Olympus AU1000 User's Manual
Contents
1. Grid Display menu However symbols indicating last performed 0 and Next due yellow dates for the month of January will not be displayed in the Grid Display menu from December 1 through December 30 Manual tracking of periodic maintenance must be conducted under these conditions The Periodic Maintenance function is provided as a convenience and therefore in no way impacts system functionality except as described above Inthe Grid Display menu the color of grids for maintenance items should change to yellow when the then current date coincides with the Next maintenance due date However when the Next maintenance due date is February 29 the grids for both February 29 and March 1 will be displayed in yellow In addition printing of the Grid Display using the Report Schedule menu will assign an mark indicating maintenance due date for both February 29 and March 1 Manual tracking of periodic maintenance must be conducted under these conditions The Grid Display function is provided as a convenience and therefore in no way impacts system functionality except as described above DSD 00001 7194 5 4 The Cuvette Status menu displays a yellow color to alert the operator when 8 or more days have elapsed since the last W2 Photocal operation was performed When a W2 Photocal is performed between February 22 and February 29 the yellow color alert will not be display
2. 1999 will result in the date stamp indicating the Last Modified status as the year 1900 e OLYMPUS REPLY and OLYMPUS AU560 Automated Chemistry Analyzers The OLYMPUS REPLY and OLYMPUS AU560 will display a year of 1900 upon transition to January 1 2000 OLYMPUS REPLY systems with operating software versions 2 4 and above and OLYMPUS AU560 systems will require a special software tool to ensure year 2000 compliance Olympus is preparing a special software disk that must be installed in these systems This disk will be provided to you at no charge during the first half of 1999 Customer installation of the special software must be performed upon initial use of the system AFTER 12 00 a m on January 1 2000 No action should be taken prior to 12 00 a m on January 1 2000 Please follow the Year 2000 Conversion Instructions and Test Procedures attached to this Year 2000 Readiness Disclosure Statement Upon complete and correct installation of the special software provided by Olympus OLYMPUS REPLY and OLYMPUS AU560 units will be year 2000 compliant NOTE OLYMPUS DSD 00001 7194 5 REPLY systems with operating software versions below version 2 4 cannot be upgraded using the special software disk SUPPLEMENTAL INFORMATION After December 31 1999 a four digit year must be used to define the date in the OLYMPUS AU560 SET DATE amp ROUND and OLYMPUS REPLY SET DATE amp CAROUSEL menus If existing data indexes have a two dig
3. 1 DIAGNOSTIC DPR 2 DIAGNOSTIC DPR 3 DIAGNOSTIC DPR 4 DIAGNOSTIC DPR 5 MAINTENANCE DPR 6 MAINTENANCE ANL 7 MANUAL MEASURE 1 2 3 WARM 4 5 6 T END 8 22 Select 5 Maintenance DPR and press enter JH 5 MAINTENANCE DPR SELECT No gt 1 DATE MARK 19 2 DATE amp TIME SET 3 CLEANING DRIVE 1 X 3 4 5 6 7 8 23 In the Maintenance DPR menu select 1 Date Mark then press enter 24 Type 20 and press enter 25 Select 2 Date amp Time Set then press enter 26 Enter the Year Month Date Hour Minute and Second you wish within the year 2000 Press the F4 Set key The date and time you entered will be displayed in the upper right corner of the CRT When testing is complete use the following steps to return to the current date 27 From the Operation Menu select F5 DIAG then press the Yes key at the DIAG Yes or No prompt OPERATION MENU SELECT No gt 1 DIAGNOSTIC DPR DSD 00001 7194 5 18 2 DIAGNOSTIC DPR 3 DIAGNOSTIC DPR 4 DIAGNOSTIC DPR 5 MAINTENANCE DPR 6 MAINTENANCE ANL 7 MANUAL MEASURE 1 2 3 WARM 4 5 6 T END 8 28 Select 5 Maintenance DPR and press enter 4 5 MAINTENANCE DPR SELECT No gt 1 DATE MARK 19 2 DATE amp TIME SET 3 CLEANING DRIVE 1 2 3 4 5 6 7 8 29 In the Maintenance DPR menu select 1 Date Mark then press enter 30 Type 19 and press enter 31 Select 2 Date amp Time Set th
4. months years since a consumable was last changed In cases where the unit of time has been defined as Day or Week and February 29 falls between the then current date and the next consumable change date the indicated number of days or weeks since the last consumable change date will be reduced by one unit i e day or week Manual tracking of consumable management must be conducted under these conditions The Consumable Management function is provided as a convenience and therefore in no way impacts system functionality except as described above In the Periodic Maintenance menu the color of maintenance items should change to yellow when the then current date coincides with the Next maintenance due date The color should change to red when the current date exceeds the Next maintenance due date However when the Next maintenance due date is February 29 the Next maintenance due date will be displayed in yellow on March 1 and red on March 2 Manual tracking of periodic maintenance must be conducted under these conditions The Periodic Maintenance function is provided as a convenience and therefore in no way impacts system functionality except as described above Inthe Periodic Maintenance menu the grid corresponding to the date when maintenance was last performed should be marked with an o symbol and the Next maintenance due date should be displayed in yellow in the
5. s Technical Services Department at 800 223 0130 kk Olympus appreciates your continued patronage and support and we look forward to serving you in the future Glenn Mann DSD 00001 7194 5 5 Director of Service Olympus America Inc Diagnostic Systems Division Notice This Statement contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of Olympus America Inc MS DOS is a U S registered trademark of Microsoft Corporation DSD 00001 7194 5 6 YEAR 2000 COMPLIANCE LIMITED WARRANTY OF OLYMPUS AMERICA INC DIAGNOSTIC SYSTEMS DIVISION EXCEPT AS DESCRIBED IN THE YEAR 2000 READINESS DISCLOSURE STATEMENT TO WHICH THIS LIMITED WARRANTY IS ATTACHED Olympus America Inc s Diagnostic Systems Division OAI DSD warrants that it will deliver either a products that do not process date information or b 21st century compliant products that provided that all other products used with the OAI DSD products properly exchange accurate data i will function and operate in accordance with applicable product specifications and logic in the year 2000 ii correctly process date fields and internal date field dependent logic to accurately process and utilize dates beyond December 31 1999 iii store and represent dates in a manner which allows for identification or use of the
6. A gt FIG 6 22 Type GO2000 and press the Enter key on the keyboard see FIG 7 A gt GO2000 FIG 7 23 Wait until the DPR displays the following messages Fig 8 A gt GO2000 Transformation 2000 program for OLYMPUS Data Processor Ver 1 0 Copyright OLYMPUS OPTICAL CO LTD All rights reserved Translation normal end A gt FIG 8 Note If any errors are displayed during steps 21 to 23 refer to the Appendix Error List 24 Remove the MU5907 SPECIAL TOOL for YEAR 2000 floppy disk 25 Move the BOOT switch on the rear side of the DPR from FD to WD When moving the switch please pull out on the switch If the switch is not pulled it cannot be moved FIG 12 9 26 Switch OFF the LOCAL POWER button on the rear side of the DPR FIG12 27 Power on the equipment using the POWER ON switch on the front of the DPR 28 Execute preparation check after program loading completes The Start Condition menu is displayed 29 In the Start Condition menu check the following a Check that the date and time displayed on the top right of the screen is correct b Execute data index change entering for date Check that the date of the new index indicates the correct date DSD 00001 7194 5 6 30 No further action is required Year 2000 Test Procedure Use the following steps to test the change to the year 2000 and then reset to the current date The following items are required to perform this procedure
7. Packard computers If the computer installed with a system is a Hewlett Packard Vectra VL 5 133 or higher clock speed unit no corrective action will be required OLYMPUS AU800 and OLYMPUS AU1000 units which utilize these higher clock speed computers are year 2000 compliant Within the OLYMPUS AU800 and OLYMPUS AU1000 software program on systems utilizing Hewlett Packard computers with slower clock speeds all 386 486 5 75 and 5 120 units the display date data index and printout date_appear to change properly from 12 31 1999 to 01 01 2000 However upon powering off the computer s internal clock will revert to 1980 when the system is next powered on Therefore those Hewlett Packard computers with slower clock speeds will require manual updating of the current date by using the MS DOS DATE command to set the date to 2000 upon initial use AFTER 12 00 a m on January 1 2000 No action should be taken prior to 12 00 a m on January 1 2000 Please follow the Year 2000 Conversion Instructions and Test Procedures attached to this Year 2000 Readiness Disclosure Statement This update MUST be performed on all Hewlett Packard computers with clock speed slower than the Hewlett Packard Vectra VL 5 133 SUPPLEMENTAL INFORMATION The OLYMPUS AU800 and OLYMPUS AU1000 incorporate features that allow data to be stored on floppy disk The OFFLINE FLOPPY DATA OUTPUT menu stores data in a form that can be used offline for function
8. century portion of any date fields without any special processing and iv correctly process dates for leap years OAI DSD s sole responsibility and your exclusive remedy for breach of this Limited Warranty shall be the offer of an update for or the repair or replacement of such products Notwithstanding the foregoing certain products listed on the Year 2000 Readiness Disclosure Statement to which this Limited Warranty is attached may require corrective action to ensure full year 2000 compliance EXCEPT FOR THE LIMITED WARRANTY SET FORTH ABOVE OAI DSD MAKES NO AND DISCLAIMS ALL OTHER REPRESENTATIONS AND WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR CONCERNING ANY PATENTS OR TECHNOLOGY OAI DSD DOES NOT WARRANT THAT SOFTWARE WILL BE ERROR FREE AND OR UNINTERRUPTED MOREOVER OAI DSD DOES NOT WARRANT THE YEAR 2000 COMPLIANCE OF PRODUCTS MANUFACTURED BY THIRD PARTIES OR PRODUCTS NOT SHIPPED FROM OAI DSD INVENTORY OAI DSD DISCLAIMS RESPONSIBILITY AND LIABILITY FOR ENSURING THE YEAR 2000 COMPLIANCE OF INTEGRATED SYSTEMS COMPRISED OF OLYMPUS AND NON OLYMPUS PRODUCTS ALL GUARANTIES WARRANTIES CONDITIONS AND REPRESENTATIONS WHATSOEVER EITHER EXPRESS OR IMPLIED WHETHER ARISING UNDER ANY STATUTE LAW COMMERCIAL USAGE OR OTHERWISE ARE HEREBY EXPRESS EXCLUDED IN NO EVENT SHALL OAI DSD BE LIABLE FOR ANY INDIRECT INCIDENTAL CONSEQUENTIAL OR SPE
9. on the Reply AU560 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Program Floppy Disk 1 3 MU5907 SPECIAL TOOL for YEAR 2000 diskette Confirm that POWER ON switch on the front of the DPR is not illuminated and the analyzer and DPR are off Move the BOOT switch on the rear side of the DPR from WD to FD When moving the switch please pull out on the switch If the switch is not pulled it cannot be moved FIG 12 09 Switch ON the LOCAL POWER switch on the rear side of the DPR FIG 12 Wait until the DPR displays the message Please insert system floppy disk amp hit any key then restart disk mount Confirm that Write Protect is off on the Program Floppy Disk 1 3 insert it into the FD drive and press the Enter J key Wait until the DPR displays the FIG 1 menu Type 7 and the Enter J key on the keyboard Wait until the DPR displays the FIG 2 menu Only Item 1 displays at this time Type S and the Enter J key B and the Enter J key and M and the Enter key on the keyboard Items 2 through 5 will now be displayed on the FIG 2 menu Type 2 and the Enter J key on the keyboard Wait until the DPR displays the FIG 3 menu Type 1 and the Enter J key on the keyboard Type 20 and the Enter J key on the keyboard Press the Menu key The DPR displays the menu shown in FIG 2 Type 1 and the Enter J key on the keyboard The DPR displays the following menu FIG 9 xxx DATE a
10. ANALYZER STATUS 5 SAMPLE LIST 6 DATA MANAGEMENT 7 REPORT 1 2 3 WARM 4 5 DIAG 6 TEND 8 15 From the Operation Menu select F5 DIAG then press the Yes key at the DIAG Yes or No prompt OPERATION MENU SELECT No gt 1 DIAGNOSTIC DPR 2 DIAGNOSTIC DPR 3 DIAGNOSTIC DPR 4 DIAGNOSTIC DPR 5 MAINTENANCE DPR 6 MAINTENANCE ANL 7 MANUAL MEASURE 1 2 3 WARM 4 5 6 T END 8 16 Select 5 Maintenance DPR and press enter 4 5 MAINTENANCE DPR SELECT No gt DSD 00001 7194 5 16 1 DATE MARK 19 2 DATE amp TIME SET 3 CLEANING DRIVE 1 2 3 4 5 6 T 8 17 In the Maintenance DPR menu select 1 Date Mark then press enter 18 Type 20 and press enter 19 The date and time will be properly displayed and updated in the upper right corner of the CRT No further action is required Year 2000 Test Procedure Use the following steps to test for the change to the year 2000 and then reset to the current date 20 Power on the instrument using the Power On switch on the front of the DPR OPERATION MENU SELECT No gt 1 START CONDITION 8 DATA Dies 2 TEST REQUISITION 9QC Ae 3 TEST DATA DISPLAY 4 ANALYZER STATUS 5 SAMPLE LIST 6 DATA MANAGEMENT 7 REPORT 1 2 3 WARM 4 5 DIAG 6 T END 8 21 From the Operation Menu select F5 DIAG then press the Yes key at the DIAG Yes or No prompt OPERATION MENU SELECT No gt DSD 00001 7194 5 17
11. CIAL DAMAGES OF ANY KIND INCLUDING WITHOUT LIMITATION LOSS OF PROFITS OR LOSS OF USE WHETHER OR NOT OAI DSD SHALL BE OR SHOULD BE AWARE OF THE POSSIBILITY OF SUCH POTENTIAL LOSS OR DAMAGE Representations and warranties made by any person including dealers and representatives of OAI DSD which are inconsistent with in conflict with or in addition to the terms of this DSD 00001 7194 5 Limited Warranty shall not be binding upon OAI DSD unless reduced to writing and approved by an expressly authorized officer of Olympus America Inc DSD 00001 7194 5 2 Year 2000 Conversion Instructions and Test Procedure OLYMPUS REPLYand OLYMPUS AU560 Automated Chemistry Analyzers Year 2000 Conversion Instructions Note If you wish to do a year 2000 test of the instrument please see page 5 The following items are required to perform this procedure on the Reply AU560 Program Floppy Disk 1 3 MU5907 SPECIAL TOOL for YEAR 2000 diskette Confirm that POWER ON switch on the front of the DPR is not illuminated and the analyzer and DPR are off 2 Move the BOOT switch on the rear side of the DPR from WD to FD When moving the switch please pull out on the switch If the switch is not pulled it cannot be moved FIG 12 09 3 Switch ON the LOCAL POWER switch on the rear side of the DPR FIG 12 Wait until the DPR displays the message Please insert system floppy disk amp hit any key then restart disk mount 4 Confir
12. December 10 1999 YEAR 2000 READINESS DISCLOSURE STATEMENT TO OLYMPUS CUSTOMERS PRESENTLY USING e OLYMPUS DEMANDO OLYMPUS AU5000 OLYMPUS REPLY OLYMPUS AU560 OLYMPUS AU5200 OLYMPUS AU800 OLYMPUS AU1000 OLYMPUS AU600 OLYMPUS AU640 and OLYMPUS AU400 Automated Chemistry Analyzers e OLYMPUS PK7100 and OLYMPUS PK7200 Automated Microplate Systems e OLYMPUS Aliquotting System OASYS KKK This Year 2000 Readiness Disclosure Statement revises supplements and or restates important information previously disseminated in our Year 2000 Readiness Disclosure Statement dated February 12 1999 the February 1999 Statement Revised and supplemental paragraphs and sections are so noted in this new Year 2000 Readiness Disclosure Statement Those systems described in this Statement as year 2000 compliant are year 2000 compliant in accordance with the attached Year 2000 Compliance Limited Warranty e OLYMPUS DEMAND Automated Chemistry Analyzer REVISED STATUS A four digit year code must be entered in the date Entering a two digit year code in the date may generate an input error and prevent analysis e OLYMPUS AU5000 Automated Chemistry Analyzer REVISED STATUS A four digit year code must be entered in the date Entering a two digit year code in the date may generate an input error and prevent analysis A parameter save load function performed using the Parameter Floppy Disk after December 31
13. K and press the Enter key on the keyboard see FIG 10 Note A space exists between GO2000 and BACK A gt GO2000 BACK FIG 10 100 The DPR will display the following message Fig 11 DSD 00001 7194 5 9 A gt GO2000 BACK Transformation 2000 program for OLYMPUS Data Processor Ver 1 0 Copyright OLYMPUS OPTICAL CO LTD All rights reserved Restore translation normal end A gt FIG 11 Note If any errors are displayed during steps 98 to 100 refer to the Appendix Error List 100 Remove the MU5907 SPECIAL TOOL for YEAR 2000 floppy disk 101 Move the BOOT switch on the rear side of the DPR from FD to WD When moving the switch please pull out on the switch If the switch is not pulled it cannot be moved FIG 12 102 Switch OFF the LOCAL POWER button on the rear side of the DPR FIG12 103 Power on the equipment using the POWER ON switch on the front of the DPR 104 Execute preparation check after program loading completes The Start Condition menu is displayed In the Start Condition menu check the following a Check that the date and time displayed on the top right of the screen is correct b Execute data index change entering for date Check that the date of the new index indicates the correct date 19xx 105 No further action is required DSD 00001 7194 5 10 Rear side of the DPR Appendix Error List Cause and Corrective Action The command typed was no
14. NOT affected Furthermore operation can be easily resumed by re booting the system Disks can be re used however disks containing data stored after December 31 1999 must be initialized using the FLOPPY INITIALIZE menu and using a system date earlier than January 1 2000 An updated version of software will be provided at no charge by June 1 2000 The DATA DOWN LOAD TO FD menu saves data onto a floppy disk in a form that will allow review or editing on the OLYMPUS AU800 and OLYMPUS AU1000 systems This method will function using disks initialized before and after January 1 2000 This is the recommended action for data archive purposes Floppy disk file date stamps will be recorded on the disk as 53 during the year 2000 In addition years subsequent to 2000 will be displayed as 54 55 etc Information stored on the disks will not be affected File date stamps are displayed only when viewed outside the AU800 AU1000 application There will be no software update available to resolve this condition however this condition has no impact on system functionality The impact of the aforementioned conditions on overall system operation is limited and only applies to the operating conditions described above e OLYMPUS AU600 Automated Chemistry Analyzer Much of the information contained in the following paragraph has been gleaned from Hewlett Packard and certain independent test laboratories Olympus has relied
15. e following steps to test for the change to the year 2000 and then reset to the current date 5 Press the Power switch on the analyzer and then press the Q key while the is displayed in the upper left hand corner of the screen The Dos C gt prompt will be displayed 6 Type date and press enter Follow the prompts to enter the date you wish within the year 2000 and press enter 7 Press the Em Stop switch to remove power from the analyzer Press the Power On switch and then the Warm Up switch to restore power and load the program on the analyzer Check that the date you entered is displayed in the upper right corner of the screen When testing is complete use the following steps to return to the current date 8 Perform an end process and wait 15 seconds 9 Press the Power switch on the analyzer and then press the Q key while the is displayed in the upper left hand corner of the screen The Dos C gt prompt will be displayed 10 Type date and press enter Follow the prompts to enter the current date and press enter 11 Press the Em Stop switch to remove power from the analyzer Press the Power On switch and then the Warm Up switch to restore power and load the program on the analyzer Check that the current date is displayed in the upper right corner of the screen No further action is required DSD 00001 7194 5 12 Year 2000 Conversion Instructions and Test Procedure OLYMPUS AU5200 Automated Chemistr
16. e power from the analyzer Press the Power On switch and then the Warm Up switch to restore power and load the program on the analyzer Check that the date you entered is displayed in the upper right corner of the screen When testing is complete use the following steps to return to the current date 32 Perform an end process and wait 15 seconds 33 Press the Power switch on the analyzer and then press the Q key while the is displayed in the upper left hand corner of the screen The Dos C gt prompt will be displayed 34 Type date and press enter Follow the prompts to enter the current date and press enter 35 Press the Em Stop switch to remove power from the analyzer Press the Power On switch and then the Warm Up switch to restore power and load the program on the analyzer Check that the current date is displayed in the upper right corner of the screen No further action is required DSD 00001 7194 5 20
17. ed until 9 days following the date of such W2 Photocal operation The scheduling of W2 Photocal operations during this period must be manually tracked The printout generated by the Report Schedule menu should include the o and symbols for the Executed maintenance date and the Next maintenance due date respectively However from December 31 through January 30 the printout generated by the Report Schedule menu will not include the o and symbols for the portion of the month of January after the then current date Information prior to and including the then current date will be printed Manual tracking of periodic maintenance must be conducted under these conditions The Report Schedule function is provided as a convenience and therefore in no way impacts system functionality except as described above The print function for maintenance activities will indicate a status of 31 days in all months Please disregard maintenance marks for all dates that do not exist e g February 30 April 31 This print function is provided as a convenience and therefore in no way impacts system functionality except as described above An updated version of software will be provided at no charge by June 1 2000 e OLYMPUS PK7100 Automated Microplate System REVISED STATUS When a single digit 0 9 or two digit 00 09 year is entered in the date dates contained in pr
18. en press enter 32 Enter the current Year Month Date Hour Minute and Second Press the F4 Set key The date and time you entered will be displayed in the upper right corner of the CRT No further action is required DSD 00001 7194 5 19 Year 2000 Conversion Instructions and Test Procedure OLYMPUS AU800 Automated Chemistry Analyzer Year 2000 Conversion Instructions 25 Press the Power switch on the analyzer and then press the Q key while the is displayed in the upper left hand corner of the screen The Dos C gt prompt will be displayed 26 Type date and press enter Follow the prompts to enter the correct date within the year 2000 and press enter 27 Press the Em Stop switch to remove power from the analyzer 28 Press the Power On switch and then the Warm Up switch to restore power and load the program on the analyzer Check that the correct date is displayed in the upper right corner of the screen No further action is required Year 2000 Test Procedure Use the following steps to test for the change to the year 2000 and then reset to the current date 29 Press the Power switch on the analyzer and then press the Q key while the is displayed in the upper left hand corner of the screen The Dos C gt prompt will be displayed 30 Type date and press enter Follow the prompts to enter the date you wish within the year 2000 and press enter 31 Press the Em Stop switch to remov
19. inted reports and on monitor screens will indicate a one digit year 0 to 9 for the 2000 to 2009 year period A four digit year 2000 2009 must be entered in the date e OLYMPUS PK7200 Automated Microplate Systems The OLYMPUS PK7200 program only updates the last two digits of the displayed year Therefore the OLYMPUS PK7200 will display 01 01 1900 upon transition to January 1 2000 Manual resetting of the date and time utilizing the Maintenance software menu of the system will be required To ensure year 2000 compliance the date and time fields MUST be updated upon initial use of the system AFTER 12 00 A M on January 1 2000 No action should be taken prior to 12 00 a m on January 1 2000 Please follow the Year 2000 Conversion Instructions and Test Procedures attached to this Year 2000 Readiness Disclosure Statement e OLYMPUS Aliquotting System OASYS The OLYMPUS Aliquotting System OASYS uses the date stamp for internal error log display only The year will be displayed as 00 upon transition to January 1 2000 The date is not associated with any instrument functions other than the error log display The OASYS is year 2000 compliant KKK Included with this Year 2000 Readiness Disclosure Statement are Year 2000 Conversion Instructions and Test Procedure documents for the REPLY AU560 AU600 AU800 AU1000 AU5200 and PK7200 systems If you have any questions please do not hesitate to contact Olympus
20. it year entry they must be searched separately from those data indexes having a four digit year entry e OLYMPUS AU5200 Automated Chemistry Analyzer To ensure the year 2000 compliance of the OLYMPUS AU5200 the system MUST be powered off by performing an END PROCESS prior to midnight on December 31 1999 The system must remain off during the brief transition from December 31 1999 to January 1 2000 If this process is followed completely and correctly the date field will be correctly displayed as 01 01 2000 upon initial power on after 12 00 a m on January 1 2000 no further corrective action will be necessary and the system will be year 2000 compliant However if the OLYMPUS AU5200 is not powered off during the transition from December 31 1999 to January 1 2000 the date displayed in the upper right hand corner of the monitor will be incorrectly listed as 01 01 1900 on January 1 2000 In such event you must follow the steps set forth in the attached Year 2000 Conversion Instructions and Test Procedures to correct the displayed date e OLYMPUS AU800 and OLYMPUS AU1000 Automated Chemistry Analyzers Much of the information contained in the following paragraph has been gleaned from Hewlett Packard and certain independent test laboratories Olympus has relied upon the information provided by Hewlett Packard and these independent test laboratories The OLYMPUS AU800 and OLYMPUS AU1000 utilize a number of different Hewlett
21. m that Write Protect is off on the Program Floppy Disk 1 3 insert it into the FD drive and press the Enter J key 5 Wait until the DPR displays the following menu FIG 1 RE SYSTEM MAINTENANCE SELECT No gt 1 INITIALIZE MEDIA 2 PASSWORD SET 3 COMMUNICATION 4 MAINTENANCE 5 HISTORY 6 COPY FILES 7 SYSTEM UP FIG 1 6 Type 7 and the Enter key on the keyboard 7 Wait until the DPR displays the following menu FIG 2 Only Item 1 displays at this time DSD 00001 7194 5 SYSTEM UP SELECT No gt 1 DATE amp TIME SET 2 SYSTEM PARAMETERS 3 OPTION UNIT 4 DATA FILE INITIALIZE 5 PARAMETER INITIALIZE 3 4 5 6 As 8 PRINT FIG 2 8 Type S and the Enter J key B and the Enter J key and M and the Enter key on the keyboard Items 2 through 5 will now be displayed on the above menu FIG 2 9 Type 2 and the Enter key on the keyboard Wait until the DPR displays the following menu FIG 3 x SYSTEM PARAMETER SELECT No gt 1 DATE MARK 2 AREA AMERICA 3 CYCLE 60 4 PERIOD ROUND 1 9 SEC ROUND 2 9 SEC ROUND 3 9 SEC ROUND 4 9 SEC 5 INQUIRY ROUTINE amp EMERGENCY BARCODE ACAL SEQUENCE QC SEQUENCE 6 SYSTEM PASSWORD 3 4 5 6 8 PRINT FIG 3 10 Type 1 and the Enter key on the keyboard 11 Type 20 and the Enter key on the keyboard 12 Press the OPS Menu key on the keyboard The DPR displays the menu shown in FIG 1 13 Type 6 and
22. mp TIME SET SELECT No gt 6 SECOND 4 SET 5 FIG 9 Type 1 and the Enter J key on the keyboard Type 00 for the year and the Enter key on the keyboard DSD 00001 7194 5 7 46 47 48 49 50 S51 52 53 54 55 56 57 58 59 60 61 62 Type 2 and the Enter J key on the keyboard Type 01 for the month and the Enter key on the keyboard Type 3 and the Enter J key on the keyboard Type 01 for the day and the Enter J key on the keyboard Press F4 Set to set the date and time The date and time displayed in the upper right hand corner of the screen will reflect your changes Press the OPS Menu key on the keyboard The DPR displays the menu shown in FIG 1 Type 6 and the Enter J key on the keyboard Wait until the DPR displays the FIG 4 menu Type 1 and the Enter J key on the keyboard Wait until the DPR displays the FIG 5 menu Type 2 and the Enter J key on the keyboard Wait until file number 2 M510SYS FIL has been copied Press the OPS Menu on the keyboard The DPR displays the menu shown in FIG 1 Press the function key F8 Exit on the keyboard Wait until the DPR displays the message BE SURE TO SET BOOT SWITCH ON WD SIDE AND PRESS RESET SWITCH Remove the Program Floppy Disk 1 3 Switch OFF the LOCAL POWER switch on the rear side of the DPR FIG12 Wait 10 seconds and switch ON the LOCAL POWER button on the rear side of the DPR FIG12 Wait until the DPR displa
23. nt date 69 70 71 72 Perform an End Process on the instrument Move the BOOT switch on the rear side of the DPR from WD to FD When moving the switch please pull out on the switch If the switch is not pulled it cannot be moved FIG 12 09 Switch ON the LOCAL POWER switch on the rear side of the DPR FIG 12 Wait until the DPR displays the message Please insert system floppy disk amp hit any key then restart disk mount Confirm that Write Protect is off on the Program Floppy Disk 1 3 insert it into the FD drive and press the Enter J key DSD 00001 7194 5 8 73 Wait until the DPR displays the FIG 1 menu 74 Type 7 and the Enter J key on the keyboard 75 Wait until the DPR displays the FIG 2 menu Only Item 1 displays at this time 76 Type S and the Enter J key B and the Enter key and M and the Enter J key on the keyboard Items 2 through 5 will now be displayed on the FIG 2 menu 77 Type 2 and the Enter key on the keyboard Wait until the DPR displays the FIG 3 menu 78 Type 1 and the Enter key on the keyboard 79 Type 19 and the Enter key on the keyboard 80 Press the Menu key The DPR displays the menu shown in FIG 2 81 Type 1 and the Enter key on the keyboard The DPR displays the FIG 9 menu 82 Type 1 and the Enter key on the keyboard 83 Type the current year and the Enter key on the keyboard 84 Type 2 and the Enter key on the keyboard 85 Type
24. rformed on all Hewlett Packard computers with clock speed slower than the Hewlett Packard Vectra VL 5 133 SUPPLEMENTAL INFORMATION DSD 00001 7194 5 3 Offline Output and Data floppy disk file date stamps will be recorded on the disks as 53 during the year 2000 In addition years subsequent to 2000 will be displayed as 54 55 etc Information stored on the disks will not be affected File date stamps are displayed only when viewed outside the AU600 application This condition has no impact on system functionality In the Periodic Maintenance menu the Next date indicating the next scheduled due date for a maintenance item will be displayed one day late when February 29 2000 falls between the Executed date i e the date periodic maintenance was last performed and the Next date i e the calculated date the next periodic maintenance is due Manual tracking of periodic maintenance must be conducted under these conditions The Periodic Maintenance function is provided as a convenience and therefore in no way impacts system functionality except as described above Integrity of patient data is not affected by the aforementioned conditions An updated version of software will be provided at no charge by June 1 2000 e OLYMPUS AU400 and OLYMPUS AU640 Automated Chemistry Analyzers REVISED STATUS The Consumable Management menu displays an interval of time i e days weeks
25. s such as spreadsheet applications When performing the OFFLINE FLOPPY DATA OUTPUT function using a Data Floppy Disk initialized after January 1 2000 program execution will be interrupted As a result program status information may appear on the PC monitor Patient data residing in the system hard drive is not affected and operation can be easily resumed by re booting the system It is recommended that a sufficient quantity of Data Floppy Disks be initialized prior to January 1 2000 in order to support offline floppy data output for a period of one month In the event DSD 00001 7194 5 2 that there are no initialized Data Floppy Disks available upon transition to January 1 2000 the system date can be set to a date prior to January 1 2000 in the AUXILIARY CURRENT DATE AND TIME menu Disks can then be initialized using the FLOPPY INITIALIZE menu Should this procedure be required the date must be returned to the then current date and time prior to analysis in the AUXILIARY CURRENT DATE AND TIME menu In addition pre initialized Data Floppy Disks will be available from Olympus after January 15 2000 An updated version of software will be provided at no charge by June 1 2000 Re using a Data Floppy Disk containing data stored after December 31 1999 will result in an interruption in program execution As a result program status information may appear on the PC monitor Patient data residing in the system hard drive is
26. t correct Re type command 2 or 4 Patch file B INITOO TSK not The file on the DPR might be corrupted found Contact Technical Support This system is already translated The date on the system is already converted to the year 20xx Power the DPR on again If the to 20xx year does not display as 20xx contact Technical Support Patch strings 1900 not foundin The conversion to the year 2000 has failed this file B INITO0 TSK Contact Technical Support GO2000 was not executed Execute GO2000 before 20xx yet executing GO2000 BACK 5 Can t create new file The conversion to the year 2000 has failed B INITO0 20 Contact Technical Support DSD 00001 7194 5 11 Year 2000 Conversion Instructions and Test Procedure OLYMPUS AU1000 Automated Chemistry Analyzer Year 2000 Conversion Instructions 1 Press the Power switch on the analyzer and then press the Q key while the is displayed in the upper left hand corner of the screen The Dos C gt prompt will be displayed 2 Type date and press enter Follow the prompts to enter the correct date within the year 2000 and press enter 3 Press the Em Stop switch to remove power from the analyzer 4 Press the Power On switch and then the Warm Up switch to restore power and load the program on the analyzer Check that the correct date is displayed in the upper right corner of the screen No further action is required Year 2000 Test Procedure Use th
27. the Enter J key on the keyboard Wait until the DPR displays the following menu FIG 4 DSD 00001 7194 5 4 COPY FILES SELECT No gt 1 FILE COPY 2 FILE CREATE 8 PRINT FIG 4 14 Type 1 and the Enter J key on the keyboard Wait until the DPR displays the menu shown in FIG 5 x PILE COPY SELECT No gt DEV FILE NAME DEV FILE NAME DEV FILE NAME 1 MKP SYS 2 M510S YS FIL 1 ALL 2 FROM 3 BACK 4 NEXT 5 6 CHANGE 7 8 PRINT FIG 5 15 Type 2 and the Enter key on the keyboard Wait until file number 2 M510SYS FIL has been copied 16 Press the OPS Menu on the keyboard The DPR displays the menu shown in FIG 1 17 Press the function key F8 Exit on the keyboard Wait until the DPR displays the message BE SURE TO SET BOOT SWITCH ON WD SIDE AND PRESS RESET SWITCH 18 Remove the Program Floppy Disk 1 3 19 Switch OFF the LOCAL POWER switch on the rear side of the DPR FIG12 20 Wait 10 seconds and switch ON the LOCAL POWER button on the rear side of the DPR FIG12 Wait until the DPR displays the message Please insert system floppy disk amp hit any key then restart disk mount 21 Insert the MU5907 SPECIAL TOOL for YEAR 2000 floppy disk into the FD drive and press the Enter key on the keyboard Wait until the DPR displays the following messages FIG 6 DSD 00001 7194 5 5 CP M 86 Version 1 0 Segment Address F000 Last Offset 317F CP M86 Version 1 0
28. the current month and the Enter key on the keyboard 86 Type 3 and the Enter key on the keyboard 87 Type the current day and the Enter key on the keyboard 88 Press F4 Set to set the date and time The date and time displayed in the upper right hand corner of the screen will reflect your changes 89 Press the OPS Menu key on the keyboard The DPR displays the menu shown in FIG 1 90 Type 6 and the Enter J key on the keyboard Wait until the DPR displays the FIG 4 menu 91 Type 1 and the Enter J key on the keyboard Wait until the DPR displays the FIG 5 menu 92 Type 2 and the Enter key on the keyboard Wait until file number 2 M510SYS FIL has been copied 93 Press the OPS Menu on the keyboard The DPR displays the menu shown in FIG 1 94 Press the function key F8 Exit on the keyboard Wait until the DPR displays the message BE SURE TO SET BOOT SWITCH ON WD SIDE AND PRESS RESET SWITCH 95 Remove the Program Floppy Disk 1 3 96 Switch OFF the LOCAL POWER switch on the rear side of the DPR FIG12 97 Wait 10 seconds and switch ON the LOCAL POWER button on the rear side of the DPR FIG12 Wait until the DPR displays the message Please insert system floppy disk amp hit any key then restart disk mount 98 Insert the MU5907 SPECIAL TOOL for YEAR 2000 floppy disk into the FD drive and press the Enter key on the keyboard Wait until the DPR displays the message from FIG 6 99 Type GO2000 BAC
29. thin the year 2000 and press enter 19 Press the Em Stop switch to remove power from the analyzer Press the Reset switch and then the Power switch to restore power and load the program on the analyzer Check that the date you entered is displayed in the upper right corner of the screen When testing is complete use the following steps to return to the current date 20 Perform an end process and wait 15 seconds 21 Press the Power switch on the analyzer and then press the Q key while the is displayed in the upper left hand corner of the screen The System Maintenance Menu will be displayed 22 Type 14 and press enter to select option 14 Go to DOS 23 Type date and press enter Follow the prompts to enter the current date and press enter DSD 00001 7194 5 14 24 Press the Em Stop switch to remove power from the analyzer Press the Reset switch and then the Power switch to restore power and load the program on the analyzer Check that the current date is displayed in the upper right corner of the screen No further action is required DSD 00001 7194 5 15 Year 2000 Conversion Instructions and Test Procedure OLYMPUS PK7200 Automated Microplate System Year 2000 Conversion Instructions 14 Power on the instrument using the Power On switch on the front of the DPR OPERATION MENU SELECT No gt 1 START CONDITION 8 DATA 21 ceive 2 TEST REQUISITION 9 QC PEES 3 TEST DATA DISPLAY 4
30. upon the information provided by Hewlett Packard and these independent test laboratories The OLYMPUS AU600 utilizes a number of different Hewlett Packard personal computers If the computer installed with a system is a Hewlett Packard Vectra VL 5 133 or higher clock speed unit no corrective action will be required OLYMPUS AU600 units which utilize these higher clock speed computers are year 2000 compliant Within the OLYMPUS AU600 software program on systems utilizing Hewlett Packard computers with slower clock speeds 5 75 and 5 120 units the display date with two digit year code located in the upper right hand portion of the screen changes from 12 31 99 to 01 01 00 The date display is for convenience purposes only and does not affect the system s functionality However the data index and printout dates within the system program software contain a four digit year code Consequently upon powering off the computer s internal clock will revert to 1980 when the system is next powered on Therefore those Hewlett Packard computers with slower clock speeds will require manual updating of the current date by using the MS DOS DATE command to set the date to 2000 upon initial use AFTER 12 00 a m on January 1 2000 No action should be taken prior to 12 00 a m on January 1 2000 Please follow the Year 2000 Conversion Instructions and Test_Procedures attached to this Year 2000 Readiness Disclosure Statement This update MUST be pe
31. y Analyzer Year 2000 Conversion Instructions 1 From the Ops Menu select 21 Auxilliary Menu then select 8 Current Date and Time 2 In this menu press the Enter key for the Year Month Day Hour Minute and Day of Week This menu will have the updated date already 3 Press the Yes key at the All Ok Yes No gt __ prompt The display will now be correct No further action is required Year 2000 Test Procedure Use the following steps to test for the change to the year 2000 and then reset to the current date 4 From the Ops Menu select 21 Auxilliary Menu then select 8 Current Date and Time 5 In this menu type 1999 for the Year 12 for the Month 31 for the Day 23 for the Hour 59 for the Minute and Friday for the Day of Week 6 Press the Yes key at the All Ok Yes No gt __ prompt 7 The date in the upper right hand corner of the screen will switch to 01 01 1900 8 Select 8 Current Date and Time 9 In this menu press the Enter key for the Year Month Day Hour Minute and Day of Week This menu will have the updated date already 10 Press the Yes key at the All Ok Yes No gt __ prompt The display will now be correct When testing is complete use the following steps to return to the current date 11 Select 8 Current Date and Time 12 In this menu type the current date time hour minute and day of the week for the Year Month Day Hour Minute and Day of Week prompts 13 Press the Yes ke
32. y at the All Ok Yes No gt __ prompt Confirm the correct date and time is displayed in the upper right hand corner of the display No further action is required DSD 00001 7194 5 13 Year 2000 Conversion Instructions and Test Procedure OLYMPUS AU600 Automated Chemistry Analyzer Year 2000 Conversion Instructions 12 Press the Power switch on the analyzer and then press the Q key while the is displayed in the upper left hand corner of the screen The System Maintenance Menu will be displayed 13 Type 14 and press enter to select option 14 Go to DOS 14 Type date and press enter Follow the prompts to enter the correct date within the year 2000 and press enter 15 Press the Em Stop switch to remove power from the analyzer Press the Reset switch and then the Power switch to restore power and load the program on the analyzer Check that the correct date is displayed in the upper right corner of the screen No further action is required Year 2000 Test Procedure Use the following steps to test for the change to the year 2000 and then reset to the current date 16 Press the Power switch on the analyzer and then press the Q key while the is displayed in the upper left hand corner of the screen The System Maintenance Menu will be displayed 17 Type 14 and press enter to select option 14 Go to DOS 18 Type date and press enter Follow the prompts to enter the date you wish wi
33. ys the message Please insert system floppy disk amp hit any key then restart disk mount Insert the MU5907 SPECIAL TOOL for YEAR 2000 floppy disk into the FD drive and press the Enter key on the keyboard Wait until the DPR displays the message from FIG 6 Type GO2000 and press the Enter J key on the keyboard see FIG 7 Wait until the DPR displays the message from Fig 8 Note If any errors are displayed during steps 60 to 62 refer to the Appendix Error List 63 64 65 66 67 68 Remove the MU5907 SPECIAL TOOL for YEAR 2000 floppy disk Move the BOOT switch on the rear side of the DPR from FD to WD When moving the switch please pull out on the switch If the switch is not pulled it cannot be moved FIG 12 9 Switch OFF the LOCAL POWER button on the rear side of the DPR FIG12 Power on the equipment using the POWER ON switch on the front of the DPR Execute preparation check after program loading completes The Start Condition menu is displayed In the Start Condition menu check the following a Check that the date and time displayed on the top right of the screen is correct b Execute data index change entering for date Check that the date of the new index indicates the correct date Note Measurement done in the current index with the year set to 2000 will remain on the hard drive and may cause some confusion When testing is complete use the following steps to return to the curre
Download Pdf Manuals
Related Search
Related Contents
Panasonic SC-NE3 Speaker System User Manual CKS1 Compact Stainless Steel Kettle User Manual CKS1 Compact PE-39-10 本質安全防爆形湿度センサ HNシリーズ 3 - Industry Support Siemens [型番] RAD-53。 DA,RAD-530NA`RAD-530WA,RAD File istruzioni Eaton P5MLP1 rack accessory Blizzard Lighting, LLC www.blizzardlighting.com Waukesha, WI USA Rexel 2100020 stapler Copyright © All rights reserved.