1.
2. C 0 05 rdg 0 3 C 0 C to 1300 C 0 05 rdg 1 4 F 58 F to 32 F 0 05 rdg 0 6 F 32 F to 2372 F I I I I R S TYPE 0 05 rdg 2 C 0 C to 1767 C 0 05 rdg 4 F 32 F to 3212 F Temperature Coefficient 0 1 times the applicable accuracy specification per C from 0 C to 18 C and 28 C to 50 C 32 F to 64 F and 82 F to 122 F Input Protection 24V dc or 24V ac rms maximum input voltage on any combination of input pins Reading Rate one time per second Input Connector Accepts standard miniature thermocouple connectors flat blades spaced 7 9mm center to center ENVIRONMENTAL Ambient Operating Ranges 0 C to 50 C 32 F to 122 F lt 80 R H Storage Temperature 20 C to 60 C 4 F to 140 F lt 70 R H GENERAL Display 4 digit liquid crystal display LCD with maximum reading of 9999 9 Overload is display Battery Standard 9V battery Battery Life 100 hours typical with carbon zinc battery Auto power off The meter key switch inactive for more than 30 minutes press power key to resume operation Dimensions 192mm H x 91mm W x 52 5mm D Weight 365g OPERATING INSTRUCTIONS D Power Switch The key turns the thermometer on or off In the MIN MAX record mode can not power off must leave MIN MAX record mode then power off C F Selecting the Temperature Scale Readings are dual displayed in either degrees Celsius C or degrees Fa
3. for end of numbers then press overlay ENTER key stored the Hi Limit value enter Lo Limit value set mode Press ENTER key can escape Lo Limit value set mode is displayed in main display Lo Limit value is entered via overlay numbers when you want to get negative values push 0 key for end of numbers then press overlay ENTER key stored the Lo Limit value enter Time set mode 3 Time set mode Press ENTER key can escape Time set mode is displayed in third display Time hours minutes seconds value is entered via overlay numbers then press overlay ENTER key Time start from set time value and exit set mode Relative value Recall display mode Press REL RECALL key to display the Relative set value on second display Press REL RECALL key again to exit this mode Hi Lo Limits value Recall display mode Press Hi Lo RECALL key to display the Hi set Limit value on second display Press Hi Lo RECALL key again to display the Lo Limits set value on second display Press Hi Lo RECALL key again to exit this mode 2 x Button Press xx button to toggle on and off of backlight The backlight will switch off automatically after 60 seconds OPERATOR MAINTENANCE WARNING To avoid possible electrical shock disconnect the thermocouple connectors from the thermometer before removing the cover Battery Replacement Power is supplied by a 9 volt transistor battery The i3 appears on the LCD display when
4. replacement is needed To replace the battery remove the two screws from the back of the meter and lift off the battery cover Remove the battery from battery contacts 10 HH 506 R HH 507 R CALIBRATION PROCEDURE Note The following calibration procedure should perform only by qualified technicians who have access to the items as following Equipment The class of calibrator had better 10 times greater than the measured meter 1 Set the jumper position on J1 position 2 Input DCV 17mV to the T1 after the display is stabilized forward 4 digits then press HOLD key and 0 0 is displayed in main display 3 Input DCV 60mV after the display is stabilized first 4 digits then press HOLD key and 0 1 is displayed in main display 4 Input 0 C K type after the display is stabilized first 4 digits then press HOLD key and 0 2 is displayed in main display 5 Don t push any key and the meter will turn off automatically after 20 seconds After adjustment set the jumper back to J3 position Turn on the meter then input 0 C K type The display reading reads 0 C if the calibration procedure is right DO ees WARRANTY DISCLAIMER BEEN OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase OMEGA Warranty adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and ship
5. 77 6611 FAX 44 161 777 6622 France 9 rue Denis Papin 78190 Trappes Toll Free in England 0800 488 488 Tel 33 130 621 400 FAX 33 130 699 120 e mail sales omega com uk Toll Free in France 0800 4 06342 e mail france omega com It is the policy of OMEGA to comply with all worldwide safety and EMC EMI regulations that apply OMEGA is constantly pursuing certification of its products to the European New Approach Directives OMEGA will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but OMEGA Engineering Inc accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used for patient connected application INTRODUCTION This instrument is a 4 digit compact sized portable digital thermometer designed to use external K J T E R S N type thermocouples as temperature sensor Temperature indication follows Reference Temperature Voltage Tables N I S T Monograph 175 Revised to ITS 90 for K J T E R S N type thermo couples One K type thermocouple are supplied with the thermometer SAFETY INFORMATION Itis recommended that you read the safety and operation instructions before using the thermometer WARNING To avoid electrical shock do not use this instrument when working voltages at the measurement surface over 24V AC or DC
6. OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABILITY The remedies of purchaser set forth herein are exclusive and the total lity of OMEGA with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES m Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER F
7. OMEGA HH507 Digital Thermometer omega com fEOMEGA OMEGAnet On Line Service Internet e mail http www omega com info omega com Servicing North America USA ISO 9001 Certified Canada One Omega Drive Box 4047 976 Bergar Stamford CT 06907 0047 Laval Quebec H7LSA1 Tel 203 359 1660 Tel 514 856 6928 FAX 203 359 7700 FAX 514 856 6886 e mail info omega com e mail info omega com For immediate technical or application assistance USA and Canada Mexico and Latin America Sales Service 1 800 826 6342 1 800 TC OMEGA Tel 95 800 TC OMEGA Customer Service 1 800 622 2378 1 800 622 BEST FAX 95 203 359 7807 Engineering Service 1 800 872 9436 1 800 USA WHEN En Espa ol 203 359 7803 TELEX 996404 EASYLINK 62968934 CABLE OMEGA e mail espanol omega com Servicing Europe Benelux Germany Austria Postbus 8034 1180 LA Amstelveen Daimlerstrasse 26 D 75392 The Netherlands Deckenpfronn Germany Tel 31 20 6418405 FAX 31 20 6434643 Tel 49 07056 3017 FAX 49 07056 8540 Toll Free in Benelux 06 0993344 Toll Free in Germany 0800 82 66342 e mail nl omega com e mail germany omega com Czech Republic United Kingdom ISO 9002 Certified ul Rude armady 1868 733 01 Karvina One Omega Drive Hranice Czech Repubic Riverbend Technology Centre Northbank Irlam Tel 420 69 6311627 FAX 420 69 6311114 Manchester M44 5EX England e mail czech omega com Tel 44 161 7
8. Of Course TEMPERATURE M Thermocouple RTD amp Thermistor Probes Connectors Panels amp Assemblies M Wire Thermocouple RTD amp Thermistor M Calibrators amp Ice Point References M Recorders Controllers amp Process Monitors M Infrared Pyrometers PRESSURE STRAIN AND FORCE M Transducers amp Strain Gauges M Load Cells amp Pressure Gauges M Displacement Transducers M Instrumentation amp Accessories FLOW LEVEL M Rotameters Gas Mass Flowmeters amp Flow Computers M Air Velocity Indicators M Turbine Paddlewheel Systems M Totalizers amp Batch Controllers pH CONDUCTIVITY M pH Electrodes Testers amp Accessories M Benchtop Laboratory Meters M Controllers Calibrators Simulators amp Pumps M Industrial pH amp Conductivity Equipment M 2813 0799 DATA ACQUISITION MI Data Acquisition amp Engineering Software IV Communications Based Acquisition Systems Mi Plug in Cards for Apple IBM amp Compatibles Mi Datalogging Systems M Recorders Printers amp Plotters HEATERS M Heating Cable M Cartridge amp Strip Heaters Mi Immersion amp Band Heaters Mi Flexible Heaters Mi Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL MI Metering amp Control Instrumentation Mi Refractometers M Pumps amp Tubing M Air Soil amp Water Monitors M Industrial Water amp Wastewater Treatment M pH Conductivity amp Dissolved Oxygen Instruments
9. ROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned AR number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the following FOR NON WARRANTY REPAIRS consult OMEGA for information available BEFORE contacting OMEGA current repair charges Have the following information 1 P O number under which the product was PURCHASED available BEFORE contacting OMEGA 2 Model and serial number of the product under warranty and 1 P O number to cover the COST of the repair 3 Repair instructions and or specific problems relative to the 2 Model and serial number of product and product 3 Repair instructions and or specific problems relative to the product OMEGA s policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in technology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC Copyright 1999 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable from in whole or in part without prior written consent of OMEGA ENGINEERING INC Where Do I Find Everything Need for Process Measurement and Contol OMEGA
10. WARNING To avoid damage or burns do not make temperature measurement in microwave ovens CAUTION Repeated sharp flexing can break the thermocouple leads To prolong lead life avoid sharp bends in the leads especially near the connector The A symbol on the instrument indicates that the operator must refer to an explanation in this manual SPECIFICATIONS ELECTRICAL Temperature Scale Celsius or Fahrenheit user selectable Measurement Range Thermocouple Range K TYPE 200 C to 1372 C 328 F to 2501 F J TYPE 210 C to 1050 C 346 F to 1922 F T TYPE 200 C to 400 328 F to 752 E TYPE 210 C to 790 346 F to 1454 F R TYPE 0 to 1767 C 32 to 3212 F S TYPE 0 C to 1767 C 32 F to 32127 N TYPE 50 C to 1300 C 58 F to 2372 Resolution K TYPE 0 1 C 0 1 F 0 F to 700 F 0 2 F on other range J TYPE 0 1 C 0 1 F 0 F to 500 F 0 2 F on other range T TYPE 0 1 C 0 1 F 0 F to 600 F 0 2 F on other range E TYPE 0 1 C 0 1 F 0 F to 450 F 0 2 F on other range R TYPE 17 1 S TYPE 17 1 N TYPE 0 1 C 0 2 F Accuracy Accuracy is specified for operating temperatures over the range of 18 C to 28 C 64 F to 82 F for 1 year not including thermocouple error K J T E TYPE 0 05 rdg 0 3 C 50 C to 1370 C 0 05 rdg 0 7 C 50 C to 210 C 0 05 rdg 0 6 F 58 F to 2498 F 0 05 rdg 1 4 F 58 F to 346 F N TYPE 0 05 rdg 0 7 C 50 C to 0
11. he Relative mode press SET key use set Relative value as a reference value Press REL key again to exit the relative mode In the Relative mode the value can not gt 3000 0 counts shown on the LCD is always the difference between the stored reference and the present reading Hi Lo LIMITS mode only Main display Press Hi Lo LIMITS key to enter the Hi Lo Limits comparative mode LIMIT is displayed In the this mode the automatic power off feature is disabled and REL key HOLD key MAX MIN key are disabled when input temperature value exceed Hi The beeper emits a continuity pulse tone and Hi is displayed and when input temperature value exceed Lo value The beeper emits a discontinuous pulse tone and Lo is displayed Press Hi Lo LIMIT key again to exit the Hi Lo LIMIT mode SET mode Relative value set Time set and Hi Lo Limits value set and Time set 1 Press SET key to enter Relative valuse SET mode Press ENTER key can escape relative valuse set mode REL set mode is displayed in main display Relative value is entered via overlay numbers when you want to get negative values push 0 key for end of numbers then press overlay ENTER key stored the relative value enter Hi Lo Limits value set mode 2 Hi Limit value set mode Press ENTER key can escape Hi Limit value set mode is displayed in main display Hi Limit value is entered via overlay numbers when you want to get negative values push 0 key
12. hrenheit F When the thermometer is turned on it is set to the temperature scale that was in use when the thermometer was last turned off To change the temperature scale press the C F key HOLD Mode only Main display Pressing the HOLD key to enter the Data Hold mode the HOLD annun ciator is displayed When HOLD mode is selected the thermometer held the present readings and stops all further measurements Pressing the HOLD key again to cancel HOLD mode causing thermometer to resume taking measurements In the MIN MAX recording mode press HOLD key to stop the recording Press HOLD key again to resume recording Previously recorded reading are not erased TIMER STOP WATCH Mode Press TIMER STOP W key to enter stop watch mode stop watch is displayed in second display Press start stop key to toggle stop watch starts and stops Time goes up to 99 minutes amp 59 9 seconds In the this mode the automatic power off feature is disabled Pess Clear key to zero the stop watch Press TIMER STOP W key again to exit the stop watch mode K J T E R S N T1 Input Thermocouple Type Select Main display The TYPE key circulating selects the K J T E R S N type thermocouple as input When the thermometer is turned on it is set to the type selected that was in use when the thermometer was last turned off 6 MIN MAX with Time record Mode only Main display Press MIN MAX key to enter the MIN MAX Recording mode displays the Maximum
13. ping time This ensures that OMEGA s customers receive maximum coverage on each product If the unit should malfunction it must be returned to the factory for evaluation OMEGA s Customer Service Department will issue an Authorized Return AR number immediately upon phone or written request Upon examination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of OMEGA s control Components which wear are not warranted including but not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants only that the parts manufactured by it will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS
14. reading with time Minimum reading with time and Average reading stored in record mode In the this mode the automatic power off feature is disabled and D key C F key REL key SET key Hi Lo Limits key and TYPE key are disabled The beeper emits a tone when a new minimum or maximum value is recorded Push MIN MAX key to cycle through the Max Min Avg Present readings If an overload is recorded the averaging function is stopped and average value display The true average of all the reading taken over at least 22 hours preiod can be displayed If 22 hours is exceeded new averages are no longer calculated The last calcalated value is retained as the average reading but the actual minimum and maximum reading will continue to be captured In the this mode press HOLD key to stop the recording of readings all values are frozen press again to restart recording Topreventaccidentalloss of MIN MAX and AVG data inthis mode can only be cancelled by pressing and hold down the MIN MAX key for 2 seconds to exit and erased recorded readings REL Relative mode only Main display Pressing REL key to enter the Relative mode zero the display and store the displayed Reading as a reference value and annunciator REL is displayed Press REL key again to exit the relative mode The relative value can also be entered by the user See SET mode later in this manual When the desired Relative value has been entered press REL key to enter t

Download Pdf Manuals

image

Related Search

Related Contents

LD517拡張用 累積加算表示器  Spider User Manual - Thunder Equipment  KWC Vesuno K.12.VB.92.700A26 User's Manual    EVBUM2174 - NCN8026A Evaluation Board User`s Manual  Smeg KEFV90 cooker hood    取扱説明書はこちら  Et1 enterprise Tabletguia de Inicialização Rápida [Brazil Portuguese  Altra HEC with Reversible Back Panels Assembly Instruction  