Home
Omron Healthcare HEM-432C User's Manual
Contents
1. with cuff exclude batteries Approximately 4 1 8 w x 3 3 8 h x 4 1 2 d 106mm x 84mm x 116mm Cuff Dimensions Approximately 5 3 4 w x 18 7 8 1 145mm x 480mm Arm Circumference Range Approximately 9 to 13 220mm 320mm Accessories Arm cuff Inflation bulb Instruction manual UPC Code 0 73796 04322 3 NOTE These specifications to improve performance are subject to change without notice 17 18 19 Made in China Manufactured by OMRON HEALTHCARE INC 300 Lakeview Parkway Vernon Hills Illinois 60061 www omronhealthcare com Copyright O 2003 Omron Healthcare Inc 432CINST RevA
2. generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If the product does cause harmful interference to radio or television reception which can be determined by turning the product on and off the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver e Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Cet appareil num rique respecte les limites de bruits radioel ctriques applicables aux appareils num riques de Clase B prescrites dans la norme sur le materiel brouilleur Appareils Num riques ICES 003 dict e par le minister des communications Changes or modifications not expressly approved by the party responsible for complia
3. of the battery compartment as indicated 3 Replace the battery cover NOTE Ifthe Low Battery Indicator appears on the display replace all four batteries Long life alkaline batteries are recommended CARE AND MAINTENANCE To keep your digital blood pressure monitor in the best condition and protect the unit from damage follow the directions listed below Clean the monitor with a soft dry cloth Do not use any abrasive or volatile cleaners Do not attempt to clean the cuff Never immerse the monitor or any components in water Store the monitor in a safe and dry location Do not fold the cuff and tubing tightly Do not subject the monitor to extreme hot or cold temperatures humidity and direct sunlight Avoid subjecting the monitor to strong shocks such as dropping the unit on the floor Remove the batteries if the unit will not be used for three months or longer Always replace all the batteries with new ones at the same time Use the unit consistent with the instruction provided in this manual Use only authorized parts and accessories HOW TO APPLY THE ARM CUFF Pile Material 1 If the cuff is assembled correctly the sewn i hook material will be on the outside of the cuff loop and the metal D ring will not touch your skin Sewn Hook Material 2 Pass the end of the cuff furthest from the tubing through the metal D ring to form a loop The smooth cloth should be on the inside of the c
4. Inflation Blood Pressure Monitor is intended for home use SAVE THESE INSTRUCTIONS 3 IMPORTANT SAFETY NOTES To assure the correct use of the product basic safety measures should always be followed including the precautions listed below M Read all information in the instruction book and any other literature included in the box before using the unit M Contact your physician for specific information about your blood pressure Follow the instructions of your healthcare provider Y Operate the unit only as intended Do not use for any other purpose M The unit is intended for use in measuring blood pressure and pulse rate in adult patient population Do not use on infants M Do not use a cellular phone near the unit It may result in operational failure M Changes or modifications not approved by Omron Healthcare will void the user warranty Do not disassemble or attempt to repair the unit or components KNOW YOUR UNIT Systolic Blood Pressure Display MEMORY Button Diastolic Blood Pressure ON O Button Pulse rate Display d p 7 Arm Cuff V Air Release Button Air ir Tub Inflation Bulb Td ge Air Tube Air Tube Connects to Connects to the air plug the air plug Air Plug Air Plug QUICK REFERENCE GUIDE 1 Avoid eating smoking and exercising for at least 30 minutes before taking a measurement 2 Put your left arm through the cuff loop The bottom of t
5. OMRON MANUAL INFLATION BLOOD PRESSURE MONITOR Model HEM 432C TABLE OF CONTENTS Introduction i 3 Important Safety Notes siriani 4 Know Your ssaa eae iorn EEAS i 5 Quick Reference Guide cccooooooooncnnccconononanononacnnccnnannnannos 6 Battery Installation Replacement 7 Care and Maintenance 8 How To Apply The Arm Cuff_ i 9 10 How To Take A Measurement _ eeren 11 12 How To Use The Memory Function ene 13 Error Indicar S esere renar TESES 14 FCC Statement ica eaae 15 Warraniylafermalioni Sarria ponerte 16 Specifications inoseni teesin erani kinasa 17 Nofes asia sh a E a ee ona 18 19 INTRODUCTION Thank you for purchasing the Omron HEM 432C Manual Inflation Blood Pressure Monitor Fill in for future reference DATE PURCHASED SERIAL NUMBER Staple your purchase receipt here The monitor features an easy to squeeze inflation bulb that allows you to quickly inflate the cuff The measurement reading is clearly displayed on a large digital panel Omron digital blood pressure monitors use the oscillometric method of blood pressure measurement This means the monitor detects your blood s movement through your brachial artery and converts the movements into a digital reading An oscillometric monitor does not need a stethoscope so the monitor is simple to use The Omron HEM 432C Manual
6. Ready To Measure 2 Begin inflating the cuff by rapidly squeezing the inflation bulb until you have reached approximately 40 mmHg higher than your normal systolic reading If your normal systolic blood pressure is unknown inflate the cuff to 180 mmHg 11 HOW TO TAKE A MEASUREMENT 3 Remain still The cuff will begin to deflate automatically 4 As the cuff deflates decreasing numbers Wwe appear on the display The Heart Symbol t Hb Q flashes at every heartbeat Indicated Value Drops y Measuring 5 When measurement is complete the Heart Symbol O stops flashing and your blood pressure and pulse rate are displayed alternately I Bat n B 6 When the Deflation Indication Symbol appears on the display push the Blood Pressure Air Release Button to release any Reading Display air left in the cuff for approx 3 5 sec Pulse Reading Display for approx 2 sec lt NOTE Wait 2 3 minutes before taking another blood pressure measurement Waiting between readings allows the arteries to return to the condition prior to taking the blood pressure measurement Ena Lu o 12 HOW TO USE THE MEMORY FUNCTION This monitor has a memory capable of storing fourteen 14 sets of readings Every time you complete the measurement the monitor automatically stores blood pressure and pulse rate Press the ON Off Button Press the MEMORY Button to recall stored readings while the Heart Symb
7. he cuff should be about 1 2 inch above the elbow The cuff tab should lie over the brachial artery on the inside of the arm 3 Pull the cuff so that it is tightened evenly around your arm Insert one finger under cuff to check fit Press the sewn hook material firmly against the pile side of the cuff Make sure that your skin will not be pinched in the D ring once you inflate the cuff Immediately deflate the cuff and readjust it if skin becomes pinched 4 Sit in a chair with your feet flat on the floor and place your left arm on a table so that the cuff is at the same level as your heart 5 Turn the monitor on and after the Ready To Measure Symbol Q appears next to a zero on the digital panel rapidly squeeze the inflation bulb to inflate the cuff Stop pumping when the numbers on the display are approximately 40 mmHg higher than your normal systolic blood pressure Do not inflate over 280 mmHg 6 The cuff will deflate automatically Remain still throughout the entire reading 7 When measurement is complete the monitor alternately displays your blood pressure pulse rate on the digital panel Press the Air Release Button to remove air in the cuff 8 Wait 2 3 minutes before taking another blood pressure measurement 6 BATTERY INSTALLATION REPLACEMENT 1 Slide the battery cover off in the direction of the arrow 2 Install 4 AA size batteries so positive and negative polarities match the polarities
8. nce could void the user s authority to operate the equipment 15 WARRANTY INFORMATION Limited Warranties Your HEM 432C Manual Blood Pressure Monitor excluding the monitor cuff is warranted to be free from defects in materials and workmanship appearing within 1 year when used in accordance with the instructions provided with the monitor The monitor cuff is warranted to be free from defects in materials and workmanship appearing within one year when the monitor is used in accordance with the instructions provided with the monitor The above warranties extend only to the original retail purchaser We will at our option repair or replace without charge any monitor or monitor cuff covered by the above warranties Repair or replacement is our only responsibility and your only remedy under the above warranties To obtain warranty service ship the monitor and all of the components together with proof of purchase and a note explaining the problem with 5 00 for return shipping and insurance to Omron Healthcare Inc Attn Repair Department 300 Lakeview Parkway Vernon Hills IL 60061 Be sure to include the model number your name and your phone number on the enclosed note and any other correspondence ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE APPLICABLE WRITTEN WARRANTY ABOVE Some states do not all
9. ol O is displayed e When fourteen 14 sets of readings are stored in memory the oldest set will be deleted to store a new set Fire M 1 m m 000 qe E A Pd g gt iv Y a 9 ELH H 67 5 e To delete stored readings press the MEMORY Button and the ON OFF Button simultaneously for 2 seconds AIl readings will be deleted NOTE You can not delete the stored readings partially 13 ERROR INDICATORS Error Symbol Cause Correction Cuff under inflated Movement during Measurement No pulse or blood pressure reading due to very weak artery pulse Wait 2 3 minutes and take another measurement Repeat steps listed under How To Take A Reading Inflate the cuff 40 mmHg higher than the previous inflation value Residual air pressure in cuff Press Air Release Button for 4 5 seconds to release air pressure in cuff Cuff over inflated more than 300 mmHg Carefully read and repeat steps listed under How To Take A Reading Batteries have run down 14 Replace all four AA batteries FCC STATEMENT Note POTENTIAL FOR RADIO TELEVISION INTERFERENCE for U S A only This product has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The product
10. ow limitations on how long an implied warranty lasts so the above limitation may not apply to you OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER INCIDENTAL CONSEQUENTIAL OR INDIRECT COSTS EXPENSES OR DAMAGES Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which may vary from state to state FOR CUSTOMER SERVICE Visit our web site at www omronhealthcare com Call toll free 1 800 634 4350 16 SPECIFICATIONS Model HEM 432C Display LCD Digital Display Measurement Range Pressure 0 to 280 mmHg Pulse 40 180 min Accuracy Calibration Pressure 3mmHg or 2 of reading Pulse 5 of reading Inflation Manual by inflation bulb Deflation Automatic pressure release valve Rapid Air Release Push button valve Pressure Detection Capacitive pressure sensor Measurement Method Pulse Wave Detection Oscillometric method Capacitive pressure sensor Power Source 4 AA batteries Battery Life Approximately 1000 uses Operating Temperature Humidity 50 F to 104 F 10 C to 40 C 30 to 85 RH maximum a Temperature Humidity 4 F to 140 F 20 C to 60 C 10 to 95 RH maximum Console Weight Outer Dimensions Approximately 13 oz 350g
11. uff loop Smooth Cloth 3 Put your left arm through the cuff loop 1 2 inch 12 7 mm The bottom of the cuff should be approximately 1 2 inch above the elbow The cuff tab on the cuff should lie over the brachial artery on the inside of the arm Cuff tab Tube should run down center of arm even with middle finger HOW TO APPLY THE ARM CUFF 4 Pull the cuff so that the top and bottom edges are tightened evenly around your arm 5 When the cuff is positioned correctly press the sewn hook material FIRMLY against the pile side of the cuff 6 Make certain the cuff fits snugly around your arm The cuff should make good contact with your skin 7 Sit in a chair with your feet flat on the floor and place your arm on a table so that the cuff is at the same level as your heart 8 Relax your arm and turn your palm upward 9 Be sure there are no kinks in the air tubing 10 HOW TO TAKE A MEASUREMENT Please read How To Apply The Arm Cuff before taking a reading 1 Press the ON OFF Button a All display symbols appear for about one second nue Rae Initial This is the initial LCD Test LCD Test DE b The display symbols disappear and the Deflation IN Indication Symbol 4 starts to flash Deflation Indication c When the monitor completes the necessary v n preparations before measurement the Heart Symbol LI Q appears next to a zero Wait for the Heart Symbol Q before taking a measurement