Home

Stearns Recreational 1339 User's Manual

image

Contents

1. Close the Jerk Cord lever so it points toward the Cylinder holder The only part of the lever you should be able to see is where it is attached to the cord 5 Insert Green Pin into the hole that is surrounded by red Make sure the pin passes through the Jerk Cord lever also AE 6 Check CO cylinder If the cap has a hole or is scratched throw it away and get a new one that is not damaged 7 Install the inspected cylinder twisting it in a clockwise direction Twist until the window under the cylinder indicated by C in the illustration turns green 8 Close the lever marked with the CAUTION symbol Be careful not to let it snap down on your fingers 9 Review the Indicator Check instructions below Make sure indicators at locations A B and C are GREEN If you see any RED areas try to rearm the mechanism again a step has been missed or done incorrectly INDICATOR CHECK INSTRUCT OAS rtn ANY RED NST READY SGREEN A B C READY Use REPLACEMENT KIT No 0920 and 0923 22
2. OR CALL 1 800 STEARNS 1 800 783 2767 IN ORDER TO RECEIVE IMPORTANT UPDATES ON THIS PFD 20 REPACKING INSTRUCTIONS Always deflate the PFD and rearm the nflation Mechanism follow REARMING Instructions prior to REPACKING 1 Lay device out flat with the yellow inflatable chamber up Fold right inside edge over as shown exposing velcro strip 2 Fold right outside edge over securing velcro strips 2 Position Jerk To Inflate Tab below bottom edge of PFD as shown Fold left inside edge over exposing velcro strip JERK TO INFLATE TAB LOCATED HERE 3 Fold left outside edge 3 over securing velcro strips Fold right top side over exposing velcro strip Fold left top side over securing velcro strips 4 Snap back strap to shell Secure velcro strap extensions Examine all straps belt keepers adjustment slides and buckles to assure that they are free from twists Check to see that the Jerk To Inflate Tab is hanging free 21 REARMING STATUS INDICATORINST RUCTIONS SECUMATIC 3001S 1 T GECIN PIN A CAUTION SYMBOL 1 Hold the mechanism as shown in the picture above Remove used Cylinder by twisting it in a counter clockwise direction Throw used Cylinder in garbage 2 Carefully lift lever marked with the CAUTION symbol until you hear it click Be careful not to let it snap down on your fingers 3 Carefully insert the Pill into the Pill holder 4
3. PFD over not under clothing Caution bulky clothing may affect the ability of this PFD to turn the wearer to a face up position in the w ater Practice closing hardware and adjusting straps before use or prior to in w ater testing page 14 INFLATED DONNING INSTRUCTIONS Inflatable PFDs can be very difficult to don when fully inflated Deflate through the Oral Tube until enough gas has escaped to don See DEFLATION INSTRUCTIONS on page 9 Don as described above and re inflate orally as described below INFLATION INSTRUCTIONS 1 Manual Inflation To inflate grasp the Jerk to Inflate tab and pull sharply downwards 2 Automatic Inflation The automatic Inflation Mechanism will activate when the device is totally immersed in water Depending upon temperature the device will obtain full buoyancy within 5 to 10 seconds It is recommended that the user regard the automatic system as a backup and always be prepared to pull the Jerk to Inflate tab upon immersion 3 Oral Inflation The Oral Tube is located on the wearer s left side Grasp the Oral Tube and bring to mouth Blow air through the Oral Tube until the Inflatable Chamber is firm If the chamber becomes soft due to CO permeance Oral Inflation will be necessary to maintain full buoyancy 4 Cold Inflation Oral Inflation may be required in addition to manual or automatic inflation if chamber is not firm due to cold temperatures at or below 40 F 4 C Inflation time
4. Your PFD For Damage Make sure that the PFD is free from rips tears or punctures This type of damage on the outside covering indicates that the Inflatable Chamber may have been exposed to potentially damaging elements If these defects expose the yellow inflatable chamber material discontinue use of the PFD until you have the PFD inspected by an authorized repair facility If these defects are noticed but the yellow inflatable chamber material is not exposed the Inflatable Chamber should be checked for leaks The Inflatable Chamber should also be checked for leaks at the beginning of each season and at least every two months during the boating season The leak test procedure is described under USER S INSPECTION Refer to page 11 2 Where and How to Check the Pill Water Sensing Element Examine the inflation mechanism status indicators The Inflation Mechanism Status Indicators will tell you if the inflation mechanism is properly ARMED REARMED and ready for activation The indicators are located on the mechanism at points A B and C as shown on Rearming Instructions on the back cover of this book The mechanism itself is located on the PFD on the wearer s right side Indicator A shows the status of the manual activating lever Be sure indicator Green Pin goes through both the plastic housing and the metal activating lever Indicator B indicates whether a water sensing pill is in place If this indicator is red there is no pill in
5. each season or before a long journey or before each outing as recommended below 1 Physical Inspection of Cover and Straps Examine outer shell fabric seams webbing attachments buckles slides etc Fabric fading can indicate a loss of strength Check for strength by pulling seams and attachments snugly If device shows any signs of damage return to a certified Repair Facility or replace the entire device This inspection should be performed each outing 2 Leak Test This test should be performed every two months and at the start of each season Inflate buoyancy chamber using the oral inflation valve and leave to rest for 16 hours When buoyancy chamber remains firm and full of air there is 11 no leakage and chamber is in operational condition If the chamber deflates immediately bring to a Stearns certified Repair Facility for repair The device is no longer in operational condition 3 Automatic Inflation System This test should be performed during years when the PFD is not inspected by a certified repair facility With device packed as normal immerse the device into a tub of water and see if it inflates DRY REARM and REPACK as shown on back cover of pamphlet 4 Function Test of Oral Valve Remove the dust protection cap With the PFD inflated test the valve by pushing it down using the tab provided on the cap refer to page 9 The valve should depress easily and when released it should automatically return
6. or position Why Automatic inflation after oral inflation could damage the PFD Do not try to alter or modify the mechanism If you are dissatisfied with the humidity resistance or other performance of this product contact Stearns Inc at 1 800 783 2767 Why Altering the mechanism may result in the failure of the device to inflate and provide the necessary buoyancy to float you Why Altering the PFD will void the U S Coast Guard approval for meeting recreational boating carriage requirements You must carry rearming kits to meet the needs of expected conditions of your boating trip Stearns recommends a minimum of two cylinders pins and pills Why If the mechanism is actuated it must be properly rearmed prior to using it again Why To meet the carriage requirements the device must be properly armed unless worn inflated Please read the entire owner s manual for more details about the use and care of this Inflatable PFD ll MANDATORY CARRIAGE REQUIREMENTS Federal regulations in 33 CFR 175 1993 require you to carry Coast Guard approved personal flotation devices PFDs legibly marked with the Coast Guard approval number which are in good and serviceable condition and are the correct size for each person on board To be considered serviceable this PFD shall not exhibit deterioration that could diminish its performance such as broken or deformed hardware detached webbing rotted structural components air leaks or nonf
7. the PFD dry thoroughly REARM and REPACK the PFD in accordance with the manufacturer s instructions HOW DO YOU TEST YOUR PFD USING THE MANUAL INFLATOR 1 Ue test your inflatable PFD you will need Your fully armed PFD and e Rearming kit approved for your PFD This kit contains a water sensing pill that you will need to use following this test Put on the PFD 3 Actuate the inflation system by jerking firmly downward on the pull tab The PFD should fully inflate within 5 seconds 15 Get into shallow water just deep enough that you can stand with your head above the surface See if the PFD will float you on your back or just slightly back of vertical In a relaxed floating position verify that your mouth is well above the water s surface Note the effect of where you hold your legs on how you float Get out of the water and remove the PFD Remove the used CO cylinder from the PFD inflator Completely deflate the PFD using the oral inflator Let the PFD dry thoroughly REARM and REPACK the PFD in accordance with the manufacturer s instructions HOW DO YOU TEST YOUR PFD USING THE ORAL INFLATOR 1 To test your inflatable PFD you will not need any spare parts or rearming kits Remove the CO cylinder and pill to prevent inadvertent activation of the manual inflation system which could potentially damage the PFD Inspect the threaded end to confirm it is un used Put on the PFD Get into shal
8. using CO gas will be longer at these temperatures Activation of automatic system may also be slower Always be prepared to use the manual inflation system See FREEZING TEMPERATURES on page 10 8 ol Other Inflation Precautions Caution Do not fully inflate orally then manually or automatically inflate with the CO2 cylinder Repeated CO2 inflation after oral inflation will damage the PFD to the point that it will not hold air or float e Never inflate this PFD with a Pump or Air Compressor e Permeation loss is greater when the device is inflated with CQz than with air and earlier replenishment by means of the oral inflation system will therefore be necessary REARMING AND INDICATOR CHECK INSTRUCTIONS The back cover of this manual provides the REARMING and INDICATOR CHECK INSTRUCTIONS for the mechanism on your PFD DEFLATION INSTRUCTIONS Depress Oral Valve located inside end of Oral Tube using either the protective cap or tab provided by inserting into the end of Oral Tube see drawing Gently compress air out of the inflatable chamber while depressing the Oral Valve INVERT DEPRESS TO DEFLATE PH DO NOT TWIST OR WRING INFLATABLE CHAMBER TO DEFLATE If for any reason the Oral Valve remains open depress it several times If it does not release discontinue use of this PFD and take it to a certified repair station See page 13 for repair station locations information In an emergency situation hold thumb ove
9. DO NOT REMOVE PRIOR TO SALE OWNER S MANUAL Model No 1339 and 1341 I APPROVAL CONDITIONS and CARRIAGE REGULATIONS This inflatable PFD is approved by the U S Coast Guard for use as a Type V Humidity Sensitive Personal Flotation Device PFD with Type Il performance IT IS APPROVED ONLY WHEN WORN It is not approved for water skiing or other high impact high speed activities This inflatable PFD was designed to be more comfortable and less restrictive to wear than inherently buoyant PFD s When worn used and serviced according to this owners manual this PFD can greatly increase your chances of survival in the water Not recommended for non swimmers or weak swimmers Users of inflatable PFD s must be at least 16 years old See page 2 for CONDITIONS FOR THIS TYPE V APPROVAL CONDITIONS FOR THIS TYPE V APPROVAL This manual automatic inflatable PFD is approved for use as a substitute for a Type II PFD ONLY WHEN WORN Conditional approvals are granted by the Coast Guard for PFDs that 1 Do not meet all the requirements for approval under the Type through IV categories but offer other significant safety features or 2 Have features or uses not found in Type through IV PFDs that require special user knowledge The conditions let the user overcome design traits that would otherwise prevent approval Approved Only When Worn This PFD has the Approved Only When Worn condition on its approval
10. THE AUTOMATIC INFLATOR and the other to carry on board as a Spare Since you should replace the pill water sensing element each year the U S Coast Guard recommends you test the automatic inflation system in the water at the beginning of each boating season By doing this you demonstrate that the automatic inflation system is still working properly and reduce the likelihood of premature inflation and its associated dangers The only check of the manual inflation system with COz cylinder and green indicator tab removed would be to determine that the lever arm and piercing pin move freely when moving the lever attached to the pull tab several times down and up HOW DO YOU TEST YOUR PFD USING THE AUTOMATIC INFLATOR 1 To test your inflatable PFD you will need e Your fully armed PFD and e Rearming kit approved for your PFD 2 Puton the PFD 3 Get into shallow water just deep enough that you can stand with your head above the surface Once the automatic inflator is under water the PFD should automatically fully inflate within 10 seconds 14 See if the PFD will float you on your back or just slightly back of vertical In a relaxed floating position verify that your mouth is well above the water s surface Note the effect of where you hold your legs on how you float Get out of the water and remove the PFD Remove the used CO cylinder and the used pill from the PFD inflator Deflate the PFD using the oral inflator Let
11. because if it is not worn whenever above deck and underway it is less likely to be in working order and cannot be counted as a PFD to meet the carriage requirements on your boat This manual automatic inflatable PFD requires more frequent checks than ones that are inherently buoyant or have manual inflation Wearing this PFD will 1 Provide it the extra attention associated with use 2 Help you address its disadvantages and 3 Increase safety enormously because you have it when needed Read the discussion under SPECIAL CONSIDERATION FOR THE MANUAL AUTOMATIC INFLATOR ON THIS PFD and understand its implications on your safety SPECIAL CONSIDERATION FOR THE MANUAL AUTOMATIC INFLATOR ON THIS PFD Premature automatic inflation creates several risks that you must address to avoid drowning The PFD might not be armed when needed either knowingly or unknowingly Much less common but also important are 1 Double inflation could damage the PFD 2 Inflation when stored in a tight space could damage the PFD and 3 The PFD could inflate when you are in an awkward place or position Owners of inflatable PFDs must understand the unique characteristics of these products so that they can use them safely You must learn how to properly arm the PFD Why An improperly armed mechanism may not inflate the chamber This PFD will not float you without being inflated You must check the status of the mechanism and the CO cylinder b
12. ead out of the water This will greatly lessen heat loss and increase your survival time Use the standard H E L P position when wearing an inflatable PFD Wrap your arms around your torso under the PFD and draw your legs up to a seated position Doing so will help you conserve body heat Keep a positive attitude about your survival and rescue This will improve your chances of extending your survival time until rescued Your will to live does make a difference If there is more than one person in the water huddling is recommended while waiting to be rescued This action tends to reduce the rate of heat loss and thus increase the survival time 18 X EACH OF THESE DEVICES IS INTENDED TO HELP YOU SAVE YOUR OWN LIFE For your PFD to function properly follow these suggestions to verify that it fits floats and remains in good condition 1 Check cylinder cap to be sure it has not been punctured before each use 2 Check the inflation mechanism status indicators before each use 3 Get in the habit of rearming the inflation mechanism right after each inflation 4 This PFD requires rearming with a new cylinder pill and indicators after each inflation Always have rearming kits to service your inflatable PFDs 5 Try your wearable PFD on and adjust it until it fits comfortably in and out of the water 6 Mark your PFD with your name if you are the only wearer 7 Do not alter your PFD If it doesn t fit p
13. efore each outing If the cylinder cap is punctured there will be no gas to inflate the PFD Also if the cylinder is deformed in any way there may not be gas to inflate the PFD Why This PFD will not float you unless it can be inflated Why Are you sure that no one else inflated the PFD recently and did not replace the cylinder Why Premature inflations that occur on a stored product may go unnoticed since the CO gas will permeate the chamber fabric within a few days leaving a deflated chamber Why U S Coast Guard studies have shown high percentages of unserviceable inflatable PFDs with used cylinders in them when used by recreational boaters In addition to inspecting the mechanism and cylinder before each outing you must periodically check the other components of the PFD This would include the chamber webbing buckles and thread Why The chamber may get punctured or abraded to the point where it will not stay inflated Why Over time these components can wear out and not be strong enough to perform their intended function when needed Premature or unexpected inflation of automatic devices may occur in high heat and humidity storage conditions or when exposed to severe conditions such as being innundated by water from waves breaking on deck Premature inflation creates risks you must address Why Inflation when stored in a tight space could damage the PFD Why The PFD could inflate when you are in an awkward place
14. he cylinder is OK you must properly screw it back into the mechanism If the cylinder is damaged discard and install a new undamaged cylinder into the mechanism Additional Notes on CO Cylinders FAILURE to properly rearm the inflation mechanism prior to installing the CO2 Cylinder will result in premature activation of the cylinder CO2 Cylinders are only good for one inflation and cannot be recharged CO2 Cylinders are made with a protective coating that may wear off after a period of use or exposure to the environment When this coating is worn off the CO2 Cylinder may start to show some signs of rusting If this occurs replace the CO2 Cylinder If a gram scale such as a postal scale is available it is recommended to weigh the cylinder to verify that it meets the minimum weight imprinted on the cylinder DONNING INSTRUCTIONS STEP 1 Wear like a jacket inserting arms between straps and fabric STEP 2 Close front buckle Manual pull lanyard should be visible on your lower right side STEP 3 Adjust waist strap through slide located on right side until comfortably snug fit is obtained Tuck free end of belt under waist strap After donning locate the Jerk To Inflate tab for the mechanism It should protrude from the PFD as shown on the pictogram Make sure that you are comfortable locating the Jerk To Inflate tab with either hand Should an emergency develop be prepared to use it Always wear your
15. low water just deep enough that you can stand with your head above the surface If you are a weak swimmer or non swimmer inflate the PFD partially so that you are supported well enough to be able to complete inflation without touching bottom either orally or manually Note this level of inflation because it is the minimum needed for you to safely use this inflatable PFD Fully inflate the PFD using the oral inflator See if the PFD will float you on your back or just slightly back of vertical In a relaxed floating position verify that your mouth is well above the water s surface Note the effect of where you hold your legs on how you float Get out of the water and remove the PFD Completely deflate the PFD using the oral inflator 16 9 Letthe PFD dry thoroughly REARM and REPACK the PFD in accordance with the manufacturer s instructions Vill WEAR YOUR PFD In approximately 80 percent of all boating fatalities the victims were not wearing a PFD Most fatal accidents happen on calm sunny days This inflatable PFD is much more comfortable to wear than other PFD types Get into the habit of wearing this PFD Non swimmers and children especially should wear a hybrid or non inflatable PFD at all times when on or near the water IX HYPOTHERMIA Prolonged exposure to cold water causes a condition known as hypothermia a substantial loss of body heat which leads to exhaustion and unconsciousness Most drowning victims fir
16. manual auto inflator dropping the PFD into the water or exposing the inflation system to unnecessary water spray will result in an inadvertent inflation 10 IV IS YOUR PFD IN GOOD AND SERVICEABLE CONDITION Check your PFD between outings to be sure that it is properly armed that it is free of rips tears or holes that all seams are securely sewn and that the fabric straps and hardware are still strong Inspect the inflatable portion of the PFD in accordance with Care and Maintenance Instructions V CARE AND MAINTENANCE INSTRUCTIONS GENERAL PRODUCT LIFE EXPECTANCY The reliability and service life of this PFD depends greatly upon how it is used and cared for Avoid storing PFD in direct sunlight Sunlight contains ultraviolet radiation that weakens synthetic materials Prolonged exposures to high temperatures and high humidity may shorten service life of this PFD While it is known that these elements degrade the materials every use environment is unique so there is no sure way to estimate how long the PFD will last It is for this reason that you must follow the care and cleaning instructions and perform the maintenance and service checks This will assure that the PFD remains functional and will maximize the useful life of this PFD Failure to follow these instructions rigorously could result in a non functioning PFD causing injury or death INSPECTION User s Inspection The users should perform the following checks before
17. place and the mechanism cannot be armed for manual or automatic inflation until the pill is inserted Indicator C indicates whether the cylinder has been screwed in far enough Note this does NOT indicate the full or empty status of the CO cylinder but only that the CO cylinder is properly seated The color of all Status Indicators have a standard meaning GREEN OK READY RED MECHANISM NOT PROPERLY ARMED NOT READY See Rearming Instructions on back cover of this book The presence of a water sensing pill can be checked by looking at Indicator B The pill itself should be checked regularly To examine water sensing pill lift cocking lever to expose pill and remove If pill is cracked or otherwise damaged replace with fresh pill Examine Your CO Cylinder The CO cylinder contains the gas charge that will inflate your PFD when the inflation mechanism is fired either automatically or manually You must verify that the CO cylinder installed is of the correct size and has not been previously fired To examine the cylinder you must Unscrew it and visually examine the cap the flat surface on the threaded end There are no indicators to show that the CO cylinder is full The cylinder needs to be replaced if there is any visible damage on the flat surface See the product SPECIFICATIONS section on page 5 of this manual to determine the proper size cylinder Proper cylinder size includes both thread size and CO gram weight If t
18. r the valve if it will not close Refer to the back inside cover for REPACKING INSTRUCTIONS FREEZING TEMPERATURES At or below 40 F 4 C automatic activation and inflation time with CO gas will be longer Wearing a partially inflated PFD in these conditions will provide some initial buoyancy while the PFD fully inflates Caution Do not fully inflate orally and then inflate with the CO cylinder Repeated CO inflation after oral inflation will damage the PFD to the point that it will not hold air or float OTHER USE GUIDELINES 1 Always wear your PFD when underway unless you are inside a cabin 2 If you need to jump from any height always fold arms over your chest to keep the PFD in place when entering the water 3 Avoid all unnecessary activities that will be abrasive to the device Use extreme caution around sharp objects 5 Avoid unnecessary exposure to the sunlight See GENERAL PRODUCT LIFE EXPECTANCY on page 11 6 CO gas from the cylinder will permeate through the chamber fabric over time If you are in the water for a long time it may be necessary to top off the inflatable orally by blowing air in through the oral tube 7 Inflatable PFDs are not designed for activities in which the wearer expects to encounter impact with the water at a high speed such as water skiing riding personal water craft etc 8 Inflatable PFDs are not designed for white water activities 9 For Inflatable PFDs that have a
19. roperly get one that does An altered device is no longer Coast Guard approved 8 Your PFD is not intended for use as a fender or kneeling pad 9 If your PFD is wet allow it to dry thoroughly before storing it Store it in a well ventilated area 10 Do not dry your PFD in front of a radiator or other source of direct heat 19 XI ADDITIONAL INFORMATION If you need more information about PFDs and safe recreational boating contact your state boating authority U S Coast Guard Auxiliary U S Power Squadron Red Cross or your nearest unit of the U S Coast Guard or call the Coast Guard Customer InfoLine at 1 800 368 5647 or the Free Boating Course number 1 800 336 BOAT in VA 1 800 245 BOAT or see the USCG Boating Web Page at www uscgboating org DO NOT ATTACH PFD S TO YOUR BOAT Each PFD has straps hooks buckles or other means for securing the device in place on the wearer Some PFDs also incorporate decorative dee rings or tabs Such items are not to be used to attach the device to the boat Attaching the device to the boat will not permit it to perform as intended CO PERMEATION LOSS CO gas will permeate the chamber fabric over time Oral Inflation will be necessary to maintain full buoyancy IF YOU HAVE ANY QUESTIONS ABOUT THE INITIAL ARMING REARMING REPACKING OR NEAREST AUTHORIZED STEARNS REPAIR FACILITY CALL 1 800 STEARNS 1 800 783 2767 PRODUCT REGISTRATION PLEASE MAIL REGISTRATION CARD
20. s Repair Facility REARMING COMPONENTS Unused components for the inflation mechanism should be inspected and or replaced annually VI WHY ARE PFDS REQUIRED SAFETY EQUIPMENT Drownings are the leading cause of fatalities involving recreational boating A PFD provides flotation to help keep your head above water help you to stay face up in the water and increase your chances for survival and rescue Most adults only need an extra 7 to 12 pounds 31 to 53 Newtons of flotation to keep their heads above water The proper size PFD will properly support the weight of the wearer Since this inflatable PFD does not have inherent buoyancy it provides flotation only when inflated Familiarize yourself with the use of this PFD so that you will know what to do in an emergency 13 Vil HOW AND WHY TO TEST YOUR PFD Inflate your PFD and try it out in the water to e Make sure it floats you Comfortably When worn properly Adequately for expected wave conditions Body shapes densities affect performance e Make sure it works A flow of bubbles should not appear See Section V for leak tests It should inflate quick and easily Learn how it works by Activating the CO inflation system Rearming the CO inflation system Using the Oral inflator tube The U S Coast Guard recommends that you purchase two automatic rearming kits one to be used immediately in testing the automatic inflation system see HOW DO YOU TEST YOUR PFD USING
21. st suffer from hypothermia The following chart shows the effects of hypothermia HOW HYPOTHERMIA AFFECTS MOST ADULTS Water Temperature Exhaustion or Expected Time C F Unconsciousness of Survival 0 3 32 5 UNDER 15 MIN UNDER 15 TO 45 MIN 0 3TO4 32 5 to 40 15 TO 30 MIN 30 TO 90 MIN 4 TO 10 40 to 50 30 TO 60 MIN 1 TO 3 HOURS 10TO16 50 to 60 1 TO 2 HOURS 1 TO 6 HOURS 16TO21 60 to 70 2 TO 7 HOURS 2 TO 40 HOURS 21TO27 70 to 80 2 TO 12 HOURS 3 HOURS TO INDEFINTE Over 27 Over 80 INDEFINITE INDEFINITE PFDs can increase survival time because they allow you to float without using energy treading water and because of their insulating properties Naturally the warmer the water the less insulation you will require When operating in cold waters below 60 F 15 6 C you should consider using a coat or 17 jacket style PFD or a Type V Thermal Protective PFD as they cover more of the body than the vest or belt style PFDs Some Points to Remember About Hypothermia Protection 1 Always wear your PFD Even if you become incapacitated due to hypothermia the PFD will keep you afloat and greatly improve your chances of rescue Do not attempt to swim unless it is to reach a nearby craft fellow survivor or a floating object on which you can lean or climb Swimming increases the rate of body heat loss In cold water drown proofing methods that require putting your head in the water are not recommended Keep your h
22. to the closed position and reseal REARMING OF INFLATOR MECHANISM Use Replacement Kit No 0920 and 0923 See Rearming Instructions on back cover for details CARE AND CLEANING INSTRUCTIONS Drying If the device is wet place on a coat hanger to allow thorough drying Do not place in direct sunlight to dry Do not use any heat source or place on radiator Cleaning Damp wipe only with mild detergent recommended for synthetic fabrics Remove grease and oil immediately After every use remove pill prior to rinsing and rinse well with fresh water Read instructions provided on the device DO NOT MACHINE WASH DO NOT MACHINE DRY DO NOT DRY CLEAN DO NOT USE SOLVENT BASED CLEANERS DO NOT BLEACH STORAGE STORE YOUR PILLS WATER SENSING ELEMENTS INA VENTILATED PACKAGE DO NOT STORE INA SEALED CONTAINER e STORE IN CLEAN COOL DRY AREA 12 DO NOT STORE PILLS WATER SENSING ELEMENTS IN HIGH HUMIDITY OR HIGH TEMPERATURES OVER 100 F FOR AN EXTENDED TIME DO NOT STORE PILLS WATER SENSING ELEMENTS FOR MORE THAN 18 MONTHS BEFORE USE REPAIR If you have any question about the condition or integrity of this product call 1 800 STEARNS 1 800 783 2767 A damaged device must be discarded SERVICING Stearns strongly recommends that this device be inspected at least every 24 months by a certified Stearns Repair Facility or STEARNS Inc Call 1 800 STEARNS 1 800 783 2767 for your nearest authorized Stearn
23. unctional oral inflation tube Unless worn inflated this PFD must also be properly armed with a full CO cylinder inflation system status indicator and an accessible manual inflation lanyard A PFD which is approved only when worn or required to be worn must be worn under the specified conditions See CONDITIONS FOR THIS TYPE V APPROVAL page 2 for specific approval conditions of this PFD lil INSTRUCTIONS FOR USE SPECIFICATIONS Chest Size 30 52 inches 76 132 cm Weight Range more than 90 pounds 40 kg Age Range 16 years of age and older Buoyancy minimum 33 7 Pounds 150 Newtons when fully inflated Inflation System Manual Automatic Inflation Mechanism located on your right side Oral Tube located on your left side Pull Tab located on your right side used to manually activate the inflation mechanism and inflate the PFD CO2 Cylinder 33 gram 1 2 inch thread as provided in Replacement Kit 0920 and 0923 Indicators There are three indicators A B and C on the inflation mechanism For the PFD to be fully armed all three indicators must be green and the COz cylinder condition checked PRE DONNING INSTRUCTIONS CHECK THE FOLLOWING BEFORE EACH USE OR OUTING INSPECT PFD FOR DAMAGE EXAMINE THE THREE INFLATION MECHANISM STATUS INDICATORS EXAMINE CO CYLINDER CAP FOR PUNCTURE HOLE IF PUNCTURED OR DEFORMED REPLACE THE CYLINDER READ BELOW FOR MORE DETAILED INFORMATION 1 Inspecting

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書  LRP Hyper Pack 5000    L`attrezzo - spit service  Supermicro 5017C-TF  Antenne satellite automati  Infotainment Navigazione Amundsen Istruzioni d`uso  SHARP SERVICE MANUAL - The Sharp MZ  Tecumseh AVA2490ZXG Technical Data Sheet  Kenmore 596.50009100 Refrigerator User Manual  

Copyright © All rights reserved.
Failed to retrieve file