Omega Speaker Systems 707 User's Manual
Contents
1. If the inputs of the main and second display are the same then pressing this button will change the thermocouple type for both displays 4 SETUP MODE The following functions can only be use in the setup mode 2 LIMITS Button Hi Lo limit setting Press the LIMITS button to enter the Hi Lo limit setup function The words LIMIT and Hi will be flash on the LCD along with the previous value for the Hi limit Enter the new Hi limit value using the number keys printed in white on the overlay The resolution of Hi Lo limit setup is 1 count The button same button as the ESC can be used to enter negative val ues Press the ENTER button to confirm the new limit You will then be prompted to enter a new Lo limit value Enter the new value and then press enter to finish setup of limits 3 INVT Button Interval time setting To setup the time interval for the log function press the INVT button The indicator INV will blink on the top right of the LCD and the previous interval is displayed Press the number buttons printed in white on the overlay to change the time interval Setting is from left to right of the following format HH MM SS Press the overlay ENTER button to confirm To exit this function press the ESC button HH interval Hour 0 23 MM interval Minute 0 59 SS interval Second 0 59 MAX 23 59 59 MIN 00 00 01 8 APO Button Auto power off time setti
2. Supplied Thermocouple 1 meter 40 type K insulated beaded wire thermocouple Maximum insulation temperature is 482 C 900 F Thermocouple accuracy is 1 1 C or 0 4 of reading whichever is greater from 0 C to 1250 C Wire Communication Protocol 2400 baud rate HH806U 19200 baud rate HH806A External Connections 1 2 1 USB Port 2 DC power JACK 12V gt Be OCO OPERATING INSTRUCTIONS 1 OPERATIONAL MODE There are three operation modes Normal Shift and Setup Mode NORMAL MODE This is the default mode the operating functions for the normal mode are printed on the top of each button in white SHIFT MODE The operating functions for the shift mode are printed in gray on the buttons While in the normal mode press the SHIFT button to switch to shift mode At the lower right corner of the display the word Shift is displayed to indicate shift mode To switch back to normal mode press the SHIFT button again SETUP MODE Press the set button in normal mode to switch to setup mode the indicator SET is shown on the left side of the display To switch back to normal mode press SET button 2 NORMAL MODE The following functions can only be used in the normal mode 1 gt Power Button The D gt button turns the thermometer on or off When the meter is in MAX MIN record mode the power off function is disabled 2 LIMITS Button only Main display The limits f
3. omega com HH806U HH806AU MULTILOGGER THERMOMETER M4502 0707 Shop online at omega com e mail info omega com For latest product manuals omegamanual info eEOmeGA HHe06AU EA APO HoD TiT2 REC AVG MAX MIN ser n f a L REI ne noe ri Te mevuonus crrr GMT AILS BBBB 888680 Main Display Second Display Third Display OPO J k O ae 2 E a gt is READ SET 4 F a O Bk amp _ z oe Us Fe EY _ MAIN SECOND THIRD omega com CEOMEGA OMEGAnet On Line Service omega com Internet e mail info omega com Servicing North America U S A One Omega Drive Box 4047 Stamford CT 06907 0047 ISO 9001 Tel 203 359 1660 Certified e mail info omega com Canada 976 Bergar Laval Quebec H7L 5A1 Canada Tel 514 856 6928 FAX 514 856 6886 e mail info omega ca FAX 203 359 7700 For immediate technical or application assistance US A Sales Service 1 800 826 6342 1 800 TC OMEGA and Customer Service 1 800 622 2378 1 800 622 BEST Canada Engineering Service 1 800 872 9436 1 800 USA WHEN TELEX 996404 EASYLINK 62968934 CABLE OMEGA Mexico En Espa ol 001 203 359 7803 e mail espanol omega com FAX 001 203 359 7807 info ome
4. Calibrators amp Ice Point References t Recorders Controllers amp Process Monitors Infrared Pyrometers PRESSURE STRAIN AND FORCE i Transducers amp Strain Gages Load Cells amp Pressure Gages Displacement Transducers W Instrumentation amp Accessories FLOW LEVEL L Rotameters Gas Mass Flowmeters amp Flow Computers Air Velocity Indicators Turbine Paddlewheel Systems i Totalizers amp Batch Controllers pH CONDUCTIVITY pH Electrodes Testers amp Accessories a Benchtop Laboratory Meters Controllers Calibrators Simulators amp Pumps Industrial pH amp Conductivity Equipment DATA ACQUISITION Data Acquisition amp Engineering Software t Communications Based Acquisition Systems Plug in Cards for Apple IBM amp Compatibles Datalogging Systems i Recorders Printers amp Plotters HEATERS W Heating Cable Cartridge amp Strip Heaters i Immersion amp Band Heaters W Flexible Heaters Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL Metering amp Control Instrumentation E Refractometers 4 Pumps amp Tubing i Air Soil amp Water Monitors i Industrial Water amp Wastewater Treatment pH Conductivity amp Dissolved Oxygen Instruments Made in Taiwan
5. a time Press the larger arrows M or SW to step through the data ten at a time Pressing the overlay ESC button deac tivates the read data function 5 LOG READ Button The read log function works in conjunction with the log function It is used for reading logged data The log function can be activated in the shift mode Press the LOG READ button to activate the log read function the word READ is displayed on the LCD Press the overlay SECOND button to rotate through following display menus T1 T2 GRP and T1 and T2 Dis plays the T1 or T2 saved data GRP Displays the cur rent group number Displays the current location of the read pointer within a selected group The arrow buttons on the overlay are used for scrolling through the data and groups Press the smaller arrows A or WY to step through the logged data or groups one at a time Press the larger arrows or to step through the data or groups ten at a time To navigate the logged data and groups press the overlay SECOND button until GRP appears in the second dis play panel Then select the group using the arrows Press the SECOND button again until the sign is displayed The location of the read pointer in the se lected group will be displayed Use the arrows to scroll through the data Pressing the overlay ESC button deactivates the read data function 7 HOLD Mode only Main display When HOLD mode is se
6. purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned AR number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for shipping cha
7. button printed on the overlay in white will clear all saved and logged data Press ESC button to exit this function without clearing data 7 REL Button Main display The relative value function can be used for comparing the saved reference value with other measurements Press the REL button to store the current measure ment as the reference value and REL should be dis played on the right part of the LCD The next meas urement will display the current value compared to the reference value Press REL button again to clear the reference value and deactivate the relative value meas urement function 8 APO Button Press the APO button to turn the Auto power off function on or off When this function is enabled the indicator APO is shown at the upper left part of the LCD When APO Auto power off is enabled it will automatically turn the thermometer off no button is pressed for a period longer than the set time interval the default time for APO is 5 minutes Press power button to resume operation 10 TYPE Button Main display Press this button to change the type of thermocouple in the main display K J T E R S N If the inputs of the main and second display are the same then pressing this button will change the thermocouple type for both displays 11 TYPE Button Second display Press this button to change the type of thermocouple in the second display K J T E R S N
8. ely upon phone or written request Upon examination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of OMEGA s control Components which wear is not warranted include but are not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants only that the parts manufactured by it will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESS OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABILITY The remedies of
9. ga com mx Servicing Europe Benelux Postbus 8034 1180 LA Amstelveen The Netherlands Tel 31 0 20 3472121 FAX 31 0 20 6434643 Toll Free in Benelux 0800 0993344 e mail sales omegaeng nl Czech Frystatska 184 733 01 Karvina Czech Republic Republic Tel 420 0 59 6311899 FAX 420 0 59 6311114 Toll Free 0800 1 66342 e mail info omegashop cz France 11 rue Jacques Cartier 78280 Guyancourt France Tel 33 0 1 61372900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Germany Daimlerstrasse 26 D 75392 Deckenpfronn Germany Austria Tel 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de United One Omega Drive River Bend Technology Centre Kingdom Northbank Irlam Manchester ISO 9002 M44 5BD United Kingdom Certified Tel 44 0 161 777 6611 FAX 44 0 161 777 6622 Toll Free in United Kingdom 0800 488 488 e mail sales omega co uk It is the policy of OMEGA Engineering Inc to comply with all worldwide safety and EMC EMI regulations that apply OMEGA is constantly pursuing certification of its products to the European New Approach Directives OMEGA will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but OMEGA accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These p
10. lected the thermometer holds the present readings and stops all further measure ments To activate the data hold mode press the HOLD button and HOLD is displayed on the LCD Pressing the HOLD button again cancels the function and the instrument will automatically resume meas urements 8 MIN MAX with Time record Mode only Main display The MIN MAX function records the highest and low est value recorded and it calculates the average read ing and the differences of MAX to MIN Press MIN MAX button to enter the MIN MAX recording mode The beeper emits a tone when a new minimum or maximum measurement is recorded Press the MIN MAX button again to rotate through the current readings MAX The highest measurement recorded MIN The lowest measurement recorded MAX MIN The difference of the highest and the lowest measure ment AVG The average values of the measurements This mode works in conjunction with the hold function pressing the HOLD button will stop the recording and measurements Previously recorded readings are not erased Press HOLD button again to resume recording and measurements To prevent accidental loss of MIN MAX and AVG data the MIN MAX function can only be cancelled by pressing and holding down the MIN MAX key for more then 2 seconds The automatic power off feature and the power C F REL SET Hi Lo Limits TYPE T1 T2 buttons are also disabled 23 10 T1 T2 Button Main display The in
11. ng min 1 minute Use this function to change the time for the auto power off APO function Press the APO button in setup mode and the indicator APO and the current time will flash on the LCD The default time for APO is 5 minutes Press the number button printed in white on the overlay to set the APO time Press the overlay ENTER button to confirm To exit this function without changing the setting press the ESC button MAX 19999 minutes MIN 0001 minutes 9 OFS Button Thermocouple offset ad just When the main display input is T1 and a thermocouple is connected the instrument can adjust the offset of the thermocouple The same can be done for T2 when on the main display In the setup mode press this button to enter the thermocouple Offset Setup Function OFS and the indicator CAL should be displayed on the top right of the LCD and the current setting is also shown Press the number buttons printed in white on the overlay to change the offset of the thermocouple The resolution of the setup is 0 1 Press the button to set a negative value Press the overlay ENTER button to confirm MAX 1999 9 C F 12 TIME Button System time setting To set the system time press the TIME button in the setup mode The third display should show the current date and time with the year flashing Enter the new value from left to right in the following format YY MM DD and HH MM SS Press the number bu
12. put selection button T1 T2 selects the input for the main display T1 thermocouple or T2 thermocou ple Press the T1 T2 button to switch between the two inputs When meter is turned on it is set to the display that was last in use 11 T1 T2 Button Second display The input selection button T1 T2 selects the input for the second display T1 thermocouple or T2 thermo couple Press the T1 T2 button to switch between the two inputs When meter is turned on it is set to the display that was last in use 12 T1 T2 TIME Button Third display The input selection button T1 T2 selects the system time and date or the differential between the two ther mocouples T1 T2 for the third display Press the T1 T2 button to switch the display options When me ter is turned on it is set to the display that was last in use 3 SHIFT MODE The following functions can only be used in the shift mode 2 C F Button Press the C F button to select the temperature scale readings can be displayed in Celsius C or Fahrenheit F When the thermometer is turned on it is set to the temperature scale that was last in use 4 SAVE Button The save function stores the T1 T2 data in a nonvola tile memory Press the SAVE button to save the cur rent data the word SAVE is displayed to indicate the data has been saved The built in memory can store up to 128 data HH806U 256 data HH806AU The data can be read u
13. rges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the following information available BEFORE contacting OMEGA 1 Purchase Order number under FOR NON WARRANTY REPAIRS consult OMEGA for current repair charges Have the following information available BEFORE contacting OMEGA which the product was 1 Purchase Order number to cover PURCHASED the COST of the repair 2 Model and serial number of the 2 Model and serial number of the product under warranty and product and 3 Repair instructions and or specific 3 Repair instructions and or specific problems relative to the product problems relative to the product OMEGA s policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in tech nology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC Copyright 2007 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without the prior written consent of OMEGA ENGINEERING INC Where Do I Find Everything I Need for Process Measurement and Control OMEGA Of Course Shop online at omega com TEMPERATURE 4 Thermocouple RTD amp Thermistor Probes Connectors Panels amp Assemblies W Wire Thermocouple RTD amp Thermistor
14. roducts are not designed for use in and should not be used for human applications INTRODUCTION The instrument is a portable digital thermometer that measures external thermocouples of type K J R S T E N The thermocouples types comply with the N LS T ITS 90 standard reference temperature voltage tables The thermometer features a dual thermocouple input an adjustable T C offset and an USB interface for uploading data to a PC using optional software and cable SAFETY INFORMATION WARNING To avoid electrical shock do not use this instrument when working voltages at the measurement surface over 24V AC or DC WARNING To avoid damage or burns do not make temperature measurement in microwave ovens CAUTION Repeated sharp flexing can break the thermocouple leads To prolong lead life avoid sharp bends in the leads especially near the connector SPECIFICATIONS ELECTRICAL Temperature Scale Celsius or Fahrenheit user selectable Measurement Range K TYPE 0 1 200 C to 1372 C 328 F to 2501 F J TYPE 0 1 210 C to 1200 C 346 F to 2192 F T TYPE 0 1 200 C to 400 C 328 F to 752 F E TYPE 0 1 210 C to 1000 C 346 F to 1832 F R TYPE 1 0 C to 1767 C 32 F to 3212 F S TYPE 1 0 C to 1767 C 32 F to 3212 F N TYPE 0 1 50 C to 1300 C 58 F to 2372 F Based on the ITS 90 temperature standard According to temperature standard ITS 90 Accurac
15. sing the read function in the normal mode 5 LOG Button HH806U The data log function continuously records the data according to a specified time interval The time inter val can be set using the interval setup function INVT in the set up mode Press the LOG button to activate the log function the indicators LOG and MEM will be displayed on the LCD There are 16 groups that are used for storing the log data and each group uses 64 data slots If the current log session exceeds 64 data the log function will automatically use the next group to store the following data A maximum of 1024 data point can be saved in one log session Press the LOG button again to exit the data log function LOG Button HH806AU The data log function continuously records the data according to a specified time interval The time inter val can be set using the interval setup function INVT in the set up mode Press the LOG button to activate the log function the indicators LOG and MEM will be displayed on the LCD There are 16 groups that are used for storing the log data A maximum of 16 000 data point can be saved in one log session Pressing the LOG button again to exit the data log function 6 CLR Button The CLR function clears all the saved and logged data in memory When the CLR button is pressed indicator MEM is displayed and the CLR on upper right of LCD will blink Pressing the ENTER
16. t tons printed in white on the overlay to set the system date and time Press the ENTER button to confirm Exit this function by pressing ESC button OPERATOR MAINTENANCE WARNING To avoid possible electrical shock disconnect the thermocouple connectors from the thermometer before removing the cover Battery Replacement 1 Power is supplied by 4pcs 1 5V AAA SIZE UM 4 RO3 2 The appears on the LCD display when replace ment is needed To replace battery remove screw from back of meter and lift off the battery cover Remove the battery from battery contacts and replace When not in use for long periods remove battery Do not store in locations with high temperatures or high humidity nA BW Cleaning Periodically wipe the case with a damp cloth and deter gent do not use abrasives or solvents Software Operation manual is in the Software disk WARRANTY DISCLAIMER OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase OMEGA s WARRANTY adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that OMEGA s customers receive maximum coverage on each product If the unit malfunctions it must be returned to the factory for evaluation OMEGA s Customer Service Department will issue an Authorized Return AR number immediat
17. unction will alert the user when a meas urement exceeds a specified limit To set the limit val ues refer to limits function in the setup mode Press the LIMITS button to activate the limits function the word LIMIT should be displayed on the LCD When the value of the main display exceeds the Hi limit the word Hi will be displayed and the ther mometer will beep in a pulsed tone If the value of the main display is lower then the Lo limit the word Lo will be displayed and the thermometer will beep in a continuous tone To exit the limits function press the LIMITS button 3 X Button The backlight function is represented by this button Qe Pressing the button will turn on or off the LCD backlight The backlight will turn off automatically af ter 4 SAVE READ Button The read data function works in conjunction with the save function in the shift mode it is used for reading saved data The save function can be activated in shift mode Press the SAVE READ button to read saved data the word READ should be displayed on the LCD To navigate around the save data table press the overlay SECOND button until the sign is dis played on the second display The location of the read pointer within the saved data table will be displayed The arrow buttons on the overlay are used for scrolling through the saved data Press the smaller arrows A or W to step through the data one at
18. y K J T E TYPE 0 05 rdg 0 3 C on 50 C to 1372 C 0 05 rdg 0 7 C on 50 C to 210 C 0 05 rdg 0 6 F on 58 F to 2501 F 0 05 rdg 1 4 F on 58 F to 346 F N TYPE 0 05 rdg 0 8 C on 50 C to 0 C 0 05 rdg 0 4 C on 0 C to 1300 C 0 05 rdg 1 6 F on 58 F to 32 F 0 05 rdg 0 8 F on 32 F to 2372 F R S TYPE 0 05 rdg 2 C on 0 C to 1767 C 0 05 rdg 4 F on 32 F to 3212 F Temperature Coefficient 0 1 times the applicable accuracy specification per C from 0 C to 18 C and 28 C to 50 C 32 F to 64 F and 82 F tol22 F Input Protection 24V de or 24V ac rms maximum input voltage on any combination of input pins Reading Rate 2 5 time per second ENVIRONMENTAL Ambient Operating Ranges 0 C to 50 C 32 F to 122 F lt 80 R H Storage Temperature 20 C to 60 C 4 F to 140 F lt 70 R H GENERAL Display There are three display areas on the HH806 series LCD liquid crystal display The Main and Second displays are 4 4 digits with a maximum reading of 19999 These are used for displaying the value of T1 or T2 The Third display is for the date time or the differential value of T1 to T2 Overload or OL is display Battery 1 5V x 4 PCS SIZE AAA UM 4 R03 Battery Life 120 hours typical with carbon zinc battery Dimensions 160mm H x 83mm W x 38mm D Weight Approx 365g including batteries
Download Pdf Manuals
Related Search
Related Contents
Sangean Electronics Sangean SR-3 User's Manual ROLINE ProSecure II 1500 RM2U - Online UPS, 19" Rack Version Trust Football edition - Sverige Manual de instalación, Manual de usuario atmoMAG Template B60xH105 Statistique « Coordonnées avec erreurs de contrôle » Eye Stretcher EOT-2600 Ezer STEALTH GPS-2 - Racing4fun.at Copyright © All rights reserved.