Home
Raritan Computer P2UMT1664M User's Manual
Contents
1. 255 30 6010 00 Forward Mount The steps correspond to the numbers shown in the front rackmount diagrams 1 Secure the cable support bar to the back end of the side brackets using two of the included screws 2 Slide the user station or KVM switch between the side brackets with its rear panel facing the cable support bar until its front panel is flush with the ears of the side brackets 3 Secure the user station or switch to the side brackets using the remaining included screws three on each side 4 Mount the entire assembly in your rack and secure the side brackets ears to the rack s front rails with your own screws bolts cage nuts and so on 5 When connecting cables to the rear panel of the user station or switch drape them over the cable support bar Front rackmount of a Paragon switch Rear Mount The steps correspond to the numbers shown in the rear rackmount diagrams S Raritan 1 Secure the cable support bar to the front end of the side brackets near the side brackets ears using two of the included screws 2 Slide the user station or KVM switch between the side brackets with its rear panel facing the cable support bar until its front panel is flush with the back edges of the side brackets 3 Secure the user station or switch to the side brackets using the remaining included screws three on each side 4 Mount the entire assembly in your rack and secure the side
2. S Raritan Paragon ll Quick Installation and Setup Guide Congratulations on your purchase of Paragon II devices comprising of analog Keyboard Video Mouse KVM switches and accessory devices that enable users to access and control multiple servers from a set of keyboard mouse and monitor The document provides instructions for basic installation initial login and channel access For more detailed information on the Paragon II products consult the User Guide accessible from the accompanying User Manuals and Quick Setup Guides CD or Raritan website s Firmware and Documentation webpage http www raritan com support firmware and documentation Note The Ethernet port on the Paragon switch is hard coded not configurable and supports only 10 BaseT half duplex Paragon II cover 4 basic types of devices Main Switching Unit Main Unit Stacking Unit Models P2 UMT242 P2 UMT442 P2 UMT832M P2 UMT1664M Models P2 UMT832S P2 UMT1664S User Station Computer Interface Module CIM Models P2 UST P2 EUST P2 EUST C Models P2CIM APS2 P2CIM AUSB P2CIM ASUN and more Paragon Il QSG 1 QSG P2 0J v4 5 E 255 30 6010 00 Raritan Package Contents Paragon Main Unit P2 UMT242 P2 UMT442 P2 UMT832M or P2 UMT1664M e Main Unit x 1 e 20 ft 6 1 m Cat5 test cable x 2 e 6 ft 1 8 m AC power cord x 1 e Rackmount kit including brackets and associated screws x1 e Cat5 admin cable x 1 e Raritan s User Manuals am
3. on all devices in the Paragon II system 2 The Login screen of the On Screen User Interface OSUI is displayed on the monitor connected to the user station Paragon442 Enter Name and Password 3 Type your user name and password in the appropriate fields and press Enter For example if you are the administrator a Type admin in the User Name field and press Enter b Type raritan the default password all lowercase in the Password field and press Enter Note the password is case sensitive Tip You can also type any user name for regular users The factory default user names for regular users are user01 through up to user15 depending on the model of your Main Unit By default there are no passwords for these user names 4 The Selection Menu appears Paragon4d42 o4 CF Son 1 201 T O Page Fkey Ent Esc Paragon II QSG QSG P2 0J v4 5 E 255 30 6010 00 Channels connecting to servers appear in green At first there are no names for any servers so all Name fields are blank Note The only exception is IBM BladeCenter chassis Paragon II shows a default name IBM Blade for the device 5 Press W or A on the keyboard to move the highlight to one of the green channels and press Enter 6 Now you can view and control the chosen server with the keyboard and mouse 7 Press the Scroll Lock key twice QUICKLY to activate the OSUI and do one of the following To choose another green chan
4. IM model Serial RS 232 connector P2CIM SER V P2CIM SER EU V AUATC V P2CIM PWR V for the power strip SUN CIMs CIM model SUN MINI DIN8 connector P2CIM ASUN V USKVMC V CIMs with Special Functions CIM model Automatic skew compensation P2CIM APS2 V P2CIM APS2D V UAL Paragon Il QSG QSG P2 0J v4 5 E 255 30 6010 00 VGA Local connector ports HD15 HD15 HD15 V HD15 VGA Local connector ports HD15 13w3 V HD15 Support Support for IBM for card Blade reader servers CIM model Automatic skew compensation P2CIM APS2 B P2CIM AUSB P2CIM AUSBD V UAL P2CIM AUSB B P2CIM AUSB C P2CIM ASUN V Support Support forIBM for card Blade reader servers V V V
5. brackets ears to the rack s front rails with your own screws bolts cage nuts and so on 5 When connecting cables to the rear panel of the user station or switch drape them over the cable support bar Rear rackmount of a Paragon switch Rear rackmount of a user station Basic Installation Ensure that you have turned OFF all servers and Paragon Il devices prior to installation Installing a basic Paragon IlI system involves these steps Step A Connect Stacking Units to a Main Unit Optional Step B Connect User Stations to the Main Unit Step C Connect Servers to Paragon II Main and Stacking Units Paragon Il QSG QSG P2 0J v4 5 E 255 30 6010 00 Note Users and servers can be located up to 1000 feet 304 m apart However try to limit the cable length between the CIM and Paragon II switch to less than 100 feet 30 5 m for optimal video quality and if possible limit the total cable length between the user and target server to less than 500 feet 152 m for good video quality Step A Connect Stacking Units If your Main Unit supports the use of Stacking Units such as P2 UMT832M you can connect compatible Stacking Units to expand the number of channel ports in the system To connect one or more Stacking Units 1 Connect the power cord to the Main Unit 2 Connect the power cord to the Stacking Unit 3 Depending on the Stacking Unit you purchased use one or two stacking cables to connec
6. nel for verification repeat Step 5 To log out of the system press F9 Video Gain Adjustment A video gain adjustment is available to focus the video image which can be especially useful if you are using an LCD flat panel monitor Please note that you must access each channel individually to adjust that channel s video gain To make the video gain adjustment 1 Press the hot key default Scroll Lock twice QUICKLY to activate the Selection Menu 2 Press the and plus and minus sign keys on the keypad of your keyboard to adjust the video image until it appears to be in focus For P2 UST the video gain range is 15 to 15 Yideo gain changed 03 For P2 EUST or P2 EUST C the video gain setting is named AGC and its range is 0 to 6 _AGC 00 R 0 ILC 3 Press Esc or Enter to quit the OSUI and save the video setting 4 To adjust another channel s video gain setting access it and then repeat Steps 1 to 3 Multi Platform CIM Table PS 2 CIMs CIM model PS 2 VGA Local connector connector ports P2CIM APS2 V HD15 P2CIM APS2DUAL V HD15 P2CIM APS2 B V HD15 5 Raritan CIM model PS 2 connector UKVMC V USB CIMs CIM model USB connector P2CIM AUSB V P2CIM AUSBDUAL vV VGA Local connector ports HD15 V VGA Local connector ports HD15 HD15 HD15 HD15 These USB CIMs also support Sun servers via the SUN USB P2CIM AUSB B V P2CIM AUSB C V ports Serial CIMs C
7. p Quick Setup Guides CD x 1 e Quick Setup and Installation Guide x 1 Paragon Stacking Unit e Stacking Unit x 1 e RUMT 1U LM304 or RUMT 2U LM304 rackmount kit x 1 e 6 stacking cable s the number of cables vary depending on the model you purchased P2 UMT832S Stacking cable x 1 P2 UMT1664S Stacking cable x 2 e AC power cord x 1 Paragon user station P2 UST P2 EUST or P2 EUST C e User station module x 1 e 6 ft 1 8 m AC power cord x 1 e 6 ft 1 8 m AC power extension cord for the connected monitor x 1 e 16 4 ft 5 m DB9 male to female serial administration cable x 1 Paragon IP enabled user station P2 USTIP1 2 e P enabled user station module x 1 e 6 ft 1 8 m AC power cord x 1 e 16 4 ft 5 m DB9 male to female serial administration cable x 1 Rack Mount Paragon Il user stations and most KVM switches can be mounted in 1U 1 75 4 4 cm of vertical space in a standard 19 equipment rack except that P2 UMT1664M switch shall be mounted in 2U 3 5 8 9 cm of space To rack mount a Paragon switch use the brackets and screws that came with the device To rack mount a user station use Raritan s RUST LM304 rackmount kit You can mount a Paragon switch or user station facing the front of the rack or facing the rear Note If you lose or damage a switch s brackets replace them with the RUMT 1U LM304 kit for any 1U switch or RUMT 2U LM304 for a P2 UMT1664M Paragon Il QSG QSG P2 0J v4 5 E
8. t the Stacking Unit to the Main Unit a For connecting P2 UMT832S to P2 UMT832M Plug one end of a stacking cable into the port Expansion Port Out on the Stacking Unit Plug the other end of the cable into the port Expansion Port on the Main Unit b For connecting P2 UMT1664S to P2 UMT1664M Plug one end of the stacking cable into Expansion Port Out A on the Stacking Unit and the other end of the cable into the lower Expansion Port In on the Main Unit Plug one end of the other stacking cable into Expansion Port Out B on the Stacking Unit and the other end of the cable into the upper Expansion Port In on the Main Unit 4 Optional You can cascade up to three P2 UMT832S Stacking Units for a P2 UMT832M Main Unit To add more Stacking Units follow this procedure a Plug one end of a stacking cable into the port Expansion Port In on the last Stacking Unit connected to the Main Unit b Plug the other end of the cable into the port Expansion Port Out on the newly added Stacking Unit c Connect a power cord to the newly added Stacking Unit S Raritan d Repeat Steps a to c if you want to add one more Stacking Unit 5 Turn on all Paragon Il devices 6 Set the total number of connected Stacking Units on the front panel of the Main Unit a Press the FUNC button to activate the Function Menu b Press the A and V buttons to select Stacking Support c Press the ENT bu
9. the user station and turn it on Paragon II QSG QSG P2 0J v4 5 E 255 30 6010 00 3 Connect a PS 2 or USB keyboard mouse and a VGA monitor to the user station Note P2 EUST C provides USB ports only for keyboard and mouse 4 Turn on the monitor 5 Repeat Steps 1 to 4 for all other user stations you want to connect to remaining User Ports The user station does not support the use of a VGA to DVI converter Step C Connect Servers To connect one or more servers 1 Connect a Paragon II CIM to the Main or Stacking Unit a Plug one end of a Cat5 UTP cable into Channel Port number 1 on the back of the Main Unit or any connected Stacking Unit b Plug the other end of the cable into the RJ45 port of the CIM 2 Depending on the CIM model you purchased plug the connectors of the CIM into a server s PS 2 or USB keyboard mouse and VGA ports Tip If the server provides a DVI D connector instead of a VGA port Raritan recommends that you connect the CIM to the server using a Smart View DVI to VGA female to female converter DV 101 Note that currently only the Smart View DVI to VGA converter has been tested and is officially supported by Raritan for use with Paragon Il 3 Turn on the server 4 Repeat Steps 1 to 3 for all other servers you want to connect to remaining Channel Ports Initial Verification To verify that the server connected to the Paragon system can be operated 1 Turn
10. tton to confirm your selection d Press the A and V buttons to select the total number of Stacking Units 3 maximum for P2 UMT832M or 1 maximum for P2 UMT1664M e Press the ENT button to save the setting 7 Seta unique Stacking Unit ID on the front panel of each Stacking Unit a Press the FUNC button to activate the Function Menu b Press the A and V buttons to select Set Stack ID c Press the ENT button to confirm your selection d Press the A and V buttons to assign the numeric ID The guideline of ID assignment is Assign 1 as the ID for the first Stacking Unit which is directly connected the Main Unit Assign 2 as the ID for the second Stacking Unit which is connected to the first Stacking Unit Assign 3 as the ID for the third Stacking Unit which is connected to the second Stacking Unit e Press the ENT button to save the setting 8 Turn OFF all Paragon II devices 9 Turn on the Stacking Unit first If there are multiple Stacking Units turn on the Stacking Units from the last one to the first one in sequence 10 Turn on the Main Unit Step B Connect User Stations To connect one or more user stations 1 Connect a user station to the Main Unit a Plug one end of a Cat5 UTP cable into User Port number 1 on the back of the Main Unit b Plug the other end of the cable into the RJ45 port on the back of the user station B Ee EE Ld o a e 2 Connect a power cord to
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanlei- tung D-Link DUB C2 (DUB-C2) Serial Adapter DIWINE SR - sofralab USB-COM485-PLUS2 Datasheet Caractéristiques du four à micro Port-A-Cool PAC2K24HPVS Fan User Manual H-cell_Manuale Copyright © All rights reserved.
Failed to retrieve file