Home

Monte Carlo Fan Company 5STR52 User's Manual

image

Contents

1. for the blade arms iit gt N Place blade arm over label on the fan body and tighten the 2 screws in the blade arm to the fan body screws only start screws Repeat for each long blade arm Place motor cover over 3 screws and twist cover into position Take 3 screws removed ear lier and replace tighten all 6 screws securely downrod y canopy yoke cover Thread wires and safety cable from fan through yoke cover canopy and downrod Install cotter pin into cross pin to secure For Canadian installation in both flush and downrod mode the safety cable must be installed into the house structure beams using the 3 lag screws provided Make sure that when the safety cable is fully extended the leadwires are longer than the cable and no stress is placed on the leadwires PEFORM FOR LIGHT KIT IF USED Plug in the 3 light bulbs by aligning the 2 prongs on bulb with holes in socket and then push in and twist the 50 watt bulbs which are GU10 Loosen the 2 yoke screws Tn both yoke set screws to further secure down rod Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the eguipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Use caution with the sloted fitter arms do
2. Install wall control unit to outlet box using machine screws provided Fan speed control Fan on off o k o 7 Light dimmer for lights ery buttons ce lt gt T Fan reverse button To control fan speed select from High Medium or low speed buttons To turn the fan off press the Fan on off button To dim lights press and hold button To turn off light press and quickly release button Press button marked REV to reverse the rotation direction of the fan blades Remove cover by snaping off from top or bottom Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V Attach front cover to wall control with screws provided Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning de
3. Owner s Mehri Ceiling Fan Installation Instructions o VE E A a y cr Pe a yg RED y a Total fan weight For 5STR52 Fan READ AND SAVE THESE INSTRUCTIONS MONTE CARLO Quality Ceiling fans p Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS 1 Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes an 70 1999 including fire rated construction 2 Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer 3 After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding con ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 4 Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being Switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 5 Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams 6 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 7 Make sure the installation
4. ck this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 4 If light does not work 1 Check wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing WARNING Before attempting to replace the fuse make sure the main power is turned off to the fan Replace only with 3 amp fuse The fuse is inside the top housing MONTE CARLO Customer Service Center 740 S W Loop 820 Suite 110 Fort Worth Texas 76115 1 800 519 4092
5. cting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel TOOLS REQUIRED Phillips Screwdriver Wire Cutters Pliers Step Ladder fi aes _ Ua s Install the Mounting Bracket to the Outlet box Before you begin installing the fan Switch power off Before installing this fan make sure the outlet Use only the screws provided with the out at Service panel and lock service disconnecting means box is properly installed to the house structure let box to prevent power from being switched on accidentally To reduce the risk of fire electric shock or per When the service disconnecting means cannot be sonal injury mount to outlet box or supporting locked securely fasten a prominent warning device system acceptable for fan support such as a tag to the service panel Mounting must support at least 35 Ibs Slotted fitter arms Remote Receiver Dip switches Set dip switches on the Remote Transmitter and Remote Receiver to the same settings This must be done so the units will communcate properly If you have other fans you If using the light kit find wires from light and Use caution with the sloted fitter arms do not can set to control from one transmitter by setting both fan body Plug wires together as follows force the fitter arms in assembling when using receivers the same as the transmitter If you have more Connect blue wire from fan to black wire from the light kit Screw in
6. not force the fitter arms Align the 3 sloted arms with the 3 screws in glass Align holes in downrod and holes in yoke and install cross pin Use caution when hanging fan not to hold by blades are put any pressure on blades or blade arms This could create problems of blade pitch deviation deforming blade arms or scratching of blades Carefully lift fan assembly by fan body onto mounting bracket Rotate fan so that the notch on the ball engages the ridge in the mounting bracket This will allow hands free wiring House Fan Black E HED ack White White Green FALE Green downrod y Green Bracket Make wire connections as per above diagram Connect the white wire from the fan to the White or Neutral wire from the power source Connect the black wire from the fan to the Black or hot wire from the power source Connect all Green Yellow wires from the fan Downrod and mounting bracket to the Ground wire from the house When alligned push screw in glass into the slotted arm from light kit Install the cover of light kit holder tightly over the screw in glass and the slotted arm from fit ter twist cover counter clockwise Attach cover of remote by placing over buttons and snaping into place with the screws on the bottom of the Mounting bracket Rotate the canopy Counter Clockwise to lock in place Tighten the screws to secure the Canopy See inset for Keyhole shape
7. site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade 8 _ To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs 9 _ Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades 10 Attach the mounting bracket using only the hardware supplied with the outlet box 11 To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control 12 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application 13 NEVER place a switch where it can be reached from a tub or shower 14 The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 15 Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being Switched on accidentally When the service disconne
8. the 2 allen screws then than one fan with remote You can set the dip switches to light Connect white wire from fan to white wire Pc Wm Uin AUU slots as shown different positiosns to have seperate control from light the switch housing cap or light kit then tighten all 3 allen screws securely Place medallion on side of blade not marked this side up Flip the blade over and attach short arm to set of holes that are closest to the corner of the blade The remaining set of holes is for the long arm Repeat for each blade When attaching the second blade and arm to fan it should go under the first blade as shown in photo Repeat for the other blades and arms D Tin Attach the long blade arms to motor after attach ing to blade Tighten screws to motor securely and repeat for each blade arm Caution go back and securely tighen screws in step 15 Loosen the 3 screws with slots and remove the other 3 screws Save the screws Use this label on the fan body for the first blade arm starting position Use caution with blade arms and blades Any pressure on blade arms or blades such as holding fan by blades or blade arms can create problems of blade pitch deviation or deforming blade arms Place medallion in blade for long blade arm Repeat for each blade T P 4 j y t Thread wires and safety cable through motor cover To remove the top motor cover twist the cover and remove this will allow acesss to the screw holes
9. vice such as a tag to the service panel 1 If fan does not start 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing 3 Check to make sure the dip switches from the transmitter and receiver are set on the same frequency CAUTION Make sure main power is turned off 2 If fan sounds noisy 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 3 If fan wobbles 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Che

Download Pdf Manuals

image

Related Search

Related Contents

El modo AFE avanzado es más sofisticado y puede  Manual de Instruções  Instruções de operação  0509 eng doc2.fm - Support  InLine Mini-SAS 36pin SFF-8087, 1m    Quick Start Unit Software Setup  Instrucciones de servicio - VEGACAL CL6*.D****P/F****  Manuel_utilisateur_1..  Juniper EX4200  

Copyright © All rights reserved.
Failed to retrieve file