Home

Omnitron Systems Technology 2FXM User's Manual

image

Contents

1. SW2 BACKPLANE ENABLE When the DIP switch is in the LEFT DS position factory default the Backplane Port of the 2FXM is isolated from the chassis Ethernet Backplane When the DIP switch is in the RIGHT EN position the Backplane Port is enabled This allows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Link A or B depending on the switch setting SW4 MASTER SLAVE When the 2FXM module is installed in a chassis with an iConverter aaa rectory Default Net k M t Modul A DS Disabled A EN Enabled etwor anagemen odule Backplane Port A Backplane Port A NMM set DIP switch to the LEFT B DS Disabled B EN Enabled M SL position factory default kA PortB _ Backplane Port B The assignment of mastership is swa Reserve Reserve installed management modules To Auto Select Slave Mode Only designate the 2FXM module as the SW5 SW8 Reserved Reserved f master of the chassis set the DIP Figure C DIP Switch Bank 2 switch to the LEFT M SL position and set the DIP switch of the other Illegal Setting Illegal Setting Right Right fllegal Setting allel Figure B DIP Switch Bank 1 installed management modules to the RIGHT SL position to enable Slave Only mode SW5 SW6 SW7 SW8 RESERVED These DIP switches are for factory use only and must always remain in the LEFT position factory default 2 INSTALL MODULE IN CHASSIS AND CONNECT CABL
2. ES a Carefully slide the module into an open slot in the chassis Align the module with the installation guides and ensure that the module is firmly seated against the backplane Secure the module by fastening the front panel thumbscrew push in and turn clockwise to tighten to the chassis front Verify the Pwr LED is ON indicating the chassis is powered b Insert the SFP Fiber transceivers into the Port 1 and Port 2 SFP receptacles on the 2FXM NOTE The release latch of the SFP Fiber transceiver must be in the closed position before insertion d Connect an appropriate multimode or single mode fiber cable to the SFP fiber ports of the installed module It is important to ensure that the transmit TX is attached to the receive side of the device at the other end and the receive RX is attached to the transmit side Single fiber SF media converter models operate in pairs The TX wavelength must match the RX wavelength at the other end and the RX wavelength must match the TX wavelength at the other end NOTE In order to support Remote OAM Management Mode Port 1 of the 2FXM must be connected to the Port 1 on the 2FXM or link partner 3 CONFIGURE MODULE VIA COMMAND LINE INTERFACE To access the Command Line Interface CLI connect the 2FXM RS 232 Console Port to the COM port of a computer equipped with terminal emulation software such as HyperTerminal The Console Port DCE is a mini DIN 6 female connector which can be chang
3. Management Options iConverter Serial Agent Network Management 1 Chassis and Module Management 2 Set Module Name Preferences Management Module Preferences IP and Control Preferences SNMP Preferences Abandon Preference Changes Save Preference Changes Restore Factory Defaults Restart Management Module Other Networking Features Management Module Maintenance 10 Firmware Update 11 Set Date Time IP Address 192 168 1 220 Chassis Number 1 Enter Choice lt H gt elp E lt x gt it gt Figure D Command Line Interface Menu Options The CLI interface allows for the detailed configuration of the module It is recommended to configure the module with an IP address associated with the attached network Also SNMP traphost address should be configured if the module is managed with an SNMP based Management System See the 2FXM User Manual for complete information 4 VERIFY OPERATION LED Function Once the module has been Legend Color Off State installed and configured per On Blinking State A Power Pwr Amber No power On Module has power steps 1 3 verify the module On Power available from i j j H Power Supply Status Chassis Power installed Power Supply X Is operational by viewing the X Amber Supply not installed Blinking No power available LED indicators from installed Power Supply X Port 1 A bii R s H i 5 5 On Fiber link is active hiia LED indicates the ed Link Activity Gre
4. ORT 1 FULL HALF DUPLEX Setting this DIP switch to Half Duplex HDX facilitates a connection that supports Half Duplex Setting this DIP switch to Full Duplex FDX facilitates a connection that supports Full Duplex operation LEFT L RIGHT cl a i Figure A DIP Switch Locations SW3 AND SW4 RESERVED These DIP switches are for factory use only and must always remain in the LEFT factory default position SW5 FIBER PORT 2 FULL HALF DUPLEX Setting this DIP switch to Half Duplex HDX facilitates a connection that supports Half Duplex Setting this DIP switch to Full Duplex FDX facilitates a connection that supports Full Duplex operation SW6 SW7 SW8 LINK MODES The module supports multiple link modes for fault detection and isolation Link Segment should be used for the initial installation of the module Once installed and operational the link mode can be modified Left SW7 Link Mode Selection Factory Default Off PAUS Left Left Left Link Segment LS Pause Disable Pause Enable Factory Default L FDX HDX Left Left Link Propagate LP Fiber Port 1Full Duplex Fiber Port 1Half Duplex Left Left Remote Fault Detect Link pomes oe Ka ie Left Remote Fault Detect Link pma fe Pea DX Symmetrical Fault Detect SFD F HDX Fiber Port 2 Full Duplex Fiber Port 2Half Duplex See Link Mode Selection SW7 DIP SWITCH BANK 2 SW1
5. ed to a DB 9 connector with the included adapter The 2FXM Console Port is a standard asynchronous serial interface Start HyperTerminal and select the correct COM Port in the HyperTerminal Connect To window Set the serial port to the following Bits Per Second 57 600 Stop Bits 1 Data Bits 8 Parity NONE Hardware Flow Control NONE Once connected press lt ENTER gt to bring up a command line prompt on the attached PC A new 2FXM module does not have a password and will skip the Password Entry screen and go straight to the Management Options screen If a password has been set the Password Entry screen will be displayed Type the password and press lt ENTERs gt the 2FXM will respond with the Management Options screen
6. en No Fiber Link Blinking Fiber Data Activity moaule Is receiving power Poni from the chassis Half Full Duplex Green Half Duplex On Full Duplex FDX The Fiber Optic link LEDs _ Chassis Management Chassis Slave On Chassis Master p 3 Blinking ing in OAM indicate the fiber optic MasteSlave Green Mode oo connections have been fPor2 On Fiber link is active established Verify the Link oo Activity Green No Fiber Link Blinking Fiber Data Activity Mode selection is set to Link Por2 Half Full Duplex Green Half Duplex On Full Duplex Segment LS Until a stable link is established leave the Link Mode configured for LS EDX Figure E LED Indicators After a Link presence is established the Link Mode selection can be modified Form 040 08940 002 D 12 07 Omnitron Systems Technology 140 Technology Dr 500 Irvine CA 92618 949 250 6510 tel 949 250 6514 fax www omnitron systems com osr Omnitron Systems Technology Inc iConverter 2FXM Plug in Module QUICK START GUIDE The Omnitron iConverter 2FXM Network Interface Device NID with integrated management provides Fast Ethernet 100BASE FX fiber to fiber media conversion The 2FXM conforms to Ethernet in the First Mile EFM fiber standards to support Fiber to the X FTTX Metropolitan and Enterprise LAN networks Built in Operation Administration and Maintenance OAM functionality enables the 2FXM to operate as a managed demarcati
7. on point at the customer premises and network edge offering service provisioning functions such as Quality of Service and Bandwidth Control rate limiting capabilities i The 2FXM module can be managed using Omnitron s NetOutlook SNMP Management Software 3rd Party SNMP Client Telnet or the Command Line Interface CLI For more information including the complete User Manual on the 2FXM Plug in module access Omnitron s documentation download web page to view all relevant documents http www omnitron systems com downloads php INSTALLATION PROCEDURE 1 Configure DIP Switches 2 Install Module in Chassis and Connect Cables 3 Configure Module via Command Line Interface 4 Verify Operation 1 CONFIGURE DIP SWITCHES DIP SWITCH BANK 1 Switch 1 SW1 PAUSE ENABLE Bank 2 When the Pause Enable DIP switch is in the _ a LEFT Off position factory default the 2FXM Switch 1 E Bank 1 disables the fiber ports ability to send and receive Pause frames during network gwitchg congestion Setting this DIP switch to the RIGHT On position enables the 2FXM to receive Pause frames from its link partner This enables the 2FXM to stop transmitting traffic to its link partner and store incoming frames from the other port in the internal buffer until the congestion clears If the internal buffer of the 2FXM becomes congested it will transmit a Pause frame to its link partner SW2 FIBER P

Download Pdf Manuals

image

Related Search

Related Contents

RAKOFLOOR EPOXI.cdr  IGT G1-5  仕 様 表  地域防災に関する総合情報誌 - 一般財団法人 日本防火・防災協会    Manual_PC30H. Tamaño :  Reber 9000 N  manuale di installazione gpl e metano hpi 07  12V Victor 888 User Manual  BAZZ LU8069AM Installation Guide  

Copyright © All rights reserved.
Failed to retrieve file