1. Polycom RealPresence Practitioner Cart 8000 User s Guide P IA v t gt E A ams ur Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Heat Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 althcare 9 2012 Initial Release 3 2013 Call out min power cord size p 18 Update TOC Change transportation storage parameters Include operating parameters p 3 Add patient warning pp 3 and 12 Update images pp 5 6 7 8 Join split Service section p 17 C 4 2013 Changed reflect ANSI AAMI 60601 1 2006 and CSA C22 2 p 18 Polycom RealPresence Practitioner Cart 8000 TABLE OF CONTENTS Warnings Summary 2 Polycom RealPresence Practitioner Cart 8000 Overview 4 General Features 4 Keypad Overview 6 Keyless Entry Operation 7 Manual Override Lock 7 Power Up 8 Polycom HDX 8000 Equipment and Accessories 8 Placing Answering and Ending a Call 9 MultiPoint Video Calls 10 Cameras and Camera Presets 10 Sharing Content 11 Full Screen and Picture in Picture Viewing 11 Custom I O Data Plate Functionality 13 Battery Removal and Replacement 14 Maintenance 16 Cleaning 16 Basic Troubleshooting 17 Service and Support 17 Statement of Use 18 TES Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Polycom RealPresenceQ Practitioner Cart 8000 User Manual p n 1793149 Rev
2. a With the bottom of the battery facing the cart slide the battery into the cart The terminal ends should be pointing out towards the back of the cart CHECK BATTERY LEVEL AND CHARGE Plug unit into wall CONNECT BATTERY LEADS TO BATTERY The control keypad display wil indicate the battery charge level or the battery indicator bars will scroll to indicate that the battery is charging A WARNING Always connect the Red terminal first Do not allow any metal objects or tools to contact a terminal and other metal parts including the other battery terminal at the same c The battery is fully charged when time the charge level bars located inside a Fasten Red Connector Terminal the battery icon stop scrolling using terminal bolt A harmless spark may occur when connector touches terminal Quickly tap connector to terminal to diminish effect b Cover terminal bolt with protective red boot Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 mmm Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 15 Polycom RealPresence Practitioner Cart 8000 MAINTENANCE Unless it is covered in this manual DO A NOT service or make any modificiaton or replace any parts on your cart Only Rubbermaid or an approved technician should service or make modificaitons to the cart DO NOT use the cart if any pieces are m
3. 65W this power rating should not be exceeded To Send PC Content a Make sure your laptop is set up to share from the VGA out monitor port You may need to enable your VGA port with a keyboard command commonly Function F5 or F8 Consult your laptop user manual for instructions for your brand and model Ideal PC screen resolution is 1024x768 Default image to a lower resolution if needed Press the Content button on the remote control Your video feed will be replaced with live graphics from the connected PC Far sites will view your PC content while sharing is activated NOTE If planning on using the audio from your PC you must connect the audio 3 5mm connector from your PC to the Custom I O Panel Rubbermaid x Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 11 Healthcare Polycom RealPresence Practitioner Cart 8000 Sending Content During MultiPoint Calls with Two Monitors By default you will see content in monitor one and the speaking remote site on monitor two If you would like to see all remote sites while sharing PC content open administrative settings on the HDX In the monitor section select Monitor one screen Check Near and Far Uncheck Content Monitor two screen Check Near Far and Content To Stop PC Content and Return to Video Conference e Press the Content button on the remote control Your video feed will resume e You can disconn
4. activation of moving switch very low stopping distances there is no need to have an additional emergency switch MONITOR a The power indicator will illuminate b The generic logo will flash until a video signal is sent to the monitor input NOTE Initially the monitor may identify no signal until the HDX 8000 boots up to a certain point CAMERA a Initially the camera will spin from left to right then to center b The camera image is not displayed until the HDX 8000 is fully booted HDX 8000 a Ablue light will illuminate NOTE The Technology cabinet will have to be unlocked and opened to see light b Initial Polycom splash screen will appear along with series of green LED lights This signifies that the HDX 8000 is booting up Upon complete boot up the display will show the HDX 8000 Home screen As long as the data patch cord has been plugged into the custom I O data plate the Practitioner Cart will be fully operational upon completion of initial setup completed first time Practitioner Cart is turned on and set up Healthcare RealPresence Practitioner Cart 8000 HDX 8000 HARDWARE AND ACCESORIES HDX 8000 e High definition Voice Video amp Content e Flexible audio and video inputs outputs t Polycom EagleEye Camera e rue high definition image capture e Enhanced image quality in all calls not just HD e 12x zoom e 180 degree panning radius e Quick sharp focus when using the
5. manual pan tilt zoom or preset camera locations Multi Function Remote Control e Controls features and functions of the HDX series systems e Uses four 4 AAA batteries included Omni directional HDX Microphone Array e 360 degree coverage e 22 kHz high fidelity audio PLACING ANSWERING AND ENDING CALLS To Answer an Incoming Call Gy Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Polycom RealPresenceQ Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 The system is set to auto answer calls by default If auto answer is turned off e Your system will ring and alert you on screen that you have a call e Press the Call button on the remote to answer the call e Make sure your microphone is not muted unless you wish to remain on mute during the call To Place a Call Gy 1 Make sure the HDX 8000 and display s are powered on 2 Press the Call button on the remote to place a call 3 Adialing window will open on your monitor along the top of the home screen 4 Usethe numbers and arrows on the remote control to navigate to and select the IP address for your call 5 Use the keypad to dial the IP or number of the site you are calling When dialing an IP address use the dot button on the remote control 6 Arrow to the Quality window to select a speed Use the center button as an Enter button 7 You can specify that you are dialing IP or let the
6. system auto detect the call type 8 Press the Call button to dial the call To Hang Up a Call ey e Press the Hang Up button on the remote control If you are in a multipoint call the system will ask you to confirm that you wish to hang up e Use the center button in the arrow pad to confirm hang up e If you are in a Point to Point call the call will drop immediately without confirmation Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Polycom RealPresence Practitioner Cart 8000 Power on off Access system info help menu Share Content Stop Sharing Power Arrows navigate menus amp cameras The center button functions as Enter gt ae ee ar Camera Control olume Contro S Zoom in out ear Camera Control Jac to home main screen T i ackspace Delete Camera Presets Men Picture In Picture Control E Select camera input Access onscreen keyboard A Access address book Dot for IP mM v 7 r0 me Cem re We oucow ption Menu eypad for dialing or selecting camera by its preset ID VCR DVD Control Placing a Call Through the Directory or Call History Lid e Press the Directory button e Arrow to Directory or Recent Call History and press Enter e Arrow to the desired number then the press the green call button to select it e You can also access the address b
7. Aux Audio The Custom I O DataPlate Rubbermaid x Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 13 Healthcare Rubbermaid n Polycom RealPresence Practitioner Cart 8000 BATTERY REMOVAL AND REPLACEMENT A Only use batteries specified by Rubbermaid Medical Failure to do so will void power system warranty Call customer service for details A Do not replace battery in oxygen rich environments as it is possible for sparking to occur Always turn off the cart and unplug the power cord from the wall outlet when removing the battery A There are two conditions when a battery should be disconnected 1 When the battery needs replacing 2 When the cart will be placed into long term storage more than 60 days without use TOOLS REQUIRED 1 Ball End Metric Tool Set 2 10mm Open End Wrench STEPS FOR BATTERY REMOVAL 1 Power Down the System a Turn off any components plugged into cart example PC Monitor b Turn off Power System by Holding On Off switch for 2 seconds LONG TERM BATTERY STORAGE Greater than 2 Months WARNING If cart will not be used for more than 2 months turn off the cart by holding the on off button The battery will need to be recharged every 30 days to prevent damage If you wish to store the battery separate from the cart store battery in a cool dry location UNPLUG POWER CORD FROM THE OUTLET Healthcare 14 REMOV
8. C 03 13 Healthcare Q Polycom RealPresence Practitioner Cart 8000 WARNINGS SUMMARY Unplugging the cart does not electrically de energize the cart hazardous electrical current remains as long as the cart remains powered on To de energize the cart use the power button to turn off the cart then unplug the cart and place the plug in the holder If on off switch is pressed it will power off entire cart even in battery mode In combination with a low speed of movement continuous activation of moving switch very low stopping distances there is no need to have an additional emergency switch Do not position Practitioner Cart to make it difficult to disconnect MAINS power on device Removal of the plug will isolate the device from MAINS The cart power system is designed for powering cart mounted equipment only Do not connect cart mounted equipment into a power source that is not mounted to the cart Do not connect any equipment to the cart which is powered from a separate mains power outlet There is a user accessible mains power outlet provided on the cart for powering devices rated less than 65W this power rating should not be exceeded DO NOT OPERATE the cart or any equipment installed on the cart while the cart is plugged in If the external power cord PROTECTIVE EARTH ground CONDUCTOR is broken or otherwise disconnected The cart and equipment installed on the cart may be safely operated using internal battery power Where the int
9. E BATTERY ACCESS PANEL AND BATTERY ACCESS STRAP a Unplug power cord from battery access panel b Using 4mm hex key or 5 32 remove two fasteners on lower rear panel of battery access panel and place aside c Remove Battery Retainer Strap by depressing the tab on the clasp and unthreading strap from buckle DISCONNECT BATTERY CABLES FROM THE BATTERY a Remove the black boot from the terminal b Use wrench or screwdriver to remove bolt from battery terminal WARNING Do not allow any metal objects or Tools to contact both the terminal and other metal parts including the other battery terminal at the same time c Remove the red terminal cover Use wrench or screwdriver to remove bolt from the battery terminal e Place disconnected cables off to side f Grasp handles on battery and slowly pull out Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 Polycom RealPresence Practitioner Cart 8000 c Fasten Black Connector to black Terminal using terminal bolt d Cover terminal bolt with protective black boot Tuck the excess battery cables into the battery cavity e Place Battery Access Panel back on cart and tighten fasteners with Allen key f Reconnect power cord to Battery Access Panel LEAD BATTERY MUST BE RECYCLED PLACE BATTERY BACK INTO CART
10. ating Environment MUST BE RECYCLED Operating Environment parameters for this system are Temperature 50 to 104 F 10 to 40 C e Humidity 0 to 60 RH non condensing Pressure 700 hPa to 1060 hPa e Altitude 10000ft 3000m max Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 ree Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 3 Polycom RealPresence Practitioner Cart 8000 Polycom RealPresence Practitioner Cart 8000 OVERVIEW The Polycom RealPresence Practitioner Cart 8000 brings High Definition telehealth technology to the patient point of care This solution enables medical professionals to provide patients access to care regardless of time or distance constraints The Practitioner Cart solution is also ideal for broadcasting medical procedures for education or telemonitoring Below is a pictoral overview of the major end items of the Polycom RealPresence Practitioner Cart 8000 GENERAL FEATURES OF THE Polycom RealPresence Practitioner Cart 8000 Polycom Eagle Eye III HD Camera Locking Storage Drawer Custom Camera Mount Spiral Power Cord and Mounting Sound Bar Bracket 24 LCD Monitor Storage Bins Both Sides HDX Microphone Array User Accessible Power Outlet Keypad with LCD Display Located in Technology Tray Locking Technology Tray and Secured Custom I O Data Plate Technolog
11. ce with no applied parts This equipment is designed for continuous operation This device is classified IPXO for water ingress Input 120 VAC 60 Hz 5 1A for North America use 16 AWG minimum power cord type SJT with Hospital Grade or Hospital Only mains power plug Contact Us Polycom Inc 6001 America Center Drive San Jose CA 95164 1 888 248 4143 CHOSE R Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 18 Polycom RealPresence Practitioner Cart 8000 Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Polycom RealPresence Practitioner Cart amp 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 1
12. creen will show you the sites connected into the call e Press the number on the keypad 1 2 3 etc that corresponds with the site you want to disconnect e The system will disconnect the site immediately there will be no secondary confirmation e odisconnect the entire call press the Hang Up button twice or select Hang Up All Using the Directory to Store a MultiPoint Call Ld Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Rubbermaid d Polycom RealPresence Practitioner Cart amp 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 10 What is a Camera Preset The HDX 8000 series can store 100 local camera presets letting you aim and zoom to specific locations with the touch of a button This is similar to the radio presets in a car You may also set camera presets for the far end location if their system supports presets and they allow remote sites to control their camera Presets provide a quick convenient way to move the camera to frequently used positions in the room To Store a Camera Preset e Press the Near or Far button on the remote to let the system know which camera you are going to assign presets to e Adjust the camera position as described above e When at the desired location press and hold 0 9 on the keypad e The camera location will now be assigned to that preset number e To re assign a preset re aim the camera then pre
13. displays on the other monitor Local video can be viewed in PIP on the monitor with the far end Swapping PIP Image with Full Screen e Occasionally you will want to swap the images seen in the small and large windows e Press the Camera button on the remote control e Select the camera already being used to swap the images e Repeat these steps to swap the images back Ending Picture In Picture Display To end PIP display push the Display button on the remote control or place the remote on the table Do not touch the patient and parts of non medical electrical equipment in the patient environment after removal of covers connectors or other parts of the enclosure that could be removed without using a tool A Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Rubbermaid Polycom RealPresence Practitioner Cart amp 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 12 CUSTOM I O DATAPLATE FUNCTIONALITY The Custom I O DataPlate is located on the left side of the Practitioner Cart just below the Technology Tray The I O Panel is designed to take maximum advantage of the input and output capabilities of your HDX 8000 codec The I O connections included on the Custom I O DataPlate are described in the sections that follow Ethernet LAN This is an RJ45 Panel Mount connection This connection is where the LAN patch cord is connected for wired c
14. ect the cable without any harm to your computer open documents open programs or the HDX 8000 FULL SCREEN amp PICTURE IN PICTURE VIEWING Single Monitor Video Viewing When dialing from the home screen you will see the near end video view in a small window Upon connecting the far end will automatically switch to full monitor view Most users prefer to view their local video as well so they know what the far end is seeing during the conference The HDX 8000 series has a built in Picture in Picture support as well as Dual Monitor Emulation Using Picture In Picture with Single Monitor Viewing e Press Display Picture In Picture button on the remote control twice e The PIP window will open with a yellow border around it e While this yellow border is on push the display button to move the viewing window between the four corners of the screen e The PIP border will turn blue when it is locked into position e The PIP window displays what your main camera Is sending to the far end e Ifa far site sends any type of content you will see their content in the main part of the screen and the people on the far end in your PIP window You will lose local view of your room Using Picture In Picture with Dual Monitor Viewing e During video conferences one monitor will show the near end while the other shows the far end e lfafarend site sends PC content the content is displayed on one monitor while far end video
15. egrity of the external PROTECTIVE EARTH ground CONDUCTOR arrangement is in doubt operate the equipment using the internal electrical power source battery DO NOT OPERATE POWER SYSTEM IF WET If your cart becomes wet unplug it immediately wipe off any excess liquid and allow it to dry before using again Do not touch the patient and parts of non medical electrical equipment in the patient environment after removal of covers connectors or other parts of the enclosure that could be removed without using a tool Do not unplug the camera or display power cord while touching the patient Breaking the seal on the lead acid battery to add water will damage the battery and could cause injury EQUIPMENT not suitable for use in the presence of a FLAMMABLE ANESTHETIC FIXTURE WITH AIR or WITH METERED OXYGEN OR NITROUS OXIDE The supplied spiral cord is rated for medical use Connecting the cord to an outlet that is not medical grade indicated with a green dot will not ensure grounding protection Spiral cord power system and cart are for INDOOR use only DO NOT OPERATE OUTDOORS PPPbPbPPPbPPbbPPPPbihb Keep spiral cord away from water DO NOT PLUG CORD INTO OUTLET IF WET Manufactured by Rubbermaid Healthcare 16905 Northcross Drive e Suite 200 Huntersville NC 28078 Polycom RealPresenceQ Practitioner Cart amp 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 2 Polycom RealPresence Practitioner Cart 8000 Inspect spiral c
16. ev C 03 13 i Healthcare 17 Polycom RealPresence Practitioner Cart 8000 STATEMENT OF USE The Polycom Practitioner Cart Telemedicine system is intended for operation by a professional healthcare provider The Practitioner Cart may be used to achieve the following a Enable a remote clinician to consult with patients and make a diagnosis D Enable a professional healthcare provider to have real time images and audio sent and received from medical devices to allow a remote clinician to review the images diagnose and provide care from a distance C Transport real time images of patients images and sounds from medical devices for educational purposes Indications for Use The Polycom Practitioner Cart is indicated for use in real time video consultation for acquisition communication and display of medical images The system transfers synchronous real time video and sounds between the clinician and the patient Medical devices approved by governance of the local authority can be used to provide real time medical images and sounds to the system to enable remote clinicians to offer high level assessment and diagnosis Clinicians can also contact patients directly through the video conference connection The communication connectivity is via a standard public telecommunications utility to the Internet Decisions concerning diagnosis and treatment are solely performed by the remote clinician Depending on
17. issing or if there is any damage to the cart In these cases immediately contact Rubbermaid Customer Service for more information A Cables Always keep the cables neatly organized and be sure to route excess cables away from moving components with wire tires or cable clips Casters To ensure that the cart travels smoothly check the casters periodically to make sure they are free of debris and clean Keep the cart away from uneven dirty or damaged surfaces Fasteners If fasteners become loose please notify Rubbermaid Customer Service If fasteners need to be tightened do not over tighten screws In addition to damaging the screw components can be damaged Spiral Cord Periodically inspect cord and plug to ensure plug is not bent and cable is not frayed CLEANING CAUTION e X Verify that your cart is turned off and unplugged from the wall outlet before cleaning e Allow your cart to dry completely before plugging the power cord into a wall outlet e When cleaning the cart wipe cleaners off of surface with a damp cloth and thoroughly dry e Never cover the cart or its components in liquid or allow liquids to flow into the cart e Never use steel wool or other abrasive material as these could damage the surface finish e Before using any cleaner on the cart first test on a small area to ensure that the surface is not harmed These guidelines cannot guarantee infection control The hospital s Infection Con
18. locks are in the unlocked up position Examine casters to see if any debris is caught in them Polycom RealPresence Practitioner Cart 8000 Keyless Entry System Does Not Work e Check the battery charge If at 0 recharge the battery by plugging in the power cord into a working medical grade outlet e Verify the code that you are inputting into the system is the proper access code e lf this persists contact the Polycom Service Department SERVICE AND SUPPORT Service Level Commitment Polycom is committed to providing best in class service This document details our standard warranty and instructions on how to request service using our customer support system Service Details Components generally requiring on site technical assistance may include but are not limited to cart electronics lift mechanism power system locking mechanism and structural failures Components that generally do not warrant on site technical assistance may include but are not limited to power cord drawers battery replacement and casters REPLACEMENT PARTS AND OR TO REQUEST SERVICE FOR THE Polycom RealPresence Practitioner Cart 8000 Please call us at 1 888 248 4143 Address Polycom Inc 6001 America Center Dr P O Box 641390 San Jose CA 95164 Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 mme Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 R
19. lycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 5 Polycom RealPresence Practitioner Cart 8000 KEYPAD FEATURES Message Center Battery Level Indicator Indicates status of Battery indicator will alarm at locking system and 20 remaining life Immediately plug in cart and Up Down Arrows Used to raise and lower the work surface LCD Contrast Adjustable by battery charging status Alarm willgo oti repeatedly pressing the SETUP key and UP DOWN arrows at Lock Button Secures the same time locking system Power Button O O LocK urr O4 O UNLOCK LIFT Press and hold this button to shut Clear Button off all cart power edi Clears entry if This should be mistake is made done only if the when entering PIN cart will not be plugged in or Mute Button Press button to used for an mute alarm when battery Keyboard Light extended period reaches 2096 If battery Automatically of time or the reaches 1096 mute will not shuts off after a first time the cart work Cart must be plugged preset time is used in Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Polycom RealPresenceQ Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 6 KEYLESS ENTRY OPERATION Keyless entry includes a numeric keypad on the top of the user interface containing the digits 0 9 for user entry into the drawe
20. medical devices being used a trained and qualified medical professional healthcare provider working within the scope of their license should facilitate and assist patients with use of the Polycom Practitioner Cart and medical devices Contraindications This product is not intended for use in life sustaining or life saving applications The Polycom Practitioner Cart does not provide an alternative to contacting emergency services if a patient has a health problem that requires immediate attention Compliance Classification This product is a Class 1 Medical Device Data System MDDS ANSI AAMI ES60601 1 2005 R2012 Medical electrical equipment Part 1 General requirements for basic safety and essential performance Amendment No 2 2010 05 30 CAN CSA C22 2 No 60601 1 2008 Medical electrical equipment Part 1 General requirements for basic safety and essential performancelEC 60601 1 2 Collateral Standard Electromagnetic Compatibility Requirements and tests All configurations of the cart shall comply with the requirements of UL 60601 1 2003 Anybody connecting Medical Equipment to this cart is responsible that the system complies with the requirements for Medical Electrical Systems Attention is drawn to the fact that local laws take priority over the above mentioned requirements If in doubt consult your local representative or the technical service department Class A Group 1 ISM Equipment Internally powered devi
21. onnectivity to your Practitioner Cart Input VGA This is a VGA female Panel Mount connection This connection is designed to plug into your laptop to allow for PC Content sharing Input DVI Connected to Second Display Out Ethernet LAN S Video Connected to split S Video Input 3 5mm F Connected to PC audio Composite Video Connected to split S Video Input Connection Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Polycom nci Presence Practitioner Cart 8000 S Video This is an S Video female Panel Mount connection This connection is designed to connect a document camera video camera or any peripheral that requires an S Video connection and analog video Input Composite Video Yellow This is a Composite RCA female barrel connection This connection is for analog video connections such as VCR s and DVD s Input Composite Audio Red and White There are two Composite RCA female barrel connections These connections allow auxiliary audio from a camera PC or VCR DVD player Input DVI This is a DVI female Panel Mount Connection This connection is designed to attach toa projector or a secondary display to emulate or expand your views within a conference Output a HDMI USB 2 0 Connected to PC Inputs USB 3 0 Connected to PC Inputs VGA Connected to PC Input Composite Audio Connected to
22. ook with the green Directory button Volume and Mute Control e Use the Volume button on the remote control to adjust the call volume e fthere areg audio issues o Check that the audio sound bar power light is on o Turn up audio sound bar to full volume Press the button repeatedly e To mute the microphone press the mute button on the remote control e The button in the center of the HDX microphone array will also mute the system e Red lights appear on the microphone amp a muted microphone icon will appear onscreen e To unmute press the mute button on the remote or the HDX microphone array Rubbermaid Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 9 Polycom RealPresence Practitioner Cart 8000 e Press the Directory button on the remote or arrow to Directory on the home dialing screen e Select New e Select MultiPoint e Select the participants and speed for the call and assign a name to the group e Future calls to the group can now be MULTIPOINT VIDEO CALLS made by selecting the group from the address book MP Plus is available for the HDX 8000 series and included with some models bundles If your Using an External Bridge system has MP Plus it s a built in four port MCU that is activated with the purchase of a MultiPoint If you connect or bridge more sites or if you do Plus Software License Key HDX 8000 system
23. ord before each use DO NOT USE CORD IF DAMAGED Fully insert spiral cord plug into outlet DO NOT unplug by pulling on cord DO NOT remove bend or modify any metal prongs or pins of spiral cart cord DO NOT use excessive force to make connections DO NOT ALLOW CORD TO OVERHEAT DO NOT drive drag or place objects over spiral cord Do not stand or walk on spiral cord Only authorized personnel experienced in servicing electrical equipment should open the power system Do not use an electrical extension cord with your cart pb PPPPbP Use caution maintain control of the cart while moving the cart over thresholds Signal Word Level of Hazard Symbol Indicates a situation that does not present any IMPORTANT hazard but is very important in maintaining a well functioning cart Consult accompanying document to avoid a ATTENTION potentially hazardous situation which may result in minor or moderate injury Indicates an impending electrical hazard which if ELECTRICAL not avoided may result in personal injury fire and or death Polycom Take Back and Transport Storage Recycling Program Care should be taken to transport and store this CART DISPOSAL system within a temperature range of 4 to 131 F Dispose of carts in accordance with local 20 C to 55 C Humidity 0 RH to 90 RH environmental guidelines and regulations for non condensing waste If further information is required please contact LEAD BATTERY TakeBack polycom com Oper
24. outlet Check to ensure power cord is plugged securely into back of cart Check to see if the keypad control display shows that the cart is charging when plugged in If the charge level is critically low the keypad control will display battery low recharge If the cart does not start check to see if the cables to the power supply interface are securely plugged in Cart will Not Charge Check to ensure external spiral cord is plugged into base of cart Ensure the outlet the cart is plugged into is functionally operational Plug the power cord into a working hospital grade outlet Check to make sure the power cord is plugged securely into the back of the cart Check to see if the LCD display indicates the station is charging when plugged in If the charge level is critically low LCD will display battery low recharge If the cart still does not charge check to see if cables to the power supply interface are securely plugged in Audible Alarm will Not Turn Off When the battery reaches approximately 1096 of capacity remaining the audible alarm will sound The alarm may be muted for 1 minute Until the cart is plugged in to charge the audible alarm will continue to sound every minute If alarm fails to shut off after plugging in cart for several minutes turn off the unit by holding on off button for 2 seconds If this persists contact the Polycom Service Department Cart Is Hard To Push Check that the caster
25. r Each time a number is pressed a corresponding will appear on the LCD display verifying that a number has been pressed Upon entry of a correct code the unit will unlock the drawers and the message DRAWERS UNLOCKED will appear on the LCD display g E593 3535 009 9000 If an invalid code is entered the message ERROR INVALID CODE will appear The unit will automatically relock the drawer according to a preset time ranging from 1 255 seconds 98900 00007 C989 98000 LOCK allows the user to lock the drawer before the automatic relock occurs CLEAR button is provided to allow the user to clear the numeric entry if he or she enters or starts to enter an incorrect code Keyless entry models can be programmed with up to 128 access codes Polycom RealPresence Practitioner Cart 8000 The drawer is designed so that it can be removed from the unit The unit may auto lock with a drawer removed The drawer may be reinserted into a locked unit without unlocking the unit When a drawer is fully inserted into a locked telemedicine cart the newly inserted drawer will be locked The electronic keyless entry unit will only work when the unit and the battery are charged to an operating level MANUAL OVERRIDE LOCK The keyless entry system is equipped with a redundant manual lock that is located on the back of the cart The manual lock allows the drawer to be unlocked when the unit is use during a low
26. s not have a MultiPoint License you can connect can be upgraded to 8 ports This license allows your videoconference over an external bridge you to connect up to three or seven far sites to There are many bridging services available one conference and supports mixed IP and ISDN endpoints Once you have activated the MultiPoint License in your HDX 8000 series it s CAMERAS AND CAMERA easy to make a multipoint call You can add participants at any time during your conference PRESETS and can disconnect individuals or all sites at any time Controlling the Near and Far End Cameras Gy e Press the Near or Far button on the Adding a Site to a MultiPoint Call remote control e The on screen camera icon will point e Call the first site as described in section towards you if controlling the near end Making a Call camera or away from you if you are e While in a call press the Call button on controlling the far end camera the remote e Use the arrows on the remote to move e Dial the number you wish to call or select the camera up down and left right it from the address book e The Zoom In Out button will zoom the e Repeat these steps until all sites are image as desired connected NOTE Some system administrators will not E allow far end camera control Disconnecting a Site in a MultiPoint cal O While in a MultiPoint call you can disconnect sites one at a time at any time during the call e Press the Hang up button e The disconnect s
27. ss 0 9 This will override the existing preset e Toclear all Presets press Near then select delete e When you power on the system it will default to the preset position O Using Camera Presets e To view your presets press the Preset button on the remote e During a conference press 0 9 to move the camera to its preset position e The camera can be controlled with the arrows and zoom button after being moved to a preset location This will not affect or change your preset assignments Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Polycom RealPresence Practitioner Cart 8000 Displaying a Secondary Camera or DVD VCR If you have purchased a secondary camera or DVD VCR it can be used during video conferences Arrow to the secondary camera S Video or DVD VCR Composite icon and then press Enter To return to the main camera repeat the above steps selecting the first icon SHARING CONTENT Connecting a Laptop or PC You can connect your PC directly into the VGA input connection on the Custom I O Panel on the left side of the Practitioner Cart allowing you to share live PC graphics during a videoconference This is called content sharing A Do not connect any equipment to the cart which is powered from a separate mains power outlet There is a user accessible mains power outlet provided on the cart for powering devices rated less than
28. trol administrator should be consulted for cleaning procedures and processes RECOMMENDATIONS e Clean plastic components with diluted non abrasive solutions Suggested cleaners are water soap diluted bleach and alcohol solutions e Remove pen and dry erase marker stains with a soft cloth and 9196 isopropyl alcohol e Remove iodine stains with a soft cloth and any cleaners suggested above DO NOT use the following chemicals to clean your cart Acetone Mineral Spirits Abrasive Cleansers Paint Thinner or any other harsh or toxic chemicals CLEANING OF HIGH TOUCH POINT ITEMS 1 Work Surface is fully removable to facilitate cleaning see Step 1 of Startup instructions 2 Document Protector is removable for cleaning by pulling up on back corners To replace press nylon fastener into hole in work surface Document protector is a replaceable item 3 BackHandle is fully removable see Step 9 of Startup instructions 4 Rear Bins can be removed by grabbing outside edge of bin and lifting up 5 Keyboard Tray and Mouse Pads Tray and mouse pads are composed of melamine resin and are easy to wipe down Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Rubbermaid d Polycom RealPresence Practitioner Cart amp 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 16 BASIC TROUBLESHOOTING Cart will Not Power Up Plug power cord into working medical grade
29. voltage shutdown The hard lock is located on the rear panel of the cart The rotary latch hard lock has two positions The key is included in the extra parts kit position unlocks the drawers The key Position 1 is the unlocked position This i cannot be removed Position 2 is the normal operating position It enables the keyless entry System to operate SETTING CODES see Control Board Software Manual Default code 1234 Note Lock codes and the auto lock down timer are set using control board configuration software available to administrators and authorized technicians Contact your service representative to acquire a copy of the configuration software and manual The configuration software is also available for download at www rubbermaidtelemedicine com welcome Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 me Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 7 Rubbermaid i Polycom Practitioner Cart POWER UP With the system completely turned off press the Power button on the Control Keypad 3 N 9995 00909 900009 The keypad LCD will light up the controller will beep All devices integrated into the Practitioner Cart will automatically turn on and boot up If on off switch is pressed it will power off entire cart even in battery mode In combination with a low speed of movement continuous
30. y Cabinet Battery and PDU Compartment Secured Technology Cabinet with 4 Double Wheel Casters Front Polycom HDX 8000 Locking Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Rubbermaid 2 Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 Healthcare 4 Q Polycom RealPresence Practitioner Cart 8000 1080p 12x HD Camera Allows top quality video for codec and Room Systems alike Audio Sound Bar Sound bar has audio control on Omni Directional Microphone Has easy devi evice push mute capability with visual LED lights for mode LCD Control Keypad Controls the drawer lock work light lift system and monitors the onboard power system LCD Monitor Multi Purpose Bins Can be removed for emptying Secure AV Cabinet Key locked and or cleaning fan cooled AV compartment for codec and or PC Custom l O Data Plate Custom I O data plate for various inputs and Secure Drawers Accessed by keyless outputs into the codec entry system Drawers are fully removable Drawers automatically lock Battery and PDU Compartment 55 Ah sealed lead acid battery and power distribution unit Spiral Cord Always plug cart in when not in use or if power levels reach low levels Hang cord on rear handle when not in use Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Po

Download Pdf Manuals

image

Related Search

Related Contents

PDFファイル - 医薬品医療機器総合機構  要求水準書【PDF】  TZ 6156 - CT 4 6 - ET 4. 8 Computer 2012_EN-ES-IT  User Manual  Notice d`utilisation  Módulo Factura Electrónica Manual de usuario  Glass Capsule Standard Platinum Resistance  HP ProLiantサーバーGen8 導入事例集  Roberts Radio SRC985 User's Manual  MG-01U 取扱説明書ダウンロード(4.39MB  