1. the laser spot until it is going back into the hole the laser beam originally came out of Figure 11 Once this is done you will see laser spot spray around the hole You can make certain the laser spot is properly aimed into the hole by slightly adjusting one of the collimation screws to bring the laser spot out of the hole then return it by turning the collimation screw in the opposite direction by the same amount Collimation of the optical system is now complete Go out and enjoy the view The alignment of the mirrors should not need to be adjusted again unless the telescope is handled roughly If you handle the telescope gently during transport then only slight adjustments will need to be made to the mirrors Use the LaserMate Deluxe before each observing session to check and make adjustments to the mirrors as needed Care and Maintenance of Your LaserMate Deluxe Your LaserMate Deluxe is manufactured of the highest quali ty components and is carefully aligned and tested at the factory Like all electronic equipment it should be handled with care If it is dropped or handled roughly it may need to be returned to the factory for re alignment It should not be exposed to water dust heat or sunlight To extend battery life store in a cool dry environment Installing New Batteries When the LaserMate Deluxe s laser beam starts to dim or completely fades it is necessary to install new batteries To Top of Laser Mate Laser Mat
2. INSTRUCTION MANUAL Orion LaserMate Deluxe 5690 Newtonian reflectors perform at their best when their mirrors are accurately aligned While it s not difficult to do collimation can be a chore if you do not have the proper tools The Orion LaserMate Deluxe provides a clear easy way to determine if your telescope s mirrors need adjustment and which adjust ments need to be made With the highly precise alignment provided by the LaserMate Deluxe you ll be enjoying better crisper views in no time The LaserMate Deluxe s laser diode has been precisely aligned within it s housing at the factory Do not drop the LaserMate Deluxe or otherwise roughly handle it or it may need to be returned for re alignment Re alignment is a ser vice that is not covered in the product s limited warranty Also do not remove the label on the LaserMate Deluxe or otherwise attempt to make adjustments to the LaserMate Deluxe s align ments screws doing so will void the terms of the warranty WARNING The LaserMate Deluxe emits laser radiation so it is important not to shine the beam into your or anyone s eye During the collimation procedure it is also important to avoid direct reflections of the laser beam into your eye Rather look only at off axis reflections to determine the position of the laser spot on the mirrors It is safe to view the laser when it is reflected off a surface that will diffuse the light such as the viewing sc
3. e Deluxe s Laser Deluxe s case gt r Top of laser case housing housing a ni bm m a io y f Spring Batteries Figure 12 To install new batteries remove the top of the LaserMate Deluxe s case and the top of the laser housing change batteries you must unthread the top of the LaserMate Deluxe s black aluminum case Figure 12 This will expose the laser housing Be careful not to lose the spring that goes between the top of the case and the laser housing Do not attempt to remove the laser housing from the LaserMate Deluxe unit or your collimator will need to be re aligned at the factory Also removing the laser housing will void your factory warranty It is necessary however to remove the top of the laser housing to access the battery compartment Unthread the top of the laser housing The battery compart ment will now be exposed If you have difficulty unthreading the top of the laser housing slip a straightened paper clip or small rod through the hole in the top of the housing for extra leverage Remove the spent batteries and install two fresh batteries The batteries should be inserted so that the positive end of the batteries face the open end of the battery compart ment After installing new batteries replace the top of the laser housing the spring and the top of the LaserMate Deluxe s case Battery life is approximately three hours so remember to keep the LaserMate Deluxe turned o
4. e rear of the telescope If it isn t loosen the securing thumbscrew on the focuser and rotate the LaserMate Deluxe until it s viewing screen is clearly visible from the rear of the telescope While standing at the rear of the telescope where the primary mirror collimation screws are look up at the viewing screen of the collimator You should see the reflection of the laser somewhere on the view ing screen If you do not see the reflection then a large adjustments to the tilt of the primary mirror will be needed Place a piece of paper in front of the open tube as was done in Figure 8 and note the position of the laser on the paper If the primary mirror is grossly misaligned the laser spot may Ls Laser point Viewing screen Hole Figure 10 The laser spot has been reflected back to the viewing screen of the LaserMate Deluxe The object now is to adjust the tilt of the mirror until the laser point is going back into the hole Viewng screen P Laser hole Figure 11 Once the laser spot is going back into the hole the laser beam originally came out of the telescope is properly collimated be hitting the inside wall of the telescope tube or the focuser drawtube Make large adjustments to the collimation screws as needed to get the laser spot onto the viewing screen Once the laser spot is on the viewing screen Figure 10 you can perform the final collimation Use the primary mirror colli mation screws to move
5. enter of the collimation target on the secondary mirror If it is not you will need to make adjustments to the secondary mirror s position until it is For adjustments perpendicular to the optical axis lengthen and shorten the spider vanes For adjustments parallel to the opti cal axis loosen or tighten the screw centered in the spider s central hub You may also need to adjust the rotation of the secondary mirror relative to the focuser This product complies with 21 CFR 1040 10 and 1040 11 EERE EY J SHS 0d Lisa 2 Al f r Ug One Year Limited Warranty The Orion LaserMate Collimator Deluxe is warranted against defects in materials or workmanship for a period of one year from the date of purchase This warranty is for the benefit of the original retail purchaser only During this warranty period Orion Telescopes amp Binoculars will repair or replace at Orion s option any warranted instrument that proves to be defective provided it is returned postage paid to Orion Warranty Repair 89 Hangar Way Watsonville CA 95076 If the product is not registered proof of purchase such as a copy of the original invoice is required This warranty does not apply if in Orion s judgement the instrument has been abused mishandled or modified nor does it apply to normal wear and tear In addition the war ranty is also void if the laser housing is removed from the unit the product s label is removed or a
6. f paper together Lay the pri mary mirror on the paper and trace its outline with a pencil Figure 1 Next cut out the circle you have just traced with a pair of scissors Fold the paper circle into quarters by folding the circle precisely in half and then folding it in half again Figure 2 Now cut about 1 4 inch off the tip of the paper wedge you have created Figure 3 Unfold the paper and you will find that you have a paper tem plate of your mirror with a hole Figure 1 Trace the outline at the center of the mirror on the paper aa i j gt 4 k Figure 2a 2b Fold the paper circle in half and then in half again Customer Support 800 676 1343 E mail support telescope com Corporate Offices 831 763 7000 P O Box 1815 Santa Cruz CA 95061 IN 218 Rev A 1100 Make sure the template is still clean place the paper template over the surface of the primary mirror Carefully register the tem plate edge with the edge of the mirror Figure 4 Now take one of the supplied collimation tar gets and affix it to the center of the mirrors surface through the hole of the paper template Figure 5 The center of the pri mary mirror is now marked and you can reinstall the primary mir ror in the telescope Figure 6 Figure 3 Cut the tip off the paper wedge Note For mirror cells that use mirror clips to secure the primary mirror in place it is important not to overtighten the mirror clip
7. ff when not in use to maximize battery life Orion has sets of LR 44 bat teries available so call Orion Customer Service at 1 800 447 1001 or visit our website at www telescope com to order a new set Specifications Laser power less than 5mW Laser wavelength 650nm Alignment 3 arcmin Focuser size 1 25 fits 2 with optional 2 to 1 25 adapter Case aluminum black anodized Dimensions 5 875 long x 1 6 diameter Weight 9 8 oz Batteries LR 44 quantity 2 Battery life approximately 3 hours Certification meets all FDA regulations applicable at the time of manufacture Appendix Centering the Secondary Mirror Under the Focuser In order to use the LaserMate Deluxe to center the secondary mirror underneath the focuser you must mark the center of the secondary mirror Do this by first removing the secondary mirror from the telescope and making a paper template the same way you made a template for the primary mirror Use the template and one of the remaining collimation targets to mark the secondary mirror s center Reinstall the secondary mirror once its center has been marked Place the LaserMate Deluxe into the telescope s focuser and turn it on Now peer into the optical tube and look at the pri mary mirror Notice the reflection of the secondary mirror on the primary mirror you will see a bright red spot on the sec ondary mirror where the laser beam is reflecting off it The red spot should be exactly at the c
8. mirror sur faces as long as the beam is not directed into your eye Red laser spot Look down the front of the optical tube Remember to keep your eyes clear of any direct reflections of the beam Notice the red spot on the surface of the primary mirror itself this is the laser beam being reflected from Figure 8 Place a piece of white paper in front of the open tube If you see a laser spot on the paper be careful not to place your eye in that position the secondary mirror off the surface of the primary mirror The red spot should be centered on the primary mirror s surface If it isn t adjustments will be need to be made to the second ary mirror s tilt Figure 9 This is done with the secondary mirror collimation screws usually located on the central hub of the telescope s spider vane assembly f Laser spot on primary Figure 9a 9b To center the red laser spot on the primary mirror you will need to adjust the tilt of the secondary mirror Make adjustments to the telescope s secondary mirror colli mation screws until the reflection of the laser beam is centered on the primary mirror If you have marked your pri mary mirror then the red spot should fall directly in the center of the collimation target Adjusting the Tilt of the Primary Mirror The final collimation adjustment is to adjust the tilt of the pri mary mirror Make certain that the viewing screen on the collimator is facing th
9. ny other attempt is made to change the laser s alignment Factory realign ment is a service not covered by this warranty This warranty gives you specific legal rights and you may also have other rights which vary from state to state For further war ranty information contact Customer Service Department Orion Telescopes amp Binoculars P O Box 1815 Santa Cruz CA 95061 800 676 1343 Orion Telescopes amp Binoculars Post Office Box 1815 Santa Cruz CA 95061 Customer Support Help Line 800 676 1343 Day or Evening
10. reen of the LaserMate Deluxe It is also safe to view the reflection off a mirror surface as long as the beam is not directed into your eye Because of the potential danger from the laser beam store your LaserMate Deluxe out of the reach of children on ORION TELESCOPES amp BINOCULARS Providing Exceptional Consumer Optical Products Since 1975 Marking the Primary Mirror To achieve best accuracy when collimating with the Orion LaserMate Deluxe you will need to mark the center of the primary mirror with one of the supplied collimation targets This will not affect the telescope s performance If you do not wish to mark your primary mirror you will need to judge the primary mirror s center by eye during the collimation proce dure While this is not recommended it is possible to get adequate alignment of the optics without marking the primary mirror s center To accurately locate and mark the mirror s center point you will need to make a paper template First remove the primary mirror from your telescope If you are unsure how to do this consult your telescope s instruction manual If the primary mirror is glued into its cell it is not nec essary to remove it from the cell Handle the mirror by its edges only and be careful not to touch the surface with your fingers Get a clean sheet of paper that is big enough to cover the entire mirror s surface For large diameter mirrors you may need to tape several sheets o
11. s For Orion reflector telescopes tighten the mirror clip anchor screws until just snug and then back off each screw by 1 2 turn Overtightened mirror clips will put stress on the primary mirror s figure and will introduce astigmatism into the optical system as a result Figure 4 Place the template on the mirror surface and carefully register its edge Figure 5 Affix the ring label to the mirror surface through the hole in the template Figure 6 The primary mirror s center is now marked and it is ready to be reinstalled Before You Begin Collimating Using the LaserMate Deluxe Accurate collimation of your telescope s optics using the LaserMate Deluxe will most easily be achieved if you do a rough collimation of the optics with your eye first This is because if the optics are grossly misaligned it may be con fusing to interpret which surfaces the laser is being reflected off of Refer to your telescope s instruction manual for the pro cedure on how to do a rough collimation with your eye Note About Centering the Secondary Mirror Under the Focuser Centering the secondary mirror under the focuser is an adjustment that can be made with the aid of the LaserMate Deluxe but it requires marking the center of the secondary mirror in the same way the center of the primary mirror was marked This is generally undesirable due to the large area of the supplied collimation targets compared to the total area of the
12. secondary mirror Since centering the secondary mirror under the focuser is an adjustment that very rarely if ever needs to be done we recommend simply making this adjust ment by eye Again refer to the collimation instructions in your telescope s manual for the procedure on how to do this If you wish to use the LaserMate Deluxe for centering the secondary mirror under the focuser refer to the appendix section at the end of this manual 9 2 to 1 25 adapter Figure 7a 7b The LaserMate Deluxe fits directly into the drawtube of 1 25 focusers left If you have a 2 focuser you will need to use an optional 2 to 1 25 adapter right Adjusting the Tilt of the Secondary Mirror The first collimation adjustment made with the LaserMate Deluxe will be to adjust the tilt of the secondary mirror Insert the LaserMate Deluxe into your telescope s focuser drawtube Figure 7 Secure it in place with the thumbscrew on the drawtube Then turn the LaserMate Deluxe on by turn ing its thumbscrew clockwise Before looking into the optical tube take a sheet of white paper and place it across the front aperture of the telescope If you see a red laser spot on the sheet of paper then your telescope is considerably out of collimation Figure 8 Take note of the position of the red spot and be careful not to place your eye in that posi tion Remember it is safe to view the reflection of the laser beam off

Download Pdf Manuals

image

Related Search

Orion orion stars orion orionstar orion stars 777 orion lending orion stars login orion advisor login orion stars xyz orion login orion stars vip orion browser orion\u0027s belt orion indemnity orion constellation orion stars online orionstars vip login orion insurance orion180 orion 180 login orion tv orion federal credit union orion fcu orion metallica orion utd orion pharma

Related Contents

Fujifilm FINEPIX A900 DIGITAL CAMERA  humax f4-fta swedish user guide 010705  リアルタイムPCR(SYBR Green I法)実験ガイド  gebruiksaanwijzing magnetron mode d'emploi four solo micro  NOTICE D`UTILISATION SALAD`BAR FROID SB 40 F  User Manual  Brochure Swisscom  DOI  131540-L3 MicroClip XT OM (D6592-0-IT).book - Sicor  取扱説明書  