Home

Omron M7 User's Manual

image

Contents

1. average the same time each day to ensure that the e Stop smoking measurements are genuinely comparable At the e Take regular exercise doctor s surgery nervousness and tension may cause Monitor your blood pressure 200 Upper curve systolic blood pressure Lower curve diastolic blood pressure 150 D E E ine NA eN 50 F T T T T 6 12 18 24 Time of day Example fluctuation within a day male 35 years old 16 Manufacturer OMRON HEALTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN EU representative Ea OMRON HEALTHCARE EUROPE B V Scorpius 33 2132 LR Hoofddorp THE NETHERLANDS www omron healthcare com Production facility Produktionsstatte Productiefaciliteit Site de production Oficina de produccion Stabilimento di produzione OMRON DALIAN CO LTD Dalian CHINA Subsidiary Niederlassung Dochteronderneming Succursale Empresa filial Consociata OMRON HEALTHCARE UK LTD Opal Drive Fox Milne Milton Keynes MK15 ODG U K OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH John Deere Str 81a 68163 Mannheim GERMANY www omron medizintechnik de OMRON SANTE FRANCE SAS 14 rue de Lisbonne 93561 Rosny sous Bois Cedex FRANCE Uniquement pour le march francais OMRON Service Apr s Vente N Vert 0 800 91 43 14 consommateurs omron sante fr www omron sante fr contact Made in China Hergestellt in China Geproduceerd in China
2. to the blood pressure classification by the WHO ISH e Smoking your blood pressure to be higher than in familiar e Excessive alcohol consumption circumstances at home This is known as White Coat e Stress and emotional upset Hypertension e Excessive consumption of salt e Lack of physical exercise Treatment of high blood pressure e Genetic hereditary predisposition If your blood pressure reaches upper values of 140 e Underlying illnesses such as kidney disorders or 160 mmHg and lower values of 90 95 mmHg in endocrine disturbance repeated measurements over several days you should consult your doctor for detailed medical Blood pressure measurement examination You can assist the treatment prescribed Measuring your blood pressure daily enables you to by your doctor in the following ways recognize high blood pressure at an early stage and obtain medical treatment e Loose weight and lower your cholesterol level by reducing the calories and fat in your diet Cut down The oscillometric method of measurement determines on animal fats and eat more fruit and vegetables your blood pressure by measuring the pressure e Reduce the consumption of alcohol fluctuations caused by the pulse waves e Reduce the intake of salt the German League for Combating High Blood Pressure recommends six Since your blood pressure fluctuates within a day see grams of salt per day i e one teaspoon on graphic next page you should always measure it at
3. Fabriqu en Chine Fabricado en China Prodotto in Cina
4. LIN E Digital Automatic Blood Pressure Monitor Instruction manual page 1 Mode d emploi page 49 Gebrauchsanweisung Seite 17 Manuale de instructone pagina 65 Gebruiksaanwijzing pagina 32 Manual de instrucciones pagina 81 IM HEM 780 E 02 10 2011 All for Healthcare 1637848 2E Introduction The OMRON M7 measures your blood pressure and pulse simply and quickly from the arm without the use of an inflation bulb or stethoscope The measurement values are stored in the memory of the OMRON M7 The OMRON M7 includes the standard cuff for arm circumferences ranging from 22 to 42 cm Table of contents 1 How to obtain meaningful blood pressure 4 1 Measurement 7 readings 2 4 2 Read display 9 2 Overview 3 5 Memory 10 3 Preparation 4 5 1 Recall previous values 10 3 1 Insert the batteries 4 5 2 Erase memory 11 3 2 Control functions 4 6 Storage 12 3 3 Set date and time 5 7 Error causes and rectifications 13 3 4 Connect cuff 6 8 Maintenance and spare parts 14 3 5 Fit cuff 6 9 Technical data 14 4 Operation 7 10 General information about blood pressure 15 M7 English 1 How to obtain meaningful blood pressure readings General e This manual contains important information for safe use of the OMRON M7 Follow this manual to prevent wrong measurement values injury and damages e The OMRON M7 is not suitable for measuring the frequency of cardiac pacemakers e Consult your doctor during pregnancy arrhythmia and arterioscler
5. e 00 X Average average value of last 3 measurements displayed Y Pulse heartbeats per minute Z Date time Caution Allow an interval of at least three minutes between two successive measurements 1 Sit comfortably at a table with your feet flat on the 2 Relax your arm and turn your palm upward floor and rest your arm on the table Caution Cuff at heart height during measurement OMRON M7 QO ch OMRON M7 QO shi sense sense T DATE TIME ins wet 38788 O 3 Press on off button Caution Wait for zero and the heart symbol to continue Caution Do not remove cuff during inflation omron M7 QO eli omron M7 QO yl i omron M7 Ne Intelli omron M7 NR uelli jp sense p sense p sense 4P sense ly N A Apr MYA 20 a DATE TIME DATE TIME PULSE SET SET min O 7 O r 4 Press start button and release within 3 seconds Note the unit inflates the cuff If required the unit automatically increases the pressure by 30 mmHg Caution Sit still do not move or speak OMRON M7 U DATE TIME SET Note Wait for automatic deflation OMRON M7 QO 145 intelli OMRON M7 ip sense A U DATE TIME Apei M7 English OMRON M7 WO intelli OMRON M7 AP sense QUA 5 If your systolic blood pressure is known to be more than 220 mmHg press and hold the start button until the monitor inflates 30 or 40 mmHg higher than your es
6. ealth Organisation WHO and the Inter national Society of Hypertension ISH developed the blood pressure classification This classification is based on the blood pressure values measured while sitting on a chair in the outpatient department of a hospital Systolic blood pressure mmHg A 180 160 140 4 0 Normal blood pressure 120 Optimal blood pressure target value Health and blood pressure The incidence of hypertension increases with age In addition a lack of exercise excess body fat and high levels of cholesterol LDL which sticks to the inside in blood vessels reduces elasticity of these vessels Hypertension accelerates arterial sclerosis which can lead to very serious conditions such as stroke and myocardial infarction For these reasons it is very important to know whether the blood pressure is within a healthy range Blood pressure fluctuates from minute to minute throughout the day Therefore it is essential to take regular measurements to help you identify an average blood pressure Symptoms of high blood pressure High blood pressure can go unnoticed for a long time since it does not cause noticeable symptoms The following are all possible causes of abnormally high blood pressure e Overweight e High cholesterol level Severe hypertension Moderate hypertension Mild hypertension Normal systolic value Diastolic blood 80 85 P pressure 90 mmHg 100 110 According
7. not drop the OMRON M7 2 Overview 2 l A Display blood pressure E Start button J Air plug B Display pulse date and time F On off button K Air jack C Memory buttons V A G Cuff L Battery compartment D Date time setting button H Air tube 3 Preparation 3 1 Insert batteries 1 Slide off the battery cover 2 Insert four batteries as indicated in the battery compartment and close compartment Caution Use four identical 1 5V batteries type AA 3 2 Control functions A Display blood pressure B Display pulse date and time C Memory buttons W A D Date time setting button E Start button F On off button 3 3 Set date and time At the first time you set the OMRON M7 the factory settings 0 00 1 1 2003 will be displayed Another time the actual date and time will be displayed Note use the grey coloured button to carry out the instruction OMRON M7 MRON M7 w omro pushi MUA DATETIME PULSE ES Y i 2003 aN SS 2 Press date time setting button for 2 seconds to proceed to year setting Note use a thin stick to press date time settings 1 Press on off button button OMRON M7 NES DIA n uy U oi U MIS patestime ANS O oateine K porh 2004 0 3 Press memory buttons V A to set the year Note if display reaches 2030 it will return to 2003 Note keep memory button down to fast forward Press date time setting button to proceed
8. on Error Cause Abnormal Er memory function Low voltage ty Display empty No data in memory Inexplicable values 8 Maintenance and spare parts Cleaning instruction e Use a soft dry cloth to wipe stains from the OMRON M7 e Use a soft slightly moistened cloth and soap to clean main unit and cuff of the OMRON M7 Caution Do not use petrol thinners or similar solvents Caution Do not wash the cuff e Do not carry out repairs of any kind yourself If a defect occurs consult your OMRON retail outlet or distributor as mentioned on the packaging Calibration e It is recommended to have the OMRON M7 inspected every two years to ensure correct function and accuracy Consult your OMRON retail outlet or OMRON distributor as mentioned on the packaging Batteries weak exhausted AC adapter disconnected Unplugged AC adapter without batteries Wrong working method Rectification Consult your OMRON retail outlet or distributor Fit four new identical 1 5V batteries type AA follow instructions Connect AC adapter correctly follow instructions Fit four new identical 1 5V batteries type AA Follow instructions repeat measurement Replace cuff e Remove the air plug to re use it with a new cuff Replace batteries e Remove the battery out of the battery compartment and insert four new identical 1 5V batteries type AA Spare parts e Due to high company quality standards OMRON considers the main unit as a n
9. on serviceable part because of the need for proper calibration after replacement of high tech components gt Attention Disposal of batteries and the X OMRON M7 should be carried out in A accordance with the national regulations for mmmmmm the disposal of electronic products 9 Technical data Product name Model Display Measurement range Accuracy Inflation Deflation Pressure detection Memory Power supply Battery life Operating temperature Humidity Operating environment Storage temperature Humidity Weight Outer dimensions Accessories Optional parts Note O Manufacturer EU representative M7 English OMRON Digital Automatic Blood Pressure Monitor M7 Digital LCD Pressure 0 299 mmHg Pulse 40 180 minute Pressure 3 mmHg Pulse 5 of display reading Automatic inflation Fuzzy control Automatic air release by controlled air release valve Electrostatic capacity pressure sensor 90 Measurements 4 x 1 5V batteries type AA AC adapter optional part New batteries will last for approximately 300 measurements 10 C to 40 C 30 to max 85 relative humidity Free from excessive vibrations shocks magnetic fields electrical noise etc 20 C to 60 C 10 to max 95 relative humidity Main unit approximately 400 g excluding batteries cuff approximately 130 g Approximately 165 mm W x73 mm H x 110 mm D cuff approximately 150 mm W x 582 mm L arm ci
10. osis as this can influence the measurement e Avoid eating drinking alcohol smoking doing sports and taking a bath before measurement e Be calm and relaxed before and during measurement e You should never change the dose of medicines prescribed by your doctor e Store the OMRON M7 in a dry closed place with a temperature between 20 C and 60 C e Remove the batteries if you do not intend to use the OMRON M7 for 3 months or more Tips for use e Check your blood pressure at least twice a day before breakfast after work e Use the OMRON M7 only for yourself e Measure your blood pressure before taking an antidepressant e Do not discard the air plug e When using the AC adapter keep the batteries in the main unit e Use both the AC adapter and the batteries to extend battery life e Do not measure your blood pressure while you are in a vehicle e Always measure on the same arm e Wrap the cuff around your arm before start of measurement Caution e Only the OMRON M7 cuff can be used on this device Other cuffs must not be attached e Operating temperature between 10 C and 40 C e Operating environment must be free from excessive vibrations shocks electrical noise corrosive gas etc e Stay out of sunlight during measuring e Keep portable phones 5 meters away during measurement e Do not wrap the cuff around any object other than your arm e Do not fold or crush the cuff and the air tube e Do
11. rcumference 22 cm to 42 cm Cuff model HEM CUFF P hard case instruction manual guarantee card blood pressure pass AC adapter extended tube Subject to technical modification without prior notice CE o107 OMRON HEALTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN OMRON HEALTHCARE EUROPE B V Scorpius 33 2132 LR Hoofddorp THE NETHERLANDS Made in China This device fulfils the provisions of the EC directive 93 42 EEC Medical Device Directive This blood pressure monitor is designed according to the European standard EN1060 Non invasive sphygmomanometers Part 1 General Requirements and Part 3 Supplementary requirements for electromechanical blood pressure measuring systems This OMRON product is produced under the strict quality system of OMRON HEALTHCARE Co Ltd Japan The Core component for OMRON blood pressure monitors which is the Pressure Sensor is produced in Japan M7 English 10 General information about blood pressure Blood circulation The blood circulation is responsible for supplying the body with oxygen Blood pressure is the pressure exerted on the arteries The systolic blood pressure value higher pressure or top value represents the blood pressure produced by contraction of the heart muscle The diastolic blood pressure value lower pressure or lower value represents the blood pressure produced by relaxation of the heart muscle Classification of blood pressure The World H
12. s on off button to turn on power Caution Wait for zero and the heart symbol to continue OMRON M7 2 Press memory button W and start button simultaneously to erase memory OMRON M7 a Apuesto OMRON M7 Mu a ma g6 0 85 8 09 DATETIME OMRON M7 QO ashi M7 English Note display shows alternately date and time of measurement Note keep memory buttons V A pushed to fast forward U DATEMI IME Note press memory button V first because the start button will start inflation Caution All stored values will be erased Press on off button to turn off power 11 6 Storage 1 Slightly fold air tube and insert in cuff 2 Put cuff and main unit in storage case Note do not disconnect air tube e Remove the batteries if you do not intend to use the OMRON M7 for 3 months or more e Store the OMRON M7 in the carton in a dry closed place with a temperature between 20 C and 60 C 7 Error causes and rectifications Indication Error Cause Rectification Cee Incorrect inflation Movement Repeat measurement If necessary hold start button to inflate manually Correct Movement sound Follow instructions repeat E measurement Incorrect fastening cuff measurement 3 not possible Operation start button for more than 3 seconds Cuff leaks air Fit new cuff Cuff pressure too high Follow instructions repeat measurement mm 12 7 Error causes and rectifications Indicati
13. timated systolic blood pressure Caution Do not apply more pressure than necessary The monitor will not inflate above the 300 mmHg 4 2 Read display OMRON M7 O Hpi DATE TIME AG 6 00 1 Read values of blood pressure and pulse from displays 7 Tal gt ioe o I E g mm N Co ML 18 00 2 Note values in your personal blood pressure pass M7 English OMRON M7 DIA g mmHg DATE TIME PULSE SET Imin 3 Press on off button to turn off power Note power automatically switches off after 5 minutes 5 Memory 5 1 Recall previous values OMRON M7 NP Intelli AP sense T DATE TIME e e DO 38 88 O 5 W Memory stored measurements displayed 1 Press on off button to turn on power X Average average value of the last 3 measurements Caution Wait for zero and the heart symbol to displayed continue OMRON M7 BS DATE TIME PULSE SET Imin O 2 Press memory button A Note display shows average value of last 3 blood pressures and heartbeats 10 OMRON M7 ue gt g6 OMRON M7 OMRON M7 ACTAIR j L U DATETIME 3 Press memory buttons V A for latest and previous values Press on off button to turn off power 5 2 Erase memory OMRON M7 388 2 855 s 2 188 29 08 ON Intelli 4P sense U DATE TIME SET 1 Pres
14. to date setting ee sense jon M7 Pa ma A Aasi Mpishi SP nels SP sels SME yI DATETIME Vly DATETIME 2 ak START 1 START 8 10 START i 4 pi 4 Use memory buttons W A and date time setting button to set successively month hour and minutes 3 4 Connect cuff P Air jack 1 Insert air plug in air jack 3 5 Fit cuff 1 2 cm wee S A 1 Bare your arm 2 Open the cuff with right hand and cover the cuff Caution Push up your sleeve avoid constricting over your left upper arm the blood flow Caution Do not inflate the cuff when not wrapped around the arm Note keep marked edging on the inside of your elbow Note for right arm use keep the tube under your joint elbow and parallel with your little finger Note keep the tube even with your middle finger 2 3 Hold the cuff wrap it around your arm Caution Be sure the cuff fits closely do not pinch your arm 4 Operation 4 1 Measurement Q Systolic blood pressure in mmHg R Diastolic blood pressure in mmHg I 10 nn q S Heart symbol flash measurement takes place txt light up measurement finished ey GE A ni o ya T Battery exhausted batteries are weak exhausted f UXV U Inflation cuff inflates and measurement starts Y A A e UM V Deflation measurement finished and cuff deflates D u AM nn W Memory stored measurements displayed a t

Download Pdf Manuals

image

Related Search

Related Contents

  Manual de instrucciones  Manual en español CAR MP3  Procedimentos de Pista  Simpli Home 3AXCCRL-05 Instructions / Assembly  Prima Games Splinter Cell Conviction, EN  Betriebs- / Installationsanleitung  BENDIX PRO-GI-01 User's Manual  Peavey KOSMOS V2 User's Manual  MDS931AE-10BT  

Copyright © All rights reserved.