1. This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state province to province Some states provinces do not allow the exclusion or limitation of incidental or consequential damages or limitation on how long an implied warranty lasts so the aforementioned exclusion and limitation may not apply to you LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual NOTES LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual 19 U S A Corporate Headquarters Graham Field Health Products 2935 Northeast Parkway Atlanta Georgia 30360 telephone 800 347 5678 770 447 1609 fax 800 726 0601 678 291 3232
2. is completely left the bed 10 Transfer to another object can be done at this position without the patient attending a full standing position 11 Release the brakes close the base and pull the lift away from the bed 12 Lower the patient to the object intended 13 To lift patient in a standing position continue to lift until the patient s knees are locked in a standing position 14 At the standing position patient s knees may move away from the knee pad 15 Close the base and pull the lift away from the bed 16 Lower the patient to the object intended 17 Reverse the above procedures when lowering the patient to the bed IA S LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual Lift and Transfer From Chair 1 Fit sling as described in Fitting Lumex Sit To Stand Sling 2 Push lift towards patient Open the base of the lift to go around the chair Apply the brakes on both rear casters 3 Position patient s feet on the foot platform and knees against the knee pad 4 Attached the sling straps to the hooks 5 Have the patient s hands holding the handles For patients who cannot hold the handles have them hold their arms around the chest 6 Press the UP button on the hand control 7 Before the patient s body is lifted from the chair stop and make sure the sling is secured and patient s knees are against the knee pad 8 The patient should be comfortable w
3. moen CC A Ir TCE E H T H Fee LT H T HH ES U H EE ES LT H EE HT H ER L 5 H ee Fe Ensure that the actuator connecting cable is tight 14 LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual TROUBLESHOOTING Z Warning If you experience a problem with your lift and are unable to service it yourself contact your Graham Field Health Products dealer Symptom Possible Cause Control box is not responding and relay is not clicking Actuator does not run but relay is clicking Actuator goes up or down but not both Cannot lift patient up and battery indicator shows no GREEN light Lift does not work and the battery indicator shows full charge Lift does not work and the battery indicator shows no light Stop and Run while lifting or lowering patient Battery Indicator shows no light when charger is connected to power supply Lift does not work Battery indicator shows full charge Notice click sound from control box when UP or DOWN button on hand control was pressed LF2020 LF2090 Sit To Stand Patient Lift Batteries discharged Battery charger defective Batteries defective Hand control defective Charge batteries Replace battery charger Replace batteries Replace hand control Actuator plug not properly seated Push actuator plug firmly into control box Actuator defective Replace actuator Control box defective Replace control box Hand control defective Replace hand control Control box defec
4. The lift moves freely with caster brakes off e Rear caster brakes operate properly e Base adjustment mechanism operates easily Lubrication Under normal use your Lumex patient lift was designed with minimum maintenance in mind however a six 6 month check and lubrication should ensure that your patient lift will remain in peak operating condition The casters MUST roll and swivel freely Lightweight waterproof grease LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual such as automobile lubricant should be applied to the ball bearings of the casters every six 6 months Apply grease more frequently if the casters are exposed to periods of excess moisture Lubricate all pivot points with lightweight oil Clean patient lift of all excess oil and grease Before use of the patient lift and every month thereafter place a drop of oil on the following areas e The point where mast and boom connect e Caster axles e The point where actuator and boom connect Cleaning Regular cleaning is recommended A soft cloth dampened with water and a mild NON ABRASIVE detergent household cleaner soapy water or hospital grade disinfectant is all that is needed to clean your patient lift Automobile wax or furniture polish will help maintain the finish over a long period of time DO NOT wash under water pressure or steam clean Checking for damage and wear It is extremely important to frequently check the areas of the patient l
5. light on Replace batteries Overloaded Batteries are charged E 3 long beeps but lift doesnot lift Exceeded maximum load capacity 12 LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual CARE AND MAINTENANCE Proper care and maintenance is essential to keeping your Lumex patient lift in safe operating condition In addition to inspecting the unit before each use periodic maintenance checks should be done as needed The lift should be thoroughly inspected by a person qualified to recognize any signs of wear and tear and looseness of bolts or parts Replace any worn parts immediately We further recommend that this unit be serviced at least once annually by an authorized dealer A Warning It is extremely important that the patient lift be inspected before each use Ensure that all hardware and accessories are secure and that the actuator is functioning properly Failure to do so could result in patient attendant injury or damage to your patient lift Torn cut frayed or broken slings could fail resulting in serious injury Use only slings in good condition Inspect before each use Destroy and discard old worn and unusable slings When you believe a component or part is not functioning properly immediately contact your authorized Graham Field Health Products dealer as a potentially hazardous condition could exist Before each use Before each use of the patient lift ensure that e All nuts and bolts are tight e
6. F2090 Sit To Stand Patient Lift A Warning Do not put anything e g cushion pad etc between the user and the sling This may cause user to slide out of the sling and cause injury A Warning Replace any worn or broken parts immediately Torn cut frayed or broken slings can fail resulting in personal injury Use only slings that are in good condition A Warning Service and repair of the LF2020 LF2090 Sit To Stand Patient Lift should be performed only by an authorized Graham Field Health Products dealer Graham Field is not responsible for any consequence resulting from any unauthorized service or repair A Warning Do not exceed the maximum weight allowed LF2020 400 pounds LF2090 600 pounds A Warning Unauthorized modification of your patient lift or the use of non Lumex replacement parts may change the structure of the lift and could create a hazardous condition which could result in serious injury and will void the warranty A Warning The electronics and actuator contain no serviceable components If service is required the unit must be returned to the factory for repair DO NOT attempt to open the electronics or actuator or obtain local service this will void the warranty and could result in damage to the unit Consult your Graham Field Health Products Dealer for further information A Warning Do not attempt to transfer a patient without prior approval of the person s healthcare provider A Warn
7. LUIMIEX SIT TO STAND PATIENT LIFT Models LF2020 amp LF2090 OWNER S MANUAL TARP Cee OGF Health Products Inc IMPORTANT READ THIS RNE BEFORE OPERATING YOUR PATIENT LIFT CONTENTS INTRODUCTION aserne BERS SCORERS Rese SENOS RIOR RO DE ESE REESE ROE eRe eee eS 4 SPECIAL NOTES estes es tea ds ed Dra es ot tak DR a tne Pan els Ed ts Da R does sees 4 SAFETY PRECAUTIONS voc os nos ong meee CS RE EE OC a Ones shee ome es 5 6 FEATURES seeding 8 ce Rd Kg ne emca a beer adi ee K RR R ER K ae K RAE ae betas twee K RR TR 7 HANDLING PROCEDURES or ED ERRA RRR VEUS EV DERES 7 ASSEMBLY INSTRUCTIONS ot sateni et Rec Z bas ed Rec A Dadoa Ket H Nad et Reg ia dod ee Ker bas 8 OPERATING INSTRUGCTIONS ste ED na cand ee ed pg a aang anti ad Ad pen orcs 9 12 CARE AND MAINTENANCE nos ese aco o way UE Ng On SRN enw Ne OE ta 13 MAINTENANCE SCHEDULE 5 a rede ea DE ER ds Reinga Sw Sree de 14 TROUBLESHOOTING caus ccecen peres cies eta seda peces Ges ee eee Rp Sa R AR KET ATO eee Se 15 SPECIFICATIONS i 43 3440 Rd R KR RR RRR R R KR R RAER K da R eR eee tahoe 16 LIMITED WARRANTY eR RR A RRR R Ta RR sores TRR me sense nen 17 18 LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual 3 INTRODUCTION Congratulations on your purchase of a Lumex patient lift The following pages will provide you with important safety and operating instructions on the use of patient lifts slings and accessories as well as maintenance and warranty information Re
8. Velcro waist belt A Warning The Lumex Sit to Stand sling is not suitable for patients who have involuntary movements or patients with limited postural control 1 Position the patient in a sitting position 4 Draw the waist belt around patient s waist and press together to fasten 2 Slide the sling down patient s back to lumbar position 5 Place shoulder straps inside of positioning loop 3 Draw the shoulder straps to the front of the patient close to the chest 6 Attach the shoulder straps to the hooks LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual 9 Lift and Transfer From Bed 1 10 Fit sling as described in Fitting Lumex Sit To Stand Sling Push lift towards patient Open the base of the lift Apply the brakes on both rear casters Position patient s feet on the foot platform and knees against the knee pad Attach the sling straps to the hooks Have the patient s hands holding the handles For patients who cannot hold the handles have them hold their arms around the chest Press the UP button on the hand control Before the patient s body is lifted from the bed stop and make sure the sling is secured and patient s knees are against the knee pad The patient should be comfortable with the pressure under the arms If not adjust the sling and try another loop option to release pressure Press the UP button until the patient s body
9. ad this manual carefully before operating your patient lift and refer to it as often as needed Consult your Graham Field Health Products dealer and or healthcare professional with any questions or concerns regarding safe and effective techniques for operating your patient lift DO NOT attempt any transfer without prior approval of the patient s healthcare provider With their assistance select the sling that best serves the needs abilities comfort and safety of the person being lifted It is important that you use correct slings adapted to the body shape and weight and ability of the patient and the specific type of transfer needed Upon receipt of the patient lift and prior to each use inspect it closely to ensure that nothing is damaged there are no loose or broken parts that all patient lift parts are in the proper place etc Immediately replace any worn or broken components Your patient lift should receive maintenance on a regular schedule and should be inspected daily for proper operation Contact your Graham Field Health Products dealer for service and repairs Before lifting anyone thoroughly read the instructions in this manual Observe a team of trained experts perform the lifting procedures The operator should practice the entire lifting procedure several times with proper supervision and a capable individual acting as patient It is extremely important to know how a patient will feel in the patient lift We sugg
10. batteries run down to the last one GREEN light red light This could shorten the life of the 4 Do not use the lift when no GREEN light is batteries or damage the batteries shown Charge the batteries immediately 9 Unplug the charger first before using the lift 5 Replace batteries when frequent charging THE LF2020 LF2090 SIT TO STAND PATIENT is needed Reorder DPL650BAT LIFT WILL NOT OPERATE WHILE CHARGING CHARGING THE BATTERIES IMPORTANT NOTES ON CHARGING 1 Ensure the power is switched ON the red 1 Push lift to charging location and charge the RESET button should be up batteries with the charger provided Avoid 2 Insert charging plug into charging port on the unplugging hand control and motor from control box control box Frequent plugging unplugging of 3 Plug charger to power supply the hand control and motor into from the 4 All lights of battery indicator should be control box could damage the control box ON while charging 2 Do not charge batteries over 12 hours 5 It takes approximately 2 3 hours to fully Know What The Battery Indicator Lights Are Telling You C TRT TT ON OFF CHARGE IMMEDIATELY DON T USE THE LIFT BAD BATTERIES OR BAD CONNECTION Warning Buzzers The control box has a buzzer that provides you with information on the status of the batteries and the lift To stop the buzzer push down the RESET button or press the Battery Indicator 3 beeps every Gn Bad Battery no
11. est that the operator try all the various lifting slings and equipment until the operator is confident with how the patient lift operates The lifting procedures should be explained to the patient before the actual lifting Remember that safety requires the constant attention of the lift occupant and the operator Use extreme care when operating a patient lift This guide covers the use of the LF2020 LF2090 Sit to Stand Patient Lift Keep in mind that the basic safety procedures included in this manual are to be used as a guide only Again consult your healthcare professionals for their recommendations and never hesitate to ask for their assistance Note Before attempting to assemble the patient lift refer to the section titled ASSEMBLY INSTRUCTIONS contained elsewhere in this manual Contact your Graham Field Health Products dealer if additional assistance is needed SPECIAL NOTES A Warning Do not operate this equipment without first reading and understanding this manual If you are unable to understand the warnings cautions and instructions contact your dealer or a healthcare professional before attempting to use this equipment Failure to do so may result in serious injury or damage to your patient lift LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual MAINTENANCE Maintenance MUST be performed by qualified personnel ONLY A Warning Warning notices as used in this manual apply to hazards or unsafe pract
12. ices which could result in personal injury Caution Caution notices as used in this manual apply to hazards or unsafe practices that could result in property damage Note Notes highlight procedures and contain information which assist the operator in understanding the information contained in this manual Note The information contained in this document is based on the latest product information available at the time of publication Graham Field reserves the right to make changes at any time without notice Note In this manual the person being lifted is referred to as the patient or occupant and the person operating the patient lift is called the operator or attendant SAVE THESE INSTRUCTIONS AND KEEP WITH PATIENT LIFT AT ALL TIMES SAFETY PRECAUTIONS IMPORTANT Before using patient lift please read and adhere to the following safety precautions and warnings Failure to do so could result in serious injury or damage to your patient lift Always consult your healthcare professional to determine safe methods most suitable for your individual abilities Protect yourself your attendant and patient lift by having it serviced Warnings A Warning Check all parts for shipping damage before using In case of damage DO NOT USE the equipment Contact the carrier or your authorized Graham Field Health Products dealer for further instructions A Warning Patient lift may tip over if used incorrectl
13. ift that are under a great deal of stress for damage and wear These areas include slings spreader bars spreader bar suspension and mounting hardware pump mounting hardware and all pivot points Inspect for signs of cracking fraying deformation and any loose components Replace any defective parts immediately and make certain that the patient lift is not used until repairs are made Contact your authorized Graham Field Health Products dealer for replacement parts Care of sling Lumex slings are easy to maintain They are washable at 150 F The slings can be dried by using a dryer on LOW heat or by hanging Note Slings should not be bleached 13 MAINTENANCE SCHEDULE Note Only qualified persons should service and repair your Lumex patient lift Regular maintenance of your patient lift is necessary to ensure continuing proper and safe operation Read and observe the following recommended maintenance schedule Inspect Inspect Inspect Inspect adjust Item initi j j every 6 months Base Casters and Foot Paddle Ensure that base is level all four wheels touch the floor Ensure that bolts and nuts are tight Ensure that casters swivel and roll freely Apply a light grease to caster ball bearings Check rubber parts of casters for deflection Check welding joints for rust and cracks Base Adjustments Ensure that base opens and closes smoothly Ensure that base locks securely in three positions Ensure that locking k
14. ing Graham Field Health Products specifically disclaims responsibility for any bodily injury or property damage which may occur during any use which does not comply with federal state or local laws or ordinances LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual FEATURES Base Mast Control Box Pendant Actuator Lifting Boom Kneepad Assembly Footrest Brake Oo won nu fk Ww DR mm HANDLING PROCEDURES SHIPPING AND TRANSPORTATION INSTRUCTIONS If the patient lift is to be reshipped by common carrier it should be packed in the same carton s in which it was received Unpacking 1 Check for any obvious damage to the carton or its contents If damage is evident notify the carrier or your authorized Graham Field Health Products Dealer 2 Remove all loose packing from the carton 3 Carefully remove all the components from the carton Note Unless the patient lift is to be used immediately retain boxes containers and packing material for use in storing until use of patient lift is required LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual Inspection 1 Examine the exterior of the patient lift for nicks dents scratches or other damage 2 Inspect all components Storage 1 Store the repackaged patient lift in a dry area 2 DO NOT place other objects on top of the repackaged patient lift ASSEMBLY INSTRUCTIONS 1 Open the box and take lift out 2 Un
15. ith the pressure under the arms If not adjust the sling and try another loop option to release pressure 9 Press the UP button until the patient s body is completely left the chair LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual 10 Transfer to another object can be done at this position without the patient attending a full standing position 11 Release the brakes close the base and pull the lift away from the chair 12 Lower the patient to the object intended 13 To lift patient in a standing position continue to lift until the patient s knees are locked in a standing position 14 At the standing position patient s knees may move away from the knee pad 15 Release the brakes close the base and pull the lift away from the chair 16 Lower the patient to the object intended 17 Reverse the above procedures when lowering the patient to the chair 11 CHECKING THE BATTERIES charge the batteries from one green light 6 It takes approximately 7 9 hours to fully charge the batteries from the red light 7 Do not leave the batteries on charging for an extended period of time This will shorten 1 Check batteries by pressing the Battery Testing Button blue circle with a battery sign on the control box 2 Batteries are fully charged when all lights on i the Battery Indicator are ON the life of the batteries 3 Charge batteries when Indicator shown only 8 Do not let the
16. nob is in place and operating properly Inspect all base hardware for wear Ensure that mast is fully engaged and locked into mast sleeve Inspect mast for bends or deflections Inspect all mast hardware for wear Inspect boom for bends or deflections Ensure that boom is centered between the base legs Inspect all boom hardware for wear Inspect sling hooks for wear or deflections Check connections between boom and mast for improper connection looseness or wear Inspect slings and straps for wear or damage Inspect metal plastic parts for wear or damage Lubricate all pivot points with light oil Lubricate top and bottom of actuator mounting Clean with mild non abrasive detergent lectronics and Actuator Ensure that batteries are charged Inspect for proper up down operation Ensure that mounting hardware is tight Inspect mounting hardware for wear Ensure that control box is firmly affixed to the mast y y EES T eee E HT E ES HE SE E T moree DE Ta Pe e e UE ES o EG EG a SR EE ESO EE EE ESTIL DS USEE ee Base Adjustments ED a H T ee ee ee E ea DE dE JE ED ee EE Em DD LE US DE JE EU ET SE HE EI ri E Ce E EE EE aa ae NU H EE S EET DE ICS EE H EE EC EE ES Ri DE DEURES ES EE EES IE Dr loa se EE H e a o ES Li ii T SEER SE SE T SE e EES IES ES o EE ES ES H EEES I ES Slings TTT IE a EEES EES Ii i D EN A EE ES EI EI TS ES EE ES Eco comer doma O E ET Ra PETITES o ESE EET EE EE Electronics and Actuator S ST
17. ply to serial numbered products if the serial number has been removed or defaced Products subjected to negligence abuse misuse improper operation improper maintenance improper cleaning improper storage or damages beyond GF Health Products Inc s control are not covered by this warranty and that evaluation will be solely determined by GF Health Products Inc This warranty shall not apply to problems arising from normal wear and tear or failure to follow instructions This warranty shall also not apply to products modified without GF Health Products Inc s express written consent nor will it apply if parts not manufactured by GF Health Products Inc or if parts not complying with original equipment specifications are added to a GF Health Products Inc product or if the product or part is serviced by an entity not authorized by GF Health Products Inc 17 THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESSED WARRANTIES AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESSED WARRANTY PROVIDED HEREIN AND THE REMEDY FOR VIOLATIONS OF ANY IMPLIED WARRANTY SHALL BE LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT OR PART PURSUANT TO THE TERMS CONTAINED HEREIN GF HEALTH PRODUCTS INC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER
18. rrants the LF2020 LF2090 Sit To Stand Patient Lift against defects in materials and workmanship as listed below PRODUCT WARRANTY PERIOD Frame Parts 1 Year Electric Motor 1 Year The warranty period for the consumer commences on the first date a product is delivered to consumer by seller dealer If the product is rented or leased the warranty period commences on the invoice date from GF Health Products Inc A copy of the invoice showing date of purchase must be provided Without a proof of purchase date warranty coverage shall commence upon GF Health Products Inc s invoice date to the dealer purchaser If within the warranty period the product or component part is proven to GF Health Products Inc s satisfaction to be defective GF Health Products Inc shall provide at its option one of the following 1 repair or replacement of any defective or non conforming part or product or 2 a refund of the original purchase price less depreciation GF HEALTH PRODUCTS INC S SOLE OBLIGATION AND YOUR EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual LIMITED TO SUCH REPAIR REPLACEMENT AND OR REFUND This warranty does not include any labor charges incurred in replacement part s installation Freight charges to the manufacturer are at the expense of the consumer or purchaser and will not be reimbursed LIMITATIONS AND EXCLUSIONS The foregoing warranty shall not ap
19. screw nuts and bolts at top and bottom of the mast 3 With one hand on the mast and another on the boom stand the mast up 4 Put bolts through the bottom two holes at the base of the mast and hand tighten them 5 Attach boom to mast and hand tighten bolt and nut 6 Attach the L shaped arms to back of the kneepad For desired height of the kneepad use proper holes on the L shaped arms 7 Attach kneepad assembly to the mast 8 Attach actuator and pendant to the control box 9 Tighten all nuts Z Warning Before using Sit to Stand Patient Lift ensure that lift is assembled as described that all attaching hardware is securely tightened and that all lift components are secure 8 LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual OPERATING INSTRUCTIONS Preparation Before Lifting 1 Turn on the power by twisting the REDRESET 3 After the battery indicator lights go out push BUTTON clockwise the UP button and the DOWN button on the hand control and ensure that the lift is 2 Press the UP or DOWN button on the hand operating correctly control once Check if the battery indicator lights are on To proceed with lifting make 4 Position of the base of lift around or under sure there is at least one green light Batteries the object are fully charged when three 3 green lights are shown 5 Widen the base Fitting Lumex Sit to Stand Sling Shoulder strap loop Shoulder strap Positioning loop
20. tive Replace control box Batteries discharged Charge the batteries Check the connection between the actuator and the control box Check connection between Pendant amp control box Make sure the emergency stop button is released Check the connection of the batteries in control box Check socket for pendant plug in Check pendant cable Check the emergency stop button is released Check charger plug for damage Check charger cable for damage Actuator problem Owner s Manual 15 SPECIFICATIONS Note All dimensions given in inches unless otherwise specified LF2020 LF2090 SIT TO STAND PATIENT LIFT Base width Open 43 Closed 26 Base height Clearance 6 Overall base length 50 Lifting height range Note As measured from sling hooks Minimum 27 Maximum 71 Range 35 Mast height 50 11 Weight capacity LF2020 400 Ibs LF2090 600 Ibs Rear locking caster size 4 diameter Front caster size 4 diameter Lifting mechanism 24 DC actuator Battery charger AC 110V 220V to DC 24V 1 amp LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual LIMITED WARRANTY NOTE The warranty below has been drafted to comply with the Federal Law applicable to products manufactured after July 4 1975 This warranty is extended only to the original purchaser consumer or dealer non consumer who does not buy for resale and to no other purchaser or transferee GF Health Products Inc wa
21. y Read and adhere to the operating instructions prior to lifting anyone LF2020 LF2090 Sit To Stand Patient Lift Owner s Manual regularly If you experience any malfunction contact your Graham Field Health Products dealer immediately as a hazardous condition could result causing personal injury or damage to your patient lift Periodic inspection adjustment and replacement of worn parts are necessary to provide years of excellent service A Warning The Lumex LF2020 LF2090 Sit To Stand Patient Lift is designed for use by individuals who can support the majority of their own weight Special care must be taken with patients who cannot provide assistance while being lifted i e such as patients who are comatose spastic agitated or otherwise severely handicapped A Warning The LF2020 LF2090 Sit To Stand Patient Lift should be used solely for transferring a patient from one object beds bathtubs toilets etc to another The lift should not be used for transporting or moving any patient from one location to another location A Warning Always keep the patient being lifted centered over the base and facing the caregiver operating the lifter A Warning Do not roll casters over any object while the user is in the sling A Warning To ensure stability while transferring a patient the patient lift legs should be locked in the maximum open position A Warning Use only Lumex slings specially designed for the LF2020 L