting furnaces for high altitudes For all installations abo
3. board diagnostics and fault history codes by detecting system and electrical problems Call for Service alert notification is sent to the thermostat to alert the homeowner of required service e Serial Communication Enhanced When installed with a Serial Communicating Condensing Unit and user interface control RHC TST550CMMS 500 Series thermostat this unit offers 4 or 2 wire installation auto configuration and diag nostic messaging with full communicating capability e Patented heat exchanger constructed of aluminized steel for the maximum in corrosion resistance and thermal fatigue reliability e Low profile 34 inch 864 mm design is lighter and easier to handle and leaves room for optional equipment e Energy efficient and quiet ECM 2 communicating motor e Improves cooling efficiency when matched with rated condensing unit and coil e Constant CFM e Seven segment LED for system diagnostics POT ww TODO NAM MA INTEGRATED HOME COMFORT e Diagnostic history for troubleshooting e Dip switch settings for selectable cooling airflow e On demand dehumidification terminal for improved comfort in cooling mode e Convertible from upflow to horizontal left or right e Left or right side gas and electric inlet connections e All models equipped with flame sensor feature an integrated board with humidifier and electronic air cleaner hookups e Insulated blower compartment a slow open gas valve a
4. mm SUPPLY AIR LEFT END 241 2 622 mm FRONT RIGHT END AIRFLOW 257 16 645 mm 2411 32 618 mm a WARNING 111 2 THIS FURNACE IS NOT APPROVED 292 mm OR RECOMMENDED FOR INSTALLATION ON ITS BACK WITH ACCESS DOORS FACING UPWARDS LOW VOLTAGE CONNECTION ELECTRICAL CONNECTION 2613 16 265 8 681 mm 676 mm NOTE In horizontal configuration return air cutout is not permitted BOTTOM VIEW Horizontal Dimensions and Clearance to Combustible Material inches mm MODEL REDUCED CLEARANCES IN mm LEFT RIGHT SHIP WGTS 05 07A 171 2 445 1611 32 415 123 8 314 15 381 21 2 64 0 3 76 0 1125 3176 6 152 110 49 9 078 10 21 533 1927 32 504 141 8 359 181 2 470 21 2 64 0 0 0 1 25 3 76 6 152 120 54 4 241 2 622 2311 32 593 157 8 403 22 559 21 2 64 0 0 O 1125 3176 6 152 140 63 5 NOTES O May require a3 76 mm to 4 102 mm or 3 76 mm to 5 127 mm adapter 2 May be 0 0 mm with type B vent May be 1 25 mm with type B vent Furnaces must be vented in accordance with the National Fuel Gas Code ANSI Z223 1 and or Can CGA B149 Installation Codes and in accordance with local codes Designates Metric Conversions 95 Www gt AS INTEGRATED HOME COMFORT Blower Performance Data RGPE Series de Air Blower Performance Data CFM L s AIR DE
5. specially designed draft inducer motor and blower motor make it one of the quietest furnaces on the market today e Pre paint galvanized steel cabinet e Molded permanent filter e Easy door removal and replacement e Compatible with single or two stage thermostat For optimal performance two stage thermostat recommended Physical Data amp Specifications RGPE Series de Air Physical Data and Specifications Upflow Models U S and Canadian Models RGPE SERIES 05NBMKR 07NAMKR 07NBROR 10NBRMR 12NARMR Motor Fur Load Amps 88 O 86 o o 128 Factory Heating Speed CFM High Fire L s 850 401 1176 555 1305 616 1600 753 1632 865 Nominal L s Range 283 566 283 566 472 755 566 944 566 944 Max ESP In W C Pa F C Low Input mm 400 x 635 400 x 635 489 x 635 489 x 635 578 x 635 Return Air Cabinets C17B C17B C21B C21B C24B Opt RXGR 2 12 x 16 2 12 x 16 2 20 x 16 2 20 x 16 2 24 x 16 Filter Size mm 305 x 406 305 x 406 508 x 406 508 x 406 610 x 406 AFUE O In accordance with D O E test procedures See Conversion Kit Index Form for high altitude derate Designates Metric Conversions Ong wv gt MA INTEGRATED HOME COMFORT Model Number Identification au RGPE Series de Model Number Identification Upflow Models R G P E 07E Rheem Gas Upflow Design Heating Input Designation Furnace Horizontal series Electric N
6. I MA INTEGRATED HOME COMFORT PRINTED IN U S A 10 13 QG FORM NO G11 512 REV 1
7. LIVERY BLOWER SIZE ECM BLOWER EXTERNAL STATIC PRESSURE MODEL RGPE D XW MOTOR H P SPEED INCHES WATER COLUMN kPa INCHES mm W 1 025 8 2 1200 566 11x7 1000 472 279 x 178 800 378 600 283 1200 566 11x7 1000 472 279 x 178 800 378 600 283 1600 755 11x10 1400 661 279 x 254 1200 566 1000 472 2000 944 11x10 1600 755 279 x 254 1400 661 1200 566 NOTE See Coil Specification Sheet for coil data Designates Metric Conversions EO PAKONG gt MA INTEGRATED HOME COMFORT Accessories 29 hir RGPE Series d INTERNAL FILTER RACK FOR BOTTOM OR SIDE RETURN RXGF DA Filters available through PROSTOCK SIDE RETURN FILTER RACK RXGF CA BOTTOM RETURN FILTER RACK FOR UPFLOW APPLICATION RXGF CB FILTER RACK FILTER SIZES7 INCHES mm MODEL RXGF CA RGPE SIDE 153 4 x 25 400 x 635 05 07 AMK 153 4 x 25 07 BRQ 10 400 x 635 12 153 4 x 25 400 x 635 Filter racks are shipped without filters Filters shipped with furnace may be used or a suitable 1 25 4 mm filter Designates E or N RXPF F01 and F02 FOSSIL FUEL KIT is for use with Rheem Heat Pumps and warm air furnaces RXPF F02 also meets TVA requirements RETURN AIR CABINETS FILTER SIZE RETURN AIR CABINETS ra IN mm RXGR C17B 171 2 445 2 12 x 16 305 x 406 RXGR C21B 21 533 2 20 x 16 508 x 406 RXGR C24B 241 2 622 2 24 x 16 610 x 406
8. O Input E Communicating ignition Model BTU HR 05E 05N 50 000 15 kW 07E 07N 75 000 22 kW 10E 10N 100 000 29 kW 12E 12N 125 000 37 kW Designates Metric Conversions 25 IX TODO NAM A Variations A Std Cabinet B Wide Cabinet M Blower Designation M 11x7 279 x 178 mm R 11x10 279 x 254 mm INTEGRATED HOME COMFORT K Heating amp Cooling Designation K 600 1200 CFM 283 566 L s M 1200 2000 CFM 566 944 L s Q 1000 1600 CFM 566 944 L s R Fuel Type R Natural Gas U S and Canadian Standard Furnace 2o Air Dimensional Data TO RGPE Series 11 4 32 mm TOP BOTTOM SUPPLY RETURN 2317 32 253 8 AIR 41 3 AIR 598 mm 645 mm 622 mm FLUE PIPE OPTIONAL CONNECTION AIR INTAKE PIPE CONNECTION F 9 16 14 mm 281 16 A 713 mm 19 32 15 mm B aia 20 19 32 4 19 mm 508 mm 15 mm E _E_ eee a AIRFLOW een he mm GAS CONNECTION 13 8 DIA 35 mm 34 265 8 676 mm ee mm 265 8 676 mm A tm fe gt am AN w wo ab dam ELECTRICAL CONNECTION _14 2411 32 HIGH VOLTAGE 1 411 618 mm LOW VOLTAGE 143 81 365 mm OPTIONAL RETURN AIR CUTOUT 111 o EITHER SIDE FOR USE WITH X 292 mm EXTERNAL SIDE FILTER FRAME i 618 mm 143 8 365 mm 111 2 par mm 15 I I 78 DIA 22 mm l 381 mm 7 8 DIA 22 mm OPTIONAL RETURN AIR CU
9. TOUT I EITHER SIDE FOR USE WITH i EXTERNAL SIDE FILTER FRAME m mo mm mmm kor Woo e e nen 2411 32 IB LEFT SIDE FRONT 1584 mm RIGHT SIDE Both sides for 1800 CFM 8 above Upflow Dimensions and Clearance to Combustible Material inches mm MODEL REDUCED CLEARANCES IN mm LEFT RIGHT SHIP WGTS 05 07A 171 2 445 1611 32 415 12 8 314 O 15 381 21 2 64 0 3 76 0 1 25 3176 6 152 105 47 6 07B 10 21 533 1927 2 504 141 s 359 181 2 470 212 61 0 0 O 1 25 3 76 6 152 120 54 4 241 2 622 2311 32 593 157 8 403 22 559 21 2 641 0 0 0 1 25 3 76 6 152 0 140 63 5 NOTES O May require a 3 76 mm to 4 102 mm or 3 76 mm to 5 127 mm adapter 2 May be 0 0 mm with type B vent May be 1 25 mm with type B vent Furnaces must be vented in accordance with the National Fuel Gas Code ANSI Z223 1 and or Can CGA B149 Installation Codes and in accordance with local codes Designates Metric Conversions gt MA INTEGRATED HOME COMFORT Dimensional Data RGPE Series de Air nro Pommi TOP VIEW if 508 mm 247116 265 38 281 16 621 mm 676 mm 713 mm 13 8 DIA 35 mm Fr A IIR S ITA EAR 3 4 111 2 19 mm 292 mm 143 8 365 mm 2411 32 618 mm 7 8 DIA 22 mm 7 8 DIA 22 mm 5 8 H 16 mm 34 3 4 19 mm 864 mm 2317 32 598
10. er Maintenance Reminder e Temperature Offset e Continuous Fan Hi Med Lo SUPPLY AIR SENSOR For displaying supply air temperature on communicating systems only do not install on non communicating configurations Part 47 24225 01 or equivalent EO PAKONG gt MA INTEGRATED HOME COMFORT Limited Warranty RGPE Series Air de GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated in accordance with the terms of the limited Ten 10 Years Limited Lifetime warranty For complete details of the Limited and Conditional Warranties including applicable terms and conditions contact your local contractor or the Manufacturer for a copy of the product warranty certificate de un MA INTEGRATED HOME COMFORT Notes RGPE Series Air de de un MA INTEGRATED HOME COMFORT Notes RGPE Series Air de de un MA INTEGRATED HOME COMFORT Notes RGPE Series Air de de un MA INTEGRATED HOME COMFORT The new degree of comfort In keeping with its policy of continuous progress and product improvement Rheem reserves the right to make changes without notice Rheem Heating Cooling 4 Water Heating P O Box 17010 Rheem Canada Ltd Lt e e 125 Edgeware Road Unit 1 Fort Smith Arkansas 72917 e www rheem com Brampton Ontario L6Y OP5 NAN
11. n nn nn nn nenn nenn nennen 3 es AAPP AA AA AA ACT SR MARGE RE ERE EEG MR 4 Physical Data Specifications 5 Model Number Identification o ococcococcononcconoconconononnononnononcnnonnnnononnnnonannnns 6 Bliss o KDE MA o UU AA ken 7 Blower Performance Data 2u20004202000020n0n Sonn nn nn nenn nennen nenn nennen nenne nenn 8 ACC ESONGS EA No E 9 EINES YY ANANN RPP e e ES a ee AN 10 Do Www gt NAG INTEGRATED HOME COMFORT TWO SPEED DRAFT INDUCER MOTOR nz PRESSURE SWITCH INTEGRATED FURNACE CONTROL STANDARD EQUIPMENT Completely assembled and wired 2 speed draft inducer high and low pressure switches redundant 2 stage main gas control blower compartment door safety switch solid state time on time off blower control limit control transformer ECM blower motor Furnaces are equipped with cooling heating relay and transformer 50VA ready for air conditioning applications Please note a thermostat is not included as standard equipment Flame sensor diagnostics fused protection secondary EST NM TQ NAAS MA INTEGRATED HOME COMFORT Standard amp Optional Equipment RGPE Series 29 Air d DIRECT SPARK IGNITOR Ma FLAME SENSOR OPTIONAL EQUIPMENT The complete terms of limited and other warranties are available at our sales office or through local installer All models can be converted by a qualified HVAC professi
12. onal or local service dealer to use L P propane gas without changing burners Factory approved kits must be used to convert from natural to L P propane gas and may be ordered as optional accessories from a Rheem parts distributor For L P propane operation refer to Conversion Kit Index Form WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES Model Features au RGPE Series de The Comfort Control System Features The Rheem Dual 7 Segment LED Display easily shows system operating status codes and diagnostic codes The Status Indication System Diagnostics feature thermostat com munication capability and built in diagnostics The thermostat communication capability and alerts the homeowner to any neces sary service requirements Faster more accurate service is provided by the built in diagnostics by pro viding the HVAC professional with dependable information The fault recall feature will allow for the last six fault codes to be displayed and will retain these codes even if power failure occurs In order to save time and money replacement automotive style fuses can be utilized instead of replacing the entire control board Problem Solving Accuracy 100 80 60 E No Diagnostics 40 H Rheem Comfort Control System 20 0 Entry Level Experienced Features of the RGPE Series e The Comfort Control System provides over 28 on
13. rated condensing unit and Coil RGPE Series 80 A F U E T Input Rates 50 125 kBTU tA F U E Annual Fuel Utilization Efficiency calculated in accordance with Department of Energy test procedures e Constant CFM e Seven segment LED for system diagnostics e Diagnostic history for troubleshooting e Dip switch settings for selectable cooling airflow e On demand dehumidification terminal for improved comfort in cooling mode e Convertible from upflow to horizontal left or right e Left or right side gas and electric inlet connections e All models equipped with flame sensor feature an integrated board with humidifier and electronic air cleaner hookups e Insulated blower compartment a slow open gas valve a specially designed draft inducer motor and blower motor make it one of the quietest furnaces on the market today e Pre paint galvanized steel cabinet e Molded permanent filter e Easy door removal and replacement e Compatible with single or two stage thermostat For optimal performance two stage thermostat recommended e A variety of cooling coils and plenums designed to use with Rheem Prestige Series Two Stage gas furnaces are avail able as optional accessories Og wv ww INTEGRATED HOME COMFORT FORM NO G11 512 REV 1 Table of Contents RGPE Series 20 Air d TABLE OF CONTENTS Standard amp Optional Equipment cc cece cece nn nn nn nn nn nn n
14. ve 2000 ft the burner orifice size needs to be recalculated and verified A burner orifice change may still be required See Installation Instructions for more information NOTE For Canadian installations only an optional derate manifold gas pressure reduction method may be used to adjust the furnace for altitude See Installation Instructions for more information This optional method may NOT be used for U S installations U S Models Kit packaged with furnace Requires field installation Designates Metric Conversions Accessories RGPE Series 20 Air d THERMOSTATS RECOMMENDED COMMUNICATING THERMOSTAT For Communicating Configurations only Humidity 25 RHC TST550CMMS CONTRACTOR BENEFITS e Multi Purpose Thermostat Setup Control amp Diagnostics e Auto Configuration No Manual Settings Required in the Field e System History More Accurate Diagnostics e Easy Installation Requires only 4 wires e Diagnostic Messages Service Access to Fault Codes e Blower Adjustment in Heat and Cool e Programmable Fan e USB Interface for contractor contact information and thermostat programming HOMEOWNER BENEFITS e Scrolling System Status e De Humidification Control e Humidification Control e Heat Cool Auto Change over e Qutdoor Temperature Display e Backlight On Off e Intelligent Scheduling Ramp Up Program Anticipation e Audio Notifications On Off e Air Filter UV Lights amp Humidifi