Home

Nikon 10x44 User's Manual

image

Contents

1. In the event that you should require service for your Nikon RIFLESCOPE in case of U S A market please send it directly to A Rifl esco p e MONARCH X Nikon Scope Service 841 Apollo Street Suite 100 El Segundo CA 90245 4721 2 5 1 0x44 SF 1 800 Nikon SV In case of outside U S A please bring it to dealer from which you purchased it 2 5 1 0x44 SF IL 4 16x50 SF Manufacturer NIKON VISION CO LTD 3 25 Futaba 1 chome Shinagawa ku Tokyo 142 0043 Japan Tel 81 3 3788 7697 Fax 81 3 3788 7698 Printed in Japan 506B 72 1Y 1E Instruction manual E Congratulations on your choice of a Nikon RIFLESCOPE Your new scope is the finest example of Nikon s rugged and durable construction and precision bright optics important qualities for a serious shooter s riflescope Whether you use your scope for hunting or for target shooting the procedure for mounting is identical You should acquire a set of high quality steel mounting rings which have a diameter of 30 mm Follow the ring manufacturer s instructions for mounting procedures After mounting the scope on your rifle follow the procedures for reticle alignment Caution 1 Do not look at the sun through the riflescope It will permanently damage your eye This precaution applies to all optical devices such as cameras and binoculars 2 The riflescope is effectively sealed against moisture and dust You may use your scope safely either in the rain or in dusty climates To preserve t
2. ain unpatterned wall Loosen the lock ring Non illuminated Reticle model aA MNN Turn the eyepiece adjustment counter clockwise and then turn it clockwise until the reticle appears sharp Non illuminated Reticle model Lock Ring Eyepiece Adjustment Eye Relief Fig 3 2 Fig 3 3 Non illuminated Reticle model Nikoplex Reticle Miliradian Dot Reticle Finally without moving the eyepiece adjustment turn the eyepiece lock ring as Fig 3 4 to end so that the eyepiece adjustment will be firmly locked f E Eeypiece Adiustment The lock ring must be firmly tightened to ensure an air tight seal A E x LUEN 4 Illuminated Reticle model Eyepiece Adjustment Eye Relief Lock Ring 3 Magnification The riflescope 2 5 10x44 SF have a variable magnification from 2 5 to 10x 4 16x50 SF from 4 to 16x To change powers just rotate the power selector ring until the desired magnification appears adjacent to the power index dot 4 Adjustment and zero setting of the riflescope Sighting through the riflescope align the rifle with your aiming point on the target and shoot a trial round If the bullet does not hit the aiming point adjust the elevation and windage as follows If the bullet hits under the aiming point turn the elevation adjustment counter clockwise in the direction of the arrow marked UP for up as in Fig 3 5 If the bullet hits high turn adjustment clockwise in the opposite direction of the arrow mark
3. ed UP for down If the bullet hits to the right of the aiming point turn the windage adjustment clockwise in the opposite direction of the arrow marked R for left as in Fig 3 5 If the bullet hits to the left of the aiming point turn adjustment counter clockwise in the direction of the arrow marked R for right After the reticle has been adjusted to the point of impacts with the grip held with your fingers to avoid shifting of the aligned grip turn the four grip screws around the grip counterclockwise with Allen wrench Then lift the grip up and align the 0 with the index mark And by securing the grip with your fingers to avoid shifting of the grip turn the grip screws clockwise with Allen wrench until the grip in firmly secured Fig 3 6 Note The windage and elevation scales of the riflescope 2 5 10x44 SF and 4 16x50 SF are calibrated in division of 1 4 minute of angle with a click at intervals of 1 4 minute of angle one division When adjusting the reticle to the point of aim remember that one minute of angle equals approximately one inch 2 54 cm at 100 yards 91 44 m Therefore if the impact point is two inches 5 08 cm low and one inch 2 54 cm right at 100 yds 91 44 m Parallax Setting you should adjust two minutes of angle up one minute of angle left In case of 50 yds 45 72 m Parallax Setting the adjusting value is double In case of 75 yds 65 58 m Parallax Setting is 1 5 times 5 Adjustable objecti
4. he appearance of the scope we suggest that it be dried and cleaned prior to storage Use a soft cloth for cleaning metal surfaces and use photographic lens tissue to clean the scope s lenses When setting the reticle for hunting you should determine your standard range and then adjust the reticle based upon that target distance For targets which vary from that standard distance you may simply adjust the position of the reticle in relation to your target or you may wish to use the procedure for trajectory compensation It s up to your personal prefer ence We hope that you will enjoy your new Nikon RIFLESCOPE for many years to come Enjoy using it and above all always follow safe shooting procedures ITEM SUPPLIED Menmi Eyepiece cap Battery 3V Lithium battery CR2032 Objective cap E Dual illuminated Reticle model only 2 5 10x44 SF IL 2 5 10x44 SF 4 16x50 SF D 2d 4 QO Q Objective Lens Eyepiece Lens Elevation Adjustment Windage Adjustment Eyepiece Lock Ring Eyepiece Adjustment Power Index Dot Power Scale Power Selector Ring Side Focus Adjustment Ring Side Focus Distance Mark Distance Scale Index Rheostat Intensity Dial Battery Compartment Cover Hood 2 Specifications 3 Instructions Actual Magnification 9 5 10X 4 16X iactive Di Length 7 Your Nikon Monarch X 2 5 10x44 SF Dual Illuminated Reticle is powered by one 3V lithium battery CR2032 or equivalent When
5. ve The riflescope 2 5 10x44 SF and 4 16x50 SF can be more precisely focused within the range of at least 50 yds 45 72 m infinity by rotating the Side Focus adjustment ring Parallax can be eliminated and sight alignment will be accurate Maintenance 1 Lens cleaning To remove dirt of fingerprint soak gauze of lens cleaning paper silicon free paper sold at camera shop with a small quantity of absolute alcohol available from drugstore and lightly wipe off Wiping with handkerchief of leather is not recommended as it is likely to damage the lens surface Dust may scratch the lens surface or corrode the lens Brush dust off using a Soft oil free brush 2 Scope Exterior Use a soft dry cloth to wipe off any dirt or finger prints that might accumulate It is not necessary to oil the scope s surface 3 Windage Elevation Adjustments These adjustments are permanently lubricated Do not attempt to lubricate them Cover with caps supplied except when adjusting to keep out dust and dirt 4 Eyepiece Ajustment This adjustment is permanently lubricated Do not attempt to lubricate 5 Power Selector Ring No lubrication is required on the power selector ring Do not loosen or remove screws in power selector ring
6. your reticle grows dim or not light at all you Exit Pupil Weight need to replace the battery How to replace battery mean Be a 1 Hold the rheostat intensity dial tightly and turn the cover with coin counter clockwise CAUTION When installing batteries make sure the firearm is unloaded Use safe firearm handling practices at all time 2 Take out the old battery and put one 3V Lithium Battery into the compartment Be sure side to be up To T a aa l aerou 3 Put the cover back and turn it clockwise with coin until the cover in firmly secured Reticle Intensity Adjustment sa ane elevator Sc Windau 4 Turn the rheostat intensity dial to the desired color red or green and intensity OFF to 5 6 steps Green color and Red color Parallax Settings at least 45 72 00 at least 45 72 00 12 19 3 05 40 10 6 Outside Diameter of Eyepiece un Construction WATER PROOF Nitorogen Gas moa minute of angle Deviation is 27 8mm at 100m 1in at 100 yds 25 4mm at 91 44m at least 50 00 at least 50 00 Tube Diameter mm 2 Focusing Look through the eyepiece with your eye positioned about 10cm 4 in away from the eyepiece lens Fig 3 1 and you will see the Nikoplex reticle Fig 3 2 or Milliradian Dot reticle Fig 3 3 Be sure your eye is positioned within proper alignment and proper eye relief otherwise the view will black out Point the objective end of the scope at the sky Do not point at the sun or at a pl

Download Pdf Manuals

image

Related Search

Related Contents

John Deere - Peg-PeregoParts.com  miniHomer User's Guide  KB6600 Series Programmable Keyboard User`s Manual  取扱説明書の表示  Gauss manual: preface  XRP9710EVB-DEMO-1 - Exar Corporation  BTW152 - maho-trading  „Top Juicer“ - Bartscher GmbH      

Copyright © All rights reserved.
Failed to retrieve file