Home
Paradyne UIM-10/100 User's Manual
Contents
1. NN NET TO NET Me V TECHNOLOGIES Cs nstallation Instructions UI M 10 100 Uplink Interface Module CAUTION Net to Net Technologies strongly recommends the use of proper electrostatic discharge ESD precautions when handling this equipment INSTALLATION 1 Unpack and inspect the equipment The following components should be included e 1 UIM 10 100 e 4 6 Phillips Panhead Internal Locking Screws e 2 6 Phillips Beige Flathead Screws If there is visible damage do not attempt to connect the device contact Customer Support at 1 877 638 2638 001 603 427 0600 for international customers or support nettonet com 2 Install the UI M 10 100 Required tool for installation Phillips screwdriver UIM Installation in an IP DSLAM Affix the UIM to a Multiplexer Uplink Module MUM NOTE The UIM may be attached to a MUM that has already been in service although you must remove the MUM from the IP DSLAM in order to do so Removal of a MUM from an IP DSLAM chassis that is powered up will not affect the operational status of other modules within the chassis it will however disengage the IP DSLAM s upstream network connection a Place the MUM on a flat surface with the circuit board facing up b Selecta porton the MUM for UIM installation either port 1 or 2 may be used Although not required for operational purposes if redundancy is desired two UIMs may be installed on the MUM one in each port 220 0000016 rev01 c
2. Remove the blanking plate from the selected port d Carefully slide the faceplate of the UIM under the lip of the MUM faceplate at the selected port opening such that the UIM circuit board is facedown and the UIM label shows through the port opening with the model name along the right hand edge e Ensure the mounting holes on the UIM are lined up with the corresponding pems on the MUM and the board to board connector key pins are properly aligned f Gently press down with even pressure on all four corners of the UIM until the board to board connector is fully seated g Secure the boards together at the pems with the 4 provided panhead screws h Secure the UIM faceplate to the MUM faceplate using the 2 provided beige flathead Screws CAUTION Blanking plates should be stored for possible future use If a UIM is removed from a MUM it must be replaced with either another UIM or a blanking plate DO NOT INSTALL A MUM WITH AN EMPTY UIM PORT INTO AN IP DSLAM Install the MUM in an IP DSLAM chassis The IPD 12000 is a fourteen slot chassis slots 1 12 are reserved for Access Modules and slots 13 14 are reserved for Multiplexer U plink Modules MU Ms The IPD 4000 is a five slot chassis slots 1 4 are reserved for Access Modules and slot 5 is reserved foraMUM a Align the MUM with the slot module guides of the chosen slot for installation either slot 13 or 14 on the IPD 12000 or slot 5 on the IPD 4000 b Slide the MUM firmly in
3. the Mini DSLAM chassis cover and secure with the original 8 screws CAUTION Blanking plates should be stored for possible future use If a UIM is removed from a Mini DSLAM it must be replaced with either another UIM or a blanking plate DO NOT OPERATE A MINI DSLAM WITH AN EMPTY UIM PORT 3 Establish the Ethernet connection The Ethernet port is 10 100 auto negotiating Net to Net Technologies recommends that you set your hub switch etc to auto negotiate if applicable before making the Ethernet connection Plug the Ethernet cable into the Ethernet RJ45 port on the UIM faceplate Verify the connection solid illumination of the Lnk LED on the UIM faceplate indicates an Ethernet link has been established If the Lnk LED is illuminated but not the 100 LED then a 10 Mbps link has been established If the 100 LED is also illuminated then a 100 Mbps link has been established NOTE For most applications the UIM 10 100 connects to a router or a PC using a straight through Ethernet cable and to a hub or a switch using a crossover Ethernet cable For any other connection combinations you must verify the pinout of the Ethernet device into which you are connecting the UIM 10 100 in order to determine which type of cable is required Ethernet RJ 45 Port Pinout Pin 1 RX Pin5 not used PIN1 Pin 2 Rx Pin 6 Tx Pin3 Tx Pin7 not used Pin 4 not used Pin 8 not used 220 0000016 rev01 Additional I nfo
4. easonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications O peration of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Caution Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Industry Canada Regulatory Compliance I nformation for Class A Equipment This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la Classe A est conforme ala norme NMB 003 du Canada 220 0000016 rev01 European Regulatory Compliance Information for Class A Equipment This Class A product complies with European Norm EN55022 W arning In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures to correct the situation 220 0000016 rev01 Copyright 2001 Net to Net Technologies Inc The Net to Net Logo is a trademark of Net to Net Technologies Inc Worldwide Headquarters http www NetToNet com EMEA Headquarters Net to Net Technologies Contact NetToNet com Net to Net Technologies Victoria House 19 Park Way N
5. ewbury Berkshire RG14 1EE UK 44 0 1635 570950 112 Corporate Drive Suite 1 Portsmouth NH 03801 USA 1 877 638 2638 220 0000016 rev01
6. rmation LED Indicators Additional I nformation If the 100 LED is illuminated the Lnk LED will also be illuminated I ndication Fast Ethernet connection 100 Mbps is established solid green no Fast Ethernet connection no illumination If the 100 LED remains unlit but the Lnk LED is illuminated then a link has been established at 10 Mbps rather than 100 Mbps Act flashing Ethernet activity Traffic is flowing without any problems amber solid amber heavy traffic no illumination no Ethernet activity Either there is no Ethernet link or a link exists but there is no activity Ethernet connection is established solid green If the Lnk LED is illuminated but not the 100 LED then a 10 Mbps link has been established If the 100 LED is also illuminated then a 100 Mbps link has been established no no Ethernet connection illumination The 100 and Act LEDs will remain unlit by default Regulatory Compliance The following regulatory compliance information applies to the UIM 10 100 as installed in a Mini DSLAM chassis or as affixed to a MUM installed in an IP DSLAM chassis FCC Regulatory Compliance Information for Class A Equipment N ote This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide r
7. to the chassis DO NOT USE EXCESS FORCE c Tighten the fastening screws on the MUM faceplate d Verify that the PWR Power LED on the MUM faceplate is illuminated UIM Installation in a Mini DSLAM CAUTION Disconnect all power sources from the Mini DSLAM before installing the UIM a Remove the 8 screws securing the Mini DSLAM chassis and carefully lift off the chassis cover Set the screws aside b Select a porton the Mini DSLAM for UIM installation either port 1 or 2 may be used Although not required for operational purposes if redundancy is desired two UIMs may be installed in the Mini DSLAM one in each port 220 0000016 rev01 c Remove the blanking plate from the selected port d Carefully slide the faceplate of the UIM under the inside lip of the Mini DSLAM atthe selected port opening such that the UIM circuit board is facedown and the UIM label shows through the port opening with the model name along the right hand edge e Ensure the mounting holes on the UIM are lined up with the corresponding pems on the Mini DSLAM board and the board to board connector key pins are properly aligned f Gently press down with even pressure on all four corners of the UIM until the board to board connector is fully seated g Secure the boards together at the pems with the 4 provided panhead screws h Secure the UIM faceplate to the front of the Mini DSLAM chassis using the 2 provided beige flathead screws i Replace
Download Pdf Manuals
Related Search
Related Contents
INSTALLATION AND USE MANUAL Narcotic Gas and Explosive Claroline Manuel d`utilisation 全ページ(2350KB) Samsung R1 Инструкция по использованию Produktübersicht 2011 LED Arc Wave white Panasonic KX-TG6445T telephone Air-Conditioners SLZ-A09, A12, A18AR Documentation - Manu Lorraine Copyright © All rights reserved.