1. repair center Please Note Never service your ACP 1300H portable air conditioner by yourself If your unit needs to be repaired please contact your NewAir dealer or a professional repair center for assistance 14 5 Electric Diagram CONTROL PANEL AC SOURCE 15 6 Technical Specifications 1200004 18000 MAK Power Supply 120V 60Hz Sees 1250W 10 8A Consumption Dehumidifying 950W 8 2A 1000W 8 7A Water Tank Capacity Liters Temperature Set Range 61 F 88F 5 Please Note The cooling capacity of the unit may be affected by several factors such as the height of the ceiling the quality of insulation number of windows etc 16
2. ACP 1300H Portable Air Conditioner Owner s Manual Please read all instructions carefully before operating Contents 1 Safety Instructions CD WARNING i ccacacsncccssedcsscccsesandceasedesscscasestandsodeasbiadendverbiddsrendcetecs 2 2 PRECAUTIONS His csecsceccsccaesesaidsadaesetadsecndsstadseondsptnidssonidspitieseeadseszesyadite 3 IY MAMONA OO si scsccisaccpsseiscavcsdavcssdesssansssngcodsssadsvendsssndssoodssexestends 4 2 Parts List 1 ACP 1300H Unit and ACCOSSONOS irsicirorsirisoinisssisieiarieriaaea 5 2 CONTO POTET caa AEAEE seid tnidey deities tudes eaea ties 6 3 REMOte COMthOl araa aA T 3 Operating Instructions 1 Operating the ACP 1300H for the First Time Operating Modes ANG THEMOS tat sc a 8 2 Setting the WMC RAA ITTI TTT 9 S Adjusting the AOW sci csdicaccicassisaveiasssiasssiezesdesrerebesdededeapsiansess 9 4 Installing the Battery for the Remote Control 5 6 5 Emptying the Auxiliary Water Tank 6 Setting up the Exhaust Hose 4 Troubleshooting TIPE iiciccisiccisisctasscisivecessscetsecedsscedsscessscassetassscessetes 15 5 Electrical Diagram iiinis asirini niria a ENA ANR NEA 16 6 Electrical SpeEcification sssini nR ARa 17 1 1 Safety Instructions Warning Connect the ACP 1300H s plugintoan Do not turn off the power supply by appropriate power outlet pulling the power cord use the On Off power button st Ee Be careful not
3. F To set the temperature press the Temperature button until the desired temperature is displayed The air conditioner will now cool the room to that temperature After five seconds of setting your desired temperature the display will then revert back to displaying the current room temperature 4 To adjust the fan speed press the Speed button This will allow the ACP 1300H to cycle through the High Medium and Low speed options Low Mid ew High 5 To turn off the unit press the Off button The air conditioner will cease operation and a tone will sound 6 1 For fresh air press the Fresh Air button while the unit is running This will then engage the built in ion generator Please Note While in dehumidification mode the unit will automatically set the fan speed to Low The ACP 1300H will not allow fan speed adjustments nor will adjusting the temperature affect the unit s operation In addition while in fan mode adjusting the temperature will not affect the unit s operation If the ACP 1300H is in standby mode the remote control s memory function will turn on Your settings will be stored in the unit s memory and when used next it will operate according to the last saved settings only the timer function will need to be reset if you are using this function 3 Operating Instructions Setting the Timer Function To set the timer function press the Timer button and enter the time that you
4. sliding glass door cannot be used a custom opening through a wall or ceiling can be cut out in order to facilitate the exhaust hose S Sdo Please Note ae The hot air must be exhausted in order for the unit to produce a cooling effect When the ACP 1300H is notin use safely store away the exhaust hose ina clean dry place 12 3 Operating Instructions Exhaust Hose 1 The exhaust hose can extend from 1 8 feet to 6 5 feet The shorter the hose the better the cooling effect 2 The hose should be as straight as possible as sharp or unnece ssary bends in the hose will prevent effective airflow This will subsequently result in overheating and possible shut down of the unit 3 The length of the exhaust hose should not be extended past 6 5 feet Replacement hoses are available for purchase through your NewAir vendor We also recommend that you use only certified NewAir re placement parts 4 Troubleshooting Troubleshooting Your ACP 1300H Portable Air Conditioner Before investing in repairs check to see if any of the following apply to you Problems Possible Causes Suggested Solutions The unit doesn t work There could be power trouble 1 The power cord is not plugged in 2 The circuit breaker has been tripped 3 There is a problem with the socket or outlet 4 Either the power cord is damaged or the fuse needs to be rep
5. to damage the power Donotusea power strip or an extension cord and do not operate the ACP 1300H cord if the cord appears to be damaged iN Before operating the ACP 1300H To avoid injury keep fingers and foreign make sure your hands are clean and dry objects out of the unit Make sure the air conditioner s ground If you notice smoke or an odd odor coming wire is connected from the ACP 1300H turn the unit off and disconnect the power plug V Baw If problems persist or if the unit malfunctions please contact your NewAir dealer or a professional repair center 1 Safety Instructions Precautions e Leave the ACP 1300H in an upright position for at least two hours before operating The unit must be installed in accordance with national and local wiring regulations The ACP 1300H s supply cord requires a Y type attachment If the supply cord is damaged it must be replaced by the manufacturer an authorized service agent ora qualified repair professional in order to avoid further damage to prevent voiding the warranty and to avoid bodily injury Never operate the ACP 1300H in an area where flammable gasses or chemicals are present To prevent electromagnetic interference place the unit at least three feet away from radios or televisions When connecting or disconnecting the power cord hold the plug itself never p
6. would like the unit to shut down You will then have the option of setting the time for the unit to resume function ranging from half an hour to 12 hours in half hour increments You can also exit the timer function at that time While the unit is in standby mode you can also set the operation times by pressing the Timer button Enter the time in which you would like the air conditioner to begin operating and you will then be able to program the time at which you want the unit to go back into standby mode ranging from half an hour to 12 hours in half hour increments You can also exit the timer function at that time Note While in the set time frame the air conditioner will display a countdown of the remaining time until the next mode is initiated To adjust the airflow if you would like to have the airflow oscillated from the ceiling to the floor press the Oscillation button on the remote control Right to left airflow can then be set by manually adjusting the louvers Please Note When turning off the unit VFD indicators will appear Off until the sweep shuts down 3 Operating Instructions Battery Installation 1 Open the battery compartment by sliding down the battery cover panel 2 Remove and discard old batteries replace with new batteries 3 Replace the battery panel back onto the remote M Remote Control Panel Fi Cover Panel La TF Please Note 1 The polarity of the batterie
7. Please Note Not all controls will require adjustment as some controls may be designed for other NewAir models 2 Parts List Remote Control 3 i 3 Are 15 4 S gael 16 5 Wing Wind 18 f 5 19 8 veg a Speed 20 9 Tne on off p 6 21 10 Ls CUB n 12 1 Oscillation Window 2 Cooling Icon 3 Auto Mode Icon 4 Output Icon 5 Time Display 6 Operation Icon 7 Oscillation Button1 8 Mode Button 9 Temperature Button 10 Set Time Button 11 Battery Compartment 12 Battery Cover 13 Fan Icon 14 Dehumidification Icon 15 Remote Signal 16 Temperature Display 17 Oscillation Icon 18 Fresh Air Icon lonizer 19 Oscillation Button2 20 Fan speed Button 21 Power Button Remove the rear cover by pulling it forward 3 Operating Instructions 1 When first plugging in the ACP 1300H a tone indicating that the power is connected will sound After pressing the On button the unit will start in Auto Mode and display the current room temperature Ol J 2 2 2 2 To select the mode press the Mode button This will then cycle the ACP 1300H through the Auto Heating Fan Cooling and Dehumidify options Auto Heating Fan Cooling Dehumidify 3 When adjusting the temperature keep in mind that the ACP 1300H is adjustable between 60 and 88
8. laced 1 Connect the power cord corre ctly 2 Reset the circuit at the breaker box 3 Change the socket or outlet 4 Take the unit to a qualified techn ician and have the fuse replaced fuse specification 3A 250V The unit stops working on its own Either the timer has been activated or the temperature in the room is lower than the set temperature Either turn the timer off or wait for the room temperature to rise There is no cool air coming out of the unit when itis in cooling mode 1 The room temperature is lower than the set temp erature 2 The evaporator is frosted over 1 Wait for the room temperature to rise to resume normal operation 2 Allow the evaporator to defrost and normal operation will resume There is no cool air coming out of the unit when it is in dehumidifying mode 1 The evaporator is frosted over 2 The unit is eliminating frost Allow the evaporator to defrost andnormal operation will resume Error code E2 is displayed on the control pane The water tank is full Empty the water tank and restart the unit Error code E4 is displayed on the control panel The coil pipe is damaged Replace the coil pipe Error code E1 is displayed on the control panel 1 The voltage is too high or too low 2 The unit is damaged 1 Restart the unit when the voltage is normal 2 Have the unit repaired by your NewAir dealer or at a professional
9. s must match the indicator in the remote control 2 Do not mix old and new batteries in the remote control 3 To prevent corrosion remove the batteries if the remote control will not be used for an extended period of time 10 3 Operating Instructions Drainage When the ACP 1300H is in operation the condensed water will be drained into the water tank If the water tank is full a buzzer will sound 20 times and the VED indicator will display an E2 error warning At that time the unit will cease operation and if you wish to restart the unit the water tank must be emptied by taking the following steps 1 Turn off the unit 2 Remove the rubber plug The condensed water will then flow out 3 After the water is emptied replace the rubber plug 4 Restart the unit Drainage Hole Rubber Plug Water Tank 11 3 Operating Instructions Air Exhaust Hose The hot air exhaust conducts the hot moist air produced by the unit away from the space you are cooling The window kit and exhaust hose can also be moved from room to room with the unit You can exhaust the ACP 1300H by following one of the following two methods 1 Exhaust the hot air through a window or sliding glass door a window kit extension may be necessary Open the window or sliding glass door install the window kit and connect the exhaust hose a z Sy o ie 2 lf an existing window or
10. t the air conditioner s cooling efficiency When removing the filter from the ACP 1300H following these steps 1 Gently lift up the air filter cover 2 Grasp the air filter and separate it from the cover Please Note When cleaning the air filter use only warm water or a mild detergent Once the filter has been cleaned allow it to completely dry in a cool place Also remember that the external case should only be cleaned with a soft moist cloth 2 Parts List Parts and Accessories ei a SI AUO N gt 17 mm lt gt 3 14 a 1 Control Panel 2 Air Outlet 3 Remote Sensor 4 Handle 5 Exterior Air Inlet 6 Caster 7 Filter 8 Interior Air Inlet 9 Power Cord 10 Air Exhaust Outlet 11 Exterior Air Inlet 12 Cover Board 13 Exhaust Joint 1 14 Exhaust Joint 2 15 Exhaust Joint 3 16 Exhaust Joint 4 17 Exhaust Hose 18 Water Tank 18 2 Parts List Display Panel Display Panel Icons 1 2 1 Fresh Air Icon lonizer 3 2 Timer Icon 3 Temperature Display AIR FRESH SET TIME e 888 88 env A or Error Code 4 Cooling Icon 5 Dehumidification Icon T 6 Auto Mode Icon 8 7 Heating Icon 9 8 Fan Speed Icon 9 Air Sweep Icon Control Panel Buttons 10 0n Off 11 Mode 12 Fan Speed 13 Timer 14 Oscillation Button1 15 Oscillation Button2 16 Temperature Adjustment
11. ull the power cord When not using the unit for an extended period of time disconnect the power cord and drain any water from the auxiliary water tank When cleaning the ACP 1300H do not spray liquid directly onto the unit Moreover do not use harsh chemicals or cleansers to clean the unit Instead apply water ora mild cleanser to a soft cloth and wipe the ACP 1300H clean The ACP 1300H is not intended to support heavy objects be used as a step stool or be shaken or bumped into Keep this in mind when deciding where to place the unit if you choose to use the continuous drain function on the ACP 1300H make sure the condensate can drain off into an appropriate receptacle To ensure adequate air circulation place the air conditioner at least four inches away from walls and furnishings Be aware of draperies or other items which may interfere with the intake vents and cause restricted airflow Place the ACP 1300H on a level flat surface Do not operate the unit on an angle of more than 4 inches 1 Safety Instructions Maintenance To avoid electrical shock be sure to disconnect the power cord before cleaning the unit Avoid using chemicals such as benzene alcohol gas or turpentine when cleaning the unit It is recommended that the air filter be replaced every two months more frequently if the filter is visibly soiled Built up dust and debris on the filter will decrease airflow and impac

Download Pdf Manuals

image

Related Search

Related Contents

TightSight® Clamp Meters  Home Decorators Collection 2238200980 Use and Care Manual  DLC-100J - Cuisinart  NAS Drive セットアップガイド  ASRock IMB-A180-H Owner's Manual  フード DH-23GR  Cables Direct AD-144  manuale di uso e manutenzione gb operator`s instruction book  2.4Gパワーポインター取扱説明書(保証書)  Hyundai HLTY-37F2 LCD TV  