Home

Omron Healthcare RX3 User's Manual

image

Contents

1. for electromechanical blood pressure measuring systems 15 10 General information about blood pressure Blood circulation The blood circulation is responsible for supplying the body with oxygen Blood pressure is the pressure exerted on the arteries The systolic blood pressure value higher pressure or top value represents the blood pressure produced by contraction of the heart muscle The diastolic blood pressure value lower pressure or lower value represents the blood pressure produced by relaxation of the heart muscle Classification of blood pressure The World Health Organisation WHO and the International Society of Hypertension ISH developed the blood pressure classification This classification is based on the blood pressure values measured while sitting on a chair in the outpatient department of a hospital Systolic blood pressure mmHg A Severe hypertension 180 Moderate hypertension 160 Mild hypertension 140 Normal systolic value 1 Normal blood pressure 120 Optimal blood pressure Diastolic target value blood gt pressure 80 85 90 100 110 mmHg According to the blood pressure classification by the WHO ISH Health and blood pressure The incidence of hypertension increases with age In addition a lack of exercise excess body fat and high levels of cholesterol LDL which sticks to the inside in blood vessels reduces elasticity of these vessels Hypertension accelerates arterial scl
2. SE min PULSE min L Memory display 21 values in memory M Average value of the latest 3 measurements displayed 1 Press memory button Note display shows alternately blood pressures and heartbeats 5 2 Recall previous values DIAmmHg DIAmmHg PULSEmin H Q Date time of measurement 1 Press memory button for latest and previous values Press on off button to turn off power Note display shows alternately date blood pressures and time heartbeats 11 omon E RX3 Plus English 5 3 Erase memory DIAmmHg ILSE min 1 Press memory button to turn on 2 Press memory button and power simultaneously on off button to erase memory Caution All stored values will be erased Press on off button to turn off power 6 Storage RX3 Plus English e Store the OMRON RX3 Plus in the hard case in a dry closed place with a temperature between 20 C and 60 C e Remove the batteries if you not intend to use the OMRON RX3 Plus for 3 months or more 7 Faults causes and rectifications Fault Cause Correct reading Movement sound E not possible vibration weak pulse xd Low voltage Batteries K weak exhausted Display empty Inexplicable values Wrong working method 13 Rectification Wait for at least three minutes to repeat measurement Fit two new identical 1 5V alkaline batteries type AAA Follow instructions repeat measurement RX3 Plus English 8 Maintenance and spare parts Cleaning
3. ast after work e Do not measure your blood pressure while you are in a vehicle e Always measure on the same wrist prefer your left wrist for a comfortable use e Wrap the wrist cuff around your wrist before start of measurement Caution e Operating temperature between 10 C and 40 C e Operating environment must be free from excessive vibrations shocks magnetic fields electrical noise etc e Stay out of sunlight during measuring e Keep portable phones 5 meters away during measurement e Do not wrap the cuff other than around your wrist e Do not drop the OMRON RX3 Plus omon e RX3 Plus English 2 Overview A Display E Memory button B Wrist Cuff F On off button C Set button G Battery Compartment D Adjust button omon e RX3 Plus English 3 Preparation 3 1 Insert batteries 1 Open the battery compartment 2 Insert two batteries in the battery compartment Caution Use two identical 1 5V alkaline batteries type AAA 3 Close the battery compartment omon e RX3 Plus English 3 2 Fit wrist cuff Caution Do not press on off button when the wrist cuff is not wrapped around the wrist las 1 Bare your wrist 2 Put the monitor on the inner side Caution Push up your sleeve of your wrist avoid constricting the blood flow 3 Hold the end of the wrist cuff and Note attach the monitor upside wrap it around your wrist down for reliable measurement at Caution Be sure the wrist cuff fi
4. erosis which can lead to very serious conditions such as stroke and myocardial infarction For these reasons it is very important to know whether the blood pressure is within a healthy range Blood pressure fluctuates from minute to minute throughout the day Therefore it is essential to take regular measurements to help you identify an average blood pressure Symptoms of high blood pressure High blood pressure can go unnoticed for a long time since it does not cause noticeable symptoms The following are all possible causes of abnormally high blood pressure e Overweight e High cholesterol level e Smoking e Excessive alcohol consumption e Stress and emotional upset e Excessive consumption of salt e Lack of physical exercise e Genetic hereditary predisposition e Underlying illnesses such as kidney disorders or endocrine disturbance Blood pressure measurement Measuring your blood pressure daily enables you to recognize high blood pressure at an early stage and obtain medical treatment The oscillometric method of measurement determines your blood pressure by measuring the pressure fluctuations caused by the pulse waves Since your blood pressure fluctuates within a day see graphic next page you should always measure it at the same time each day to ensure that the measurements are genuinely comparable At the doctor s surgery nervousness and tension may cause your blood pressure to be higher than in familiar circumstances a
5. instruction e Use a soft slightly moistened cloth to clean the OMRON RX3 Plus and the wrist cuff Caution Do not use petrol thinners or similar solvents Caution Do not wash the wrist cuff e Do not carry out repairs of any kind yourself If a defect occurs consult your OMRON retail outlet or distributor as mentioned on the packaging Calibration e It is recommended to have the OMRON RxX3 Plus inspected every two years to ensure correct function and accuracy Consult your OMRON retail outlet or OMRON distributor as mentioned on the packaging Replace batteries e Remove the battery out of the battery compartment and insert two new identical 1 5V alkaline batteries type AAA Spare parts e Due to high company quality standards OMRON considers the main unit as a non serviceable part because the need for proper calibration after replacement of high tech components e If the cuff needs to be replaced have this done by an authorised expert Consult your OMRON retailer or OMRON distributor as mentioned on the packaging Attention Disposal of batteries and the OMRON RX3 Plus should be carried out in accord ance with the national regulations for the x disposal of electronic products 9 Technical data Product name Model Display Measurement range Accuracy Inflation Deflation Pressure detection Measurement method Memory Power supply Battery life Operating temperature humidity O
6. omon e RX3 Plus English Introduction The OMRON RX3 Plus measures your blood pressure and pulse simply and quickly from the wrist without the use of an inflation bulb or stethoscope The measurement values are stored in the memory of the OMRON RX3 Plus The OMRON RX3 Plus fits wrist circumferences from 13 5 to 19 5 cm snid EXU MM Digital Automatic Blood Pressure Monitor Instruction manual page 1 A Good eae Table of contents N CON OD 10 How to obtain meaningful blood pressure readings Overview Preparation 3 1 Insert batteries 3 2 Fit wrist cuff Operation 4 1 Control functions 4 2 Set date and time 4 3 Measurement 4 4 Read display Memory 5 1 Recall average value 5 2 Recall previous values 5 3 Erase memory Storage Faults causes and rectifications Maintenance and spare parts Technical data General information about blood pressure RX3 Plus English 0 YX Y 001040 1 How to obtain meaningful blood pressure readings General e The OMRON RX3 Plus is not suitable for measuring the frequency of cardiac pacemakers e Consult your doctor during pregnancy arrhythmia and arteriosclerosis e Avoid eating drinking alcohol smoking sport and taking a bath before measurement e Be calm and relaxed before and during measurement e You should never change the dose of medicines prescribed by your doctor Tips for use e Check your blood pressure at least twice a day before breakf
7. perating environment Storage temperature humidity Weight Outer dimensions Wrist circumference Accessories Note e F Type B Manufacturer EU representative OMRON Digital Blood Pressure Monitor RX3 Plus Digital LCD Pressure 0 299 mmHg Pulse 40 180 minute Pressure 3 mmHg Pulse 5 of display reading Automatic by electric pump Automatic rapid deflation system Electrostatic capacity pressure sensor capacitive Oscillometric method 21 Measurements 2 x 1 5V Alkaline batteries AAA New batteries will last for approx 400 measurements 10 C to 40 C 30 to max 85 relative humidity Free from excessive vibrations shocks magnetic fields electrical noise etc 20 C to 60 C 10 to max 95 relative humidity Approx 160 g including batteries Approx 79 mm W x 47 mm H x 71 mm D Approx 13 5 cm to 19 5 cm Instruction manual guarantee card blood pressure pass 2 alkaline batteries storage box Subject to technical modification without prior notice C 0197 OMRON HEALTHCARE Co Ltd 24 Yamanouchi Yamanoshita cho Ukyo ku Kyoto 615 0084 Japan OMRON HEALTHCARE EUROPE B V Kruisweg 577 NL 2132 NA Hoofddorp This device fulfils the provisions of the EC directive 93 42 EEC Medical Device Directive This blood pressure monitor is designed according to the European standard EN1060 Non invasive sphygmomanometers Part 1 General Requirements and Part 3 Supplementary requirements
8. setting Press adjust button to set the current month 4 Press set button to proceed to day setting Press adjust button to set the current day 9 RX3 Plus English DIAmmHg DIAmmHg PULSEN PULSE min 5 Press set button to proceed to 6 Press set button to proceed to hour setting minute setting and Press adjust button to set the press adjust button to set the current hour current minutes DATETIME SET O OND En 7 Press set button to complete setting 8 Press on off button 4 3 Measurement Caution Allow an interval of at least three minutes between two successive measurements 1 Sit comfortably upright with your feet flat on the floor Caution The OMRON RX3 Plus should always be at heart height during measurement RX3 Plus English 2 Press on off button to start measurement The OMRON RX3 Plus measures during inflation Caution Sit still do not move do not speak and do not touch the OMRON RX3 Plus 4 4 Read display PULSEimin PULSEImin 1 Read the values of blood pressure and pulse from the display Note display shows alternately date blood pressures and time heartbeats DIAmmHg PULSEimin 2 Note date time and values in your 3 Press on off button to turn off personal blood pressure pass power 5 Memory 5 1 Recall average value DIAmmHg DIAmmHg JL
9. t home This is known as White Coat Hypertension 17 omron e RX3 Plus English Treatment of high blood pressure 200 Upper curve systolic blood pressure Lower curve diastolic blood pressure Time of day Example fluctuation within a day male 35 years old If your blood pressure reaches upper values of 140 160 mmHg and lower values of 90 95 mmHg in repeated measurements over several days you should consult your doctor for detailed medical examination You can assist the treatment prescribed by your doctor in the following ways e Loose weight and lower your cholesterol level by reducing the calories and fat in your diet Cut down on animal fats and eat more fruit and vegetables e Reduce the consumption of alcohol e Reduce the intake of salt the German League for Combating High Blood Pressure recommends six grams of salt per day i e one teaspoon on average e Stop smoking e Take regular exercise e Monitor your blood pressure
10. ts your right wrist closely do not pinch your arm omon e RX3 Plus English 4 Operation 4 1 Control functions omi sam 30 0 ios o E Bre ESO 99318 pone Lo l C Set button H Date D Adjust button J Systolic blood pressure in E Memory button mmHg F On off button K Diastolic blood pressure in mmHg L Memory display 21 values in memory M Average value of the latest 3 measurements displayed N Monitor blood pressure flash measurement takes place light up finish measurement P Pulse heartbeats per minute Q Time R Inflation wrist cuff inflates and measurement starts S Deflation wrist cuff deflates and measurement finishes T Battery exhausted batteries are weak exhausted 4 2 Set date and time RX3 Plus English Note each time you press adjust button year 2001 2030 month 1 12 day 1 31 hour 0 23 and minutes 0 59 advance by one unit Keep button pressed to advance fast Note use the grey coloured button to carry out the instruction 1 Press set or adjust button omron DATE TIME SET Sinto Syne SHA SSA 7007 mi OO O ON tein PULSE 2 Press set button for 2 seconds Press adjust button to set the current year DIAmmHg DIAmmHg PULSEMmin PULSEmin omron omron S SmmHg se saa SYSmmHg 1 77 OO sae DIAmmHg 3 Press set button to proceed to month