Home

Planet Technology FGSW-2624SF User's Manual

image

Contents

1. Figure 2 2 FGSW 2624SF Switch front panel 2 1 3 LED Indications The front panel LEDs indicates instant status of port links data activity and system power helps monitor and troubleshoot when needed FGSW 2620VM LED indication B System LED Color Function PWR seen Lights to indicate that the Switch has power R Per 10 100Base TX RJ 45 port Color Function LNK ACT Green Lights to indicate the link through that port is successfully established 100 Green Lights to indicate the port is running in 100Mbps speed R Per 10 100 1000Base T port SFP interfaces Color Function Lit indicate that the port is operating at 1000Mbps LNK ACT 1000 Off indicate that the port is operating at 10Mbps or 100Mbps Blink indicate that the switch is actively sending or receiving data over that port Lit indicate that the port is operating at 100Mbps
2. PORT21 v PORTS Y PORT14 A PORT23 v Sep k Y PORT16 TRUNK e E PORT18 RS PORT11 lr ml PORT2D 1 Wi Save Het Figure 4 3 2 VLAN PortBase choose interface 7 If there are many groups that over the limit of one page you can click Next to view other VLAN groups 8 Use Del button to delete unwanted VLAN 9 Use Edit button to modify existing VLAN group If the trunk groups exist you can see it ex Trunk1 Trunk2 in select menu of ports and you can configure it is the member of the VLAN or not 4 3 1 1 2 802 1Q VLAN Tagged based VLAN is an IEEE 802 1Q specification standard Therefore it is possible to create a VLAN across devices from different switch venders IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frames Tag contains a VLAN Identifier VID that indicates the VLAN numbers You can create and delete Tag based VLAN There are 26 VLAN groups to provide configure Enable 802 1Q VLAN the all ports on the switch belong to default VLAN VID is 1 The default VLAN can t be deleting R Understand nomenclature of the Switch Tagging and Untagging Every port on an 802 1Q compliant switch can be configured as tagging or untagging Tagging Ports with tagging enabled will put the VID number priority and other VLAN information into the header
3. If 802 1X is not enabled or supported on the network access device any EAPOL frames from the client are dropped If the client does not receive an EAP request identity frame after three attempts A Notice to start authentication the client transmits frames as if the port is in the authorized state A port in the authorized state effectively means that the client has been successfully authenticated When the client supplies its identity the switch begins its role as the intermediary passing EAP frames between the client and the authentication server until authentication succeeds or fails If the authentication succeeds the switch port becomes authorized The specific exchange of EAP frames depends on the authentication method being used Figure 2 43 shows a message exchange initiated by the client using the One Time Password OTP authentication method with a RADIUS server 64 FGSW 2620VM FGSW 2624SF User s Manual Authentication server 802 1X Switch RADIUS O A e Ges EAPOL Start EAP Request Identity Client EAP Response ldentity RADIUS Access Request r p l gt EAP Request OTP RADIUS Access Challenge a EAP Response OTP RADIUS Access Request pa EAP Success RADIUS Access Accept Port Authorized EAPOL Logoff Port Unauthorized E Ports in Authorized and Unauthorized States The switch port state determines whether or not the client is granted access to the network The port start
4. FGSW ACL Configure screen 83 FGSW 2620VM FGSW 2624SF User s Manual Before the ACL Configure Notice It is important to set the VLAN mode to Port Based or 802 10 VLAN before you start the ACL configure Due to the ACL will check the VLAN ID if necessary the VLAN mode must be set to Port Based or 802 10 mode And once the VLAN mode is changed the system has to reboot to apply the new settings To set up the VLAN mode click the VLAN Configuration at the Function Menu tree The VLAN mode page appears as the following VLAN Configuration VLAN Operation Mode 80210 _ el VLAN Group IK 84 FGSW 2620VM FGSW 2624SF User s Manual Deny Policy Sample Case 1 Deny specific Source IP Address Host Purpose Verify positive and negative matches to a specific host IP address with a 32 bit mask no matter the rule defined as permit or deny Check for Class A B and C address 1 To set a Host as the target at this case 2 Once the deny policy be applied all IP packets from the target Host IP Address will be dropped 3 No matter IP packets form the target be transmitted to Internet or Intranet within the same IP segment they will be dropped Case Design Action Match Host IP Source IP Address 192 168 1 1 255 255 255 255 Destination IP Address ANY Device Connection and Configuration K Sec Router or L3 Switch ACL Switch
5. chosen to forward packets 3 Illustration of STP A simple illustration of three switches connected in a loop is depicted in following Figure In this example you can anticipate some major network problems if the STP assistance is not applied If switch A broadcasts a packet to switch B switch B will broadcast it to switch C and switch C will broadcast it to back to switch A and so on The broadcast packet will be passed indefinitely in a loop potentially causing a network failure In this example STP breaks the loop by blocking the connection between switch B and C The decision to block a particular connection is based on the STP Calculation of the most current Bridge and Port settings Now if switch A broadcasts a packet to switch C then switch C will drop the packet at port 2 and the broadcast will end there Setting up STP using values other than the defaults can be complex Therefore you are advised to keep the default factory settings and STP will automatically assign root bridges ports and block loop connections Influencing STP to choose a particular switch as the root bridge using the 52 FGSW 2620VM FGSW 2624SF User s Manual Priority setting or influencing STP to choose a particular port to block using the Port Priority and Port Cost settings is however relatively straight forward LAN lk Portcast 19 A Port 3 A 7 Bridge ID 15 E 3 3 Port 1 Port 2 A h J Portcast 4 Portca
6. Delaying Member Idle Member Timer Expried Send report IGMP State Transitions IGMP Snooping Configuration The default status of the IGMP Snooping function is disabled To turn on the IGMP Snooping select Enable of the IGMP Snooping Status field and click on the OK button to save 4 3 3 1 IGMP Configuration The switch support IP multicast you can enable IGMP protocol on web management s switch setting advanced page then display the IGMP snooping information in this page you can view difference multicast group VID and member port in here IP multicast addresses range from 224 0 0 0 through 239 255 255 255 The Internet Group Management Protocol IGMP is an internal protocol of the Internet Protocol IP suite IP manages multicast traffic by using switches routers and hosts that support IGMP Enabling IGMP allows the ports to detect IGMP queries and report packets and manage IP multicast traffic through the switch IGMP have three fundamental types of message as follows 57 FGSW 2620VM FGSW 2624SF User s Manual Message Description A message sent from the querier IGMP router or switch asking for a response from Query each host belonging to the multicast group A message sent by a host to the querier to indicate that the host wants to be or is a Report member of a given group indicated in the report message A message sent by a host to the querier to indicate that the host has quit to be
7. L4 Protocol tTcp parts Oupp parts ACL Policy Entry O 5 deny any 192 168 001 0011255 255 255 255 000 000 000 0001255 255 255 255 top 80 uncheck 92 FGSW 2620VM FGSW 2624SF User s Manual Case 5 Deny Specify Protocol SMTP Purpose 1 SMTP packets from specific Host IP Address will be dropped 2 Other packets from specific Host IP Address will be forwarded Case Design Action DENY Match Protocol Service Type SMTP Port 25 Source IP Address Host Destination IP Address ANY Device Connection and Configuration Se Router or L3 Switch ACL Switch Source Port SMTP Sn roto cola E TCP Port 25 93 FGSW 2620VM FGSW 2624SF User s Manual ACL Policy Configuration Group ID B 1 255 Action VLAN any OvVID 1 1 4094 Packet Type 4 4 O any 1p 192 168 1 1 STAR ANY Type 0x Mask 255 255 255 255 O Any O 1P 0 0 0 0 Mask 255 255 255 255 IP Fragment O Protocol L4 Protocol O TCP Porte 29 Cup Ports Src IP Address Dst IP Address ACL Policy Entry SrcIP Mask DstIP Mask L4 Protocol IP Fragment O 6 deny any 192 168 001 001 255 255 255 255 000 000 000 0001255 255 255 255 tcp 25 uncheck 94 Y PLANET Networking
8. Position Title Product Manager 4 L e Taiwan 22th Jan 2008 Place Date Legal Signature PLANET TECHNOLOGY CORPORATION e mail sales planet com tw http www planet com tw 11F No 96 Min Chuan Road Hsin Tien Taipei Taiwan R O C Tel 886 2 2219 9518 Fax 886 2 2219 9528 EC Declaration of Conformity For the following equipment Type of Product 24 Port 100Mbps SFP 2 Gigabit TP SFP Combo Web Smart Ethernet Switch Model Number FGSW 2624SF Produced by Manufacturers Name Planet Technology Corp Manufacturer s Address 11F No 96 Min Chuan Road Hsin Tien Taipei Taiwan R O C is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on 89 336 EEC For the evaluation regarding the EMC the following standards were applied Emission EN 50081 1 1992 Conducted Radiated EN 55022 1998 Harmonic EN 61000 3 2 1995 A1 A2 1998 14 2000 Flicker EN 61000 3 3 1995 Immunity EN 55024 1998 ESD EN 61000 4 2 RS EN 61000 4 3 EFT Burst EN 61000 4 4 Surge EN 61000 4 5 CS EN 61000 4 6 Voltage Disp EN 61000 4 11 Responsible for marking this declaration if the Manufacturer O Authorized representative established within the EU Authorized representative established within the EU if applicable Company Name Planet Technology Corp Company Address 11F No 96 Mi
9. 0x16 Membership Report version 2 0x17 Leave a Group version 2 0x12 Membership Report version 1 IGMP packets enable multicast routers to keep track of the membership of multicast groups on their respective sub networks The following outlines what is communicated between a multicast router and a multicast group member using IGMP A host sends an IGMP report to join a group A host will never send a report when it wants to leave a group for version 1 A host will send a leave report when it wants to leave a group for version 2 Multicast routers send IGMP queries to the all hosts group address 224 0 0 1 periodically to see whether any group 56 FGSW 2620VM FGSW 2624SF User s Manual members exist on their sub networks If there is no response from a particular group the router assumes that there are no group members on the network The Time to Live TTL field of query messages is set to 1 so that the queries will not be forwarded to other sub networks IGMP version 2 introduces some enhancements such as a method to elect a multicast queried for each LAN an explicit leave message and query messages that are specific to a given group The states a computer will go through to join or to leave a multicast group are shown below Non Member Leave Group Stop Timer Join Group Send Report Start Timer Leave Group P P 4 Guery Received Start Timer Report Received Stop Timer
10. Flows Control Set flow control function is ON or OFF in Full Duplex mode Apply button Press the button to apply all configurations When you select the port you can see port current configure shows in below 31 FGSW 2620VM FGSW 2624SF User s Manual Port Control Auto Negotiation Enable vw On v Auto Y On ei Flow Control Speed Duplex Auto Negotiation Speed Duplex Flow Control Port Type State Config PORTZ 100TK Enable On Auto Om Figure 4 2 2 Select the Port Control screenshot For the model FGSw 2624SF Port 1 to Port 24 is set to 100Full as default setting 32 4 2 2 Port Mirror FGSW 2620VM FGSW 2624SF User s Manual The Port mirroring is a method for monitor traffic in switched networks Traffic through ports can be monitored by one specific port That is traffic goes in or out monitored ports will be duplicated into mirror port Object Port Mirroring Mode Analysis Port Monitor Port Apply button Port Mirroring Port Mirroring Mode Analysis Port Monitored Port Figure 4 2 3 Prot Mirroring screenshot Description Set mirror mode Disable RX TX Its mean mirror port can be used to see all monitor port traffic You can connect mirror port to LAN analyzer or netxray The ports you want to monitor All monitor port traffic will be copied to mirror port You can select max 25 m
11. LNK ACT 100 Off indicate that the port is operating at 10Mbps or 1000Mbps Blink indicate that the switch is actively sending or receiving data over that port Lit indicate that the port is operating at full duplex mode Off indicate that the port is operating at half duplex mode 11 FGSW 2620VM FGSW 2624SF User s Manual FGSW 2624SF LED indication E System LED Color Function mun Green Lights to indicate that the Switch has power Hm Per 100Base FX SFP slot LED Color Function LNK ACT Green Lights to indicate the link through that port is successfully established R Per 10 100 1000Base T port SFP interfaces Color Function LED Lit indicate that the port is operating at 1000Mbps LNK ACT 1000 Off indicate that the port is operating at 10Mbps or 100Mbps msc om Blink indicate that the switch is actively sending or receiving data over that port Lit indicate that the port is operating at 100Mbps LNK ACT 100 Off indicate that the port is operating at 10Mbps or 1000Mbps DOEN Blink indicate that the switch is actively sending or receiving data over that port Lit indicate that the port is operating at full duplex mode o Off indicate that the port is operating at half duplex mode 1 Press the RESET button once The t Switch will reboot automatically Press the RESET button for about 10 seconds The Switch will back to the factory default mode the entire configuration will be
12. o Default Gateway 0 0 0 0 o The other setting value is back to disable or none 29 FGSW 2620VM FGSW 2624SF User s Manual 4 1 7 System Reboot BEE Reboot Reboot the Switch in software reset Click button to reboot the Switch Reboot System Please click Reboot button to restart switch device Figure 4 1 9 System Reboot screenshot 30 FGSW 2620VM FGSW 2624SF User s Manual 4 2 Port Configuration In Port page it has five parts of setting m Port control RB Port mirror Bandwidth control m Port statistics B Port trunk We will describe the configure detail in following 4 2 1 Port Control This section introduces detail settings of per port on Switch the screen in Figure 4 2 1 appears and following table descriptions the Port Configuration objects of the Switch Port Control Auto Negotiation Flow Speed Duplex Control Enable On e Auto ei onw Ges Auto NegotiationiSpeed Duplex Flow Control PortiType State Config Config Figure 4 2 1 Port Control screenshot Object Description pan Select the port by scroll the list in Port column State User can disable or enable this port control Auto Negotiation User can set auto negotiation mode is Auto N way specify the speed duplex on this port and enable auto negotiation Force of the port Speed Duplex Set the speed and full duplex or half duplex mode of the port
13. of all packets that flow into those ports If a packet has previously been tagged the port will not alter the packet 44 FGSW 2620VM FGSW 2624SF User s Manual thus keeping the VLAN information intact The VLAN information in the tag can then be used by other 802 1Q compliant devices on the network to make packet forwarding decisions o Untagging Ports with untagging enabled will strip the 802 1Q tag from all packets that flow into those ports If the packet doesn t have an 802 1Q VLAN tag the port will not alter the packet Thus all packets received by and forwarded by an untagging port will have no 802 1Q VLAN information Remember that the PVID is only used internally within the Switch Untagging is used to send packets from an 802 1Q compliant network device to a non compliant network device Frame Income Income Frame is tagged Income Frame is untagged Frame Leave Leave port is tagged Frame remains tagged Tag is inserted Leave port is untagged Tag is removed Frame remain untagged R VLAN Group Configuration VLAN Configuration LAN Operation Mode 02 10 v LAN Group 1 Figure 4 3 3 802 1Q VLAN interface 1 Click the hyperlink VLAN Configuration to enter the VLAN configuration interface 2 Select 802 1Q at the VLAN Operation Mode to enable the 802 1Q VLAN function Add 3 Click Ado to create a new VLAN group Then the VLAN Group column appears 4 Input a VLAN gro
14. 1 6 Trap Management screenshot Object Description IP Address Fill in the trap device IP Community Strings The trap device community strings Trap version The Trap version Add button Press the button to add the management SNMP community strings on the Switch Remove button Press the button to remove the management SNMP community strings on the Switch 28 FGSW 2620VM FGSW 2624SF User s Manual 4 1 5 TFTP Upgrade It provides the functions to allow a user to update the Switch firmware Before updating make sure you have your TFTP server ready and the firmware image is on the TFTP server Object TFTP TFTP Server IP Address 1192 168 0 66 ee ae Firmware File Name image bin Figure 4 1 7 TFTP Update Firmware screentshot Description TFTP Server IP Address Fill in your TFTP server IP Firmware File Name The name of firmware image Apply button Press the button for upgrade the Switch firmware 4 1 6 Factory Default Reset Switch to default configuration default value to as following configuration Click Default button to reset Switch to default setting Factory Default Please click Default button to restore factory default setting Figure 4 1 8 Factory Default screenshot After the Default buttomn be pressed and reboot the system will load the default IP settings as following o Default IP address 192 168 0 100 o Subnet mask 255 255 255 0
15. Ethernet connection please make sure the manager PC must be set on the same IP subnet address For example the default IP address of the FGSW Managed Switch is 192 168 0 100 then the manager PC should be set at 192 168 0 x where x is a number between 1 and 254 except 100 and the default subnet mask is 255 255 255 0 IP Address 192 168 0 100 Subnet Mask 255 255 255 0 FGSW Managed Switch PC Workstation with Web Browser IP Address PES 192 168 0 100 IP Address 192 168 0 x Figure 3 1 IP Management diagram 3 4 System Login 1 Use Internet Explorer 6 0 or above Web browser enter IP address http 192 168 0 100 the factory default IP address or that you have just changed in console to access the Web interface 2 When the following dialog box appears please enter the default user name admin and password admin or the username password you have changed via console The login screen in Figure 3 2 appears Default User name admin Default Password admin 20 FGSW 2620VM FGSW 2624SF User s Manual Connect to 192 168 0 100 The server 192 168 0 100 at Web Management requires a username and password Warning This server is requesting that your username and password be sent in an insecure manner basic authentication without a secure connection User name Es dhin Password sees el C Remember my password Figure 3 2 Login screen 3 Click Enter
16. Packet Collision PORT 100TXDownEnable O0 0 OF 0 0 PORT2 100TXDownEnable O PORTS 1001 Down Enable O PORT4 100TX Down Enable 0 PORTS 100TX Down Enable 0 PORT6 100TXDownEnable O PORT 100TXDowneEnable O ooooo n ojolojojoja olololojojo PORTS 100TXDownEnable 0 PORT10 100TXDownEnable 0 PORT11100TX DownEnable 0 PORT12 100TxX Down Enable O PORT13 100TX Down Enable O PORTI14 100TX Down Enable 0 PORT15 100Tx Down Enable 0 olojojojojo ojololojolo ojojojojojojo a o PORT17 100TX Down Enable 0 0 PORT18100TXDownEnable O0 0 PORT19100TXDownEnable O 0 PORT20 100TXDownEnable O 0 PORT21 100TX DownEnable 0 D Figure 4 2 5 Port Statistics screenshot Object Description pen Indicate port 1 to port 26 Display the Speed duplex mode of each port on the Switch Link The state of the link indicating a valid link partner device Up means a device is successful connected to the port Down means no device is connected Ste ina on Disable or Enable sto son nes 35 FGSW 2620VM FGSW 2624SF User s Manual 4 2 5 Port Trunk The Link Aggregation Control Protocol LACP provides a standardized means for exchanging information between Partner Systems on a link to allow their Link Aggregation Control instances to reach agreement on the identity of the Link Aggregation Group to which the link belongs move the link to that Link Aggregation Group and enable its transmission and reception fu
17. Part No 2080 A92350 002 FGSW 2620VM FGSW 2624SF User s Manual Table of Contents 1 INTRODUCTION BEE 6 ER Ge E CONTENTS add 6 12 HOWTO H SE THIS MANUAL i 6 1 3 PRODUCT FEATURE EE 7 1 4 PRODUCT SPEGIFICATION EE 8 2 INSTALEATI N csi iii 10 211 PRODUCT DESCRIPTION td tad ao ias 10 2 Pal Product e VIEW ici A E 10 2 25 Witch FrontiPanel cio icon ol ia st do EE e 11 PS LED NICO Sir a ds 11 2 1 4 Switch Rear A 13 2 2 INSTALL THE SWITCH iia a AAA AA A A as 14 2 271 Desktop l lea TTT 14 22 2 Rack Mountings A A A iia 14 2 2 3 Installing the SFP EE 16 3 SWITCH MANAGEMENT ssss sss s seene nenen enen nenen enen nenen 19 3 1 ABOUT WEB BASED MANAGEMENT 19 3 2 REQUIREMENTS eu md ere 19 3 3 PREPARING FOR WEB MANAGEMENT xe nn nn nn rra an KK aana nn ana n EEan nenna nne 20 STEE IN TT hee EE dE A 20 30 ONLINE HELP cada A AAA A A AAA io Aaen 22 3 60 VIEW THE PORT INFORMA TON aida 22 4 WEB BASED MANAGEMENT csssccsssscccsseccsseecsseeesseeeneseeenaseeeneeeensseensseseneeesenas 23 A SYSTEM aia 23 4 1 1 SystemintormaliON as a than te ha eee ee ee epee eee tte ee ee ee E S 23 AVA Bas Ciutat tal in dto dde iii did dia tte 23 AL o A EE EEN 24 4 1 2 1P Configurar A ie ied 25 A ASS ACCOUNT Pass WO oso il o aa 26 4 1 4 SNMP Management o TT 27 ENS le TTT 27 K NE Trap Configuration T 28 415 METP Upgrade asa sasana aas aaa gan a a ai 29 FGSW 2620VM FGSW 2624SF User s Manual 41 60 Factory Default ovio lt E 29 En De e
18. Traffic is filtered based on the destination addresses To filter the MAC Address click on the Security MAC Filtering menu button the main web page then shows the MAC Filter function table 1 Eil the MAC Address field with MAC address in the format XX XX XX XX XX XX 2 Input the VLAN ID 3 Click on the Add button to add 4 To remove the MAC Address filtered by the port Simply click on the Delete button of the MAC Address in the Current Filtering MAC Table MAC Filter Figure 4 5 6 MAC Filtering interface 76 FGSW 2620VM FGSW 2624SF User s Manual Object Description MAC Address Enter the MAC address that wants to filter VLAN ID If tag based 802 10 VLAN are set up on the switch in the VLAN ID box type the VID to associate with the MAC address Add oo Press this button for add MAC filtering on the Switch Delete Press this button for delete MAC filtering on theSwitch 4 5 5 IP Secuity IP security function allows user to assign 5 specific IP addresses that have permission to access the switch through the web browser for the securing switch management IP Security IP Security Mode Disable v Security IP 1 WR Security ti Ir Security IP3 JUM Security IP 4 WEB Kieffer Figure 4 5 7 IP Security screen C Description IP Security Mode When this option is in Enable mode the Enable HTTP Server and Enable Telnet Se
19. a switch or an entire department On port based VLAN NIC do not need to be able to identify 802 1Q tags in packet headers NIC send and receive normal Ethernet packets If the packet s destination lies on the same segment communications take place using normal Ethernet protocols Even though this is always the case when the destination for a packet lies on another switch port VLAN considerations come into play to decide if the packet is dropped by the Switch or delivered IEEE 802 1Q VLANs IEEE 802 1Q tagged VLAN are implemented on the Switch 802 1Q VLAN require tagging which enables them to span the entire network assuming all switches on the network are IEEE 802 1Q compliant VLAN allow a network to be segmented in order to reduce the size of broadcast domains All packets entering a VLAN will only be forwarded to the stations over IEEE 802 1Q enabled switches that are members of that VLAN and this includes broadcast multicast and unicast packets from unknown sources VLAN can also provide a level of security to your network IEEE 802 1Q VLAN will only deliver packets between stations that are members of the VLAN Any port can be configured as either tagging or untagging The untagging feature of IEEE 802 1Q VLAN allows VLAN to work with legacy switches that don t recognize VLAN tags in packet headers The tagging feature allows VLAN to span multiple 802 1Q compliant switches through a single physical connection and allows Sp
20. assigned to a default VLAN with a PVID equal to 1 Untagged packets are assigned the PVID of the port on which they were received Forwarding decisions are based upon this PVID in so far as VLAN are concerned Tagged packets are forwarded according to the VID contained within the tag Tagged packets are also assigned a PVID but the PVID is not used to make packet forwarding decisions the VID is Tag aware switches must keep a table to relate PVID within the switch to VID on the network The switch will compare the VID of a packet to be transmitted to the VID of the port that is to transmit the packet If the two VID are different the switch will drop the packet Because of the existence of the PVID for untagged packets and the VID for tagged packets tag aware and tag unaware network devices can coexist on the same network A switch port can have only one PVID but can have as many VID as the switch has memory in its VLAN table to store them Because some devices on a network may be tag unaware a decision must be made at each port on a tag aware device before packets are transmitted should the packet to be transmitted have a tag or not If the transmitting port is connected to a tag unaware device the packet should be untagged If the transmitting port is connected to a tag aware device the packet should be tagged Default VLANs The Switch initially configures one VLAN VID 1 called default The factory default setting assigns al
21. erased The 2 Gigabit TP SFP combo ports are shared with port 25 26 of FGSW 2620VM Either of them can operate at the same time 12 FGSW 2620VM FGSW 2624SF User s Manual 2 1 4 Switch Rear Panel The rear panel of the Managed Switch indicates an AC inlet power socket which accepts input power from 100 to 240V AC 50 60Hz Figure 2 3 and Figure 2 4 shows the rear panel of the Switch FGSW 2620VM Rear Panel 100 240V AC 50 60Hz Figure 2 3 FGSW 2620VM Switch rear panel FGSW 2624SF Rear Panel 100 240V AC POWER 50 60Hz Figure 2 4 FGSW 2624SF Switch rear panel Power Notice 1 The device is a power required device it means it will not work till it is powered If your networks should active all the time please consider using UPS Uninterrupted Power Supply for your device lt will prevent you from network data loss or network downtime 2 In some area installing a surge suppression device may also help to protect your Switch from being damaged by unregulated surge or current to the Switch or the power adapter 13 FGSW 2620VM FGSW 2624SF User s Manual 2 2 Install the Switch This section describes how to install the Managed Switch and make connections to it Please read the following topics and perform the procedures in the order being presented 2 2 1 Desktop Installation To install the Managed Switch on desktop or shelf please follows these steps S
22. need to inform nearby routers that they will become members of a multicast group The Internet Group Management Protocol IGMP is used to communicate this information IGMP is also used to periodically check the multicast group for members that are no longer active In the case where there is more than one multicast router on a sub network one router is elected as the queried This router then keeps track of the membership of the multicast groups that have active members The information received from IGMP is then used to determine if multicast packets should be forwarded to a given sub network or not The router can check using IGMP to see if there is at least one member of a multicast group on a given subnet work If there are no members on a sub network packets will not be forwarded to that sub network IGMP Versions 1 and 2 Multicast groups allow members to join or leave at any time IGMP provides the method for members and multicast routers to communicate when joining or leaving a multicast group IGMP version 1 is defined in RFC 1112 It has a fixed packet size and no optional data The format of an IGMP packet is shown below IGMP Message Format Octets 0 8 16 31 Type Response Time Checksum Group Address all zeros if this is a query The IGMP Type codes are shown below Type Meaning 0x11 Membership Query if Group Address is 0 0 0 0 0x11 Specific Group Membership Query if Group Address is Present
23. sities cl bade die a Aa ds 30 4 2 PORT CONFIGURATION 082 dee ias 31 4 2 1 POCO a CASEL 31 4 2 2 POr Mitra A AA a 33 4 2 3 Bandwidth Control ss saa aas lat tota teta disc a aes 34 A ln Statistics E 35 4 2 5 Port UNK atn eerste dene ea EE EE Ln ee 36 4 2 5 1 Aggregator set copii aid 36 e ele Ee lu te vu Ee a i a cb ci nala ap a 37 Ke lee EN tee WT 38 4 3 SWITCHING tia 39 ASA VLAN ies A tna Movie declan atest bis eet aes 39 4 32 WEAN Configuration ciao 42 4 3 1 2 802 1Q Ihgress EE 47 4 3 2 Rapid Spaning Trees ii stile bhatt ge eis nl hdl eek AE ee ea eel ad 48 But Uer 54 4322 Per Port CONQUE O TT 55 4 3 3 IG MP SNOOP Ng uti AA AA E a eee ted eee 56 43 4 Forwarding MEET 59 AEA QOS acia 60 44 1 QoS Configuration ici teins aie A ellie da iit 60 4 5 SECURITY EE 62 4 5 1 802 1x Radius secs ei bi Wied A Ae ee iste ee eet 63 4 5 1 1 System Configuration sic iste Me ee ee ce eh EE 66 4 5 1 2 Perport Ee ue Teen EE 68 4 5 1 3 802 1X Client Configuration TTT 70 4 5 1 4 Mise Contig uration viii E doi Na NG saa Pah 73 4 5 2 Access Control Mistica arar T 74 4 5 3 Mee e Kl 75 ASA MAG Ella eo arde oo 76 455 PSU is AAA A ee 77 5 SWITCH OPERATION aaa aaiae NISSAN SNNN 78 51 ADDRESS TABLE ETH 78 STO a a EIN TINTE ES A A c A E VE ae EN ce 78 5 3 FORWARDING amp FILTERING sese e e e e e e eee 78 5 4 STORE AND FORWARD isa sajane daka na sababe tii 78 FGSW 2620VM FGSW 2624SF User s Manual 5 5 AUTO NEGOTIATION TEE 79 6 TROUBLESHOOTIN
24. t be deleting 46 FGSW 2620VM FGSW 2624SF User s Manual 4 3 1 2 802 10 Ingress Filter This section provides 802 1Q Ingress Filter of each port from the Switch the screen in Figure 4 3 5 appears 802 1Q Ingress Filter A E TT mz PORT3 Disable lt ai v i PORT4 Disable v All v PORTS Disable gt a y E PORT Disable lt a ei 1 PORTS Disable lt ar porro Taare S us K PORTIO Disable ze alle Eo PORT11 Disable v AN w 1 PORT12 Disable v al 1 ens Diane S A K PORT14 Disable lt ai WE H PORTIS Disable lt a ei H PORTIG Disable lt All v 1 Figure 4 3 5 802 10 Ingress filter interface 47 FGSW 2620VM FGSW 2624SF User s Manual Description Ingress Filter Ingress filtering lets frames belonging to a specific VLAN to be forwarded if the port belongs to that VLAN Enable Forward only packets with VID matching this port s configured VID Disable Disable Ingress filter function ALL Acceptable all Packet Tag Only Only packet with match VLAN ID can be permission to go through the port Set the port VLAN ID that will be assigned to untagged traffic on a given port This feature is useful for accommodating devices that you want to participate in the VLAN but that don t support tagging The switch each port allows user to set one VLAN ID the range is 1 255 default VLAN ID is 1 The VLAN ID must as same as the VLAN ID that the port belong to VLAN group or th
25. tags from packets This priority tag determines the packet s degree of expeditiousness and determines the queue to which it will be assigned Priority tags are given values from 0 to 7 with O being assigned to the lowest priority data and 7 assigned to the highest The highest priority tag 7 is generally only used for data associated with video or audio applications which are sensitive to even slight delays or for data from specified end users whose data transmissions warrant special consideration The Switch allows you to further tailor how priority tagged data packets are handled on your network Using queues to manage priority tagged data allows you to specify its relative priority to suit the needs of your network There may be circumstances where it would be advantageous to group two or more differently tagged packets into the same queue Generally however it is recommended that the highest priority queue Queue 1 be reserved for data packets with a priority value of 7 Packets that have not been given any priority value are placed in Queue 0 and thus given the lowest priority for delivery A weighted round robin system is employed on the Switch to determine the rate at which the queues are emptied of packets The ratio used for clearing the queues is 4 1 This means that the highest priority queue Queue 1 will clear 4 packets for every 1 packet cleared from Queue 0 Remember the priority queue settings on the Switch are for all por
26. the specified port is required to be held in the Authorized state Authorized the specified port is set to the Authorized or Unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server Disable The specified port is required to be held in the Authorized state Apply Button Press this button to save the value on the Switch Set the Ports Authenticate Status to Authorized if the port is connected to the RADIUS server or A Notice the port is a uplink port that is connected to another switch Or once the 802 1X stat to work the switch might not be able to access the RADIUS server 68 FGSW 2620VM FGSW 2624SF User s Manual 5 Create user data That step is different of Local Authenticate the establishment of the user data needs to be created on the Radius Server PC For example the Radius Server founded on Win2000 Server and then Y Documents E Active Directory Domains and Trusts G Active Directory Sites and Services amp active Directory Users and Computers K Component Services E Computer Management ak Configure Your Server GE T Data Sources ODBC i ss Distributed File System 5 Domain Controller Security Policy My Network Pl Routing and Remote Access Sy Services 4 pl Telnet Server Administration Programs erver y Settings Advanced Windows 2 6 Enter Active Dire
27. 02 1p CoS on each port Port Based priority Display detail traffic counters on each port Rate Limit Inbound Rate Limit and Outbound Traffic shaping allow per 1Mbits setting Access Control List Supports up to 16 Access Control list groups Standards Conformance IEEE 802 3 Ethernet IEEE 802 3u Fast Ethernet IEEE 802 3ab Gigabit Ethernet IEEE 802 3z Gigabit Ethernet Standards Compliance IEEE 802 3x Full duplex flow control IEEE 802 1Q Tag Based VLAN IEEE 802 1p Class of service IEEE 802 1X Port Based Authentication IEEE 802 1w Rapid Spanning Tree protocol The specification of FGSW 2624SF is for hardware version 2 only FGSW 2620VM FGSW 2624SF User s Manual 2 INSTALLATION This section describes the functionalities of the FGSW Managed Switch s components and guides how to install it on the desktop or shelf Basic knowledge of networking is assumed Please read this chapter completely before continuing 2 1 Product Description The PLANET FGSW Managed Switch offers 24 10 100Mbps Fast Ethernet ports or 24 100Base FX SFP slots with 2 Gigabit TP SFP combo ports Port 25 26 The two Gigabit TP SFP combo ports can be either 1000Base T for 10 100 1000Mbps or 1000Base SX LX through SFP Small Factor Pluggable interface It boasts a high performance switch architecture that is capable of providing non blocking switch fabric and wire speed throughput as high as 8 8Gbps Its two built in GbE uplink ports also offer incredible extensibil
28. 240 200000 priority must be a multiple of 16 RSTP Port Status Path Port Oper Oper Stp Cost Priority P2P Edge Neighbor Port State Role Figure 4 3 7 SPT Per Port Configuration interface Description The cost of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through 200000000 Decide which port should be blocked by priority in LAN Enter a number 0 through 240 in steps of 16 Some of the rapid state transactions that are possible within RSTP are dependent upon whether the Port concerned can only be connected to exactly one other Bridge ie it is served by a point to point LAN segment or can be connected to two or more Bridges i e it is served by a shared medium LAN segment The adminPointToPointMAC allow the p2p status of the link to be manipulated adminitratively Present in implementations that support the identification of edge ports All ports directly connected to end stations cannot create bridging loops in the network and can thus directly transition to forwarding skipping the listening and learning stages Admin Non Stp If true this port will not participate in RSTP Apply button Press the button to save the modification 55 FGSW 2620VM FGSW 2624SF User s Manual 4 3 3 IGMP Snooping About the Internet Group Management Protocol IGMP Snooping Computers and network devices that want to receive multicast transmissions
29. 255 255 MT e Protocol L4 Protocol OtTcp Port Cup parts Ether Type m ml Type 0x Dst IP Address 90 FGSW 2620VM FGSW 2624SF User s Manual Case 4 Deny Specify Protocol HTTP WWW Purpose Verify positive and negative matches to network IP address with a specific protocol or TCP UDP Port number no matter the rule defined as permit or deny 1 Packets with Layer 4 protocol match the specific ACL protocol will be dropped 2 Packets with Layer 4 protocol not match the specific ACL protocol will be forwarded Case Design Action DENY Match Protocol Service Type HTTP WWW Port 80 Source IP Address Host Destination IP Address ANY Device Connection and Configuration a Ss ro cd HTTP Port 80 Router or L3 Switch f R E wen iren E ACL Switch E 1g Google 91 FGSW 2620VM FGSW 2624SF User s Manual 192 168 1 1 HTTP Host 5 ANY 255 255 255 255 Port 80 ACL Policy Configuration lae Group ID 5 1 255 Action Deny ei VLAN any Ovip 1 1 4094 Oany Gm 192 168 1 1 Mask 255 255 255 255 Src IP Address x Type 0x Ether Type Any H O Any O p 0 0 0 0 Dst IP Address Mask 255 255 255 255 IP Fragment Uncheck x O Protocol
30. 85 FGSW 2620VM FGSW 2624SF User s Manual Host 1 192 168 1 1 Any Any ACL Policy Configuration ME lt gt RSC Oany Cup 7 Daa TA wna 192 168 1 1 ANY lv Type Ox Src IP Address Dst IP Address k 255 255 255 255 Mas thes Protocol L4 Protocol Otep Any w ports O UDP Any e Porte ACL Policy Entry vip SrcIP Mask DstIP Mask L4 Protocol IP Fragment deny any 192 168 001 001 255 255 255 255 000 000 000 0001255 255 255 255 any uncheck o 3 86 FGSW 2620VM FGSW 2624SF User s Manual Case 2 Deny specific Source IP Address Class C Purpose Verify a positive and negative matches to network IP address with a Class C 24 bit mask no matter the rule defined as permit or deny 1 Set Hosts within the same Class C Network domain as the targets at this case 2 Once the deny policy be applied all IP packets from the targets IP Addresses will be dropped 3 No matter IP packets form the targets be transmitted to Internet or Intranet within the same IP segment they will be dropped Case Design Action Match Class C 192 168 1 0 255 255 255 0 Source IP Address Destination IP Address ANY Device Connection and Configuration Router or L3 Switch ACL Switch ENN 87 FGSW 2620VM FGSW 2624SF
31. FGSW 26204M 24 Port 10 100Mbps with 2G TP SFP Combo Managed Ethernet Switch FGSW 2624SF de 24 100Base FX SFP Slots with 2G TP SFP Combo Managed Ethernet Switch M PLANET Networking amp Communication FGSW 2620VM FGSW 2624SF User s Manual Trademarks Copyright O PLANET Technology Corp 2008 Contents subject to which revision without prior notice PLANET is a registered trademark of PLANET Technology Corp All other trademarks belong to their respective owners Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications and makes no warranty and representation either implied or expressed with respect to the quality performance merchantability or fitness for a particular purpose PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manua
32. G rrara a aaa aa KEN aaa aaa aa eA aia aa SCENE aa gawaa aeng 80 GLIN ORRECTGONNEGTIONS sesa aranana E A A T E E a a agan E 80 6 2 DIAGNOSING LED INDICATORS seprai anara neb ian gan e ab aab i ka inea A ep aaa aga t pap aga Ea ga a KE ne a wek a a aaa aa TR aaa 80 APPENDIX A CABLE PIN ASSIGNMENT sss 81 FAW GABE nak saa naa a E e de ee de Me A e a a 81 7 2 100BASE TX 10BASE T PIN ASSIGNMENTS se eee e 81 7 3 RJ 45 CABLE PIN ASSIGNMENT ccccccccccececececececececececececeenceecesesecesesesacesesecacacecacecacececececececesecauanananananans 82 APPENDIX B ACCESS CONTROL LIST APPLICATION GUIDE sese e 83 Before the ACL Configure uc ties Assen mires ill dd rae 84 Case 1 Deny specific Source IP Address Host 85 Case 2 Deny specific Source IP Address Class C A 87 Case 3 Deny specific VLAN pockeis AAA 89 Case 4 Deny Specify Protocol HTTP AWWW AAA 91 Less o Dany aaa ro 1 RE 93 FGSW 2620VM FGSW 2624SF User s Manual 1 INTRODUCTION 1 1 Packet Contents Check the contents of your package for following parts L Fast Ethernet Managed Switch x1 L CD ROM user s manual x1 R Quick installation guide x1 L 19 rack mounting kit x1 L Power cord x1 L Rubber feet x 4 If any of these are missing or damaged please contact your dealer immediately if possible retain the carton including the original packing material and use them against to repack the product in case there is a need to return it to us for repair 1 2 How to
33. The following section will base on the Web screens of FGSW 2620VM for FGSW 2624SF the display will be the same to FGSW 2620VM 3 1 About Web based Management Inside the CPU board of the Managed Switch exist an embedded HTML web site residing in flash memory lt offers advanced management features and allow users to manage the Managed Switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer The Web Based Management supports Internet Explorer 6 0 It is based on Java Applets with an aim to reduce network bandwidth consumption enhance access speed and present an easy viewing screen 3 2 Requirements L Workstations of subscribers running Windows 98 ME NT4 0 2000 XP MAC OSS9 or later Linux UNIX or other platform compatible with TCP IP protocols a Workstation installed with Ethernet NIC Network Interface Card a Ethernet Port connect e Network cables Use standard network UTP cables with RJ45 connectors a Above Workstation installed with WEB Browser and JAVA runtime environment Plug in By default IE6 0 or later version does not allow Java Applets to open sockets The user has to explicitly modify the browser setting to enable Java Applets to use network ports 19 FGSW 2620VM FGSW 2624SF User s Manual 3 3 Preparing for Web Management The following shows how to start up the Web Management of the Managed Switch Note the FGSW Managed Switch is configured through an
34. Use This Manual This User Manual is structured as follows Chapter 2 Installation The chapter explains the functions of the Switch and how to physically install the Switch Chapter 3 SWITCH MANAGEMENT The chapter explains how to manage the Switch Chapter 4 WEB BASED MANAGEMENT The chapter explains how to manage the Switch by Web interface Chapter 5 Switch Operation The chapter explains how the Switch with Layer 2 operation does Chapter 6 TROUBLE SHOOTING The chapter explains how to trouble shooting of the Switch APPENDIX CABLE PIN ASSIGNMENT The chapter contains cable information of the Switch In the following section terms Managed Switch with upper case denote the FGSW 2620VM FGSW 2624SF Ethernet Switch Terms with lower case switch means any Ethernet switches FGSW 2620VM FGSW 2624SF User s Manual 1 3 Product Feature gt Physical Ports FGSW 2620VM 24 Port 10 100Mbps Fast Ethernet ports 2 10 100 1000Mbps TP and SFP shared combo interfaces Reset button for system management FGSW 2624SF 24 Port 100Base FX SFP Fast Ethernet slots 2 10 100 1000Mbps TP and SFP shared combo interfaces Reset button for system management Layer 2 Features Complies with the IEEE 802 3 IEEE 802 3u IEEE 802 3z and IEEE 802 3ab Gigabit Ethernet standard Each Switching ports support auto negotiation 10 20 100 200Mbps supported Auto MDI MDI X detection on each RJ 45 port Prevents packet loss with back pres
35. User s Manual Class C 2 192 168 1 0 255 255 255 0 Any Any ACL Policy Configuration van om Ov 1 1 4094 _ Packet Type ma ES SE Oany p 192 168 1 0 Ether Type Any x Type ox 2 1 255 Src IP Address Mask 255 255 255 0 any Op 0 0 0 0 Mask 255 255 255 255 Protocol L4 Protocol OTCP parts Cup porte Det IP Address ACL Policy Entry 2 deny lany 192 168 001 0001255 255 255 000 000 000 000 000 255 255 255 255 any uncheck 88 FGSW 2620VM FGSW 2624SF User s Manual Case 3 Deny specific VLAN packets Purpose Verify a positive and negative matches to network IP address with a specific VLAN ID no matter the rule defined as permit or deny 1 Packets with VLAN ID specific ACL VLAN ID will be dropped 2 Packets with VLAN ID not match the specific ACL VLAN ID will be forwarded Case Design Action Match Source IP Address Destination IP Address Device Connection and Configuration SES WAN Router or e a L3 Switch ki ACL Switch NN 533 535 VLAN 1 VLAN 2 89 FGSW 2620VM FGSW 2624SF User s Manual ACL Policy Configuration en gt VLAN Oany vip 2 14094 S Packet Type O Any O 1P 0 0 0 0 Src IP Address Mask 255 255 255 255 any O1P 0 0 0 0 Mask 255 255
36. a Leave Group member of a specific multicast group When you enable the IGMP Snooping you will see the relate information show as following figure IGMP Configuration IP Address LAN ID _Member Port 239 255 255 250 1 DA IGMP Protocol Enable v IGMP Query Enable v Figure 4 3 8 IGMP Snooping interface Object Description IP Address Show the IP Address for IGMP VLAN ID Show the VLAN ID for IGMP Member Port Show the Member Port for IGMP IGMP Protocol Enable or disable IGMP Protocol IGMP Query Enable or disable IGMP Query 58 FGSW 2620VM FGSW 2624SF User s Manual 4 3 4 Forwarding Table You can configure forwarding table of every port the screen in Figure 4 3 9 Forwarding Table Clear MAC Table Figure 4 3 9 Forwarding Table screen Object Description PotNo Indicate port 1 to port 26 Current MAC Address Listthe source MAC addresses those be learned on the specify port 59 FGSW 2620VM FGSW 2624SF User s Manual 4 4 QoS Quality of Service QoS is an advanced traffic prioritization feature that allows you to establish control over network traffic QoS enables you to assign various grades of network service to different types of traffic such as multi media video protocol specific time critical and file backup traffic QoS reduces bandwidth limitations delay loss and jitter lt also provides increased reliability for deliv
37. amp Communication EC Declaration of Conformi For the following equipment Type of Product 24 Port 10 100 2 Gigabit TP SFP Combo Layer 2 Managed Ethernet Switch Model Number FGSW 2620VM Produced by Manufacturers Name Planet Technology Corp Manufacturer s Address 11F No 96 Min Chuan Road Hsin Tien Taipei Taiwan R O C is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility 89 336 EEC 92 3 1 EEC 93 68 EEC For the evaluation regarding the Electromagnetic Compatibility the following standards were applied Emission EN 55022 1994 A1 1995 A2 1997 Class A Harmonic EN 61000 3 2 2000 Class A Flicker EN 61000 3 3 1995 A1 2001 Immunity EN 55024 1998 A1 2001 A2 2003 ESD EN 61000 4 2 2001 RS EN 61000 4 3 2002 A1 2002 EFT Burst EN 61000 4 4 1995 A1 2000 A2 2001 Surge EN 61000 4 5 2001 CS EN 61000 4 6 2001 Magnetic Field EN 61000 4 8 2001 Voltage Disp EN 61000 4 11 2001 Responsible for marking this declaration if the Manufacturer O Authorized representative established within the EU Authorized representative established within the EU if applicable Company Name Planet Technology Corp Company Address 11F No 96 Min Chuan Road Hsin Tien Taipei Taiwan R O C Person responsible for making this declaration Name Surname Kent Kang
38. an easy to use platform independent management and configuration facility It supports standard Simple Network Management Protocol SNMP and can be managed via any standard based management software 10 FGSW 2620VM FGSW 2624SF User s Manual 2 1 2 Switch Front Panel The unit front panel provides a simple interface monitoring the Switch Figure 2 1 to 2 2 shows the front panel of the Managed Switches FGSW 2620VM Front Panel 7 T gt VC gt Gs SR T SR mE T K SR T K CC 24 Port 10 100Mbps 2 Gigabit Managed Ethernet Switch 25 26 e 1000 wo mo E y A a pa ca pla ca pa calla ca ca ca ol ro 03 Im oso It 15 o FGSW 2620VM Pw Figure 2 1 FGSW 2620VM front panel FGSW 2624SF Front Panel 24 Port 100Base SFP 2 Gigabit Web Smart Switch IO L umm mm mu o z z c asar wad Kn wem ER NKA A se at ln bn I wo 100 0 FGSW 26245F oe ES DV ur IN 1 3 5 7 g T 13 15 17 19 EI 23
39. anning Tree to be enabled on all ports and work normally Any port can be configured as either tagging or untagging The untagging feature of IEEE 802 1Q VLAN allow VLAN to work with legacy switches that don t recognize VLAN tags in packet headers The tagging feature allows VLAN to span multiple 802 1Q compliant switches through a single physical connection and allows Spanning Tree to be enabled on all ports and work normally 40 FGSW 2620VM FGSW 2624SF User s Manual Some relevant terms Tagging The act of putting 802 1Q VLAN information into the header of a packet Untagging The act of stripping 802 1Q VLAN information out of the packet header 802 1Q VLAN Tags The figure below shows the 802 1Q VLAN tag There are four additional octets inserted after the source MAC address Their presence is indicated by a value of 0x8100 in the Ether Type field When a packet s Ether Type field is equal to 0x8100 the packet carries the IEEE 802 1Q 802 1p tag The tag is contained in the following two octets and consists of 3 bits of user priority 1 bit of Canonical Format Identifier CFI used for encapsulating Token Ring packets so they can be carried across Ethernet backbones and 12 bits of VLAN ID VID The 3 bits of user priority are used by 802 1p The VID is the VLAN identifier and is used by the 802 1Q standard Because the VID is 12 bits long 4094 unique VLAN can be identified The tag is inserted into the packet header making the ent
40. ctory Users and Computers create legal user data the next right click a user what you created to enter properties and what to be noticed 69 FGSW 2620VM FGSW 2624SF User s Manual gt TsInternetUser Properties 2h x Lei Console MemberOf Diin Envaorment Sessions Action Yer Remote control Terminal Services Profile General Address Account Profile Telephones Organization Tree User logon nai Active Direct E y wireless Test Planet comtw C Buiki Use logon name pre Windows 2000 sa MA TeirternetUser Fore Y User Logon Hours Log On To E Accounts locked cat e Ka Accour options IV User cannot change password IV Password never expires Store password using reversible encryption sl Account expres Ze Never End of Wednesday Jul 05 2006 7 The last run your 802 1X Client 4 5 1 3 802 1X Client Configuration Windows XP is originally 802 1X support As to other operating systems windows 98SE ME 2000 an 802 1X client utility is needed The following procedures show how to configure 802 1X Authentication in Windows XP Please note that if you want to change the 802 1x authentication type of a wireless client Le switch to EAP TLS from EAP MD5 you must remove the current existing wireless network from your preferred connection first and add it in again e Configure Sample EAP MD5 Authentication 1 Go to Sta
41. dd a static MAC address it remains in the switch s address table regardless of whether the device is physically connected to the switch This saves the switch from having to re learn a device s MAC address when the disconnected or powered off device is active on the network again To bind the MAC Address click on the Security Static MAC Address menu button the main web page then shows the Static MAC Address function table 1 Eil the MAC Address field with MAC address in the format XX XX XX XX XX XX 2 Choose the port to bind the MAC Address in the Port field 3 Click on the Add button 4 Toremove the MAC Address binded by the port Simply click on the Delete button of the MAC Address in the MAC Address Table Static MAC Address A Figure 4 5 5 Static MAC Address interface 75 FGSW 2620VM FGSW 2624SF User s Manual Object Description MAC Address Enter the MAC address to and from which the port should permanently forward traffic regardless of the device network activity Port Select a port number If tag based IEEE 802 1Q VLANs are set up on the switch static addresses are associated with individual VLANs Type the VID tag based VLANs to associate with the MAC address Add Press this button for add Static MAC Address on the Switch Press this button for delete Static MAC Address on theSwitch 4 5 4 MAC Filter MAC address filtering allows the switch to drop unwanted traffic
42. destination address is on the same segment as the source address This confines network traffic to its respective domain reducing the overall load on the network The Switch performs Store and forward therefore no error packets occur More reliably it reduces the re transmission rate No packet loss will occur 5 5 Auto Negotiation The STP ports on the Switch have built in Auto negotiation This technology automatically sets the best possible bandwidth when a connection is established with another network device usually at Power On or Reset This is done by detect the modes and speeds at the second of both device is connected and capable of both 10Base T and 100Base TX devices can connect with the port in either Half or Full Duplex mode 1000Base T can be only connected in Full duplex mode 79 FGSW 2620VM FGSW 2624SF User s Manual 6 TROUBLESHOOTING This section is intended to help you solve the most common problems on the managed switch 6 1 Incorrect connections The switch port can auto detect straight or crossover cable when you link switch with other Ethernet device For the RJ 45 connector should use correct UTP or STP cable 10 100Mbps port use 2 pairs twisted cable If the RJ 45 connector is not correct pin on right position then the link will fail For fiber connection please notice that fiber cable mode and fiber module should be match 6 1 1 Faulty or loose cables Look for loose or obviously faulty connec
43. ds to requests from the switch The workstation must be running 802 1X compliant client software such as that offered in the Microsoft Windows XP operating system The client is the supplicant in the IEEE 802 1X specification e Authentication server performs the actual authentication of the client The authentication server validates the identity of the client and notifies the switch whether or not the client is authorized to access the LAN and switch services Because the switch acts as the proxy the authentication service is transparent to the client In this release the Remote Authentication Dial In User Service RADIUS security system with Extensible Authentication Protocol EAP extensions is the only supported authentication server it is available in Cisco Secure Access Control Server version 3 0 RADIUS operates in a client server model in which secure authentication information is exchanged between the RADIUS server and one or more RADIUS clients 63 FGSW 2620VM FGSW 2624SF User s Manual o Switch 802 1X device controls the physical access to the network based on the authentication status of the client The switch acts as an intermediary proxy between the client and the authentication server requesting identity information from the client verifying that information with the authentication server and relaying a response to the client The switch includes the RADIUS client which is responsible for encapsulating and decapsula
44. e button to change the port state activity Opposite is Passive A link having either two active LACP ports or one active port can perform dynamic LACP trunking A link has two passive LACP ports will not perform dynamic LACP trunking because both ports are waiting for and LACP protocol packet from the opposite device If you are active LACP s actor when you are select trunking port the active status will be created automatically 38 FGSW 2620VM FGSW 2624SF User s Manual 4 3 Switching In Switch page it has four parts of setting m VLAN B Rapid Spanning Tree m IGMP snooping R Forwarding table We will describe the configure detail in following 4 3 1 VLAN Understanding IEEE 802 1p Priority Priority tagging is a function defined by the IEEE 802 1p standard designed to provide a means of managing traffic on a network where many different types of data may be transmitted simultaneously It is intended to alleviate problems associated with the delivery of time critical data over congested networks The quality of applications that are dependent on such time critical data such as video conferencing can be severely and adversely affected by even very small delays in transmission Network devices that are in compliance with the IEEE 802 1p standard have the ability to recognize the priority level of data packets These devices can also assign a priority label or tag to packets Compliant devices can also strip priority
45. e unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 1000 Category 3 4 or 5 cable for 10Mbps connections or 1000 Category 5 cable for 100Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet 80 FGSW 2620VM FGSW 2624SF User s Manual APPENDIX A CABLE PIN ASSIGNMENT 7 1 Cable Cable Types and Specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5100 ohm UTP 100 m 328 ft RJ 45 100BASE TX Cat 5 100 ohm UTP 100 m 328 ft RJ 45 50 125 or 62 5 125 micron A 100BASE FK core multimode fiber MME 2 km 1 24 miles SC or ST 7 2 100BASE TX 10BASE T Pin Assignments With 100BASE TX 10BASE T cable pins 1 and 2 are used for transmitting data and pins 3 and 6 for receiving data RJ 45 Pin Assignments Pin Number Assignment 1 TX 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each wire pair All ports on this switch support automatic MDI MDI X operation you can use straight through cables for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data pl
46. e untagged traffic will be dropped Save button Press the button to save configurations 4 3 2 Rapid Spaning Tree 1 Spanning Tree Protocol The IEEE 802 1D Spanning Tree Protocol and IEEE 802 1W Rapid Spanning Tree Protocol allow for the blocking of links between switches that form loops within the network When multiple links between switches are detected a primary link is established Duplicated links are blocked from use and become standby links The protocol allows for the duplicate links to be used in the event of a failure of the primary link Once the Spanning Tree Protocol is configured and enabled primary links are established and duplicated links are blocked automatically The reactivation of the blocked links at the time of a primary link failure is also accomplished automatically without operator intervention This automatic network reconfiguration provides maximum uptime to network users However the concepts of the Spanning Tree Algorithm and protocol are a complicated and complex subject and must be fully researched and understood It is possible to cause serious degradation of the performance of the network if the Spanning Tree is incorrectly configured Please read the following before making any changes from the default values The Switch STP performs the following functions Creates a single spanning tree from any combination of switching or bridging elements Creates multiple spanning trees from any combi
47. ery of your data and allows you to prioritize certain applications across your network You can define exactly how you want the switch to treat selected applications and types of traffic You can use QoS on your system to o Control a wide variety of network traffic by o Classifying traffic based on packet attributes o Assigning priorities to traffic for example to set higher priorities to time critical or business critical applications o Applying security policy through traffic filtering Provide predictable throughput for multimedia applications such as video conferencing or voice over IP by minimizing delay and jitter Improve performance for specific types of traffic and preserve performance as the amount of traffic grows Reduce the need to constantly add bandwidth to the network Manage network congestion 4 4 1 QoS Configuration QoS settings allow customization of packet priority in order to facilitate delivery of data traffic that might be affected by latency problems The IEEE 802 1p Priority specification uses 8 priority levels to classify data packets In 802 1p compliant devices a tag inserted into the packet header is used to identify the priority level of data packets The Switch supports Static Port Ingress priority and four queues The screen in Figure 4 4 1 appears 60 FGSW 2620VM FGSW 2624SF User s Manual Qos Configuration HighestSecHigh SecLow Lowest 8 4 2 1 S
48. ggregate if work ports fail If it is local static trunk group the number must be as same as the group member ports Select the ports to join the trunk group Allow max four ports can be aggregated at the same time 4 2 5 2 Aggregator Information When you had setup the LACP aggregator you will see relation information in here Port Trunk Aggregator Information Group Key DE 4 Port Member 12 Figure 4 2 7 Trunking Aggregator Information interface Object Description Group Key Indicates the Static Trunking Groupd ID Port Member Indicates the selected ports that joined the Trunk group 37 FGSW 2620VM FGSW 2624SF User s Manual 4 2 5 3 Aggregator State Activity When you had setup the LACP aggregator you can configure port state activity You can mark or un mark the port Object Port Trunk State Activity LACP State Activity Port LACP State Activity 1 N A 2 N A a wa Tal N A 5 N A 6 N A s N A Ce N A 9 N A 10 N A Dix N A 42 N A as N A ER N A 15 N A 16 N A az N A 18 N A l19 N A 20 N A 21 N A 22 N A 23 N A 24 N A 25 N A 26 N A Figure 4 2 8 Trunking State Activity interface Description Active The port automatically sends LACP protocol packets Apply button The port does not automatically send LACP protocol packets and responds only if it receives LACP protocol packets from the opposite device Press th
49. h port stabilizes to the forwarding or blocking state No packets except BPDUs are forwarded from or received by STP enabled ports until the forwarding state is enabled for that port 2 STP Parameters STP Operation Levels The Switch allows for two levels of operation the switch level and the port level The switch level forms a spanning tree consisting of links between one or more switches The port level constructs a spanning tree consisting of groups of one or more ports The STP operates in much the same way for both levels 50 FGSW 2620VM FGSW 2624SF User s Manual Root Bridge and the Designated Bridges On the port level STP sets the Root Port and the Designated Ports On the switch level STP calculates the Bridge Identifier for each switch and then sets the The following are the user configurable STP parameters for the switch level Parameter Bridge Identifier Not user configurable except by setting priority below Priority Hello Time Maximum Age Timer Forward Delay Timer Description A combination of the User set priority and the switch s MAC address The Bridge Identifier consists of two parts a 16 bit priority and a 48 bit Ethernet MAC address 32768 MAC A relative priority for each switch lower numbers give a higher priority and a greater chance of a given switch being elected as the root bridge The length of time between broadcasts of the hello message by the switch Mea
50. her single VLAN If the port based VLAN enabled the VLAN tagging is ignored In order for an end station to send packets to different VLANs it itself has to be either capable of tagging packets it sends with VLAN tags or attached to a VLAN aware bridge that is capable of classifying and tagging the packet with different VLAN ID based on not only default PVID but also other information about the packet such as the protocol 1 Click the hyperlink VLAN Configuration to enter the VLAN configuration interface 2 Select PortBased at the VLAN Operation Mode to enable the port based VLAN function VLAN Configuration LAN Operation Mode PortBased v LAN Group ail leo Der Next Help Figure 4 3 1 VLAN PortBase interface Object Description You can configure the ID number of the VLAN by this item This field is used to add VLANs one at a time The VLAN group ID and available range is 2 4094 pen Indicate port 1 to port 26 Forbidden ports are not included in the VLAN Member Defines the interface as a Port Based member of a VLAN Add 3 Click Ado to create a new VLAN group Then the following figure appears 4 Enter the VLAN Group ID the available range is 2 4094 5 Select the members for the VLAN group Save Click button You will see the VLAN Group displays 43 FGSW 2620VM FGSW 2624SF User s Manual VLAN Operation Mode PortBased v PORT3 Y PORT12
51. hest Priority Hello Time The Hello Time can be from 1 to 10 seconds This is the interval between two transmissions of BPDU packets sent by the Root Bridge to tell all other Switches that it is indeed the Root Bridge If you set a Hello Time for your Switch and it is not the Root Bridge the set Hello Time will be used if and when your Switch becomes the Root Bridge The Hello Time cannot be longer than the Max Age Otherwise a configuration error will occur Note Max Age The Max Age can be from 6 to 40 seconds At the end of the Max Age if a BPDU has still not been received from the Root Bridge your Switch will start sending its own BPDU to all other Switches for permission to become the Root Bridge If it turns out that your Switch has the lowest Bridge Identifier it will become the Root Bridge Forward Delay Timer The Forward Delay can be from 4 to 30 seconds This is the time any port on the Switch spends in the listening state while moving from the blocking state to the forwarding state Observe the following formulas when setting the above parameters Max Age _ 2 x Forward Delay 1 second Max Age _ 2 x Hello Time 1 second Port Priority A Port Priority can be from 0 to 255 The lower the number the greater the probability the port will be chosen as the Root Port Port Cost A Port Cost can be set from 0 to 65535 The lower the number the greater the probability the port will be
52. ication 100Base FX SFP transceiver FGSW 2624SF 100Base FX SFP Slot only MNIFB FX SFP 100Base FX SFP transceiver Multi mode 2km TX 1300nm MEMFB F20 SFP 100Base FX SFP transceiver Single Mode 20km RX 1310nm MEMFB FA20 SFP 100Base FX SFP transceiver Single Mode WDM 20Km TX 1310nm MEMFB FB20 SFP 100Base FX SFP transceiver Single Mode WDM 20Km TX 1550nm 1000Base SX LX SFP transceiver MEMGB SX SFP 1000Base SX SFP transceiver Multi mode 220m MEMGB LX SFP 1000Base LX SFP transceiver Single Mode 10km MINGB L30 SFP 1000Base LX SFP transceiver Single Mode 30Km MINGB L50 SFP 1000Base LX SFP transceiver Single Mode 50Km 16 FGSW 2620VM FGSW 2624SF User s Manual It recommends using PLANET SFPs on the Managed Switch If you insert a SFP transceiver that is not supported the Managed Switch will not recognize it Before connect the other switches workstation or Media Converter 1 2 Make sure both side of the SFP transceiver are with the same media type for example 1000Base SX to 1000Base SX 1000Bas LX to 1000Base LX Check the fiber optic cable type match the SFP transceiver model gt To connect to 1000Base SX SFP transceiver use the multi mode fiber cable with one side must be male duplex LC connector type gt Toconnect to 1000Base LX SFP transceiver use the single mode fiber cable with one side must be male duplex LC connector ty
53. ire packet longer by 4 octets All of the information originally contained in the packet is retained 802 1Q Tag User Priority CFI VLAN ID VID 3 bits 1 bits 12 bits TPID Tag Protocol Identifier TCI Tag Control Information 2 bytes Preamble Destination Source VLAN TAG Ethernet Data FCS Address Address Type 6 bytes 6 bytes 4 bytes 2 bytes 46 1517 bytes 4 bytes The Ether Type and VLAN ID are inserted after the MAC source address but before the original Ether Type Length or Logical Link Control Because the packet is now a bit longer than it was originally the Cyclic Redundancy Check CRC must be recalculated Adding an IEEE802 1Q Tag Dest Addr Src Addr Length E type Data Old CRC Original Ethernet Dest Addr Src Addr E type Tag Length E type Data New CRC New Tagged Packet Priority CFI VLAN ID Port VLAN ID Packets that are tagged are carrying the 802 1Q VID information can be transmitted from one 802 1Q compliant network device to another with the VLAN information intact This allows 802 1Q VLAN to span network devices and indeed the entire network if all network devices are 802 1Q compliant 41 FGSW 2620VM FGSW 2624SF User s Manual Every physical port on a switch has a PVID 802 1Q ports are also assigned a PVID for use within the switch If no VLAN are defined on the switch all ports are then
54. is the percentage of the port s total bandwidth used by broadcast traffic When broadcast traffic for a port rises above the threshold you set broadcast storm control becomes active The valid threshold values are 1 2 1 4 1 8 1 16 and off Default is 1 4 Collision Retry Forever Provide Collision Retry Forever function Disable or Enable on Switch If this function is disabled when a packet meet a collision the Switch will retry 6 times before discard the packets Otherwise the Switch will retry until the packet is successfully sent Default mode is Enable MAC Table Auto Aging Fill in the number of seconds that an inactive MAC address remains in the Switch s address table The valid threshold values are 150 300 600 seconds and off Default is 300 seconds 24 FGSW 2620VM FGSW 2624SF User s Manual Hash Algorithm Provide MAC address table Hashing setting on Switch available options are CRC Hash and Direct Map Default mode is CRC Hash Save button Press the button to complete the configuration 4 1 2 IP Configuration User can configure the IP Settings and DHCP client function the screen in Figure 4 1 3 appears IP Configuration DHCP Client Disable vw mp address 192 168 0 100 ENTEROS 255 255 255 0 Gateway 0 0 0 0 Figure 4 1 3 IP configuration screenshot Object Description DHCP Client Enable is to get IP from DHCP server Disable is
55. ity flexibility and connectivity to the Core switch or Servers With its built in web based management the FGSW Managed Switch offers an easy to use platform independent management and configuration facility It supports standard Simple Network Management Protocol SNMP and can be managed via any standard based management software The IEEE 802 standard based firmware provides a rich set of features and ensures interoperability with equipment from other vendors Additionally the firmware includes advanced features such as IGMP snooping broadcast storm control Access Control List and MAC address filtering to enhance security and bandwidth utilization For efficient management the FGSW Managed Switch is equipped with web interface It can be programmed for basic switch management functions such as port speed configuration Port Trunking Port based VLAN Port Mirroring QoS bandwidth control Access Control list and Misc Configuration The FGSW Managed Switch provides port based VLAN including overlapping and 802 1Q tag based VLAN The VLAN groups allowed on the Managed Swith will be maximally up to 26 for port based VLAN Via supporting port trunking it allows the operation of a high speed trunk combining multiple ports The FGSW Managed Switch provides 13 groups of up to 8 ports for trunking and it supports fail over as well 2 1 1 Product Overview With its built in Web based management the PLANET FGSW Managed Switch offers
56. l ports on the Switch to the default As new VLAN are configured in Port based mode their respective member ports are removed from the default VLAN and Link aggregation Groups In order to use VLAN segmentation in conjunction with port link aggregation groups you can first set the port link aggregation group s and then you may configure VLAN settings If you wish to change the port link aggregation grouping with VLAN already in place you will not need to reconfigure the VLAN settings after changing the port link aggregation group settings VLAN settings will automatically change in conjunction with the change of the port link aggregation group settings 4 3 1 1 VLAN configuration A Virtual LAN VLAN is a logical network grouping that limits the broadcast domain It allows you to isolate network traffic so only members of the VLAN receive traffic from the same VLAN members Basically creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plug into the same switch physically The switch supports port based 802 1Q tagged based and protocol base VLAN in web management page In the default configuration VLAN support is disable 42 FGSW 2620VM FGSW 2624SF User s Manual 4 3 1 1 1 Port based VLAN Packets can go among only members of the same VLAN group Note all unselected ports are treated as belonging to anot
57. l that is incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at whose own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately Revision PLANET Managed Ethernet Switch User s Manual FOR MODELS FGSW 2620VM FGSW 2624SF v2 REVISION 1 1 AUGUST 2008
58. n Chuan Road Hsin Tien Taipei Taiwan R O C Person responsible for making this declaration Name Surname Kent Kang Position Title Product Manager d Le K ern ades Taiwan 26th Nov 2006 Place Date Legal Singnature
59. nation of ports contained within a single switch in user specified groups Automatically reconfigures the spanning tree to compensate for the failure addition or removal of any element in the tree Reconfigures the spanning tree without operator intervention 48 FGSW 2620VM FGSW 2624SF User s Manual Bridge Protocol Data Units For STP to arrive at a stable network topology the following information is used o The unique switch identifier o The path cost to the root associated with each switch port o The por tidentifier STP communicates between switches on the network using Bridge Protocol Data Units BPDUs Each BPDU contains the following information o The unique identifier of the switch that the transmitting switch currently believes is the root switch o The path cost to the root from the transmitting port o The port identifier of the transmitting port The switch sends BPDUs to communicate and construct the spanning tree topology All switches connected to the LAN on which the packet is transmitted will receive the BPDU BPDUs are not directly forwarded by the switch but the receiving switch uses the information in the frame to calculate a BPDU and if the topology changes initiates a BPDU transmission The communication between switches via BPDUs results in the following One switch is elected as the root switch The shortest distance to the root switch is calculated for each switch A designated switch i
60. nctions in an orderly manner Link aggregation lets you group up to eight consecutive ports into a single dedicated connection This feature can expand bandwidth to a device on the network LACP operation requires full duplex mode more detail information refers to IEEE 802 3ad 4 2 5 1 Aggregator setting This section provides Port Trunk Aggregator Setting of each port from the Switch the screen in Figure 4 2 6 appears Port Trunk Aggregator Setting Group ID Trunk Y omen Disable A gt PORTI Al PORT2 E PORT3 PORTS PORTE PORT PORTS PORTS ze O Figure 4 2 6 Aggregator setting interface Description System Priority A value used to identify the active LACP The switch with the lowest value has the highest priority and is selected as the active LACP There are seven trunk groups to provide configure Press the button to Choose the Group ID If enable the group is LACP static trunk group If disable the group is local static trunk group All ports support LACP dynamic trunking group If connecting to the device that also supports LACP the LACP dynamic trunking group will be created automatically If LACP enable you can configure LACP Active Passive status in each ports on State Activity page 36 FGSW 2620VM FGSW 2624SF User s Manual Allow max four ports can be aggregated at the same time If LACP static trunk group the exceed ports are standby and able to a
61. o the package Figure 2 5 shows how to attach brackets to one side of the Managed Switch 14 FGSW 2620VM FGSW 2624SF User s Manual Figure 2 5 Attach brackets to the Managed Switch You must use the screws supplied with the mounting brackets Damage caused to the parts by using incorrect screws would invalidate the warranty Step3 Secure the brackets tightly Step4 Follow the same steps to attach the second bracket to the opposite side Step5 After the brackets are attached to the Managed Switch use suitable screws to securely attach the brackets to the rack as shown in Figure 2 6 Figure 2 6 Mounting the Switch in a Rack Step6 Proceeds with the steps 4 and steps 5 of session 2 2 1 Desktop Installation to connect the network cabling and supply power to the Managed Switch 15 FGSW 2620VM FGSW 2624SF User s Manual 2 2 3 Installing the SFP transceiver The sections describe how to insert an SFP transceiver into an SFP slot The SFP transceivers are hot pluggable and hot swappable You can plug in and out the transceiver to from any SFP port without having to power down the Managed Switch As the Figure 2 7 appears 1000Base SX LX E LC Fiber E SAY Figure 2 7 Plug in the SFP transceiver Approved PLANET SFP Transceivers PLANET Managed Switches supports both single mode and multi mode SFP transceiver The following list of approved PLANET SFP transceivers is correct at the time of publ
62. on RB What is Access Control List An Access Control List ACL consists of a set of rules which are matched sequentially against a packet When a packet meets the match criteria of a rule the specified rule action Permit Deny is taken and the additional rules are not checked for a match On this sample the switch to which an ACL applies must be specified as well as whether it applies to inbound or outbound traffic Rules for the ACL are specified created using the ACL Rule Configuration menu R ACL Concepts Object Description mark Inputa group Beare O O Action To assign Permit or Deny for Access Control List IP Fragment To decide to check or Uncheck the IP fragment L4 Protocol Provide additional L4 protocol for security on Layer 4 level Current List Display IPv4 or Non IPv4 ACL groups maximum up to 16 groups Add button Press this button for add Access Control List group on Web Smart Switch Del button Press this button for delete Access Control List group on Web Smart Switch Access Control List MET VLAN am OviD 1 1 4094 any O 1p 0 0 0 0 Src IP Address z Ether Type Any Iv Type ox Mask 255 255 255 255 Any 1P 0 0 0 0 Mask 255 255 255 255 Ce O Any w pProtocols L4 Protocol d OTCP Any x Ports Dst IP Address Oupp Any w Port f gt q EE
63. onitor ports in the switch User can choose which port wants to monitor in only one mirror mode Press the button to apply all configurations If you want to disable the function you must select monitor port to none 33 FGSW 2620VM FGSW 2624SF User s Manual 4 2 3 Bandwidth Control This section provides current rate limit and traffic shapping status of each port from the Switch the screen in Figure 4 2 4 appears Bandwidth Control Rate Unit 1Mbps 0 disabled Figure 4 2 4 Bandwidth Control Screenshot Object Description Input the value of packet rate sent from the connected port to this port must enable the flow control feature of this port for the function to work normally The available value ranges from 1 to 99 and rate unit 1Mbps OutRate Input the value of packet rate sent from this port to the connected port The available value ranges from 1 to 99 and rate unit 1Mbps Save button Press the button to save all configurations 34 FGSW 2620VM FGSW 2624SF User s Manual 4 2 4 Port Statistics The following information provides a view of the current port statistic information Scroll down for more ports statistics Port Statistics Tx Good Tx Bad Rx Good Rx BadiRx Drop Tx Abort Packet Type Link State N Packet Packet Packet Packet Packet
64. opposite The DHCP client function only works if you haven t assigned a static IP address that different than the switch default IP Once the default IP has been changed the DHCP will not effective and the switch will continue using the manually entered static IP If you have changed the switch to a static IP address you can set the IP address back to its default IP address or you can reset the Switch back to factory default And then you can enable the DHCP client function to work IP Address Assign the Switch IP address The default IP is 192 168 0 100 subnet Mask Assign the Switch IP subnet mask Gateway Assign the Switch gateway The default value is 0 0 0 0 Apply button Press the button to complete the configuration 25 FGSW 2620VM FGSW 2624SF User s Manual 4 1 3 Account Password You can change web management login user name and password Account Password User Name New Password Confirm Password Figure 4 1 4 Account password screenshot Object Description Type the new user name The default is admin New Password Type the new password The default is admin Confirm password Retype the new password Apply button Press the button for save current User name and Password Setting on the Switch 26 FGSW 2620VM FGSW 2624SF User s Manual 4 1 4 SNMP Management The SNMP is a Protocol that governs the transceiver of information between management and agent The Switch su
65. ops in switched networks When STP enabled to ensure that only one path at a time is active between any two nodes on the network We are recommended that you enable STP on all switches ensures a single active path on the network 4 3 2 1 System Configuration This section provides RSTP System Configuration from the Switch the screen in Figure 4 3 6 appears RSTP System Configuration RSTP Mode Disable v Priority 0 61440 Max Age 6 40 Hello Time 1 10 Forward Delay Time 4 30 15 Priority must be a multiple of 4096 2 Forward Delay Time 1 should be greater than or equal to the Max Age The Max Age should be greater than or equal to 2 Hello Time 1 Root Bridge Information Bridge ID Root Priority Root Port Root Path Cost Max Age Hello Time Forward Delay Figure 4 3 6 Spanning Tree System Configuration interfac Object Description Disable or enable RSTP Assign path priority number The maximum path age The time that controls switch sends out the BPDU packet to check STP current status Forward Delay Time Forward delay time Apply button Press the button to save the modification 54 FGSW 2620VM FGSW 2624SF User s Manual 4 3 2 2 Per Port Configuration You can configure path cost and priority of every port RSTP Port Configuration Path Cost Priority Port Admin P2P Admin Edge Admin Non Stp 1 200000000 0
66. or OK then the home screen of the Web based management appears FGSW 2620VM FGSW 2620YM Welcome to Planet FGSW 2620VM 24 Port 10 100Mbps 2G TP SFP Combo Management Switch PLANET Technology Corporation 11F No 96 Min Chuan Road Hsin Tien Taipei Taiwan R O C Tel 886 2 2219 9518 Fax 886 2 2219 9528 E mail Support planet com tw Copyright 2006 PLANET Technology Corporation All rights reserved Figure 3 3 FGSW 2620VM Web Management Interface 21 FGSW 2620VM FGSW 2624SF User s Manual 3 5 Online Help You can click Help button when you have any configuration question during the configuring 3 6 View the Port Information You can direct click the port on the Switch figure on the top of web page Then you will see the port information Tx Good Packet Tx Bad Packet Rx Good Packet Rx Bad Packet Rx Drop Packet Tx Abort Packet Packet Collision Figure 3 4 Port information interface 22 FGSW 2620VM FGSW 2624SF User s Manual 4 WEB BASED MANAGEMENT To modify your PC s IP domain to the same with Managed Switch then use the default IP address 192 168 0 100 to remote configure Managed Switch through the Web interface A Notice The following section will base on the Web screens of FGSW 2620VM for F SW 2624SF the display will be the same to FGSW 2620VM 4 1 System In System it has seven parts of setting N System information N IP Configuration N Account Pass
67. pe Connect the fiber cable 1 Attach the duplex LC connector on the network cable into the SFP transceiver Connect the other end of the cable to a device switches with SFP installed fiber NIC on a workstation or a Media Converter Check the LNK ACT LED of the SFP slot on the front of the Switch Ensure that the SFP transceiver is operating correctly Check the Link mode of the SFP port if the link failed Co works with some fiber NICs or Media Converters set the Link mode to 1000 Force is needed Remove the transceiver module L Make sure there is no network activity by consult or check with the network administrator Or through the management interface of the switch converter if available to disable the port in advance Remove the Fiber Optic Cable gently Turn the handle of the MGB module to horizontal Pull out the module gently through the handle 17 FGSW 2620VM FGSW 2624SF User s Manual 4 E MGB SX LX Figure 2 8 Pull out the SFP transceiver Never pull out the module without pull the handle or the push bolts on the module Direct pull out the module with violent could damage the module and SFP module slot of the Managed Switch 18 FGSW 2620VM FGSW 2624SF User s Manual 3 SWITCH MANAGEMENT This section introduces the configuration and functions of the Web Based management The following configuration descriptions are based on the kernel software version 1 07
68. pports SNMP V1 You can define management stations as trap managers and to enter SNMP community strings You also can define a name location and contact person for the Switch Fill in the system options data and then click Apply to update the changes 4 1 4 1 System Configuration Community strings serve as password SNMP System Configuration Community Strings Current Strings New Community String Remove public_ RO private_ RW Figure 4 1 5 SNMP System Configuration screenshot Object Description Fill the name of string Read only Enables requests accompanied by this string to display MIB object information Read write Enables requests accompanied by this string to display MIB object information and to set MIB objects Add button Press the button to add the management SNMP community strings on the Switch Remove button Press the button to remove the management SNMP community strings on the Switch 27 FGSW 2620VM FGSW 2624SF User s Manual 4 1 4 2 Trap Configuration Trap Manager Atrap manager is a management station that receives traps the system alerts generated by the switch If no trap manager is defined no traps will issue Create a trap manager by entering the IP address of the station and a community string SNMP Trap Configuration _ Trap Managers Current Managers New Manager Remove 192 168 0 88 public wi Lo D Figure 4
69. raffic classifiers 4 5 Security In Security page it has five parts of setting B 802 1x Radius Access control list Static MAC address MAC filter IP security We will describe the configure detail in following 62 FGSW 2620VM FGSW 2624SF User s Manual 4 5 1 802 1x Radius Understanding IEEE 802 1X Port Based Authentication The IEEE 802 1X standard defines a client server based access control and authentication protocol that restricts unauthorized clients from connecting to a LAN through publicly accessible ports The authentication server authenticates each client connected to a switch port before making available any services offered by the switch or the LAN Until the client is authenticated 802 1X access control allows only Extensible Authentication Protocol over LAN EAPOL traffic through the port to which the client is connected After authentication is successful normal traffic can pass through the port This section includes this conceptual information e Device Roles e Authentication Initiation and Message Exchange e Ports in Authorized and Unauthorized States E Device Roles With 802 1X port based authentication the devices in the network have specific roles as shown below ON Authentication a server SE 802 1X Ee sv vitch RAD IUS Workstations PARO clients RI SI o Client the device workstation that requests access to the LAN and switch services and respon
70. rocess that is making the request principally the process s user identifier Access Control List ACL is a mechanism that implements access control for a system resource by listing the identities of the system entities that are permitted or denied to access the resource The screen in following screen appears Access Control List Permit any Cup 1 14098 Dany Oi 0 0 0 0 A Src IP Address e STATER Am Y Type Ox Mask 255 255 255 255 Zan O1p 0 0 0 0 Dst IP Address Mask 255 255 255 255 IP Fragment Uncheck ze f Any x Protocol L4 Protocol OTCP Any v parre E Cup Any Y porta SrcIP Mask DstIP Mask L4 Protocol IP Fragment Figure 4 5 4 Access Control List ACL Web Page screen Object Description Groupid Input a group ID and available range is 1 255 To assign Permit or Deny for Access Control List VLAN To choose VLAN type as Any or by VID 1 4094 Packet Type To choose Packet type as IPv4 or by Non IPv4 IP Fragment To decide to check or Uncheck the IP fragment Provide additional L4 protocol for security on Layer 4 level Display IPv4 or Non IPv4 ACL groups maximum up to 16 groups 74 FGSW 2620VM FGSW 2624SF User s Manual 4 5 3 Static MAC Address When you a
71. rocessing Scheme Store and Forward Throughput packet per 6 547Mpps second Seb fabrie 88Obps o O Back pressure for Half Duplex IEEE 802 3x Pause Frame for Full Duplex Dimensions 440 x 120 x 44 mm 1U height 440 x 220 x 44 mm 1U height 1 87kg 2 6kg 100 240V AC 50 60 Hz 100 240V AC 50 60 Hz Power Consumption 13 5 Watts maximum 46 BTU hr 23 1 Watts maximum 78 BTU hr Dissipation maximum maximum Flow Control Operating 0 50 degree C Storage 40 70 degree C Humidity Operating 10 to 90 Storage 5 to 95 Non condensing Layer 2 Function Web Browser Management Interface SNMP Monitor SNMP Trap Per port disable enable S X Auto negotiation disable enable Port Configuration h Flow control disable enable Bandwidih control on each port Display per port s disable enable status Per port s link status and speed duplex mode Flow control status Static Port Trunk Trunk Configuration IEEE 802 3ad LACP Link Aggregation Control Protocol Support 13 groups of maximum 8 Port trunk IEEE 802 1Q Tag Based VLAN VLAN Configuration Port based VLAN Supports maximum up to 26 VLAN groups Spanning Tree Protocol IEEE 802 1W Rapid Spanning Tree aie One Mirroring port to monitor one mirrored port The monitor modes are RX TX Port Monitoring Gees an FGSW 2620VM FGSW 2624SF User s Manual IGMP Snoopin Supports v1 and v2 protocol eh Supports IGMP Querier 4 priority queues per port QoS Configuration IEEE 8
72. rt gt Control Panel double click on Network Connections 2 Right click on the Local Network Connection 3 Click Properties to open up the Properties setting window 70 FGSW 2620VM FGSW 2624SF User s Manual 3COM 3C 940 Status General KE upport Connection Status Connected Duration 03 35 37 Speed 100 0 Mbps Activity Sent A Received 146 938 760 110 212 126 4 Select Authentication tab 5 Select Enable network access control using IEEE 802 1X to enable 802 1x authentication 4 3COM 3C940 Properties General Authentication Advanced Select this option to provide authenticated network access for Ethernet networks Enable IEEE 802 1x authentication for this network EAP type Protected EAP PEAP v MD5 Challenge Protected EAP PEAP Smart Card or other Certificate Authenticate as computer when computer information is available C Authenticate as quest when user or computer information is unavailable 6 Select MD 5 Challenge from the drop down list box for EAP type 7 Click OK 8 When client has associated with the switch a user authentication notice appears in system tray Click on the notice to continue 71 FGSW 2620VM FGSW 2624SF User s Manual L Wireless Network Connection x Click hereto enter your user name and password For the retwork PLANET AP 9 Enter the user name password and the logon domain
73. rver check boxes will then be available Security IP1 5 Assign up to 5 specific IP address Only these 5 IP address can access and manage the switch through the Web browser Apply button Press the button to apply the configuration 77 FGSW 2620VM FGSW 2624SF User s Manual 5 SWITCH OPERATION 5 1 Address Table The Switch is implemented with an address table This address table composed of many entries Each entry is used to store the address information of some node in network including MAC address port no etc This information comes from the learning process of Ethernet Switch 5 2 Learning When one packet comes in from any port The Switch will record the source address port no And the other related information in address table This information will be used to decide either forwarding or filtering for future packets 5 3 Forwarding Filtering When one packet comes from some port of the Ethernet Switching it will also check the destination address besides the source address learning The Ethernet Switching will lookup the address table for the destination address If not found this packet will be forwarded to all the other ports except the port which this packet comes in And these ports will transmit this packet to the network it connected If found and the destination address is located at different port from this packet comes in the Ethernet Switching will forward this packet to the port where this des
74. s in the unauthorized state While in this state the port disallows all ingress and egress traffic except for 802 1X protocol packets When a client is successfully authenticated the port transitions to the authorized state allowing all traffic for the client to flow normally If a client that does not support 802 1X is connected to an unauthorized 802 1X port the switch requests the client s identity In this situation the client does not respond to the request the port remains in the unauthorized state and the client is not granted access to the network In contrast when an 802 1X enabled client connects to a port that is not running the 802 1X protocol the client initiates the authentication process by sending the EAPOL start frame When no response is received the client sends the request for a fixed number of times Because no response is received the client begins sending frames as if the port is in the authorized state If the client is successfully authenticated receives an Accept frame from the authentication server the port state changes to authorized and all frames from the authenticated client are allowed through the port If the authentication fails the port remains in the unauthorized state but authentication can be retried If the authentication server cannot be reached the switch can retransmit the request If no response is received from the server after the specified number of attempts authentication fails and ne
75. s selected This is the switch closest to the root switch through which packets will be forwarded to the root A port for each switch is selected This is the port providing the best path from the switch to the root switch Ports included in the STP are selected Creating a Stable STP Topology It is to make the root port a fastest link If all switches have STP enabled with default settings the switch with the lowest MAC address in the network will become the root switch By increasing the priority lowering the priority number of the best switch STP can be forced to select the best switch as the root switch When STP is enabled using the default parameters the path between source and destination stations in a switched network might not be ideal For instance connecting higher speed links to a port that has a higher number than the current root port can cause a root port change STP Port States The BPDUs take some time to pass through a network This propagation delay can result in topology changes where a port that transitioned directly from a Blocking state to a Forwarding state could create temporary data loops Ports must wait for new network topology information to propagate throughout the network before starting to forward packets They must also wait for the packet lifetime to expire for BPDU packets that were forwarded based on the old topology The forward delay timer is used to allow the network topology to stabilize after a
76. sessions with the specified radius server This key must match the encryption key used on the Radius Server Set the identifier for the radius client 3 Setup the RADIUS server and assign the client IP address to the Web Smart switch In this case field in the default IP Address of the Web Smart switch with 192 168 0 100 And also make sure the shared secret key is as same as the one you had set at the switch RADIUS server 12345678 at this case Add RADIUS Client xi Uert Information Specify information regarding the client Client addiess IP or DNS 192 168 0 100 Verify ChertAendor FADIUS Standard I Client must always send the signature attribute in the equest Shared secret ha Confirm shared secret Sa lt Back Cancel 4 Configure ports attribute of 802 1X see the next section Per Port Status Configuration 67 4 5 1 2 Per port Configuration FGSW 2620VM FGSW 2624SF User s Manual You can see the every port Authorization information list in table Per Port Configuration Authorize v Port Authorization Port State Port 1 Disable Port 2 Disable Port 3 Disable Port 4 Disable Port 5 Disable Port 6 Disable Port Disable Port 8 Disable Figure 4 5 2 802 1x Configuration Per Port Configuration Object Description pen Choose the port to set port Authorization Reject the specified port is required to be held in the Unauthorized state Accept
77. st 4 Portcast 4 Portcast 4 4 y 4 B Port 1 C Port 1 Bridge ID 30 Bridge ID 20 g K P gt E gt E K Port 2 bot 3 lt Portcast 19 gt Pon 2 Pong XQ E E P a SS Portcast 19 Portcast 19 LAN 2 gt mM LAN3 gt gt Before Applying the STA Rules In this example only the default STP values are used LAN I A Port 3 gt Root Bridge 4 E gt Porti Port 2 E Designated Port Designated Port Root Port Root Port B Port 1 pon L BR E Designated Bridge K E S y K A K Port 2 Pong el Blocked Lk Pont 2 Port3 lt a L y lt J J K LAN gt lt LAN 3 After Applying the STA Rules The switch with the lowest Bridge ID switch C was elected the root bridge and the ports were selected to give a high port cost between switches B and C The two optional Gigabit ports default port cost 4 on switch A are connected to 53 FGSW 2620VM FGSW 2624SF User s Manual one optional Gigabit port on both switch B and C The redundant link between switch B and C is deliberately chosen as a 100 Mbps Fast Ethernet link default port cost 19 Gigabit ports could be used but the port cost should be increased from the default to ensure that the link between switch B and switch C is the blocked link The Spanning Tree Protocol STP is a standardized method IEEE 802 1d for avoiding lo
78. sure Half Duplex and 802 3x PAUSE frame Flow Control Full Duplex High performance Store and Forward architecture broadcast storm control runt CRC filtering eliminates erroneous packets to optimize the network bandwidth 8K MAC address table automatic source address learning and ageing Port Based VLAN and IEEE 802 1Q Tagged VLAN IEEE 802 3ad Port trunk with LACP and Static Port Trunk IEEE 802 1w Spanning tree protocol IGMP snooping and IGMP Query mode for Multi media application Broadcast storm filter Port mirroring allows monitoring of the traffic across any port in real time Quality of Service Supports QoS and bandwidth control on each port IEEE 802 1p class of service support Strict and WRR mode Security Supports Access Control List function MAC Filter and Static MAC IP Security for management security IEEE 802 1x Port Based authentication Management Web interface for Switch basic management and setup Supports SNMP v1 switch management SNMP trap for interface Link Up and Link Down notification FGSW 2620VM FGSW 2624SF User s Manual B 19 inch rack mount size DW EMI standards comply with FCC CE class A 1 4 Product Specification Hardware Specification 24 10 100Base TX RJ 45 10 100Mbps Ports Bas 24 100Base FX SFP slots Auto MDI MDI X ports 1000Mbps Copper ports 2 10 100 1000Base T RJ 45 Auto MDI MDI X ports SFP mini GBIC Slots 2 1000Base SX LX SFP slots shared with Port 25 and Port 26 Switch P
79. sures the age of a received BPDU for a port and ensures that the BPDU is discarded when its age exceeds the value of the maximum age timer The amount time spent by a port in the learning and listening states waiting for a BPDU that may return the port to the blocking state The following are the user configurable STP parameters for the port or port group level Variable Port Priority Port Cost Description A relative priority for each port lower numbers give a higher priority and a greater chance of a given port being elected as the root port A value used by STP to evaluate paths STP calculates path costs and selects the path with the minimum cost as the active path Default Spanning Tree Configuration Feature Enable state Port priority Port cost Bridge Priority Default Value STP enabled for all ports 128 19 32 768 51 Default Value 32768 MAC 32768 2 seconds 20 seconds 15 seconds Default Value 32768 19 100Mbps Fast Ethernet ports 4 1000Mbps Gigabit Ethernet ports FGSW 2620VM FGSW 2624SF User s Manual User Changeable STA Parameters The Switch s factory default setting should cover the majority of installations However it is advisable to keep the default settings as set at the factory unless it is absolutely necessary The user changeable parameters in the Switch are as follows Priority A Priority for the switch can be set from 0 to 65535 0 is equal to the hig
80. tatic Port Ingress Priority PORT4 OFF PORT22 OFF PORT1S PORT13 PORT6 PORT24 OFF PORT17 OFF v PORT25 PORT10 OFF v PORT19 OFF ze mr ore ORIBO oF lt 802 1p Priority 7 0 Highest v Highest y SecHigh sl SecHigh sl SecLow y SecLow v Lowset v Lowset v Figure 4 4 1 QoS Configuration Web Page screen 61 FGSW 2620VM FGSW 2624SF User s Manual Object Description QoS Mode Provide different modes for QoS Configuration the available options are shown as below Disable QoS Priority High Empty Then Low Highest secHigh SecLow Lowest 8 4 2 1 Highest secHigh SecLow Lowest 15 7 3 1 Highest secHigh SecLow Lowest 15 10 5 1 Default mode is Highest secHigh SecLow Lowest 8 4 2 1 Static Port Ingress Allow to assign Ingress priority on each port of the Switch the available options are OFF and Priority 0 7 Default mode is 0 802 1p Priority 7 0 Allow assign high and low on each priority the available options are shown as below Lowest SecLow SecHigh Highest Save button Press this button for save current QoS configuration of each port on the Switch 802 1p Priority Priority classifiers of the Switch forward packet COS range is from 0 to 7 Seven is the high class Zero is the less class The user may configure the mapping between COS and T
81. tep1 Attach the rubber feet to the recessed areas on the bottom of the Managed Switch Step2 Place the Managed Switch on the desktop or the shelf near an AC power source Step3 Keep enough ventilation space between the Managed Switch and the surrounding objects When choosing a location please keep in mind the environmental restrictions discussed in Chapter 1 Section 4 in Specification Step4 Connect the Managed Switch to network devices A Connect one end of a standard network cable to the 10 100 1000 RJ 45 ports on the front of the Managed Switch B Connect the other end of the cable to the network devices such as printer servers workstations or routers etc Connection to the Managed Switch requires UTP Category 5 network cabling with RJ 45 tips For more information please see the Cabling Specification in Appendix A Note Step5 Supply power to the Managed Switch A Connect one end of the power cable to the Managed Switch B Connect the power plug of the power cable to a standard wall outlet When the Managed Switch receives power the Power LED should remain solid Green 2 2 2 Rack Mounting To install the Managed Switch in a 19 inch standard rack please follows the instructions described below Step1 Place the Switch on a hard flat surface with the front panel positioned towards the front side Step2 Attach the rack mount bracket to each side of the Managed Switch with supplied screws attached t
82. that your account belongs 10 Click OK to complete the validation process Wireless Network Connection User name test Password AKKA Logon doman FAE LOCAL 72 FGSW 2620VM FGSW 2624SF User s Manual 4 5 1 4 Misc Configuration The section provides 802 1x Misc Configuration the screen in Figure 4 5 3 802 1x Quiet Period Tx Period Supplicant Timeout Server Timeout Max Requests Figure 4 5 3 802 1x Configuration Misc Configuration interface Object Description Tx Period Set the period the port waits to retransmit next EAPOL PDU during an authentication session Supplicant Timeout Set the period of time the switch waits for a supplicant response to an EAP request Server Timeout Set the period of time the switch waits for a server response to an authentication request Max Requests Set the number of authentication that must time out before authentication fails and the authentication session ends Reauth Period Set the period of time after which clients connected must be re authenticated Apply Button Press this button to save the 802 1x s value on the Switch 73 FGSW 2620VM FGSW 2624SF User s Manual 4 5 2 Access Control List The Access Control List ACL is a concept in computer security used to enforce privilege separation It is a means of determining the appropriate access rights to a given object depending on certain aspects of the p
83. tination address is located according to the information from address table But if the destination address is located at the same port with this packet comes in then this packet will be filtered Thereby increasing the network throughput and availability 5 4 Store and Forward Store and Forward is one type of packet forwarding techniques A Store and Forward Ethernet Switching stores the incoming frame in an internal buffer do the complete error checking before transmission Therefore no error packets occurrence it is the best choice when a network needs efficiency and stability The Ethernet Switch scans the destination address from the packet header searches the routing table provided for the incoming port and forwards the packet only if required The fast forwarding makes the switch attractive for connecting servers directly to the network thereby increasing throughput and availability However the switch is most commonly used to segment existing hubs which nearly always improves overall performance An Ethernet Switching can be easily configured in any Ethernet network environment to significantly boost bandwidth using conventional cabling and adapters 78 FGSW 2620VM FGSW 2624SF User s Manual Due to the learning function of the Ethernet switching the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table This information is subsequently used to filter packets whose
84. ting the Extensible Authentication Protocol EAP frames and interacting with the authentication server When the switch receives EAPOL frames and relays them to the authentication server the Ethernet header is stripped and the remaining EAP frame is re encapsulated in the RADIUS format The EAP frames are not modified or examined during encapsulation and the authentication server must support EAP within the native frame format When the switch receives frames from the authentication server the server s frame header is removed leaving the EAP frame which is then encapsulated for Ethernet and sent to the client a Authentication Initiation and Message Exchange The switch or the client can initiate authentication If you enable authentication on a port by using the dot1x port control auto interface configuration command the switch must initiate authentication when it determines that the port link state transitions from down to up It then sends an EAP request identity frame to the client to request its identity typically the switch sends an initial identity request frame followed by one or more requests for authentication information Upon receipt of the frame the client responds with an EAP response identity frame However if during bootup the client does not receive an EAP request identity frame from the switch the client can initiate authentication by sending an EAPOL start frame which prompts the switch to request the client s identity
85. tions If they appear to be OK make sure the connections are snug IF that does not correct the problem try a different cable 6 1 2 Non standard cables Non standard and miss wired cables may cause numerous network collisions and other network problem and can seriously impair network performance A category 5 cable tester is a recommended tool for every 100Base T network installation 6 1 3 Improper Network Topologies It is important to make sure that you have a valid network topology Common topology faults include excessive cable length and too many repeaters hubs between end nodes In addition you should make sure that your network topology contains no data path loops Between any two ends nodes there should be only one active cabling path at any time Data path loops will cause broadcast storms that will severely impact your network performance 6 2 Diagnosing LED Indicators The Switch can be easily monitored through panel indicators to assist in identifying problems which describes common problems you may encounter and where you can find possible solutions IF the power indicator does turn on when the power cord is plugged in you may have a problem with power outlet or power cord However if the Switch powers off after running for a while check for loose power connections power losses or surges at power outlet IF you still cannot resolve the problem contact your local dealer for assistance 6 2 1 Cabling RJ 45 ports us
86. topology change In addition STP specifies a series of states a port must transition through to further ensure that a stable network topology is created after a topology change Each port on a switch using STP exists is in one of the following five states Blocking the port is blocked from forwarding or receiving packets 49 FGSW 2620VM FGSW 2624SF User s Manual o Listening the port is waiting to receive BPDU packets that may tell the port to go back to the blocking state o _ Learning the port is adding addresses to its forwarding database but not yet forwarding packets o Forwarding the port is forwarding packets o Disabled the port only responds to network management messages and must return to the blocking state first A port transitions from one state to another as follows o From initialization switch boot to blocking o From blocking to listening or to disabled o From listening to learning or to disabled o From learning to forwarding or to disabled o From forwarding to disabled o From disabled to blocking Switch Blocking lt Listening Disable A Learning Vv Forwarding STP Port State Transitions You can modify each port state by using management software When you enable STP every port on every switch in the network goes through the blocking state and then transitions through the states of listening and learning at power up If properly configured eac
87. ts and all devices connected to the Switch will be affected This priority queuing system will be especially beneficial if your network employs switches with the capability of assigning priority tags 39 FGSW 2620VM FGSW 2624SF User s Manual VLAN Description A Virtual Local Area Network VLAN is a network topology configured according to a logical scheme rather than the physical layout VLAN can be used to combine any collection of LAN segments into an autonomous user group that appears as a single LAN VLAN also logically segment the network into different broadcast domains so that packets are forwarded only between ports within the VLAN Typically a VLAN corresponds to a particular subnet although not necessarily VLAN can enhance performance by conserving bandwidth and improve security by limiting traffic to specific domains A VLAN is a collection of end nodes grouped by logic instead of physical location End nodes that frequently communicate with each other are assigned to the same VLAN regardless of where they are physically on the network Logically a VLAN can be equated to a broadcast domain because broadcast packets are forwarded to only members of the VLAN on which the broadcast was initiated Port based VLAN Port based VLAN limit traffic that flows into and out of switch ports Thus all devices connected to a port are members of the VLAN s the port belongs to whether there is a single computer directly connected to
88. twork access is not granted When a client logs off it sends an EAPOL logoff message causing the switch port to transition to the unauthorized state 65 FGSW 2620VM FGSW 2624SF User s Manual If the link state of a port transitions from up to down or if an EAPOL logoff frame is received the port returns to the unauthorized state 4 5 1 1 System Configuration The section provides 802 1x System Configuration the screen in Figure 4 5 1 802 1x 802 1x Protocol Disable v Radius Server IP 0 0 0 0 Server Port 11812 Accounting Port 1813 shared Ke 12345678 dE NAS_L2_SWITCH Figure 4 5 1 802 1x Configuration System Configuration interface Radius Server In this situation need a Radius server in the network the normal topologies as below R Authentication server 802 1X RADIUS switch emm Workstations clients 1 Select the Radius Server mode 2 The RADIUS Server configuration table includes the following fields 66 FGSW 2620VM FGSW 2624SF User s Manual Object Description 802 1x Protocol Disable or enable 802 1x Protocol Radius Server IP Set the Radius Server IP address Server Port Set the UDP destination port for authentication requests to the specified Radius Server Set the UDP destination port for accounting requests to the specified Radius Server Shared Key Set an encryption key for use during authentication
89. up ID and available range is 2 4094 5 Select specific port as member port and the screen in Figure 4 3 4 appears 45 FGSW 2620VM FGSW 2624SF User s Manual VLAN Configuration VLAN Operation Mode 80210 el PORTS A A ada Group Member SIA l Mporr12 PORT14 PORT16 aa ae emmer Spon M PORT20 v Figure 4 3 4 802 1Q VLAN Setting Web Page screen Object Description You can configure the ID number of the VLAN by this item This field is used to add VLANs one at a time The VLAN group ID and available range is 2 4094 pen Indicate port 1 to port 26 Forbidden ports are not included in the VLAN Untagged Packets forwarded by the interface are untagged Defines the interface as a tagged member of a VLAN All packets forwarded by the interface are tagged The packets contain VLAN information 6 After setup completed please press Save button to take effect 7 Please press Back for return to VLAN configuration screen to add other VLAN group the screen in Figure 4 3 3 appears 8 If there are many groups that over the limit of one page you can click Next to view other VLAN groups 9 Use Del button to delete unwanted VLAN 10 Use Edit button to modify existing VLAN group SS Eable 802 1Q VLAN the all ports on the switch belong to default VLAN VID is 1 The default VLAN can
90. us TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD 81 FGSW 2620VM FGSW 2624SF User s Manual 7 3 RJ 45 cable pin assignment KS The standard RJ 45 receptacle connector There are 8 wires on a standard UTP STP cable and each wire is color coded The following shows the pin allocation and color of straight cable and crossover cable connection Straight Cable 1 2 3 4 5 6 7 8 SIDE1 1 2 3 4 5 6 7 8 SIDE 2 Straight Cable 1 2 3 4 5 6 7 8 SIDE1 1 2 3 4 5 6 7 8 SIDE 2 SIDE 1 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown SIDE 1 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown SIDE2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown SIDE2 1 White Orange 2 Green 3 White Orange 4 Blue 5 White Blue 6 Orange 7 White Brown 8 Brown Figure 7 1 Straight Through and Crossover Cable Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network 82 FGSW 2620VM FGSW 2624SF User s Manual Appendix B Access Control List Application Guide Introducti
91. word N SNMP Management N TFTP Upgrade N Factory Default N System Reboot We will describe the configure detail in following 4 1 1 System Information In System information it has two parts of setting basic and advanced We will describe the configure detail in following 4 1 1 1 Basic In Basic switch setting it displays the Switch basic information Switch Settings System Name L System Description PLANET FGSW 2620YM Web Smart Switch Tarren tse HAC Address 00304F010203 Figure 4 1 1 Switch setting screenshot 23 FGSW 2620VM FGSW 2624SF User s Manual Object Description System Description The description of Switch System Location The Switch physical location Kernel Version The kernel software version Firmware Version The Switch s firmware version MAC Address The unique hardware address assigned by manufacturer default Apply button Press the button to complete the configuration 4 1 1 2 Advanced Choose Advanced from System Information of Managed Switch the screen in Figure 4 1 2 appears Switch Setting iBroadcast Storm Filter Mode OFF v Collisions Retry Forever Enable v MAC Table Auto Aging 300 sec v Hash Algorithm CRC Hash ze Figure 4 1 2 Switch Advanced setting screenshot Object Description Broadcast Storm Filter Mode Configure broadcast storm control Enable it and set the upper threshold for individual ports The threshold

Download Pdf Manuals

image

Related Search

Related Contents

SD 300 pH - Lovibond Tintometer  Manual - Controle - Inversor de Frequencia EDS  Ethan Frome    Hyundai H-CDM8047 User's Manual  Nokia 2300 Cell Phone User Manual  manual for installation and use 121-053  Planet Technology 802.11nWireless User's Manual  use and care guide guide d`utilisation et d`entretien  