1. DIP Switch Local Coax Mode Operation Coax Loopback This DIP switch facilitates the testing of the coax cables When the CLB dip switch is in the right position it sets the coax port to a Local Coax Loopback Mode Figure 4 and the CLB LED is turned ON When in this mode data received at the BNC In is forwarded to the BNC Out and the Fiber Out If no data is received at BNC In an AIS pattern is transmitted out both BNC Out and Fiber Out By returning the DIP switch to the left position the unit resumes normal operation Remote Unit Fiber Out Fiber In BNC Out Fiber In Fiber Out Fig 4 Coax Loopback and DIP Switch Settings Remote Loopback Mode When both the FLB and CLB DIP switches are in the right position they force a remote unit to loop back its fiber and coax ports Figure 5 This facilitates test of the fiber cables and the remote unit without having to physically set DIP switches on the remote unit While in this mode the local unit s BNC is set to a local loopback and its FLB and CLB LEDs are turned ON While in the Remote Loopback Mode the local unit sends a test pattern to the remote unit This pattern forces the remote unit into the loopback mode and is also returned back to the local unit When forced into the Remote Loopback Mode the remote unit s FLB and CLB blink slowly 1Hz When the test pattern is received successfully at the local units Fiber In the
2. osr Omnitron Systems Technology Inc iConverter T3 E3 User Manual OVERVIEW The iConverter T3 E3 managed media converter is a member of the modular iConverter product family The T3 E3 provides standard T3 B3ZS line protocol 44 763Mbps or E3 HDB3 line protocol 34 368Mbps coax to fiber conversion and can be used by telco service providers and enterprise users to connect devices such as PBXs multiplexers routers and video servers via multimode MM single mode SM or single mode single fiber SF fiber Designed to extend the standard T3 E3 Coax network distances over fiber this converter provides protection from environmental noise and effectively increases high speed network reliability The T3 E3 module can be used in any of the iConverter chassis such as the 1 Module 2 Module 5 Module and 19 Module chassis The T3 E3 can be used in a managed or unmanaged fashion When unmanaged it can be installed in an iConverter chassis without a Network Management Module NMM To be managed a NUM module must be installed in the same chassis as the T3 E3 module To read about specific management functionality refer to the NetOutlook user manual T3 E3 section This User Manual covers the models listed in the following table Page 1 The On Board DIP switches facilitate the selection between T3 E3 STS 1 protocols the coax distance fiber and coax port control and the injection of pseudo random data patterns into the
3. Dip Switch Local Fiber Mode Operation Fiber Loopback This DIP switch facilitates the testing of the fiber cables When the FLB dip switch is in the right position it sets the fiber port to a Local Fiber Loopback Mode Figure 3 and the FLB LED is turned ON When in this mode data received at the Fiber In is forwarded to the BNC out and the Fiber Out If no data is received at Fiber In an AIS pattern is transmitted out both BNC Out and Fiber Out By returning the DIP switch to the left position the unit resumes normal operation Remote Unit BNC Out Local Unit FLB CLB FAIS CAIS BNC Out Fig 3 Fiber Loopback and DIP Switch Settings Page 3 T3 E3 SPECIFICATION CHART Model Type T3 E3 ANSI 71 102 11 107 Protocols 71 404 T1 404a T3 ITU G703 E3 G751 0 151 Copper Connectors ETSI EN 300 689 300 686 300 687 RG 59 Coax 75 ohm BNC DS3 380m E3 440m Fiber Connectors SC ST LC MT RJ SFP T3 E3 Sel Coax Build Out Coax En Dis Controls Fiber En Dis AIS to Fiber AIS to Coax PRBS to Coax Loop Bk Coax Loop Bk Fiber Loop Bk Remote Power Fiber Act Coax Act Fiber AIS Det LED Displays Coax AIS Det Coax PRBS Det Fiber Test Fiber Loop Bk Coax Loop Bk Dimensions W 0 85 x D 4 5 x H 2 8 fwognt Pe Standard 0 to 50 C Temperature Wide 40 to 60 C Storage 40 to 80 C Humidity 5 to 95 non condensing MTBF hrs 510 000 Page 8 CLB
4. TST LED blinks rapidly 10Hz Any other data causes slow TST blinking 1Hz If no data is returned to Fiber In the LED is turned OFF Returning both dip switches to the left position causes the local and remote units to resume normal operation Local Unit FLB CLB FAIS CAIS BNC Out Local Unit Remote Unit Fiber Out Fiber In FLB CLB FAIS CAIS Fig 5 Remote Loopback and DIP Switch Settings Page 4 MOUNTING INSTRUCTIONS and CABLE ATTACHMENTS iConverter modules are hot swappable and can be installed into any chassis in the iConverter family 1 Carefully slide the iConverter module into the installation slot aligning the module with the installation guides Ensure that module is firmly seated against the backplane 2 Secure the module by securing the panel fastener screw attached to module to chassis front 3 When using an SFP model 8759 0 insert the SFP Fiber transceiver into the SFP receptacle on the module Note The release latch of the SFP Fiber transceiver must be in the closed position before insertion 4 Connect the fiber cables between the T3 E3 converters The Transmit TX must attach to the Receive RX and the Receive must attach to the Transmit 5 When using a single fiber models you must use mating converters For example if one converter is the model 8750 1 TX 1310nm RX 1550nm the other converter must be model 8751 1 TX 15
5. passed through to Fiber Out Note Some combinations of DIP switch settings are illegal and will be indicated by the Fiber Test TST LED blinking quickly three times followed by a pause Page 6 T3 E3 MODEL NUMBER REFERENCE CHART iConverter T3 E3 Coax Dual Fiber Modules ae ee E Fiber Type Ter se ma te srr po 875 9 0 m Sim era erazo erao sm sokm era eras arasa erara m som erare erasa era iConverter T3 E3 Coax Single Fiber Modules Moa M Tx 1310 nm Tx 1550 nm Rx 1550 nm Rx 1310 nm Type SM SC 8750 1 8751 1 SM SC 8750 2 8751 2 For wide temperature 40 to 60 C add a W to the end of the model number Consult factory for extended temperature 40 to 75 C models When using single fiber SF media converter models the TX wavelength on one end has to match the RX wavelength on the other See SFP data sheet under Fast Ethernet for supported transceiver models Page 2 T3 E3 LED REFERENCE CHART Suneton Color ON Blinking state Legend ied On Power available Fiber Activity Green No valid east blink 10Hz Data Received Act data aye a Amber Fast blink 10Hz AIS Received Local unit asserting Remote Loopback Fast blink 10Hz Test pattern received Fiber Test No Test Slow blink 1 Hz Unexpected pattern Amber Data received Received Special Case Three quick blinks 2Hz and pause 1sec legal dip switch selection ON Local Fiber L
6. 50nm RX 1310nm 6 Attach the BNC cables to the T3 E3 converter and attach the other end of the cables to appropriate network equipment The Transmit must attach to the Receive and the Receive must attach to the Transmit Warning The operating description in this Instruction Manual is for use by qualified personnel only To avoid electrical shock do not perform any servicing of this unit other than that contained in the operating instructions unless you are qualified and certified to do so by Omnitron Systems Technology Inc Warranty This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment TO REGISTER COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM Or you may register your product on the Internet at www omnitron systems com During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective Page 9 FAIS Force AIS to Fiber Force 1 s to Fiber When the FAIS dip switch is in the right position an all ae ones pattern is forced out the Fiber Out port The Coax In FAIS data is discarded and Fiber In data is passed through to CAIS E BNC Out By returning the dip switch to the left position the unit r
7. coax ON OFF E Ts oFF E E3 OFF E STS1 lt 225 E 225 CEN MJ cbis FEN FDIS OFF JJ PRBS Fig 6 Board Mounted DIP Switches T3 E3 and STS 1 DIP Switches Select Protocol When the T3 DIP switch is in the right position the T3 protocol is selected When the E3 DIP switch is in the right position the E3 protocol is selected When the STS 1 DIP switch is in the right position the STS 1 protocol is selected Only one of the three DIP switches may be in the right position at any one time The default setting of the module has no mode selected the module will default to E3 mode with no switches set lt 225 gt 225 Coax Build Out Distance selection When this DIP switch is in the left position a distance of less than 225 ft is selected When in the right position a distance of 225 ft or higher is selected Select the appropriate distance for your application CEN CDIS and FEN FDIS Port Control DIP Switches When both DIP switches are in the left position the ports are enabled When the CEN CDIS is in the right position the coax port is disabled When the FEN FDIS is in the right position the fiber port is disabled PRBS Pseudo Random Pattern Generator Control DIP Switch When in the right position the converter forces Pseudo Random pattern out of the Coax Out port The data received at Fiber In is discarded and the data at Coax In is
8. esumes normal operation CAIS Force AIS to Coax Force 1 s to Coax When the CAIS dip switch is in the right position an all ae ones pattern is forced out the BNC Out port The Fiber In FAIS data is discarded and BNC In data is passed through to ca s Zz Fiber Out By returning the dip switch to the left position the unit resumes normal operation ON BOARD DIP SWITCH SETTINGS Switch Position on Left Function Right Right Function Position Position Function 1 OFF T3 Select default Aa Tr peleaed E3 is selected 2 OFF when T3 and E3 E3 Selected 3 Select default STS 1 are OFF 3 OFF z STS 1 Select default ie Pie ewe 4 Long distan lt 225 Short distance ong distance Coax build out gt 22 equal to or default less than 225ft distance selection more than 225ft 5 CEN Coax port CDIS Coax port Coax port control default enabled disabled OFF 6 FEN Fiber port FDIS Fiber port Fiber port control default enabled disabled OFF Force Ope to OFF Force PRBS 1 to BNC Out BNC Out Note 1 Pseudo Random Bit Sequence PRBS is a data pattern defined by ITU 0 151 spec E3 2423 1 T3 2 15 1 default Normal data PRBS Page 5 For warranty service the product must be sent to an Omnitron desig nated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address u
9. oopback f CLB also ON indicates that the unit is Amber Normal the Local Unit in Remote Loopback Mode Slow blink 1Hz and also CLB in slow blink indicates that the unit is the Remote Unit in Remote Loopback Mode ON Local Coax Loopback f FLB also ON indicates that the unit is Amber Normal the Local Unit in Remote Loopback Mode Slow blink 1Hz and also FLB in slow blink indicates that the unit is the Remote Unit in Remote Loopback Mode es aad Fast blink 10Hz Data Received Coax AIS detected Amber Fast blink 10Hz AIS Received AIS rich Amber Blink 10 Hz PRBS Received PRBS Blink 1 Hz Forcing PRBS onto BNC Out Page 7 FRONT PANEL DIP SWITCH SETTINGS The following DIP switches are located on the front of the T3 E3 converter These switches provide data path control normal operation and loop backs and test patterns all 1 s that assist in installation and fault isolation Fiber Loopback FLB Coax Loopback CLB Fiber AIS FAIS Coax AIS CAIS Fig 1 Front Panel DIP Switches Normal Mode Operation Straight Through The default DIP switch setting all dip switches to the left sets the converter to its Normal Mode and allows data to flow straight through between the BNC and Fiber ports Figure 2 Remote Unit Fiber In BNC Out Local Unit Fiber Out FLB CLB FAIS CAIS ENEN BNC Out Fig 2 Normal Mode and DIP Switch Settings FLB
10. sing Omnitron s standard shipping method Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and or maintenance of the equipment by Buyer Buyer supplied equipment Buyer supplied interfacing unauthorized modifica tions or tampering with equipment including removal of equipment cover by personnel not specifically authorized and certified by Omnitron or mis use or operating outside the environmental specification of the product including but not limited to voltage ambient temperature radiation un usual dust etc or improper site preparation or maintenance No other warranty is expressed or implied Omnitron specifically disclaims the im plied warranties of merchantability and fitness for any particular purpose Exclusive Remedies The remedies provided herein are the Buyers sole and exclusive remedies Omnitron shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any legal theory TECHNICAL SUPPORT For help with this product contact our Technical Support Phone 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 140 Technology Dr 500 Irvine CA 92618 USA E mail support omnitron systems com URL www omnitron systems com Form 040 08740 001D 2 08 Page 10

Download Pdf Manuals

image

Related Search

Related Contents

Netgear WNDAP620 Reference Manual  Kenwood BM250 Convection Oven User Manual  Samsung Galaxy S6 Benutzerhandbuch  Sony KDF-55/60 WF655 Projection Television User Manual  取扱説明書    φ Art.-Nr.: 41.814.43 I.-Nr.: 11021 BG  USB / S / RE - Distribuidora Giorgio  FRED 3 User Manual - JonAcc Ambulance Services  KEH-P6010R KEH  