Home

Nikon 9000ED User's Manual

image

Contents

1. 37 Step 8 5can anid Save idi e eset edet n Ee cree xi eot 39 Step 9 Ej ct and E DA Lc 41 NOUIS 43 The Scan MNAO 44 The Control Area The Information Panel The Preview and Scar ButtOris nece cte tete e Dade ct cepe tuere et RE 46 The Thumbnail Drawer Tab 47 Th Preview Arei erep etate ecce E tc teu Dane a te pe a D 47 Th Progress WindOW ice e certe ed e dece c a e ee D a e e neat 47 MA TOOL Chiste eee era ane onte ere E lee EN INR RE D ee EORR 48 Optional HOldel e 51 FH 869M Holder for Medium Format Slides esses eene nnne nnn 53 Inserting Slides 53 Removing Slides 53 FH 869G Glass Covered Holder for Medium Format Film 54 Inserting Film it ec t tre err te D ee rn ea e Dade e RR ED ra Ear p e tastes 54 Removirig Film tene rei to IE ER D re e I e D e ERO ED EYE op Ee Rs 55 FH 869GR Rotating Holder for Medium Format Film si 56 Inserting Eit aet test te o e EE e e rp ra E PERI ER ek ci doi FREIE ON seeds 56 REMOVING FAA s eh tte e o e E E D RRO GO SO DERE ERSTE RERO has 57 FH 816 Holder for 16 mim Film it e telo e c ce ee dece be T EROS 58 Inserting Film 58 REMOVING AIME arces een a Sch ok rd aes rad Set nn ee acs ong eere rx estoy ee petes irte ree Mate tea ea ARA 59 FH 8G1 Medical Holder 2 n anie Re atre eh es e ee 60 Iris rtinig Slide
2. Mac OS 9 e The software was successfully installed 4 Installation has completed successfully Please restart your computer E CX Viewing the Easy Scanning Guide Macintosh Insert the Nikon Scan 4 Reference Manual Easy Scanning Guide CD and double click the easy guide OSX icon Mac OS X or easy guide OS9 icon Mac OS 9 The Macromedia Flash Player will start and a language selection screen will be displayed click the appropriate link to view the guide in the desired language The Easy Scanning Guide can also be copied to the computer hard disk for ease of reference total size approximately 200MB Copy the easy guide main folder and easy guide OSX Mac OS X or easy guide OS9 Mac OS 9 to the desktop Users of Mac OS X should ensure that the start up disk is named using only letters and numbers the default name for the start up drive is Macintosh HD The guide may not start if the volume name contains punctuation or other non alphanumeric characters eoo Nikon o o mem Rew A easy guide OSX manual N 4 manual pdf Computer Home Favorites Applications 19 Installing the Scanner Step 1 Choose a Location Choose a flat stable location close to the computer V4 Installing the Scanner Do wor install the scanner where other objects would block its vents or where it would be exposed to direct or reflected sunlight e condensation or rapid temperature changes
3. Select Uninstall Select Uninstall from the menu at the top left corner of the installer dialog and click the Uninstall button to remove Nikon Scan and its components from the computer Click OK A confirmation dialog will be displayed when removal is complete Click OK ee Nikon Scan installer Fus 8 Reade SSS CICR the Uninstall Dutton to uninstall Nikon scan 4 Nikon Scan Plugin 4 e Profiles e The uninstall was successful However some files J folders could not be deleted because they are shared by other applications are currently in use or contain Custom Install Macintosh Only The Macintosh version of Nikon Scan offers a custom install option that can be used to install selected program components as described below 1 Display the Nikon Scan Installer dialog After quitting any applications that may be running insert the Nikon Scan CD in the CD ROM drive and display the Nikon Scan Installer dialog as described in steps 2 7 of the Uninstall Macintosh section eum 71 72 2 Select Custom Install Select Custom Install from the menu at oo Nikon Scan installer the top left corner of the installer dialog een es and select or deselect components for on Sean rugn installation by clicking the boxes to their roms left e needed 84 792K Cosa 3 Click Install Click Install to begin installation of meten the selected comp
4. electromagnetic interference from other electronic devices e temperatures over 35 C 95 F or below 10 C 50 F excessive dust e water vapor from a humidifier or similar device e smoke Leave at least 5cm 2 clear above and on either side of the scanner 10cm 4 behind and 50cm 20 in front 50cm 20 Step 2 Connect the Power Cable 1 Make sure the power switch is in the off position E T I Off position On position Connect the power cable Connect the power cable as shown and plug the scanner into a general purpose house hold outlet Shape of plug varies with country or region of purchase 21 Step 3 Connect the IEEE 1394 Cable 1 Make sure that the scanner is off 2 Connect the IEEE 1394 cable Connect the supplied IEEE 1394 cable as shown below Connect the scanner directly to the computer do not connect the cable via an IEEE 1394 hub or adapter V4 Connecting the IEEE 1394 Cable Connect the cable as shown When connecting the cable to the computer use a six pin IEEE 1394 Firewire terminal like that shown in the cross section below Attempting to insert the connectors in another orientation or using the wrong connector could not only damage the connector but also the scanner or computer Six Pin IEEE 1394 Firewire Terminal and Connector Cross Section Ces Align rounded edge of connector circled above at right with matching cur
5. E Nikon SUPER COOLSCAN 9000 ED 1 00 IEEE1394 DER B I d x gt gt LEE AA NEA E 3 3 le m gt piv 3 3 a A 3 le lv Hr bw Digital ICE4 Advanced Analog Gain a zz E x a Lu a amp 8g lis lia le le lle dr T 23 ae d i gt Progress Window No scanning items Nikon Scan Is Unable to Find Any Active Devices If the message shown at right is displayed when the scan window Nikon Scan E opens check that the scanner is connected and turned on and that the status LED is not flashing If the scanner is connected to a Win Ej dows computer check that the scanner has been registered with the Windows Device Manager ffl 74 FA Temporary Storage Windows Only If the message shown at right is displayed click OK Nikon Sean 3 The folder specified for temporary files is not available The default folder will be used ET 31 Step 4 Insert the Holder 1 Check the status LED Make sure that the status LED is glowing steadily Do not insert film holders while the status LED is blinking 2 Find the arrow on the front of the holder The front each holder is marked with an embossed arrow showing the direc tion of insertion When the holder is inserted the side with the arrow should face up with the arrow pointing toward the scanner 3 Insert the holder Keeping the holder straight slide the it into the holder slot with
6. Settings Color Space Wizard Thes me that determines the basic characteristics of output t ese Ecchi eee Do you wish to select a color space from the name lit or Use the Profile Selection Wizard Use name list Note that choosing the correct color space profile is very important if the scanner is used in a professional setting for example as part of a production workflow For more infor mation on choosing an RGB color space profile see the Nikon Scan Reference Manual on CD Your national Nikon office may also be able to provide or recommend color management training resources 1 Click Windows Clicking Use Wizard in the opening dialog of the Color Space Wizard dis plays a platform selection dialog Click Windows 1 Select sRGB In the Windows Color Space Wizard se lect SRGB recommended and click OK For more information on color space profiles see the Nikon Scan Reference Manual Windows 98 SE If the computer displays a message stat ing that an IEEE 1394 update is required click OK to continue with installation Once installation is complete and the computer has restarted update the IEEE 1394 drivers G 65 Color Space Wizard If you willbe scanning images destined for the Macintosh platform Press the Macintosh button If you will be scanning images destined for the Windows platfom Press the Windows button Cue T Ce Wizard Windows There are seven choices of color
7. conversion Output Full color or greyscale at 8 or 16 bits per channel Focus Auto and manual Interface EEE 1394 Power consumption 27W or less 14W or less in standby mode Power supply AC 100 240V 50 60 Hz JTE ALORS 10 35 C 50 95 F at a humidity of 20 6096 Size and weight 249 x 498 5 x 202 mm 9 8 x 19 6 x 8 0 WxHxD 9kg 19 8lb approx 76 Scanning time With FH 835M 35 mm slide mount holder Time to display image Scanimage when Preview button is Enhancer ICE ROC GEM DEE Preview Scan clickedrorwhen scan ae On OF of or or as 4s lowing preview Times edv o on OM of of Ms s rM o of On of of j 28s 52s ing off of of On Off 26s tmin3ts off of of off On 14s tmin 27s On On On On j On j 33s 2min 335 With FH 869S 120 220 film holder Scan Image Enhancer ICE ROC GEM DEE Preview Scan Don or ot off of 35 _ 3min 14s or on of om or 405 _ 7min 055 or om on om or Tin zes Emin 55s or or OT on or umi 265 Thin 405 Con on on on or ie 243 Tern oos Times for positive film scanned at input resolution of 4000 dpi 2000 dpi when FH 8698 is used with Digital DEE and bit depth of 16 bits CMS on using Nikon Scan 4 on Pentium 4 3 06 GHz FSB 533 MHz computer with 1 GB RAM Windows XP Professional IEEE 1394 interface and 1024 x 768 display t Input resolution set to 2000
8. ATAJATAPI controllers Zr mim I S wong devices 33 Mon SUPER COOLSCAN 9000 ED 75 Specifications SUPER COOLSCAN 9000 ED LS 9000 ED Media Negatives and positives in color and monochrome orama film can be scanned with optional FH 869GR film holder 35 mm slides 1 5 slides with mounts 1 0 3 2 mm thick METTENT 1 4 frames 6x4 5 1 3 frames 6x6 or 1 2 frames 6x7 6x8 or 6x9 NER T TELE S IE 399 Slides with mounts 1 0 3 2 mm thick can be scanned with optional FH 869M film holder 16 mm film 1 3 strips of 1 20 frames can be scanned with optional FH 816 film holder Glass microscope 1 3 prepared glass microscope slides 26 x 76 mm 0 8 1 5 mm thick can be slides scanned with optional FH 8G1 film holder Aperture scan range FH FH FH 869S FH 869G FH FH 835S 835M 6x4 5 6x6 6x7 6x8 6x9 5 9x8 2 816 8G1 Aperture mm 25 4 37 5 56 9 56 9 56 9 56 9 569 56 9 15 0 46 02 x x x x x x x x x x Scan range pixels 64 8964 8964 8964 8964 2362 7248 x x x x x x x x x x 5904 4032 6696 8964 11016 13176 13176 Scanning system Fixed optical movable media parallel single pass scanning system Light source Red Green Blue and Infrared RGBIr LEDs slit light source with rod and disperser Image sensor 10 000 pixel three line monochrome linear CCD image sensor Color separation Performed by RGB LEDs Optical resolution Up to 4000 pixels per inch PREISE Inc 16 bits per color
9. File Convert to CMYK IP B File Quality No Compression i Desktop Shalom 2 Camel f Save My Documents Macintosh My Computer MyNetwak Fle name revu E Save e Saveastpe TIFF Format Cancel Windows Printing Images Images can be printed by selecting the print command from the File menu in the host application If Nikon Scan is being used as a stand alone application under Windows the image in the active win dow can also be printed by clicking the button in the toolbar See the Nikon Scan Reference Manual for more information 40 Step 9 Eject and Exit 1 Eject the holder Press the eject button on the front of the scanner or click the eject button in the Ex Nikon SUPER COOL control area of the scan window Ejec S ES Di tion is complete when the status LED has p Tg d stopped blinking V Removing Holders Wait until ejection is complete before removing the holder by hand Eject button Exit the host application Select Exit Windows or Quit Mac OS 9 from the File menu In Mac OS X open the application menu and choose the Quit option for the host application Remove the scanner from the system Windows Me Windows 98 SE only Windows Me Shut down the computer and turn the power off Windows 98 SE Click the Unplug or Eject Hardware icon in the task bar and select Stop Nikon SUPER COOLSCAN 9000 ED from the menu that appears A message will be displayed stating that the scann
10. IEEE 1394 devices disconnected Do not connect two or more scanners to the computer simultaneously 74 Protecting film Before scanning film remove dirt and dust with a blower This will not only keep the film free of scratches but will also help prevent scanning errors and malfunctions Remove fingerprints with a soft dry cloth being careful not to scratch the film e Remove film from the holder after scanning Storing film in the holder could damage the film e The film base and emulsion will deteriorate if exposed to high temperatures or humidity Be sure tem perature and humidity are within the limits given below e Sudden changes in temperature and humidity even when within the limits stated below can cause condensation on the film Check before use to ensure that no condensation is present If condensa tion has occurred leave the film out until it dries Condensation can damage the film during inser tion The operating environment for the scanner is as follows Temperature 10 35 C 50 95 F Humidity 20 60 Setup This chapter contains all the information needed to set up the scanner for use including installing Nikon Scan and connecting the scanner to a computer Setup and Scanning Guide 8 Installing Nikon Scan 10 Installing the Scanner 20 Setup and Scanning Guide This figure outlines the steps involved in installing the scanner and making a scan Refer to the page numbers l
11. Layout Tools palette in the Tool Chest ff 48 Click to display Layout Tools palette contains buttons for rotating and flipping images Tdlol Palette 1 Layout Tools a linfasmatinn Button Function Rotate image 90 clockwise Rotate image 90 counter clockwise _z Layout Tools Flip image horizontally Flip image vertically Orientation of letter R reflects any flips or rotations that have been performed R turns red when image is flipped 36 Step 7 Select a Crop To scan only part of an image into the host application use the Crop Tool in the Layout Tools palette to select the desired area This selection is referred to as a crop Open the Layout Tools palette Click the triangle next to Layout Tools in the Tool Chest if the Tool Chest is not already open click the Tools button in the scan window and select Tool Pal ette 1 from the menu that appears 2 Select the Crop Tool 3 Select a crop To select a crop drag the mouse over the image in the preview area The borders of the crop are indicated by a dotted line The size of the crop can be changed by dragging its borders To change the po sition of the crop place the cursor inside the selected area and drag it to a new location Repeat this step for the other images selected in the thumbnail drawer To display images in the preview area open the thumbnail drawer and click the se lected thumbnails Cli
12. Mhe Scan Window The parts of the scan window are identified below Thumbnail drawer tab ffi 47 Control area G4 45 Preview area ffl 47 MES AN 9000 ED 1 00 IEEE1394 5 X Information panel 46 uem Progress Window No scanning items Preview button 000 id 40 4 Progress window Scan button fW 46 3 47 44 The Control Area Settings zMealLolo Eject button Ejects the holder from the scanner Autofocus button Click to focus the scanner Control click Windows or option click Macintosh to select a new focus point Autoexposure button When this button is clicked the scanner analyzes the current image and adjusts exposure for optimal results Zoom buttons Click to zoom in for a closer look at the portion of the image currently se lected in the preview area Click to zoom out Settings menu Save and load settings or reset settings to default values Film type menu Choose an option that matches the type of film being scanned Positive for posi tive or reversal film Neg Color for color negatives or Neg Mono for black and white negatives A separate Koda chrome option is available for scanning Kodachrome positives Frame size menu Choose the frame size when scanning medium format 120 220 or Brownie film in the FH 869S or optional FH 869G or FH 869GR film holders Color model menu Choose a color model according to how the image
13. The default install location for Nikon ban San 4S Scan is displayed under Destination defe whee setup mit es Folder To choose a different location Setup vil al Nikan Sean inthe long fider click Browse and navigate to the de mal pmt e OEA NON ege Pt D sired folder Click Next to install Nikon Scan to the selected folder Destinat C Program Fles NikoniNkScand lt Back Wd Next Cancel Click Yes Click Yes to create the destination Confirm New Folder fo ld e r You have entered the following folder specification C Program Files Nikon NkScand This folder does not exist Should setup create it for you Select the scanner drivers Select LS 4000 8000 9000 and click Next Select the divers you want to install and deselect the divers you do nol want to instal CEE ee le A Thie wilinstal device divers for the following scanners SUPER COOLSCAN 4000 ED SUPER COOLSCAN 8000 ED SUPER COOLSCAN 9000 ED 26 73 MB of space required on the C dive 201 31 MB of space available on the C dive Windows 2000 Professional eee E A Digital Signature Not Found dialog been tested with Windows and that the software has not been altered since t was tested will be displayed twice click Yes each ee time if the LS 40 50 5000 scanner jueces drivers were not selected this dialog will be displayed only once I you wart to search for Microsoft digitally signed software visit
14. dicem Locate ntmap sys Select drive c from the Drives menu In the Folders list double click first on windows then system32 and final ly drivers Confirm that ntmap sys is selected in the list of files and click OK 65 Installing the IEEE 1394 Firewire Interface Board 1 Turn the computer off Turn the computer off and disconnect all cables 2 Insert the IEEE 1394 Firewire interface board Insert the supplied IEEE 1394 Firewire board as shown For information on the location of the PCI slots and on install ing PCI boards see the documentation provided with the computer and the IEEE 1394 Firewire interface board V4 Installing the Interface Board Cm Do not use force Excessive force could damage the computer or board Installing the Device Drivers Windows Only After installing the IEEE 1394 Firewire interface board reconnect the cables and turn the computer on Windows XP Windows 2000 Professional Windows Me Windows XP Windows 2000 Professional The first time the computer is powered on with the board installed under Windows XP or Windows 2000 Professional Windows will automatically install the necessary drivers Con firm that the drivers have been correctly installed as described on the opposite page Windows Me The first time the computer is powered on with the board installed the Add New Hardware Wizard will be displayed Select Automatic search for a better
15. dpi Supplied Film Holders FH 835S 35 mm Strip Fitm HOLDER Film Size and weight 130 x 320 x 17 mm 5 1 x 12 6 x 0 7 WxHxD 200 g 7 1 oz approx FH 835M 35 mm Mountep Fitm HOLDER 1 5 35 mm slides with mounts 1 0 3 2 mm thick and 49 0 50 8 mm wide Size and weight 130 x 345 x 17 mm 5 1 x 13 6 x 0 7 WxHxD 180g 6 3 oz approx FH 869S 120 220 Strip Film HOLDER Film Medium format 120 220 film 5 9x8 2 cm electron microscope film 6x45 6x6 6x7 6x8 6x9 Size and weight 130 x 320 x 17 mm 5 1 x 12 6 x 0 7 WxHxD 290g 10 2 oz approx 77 Optional Film Holders FH 869M 120 220 Mountep Fitm HOLDER Film One 6x4 5 or 6x6 slide and one 6x7 6x8 or 6x9 slide Size and weight 130x320x 17 mm 5 1 x 12 6x 0 7 WxHxD 1709g 6 00z approx FH 869G 120 220 Strip Film HOLDER WITH GrAss Film Medium format 120 220 film 5 9 x 8 2 cm electron microscope film 6x4 5 6x6 6x7 6x8 6x9 Size and weight 130 x 300 x 17 mm 5 17x 11 8 x 0 7 WxHxD 300g 10 6 02 approx FH 869GR Rotatine 120 220 Strip Fit HOLDER WITH GLASS Film Medium format 120 220 film 5 9x8 2cm electron microscope film 35 mm panorama film with frame size of 24x 48mm or 24x65 mm 6x4 5 1 4 frames ET 1 3 frames EIA ELMER 1 2 frames Angle adjustment Size and weight 130 x320 x 17 mm 5 1 x 12 6x0 7 WxHxD 330g 11 60z approx FH 816 16 mm Strip Fitm HOLDER Film 1 3 strips of 16 mm film e
16. guarantee that this software works correctly with Windows Nikon SUPER COOLSCAN 9000 ED If you want to search for Microsoft digitally signed software visit the Windows Update Web site at htp vindowsupdate microsoft com to see if one is available Do you want to continue the installation No More Info If the status LED flashes quickly about five times a second turn the scanner off wait at least five sec onds and turn the scanner on again If the problem persists see Troubleshooting Rf 63 24 p 2 Place Film in the Holder The film holders provided with the scanner can be used to scan 35 mm film 35 mm slides medium format film and 59 x 82 mm electron microscope film Choose a holder Choose a holder appropriate to the type of film Film holder 35 mm film in strips of up to six frames 35 mm slides Medium format 120 220 2 or Brownie film or 59x82 mm electron microscope film Z Caring for Holders and Film Keep holders and film free of dust If necessary remove dust from holders and film with a blower before scanning Dust on the film or holder could damage the film or affect the quality of the scanned image n 5 CX Optional Film Holders Optional film holders are available for 16 mm and panorama film medium format slides and glass mi croscope slides For more information see Optional Holders 51 25 2 Place film in the holder FH 835S Holder for 35 mm F
17. reduce noise e Scan Bit Depth Choose a bit depth of sixteen or eight bits Digital ICE will not produce the desired results with monochrome film unless developed in color Kodachrome Film When scanning Kodachrome film in the 9000 ED select Kodachrome in the film type menu 50 Optional Holders This chapter describes the optional film holders avail able for the SUPER COOLSCAN 9000 ED FH 869M Holder for Medium Format Slides 53 FH 869G Glass Covered Holder for Medium Format Film 54 FH 869GR Rotating Holder for Medium Format Film 56 FH 816 Holder for 16 mm Film 58 FH 8G1 Medical Holder 60 51 The following optional film holders are available for the SUPER COOLSCAN 9000 ED Film holder Ed om FH 869M 120 220 Mounten FiLM HOLDER 6x4 5 6x6 6x7 and 6x9 slides FH 869G 120 220 Strip Fita Horper witH Grass Medium format 120 220 2 or Brownie film and 59x82 mm film for electron microscopes Medium format 120 220 2 or Brownie film and 59x82 mm a for electron microscopes FH 869GR RoTATING 120 220 Fitm Horper witH GLASS Panorama film FH 816 16 mm Fitm HOLDER One to three strips of 16 mm film up to twenty frames in length ll inini FH 8G1 Mepicat Supe HOLDER Glass microscope slides 26 x 72 mm of pre pared tissue samples 52 FH 869M Holder for Medium Format Slides The FH 869M is used with medium format 120 220 2 or Brownie
18. the arrow up and facing toward the scanner Once the holder has been inserted as far as the insertion guides the automatic loading mechanism will activate Remove your hands from the holder when loading starts When loading stops the holder is in scanning position V4 Inserting Holders If the loading mechanism is does not ac tivate remove the holder and try again Do not use force Once loading has begun do not interfere with the load ing mechanism Attempting to remove the holder during loading or otherwise interfering with the mechanism could cause scanning errors PSS Insertion guide Calibration The scanner is automatically calibrated at regular intervals if left on with no holder in place Calibration will end when a holder is inserted 32 Step 5 Choose a Film Type and Color Model The steps that follow involve the controls in the Nikon Scan scan window The names and functions of the controls in the scan window are described below Control area Bf 45 Contains frequently used scanning and pre view controls Information panel fg 46 Lists information on current settings Preview button f 46 Click to view selected frames in the preview area where they can be enhanced using the tools in the Tool Chest Scan button Qf 46 Click to scan the selected frames Thumbnail drawer tab fi 47 Click to select frames to be previewed or scanned Processed Natural tabs fff 47 The Processed
19. to observe this precaution could cause electric shock Dust on or near the metal parts of the plug should be removed with a dry cloth Continued use could result in fire Do not handle the power cable or go near the equipment during thunderstorms Failure to observe this precaution could result in electric shock CD ROMs The CD ROMs on which the software and manuals are distributed should not be played back on audio CD equipment Playing CD ROMs on an audio CD player could cause hearing loss or damage the equip ment CAUTIONS Do not handle with wet hands Failure to observe this precaution could result in electric shock 74 Install only as directed Failure to install the device as directed in this manual could block the vents causing overheating and possibly fire 74 Do not place on unstable or sloping surfaces The device could fall resulting in injury or damage Should glass parts inside the device break as the result of a fall or other accident care should be taken to avoid injury caused by broken glass 74 Do not place heavy objects on the device The objects or device could overbalance or fall causing injury Unplug before cleaning Turn off and unplug the device before cleaning Failure to observe this precaution could result in injury 1 Do not insert fingers in equipment Do not insert your fingers in the device save where indicated otherwise Failure to observe this precau tion could result in injur
20. will be processed or used Tools button Click to open the Tool Chest or progress window Help button Click to open Nikon Scan help Prefs button Click to open the Preferences dialog 45 The Information Panel D ital G E M Digital ICE 0 Digital DEE Orientation Shows the orientation of the image in the preview area reflecting any flips or rota tions that have been performed Dimensions file size Lists the width and height of the current selection in pixels and the size of the file that would be produced if the selection were scanned at current settings Image enhancement Shows the current status of Digital ICE Advanced and analog gain Note that using Digital ICE Advanced can increase scanning times The Preview and Scan Buttons Scanner extras Lists the current bit depth which deter mines the maximum number of colors available and shows whether multi sample scanning is in effect Q Color values Lists the color values for the pixel under the cursor The values for the Natural panel are listed in the top row the values for the Processed panel in the bottom row Preview button Click to preview the image to be scanned if multiple frames are selected in the thumbnail drawer a preview will be performed for each frame Be sure to click this button after changing the film type or choosing a new value for analog gain 46 Scan button Scans the images and opens them in the hos
21. 2 41 5 22 10 19 70 72 65 69 74 75 25 29 4 20 33 38 24 24 41 22 41 10 15 63 Y Other IEEE 1394 devices are connected and turned on Disconnect the other devices If the scanner is connected via a hub 5 22 adapter or extension cable disconnect the scanner and reconnect it directly to the computer If this does not solve the problem unin stall all software that uses the IEEE 1394 interface and reinstall Nikon Scan Interface board is not compatible At the time of writing operation has been confirmed only with the 10 15 interface board provided with the scanner Operation is not guaran 64 69 teed with other boards or with built in IEEE 1394 ports Install the supplied interface board desktop computers or consult a Nikon ser vice representative for information on approved IEEE 1394 interface boards or cards Interface board is not correctly installed Computer does not recognize scanner continued Check the documentation provided with interface board or card 64 69 Scanner device driver is missing or corrupted Windows only Check that the device driver is correctly installed 74 75 Nikon Scan is not correctly installed Uninstall and reinstall Nikon Scan For more information see the 10 18 Nikon Scan Reference Manual 70 72 IEEE 1394 drivers require updating Windows 98 SE only Update the IEEE 1394 drivers 65 Installing the IEEE 1394 Firewire Interface Board Users
22. ET 5 introduction Thank you for your purchase of a Nikon SUPER COOLSCAN 9000 ED film scanner Read this manual thoroughly before use and keep it handy when using the product To make it easier to find the information you need the following symbols and conventions are used This icon marks cautions information that This icon marks tips additional information V4 should be read before using the scanner to that may be helpful when using the scanner prevent damage to the device This icon marks notes information that This icon indicates that more information is should be read before using the scanner available elsewhere in this manual or in the other documentation provided Principal Features The Scan Image Enhancer automatically adjusts hue to produce images with clear contrast Digital ICE detects analyzes and automatically compensates for scratches and dust Digital ROC digitally restores for faded colors in old film e Digital GEM automatically corrects for film grain smoothing pictures taken with high speed film Digital DEE reveals details in shadows of backlit and underexposed shots and increases con trast in washed out areas of highlights to produce natural looking exposure Illustrations The majority of illustrations showing the scanner interface are taken from Windows XP Professional Where operations in the two operating systems differ illustrations from Mac OS X are also used Terminology In this ma
23. Nikon Nikon Film Scanner SUPER COOL SCcChri S000 Em User s Manual Manuel de l utilisateur Manual del Usuario C Nikon Film Scanner Before vou supeRcooLscan gooOQErL Setup Basic Scanning Nikon Scan Optional Holders User s Manual Product Documentation The documentation for this product includes the manuals listed below Be sure to read all instructions thoroughly Quick Start Guide The Quick Start Guide provides a quick introduction to installing the Nikon Scan driver software for the scanner inserting film and mak ing a simple scan User s Manual this manual This User s Manual provides detailed instructions for installing and using a SUPER COOLSCAN 9000 ED film scanner LEE eee Vea The Nikon Scan Reference Manual provides complete information Easy Scanning Guide on Nikon Scan the software used to scan images into the com on CD puter This manual is stored on the reference CD in pdf format and can be viewed using Adobe Acrobat Reader 4 0 or later If neces sary Windows users can install Adobe Acrobat using the installer provided on the reference CD For more information on installing Adobe Acrobat Reader and viewing the reference manual see the Quick Start Guide The Easy Scanning Guide uses animation to explain such basic scan ning tasks as setting image size and resolution See the Quick Start Guide for viewing instructions MURBA EAV ETEA The Nikon View Reference Ma
24. Windows 98 SE The first time the computer is powered on with the board installed the Add New Hardware wizard will be displayed 1 Click Next Click Next to start the Add New Hard ware wizard This wizard searches for new diivers for NEC Firewarden OHCI Compliant IEEE 1394 Host Controller A device diver is a software program that makes a hardware device work 2 Select the search option Select the search option and click Next 3 Deselect all search location options After confirming that none of the search drivers in its diver database location options are selected click gr dre mdr ay era Next 4 Choose the recommended driver Select The updated driver Recom mended NEC Firewarden OHCI Compliant IEEE 1394 Host Controller and click Next Windows has found an updated driver for this device and also some other divers that should work with this device 68 Click Next The dialog shown at right will be dis played Click Next The Insert Disk Dialog If the Insert Disk dialog is displayed insert the Windows 98 Second Edition CD and click OK If Windows displays a message stating that a file could not be found enter the drive letter of the CD ROM drive followed by Nwin98 se e g dNwin98 se in the Copy files from text box and click OK Click Finish The dialog shown at right will be dis played Click Finish Open the System Properties dialog After t
25. ace may be required depending on the film type and number of frames Nikon recom mends having as much free disk space as possible when running Nikon Scan If the computer is not already equipped with an IEEE 1394 Firewire interface install an approved OHCI compliant IEEE 1394 interface board or card for a list of approved boards or cards see the Nikon web site for your area 4 2 The IEEE 1394 interface board provided with the scanner can be installed in desktop computers with an empty PCI slot fW 64 Note that the supplied board can not be installed in laptop computers or low profile PCI slots Windows 98 SE Before installing Nikon Scan on a computer running Windows 98 SE be sure to update the IEEE 1394 drivers Qf 65 Windows XP Windows 2000 Professional When installing or uninstalling Nikon Scan under the above operating systems log in as the Computer administrator Windows XP or Administrator Windows 2000 Professional Earlier Versions of Nikon Scan Before installing Nikon Scan 4 uninstall any earlier versions of Nikon Scan See Uninstalling Nikon Scan Ri 70 Nikon View For information on installing and using Nikon View see the Nikon View Reference Manual on CD 10 1 Insert the Nikon Scan CD into the CD ROM drive A language selection dialog will be uf Select Language Welcome to the world of Nikon Digital photography displayed Select a language and click Pesce oni cea Next FI If
26. ach with 1 20 frames Size and weight 130x375 x 17 mm 5 1 x 14 8 x 0 7 WxHxD 2509 8 8 0z approx FH 8G1 Mepicat HOLDER Media 1 3 prepared glass microscope slides Slide 6x 76mm 0 8 1 5mm thick Slide cover 25 x 60 mm with thickness of 0 18mm or less Total thickness No more than 2mm including adhesive Size and weight 130 x 345 x 17 mm 5 1 x 13 6 x 0 7 WxHxD 1909 6 7 oz approx 78 Index Symbols 2 see Film medium format 16 mm see Film 16 mm 35 mm see Film 35 mm 120 220 see Film medium format A Acquire plug in 17 30 Adobe Photoshop 8 17 30 Analog gain 50 Aperture 76 Autoexposure 45 Autofocus 45 B Bit depth 38 50 Brownie see Film medium format C Calibrated RGB 34 Calibration 32 Color balance 49 Color model menu 34 45 See also Calibrated RGB Grayscale Color space profile 13 17 18 Color values 46 48 Control area 33 44 45 Crop 37 38 48 Curves 49 D Device drivers 12 74 75 Digital DEE 2 50 58 60 Digital GEM 2 50 58 60 Digital ICE 2 50 60 Digital ICE Advanced 9 50 Digital ROC 2 50 58 60 E Eject button 41 Nikon Scan 41 45 scanner 3 41 Ejecting film see Film ejecting Electron microscope film see Film electron microscope F File size 48 Film 5 9 25 29 42 52 60 16 mm 58 59 35 mm 9 26 27 slides 9 28 60 base 26 caring for 5 25 color 34 curl 29 ejecting 41 electron microscop
27. ale of the SOFTWARE and you do not become the owner of the SOFTWARE Khrough your purchase download or use Nikon and or Nikon s licensor retain ownership of the SOFTWARE and all copies thereof and reserves all rights not expressly granted to you under this Agreement This Agreement constitutes the complete and exclusive agreement oral or written between us or any associated company of ours relating to the SOFTWARE Print Save As Decline View the ReadMe file Take a few moments to read this file which may contain important information that could not be included in this manual Click Continue to continue with installation Click Install Click Install to begin installation Nikon Scan Installer f Read Me Click the Install button to install Nikon Scan 4 Nikon Scan Plugin 4 Profiles Selecting a Plug ins Folder Mac OS 9 If a copy of the Nikon Scan plug in is installed in the plug ins folders for sup ported versions of Adobe Photoshop Photoshop can be used to acquire im D ages directly from the scanner If more LO than one copy of Photoshop is installed Ebo on the computer a list will be displayed Select the copies of Photoshop that will be used to acquire images and click Con tinue to copy the Nikon Scan plug in to the appropriate plug ins folders Click Use wizard recommended Click Use wizard to choose an RGB o Color Spac
28. anager lists al the hardware devices installed IRA on your computer Use the Device Manager to change the properties of any device CL Diver Signing M Device Manager i Hardware Profiles ix Hardware profes provide a wap for you to set up and store A different hardware configurations V Geni A Device Manager Bidare Profies Performance View devices by type T View devices by connection EE 1394 Bus Controler fF CDROM 56 9 Disk drives 1 l8 Display adapters 4 Floppy disk contiolers FD Hard disk controlers E Imaging Device Nikon SUPER COOLSCAN 9000 ED H Keyboard E Monitors 8 7 Mouse GER Network adapt 8 49 Other devices p Y Pots COM amp LPT mp nm Properties Retesh Remove Pin Check that the scanner is listed as an imaging device Click the next to Imaging devices Windows XP Windows 2000 Profes sional or Imaging Device Windows Me Windows 98 SE and confirm that the scanner is listed vV If the Scanner Is Not Listed If the scanner is not listed or appears next to a I or x the drivers have not been correctly installed Dis connect the scanner and uninstall Nikon Scan then reinstall Nikon Scan and re connect the scanner Device Manager File Action View Help meum 1 Computer FF lt Disk drives Display adapters 1 d DVD CD ROM drives Cj Floppy disk controllers B Floppy dik drives IDE
29. ck to display Layout Tools palette T ol Palette 1 C Layout Tools NI v Layout Tools Show grid Crop Tool AN 9000 ED 1 00 IEEE1394 37 Choosing an Output Size and Resolution The Crop palette in the Tool Chest is used to specify the size and resolution of the crop when opened in the host application c y 30 For ex ample to scan an image so that it can be printed within the margins of A4 21 0 x 29 7 cm or letter sized 117x8 5 paper on a typical inkjet printer Tool Palette 1 gt Layout Tools gt Information 1 Click the triangle next to Crop in the Tool Chest to open the Crop palette eo Vg 2 Choose Keep this Crop and use the mouse to WEIS uBei Fixes select a crop in the preview area eum 37 3 Choose Centimeters or Inches from the out Keep this Qutput Size put units menu Q7 H 116 83 4 Enter a value for Height or Width that will fit on Keep this File Size A4 paper remember to leave a margin of least 2cm 0 79 The other value will automatically 261 MBytes v be adjusted to maintain the current crop if the result is still too large enter a value that will fit Scale 4 H b R3414 x on A4 paper i 860 i 5 Enter an output resolution of 360 pixels per ROLE inch Custom ni Scan Bit Depth The scan bit depth determines the maximum number of colors in the image after scanning A choice of sixteen and
30. curities government bonds or local government bonds even if such copies or reproductions are stamped Sample The copying or reproduction of paper money Coins or securities which are circulated in a for eign country is prohibited Unless the prior permission of the government has been obtained the copying or reproduction of unused postage stamps or post cards issued by the government is prohibited The copying or reproduction of stamps issued by the government and of certified documents stipulated by law is prohibited Cautions on certain copies and reproductions The government has issued cautions on copies or reproductions of securities issued by private companies shares bills checks gift certificates etc commuter passes or coupon tickets except when a minimum of necessary copies are to be provided for business use by a company Also do not copy or reproduce passports issued by the government licenses issued by public agencies and private groups ID cards and tickets such as passes and meal coupons Comply with copyright notices The copying or reproduction of copyrighted creative works such as books music paintings woodcut prints maps drawings movies and photographs is governed by national and interna tional copyright laws Do not use this product for the purpose of making illegal copies or to infringe copyright laws Table of Contents For Your Satety EAA AT E E A cocde cbs sat cuscebesc usteu
31. disk space may be required depending on the film type and number of frames Nikon recom mends having as much free disk space as possible when running Nikon Scan MacOS X Administrator privileges are required to install and uninstall Nikon Scan under Mac OS X Z mac os 9 CarbonLib 1 6 or later is required to install Nikon N one at uour os support tes iron rire n Scan If the installer detects an earlier version of Gr A EU CarbonLib a message will be displayed Click In dire ries T stall to upgrade to a new version of CarbonLib C ss Earlier Versions of Nikon Scan If the installer detects an earlier version of Nikon Won Sean x is installed To use nkon Sean 4 Scan the dialog shown at right will be displayed Nikon SEM Click Yes to upgrade to Nikon Scan 4 x es Nikon View For information on installing and using Nikon View see the Nikon View Reference Manual on CD 15 16 Insert the Nikon Scan CD into the CD ROM drive A Nikon Scan 4 CD icon will appear on the desktop Double click the icon to open the Nikon Scan 4 window Double click the Welcome icon in the Nikon Scan 4 window Choose a language A language selection dialog will be displayed Select a language and click Next Click Easy Install The Install Center dialog will be dis played Open the Software panel and click Easy Install Authenticate Mac OS X Only Clicking Easy Install in the software panel displays the Authentica
32. driver Recommended and click Next to install the drivers for the IEEE 1394 interface board When installation is complete Windows Me will display message stating that the computer must be restarted be fore changes to system settings can take effect Click Yes to restart the computer Proceed to the next step once the computer restarts 66 Display the System Properties dialog Windows XP Select Control Panel from the Start menu open Performance and Main tenance and click System Fa Toos Help O it Dawe pre 4A Performance and Maintenance v Pick a task B Backup your data E rear or pick a Control Panel icon Windows 2000 Professional Windows Me Click the My Computer icon with the right mouse button and select Proper ties from the menu that appears Open the Device Manager Windows XP Windows 2000 Professional Open the Hardware panel and click the Device Manager button Windows Me Click the Device Manager tab Check the IEEE 1394 host controller Confirm that NEC Firewarden OHCI RE Compliant IEEE 1394 Host Controller RID WU ERE is listed under IEEE 1394 Bus host con e trollers Windows XP Windows 2000 Er 81 88 Display adapters Professional or 1394 Bus Controller HET Windows Me Le fer a H E Modem amp Monitors fey Mouse 15 MS Network adapters PCMCIA socket a Ports COM amp LPT ES coni onn 67
33. e 9 25 28 52 54 56 emulsion surface 26 inserting 26 29 53 60 Kodachrome 34 50 medium format 9 25 28 29 52 54 56 slides 52 53 monochrome 34 negative 26 29 34 53 55 58 panorama 52 56 positive 26 29 34 53 55 58 removing 42 53 55 57 59 60 Film holders 9 25 29 51 60 77 78 ejecting 41 FH 816 52 58 59 76 78 FH 835M 9 25 28 76 77 FH 835S 9 25 26 27 76 77 FH 869G 29 52 54 55 76 78 FH 869GR 29 52 56 57 78 FH 869M 52 53 78 FH 869S 9 25 28 29 76 77 FH 8G1 52 60 76 78 inserting 32 Film type menu 34 Firewire see IEEE 1394 Flipping images 9 36 46 48 Frame size menu 34 G Grayscale 34 H Help button 45 Holder slot 3 32 I IEEE 1394 5 10 15 22 64 69 cable 4 5 8 22 driver update Windows 98 SE 10 13 24 65 interface board 10 64 69 interface drivers 66 69 maging applications 8 30 mage windows 9 39 nformation palette 48 nformation panel 33 44 46 nstall see Nikon Scan installing K Kodachrome see Film Kodachrome L Layout Tools 36 48 LCH Editor 49 M ac OS 2 15 19 30 41 64 71 73 aintenance 62 edium format see Film medium format ulti sample scanning 50 N Natural 33 47 Nikon Scan 8 9 10 18 30 31 33 41 43 50 63 64 70 73 See also Scan window installing 10 18 custom install 73 plug in 17 30 starting 30 31 uninstalling 70 72 Nikon View 8 9 10 15 o Orientat
34. e Wizard This is a setup that determines the basic characteristics of color space profile with the help of the i aa Color Space Wizard recommended I cha Rone Scio ee INSEE The selected color space profile can DIT E be changed in the Nikon Scan Prefer ences dialog after installation Note that choosing the correct color space profile is very important if the scanner is used in a professional setting for example as part of a production workflow For more infor mation on choosing an RGB color space profile see the Nikon Scan Reference Manual on CD Your national Nikon office may also be able to provide or recommend color management training resources 17 1 13 18 Click Macintosh Clicking Use wizard in the opening dialog of the Color Space Wizard dis plays a platform selection dialog Click Macintosh Select Apple RGB In the Windows Color Space Wizard select Apple RGB recommended and click OK For more information on color space profiles see the Nikon Scan Reference Manual o Wizard Platform If you will be scanning images destined for the Macintosh platform press the Macintosh button If you will be scanning images destined for the Windows platform press the Windows button This is select a group of color spaces that contain the optimal gamma characteristic for the selected platform If you press the Windows button you will be presented with seven color spaces t
35. e image in each frame appears in its actual colors Use with color negatives Col or negatives can be identified Neg Color by their orange tinted base and by the fact that the colors in the images are reversed Use with black and white Neg Mono negatives Use with Kodachrome posi Kodachrome tives Choose a color model Click the color model menu in the scan window control area and choose a color model according to how the image will be used Option Description Image scanned as grayscale data Use when scanning imag Grayscale 65 that will be printed or viewed in black and white Calibrated Image scanned as RGB data RGB Use to scan images in color Select the frame size medium format film only When scanning medium format 120 220 or Brownie film in the FH 869S click the frame size menu and select the film frame size 8 28 5 Nikon SUPER COOLSCAN 9 Neg Color Ww z Positive F v Neg Color Neg Mono Kodachrome Film type menu E Nikon SUPER COOLSCAN 9 AE i j Color model menu Spa ocem we Zl y 6x 4 5 cm 6 x 6 cm 6 x 7 cm 6 x 8 cm 6 x 9 cm Frame size menu tep 6 Preview Open the thumbnail drawer Click the thumbnail drawer tab Display thumbnails To view the frames in the thumbnail EME ur drawer as small thumbnail previews EE ES EE Thumbnail click the B button The scanner will scan the film to generate th
36. ection and once every three to five years for servicing fees are charged for these services Frequent inspection and servicing are particularly recommended in the case of scanners used in commercial applications 62 Troubleshooting If the scanner fails to function as expected check the problems described below before con sulting the original retailer or Nikon service representative For more information on solving the problems listed here refer to the page numbers in the rightmost column Problem Possible cause Scanner is off Turn the scanner on Power cable is not properly connected Return the power switch to the off position and reconnect the power cable Outlet is not receiving power Plug another device into the outlet to determine whether the outlet is working properly Scanner will not turn on status LED does not light Status LED flickers Scanner hardware malfunction scanner not con Turn the scanner off and disconnect it from the computer Wait five nected to computer seconds and turn the scanner on again If the problem persists con or computer off act a Nikon service representative Scanner hardware malfunction or communications error Turn the scanner and computer off and disconnect the scanner Wait ive seconds and turn the scanner on again If the status LED flickers when the scanner is turned on a scanner hardware malfunction has occurred Contact the original retailer or a Nikon service re
37. eight bits is available in the Scanner Extras palette For more information see the Nikon Scan Reference Manual on CD Centimeters v Scan Image Enhancer The image enhancement tools in the Tool Chest can be used to enhance images before they are scanned For example the Scan Image Enhancer automatically adjusts brightness contrast and hue to produce an image that can be printed or used as is without further alteration note that this will increase scanning times and may not have the desired effect on dark images For information on the Scan Image Enhancer and the other image adjustment options and scan settings available in Nikon Scan see Nikon Scan Ga 43 or the Nikon Scan Reference Manual on CD Easy Scanning Guide The Easy Scanning Guide gives examples of how to adjust Crop palette settings in a variety of situa tions 38 Step 8 Scan and Save Click the Scan button Click the Scan button to begin scanning the crop selected in the preview area Progress is shown in the progress win dow fg 47 Batch Scans If multiple frames are selected in the thumbnail drawer fV 35 clicking the Scan button will display a dialog of batch scan options Click OK to save the scanned images to disk If Nikon Scan is being used as a stand alone applica tion the File Saving Options dialog will be displayed choose a location and file format and click OK to begin scan ning Instead of being opened in image window
38. er can be safely removed from the system click OK Turn the scanner off Scanner on Scanner off Ejecting Holders The holder will be ejected automatically if the scanner is turned off and then on again 41 D Remove the film FH 835S Holder for 35 mm Film Insert your fingers into the holes in the lower portion of the holder and undo the latches Open the holder and use the cutouts to pick the film up by its edges If the edges of the film are not accessible tilt the holder to slide the film to the hollows at either end of the lower holder FH 835M Holder for 35 mm Slides Slide the mounts out from under the clips that hold them in place V4 Do Not Use Force Do not use force when removing slides Failure to observe this precaution could damage the clips holding the slides in place Do not lift the slides up until fully removed from the clips FH 869S Holder for Brownie Film Open the cover and pick the film up by the edge at the rear of the holder 7 Do Not Store Film in the Holder Leaving slides in the FH 835M for extended periods could damage the clips holding the slides in place Film left in the FH 869S for extended periods could develop permanent indentations 42 Nikon Scan This chapter provides a brief overview of the Nikon Scan software that controls the scanner For more informa tion see the Nikon Scan Reference Manual on CD iihe Scan Window E 44 ibhesTooliGhest eR E A 48 43
39. event the installer from starting automatically insert the Nikon Scan CD into the CD ROM drive If the language selection dialog is displayed click Quit 2 Open the Nikon Scan CD in Windows Explorer Double click the My Computer icon Click the icon for the Nikon Scan CD with the right mouse button and select Explore from the menu that appears 3 Run the updater Open the Microsoft folder and double click 242975USA8 or 242975USA8 EXE Follow the on screen instructions to complete the update 4 Restart the computer When the dialog shown at right is dis S EE played remove the Nikon Scan CD from idc nd the CD ROM drive and then click Yes to restart the computer Installing the IEEE 1394 Interface Board Once the computer has restarted users of the supplied IEEE 1394 interface board can install the board A 66 and interface device drivers f 68 69 V4 The Insert Disk Dialog If an Insert Disk dialog is displayed the first time the scanner is connected and turned on O sese doccia the IEEE 1394 driver update has not been completed successfully Do wor insert the Windows 98 Second Edition CD Make sure the CD ROM drive is empty and click OK then update the drivers as follows Click Browse The dialog shown at right will be dis EE laved Cli FEET played Click Browse Cana Insert Windows 38 Second Ecition CD ROM inthe selected drive and click DK Skip File op fles rom E
40. from a third party application application must support Adobe Photoshop 5 0 acquire Macintosh plug ins and a copy of the Nikon Scan plug in must be installed in the application s plug ins folder Images are scanned using Nikon Scan and processed printed and saved in the third party application 2 Open the scan window Application Platform Description Click the Start button and se m z lect Nikon Scan 4 from the B Mon Scan tone programs list If a shortcut El nr Ed mon scan sunnat was created during installa ge Windows tion you can also double click e Ies the E icon on the desktop IX ese Nikon Scan mamorae gt een used as i stand alone Open the Applications Nikon Software Nikon Scan 4 folder on the application Macintosh start up disk and double click the icon If Nikon Scan was added Mac OS X to the Dock during installation you can also click the g icon in the Dock Open the Nikon Software Nikon Scan 4 folder in the folder selected at Macintosh installation the default folder is the Applications folder on the start up Mac OS 9 disk and double click the EZ icon If an alias was created during instal lation you can also double click the g icon on the desktop Dose Select Nikon Scan from the application s list of Acquire or Import panty sources For more information see the documentation provided with application the application 30 The scan window will open
41. hat use a gamma If you press the Macintosh button you will be presented with three color spaces that you use a gamma value of 1 8 Windows o Wizard Macintosh Wizard Macintosh There are three choices of color spaces here 1 Apple RGB 2 Color Match RGB 3 Apple RGB compensated 31 gives you the most vivid color reproduction However it may be too saturated in places 3 maintains the most tonal information possible but it may look flat 2 represents values between these two extremes Please choose one and press the OK button O Apple RGB compensated A sample image is being displayed using the selected color space profile If you think that all color spaces are still too dark press the too Dark button Too Dark Add Nikon Scan to the Dock Mac OS X or create an alias Mac OS 9 Click Yes to add Nikon Scan to the Dock Mac OS X or to create an alias for Nikon Scan on the desktop Mac OS 9 Click No to proceed without adding Nikon Scan to the Dock or creating an alias Add to Dock Nikon Scan 4 0 Add above application s to Dock Click Quit Mac OS X Click Quit to exit the installer Restart the computer Click Restart to restart the computer Scan This completes installation of Nikon Make Alias Nikon Scan 4 TIER Do you want to create alias for this application on your Desktop
42. he computer restarts click the My Computer icon with the right mouse button and select Properties from the menu that appears Check the IEEE 1394 host controller Click the Device Manager tab and con firm that NEC Firewarden OHCI Com pliant IEEE 1394 Host Controller is listed under 1394 Bus Controller Windows driver ile search for the device NEG Fromarden CHCI Conpliant IEEE 1804 Host Windows is now ready to install the best driver for this device Cick Back to select a different diver or click Next to continue Location of driver IF zm OXWNDOWSHNFETSSLINI Ingat Widow 8 Second chien CD ROM inthe selected dive and click OK py fles p winS8 se NEC Firewarden OHCI Compliant IEEE 1294 Host Controller Windows Pelee ae Ree hardware device requies Map Network Die Disconnect Network Drive Create Shotcut Banane System Properties General Device Manager Hardware Profies Performance View devices bytype View devices by connection 69 Uninstalling Nikon Scan Before Nikon Scan can be reinstalled or a new version installed the existing version must be removed from the computer uninstalled The instructions that follow are divided into Win dows and Macintosh sections Export Settings Before uninstalling Nikon Scan export frequently used scan window settings to a location outside the Nikon Scan app
43. his Nikon License Agreement Agreement is a legal agreement between you either an individual lor single entity and Nikon Corporation Nikon setting forth the terms and conditions for your use lof the Nikon software accompanying this Agreement which includes computer software and may nclude associated media printed materials and online or electronic documentation SOFTWARE By installing downloading and or using this SOFTWARE you indicate your acceptance of this Agreement and are agreeing to be bound by the terms of this Agreement If you do not agree to the terms of this Agreement you are not authorized to install download or use this SOFTWARE Promptly return within fifteen 15 days from the date of delivery the package to the authorized INikon Dealer where you obtained it for a full refund This license is not a sale of the SOFTWARE and you do not become the owner of the SOFTWARE through your purchase download or use Nikon and or Nikon s licensor retain ownership of the SOFTWARE and all copies thereof and reserves all rights not expressly granted to you under this Agreement This Agreement constitutes the complete and exclusive agreement oral or written between us or any associated company of ours relating to the SOFTWARE n Print Save As Decline 72 Click Continue The ReadMe file will be displayed Click Continue to display the Nikon Scan Installer dialog
44. ightness and contrast targeted to specific portions of the tone range or use the hue and chroma editors for precise control of color 49 Digital ICE Advanced Digital ICE quad Advanced _ Digital ICE4 Advanced z z Enable Post Processing 4 Enable Digital DEE jJ e 4 gt More gt gt Redraw Four tools are available Digital ICE mitigate the effects of dust and scratches Digital ROC restore faded colors Digital GEM reduce the effects of film grain Digital DEE increase detail in under or over exposed areas of the frame Analog Gain v Analog Gain Analog Gain Master 4 mm 0 Red 4 j o Green 4 pho Blue 4 o e Redraw Reset Adjust exposure values for each of the col ored elements in the scanner s light source Digital ICE Scan Image Enhancer Scan Image Enhancer Redraw Perform automatic brightness color and contrast adjustment Scanner Extras Scanner Extras Manual Focus Adjustment Position 4 bees 218 Help Multi Sample Scanning Mode Normal 13 Help CCD Scan Mode Super Fine Scan Help Scanner Extras M Auto focus when film is inserted Calibrate Help Pixel Data Size Scan Bit Depth 8 Ej Control features specific to the type of scan ner currently connected e Multi Sample Scanning Use this feature to
45. ilm The FH 835S can be used with one or two strips of 35 mm film Each strip can be up to six frames long FK Open the holder Insert your fingers through the holes in the bottom half of the holder and undo the latches then open the holder Latches AD Insert film Place film in the holder with the reflec tive film base up and the matte emulsion surface down Arrow V4 Inserting Film Align the first frame in each strip with an aperture at the left end of the hold V amp er Leaving the apertures at the left Direction of end of the holder uncovered or cover insertion ing them with a masking sheet could cause scanning errors or interfere with accurate color reproduction dan d displayed in Use only one type of film do not mix order shown negatives with positive film Y Inserting Film Do not place film or masking sheets so that they protrude from the holder or overlap the film guides Failure to observe this precaution could cause the holder to jam in the scanner BS 45 Q Film Base Emulsion Surface When film is examined under bright light the image on the emulsion surface will be in slight relief with bumps and hollows where the image has been developed The opposite surface the film base will be reflective and smooth Insert film with the base up 26 P Insert masking sheets When scanning a single strip or strips Masking sheet of different lengths place the film a
46. iod unplug the scanner and store it in a well ventilated area where the temperature is between 10 C 14 F and 50 C 122 F and the humidity less than 6096 Do not store the scanner or holders where they would be subject to sudden temperature changes or condensation Cleaning Turn the scanner off unplug the power cable and place the scanner on a flat stable surface where it will not be damaged in a fall Use a blower or a soft dry cloth to remove dust a soft cloth lightly dampened with neutral detergent or liquid soap to remove tougher stains Do not use alcohol or other volatile chemicals Transport Before transporting the scanner 1 Turn the scanner on and eject any film holders 2 Press and hold the eject button until the status LED stops blinking about three seconds The scan mechanism will lock 3 Turn the scanner off and disconnect the power and interface cables 4 Repackage the scanner in the original packing materials if the original packing materials are unavailable use materials at least as shock resistant as the originals V4 Transporting the Scanner Nikon scanners are only certified for use in the region or country of sale Transport or use outside the region or country of sale is at the risk and responsibility of the user Servicing Nikon scanners are precision devices We recommend that the scanner and holders be taken to an au thorized Nikon service representative once every one to two years for insp
47. ion 36 46 Output size 38 48 P Panorama film see Film panorama Power switch 3 21 24 41 Power cable 4 21 63 connecting 21 Preferences 45 Prefs button 45 Preview area 36 38 Preview button 33 36 44 46 Previewing images 9 35 36 Printing images 9 40 Processed 33 47 Progress window 33 39 44 47 R Resolution 38 48 Rotating images 36 46 48 S Saving images 39 40 Scan button 33 39 44 46 Scan Image Enhancer 2 38 50 Scan window 8 9 30 31 33 39 44 47 Scanner extras 50 Settings menu 45 Status LED 3 5 24 32 41 63 T Thumbnail 35 drawer 35 47 drawer tab 33 35 44 47 Tool Chest 9 33 36 37 38 45 48 50 Tool palettes 48 50 Tools button 37 45 Transport 62 TWAIN 30 U Uninstall see Nikon Scan uninstall ing Unsharp Mask 49 USB 5 22 w Windows 10 14 30 41 63 64 69 70 74 75 98 SE 2 10 12 13 24 41 64 65 68 69 2000 Professional 10 12 24 64 66 67 70 74 75 Me 2 12 41 64 66 67 74 75 XP 2 10 12 64 66 67 70 74 75 Z Zoom buttons 45 79 Nikon NIKON CORPORATION Printed in Japan Fuji Bldg 2 3 Marunouchi 3 chome SB3J00300101 30 Chiyoda ku Tokyo 100 8331 Japan 6MRAO730
48. isk can be viewed and orga nized in Nikon View See the Nikon View Reference Manual on CD for more information Installing Nikon Scan Nikon Scan software provided is required to control the scanner The installation instructions that follow are divided into Windows and Macintosh sections Windows Turn the computer on and wait for Windows to start up Before continuing with installation make sure that e The scanner is Nor connected No other applications including anti virus software are running e The computer satisfies the following system requirements 300 MHz Pentium or better Preinstalled versions of Windows XP Windows 2000 Professional Windows Me 05 Windows 98 SE RAM 128MB or more 512 MB or more recommended Hard disk A minimum of 40 MB required for installation 200 MB or more recommended with spacet an additional 200 MB of free disk space available while Nikon Scan is running CEE SOO x 600 pixels or more with 16 bit color High Color or more IEEE 1394 Only OHCI compliant boards supported TIENNE CD ROM drive required for installation More memory may be required depending on film type scan size resolution bit depth the number of scans performed in each session the adapter used and on whether Digital ROC Digital GEM or Digital DEE is used A system with more than the minimum amount of memory is recommended t More free disk sp
49. isted for more information Install software A94 10 19 Computer Imaging applica tion e g Adobe Photoshop io LEESE EEEE 2 Connect the scanner to the computer f 22 Connect the power cable m 21 Connect the IEEE 1394 Firewire cable SUPER COOLSCAN 9000 ED Turn the scanner on fV 24 j Open the scan window V 30 31 Nikon Scan can function as a stand alone application to scan process and save images or it can be used to scan images directly into an imaging application such as Adobe Photoshop Nikon Scan Imaging application e 9 Adobe Photoshop FERAE III Insert film Qf 32 35 mm film FH 835S fW 26 27 35 mm slides FH 835M 9 28 Medium format film Fes Electron microscope film FH 869S ffi 28 29 Scan images fU 33 39 e Specify the film type and color model ffi 34 e Preview images fW 35 36 e Flip and rotate images ff 36 e Select the area to be scanned f 37 38 Enhance images using the tools in the Tool Chest including Scan Image Enhancer Digital ICE Advanced and curves eum 38 48 50 e Scan images fW 39 zl Tool Chest 8148 50 P J Scan window I 44 47 ETS Save images Wi 40 After scanning images are opened in images windows in the host applica tion where they can be printed or saved fW 40 es n Images that have been saved to d
50. ith Masking sheet the film line on the holder A gap at the leading edge of the film could interfere with accurate color reproduction Film line Thumbnails displayed in order shown Direction of insertion 3 Snap the holder closed Removing Film Tilt the holder to slide the film over the de Depressions pressions at the front of the holder and pick the film up by its edges 55 t Rotating Holder for Medium FormatFilm The FH 869GR is used to scan medium format film 120 220 2 or Brownie 59 x 82 mm electron microscope film or 24x65mm panorama film The angle of the holder can be adjusted by 5 to compensate for camera angle When scanning medium format film the length of the strip that can be inserted depends on the type of film 6x4 5 1 4 frames 6x6 1 3 frames 6x7 6x9 1 2 frames Inserting Film 1 Open the holder Slide the latch in the direction shown and open the holder 2 Insert a masking sheet Align the masking sheet with the guide pins in the holder V4 Use an Appropriate Mask The mask aperture must match the film frame size Gaps between the mask and the film could interfere with accurate color reproduction Masking sheet 3 Insert film Place film on the masking sheet base up i 26 Align the frame to be scanned with the aperture in the masking sheet Aperture 56 4 Snap the holder closed Adjust the film angle Loosen the locking screw by rotating it Angle indicator co
51. lication folder These settings can then be loaded into the scan window once Nikon Scan has been reinstalled For more information see the Nikon Scan Reference Manual on CD Windows 1 Select Nikon Scan 4 Uninstall Click the Start button and select Nikon Scan 4 Nikon Scan 4 Uninstall from the program list 2 Begin the uninstall The dialog shown at right will be dis played Click OK to begin removing Nikon Scan and all of its components If uninstaller encounters read only files or components shared by another ap plication a confirmation dialog will be displayed Read the information dis played carefully before deciding what to do with the affected components Click Finish Click Finish to exit the uninstaller Windows XP Windows 2000 Professional a Nikon Scan 4 E Nikon Scan E Nikon View 6 S9 Nikon Scan 4 Help E QuekTime Nikon Scan 4 ReadMe RI startup Sca E Acrobat Reader 5 1 F Adobe ImageReady 7 0 1 Adobe Photoshop 7 0 1 iB internet Explorer I Outlook Express Nkon View 12 Remote Assistance windows Media Player N MSN Explorer LL 33 Windows Messenger Bio O tum or computer Confirm Uninstall E3 Do you want to completely remove the selected application and all of its components Nikon Scan 4 Setup InstallShield Wizard Complete Nikon Scan 4 Setup has successfully uninstalled Nikon Scan 40 You computer Yes I want
52. n be scanned depends on the type of film 6x4 5 1 4 frames 6x6 1 3 frames 6x7 6x9 1 2 frames Inserting Film Open the holder Slide the latch in the direction shown and open the holder Newton s Rings If the film is folded or twisted Newton s rings a radial interference pattern may appear when the film is scanned This can be prevented by placing a masking sheet in the holder as shown at right The aperture at the front of the masking sheet should match the film frame size Stickers Place stickers between frames on the Emulsion emulsion surface of the film no sticker is surface required between the first two frames The stickers can then be used to fasten the film to the masking sheet Stickers can be reused Place side with stickers down 4 Keep the Glass Clean The inner surface of the glass cover been treated to prevent interference Avoid leaving fingerprints or other stains on the glass 54 Insert film Place film base up fW 26 between the guides with the left end of the film at the film line If a masking sheet is used the start of the first exposure should be aligned with the inner edge of the masking sheet Additional film strips can be placed in the holder as space permits place the film end to end with no gaps V4 Inserting Film Use only one type of film do not place negatives in the holder with positive film First frame Be sure to align the end of the film w
53. nd Exit 41 23 Step 1 Turn the Scanner On Before turning on the scanner for the first time make sure that Nikon Scan is installed on the computer and that the power and IEEE 1394 cables are connected For information on install ing Nikon Scan and connecting the cables see Setup Wi 7 1 Turn the computer on Turn the computer on and wait for the operating system to start up 2 Turn the scanner on The status LED will blink for about two minutes while the scanner initializes The status LED will stop blinking when initialization is complete Scanner off Scanner on Status LED off Status LED blinks FA Windows 98 SE If the dialog shown at right appears the first time the scanner is connected and turned on the IEEE 1394 driver update has not been completed Update the IEEE 1394 drivers as described in Updat ing the IEEE 1394 Drivers Windows 98 SE Only The Insert Disk Dialog Rf 65 Windows 2000 Professional A Digital Signature Not Found dialog will be displayed the first time the scanner is connected and turned on following installation of Nikon Scan Click Yes to register the scanner with Windows If the Status LED Flickers Status LED on The Microsoft digtal signature affims that software has been tested with Windows and that the software has not been altered since it was te The software you are about to install does not contain a Microsoft daal signature Therefore there is no
54. ning Curled Film Curl of 10mm or less can be removed as follows 1 Unlatch the movable base Slide the latch in the direction shown 2 Flatten the film Place your fingers on the grips and slide them gently outwards Do not use force To prevent the film from sliding out of position press the holder cover lightly before sliding the grips 3 Latch the movable base Slide the latch in the direction shown Film with a curl of more than 10mm can not be scanned in the FH 869S Use the optional FH 869G glass covered film holder or the optional FH 869GR glass covered rotating film holder eu 54 56 Step 3 0pen the Scan Window The scanner is controlled from the Nikon Scan scan window Choose the application in which pictures will be displayed After scanning pictures can be displayed either in Nikon Scan or in a third party applica tion such as Adobe Photoshop The application in which pictures will be displayed after scanning is referred to as the host application Application Platform Description f Windows Nikon Scan used as a stand alone application to scan process Nikon Scan 4 Macintosh print and save images Nikon Scan used as a TWAIN source to control the scanner from a A third party application application must support TWAIN Images are Windows scanned using Nikon Scan and processed printed and saved in the third party application Third z Ir Nikon Scan plug in used to control the scanner
55. nual the SUPER COOLSCAN 9000 ED is sometimes referred to as the 9000 ED Windows XP Home Edition and Windows XP Professional are jointly referred to as Windows XP Windows Millennium Edition as Windows Me and Windows 98 Second Edition as Windows 98 SE Life Long Learning As part of Nikon s Life Long Learning commitment to ongoing product support and education con tinually updated information is available on line at the following sites e For users in the U S A http www nikonusa com e For users in Europe http www europe nikon com support e For users in Asia Oceania the Middle East and Africa http www nikon asia com Visit these sites to keep up to date with the latest product information tips answers to frequently asked questions FAQs and general advice on digital imaging and photography Additional information may be available from the Nikon representative in your area See the URL below for contact information http www nikon image com eng 2 Parts of the Scanner Front View Status LED Scanner status is indicated as follows Status LED Blinks about 1 5 x s Flickers about 5 x s Scanner status No operations in progress Film holders can be inserted or re moved Scanner busy Do not turn scanner off or insert or remove film holders Hardware or communications error Turn scanner off wait for at least 5s and turn scan ner on again Power switch Pressing this swi
56. nual provides complete information CLR on using the supplied Nikon View software to view and organize images This manual is stored on the reference CD in pdf format Trademark Information Apple the Apple logo Macintosh and Mac OS are registered trademarks of Apple Computer Inc Finder is a trademark of Apple Computer Inc Microsoft and Windows are registered trademarks of Microsoft Corporation Pentium is a trademark of Intel Corporation Digital ICE Advanced is Digital ICE Digital ROC Digital GEM and Digital DEE Digital ICE Advanced are technologies developed by Applied Science Fiction Radius ColorMatch and PressView are registered trademarks of miro displays inc Adobe and Acrobat are registered trade marks of Adobe Systems Inc All other trade names mentioned in this manual or the other documentation provided with your Nikon product are trademarks or registered trademarks of their respective holders For Your Safety To prevent damage to this Nikon product or injury to yourself or to others read the following safety precautions in their entirety before using this equipment Keep these safety instruc tions where all those who use the product will read them The consequences that could result from failure to observe the precautions listed in this sec tion are indicated by the following symbols This icon marks warnings information that should be read before using this Nikon product to prevent serious injur
57. o be scanned QU then enters exact output size in output US size area Choose this option when im ETM age must fit in space of known dimen ull sions User selects general area to be scanned then enters exact file size for final image in file size area Choose when file size is paramount for example when scanning images for electronic distribution Keep this File Size Enter the desired Height and or Width in the text boxes If Keep this Crop is selected the remaining dimension will automatically be adjusted to maintain the current crop If Keep this File Size is selected the re maining dimension and the resolution will automatically be adjusted to maintain the selected file size and the crop in the preview area will be adjusted accordingly o Curves v Curves x RGB X Au Z 1 WA o 1 00 255 FE Input Output Make adjustments to brightness contrast and color targeted to specific portions of the tone range for example this tool can be used to increase brightness in shadows color Balance v v Color Balance x Brightness 4 p Contrast 4 H gt p Red 4 rp Green 4 lo Blue 4 a 2 Adjust overall brightness contrast and color balance Unsharp Mask v v Unsharp Mask z Sharpen images by making colors more dis tinct Q LCH Editor v v LCH Editor z 255 D p M 1 00 Input Output Make adjustments to br
58. oduct While every effort has been made to ensure that the information in these manuals is accurate and complete we would appreciate having any errors or omissions brought to the attention of the Nikon representative in your area address provided separately Federal Communications Commission FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential instal lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communica tions However there is no guarantee that interfer ence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is con nected Consult the dealer or an experienced radio television technician for help Notice for customer
59. onents Complete ene installation as described in steps 8 13 E Non San Pin 4 of Installing Nikon Scan Macintosh rene o yn 17 18 73 IChecking Device Registration Windows Only The first time the scanner is connected and turned on following installation of Nikon Scan Windows will register the scanner with the Device Manager If the computer fails to detect the scanner or the scanner does not function as expected when Nikon Scan is running the computer may not have correctly registered the scanner Check that the device drivers are correctly installed 1 Make sure the scanner is connected and turned on 2 Display the System Properties dialog Windows XP Select Control Panel from the Start menu open Performance and Maintenance and Click System Windows 2000 Professional Select Settings Control Panel from the Start menu and double click the System icon Windows Me Windows 98 SE Select Control Panel from the Start menu and double click the System icon 3 Open the Device Manager Windows XP Windows 2000 Professional Open the Hardware panel and click the Device Manager button Windows Me Windows 98 SE Click the Device Manager tab 74 System Properties AE System Restore po Remote Seed Corpa Hae dvnoed J Add Hardware Wizard E4 The Add Hardware Wizard helps you install hardware Add Hardware Wizard Device Manager Ty The Device M
60. or strips of different lengths place the film at the left end of the holder and cover any open apertures with the supplied masking sheets cutting the sheet to the appropriate length if necessary When scanning one or two strips place the film in the bottom rows and the masking sheets in the top rows When scanning three strips of equal length place the film at the left end of the holder Masking sheets are not required 4 Latch the holder Press the holder closed until the latches click into place Removing Film Insert your fingers into the holes in the lower portion of the holder and undo the latches Open the holder and use the cutouts to pick the film up by its edges If the edges of the film are not accessible tilt the holder to slide the film to the hollow at the end of the lower holder r Cutouts b Masking sheets amp 59 IFH 8G1 Medical Holder The FH 8G1 can be used to scan up to three glass microscope slides of prepared tissue samples Slides must be 26x 76mm with a base 0 8 1 5 mm thick a cover no more than 25mm wide 60mm long and 0 18mm thick and a total thickness of no more than 2mm including adhesive Inserting Slides Insert the slides cover up Stop when the slide contacts the base of the clips V4 Inserting Slides Insert slides between the guides Forcing the slides onto the guides could damage the slides or clips and prevent the scanner from focusing correctly To minimi
61. or dust Failure to observe this precaution could result in explosion or fire Keep clear of foreign objects Do not place vases flowerpots cups cosmetics vessels containing chemicals or water or small metal articles on the device Should water or another foreign object enter the equipment unplug the power cable and contact an authorized Nikon service representative Continued use could result in fire electric shock or malfunction Keep out of reach of children Particular care should be taken to prevent infants from putting small parts into their mouths Should a child swallow any part of the equipment contact a physician immediately IN Use an appropriate power supply The power supply must be 50 60 Hz and 100 240V AC The power cable must comply with the safety standards of the country of use have SVT insulation or better and be more than AWG18 in thickness At voltages over AC 125V At voltages of AC 125V or less Use a plug rated for 250V 15A NEMA 6 P 15 Use a plug rated for 125V 10A A Handling the power cable and plug Do not damage modify or forcibly tug or bend the power cable place it under heavy objects or expose it to heat or flame Should the insulation be damaged and wires become exposed contact an authorized Nikon service representative for information on replacement or repair Failure to observe these precautions could result in fire or electric shock Do not handle the plug with wet hands Failure
62. panel shows how the image would appear if scanned at current settings the Natural panel the unmodified image Comparing these two views can help deter mine whether changes to settings are having the desired effect Tool Palette 1 gt Layout Tools gt Information m gt v Curves n gt v Color Balance gt J v Unsharp Mask v LCH Editor gt Digital ICE4 Advanced gt Analog Gain _ gt Scan Image Enhancer _ gt Scanner Extras aan Progress Window Preview area B 47 Provides a preview of the image prior to scan ning Any modifications to settings are visible in the Processed panel Interactive help Displays a brief tip about the control under the cursor Tool Chest ff 48 Contains tools for changing the orientation of the image and selecting the portion to be scanned choosing the dimensions and resolu tion of the scanned image enhancing color contrast and sharpness processing images to remove the effects of scratches dust fading film grain and underexposure and controlling scanner settings Progress window PE 47 Shows the status of current tasks and lists operations that have been or are about to be performed 33 34 Choose the film type Click the film type menu in the scan win dow control area and choose a film type that matches the film being scanned Use with most makes of posi tive slides and reversal film These films have a black base and th
63. pproximately 200MB Copy the easy_guide_main folder and easy_guide exe to the desktop easy guide main easy guideexe manual pdf 14 Macintosh Turn the computer on and wait for it to start up Before continuing with installation make sure that e The scanner is Nor connected No other applications including anti virus software are running e The computer satisfies the following system requirements CPU Power PC G3 or later G4 or later recommended os Mac OS 9 9 1 or later Mac OS X 10 1 5 or later P e Mac OS 9 64MB or more 256 MB or more recommended RAM e Mac OS X 128 MB or more 512 MB or more recommended A A minimum of 70 MB required for installation 200 MB or more recommended with Hard uisk an additional 200 MB Mac OS 9 or 550 MB Mac OS X of free disk space available space while Nikon Scan is running CERES ae 800 x 600 pixels or more with 16 bit color thousands of colors or more Firewire Only built in Firewire ports supported VRAE CD ROM drive required for installation For the latest information on supported versions of Mac OS see the Nikon web site listed in this manual f 2 More memory may be required depending on film type scan size resolution bit depth the number of scans performed in each session the adapter used and on whether Digital ROC Digital GEM or Digital DEE is used A system with more than the minimum amount of memory is recommended More free
64. presenta ive If the status LED blinks and then glows steadily turn the scanner off and reconnect it to the computer After waiting five seconds turn he scanner on and restart the computer If the status LED flickers when the computer is restarted try the following Disconnect all other devices using the same interface as the scanner e Reinstall Nikon scan Status LED flickers scanner connected to computer Update the IEEE 1394 device drivers Windows only Update the scanner device drivers Windows only Film is not properly inserted in holder Eject the holder and reinsert the film Scanner or holder moved during scanning Do not use the scanner in locations subject to shock or vibration Fail ure to observe this precaution could result in scanner malfunction Scan window settings require adjustment Adjust settings or use factory defaults For more information see the Nikon Scan Reference Manual Glass in optional glass covered holder is dirty Use a blower to remove dust a soft cloth to remove other stains Poor quality scans Scanner is off Turn the scanner on Scanner turned on with holder inserted Computer does not After removing the holder turn the scanner off and then on again recognize scanner Interface cable not correctly connected Turn the scanner off and reconnect the cable Computer does not meet minimum system requirements Use a system that meets the requirements 24 21 2
65. s BoE 5 e 5 Show grid e 1 Select the portion of the image that will be scanned choose a focus point or rotate and flip images Use the Zoom and Grab tools to navigate images that have been opened in Nikon Scan after scanning Information _ Information R L 440 N X G py 29 Js B We 4592 H 3490 View the width and height of the current selection and the coordinates of its top left corner The color value display shows the color of the pixel under the cursor before and after processing 48 Tool Palette 1 Layout Tools 2 r Information E Crop isl o v Curves x o I gt v Color Balance E 6 bg Unsharp Mask zj I gt v LCH Editor z zi Analog Gain w Lb Scan Image Enhancer Scanner Extras o Digital ICE4 Advanced E Crop zl Keep this Crop w 6 793 HB 12 Piel z Keep this Output Size wje 1688 C Keep this File Size 261 MBytes vf Scale 4 b i944 x Resolution 360 Pixels Inch Custom D Specify the size and resolution of the image that will result when the film is scanned Centimeters vf User selects exact area to be scanned QE then selects output size and resolution this according to how image will be used Crop Best choice in most situations a User selects general area t
66. s s onec eor e re mee e Iro Preces ER em ere Eee n EX EET PG ey 60 Removilig slides is ac 2 Soe sac n ed ne e rete ee e eer ER UE S 60 Technical Notes nn 61 Mairit nahce x ee eee me E Re A e CEDE Yt ee Ee Voc Ute naines en tien LR 62 Troubleshooting c M 63 Installing the IEEE 1394 Firewire Interface Board ssssssssssseeseseeeeeeen nennen 64 Updating the IEEE 1394 Drivers Windows 98 SE Only 65 Installing the IEEE 1394 Firewire Interface Board Installing the Device Drivers Windows Only Uninstalling NIKON Scans isa erepti Eee AP ROTE RENS este ne do PIRE REESE HET iiaa VVIFIdOWS eM EA ef ume e PRE Mess A ARR SCORES TETAS IDEAS SOSA OEE te EE ee Md Macintosh etes A A ur M LM E LTEM E ae A te UE rer Custom Install Macintosh Only enne nnne nnns ennt tnnt nnns nnns ntes ennt sinn Checking Device Registration Windows Only enne nnne ntn Specifications fire ere voee Yee EC TRE ERECT EIE UE EESTI VER Ie PER ER VETE en PH eee Pere SUPER COOLSCAN 9000 ED LS 9000 ED Supplied Filrm btelderss 4 ii eee rre Et e E ME RP Optional Film HOSS zs coi ree rre ERE CE tq esed rt pe hens hber M vi Before You Begin This chapter describes the conventions used in this manual the names of scanner parts and precautions for use Introduction EE EI 2 Pantsiof theiScantiefe e CRINE 3 Precautions forlse RM e e ne eI e E
67. s the images will be saved in the location chosen in the File Saving Options dialog Proceed to Step 9 Eject and Exit f 41 3 Nikon SUPER COOLSCAN 9000 r T E Lu Digita Digital ICE Of Scan button When scanning is complete images will be opened in image windows in the host ap plication single scans only Note that the scan window may remain open on top of the host application window to view the images it may be necessary to move the scan window Windows Macintosh M tons rie cst View image Toss Modos Help so Image window 39 Select the save command To save the image in the active window select Save or Save As from the File l H E menu in the host application VW 30 If Open Creo m Nikon Scan is being used as a stand 2 E alone application under Windows the KES image in the active window can also be ORE saved by clicking the Al Save button in the toolbar 3 Save the image After navigating to the desired location enter a name for the image and choose a file format Click the Save button to save the image to disk Repeat steps 2 and 3 until all images have been saved Typical Save As dialogs Save As ied Ea Save NikonScan Save in 9 Desktop z idm Save As Untitled 1 tif Emy Documents VU AL ou Where Hi Desktop My Recent amp 9My Network Places Documents File Type TIFF
68. s in the State of California Nikon LS 9000 ED C Tested To Comply With FCC Standards FOR HOME OR OFFICE USE CAUTIONS Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Nikon Corporation may void the user s authority to operate the equip ment Interface Cables Use the interface cables sold or provided by Nikon for your equipment Using other interface cables may exceed the limits of Class B Part 15 of the FCC rules WARNING Handling the cord on this product will expose you to lead a chemical known to the State of California to cause birth defects or other reproductive harm Wash hands after handling Nikon Inc 1300 Walt Whitman Road Melville New York 11747 3064 U S A Tel 631 547 4200 Notice for customers in Canada CAUTION This class B digital apparatus meets all require ments of the Canadian Interference Causing Equip ment Regulations ATTENTION Cet appareil num rique de la classe B respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada iii Notice Concerning Prohibition of Copying or Reproduction Note that simply being in possession of material that has been digitally copied or reproduced by means of a scanner digital camera or other device may be punishable by law Items prohibited by law from being copied or reproduced Do not copy or reproduce paper money coins se
69. slides with mounts 1 0 3 2 mm thick It is equipped with two apertures a smaller aperture for 6x4 5 or 6x6 slides and a larger aperture for 6x7 6x8 and 6x9 slides V4 Do Not Mix Positive and Negative Film Do not place mounted negatives in the holder with positive slides Inserting Slides Insert the slides between the guides The slides should be oriented to match the ap ertures in the holder and the reflective film base should be up 9 26 Stop when the slide contacts the base of the clips V4 Inserting Slides Insert slides between the guides Forcing the slides onto the guides could damage the slides or clips and prevent the scanner from focusing correctly To minimize resistance try inserting slides at a slight angle Removing Slides Slide the mounts out from under the clips that hold them in place V4 Do Not Use Force Do not use force when removing slides Fail ure to observe this precaution could damage the clips Do not lift the slides up until fully removed from the clips 7 Do Not Store Slides in the Holder Guides Thumbnails displayed in order shown Direction of insertion Leaving slides in the holder for extended periods could damage the clips holding the slides in place 53 FH 869G Glass Covered Holder for Medium Format Film The FH 869G is used to scan medium format film 120 220 2 or Brownie and 59x 82mm electron microscope film The length of the film strip that ca
70. spaces here 1 sRGB 2 Bruce RGB 3 NTSC 1953 4 Adobe AGB 1998 5 CIE RGB amp Wide Gamut RGB 7 Wide Gamut RGB compensated 1 gives you the moat vivid color reproduction and itis recommended as the standard color space lor web authoring However t may be too saturated in Viu fe ree Sel amie eot EHE Ji ls en HG represent values between these two extr Dome me be OK bul Onrse 1353 O Adobe AGB I 998 OE RGB O Wide Gamut RGB O Wide Garut RGB Compensated imple displayed using the selected color space profile Asa ff you think hat al eee ie press the button Too Light 13 1 Click Finish Nikon Scan 4 Setup Nikon Scan 4 Setup Complete Nikon Scan 4 Setup has successhuly installed Nikon S can 4 0 13 Restart the computer Click Yes to restart the computer Once Less the computer has restarted take a few TU SEEMS CLE EE ETL minutes to view the ReadMe file which C may contain important information that could not be included in this manual Viewing the Easy Scanning Guide Windows Insert the Nikon Scan 4 Reference Manual Easy 33S Scanning Guide CD and double click the easy RSS ESRI fc guide exe icon The Macromedia Flash Player O Ps pre fa will start and a language selection screen will be displayed click the appropriate link to view the guide in the desired language The Easy Scanning A Guide can also be copied to the computer hard disk for ease of reference total size a
71. t application if multiple frames are selected in the thumbnail drawer a scan will be per formed for each frame and the resulting im ages will be opened in separate windows The Thumbnail Drawer Tab Click this tab to open the thumbnail drawer If multiple frames are selected the selected images can be scanned in a single batch This is called a batch scan The Preview Area Selected frames are previewed in this area Click the Natural and Processed tabs for a quick before and after comparison showing the effect of changes to settings in the Tool Chest The Natural panel shows the image before processing the Pro cessed panel the image as it would appear when scanned at current settings The Progress Window LSCAN 9000 ED 1 00 IFEE1394 Natural Processed tabs Progress Window Acquiring scan Sees Stop Performing Scan Queue Log The progress of preview and scan operations is shown in this window The current task ac quiring thumbnails preview or scanning is shown at the top of the window Tasks that have yet to be performed are listed in the Queue panel completed tasks in the Log panel To stop the current task click Stop 47 Mhe Tool Chest To display or hide the Tool Chest click the Tools button in the control area of the scan window For more information see the Nikon Scan Reference Manual on CD Layout tools _y Layout Tool
72. t the left end of the holder and cover any open apertures with the supplied masking sheets cutting the sheet to the appropriate length if necessary When scanning a single strip place the film in the bottom row and the masking sheet in the top row When scanning two strips of equal length place the film at the left end of each row Masking sheets are not required P Position the film Close the holder without latching it and check that the film is correctly aligned If necessary insert a pen or other pointed object into the per forations and slide the film until the frames are aligned with the apertures The perforations can be accessed through the cutouts at the left end of the holder Cutouts V4 Positioning Film Care should be taken to avoid damaging the perforations when positioning the film Do not attempt to position the film while the holder is latched Failure to observe this precaution could damage the film 25 Latch the holder Press the holder closed until the latches click into place Proceed to Step 3 Open the Scan Window yn 30 27 28 FH 835M Holder for 35 mm Slides The FH 835M can be used to scan up to five 35 mm slides with mounts 1 0 3 2 mm thick Slide the mounts into place between the guides short side first and with the reflective film base up the matte emulsion surface down 81 26 Stop when the slides contact the base of the clips Arrow Thumbnails displayed in order sho
73. tch turns the scanner on and off Eject button Pressing this button ejects film holders from the scanner Holder slot Holders for various types of film can be inserted in this slot A flap prevents the accumulation of dust inside the scanner when the device is not in use Rear View AC connector EEE 1394 Firewire connector The female end of the AC power cable The IEEE 1394 interface cable connects plugs into this connector here IPrecautions for Use Observe the following precautions to ensure that the scanner always produces the best pos sible results 74 Check the status LED Do not turn the scanner off or insert or remove film holders while the status LED is blinking Do not use other IEEE 1394 Firewire devices or turn them on or off while the status LED is blinking Do not connect or disconnect USB or IEEE 1394 Firewire cables while the status LED is blinking Do not operate camera control software for digital cameras connected via USB while the status LED is blinking 74 When the scanner is not in use Remove the film holder and turn the scanner off when not in use Connecting the scanner Connect the scanner directly to the computer The scanner may not function as expected when con nected to an IEEE 1394 hub or adapter The scanner may not function as expected when used together with other IEEE 1394 devices Should the scanner not function as expected use the scanner with all other
74. te dialog shown at right Enter the administrator name and password and click OK Read the license agreement Click Accept to accept the agreement and continue installation o Select Language Welcome to the world of Nikon Digital photography Please select a language from the choices below Language English Di ZO Install Center Software Customer Support t Authenticate Nikon Scan Installer requires that you type your j passphrase f mime Password or phrase DE License Nikon Corporation License Agreement D This Nikon License Agreement Agreement is a legal agreement between you either an individual lor single entity and Nikon Corporation Nikon setting forth the terms and conditions for your use lof the Nikon software accompanying this Agreement which includes computer software and may nclude associated media printed materials and online or electronic documentation SOFTWARE By installing downloading and or using this SOFTWARE you indicate your acceptance of this Agreement and are agreeing to be bound by the terms of this Agreement If you do not agree to the terms of this Agreement you are not authorized to install download or use this SOFTWARE Promptly return within fifteen 15 days from the date of delivery the package to the authorized Nikon Dealer where you obtained it for a full refund This license is not a s
75. the Language Selection Dialog Is Not Displayed If the language selection dialog does not appear after the Nikon Scan CD is inserted 1 Double click the My Computer icon on the desktop 2 Right click the CD ROM drive containing the Nikon Scan CD 3 Choose AutoRun from the menu that appears 2 Click Install The Install Center dialog will be dis Emmm played Open the Software panel and Click Install Software Customer Support 3 Click Next Nikon Scan 4 Setup E Welcome to the InstallShield Wizard for Nikon Scan 4 The als kde Wizard val Fal Nkon Scen 4 on your er To continue cick Ne Read the license agreement Click Yes to accept the agreement and continue installation Nikon Scan 4 Setup License Agreement t Please read the following license agreement carefully Press the PAGE DOWN key to see the rest of the agreement Nikon Corporation License Agreement uo codec ce CE ea Bees individual or single entity and Nikon cael tinker el forth the terr PE DL Es Galella asta ich includes computer software and may include associated media printed materials and Ra o eechone decuneraten SOFTWARE By instaling downloading and or using this SOFTWARE you indicate your acceptance jy Da you accept all the terms ofthe preceding License Agreement lf pou select No the setup wil close To install Nikon Scan 4 you must accept thir agreement lt Back 11 Choose a destination folder
76. the Windows Update Web site at hitp windowsupdate mictosoit com to ses if one is ay Do you want to continue the installation Ye phe More Info Device Registration Windows 2000 Professional A Digital Signature Not Found dialog will also be displayed the first time the scanner is connected and turned on following installation of Nikon Scan Click Yes to register the scanner with the system Windows XP Windows Me Windows 98 SE Once Nikon Scan has been installed the scanner will automatically be registered with the system the first time the scanner is connected and turned on Create a shortcut optional Click Yes to create a shortcut to Nikon Scan on the desktop Click No to pro ceed without creating a shortcut Settings File Extensions If other Nikon imaging software is in stalled the dialog shown at right will be displayed Click Yes to associate Nikon Scan with settings file extensions such as nca and ncv Click Use Wizard recommended Click Use Wizard to choose an RGB color space profile with the help of the Color Space Wizard recommended The selected color space profile can be changed in the Nikon Scan Prefer ences dialog after installation Question v Do you want to create a shortcut for Nikon Scan 4 on your desktop C9 jJ Would you like to associate the following files extensions with Nikon Scan nca color balance nec crog ncv curves num Unsherp Mask set
77. to restart my computer now O No wil estat my computer later Remove any disks from their drives and then click Finish to complete setup When installing or uninstalling Nikon Scan under the above operating systems log in as the Computer administrator Windows XP or Administrator Windows 2000 Professional 70 Macintosh 1 Quit all applications 2 Insert the Nikon Scan CD into the CD ROM drive A Nikon Scan 4 CD icon will appear on y the desktop Double click the icon to sew seu 2 open the Nikon Scan 4 window Double click the Welcome icon in g the Nikon Scan 4 window Choose a language o a A language selection dialog will be Welcome to the world of Nikon Digital photography displayed Select a language and click Mini EE Next Language EE RB gt W 5 Start the installer The Install Center dialog will be dis PES Install Center played Open the Software panel and Nikon 25 click Easy Install 34 gt Software Customer Support Y Authenticate Mac OS X Only diese Nikon Scan Installer requires that you type your Clicking Easy Install in the software a e panel displays the Authenticate dialog F 5 shown at right Enter the administrator Name Password or phrase name and password and click OK aue 6 Click Accept The license agreement will be displayed License Click Accept License Agreement T
78. uceecdste secduceepintivasdazese td i MARN EET ch i CAUTIONS SR ee Ne a S E TR ii Notices dee iii IDBICRCIUNCMEE 1 INGO UCEION t n es 2 Principal Feat res cssc eerie ce Hee EE e n c ea un aet e see cas E edis 2 Parts of the SCatifier e Reese ee de srr manne EH CER NA De rends de Reader en vas lebuacduveepaetbves CERO TRES 3 dizi nDnrRnldipe 5 E M 7 Setup and Scanning Guide Installing NIKOn Scal eerie trente etr A nene ee ERR e eer nee niet rere WINDOWS RI E m MiEtelodt T M Installing RAS T8 Dno RR Step 1 Choose a Location Step 2 Connect the Power Cable Step 3 Connect the IEEE 1394 Cable cce ee eee a 22 Basic SCANNING E 23 Step 1 Turn the Scanner ON vcscscccsscvscecsesccsectvssccseceessevseccensteesscevaeceuedonsevetussecusseueseavvactesbievsseescees 24 Step 2 Place Film in the Holder iii 25 Step 3 Open the Scan Window iii 30 Step 4 Insert the Holder iiiter teh HR tintin lent Ce esten 32 Step 5 Choose a Film Type and Color Model issus 33 gd n re 35 Step 7 Select a Crop
79. umbnails and display them in the thumbnail drawer drawer 3 Select frames Select the frame to be scanned by click Ex Nikon SUPER COOLSCAN 9000 ED 1 00 IEEE1394 ing the associated thumbnail or frame IN number selected frames are indicated J Scroll bar by a green border To select multiple 5 frames hold down the Ctrl Windows or command Macintosh key while click ing each frame in turn or hold down the shift key and click to select two Selected frame images and all frames between them To view frames not currently visible in the thumbnail drawer use the scroll bar or enlarge the drawer by dragging the handle at its lower right corner Handle CX The Thumbnail Display If the wrong film type or frame size is chosen when thumbnails are generated the thumbnail display will not reflect the contents of the film Click the m button in the thumbnail drawer to hide thumbnails and then select the correct film type or frame size Click the Sis button to view the new thumbnails 35 Click the Preview button A preview will be displayed in the preview area Nikon SUPER COOLSCAN 9000 ED 1 00 IEEE1394 E Nikon SUPER COOLSCAN 9000 ED 1 00 IEEE1394 DER mj 7 ee Frevw ca A peine scan ofthe mage con be denied Preview button If multiple frames are selected additional frames can be previewed by clicking the thumbnails in the thumbnail drawer Rotating and Flipping Images The
80. unter clockwise Adjust the angle us ing the marks on the front of the holder as a guide each mark is equivalent to 1 and then tighten the locking screw Ul Locking screw Removing Film Insert your fingers in the depressions and Depressions pick the film up by its edges Keep the Glass Clean The inner surface of the glass cover been treated to prevent interference Avoid leaving fingerprints or other stains on the glass 57 IFH 816 Holder for 16 mm Film The FH 816 is used to scan up to three strips of 16 mm film Each strip can be from one to twenty frames in length Inserting Film 1 Open the holder Insert your fingers through the holes in the bottom half of the holder and undo the latches then open the holder Latches 2 Insert film Place film in the holder base up GY 26 Align the first frame in each strip with an aperture at the left end of the holder V4 Use Only One Type of Film Do not place negatives in the holder with positive film gt Thumbnails 4 displayed in amp order shown insertion Inserting Film and Masking Sheets Do not place film or masking sheets so that they protrude from the holder or overlap the film guides Failure to observe this precaution may cause the holder to jam in the scanner Digital ROC Digital GEM and Digital DEE fff 50 These functions can not be used with 16 mm film 58 Insert masking sheets When scanning one or two strips
81. ve on scanner or computer IEEE 1394 Firewire terminal above at left 7 Connecting the Scanner Do not connect or disconnect IEEE 1394 cables while Nikon Scan is starting or after it has started The scanner may not function as expected when used with other IEEE 1394 devices Should the scan ner not function as expected use the scanner with all other IEEE 1394 devices disconnected Do not connect two or more scanners to the computer simultaneously Do not connect or disconnect USB or IEEE 1394 interface cables or operate camera control software for digital cameras connected via USB while the scanner status LED is blinking After disconnecting the cable wait a few seconds before connecting it again Computers with Four Pin Connectors The supplied IEEE 1394 cable can not be connected to computers with a four pin DV connector Use a cable with one six pin and one four pin connector or a six to four pin adapter 22 Basic Scanning This chapter details the steps involved in making a simple scan Step 1 Turn the Scanner On 24 Step 2 Place Film in the Holder 25 Step 3 Open the Scan Window 30 Step 4 Insert the Holder 32 Step 5 Choose a Film Type and Color Model 33 Step 6 Preview 35 Step 7 Select a Crop 37 Step 8 Scan and Save 39 Step 9 Eject a
82. whose computer is not equipped with a compatible IEEE 1394 interface must install the supplied IEEE 1394 Firewire interface board Macintosh users should note that beige G3 computers are not equipped with a built in Firewire interface To install the board follow the steps below Operating system Installation 1 Install the interface board The board device drivers will be 66 WindowsXP installed automatically when the computer is turned on Windows 2000 Professional Confirm that the board is correctly registered in the Windows 66 67 Windows Me Device Manager 1 Update the IEEE 1394 drivers 65 Windows 98 SE 2 Install the interface board 66 3 Install the drivers for the interface board 68 69 Mac OS Install the interface board 66 Computers Without an Empty Full Sized PCI Slot The supplied IEEE 1394 board can only be installed in a full sized PCI slot It can not be installed in laptop computers or in computers with a low profile PCI slot For information on other approved boards and PCMCIA cards see the Nikon web site for your area xy 2 64 Updating the IEEE 1394 Drivers Windows 98 SE Only Users of Windows 98 SE must update the IEEE 1394 drivers provided with Windows before they can use the scanner This update is required regardless of whether an IEEE 1394 interface is already installed or the user is installing an IEEE 1394 interface for the first time 1 Insert the Nikon Scan CD Holding down the shift key to pr
83. wn Guides Direction of insertion V4 Inserting Slides Insert slides between the guides Forcing the slides onto the guides could damage the slides or clips and prevent the scanner from focusing correctly To minimize resistance try inserting slides at a slight angle Be sure a Slide is inserted in the first slot Leaving the aperture at the left end of the hold er uncovered could cause scanning errors or interfere with accurate color reproduction Proceed to Step 3 Open the Scan Window fg 30 FH 869S Holder for Medium Format Film The FH 869S can be used to scan medium format 120 220 2 or Brownie film and 59 x 82 mm electron microscope film The length of the film strip that can be inserted in the holder depends on the type of film 6x4 5 1 4 frames 6x6 1 3 frames 6x7 6x9 1 2 frames FK Open the holder Undo the latches and open the holder AD Insert film Place film in the holder with the reflec tive film base up matte emulsion sur face down V 26 and with the end of the film against the stops Thumbnails displayed in order shown Direction of insertion V4 Inserting Film Use only one type of film do not place negatives in the holder with positive film Be sure the end of the film is flush with the stops A gap between film and stop could interfere with accurate color reproduction EB Close the holder Close the holder pressing the covers down until they latch Scan
84. y Unplug when not in use Turn off and unplug the device if it will not be used for an extended period Failure to observe this precaution could result in fire Handling the power cable and plug Do not place the power cable in the vicinity of a stove or heater The insulation could melt resulting in fire or electric shock e Unplug the cable by pulling on the plug never on the cable itself Failure to observe this precaution could damage the cable resulting in fire or electric shock Do not plug the power cable into an extension cord or multi outlet adapter as this could cause fire or malfunction Ground the equipment e The outlet into which the power cable is plugged must be grounded Failure to ground the power supply could result in electric shock Do not ground the outlet to a gas or water pipe or a dedicated telephone system earth connector Failure to observe this precaution could result in fire or electric shock Notices No part of the manuals included with this product may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form by any means without Nikon s prior written permission Nikon reserves the right to change the specifications of the hardware and software described in these manuals at any time and without prior notice Notice for customers in the U S A Nikon will not be held liable for any damages resulting from the use of this pr
85. y or death This icon marks cautions information that should be read before using this Nikon product to prevent damage to the equipment or injury to yourself or to others WARNINGS Do not disassemble or modify The interior of the device contains areas of high voltage Removing the casing could result in fire or electric shock Contact an authorized Nikon service representative for inspection or repair Do not modify Modification could result in fire or electric shock N Do not touch exposed parts Should the product break open as the result of a fall or other accident do not touch the exposed parts Unplug the power cable and take the product to an authorized Nikon service representative for inspec tion Unplug in the event of malfunction e Should the equipment start to smoke or produce an unusual noise or smell turn the device off imme diately and unplug the power cable Continued use could result in fire or electric shock Wait for the equipment to stop smoking and then contact an authorized Nikon service representative for informa tion on replacement or repair Do wor attempt repairs yourself as this would be extremely dangerous ein the event of damage to the equipment turn the device off at once and unplug the power cable then contact an authorized Nikon service representative for information on replacement or repair Continued use could result in fire or electric shock Do not use in the presence of flammable gas
86. ze resistance try inserting slides at a slight angle Removing Slides Slide the samples out from under the clips that hold them in place V4 Do Not Use Force Do not use force when removing slides Fail ure to observe this precaution could damage the clips Do not lift the slides up until fully removed from the clips V4 Do Not Store Slides in the Holder Guides Thumbnails displayed in order shown Direction of insertion Leaving slides in the holder for extended periods could damage the clips holding the slides in place Do Not Use Digital ICE Digital ROC Digital GEM or Digital DEE 50 Noise may appear in images scanned with Digital ICE Digital ROC Digital GEM or Digital DEE Scanning 35 mm Slides The FH 8G1 can also be used to scan 35 mm slides Do not mix 35 mm slides with microscope slides 60 Technical Notes This chapter lists scanner specifications and provides information on maintenance troubleshooting and in stalling the supplied IEEE 1394 interface board Maintenancez eere eren eI E Troubleshooting tee RUM TNR E Installing the IEEE 1394 Firewire Interface Board Uninstalling Nikon Scan seen Custom Install Macintosh Only Checking Device Registration Windows Only SpecificatiOris me e ETT 61 Maintenance Storage When the scanner is not in use eject the film holder and turn the scanner off If the device will not be used for a prolonged per

Download Pdf Manuals

image

Related Search

Related Contents

Data Sheet  Produire de grandes quantités de cellules : guide de  USER MANUAL V.2  MODE D`EMPLOI  PS Printer Kit-AY1 Service Manual  manual de usuario león cupra r  Cai OS User manual  MSI Wind Box III Plus  ESPAÑOL  Notebook Belinea b.book 3.1 Manuale d`uso  

Copyright © All rights reserved.
Failed to retrieve file