1. Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state REVISION HISTORY Manual Date Comments C1972M 11 04 Original version Pelco the Pelco logo Spectra Genex Esprit Camclosure and Legacy are registered trademarks of Pelco If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit
2. high and rack mountable You can fill the empty module slots on either chassis with single width blank modules RK5001B 3U and double width blank modules RK50002B 3U MODELS RK5000PS 3U Rack mountable chassis with power supply 3 RU RK5000 3U Rack mountable chassis 3 RU external power supply required C1972M 11 04 FRONT VIEW RK5000PS 3U 1 Rack Ears 2 2 Power Supply Module Slots 12 O Alarm from Module LED O Power Fail LED O Pelco Badge Figure 1 RK5000PS 3U Front View BACK VIEW RK5000PS 3U 1 Thumbscrews for Fastening Modules 12 2 External Connector for Redundant Power Supply Relay Output Connector with Screw Terminal O Power Button O Power Cord Connector PY 2 D0 2 0 0 IDAD0020 0_20_4 Figure 2 RK5000PS 3U Back View 8 C1972M 11 04 FRONT VIEW RK5000 3U 1 Rack Ears 2 2 Module Slots 14 Figure 3 RK5000 3U Front View BACK VIEW RK5000 3U 1 External Connector for Redundant Power Supply O Thumbscrews for Fastening Modules 14 HD 0200 00 YD 0000 08 1 Figure 4 RK5000 3U Back View C1972M 11 04 Installation PACKAGE CONTENTS RK5000PS 3U 1 Rack mount chassis 4 Screws and washers for rack mounting RK5000 3U 1 Rack mount chassis 4 Screws and washers for rac
3. the power supplies that are provided with the Fiber modules with the power bus on the RK5000PS 3U can cause damage to the unit To remove the power bus follow these steps and refer to Figure 8 1 Turn off the power supply 2 Remove the power supply 3 Unscrew the five Phillips flat head screws Figure 8 Power Bus Removal 12 C1972M 11 04 REPLACING AN INTERNAL POWER SUPPLY You can easily replace the internal power supply in the RK5000PS 3U in case of failure The front of the power supply has two LEDs The top LED turns red when there is an alarm condition from one of the modules The bottom LED turns red when the power supply fails To replace an internal power supply follow these steps and refer to Figure 9 C1972M 11 04 1 2 3 Unplug the power cord Unscrew the two thumbscrews on the back of the chassis that hold the power supply Remove the power supply Insert the new power supply Secure the power supply by tightening the two thumbscrews on the back of the chassis Plug in the power cord Turn on the power supply Figure 9 Internal Power Supply Replacement Specifications RK5000PS 3U ELECTRICAL Input Voltage Output Voltage Power Consumption Fuse Redundant Capability MECHANICAL Number of Slots Module Orientation Rack Units Construction Finish GENERAL Operating Temperature Operating Humidity Storage Humidity Dimensions Mounting Unit Weight
4. 04 Important Safety Instructions 20 21 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Unplug this apparatus during lightning storms or when unused for long periods of time Refer all servicing to qualified service personnel Servicing is required when the apparatus has
5. INSTALLATION RK5000PS 3U RK5000 3U Rack Mount Chassis For Fiber Optic Modules C1972M 11 04 Contents Important Safety Ee EE Regulatory NOUCES aere es EE a Ae ae odes Gett Sead Ee DESCAPLON eeh dete cack ee ENEE AE E cle See SE A cee A Ges aerate eects Modela ee E A E E EREE E EE E E A R E A O S Front View RK5000PS 3U 2 0 nen EEEE EEE EEE EEEE EEEE EEEE EEEE EEEE EEEE EEEE Back View RK5000PS 3U jup scare dated ger gegen aer EE dai ETE re A Front Mekic a ed Back View RKS000 30 iia ia tai eer eet ws STAN AMONG EE 1 Package Contents 1 Mo ntinga Chassis ees A gie ees Se E Eh dE eet ee E E TEE dE SEA Ed 1 Installing a Module EES AE E e EEN 1 Installingia Blank Module 00000000 ld dd EE AR did e dde 1 SONICO arandelas iodo EE 1 Removing the POWer BUS diesem erg Sage deet Sie ds Gee ia 1 Replacing an Internal Power SUPP ses Acid cadena AAA a ENEE EE ene Rene EE 1 EI ee EE 1 C1972M 11 04 List of Illustrations 1 RK5000PS 3UEront NIE acc sus Sege Set A Dag goatee dee EISEN oad m ede nee se 8 Z SRK SOOOPS SUIB ACK MEW ace RE de Ad sah doh ey acer ob Atos ege 8 SEENEN eee aces ct cet eles tras ates s dead ere tate IS E GE EE 9 A A RC O 9 5 Mounting an RK5000PS 3U RK5000 3U into a Back 10 6 Module Installation 11 7 Blank Module Installation 11 8 Power Bus Removal 0 nananana aE 12 9 Joers Power Supply Replacement coo tenens cerie inanon he EE E EE ENEE EE ee See eeh eee 13 4 C1972M 10
6. RK5000 3U MECHANICAL Number of Slots Module Orientation Rack Units Construction Finish GENERAL Dimensions Mounting Unit Weight 100 240 VAC 12 VDC 120 watts maximum 16A Yes with optional EPS5000 120 power supply 12 for modules and 2 for power supply Vertical 3 Aluminum Black 32 to 122 F 0 to 50 C 80 maximum relative humidity noncondensing 95 maximum relative humidity noncondensing 5 22 H x 18 99 W x 8 85 D 13 26 x 48 23 x 22 48 cm Fits 19 inch ElA standard rack 8 01 lb 3 63 kg with power supply 25 53 Ib 11 58 kg fully populated 14 for modules Vertical 3 Aluminum Black 5 22 H x 18 99 W x 8 85 D 13 26 x 48 23 x 22 48 cm Fits 19 inch ElA standard rack 5 19 Ib 2 35 kg chassis only 25 63 Ib 11 63 kg fully populated C1972M 11 04 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below e Five years on FT FR8000 Series fiber optic products and the following fixed camera models CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and CC3651H 2X Three years on all other fixed camera models including Camclosure Integrated Camera Systems and Genex Series multiplexers server and keyboard Two years on all standard motorized or fixed focal lengt
7. been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shall be placed on the apparatus WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture Installation should be done only by qualified personnel and conform to all local codes Unless the unit is specifically marked as a NEMA Type 3 3R 3S 4 4X 6 or 6P enclosure it is designed for indoor use only and it must not be installed where exposed to rain and moisture Use only installation methods and materials capable of supporting four times the maximum specified load CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other that contained in the operating instructions unless you are qualified to do so Only use replacement parts recommended by Pelco The product and or manual may bear the following marks WARNING This symbol indicates that dangerous voltage constituting a risk of electric CAUTION shock is present within this unit RISK OF ELECTRIC SHOCK A This symbol indicates that there are important operating and maintenance instruc
8. h lenses Two years on Legacy CM6700 CM6800 CM8500 CM9500 CM9700 Series Matrix DF5 and DF8 Series Fixed Dome products Two years on Spectra Esprit and PS20 Scanners including when used in continuous motion applications Two years on Esprit and WW5700 Series window wiper excluding wiper blades Eighteen months on DX Series digital video recorders and NVR300 Series network video recorders and all Endura Series distributed network based video products One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will
9. k mounting MOUNTING A CHASSIS The procedure for mounting an RK5000PS 3U and an RK5000 3U into a rack is exactly the same To mount a chassis follow these steps and refer to Figure 5 1 Insert the chassis into the rack 2 Secure the chassis with the supplied screws and washers Figure 5 Mounting an RK5000PS 3U RK5000 3U into a Rack 10 C1972M 11 04 INSTALLING A MODULE You can install single width or double width modules into the empty slots on the RK5000PS 3U chassis and RK5000 3U chassis To install a module follow these steps and refer to Figure 6 1 Insert the module into an empty slot of the chassis 2 Secure the module by tightening the thumbscrew on the back of the chassis s E a SSO E Figure 6 Module Installation INSTALLING A BLANK MODULE You can use single width or double width blank modules to fill the empty module slots on the chassis To attach a blank module follow these steps and refer to Figure 7 1 Insert the blank module into the empty slot on the chassis 2 Secure the blank module by tightening the thumbscrew on the back of the chassis Figure 7 Blank Module Installation C1972M 11 04 11 Service REMOVING THE POWER BUS You must remove the power bus from the RK5000PS 3U if you want to use the power supplies that are provided with the Fiber modules WARNING Using
10. may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to Pelco 3500 Pelco Way Clovis CA 93612 5699 USA If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco c o Expeditors 473 Eccles Avenue South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 Copyright 2004 Pelco All rights reserved PELCO Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com 1509001 United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East
11. technician for help You may also find helpful the following booklet prepared by the FCC How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington D C 20402 Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules 6 C1972M 11 04 Description The RK5000PS 3U rack mount chassis supports fiber optic modules The chassis has 12 slots and an internal double width power supply You can insert up to 12 single width modules or a combination of single width and double width modules into the slots For redundancy you can use the optional external power supply EPS5000 120 It provides redundant power for up to two fully populated RK5000PS 3U chassis You can mount the chassis which is 3 rack units RU high into an ElA standard 19 inch rack The RK5000 3U chassis has 14 slots and requires an external power supply You can insert up to 14 single width modules or a combination of single width and double width modules into the slots You can mount the chassis which is 3 rack units RU high into an ElA standard 19 inch rack You can use the optional EPS5000 120 external power supply which consists of dual 120 watt hot swappable power supplies to power up to two fully populated RK5000 3U chassis The EPS5000 120 is 1 RU
12. tions in DO NOT OPEN C1972M 11 04 the literature accompanying this unit Regulatory Notices This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV