Home

Linear ACCESS AE-100 User's Manual

image

Contents

1. two short beeps sound Any entry other than 5 will cancel the command To allow for multi unit network communications when executing this command remotely over the telephone the system will disconnect your call after Step 3 then copy the data from the master unit to the sub units 17 FUNCTION CODE 31 ADD A STAND ALONE ACCESS CODE A Stand alone Access Code is a number entered at the AE 100 keypad to request access Up to 125 4 digit Stand alone Access Codes can be set NOTE Each Stand alone Access Code programmed reduces the possible number of Directory Entries by one 33 DELETE A STAND ALONE ACCESS CODE Deletes a single existing Stand alone Access Code 34 COPY ALL MASTER MEMORY TO SUB UNITS To synchronize programming in multi unit installations all system data can copied from the master unit to selected sub units This data includes the Directory Entries Stand alone Access Codes and all system option settings except the sub unit number NOTE This utility command can only be performed from the master unit ZA CAUTION This utility command will overwrite ALL data in the sub unit s selected 38 SYSTEM DISPLAY LANGUAGE The factory default language is English Three other languages can be selected as the language for the user and programming displays NOTE The system supports one display language at a time 18 p gt ALTERNATE PROGRAMMING METHOD lt
2. 2 E 2 Press 9 2 H again for verification Delete All Stand alone Entry Codes This utility command will permanently erase all Stand alone Entry Codes Z CAUTION This utility command will erase ALL the Stand alone Entry Codes in the unit NOTE This step cannot be performed remotely through the telephone Press 9 3 E 2 Press 9 3 E again for verification TIMED ACCESS RELAY LATCH 80 HOURS HOURS RELAY LATCH TIME IN HOURS 01 98 PPN 80 LATCH ACCESS RELAY 81 RELEASE ACCESS RELAY 83 DELETE ALL DIRECTORY ENTRIES Q2 92 DELETE ALL STAND ALONE ENTRY CODES 937937 13 gt ALTERNATE PROGRAMMING METHOD lt j Alternate Programming Section To make it easy for installers familiar with Linear s and other manufacturer s access control systems two methods of programming are available Function Codes that match other equipment help the installer to make quick programming changes with keystrokes they have used before Alternate Programming Method Selection The Programming Position Numbers or Function Codes change depending on the programming method used Refer to the table on Page 13 for the numbers used for each programming method The keys used to enter programming from the unit s keypad select which programming method is used for the current programming session Entering programming by pressing 0 amp E keys together will select the Alternate Programming Method o
3. Enter to cancel this command Enter Function Code 06 then press DIF DIGITS The display shows the current value Enter 2 or 3 then press OR Enter to cancel this command Enter Function Code 10 then press BLAWK DISPLAY Enter the new welcome message A total of 32 characters are allowed The display will advance to the lower line after the 16th character is entered on the upper line Enter after each character enter after the last character Enter Function Code 30 then press UMITS Enter the number s 2 3 and or 4 of all the sub units to copy the data to then press ARE YOU SURE 7 Enter 5 for verification then press OR Enter to cancel this command The installer must setup the system as a multi unit installation before this command will operate TELEPHONE PROGRAMMING Step 1 Enter Function Code 05 and press one short beep sounds Step 2 Enter the number of hours from 01 98 to energize the access relay then press OR Enter the 99 to energize the access relay indefinitely then press OR Enter the 00 to de energize the access relay then press Two long beeps and two short beeps will sound NOT AVAILABLE NOT AVAILABLE Enter Function Code 30 and press one short beep sounds Enter the number s 2 3 and or 4 of all the sub units to copy the data to then press one short beep sounds Enter 5 for verification then press
4. Enter Function Code 01 and press one short beep sounds Enter the new Directory Code 2 or 3 digits and press one short beep sounds If you hear two long beeps the Directory Number already exists return to Step 1 Enter the Name up to 16 characters press after each character then again after the last character one short beep sounds Enter Telephone Number up to 14 digits press after each number then again after the last number and press one short beep sounds Enter the 4 digit Access Code then press two short beeps sound 15 FUNCTION CODE 02 MODIFY AN EXISTING TENANT DIRECTORY ENTRY Choose a tenant s Directory Code to modify you must know the tenant s Directory Code to modify 03 DELETE AN EXISTING TENANT DIRECTORY ENTRY Deletes a single existing Directory Entry This command frees up memory occupied by an unused Directory Entry 04 CLEAR ALL TENANT DIRECTORY ENTRIES Deletes all existing Directory Entries This command will erase all Directory Codes Names Telephone Numbers and directory linked Access Codes CAUTION This utility command will erase ALL the Directory Entries in the unit 16 p gt ALTERNATE PROGRAMMING METHOD lt q LOCAL PROGRAMMING Enter Function Code 02 then press MODIFY DIR Enter the new 2 or 3 digit Directory Code ENTER THE HAME Then the tenant s current Name is displayed CURRENT MAME To keep t
5. Enter Function Code 34 and press one short beep sounds Enter the number s 2 3 and or 4 of all the sub units to copy the data to then press one short beep sounds Enter 5 for verification then press two short beeps sound Any entry other than 5 will cancel the command To allow for multi unit network communications when executing this command remotely over the telephone the system will disconnect your call after Step 3 then copy the data from the master unit to the sub units NOT AVAILABLE FUNCTION CODE 70 MAXIMUM VISITOR TALK TIME If for some reason the resident does not press the telephone keys to grant or deny access or does not hang up the system will automatically disconnect the visitor after 60 seconds At ten and five seconds before the disconnect a tone will sound on the telephone to remind the resident of the pending disconnect The resident can extend the talk time by pressing the key on their telephone The disconnect time can be adjusted from 10 180 seconds 71 ACCESS RELAY ACTIVATION TIME The factory setting will cause the access relay to activate for 4 seconds The activation time can be set from 4 99 seconds to accommodate different types of access control devices 72 KEYPAD LOCKOUT COUNT The system counts the number of invalid Access Codes entered at the keypad If the invalid entries exceeds the lockout count number the keypad is locked out for 9
6. FUNCTION CODE 05 MANUAL ACCESS RELAY CONTROL This command can be used to latch the access relay indefinitely or for a period of time and to unlatch the access relay 06 DIRECTORY CODE LENGTH Selects 2 or 3 digits for the Directory Code length factory default is 3 digits NOTE In multi unit installations if sub units are being updated with access data that has Directory Codes with more digits than the sub unit is set for the sub unit s Directory Code length number will be automatically adjusted to fit 10 WELCOME DISPLAY TEXT The AE 100 display will show a visitor a welcome message alternating with instructions on how to find and call a resident The welcome message can be customized to suit the installation 30 COPY ACCESS DATA ONLY FROM MASTER TO SUB UNITS To synchronize programming in multi unit installations the Directory Entries and Stand alone Entry Codes can copied from the master unit to selected sub units Z CAUTION This utility command will overwrite ALL the access data in the sub unit s selected p gt ALTERNATE PROGRAMMING METHOD lt q LOCAL PROGRAMMING Step 1 Enter Function Code 05 then press FEH 66 HOURS Step 2 Enter the number of hours from 01 98 to energize the access relay then press OR Enter the 99 to energize the access relay indefinitely then press OR Enter the 00 to de energize the access relay then press OR
7. closed 4 Enter the unit number 1 4 of the unit to log onto then press 4 In a single unit installation use the default unit number 1 NOTE Log on to the Master Unit 1 in a multi unit installation to program the master s memory The master s memory can then be copied to the other units 5 Enter the Master Password for the unit the factory setting is 123456 6 To program using the Standard Programming Method press E To program using the Alternate Programming Method press If the password is correct the system will sound two short beeps 7 Programming commands can now be entered from the telephone s keypad To program the system refer to the following pages of this manual e The Standard Programming Method steps are shown on Pages 7 13 e The Alternate Programming Method steps are shown on Pages 15 21 Telephone Audio Prompts When programming over the telephone each programming step consists of entering programming data using the telephone s keypad The system will sound beeps over the telephone to indicate correct or incorrect entries The audio prompts that give feedback during programming are different for each programming method Those differences are shown in the table to the right Re entering a Command After a Mistake If an incorrect entry or an incorrect key is pressed during programming press and start the programming step over again Exiting Programming Mode After programming be sure to exit P
8. 1 Enter Function Code 95 and TENANT COLL BK n press one short beep sounds Step 2 Enter 0 to disable tenant call back Step 2 The display will show the current setting Enter 1 to enable tenant call back allows the AE 100 to answer Enter 0 to disable tenant call back default Step 3 Press two short beeps sound the telephone and switch to Enter 1 to enable tenant call back TENANT CALL BACK The tenant call back feature speakerphone mode if the telephone call is within 60 Step 3 Press seconds of the last use of the NOTE This feature can only be used in AF100 TiS Bature gives single unit installations residents the capability to call a visitor back in case of a recently missed call The factory setting has this feature disabled Alternately this feature can be enabled NOTE The Automatic Telephone Answer feature Function Code 74 must also be enabled for this feature to function 21 AE 100 Operation Requesting Access with a Visitor Call e f the visitor already knows the resident s Directory Code number they can press H first then enter the Directory Code number to call the resident e f the visitor doesn t know the residents Directory Code number they can scroll through the alphabetical directory entries by pressing A or Y gt Pressing A scrolls from A Z gt Pressing W scrolls from Z A Holding down the A or W keys will scroll the display faster e When the visitor finds
9. 5 SUB UNITS EACH SUB UNIT NUMBER 2 4 TO COPY ALL DATA TO IN A MULTI UNIT INSTALLATION NOTE TO ALLOW FOR MULTI UNIT NETWORK COMMUNICATIONS WHEN EXECUTING THIS COMMAND REMOTELY OVER THE TELEPHONE THE SYSTEM WILL DISCONNECT YOUR CALL AFTER STEP 3 THEN COPY THE DATA FROM THE MASTER UNIT TO THE SUB UNITS gt srauoano procaanmnne memon System Utility Commands Continued Timed Access Relay Latch For servicing or testing while in Programming Mode the access relay can be latched manually from the keypad for a period of hours 1 Press 8 0 E 2 Enter the amount of time in hours 01 98 for the access relay to latch 3 Press Latch Access Relay For servicing or testing while in Programming Mode the access relay can be latched manually from the keypad for an indefinite period of time NOTE This command will reset and override and timed access relay latch set by PPN 80 1 Press 8 1 4 Release Access Relay For servicing or testing while in Programming Mode this command will release the access relay if it has been manually latched timed or indefinite Press 8 3 E Delete All Directory Entries This utility command will permanently erase all Directory Codes Names Telephone Numbers and resident s Entry Codes ZN CAUTION This utility command will erase ALL the Directory Entries in the unit NOTE This step cannot be performed remotely through the telephone 1 Press 9
10. 77 then press EWA 1 DISA i Enter 0 to disable resident control of the access relay Enter 1 to enable resident control of the access relay default Press TELEPHONE PROGRAMMING NOT AVAILABLE Enter Function Code 75 and press one short beep sounds Enter 0 to turn the keystroke chirps OFF Enter 1 to turn the keystroke chirps ON Press two short beeps sound Enter Function Code 76 and press one short beep sounds Enter 0 to turn the relay tone OFF Enter 1 to turn the relay tone ON Press two short beeps sound NOT AVAILABLE p gt ALTERNATE PROGRAMMING METHOD lt q FUNCTION CODE LOCAL PROGRAMMING TELEPHONE PROGRAMMING 91 To exit programming mode enter Step 1 To exit programming mode Function Code 91 then press enter Function Code 91 The AE 100 will automatically exit Programming Step 2 Press three short beeps sound Mode after five minutes of programming inactivity EXIT PROGRAMMING MODE Entering this command number will cause the unit to exit programming mode and return to normal operation 93 Enter Function Code 93 then press STAND ALONE ACCESS CODES Enter the Function Code 93 again This utility command wil for verification then press NOT AVAILABLE permanently erase all Stand alone Access Codes Z CAUTION This utility command will erase ALL the Stand alone Access Codes in the unit 9 5 Step 1 Enter Function Code 95 then press Step
11. CODE PPN 31 31 CODE CODE CODE NEW STAND ALONE ENTRY CODE CODE NEW STAND ALONE ENTRY CODE AGAIN FOR VERIFICATION DELETING A STAND ALONE ENTRY CODE 33 CODE CODE PPN 33 CODE THE STAND ALONE ENTRY CODE TO DELETE CODE THE STAND ALONE ENTRY CODE AGAIN FOR VERIFICATION p sci raona no System Options For most installations the factory settings for the system will be appropriate To customize the system enter programming mode via telephone or keypad Use the programming worksheet supplied to log any system option changes prior to entering it into the system For each of the following steps enter the Master Password and enter Programming Mode if the unit is not already in that mode Exit Programming Mode when all programming is complete System Display Language The factory default language is English Three other languages can be selected as the language for the user and programming displays NOTE This step cannot be performed remotely through the telephone NOTE The system supports one display language at a time 1 Press 3 8 E 2 Choose a language e Enter 1 for English e Enter 2 for Spanish e Enter 3 for French e Enter 4 for Portuguese 3 Press Keypad Lockout Count The system counts the number of invalid Entry Codes entered at the keypad If the invalid entries exceeds the lockout count number the keypad is locked out for 90 seconds The factory setting for the lockout count is thre
12. TELEPHONE ENTRY AUTOMATIC TELEPHONE ANSWER 61 ANSWER ANSWER 0 FOR AUTO ANSWER OFF ANSWER 1 FOR AUTO ANSWER ON FACTORY SETTING AUTO ANSWER ON SPEAKER CHIRP ON KEYSTROKE 624 CHIRP CHIRP 0 FOR KEYSTROKE CHIRP OFF CHIRP 1 FOR KEYSTROKE CHIRP ON FACTORY SETTING KEYSTROKE CHIRP ON SPEAKER TONE ON ACCESS RELAY ACTIVATION 63 TONE PPN 63 TONE 0 FOR ACCESS RELAY TONE OFF TONE 1 FOR ACCESS RELAY TONE ON FACTORY SETTING RELAY TONE ON Ek System Options Continued Maximum Visitor Talk Time Visitors will converse with residents over the telephone until the resident grants or denies access If the resident responds to the visitor s request by pressing their telephone key the system will hang up and release the telephone line If for some reason the resident does not press the telephone key or does not hang up the system will automatically disconnect the visitor after 60 seconds At ten and five seconds before the disconnect a tone will sound on the telephone to remind the resident of the pending disconnect The resident can extend the talk time by pressing the key on their telephone The disconnect time can be adjusted from 10 180 seconds 1 Press 6 4 4 2 Enter the disconnect time in seconds 010 180 3 Press E Resident Control of Access Relay The factory setting allows the resident to activate the access relay by pressing the 9 key on their telephone when a call from the AE 100
13. a resident displayed by pressing the key Use the programming worksheet supplied to organize the resident data prior to entering it into the system For each of the following steps enter the Master Password and enter Programming Mode if the unit is not already in that mode Exit Programming Mode when all programming is complete Changing the Directory Code Length The factory setting for the Directory Code length is 3 digits It can be set to 2 or 3 digits 1 Press 0 2 E 2 Enter the Directory Code length 2 or 3 3 Press Adding a Directory Entry for a Resident 1 Press 2 1 J 2 Enter the Directory Code that will be displayed for the resident 3 Press E NOTE To add the name using all capital letters press 4 before entering the name 4 Enter the Name of the resident to be displayed up to 16 characters Press H 6 Enter the resident s Telephone Number up to 14 digits Press and hold down the 1 2 3 or 4 key to enter 1 4 two second pauses Hold down the key for about two seconds Note Each pause entered counts as one of the 14 digits allowed in the telephone number 7 Press H 8 Enter a unique four digit Entry Code for this resident 9 Press E 10 Enter the four digit Entry Code again for verification 11 Press 4 Modifying an Existing Directory Entry Once a Directory Entry has been set it can be modified to change a resident s Name Telephone Number or Entry Cod
14. apartments or gated communities with up to 125 residents The system can be used in a lobby or outside Surface recessed and pedestal mounting options are supported The system utilizes hands free full duplex telephone communications between visitors and residents for granting access Housed in a locked rugged stainless steel faced enclosure the AE 100 features a lighted 12 key telephone style keypad and four operation buttons all with bright easy to see graphics The backlit two line directory LCD display scrolls a programmable welcome message and shows the directory Names and Directory Codes The system contains a built in microphone tamper resistant speaker and a TTY connector for the hearing impaired Multi lingual display programming prompts and voice help is available with a choice of English Spanish French Canadian or Portuguese language selection for the system The system can be programmed locally using the keypad or remotely with a touch tone telephone Instruction manuals and other support documents in Spanish French Canadian and Portuguese are available on the Linear Web site s AE 100 product page at www linearcorp com Optional features that the AE 100 supports are provisions for postal lock and color CCTV camera installation Operation In a typical installation the unit s memory is programmed with each resident s Directory Code Name Telephone Number and Entry Code Arriving visitors use the A or W keys to view t
15. is received This feature can be disabled Disabling this feature will only allow access by using resident Entry Codes and Stand alone Entry Codes at the unit s keypad 1 Press 7 7 E 2 Select the option for resident access relay control e Enter 0 to turn OFF resident access relay control e Enter 1 to turn ON resident access relay control 3 Press E Resident Call back The resident call back feature allows the AE 100 to answer the telephone and switch to speakerphone mode if the telephone call is within 60 seconds of the last use of the AE 100 This feature gives residents the capability to call a visitor back in case of a recently missed call This feature can only be used in single unit installations The factory setting disables the resident call back feature Alternately this feature can be enabled NOTE The Automatic Telephone Answer feature PPN 61 must also be enabled for the resident call back feature to function 1 Press 9 5 6E 2 Select the option for resident call back e Enter 0 to turn OFF the resident call back feature e Enter 1 to turn ON the resident call back feature 3 Press E MAXIMUM VISITOR TALK TIME 644 TIME TIME TIME UNTIL AUTO DISCONNECT 010 180 SECONDS FACTORY SETTING 60 SECONDS RESIDENT CONTROL OF ACCESS RELAY PPN 77 77 CONTROL CONTROL 0 TO DISABLE RESIDENT CONTROL CONTROL 1 TO ENABLE RESIDENT CONTROL FACTORY SETTING RESIDENT CONTROL ENABLED RESIDENT CALL
16. 0 seconds The factory setting for the lockout count is three The lockout value can be from one to nine Step 1 Step 2 Step 3 gt ALTERNATE PROGRAMMING METHOD Ei LOCAL PROGRAMMING Enter Function Code 70 then press TALE TIME G66 The display will show the current talk time setting Enter the new talk time 010 180 seconds Press Enter Function Code 71 then press OFEH TIME 4 The display will show the current access relay activation time setting Enter the new access relay activation time 04 99 seconds Press Enter Function Code 72 then press LOCK OUT COUNT 3 The display will show the current lockout count Enter the new lockout count 1 9 tries Press Step 1 Step 2 Step 3 TELEPHONE PROGRAMMING Enter Function Code 70 and press one short beep sounds Enter the new talk time 010 180 seconds and press two short beeps sound Press two short beeps sound Enter Function Code 71 and press one short beep sounds Enter the new access relay activation time 04 99 seconds Press two short beeps sound Enter Function Code 72 and press one short beep sounds Enter the new lockout count 1 9 tries Press two short beeps sound 19 FUNCTION CODE 74 AUTOMATIC TELEPHONE ANSWER The factory setting will allow the system to detect a ring signal on the telephone line and answer the call NOTE The automatic answer feature can be t
17. BACK 95 CALL BACK CALL BACK 0 TO DISABLE RESIDENT CALL BACK CALL BACK 1 TO ENABLE RESIDENT CALL BACK FACTORY SETTING RESIDENT CALL BACK DISABLED PPN 95 11 p soi raona no System Utility Commands Several utility commands are available for the system Utility commands can be used to copy data to other units in a multi unit installation clear memory and control the relays For each of the following steps enter the Master Password and enter Programming Mode if the unit is not already in that mode Exit Programming Mode when all programming is complete Copy Access Data Only from Master to Sub units To synchronize programming in multi unit installations the Directory Entries and Stand alone Entry Codes can be copied from the master unit to selected sub units NOTE The installer must setup the system as a multi unit installation before this command will operate NOTE This utility command can only be performed from the master unit ZN CAUTION This utility command will overwrite ALL the access data in the selected sub units 1 Press 3 0 2 Enter the unit number s of all of the sub units to receive the access data Examples e To copy to unit two only enter 2 47 e To copy to unit three only enter 3 4 e To copy to units two amp three enter 2 3 H e To copy to units two three and four enter Haer 3 To execute the command enter 5 4 or enter Gk to exit any other entry will abo
18. HE RESIDENT S NAME UP TO 16 CHARACTERS PHONE THE RESIDENT S TELEPHONE NUMBER UP TO 14 DIGITS CODE THE RESIDENT S ENTRY CODE 4 DIGITS DELETING AN EXISTING DIRECTORY ENTRY 23 DIR DIR DIR DIRECTORY CODE FOR THE RESIDENT DIR DIRECTORY CODE ENTERED AGAIN FOR VERIFICATION p src en Stand alone Entry Code Programming A Stand alone Entry Code is a number entered at the AE 100 keypad to request access Up to 125 4 digit Stand alone Entry Codes can be set NOTE Each Stand alone Entry Code programmed reduces the possible number of Directory Entries by one Use the programming worksheet supplied to organize the Stand alone Entry Code data prior to entering it into the system For each of the following steps enter the Master Password and enter Programming Mode if the unit is not already in that mode Exit Programming Mode when all programming is complete Adding a Stand alone Entry Code Stand alone Entry Codes are entered individually 1 Press 3 4 4 2 Enter the new Stand alone Entry Code 3 Press 4 Enter the new Stand alone Entry Code again for verification 5 Press H Deleting a Stand alone Entry Code Stand alone Entry Codes can be deleted individually to delete all Stand alone Entry Codes see programming Step 93 1 Press 3 3 Enter the Stand alone Entry Code to delete 2 3 Press E 4 Enter the Stand alone Entry Code to delete again 5 Press H ADDING A STAND ALONE ENTRY
19. SWERED THE VISITOR CONVERSES WITH THE RESIDENT 2 THE RESIDENT GRANTS OR DENIES ACCESS TO GRANT ACCESS PRESS 9 OR TO DENY ACCESS PRESS ENTRY CODE ACCESS PRESS STAR FIRST TO CLEAR THE KEYPAD 4 OPTIONAL THEN KEY IN A DIRECTORY ENTRY CODE OR STAND ALONE ENTRY CODE UP TO 8 SECONDS ARE ALLOWED BETWEEN EACH KEYSTROKE UP TO 40 SECONDS ARE ALLOWED TO KEY IN THE ENTIRE ENTRY CODE ALL FOUR DIGITS MUST BE ENTERED INCLUDING LEADING ZEROS IF A MISTAKE IS MADE PRESS STAR KEY TO START OVER THE KEYPAD WILL LOCKOUT AFTER TOO MANY INCORRECT ENTRIES WHEN A CORRECT CODE IS ENTERED THE ACCESS RELAY WILL ACTIVATE RESIDENT CALL BACK 1 CALL THE SYSTEM WITHIN 60 SECONDS OF A VISITOR S MISSED CALL 2 THE SYSTEM ANSWERS AND SOUNDS ONE SHORT BEEP 3 CONVERSE WITH THE VISITOR 4 TO GRANT ACCESS KEY IN AN ENTRY CODE OR TO DENY ACCESS PRESS Troubleshooting System will not answer an incoming call 1 Automatic telephone answer disabled 2 AE 100 telephone line trouble Keypad will not activate a relay 1 Entry code is not assigned 2 Keypad may be in lockout from too many incorrect attempts Wait 90 seconds for lockout to clear and try again Resident s Telephone does not ring when a visitor Calls 1 Resident s Telephone Number programmed incorrectly 2 Check AE 100 telephone line 3 Call resident from another line or cell phone to determine if the resident s telephone is working L
20. Tr EGEHSS AE 100 Commercial Telephone Entry System Facility Manager s Guide Linear 760 438 7000 USA amp Canada 800 421 1587 amp 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com Contents INGFOCUCTION oes cece cccecsccscessscssesscessesesesceseuseseseusessuseveususeseuseseuseuenseses 2 Operatie aana n eR ERNS 2 Database Overview w ccccccccccscscscscscsssssssssescssssevessssseecetesesessnnenens 2 System Feat S irisan a daa as Programming from the Keypad Multi unit Msaani Programming Over the Telephone Programming Reference amp Factory Defaults 6 Resident Data Programming csesssseseseeseeseenesisseenssteseenseteneenseteees 7 Stand alone Entry Code Programming System OPtONS 4 scsecsdetersneeceascsneaessetucrsssudhatheacduestieserunssteverseesetentetagest System Options Continued System Options Continued System Utility Commands cseesesseseseeseeesteseesestesessesteseeneetestenseeeeees System Utility Commands Continued cscsccssseseeeeeeteeeeeeeees 13 Alternate Programming Se ction c cccscsseseeesesesssseeeeeenee 14 Alternate Programming Reference cccsesseseseeseseseesesssteneeeetens 15 AE 100 Operationen anaa Troubleshooting eeee Linear Limited Warranty POG INOUCG Saden ee tare esearch eerie Introduction The Model AE 100 Commercial Telephone Entry System is designed for use as an access control device for small
21. Z backspace or erase 0 entire line finish entry space minus sign dot 1ST PRESS IS 1ST LETTER 2ND PRESS IS 2ND LETTER 3RD PRESS IS 3RD LETTER e 4TH PRESS IS THE KEY NUMBER 5TH PRESS IS 1ST LETTER AGAIN e WAIT 3 SECONDS FOR THE NEXT CHARACTER A BEEP WILL SOUND AFTER THE 3 SECOND DELAY TIME OR PRESS ANOTHER KEY e THE FIRST LETTER OF EACH WORD WILL BE UPPER CASE TO MAKE AN ENTIRE WORD UPPER CASE TEXT ENTER FIRST FINISH ENTRY BY ENTERING PRESS STAR KEY TO BACKSPACE PRESS STAR AGAIN TO ERASE LINE Programming Over the Telephone Most system commands can be programmed using a TouchTone telephone The telephone s keypad will act similar to the AE 100 s keypad Both programming methods can be used over the telephone Connecting with a Telephone 1 Place a call to the telephone number of the line that the AE 100 is connected to 2 The AE 100 will answer on the third ring 3 The system sounds beeps indicating the current system status including any other units in a multi unit installation e One short beep sounds if all access relays are activated all doors open e Two short beeps sound if all access relays are deactivated all doors closed e One long beep sounds if there is a combination of access relays activated and deactivated some doors open some doors
22. able protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help 23 Tr CGESS 227354 B
23. aracters Press H Automatic Telephone Answer The factory setting will allow the system to detect a ring signal on the telephone line and answer the call NOTE The automatic answer feature can be turned off although remote programming remote access control by residents and resident call back features will no longer function 1 Press 6 1 4 2 Select the option for automatic telephone answering e Enter 0 to turn OFF automatic telephone answering e Enter 1 to turn ON automatic telephone answering 3 Press Speaker Chirp on Keystrokes The factory setting will cause the speaker to chirp when each key on the keypad is pressed Alternately the speaker chirp can be turned off 1 Press 6 2 4 2 Select the option for keystroke speaker chirps e Enter 0 to turn OFF the keystroke speaker chirps e Enter 1 to turn ON the keystroke speaker chirps 3 Press AR eHYN er Speaker Tone on Access Relay Activation The factory setting will cause the speaker to sound a tone for two seconds when the access relay is activated Alternately the tone can be turned off 1 Press 6 BE 2 Select the option for access relay activation tone e Enter 0 to turn OFF the access relay activation tone e Enter 1 to turn ON the access relay activation tone 3 Press 10 WELCOME DISPLAY TEXT PPN 57 57 LINE 1 LINE 2 LINE 1 UP TO 16 CHARACTERS TEXT LINE 2 UP TO 16 CHARACTERS TEXT FACTORY SETTING LINEAR ACCESS
24. e NOTE This step cannot be performed remotely through the telephone Press 2 2 E Enter the resident s Directory Code Press H NOTE To modify the name using all capital letters press H before entering the name 4 Modify the Name of the resident to be displayed up to 16 characters and press 4 or to keep the same name just press 4 5 Modify the residents Telephone Number up to 14 digits see how to enter pauses above and press E Or to keep the same Telephone Number just press t 6 Modify the resident s four digit Entry Code and press 4 or to keep the same Entry Code just press H Deleting an Existing Directory Entry Directory Entries can be deleted individually to delete all Directory Entries see programming Step 92 Press 2 3 E Enter the Directory Code Press H Enter the Directory Code again Press H a eer e Che GN DIRECTORY CODE LENGTH O2 4 LENGTH LENGTH NUMBER 2 3 OF DIRECTORY CODE DIGITS FACTORY SETTING 3 DIGITS ADDING A DIRECTORY ENTRY FOR A RESIDENT PPN 21 21 DIR NAME PHONE CODE CODE DIR DIRECTORY CODE FOR THE RESIDENT NAME THE RESIDENT S NAME UP TO 16 CHARACTERS PHONE THE RESIDENT S TELEPHONE NUMBER UP TO 14 DIGITS CODE ENTRY CODE FOR THIS RESIDENT 4 DIGITS CODE ENTRY CODE ENTERED AGAIN FOR VERIFICATION MODIFYING AN EXISTING DIRECTORY ENTRY PPN 22 22 DIR NAME PHONE CODE DIR DIRECTORY CODE FOR THE RESIDENT NAME T
25. e The lockout value can be from one to nine 1 Press 5 1 J 2 Enter the number for the lockout count 1 9 3 Press H Access Relay Activation Time The factory setting will cause the access relay to activate for 4 seconds The activation time can be set from 4 99 seconds to accommodate different types of access control devices 1 Press 5 2 4 2 Enter the time in seconds for access relay to stay activated 04 99 3 Press SYSTEM DISPLAY LANGUAGE S8 LANG LANG SYSTEM DISPLAY LANGUAGE 1 ENGLISH 2 SPANISH 3 FRENCH 4 PORTUGUESE FACTORY SETTING ENGLISH 51 COUNT COUNT NUMBER 1 9 OF INCORRECT ENTRIES THAT WILL CAUSE A 90 SECOND LOCKOUT FACTORY SETTING 3 TRIES 52 SECONDS SECONDS ACTIVATION TIME 04 99 SECONDS FACTORY SETTING 4 SECONDS p sim roc System Options Continued Welcome Display Text The AE 100 display will show a visitor a welcome message alternating with instructions on how to find and call a resident The welcome message can be customized to suit the installation NOTE This step cannot be performed remotely through the telephone Press 5 7 4 NOTE To enter capital letters only press E first before entering the text Enter the new text for the top line of the display up to 16 characters Press E NOTE To enter capital letters only press E first before entering the text Enter the new text for the bottom line of the display up to 16 ch
26. easy for installers familiar with Linear s and other manufacturer s access control systems two methods of programming are available Programming Position Numbers or Function Codes that match other equipment help the installer to make quick programming changes with keystrokes they ve used before Automatic Programming Method Selection The Programming Position Numbers or Function Codes change depending on the programming method used Refer to the table on Page 13 for the numbers used for each programming method The keys used to enter programming from the unit s keypad select which programming method is used for the current programming session Entering programming by pressing 0 amp 2 keys together will select the Standard Programming Method Linear Access style Details of each programming step when using the Standard Programming Method are shown on Pages 7 13 Entering programming by pressing 0 amp E keys together will select the Alternate Programming Method other manufacturer s style Details of each programming step when using the Alternate Programming Method are shown on Pages 15 21 o ano 2 TOGETHER FOR gt ror o ann TOGETHER FOR gt ALTERNATE PROGRAMMING METHOD lt q Programming from the Keypad Standard Method The system can be programmed using the keypad on the faceplate of the AE 100 The display w
27. es can be used e Up to eight seconds are allowed between each keystroke e All digits of the Entry Code must be entered gt Example The Entry Code length is four digits and the code is 0042 the user must enter 0 0 4 2 e f a mistake is made pressing the key will reset the keypad The correct code can then be re entered e f the number of incorrect codes entered exceeds the keypad lockout count the keypad will be locked and not accept any entries for 90 seconds Resident Call back If the resident call back feature is enabled resident s can call the AE 100 to talk to a visitor and grant access The call back must be made within 60 seconds after the visitor s missed call 1 The resident dials the telephone number of the system within 60 seconds of its last use 2 The system answers and sounds one short beep 3 After talking to the visitor the resident can press their entry code to grant access or the resident can press star to deny access 22 VISITOR ACCESS 1 IF THE VISITOR ALREADY KNOWS THE 5 lt RESIDENT S DIRECTORY CODE PRESS AND ENTER THE RESIDENT S DIRECTORY CODE THE SYSTEM WILL CALL THE RESIDENT OR 1 PRESS UP OR DOWN BUTTONS TO VIEW THE NAMES IN THE DIRECTORY HOLDING DOWN THE BUTTON MAKES THE DIRECTORY SCROLL FASTER 2 WHEN NAME IS FOUND PRESS THE CALL BUTTON THEN 1 AFTER THE CALL IS AN
28. h tenant for identification Name Up to 16 characters Telephone Number Up to 14 digits Access Code 4 digit code assigned to tenant for obtaining access with the keypad NOTES 1 Directory Codes can be set for 2 or 3 digits All Directory Codes will be the same length 2 A Directory Code cannot be duplicated 3 Each Directory Code represents one tenant 4 Delete unused Directory Codes to avoid running out of memory 5 Tenant Names can be entered in any order The system will display the Names in alphabetical order 6 The same Name Telephone Number and Access Code can exist with different Directory Codes LOCAL PROGRAMMING Step 1 Enter Function Code 01 then press EHTE DIR Step 2 Enter the new 2 or 3 digit Directory Code EHTER HAME Proceed to Step 3 If the Directory Code has already been used the display shows Return to Step 2 If the memory is full the display shows ROR DATA Return to Step 2 Enter the tenant Name up to 16 characters press after each character then again after the last character TELEFH HE Enter the tenant s Telephone Number up to 14 digits press after each number then again after the last number Press and hold down the 1 2 3 or 4 key for about two seconds to enter 1 4 two second pauses Note Each pause entered counts as one of the 14 Step 5 Enter the 4 digit Access Code Step 6 Press TELEPHONE PROGRAMMING
29. he Name and Directory Code for the desired resident Upon entering the Directory Code or pressing the button the AE 100 will automatically dial the resident s Telephone Number and establish two way voice communication between the visitor and the resident The resident will then have the option to grant or deny access to the visitor by pressing a digit on their telephone Residents simply enter their Entry Code for access In addition to the telephone entry the AE 100 can grant access at the keypad using up to 125 Stand alone Entry Codes not assigned to residents each Stand alone Entry Code used reduces the number of available Directory Entries by one For ADA compliance for the hearing impaired a visitor can connect their TTY device to the jack in the face of the system The visitor will be able to use their TTY device to communicate with the resident s TTY device during the telephone call Database Overview Programming the AE 100 involves entering installation information into the system s memory The system uses this information as a reference database to control the operation of the system Resident Directory Data Up to 125 resident Names Telephone Numbers and Entry Codes can be set Each resident entry is assigned a Directory Code Directory Codes can be two or three digits in length all will be the same length The Directory Code is the number a visitor would enter to have the system call the resident the resident cur
30. he Name press and skip to Step 5 To change the Name press then enter a new Name up to 16 characters press after each character then again after the last character To keep the Telephone Number press and skip to Step 7 To change the Telephone Number press then enter a new Telephone Number up to 14 digits press after each number then again after the last number Press and hold down the 1 2 3 or 4 key for about two seconds to enter 1 4 two second pauses Note Each pause entered counts as one of the 14 digits allowed in the telephone number ACCESS CODE CCURREMT CODE To keep the Access Code press To change the Access Code enter a new 4 digit Access Code then press Enter Function Code 03 then press TELETE DIR Enter the 2 or 3 digit Directory Code to delete then press IS DELETED If the Directory Code does not exist the display will show an error return to Step 1 ERROR OM DELETE Enter Function Code 04 then press DELETE ALL 13 Enter the number displayed then press ARE YOU SURE 3 Enter 5 for verification then press or press to cancel TELEPHONE PROGRAMMING NOT AVAILABLE Enter Function Code 03 and press one short beep sounds Enter the Directory Code 2 or 3 digits to delete and press two short beeps sound If you hear one long beep followed by two short beeps the Directory Code did not exist return to Step 1 NOT AVAILABLE
31. hone line to form a simple network Connecting multiple units allows transferring programming data either the directory entries only or the entire memory s contents from the master unit to the other sub units In multi unit installations each AE 100 must be assigned a unique unit number before programming The unit number allows connecting to a specific unit when calling for programming and identifies the other units to the master unit One unit must be assigned as Master Unit 1 Pre set Unit Numbers Your access control installation company has already programmed this system If this is a multiple unit installation the sub unit numbers have been set in the sub units and the master unit was also programmed to recognize those numbers 6 ACCESS DATA CONTROL a az 63 64 77 95 2 z 23 a 33 DELETE A STAND ALONE ENTRY CODE SYSTEM UTILITIES 30 34 81 83 92 93 DELETE ALL STAND ALONE ENTRY CODES LINEAR ACCESS TELEPHONE ENTRY romane Terere swen OOOO oo SPEAKER CHIRP ON KEYSTROKES G0 SECONDS OFF The unit numbers and locations for this installation are UNIT UNIT TYPE UNIT LOCATION vasten OOS sen CS 3 sunt o 4 s o p cio rasan no Resident Data Programming Up to 125 resident Names and Telephone Numbers can be set Each resident entry is assigned a Directory Code The Directory Code is the number visitors enter to have the system call the resident Visitors can also contact
32. ill show the programming information Accessing Programming from the Keypad 1 Press 0 amp 2 keys at the same time then release The display will show PASSWORD Enter the Master Password factory setting is 123456 Press m If the password is correct the display will show ENTER FUNCTION 6 Programming commands can now be entered on the keypad Refer to the following sections of this manual for programming step details Also refer to the figure for alphanumeric entry using the keypad Keypad Audio Prompts When programming using the keypad each programming step consists of entering programming data With the Standard Programming Method the system will sound beeps to indicate correct or incorrect entries e After a correct entry two short beeps will sound e After an incorrect entry one long beep will sound e After the complete programming step has been entered correctly three short beeps will sound Re entering a Command After a Mistake If an incorrect entry or an incorrect key is pressed during programming to clear the keypad press gt and start the programming step over again Exiting Programming Mode 1 Press NOTE The AE 100 will automatically exit Programming Mode after two minutes of programming inactivity af woh KEYPAD ALPHANUMERIC ENTRY FOR PROGRAMMING STEPS REQUIRING TEXT abc def ghi 2 5 8 jki stu y
33. inear Limited Warranty This Linear product is warranted against defects in material and workmanship for twenty four 24 months This warranty extends only to wholesale customers who buy direct from Linear or through Linear s normal distribution channels Linear does not warrant this product to consumers Consumers should inquire from their selling dealer as to the nature of the dealers warranty if any There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property revenue or profit or cost of removal installation or reinstallation All implied warranties including implied warranties for merchantability and implied warranties for fitness are valid only until the warranty expires This Linear LLC Warranty is in lieu of all other warranties express or implied All products returned for warranty service require a Return Product Authorization Number RPA Contact Linear Technical Services at 1 800 421 1587 for an RPA and other important details FCC Notice Changes or modifications not expressly described in this manual or approved by the manufacturer could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reason
34. ing Mode after five minutes of programming inactivity aPF woh 14 o ann TOGETHER FOR CONDITION AFTER AN INCORRECT ENTRY AFTER A CORRECT ENTRY OF AN INTERIM STEP AFTER A COMPLETE COMMAND HAS BEEN ENTERED CORRECTLY EXITING PROGRAMMING MODE ALTERNATE INTERFACE KEYPAD ALPHANUMERIC ENTRY FOR PROGRAMMING STEPS REQUIRING TEXT QZ qz0123 456789 ABCabc r ra GHIhgi 6 MNOmno TUVtuv PRSprs 9 wxvwey move to H next letter or finish DEFdef JKLjkl erase _ entire entry space ENTER AFTER EACH LETTER TO MOVE TO THE NEXT CHARACTER FINISH COMPLETE ENTRY BY ENTERING PRESS 8 THEN 0 TO BACKSPACE PRESS STAR TO ERASE ENTIRE ENTRY gt ALTERNATE PROGRAMMING METHOD lt j Alternate Programming Reference Refer to the following pages when programming using the Alternate Programming method For each of the following steps enter the Master Password and enter Programming Mode if the unit is not already in that mode Exit Programming Mode when all programming is complete FUNCTION CODE 01 PROGRAM A NEW TENANT There are four different fields that need to be programmed Directory Code Name Telephone Number and Access Code Directory Code A unique 2 or 3 digit code assigned to eac
35. q LOCAL PROGRAMMING Enter Function Code 31 then press ACCESS CODE Enter the new 4 digit Stand alone Access Code then press ACCESS CODE Enter the new 4 digit Stand alone Access Code again for verification Press Enter Function Code 33 then press Enter the 4 digit Stand alone Access Code to delete then press ACCESS CODE Enter the 4 digit Stand alone Access Code to delete again for verification Press Enter Function Code 34 then press UHITS Enter the number s 2 3 and or 4 of all the sub units to copy the data to then press ARE YOU SURE 7 3 Enter 5 for verification then press OR Enter to cancel this command The installer must setup the system as a multi unit installation before this command will operate Enter Function Code 38 then press Enter 1 for English Default 2 for Spanish 3 for French 4 for Portuguese Press TELEPHONE PROGRAMMING Enter Function Code 31 and press one short beep sounds Enter the new 4 digit Stand alone Access Code press one short beep sounds Enter the new 4 digit Stand alone Access Code again for verification Press two short beeps sound Enter Function Code 33 and press one short beep sounds Enter the 4 digit Stand alone Access Code to delete press one short beep sounds Enter the 4 digit Stand alone Access Code to delete again for verification Press two short beeps sound
36. rently displayed can also be contacted using the button Each resident data entry also includes the resident s Telephone Number and a unique Entry Code for that resident RESIDENT DIRECTORY DATA UP TO 125 RESIDENTS FOR EACH RESIDENT DIRECTORY CODE 2 OR 3 DIGITS NAME UP TO 16 CHARACTERS TELEPHONE UP TO 14 DIGITS ENTRY CODE 4 DIGITS Stand alone Entry Code Data Up to 125 Stand alone Entry Codes Entry Codes are called Access Codes when using the alternate programming method that are not assigned to a resident s directory listing can be set These types of Entry Codes are useful for service and maintenance personnel Each Stand alone Entry Code programed reduces the available number of resident directory entries by one Stand alone Entry Codes are four digits in length When a Stand alone Entry Code is entered at the keypad it will activate the access relay STAND ALONE ENTRY CODE DATA UP TO 125 CODES FOR EACH CODE STAND ALONE ENTRY CODE 4 DIGITS NOTE EACH STAND ALONE ENTRY CODE REDUCES THE AVAILABLE NUMBER OF RESIDENT DIRECTORY ENTRIES BY ONE System Features OPTIONAL CABINET CCTV MICROPHONE CAMERA LOCK DISPLAY OPTIONAL POSTAL LOCK j KEYPAD SPEAKER LIGHTING KEYPAD Your access control installation company has set this Master Password for this installation Use this password to enter programming mode Access to Programming To make it
37. rogramming Mode NOTE The AE 100 will automatically exit Programming Mode after two minutes of programming inactivity e To exit programming when using the Standard Programming Method press 9 9 e To exit programming when using the Alternate Programming Method press 9 1 EJ CONNECTING WITH A TELEPHONE 1 CALL THE SYSTEM 2 SYSTEM ANSWERS ON THIRD RING 3 SYSTEM SOUNDS THE CURRENT STATUS gt ONE SHORT BEEP ALL RELAYS ON gt TWO SHORT BEEPS ALL RELAYS OFF gt ONE LONG BEEP RELAYS MIXED ON amp OFF 4 ENTER THE UNIT NUMBER 1 4 AND PRESS FOR SINGLE UNIT INSTALLATIONS ENTER 1 5 ENTER THE MASTER PASSWORD DEFAULT PASSWORD IS 123456 6 TO USE STANDARD PROGRAMMING PRESS TO USE ALTERNATE PROGRAMMING PRESS STAR 7 BEGIN PROGRAMMING ENTER STEP NUMBER FOLLOWED BY CONDITION AFTER AN INCORRECT ENTRY AFTER A CORRECT ENTRY OF AN INTERIM STEP AFTER A COMPLETE COMMAND HAS BEEN ENTERED CORRECTLY EXITING PROGRAMMING MODE gt i press 9 9 p em press 9 1 Programming Reference amp Factory Defaults STANDARD ALTERNATE PROGRAMMING FUNCTION POSITION CODE Sie NUMBER NUMBER __t__emr noon uuu Fs SYSTEM OPTIONS FACTORY FUNCTION OF PROGRAMMING STEP Sz N 10 WELCOME DISPLAY TEXT RESIDENT CALL BACK Multi unit Installations Up to four AE 100 units may be connected to the same dedicated telep
38. rt the command Copy All Data from Master to Sub units To synchronize programming in multi unit installations all system data can be copied from the master unit to selected sub units This data includes the Directory Entries Stand alone Entry Code data and all system option settings except the sub unit number and password NOTE The installer must setup the system as a multi unit installation before this command will operate NOTE This utility command can only be performed from the master unit A CAUTION This utility command will overwrite ALL the data in the selected sub units 1 Press 3 4 4 2 Enter the unit number s of all of the sub units to receive the full data set Examples e To copy to unit two only enter 2 4 e To copy to unit three only enter 3 7 e To copy to units two amp three enter 2 3 e To copy to units two three and four enter oag 3 To execute the command enter 5 4 or enter 5k to exit any other entry will abort the command 12 COPY ACCESS DATA ONLY FROM MASTER TO SUB UNITS PPN 30 30 SUB UNITS 5 SUB UNITS EACH SUB UNIT NUMBER 2 4 TO COPY ACCESS DATA TO IN A MULTI UNIT INSTALLATION NOTE TO ALLOW FOR MULTI UNIT NETWORK COMMUNICATIONS WHEN EXECUTING THIS COMMAND REMOTELY OVER THE TELEPHONE THE SYSTEM WILL DISCONNECT YOUR CALL AFTER STEP 3 THEN COPY THE DATA FROM THE MASTER UNIT TO THE SUB UNITS COPY ALL DATA FROM MASTER TO SUB UNITS PPN 34 34 SUB UNITS
39. the resident s name and Directory Code number they can press to call the resident e The system dials the resident s Telephone Number to establish 2 way communications NOTE The resident s Telephone Number will never be displayed to the visitor e The resident answers the call and converses with the visitor to determine if access should be granted e The resident can use their telephone s keypad to grant access activating the access relay by pressing 9 After access is granted the system will disconnect the visitor and resident call e The resident can disconnect the visitor without granting access by pressing k or by hanging up NOTE Disconnecting by hanging up is not recommended The system will keep the telephone line seized until the maximum visitor talk time timer runs out the factory default is 60 seconds e The length of time the visitor is allowed to talk can be programmed from 10 180 seconds At ten and five seconds before the disconnect a tone will sound on the telephone to remind the resident of the pending disconnect To restart the talk timer the resident can press 4 on their telephone Requesting Access with an Entry Code Residents and authorized personnel have up to 40 seconds to key in their Entry Code 1 Press gt first to clear the keypad optional then enter the Entry Code 2 When a correct code is entered the access relay will activate e Directory Entry Codes or Stand alone Entry Cod
40. ther manufacturer s style Details of each programming step when using the Alternate Programming Method are shown on Pages 15 21 Alternate Audio Prompts The audio prompts that give feedback during programming at the unit s keypad or over the telephone are different for the Alternate Programming Method Those differences are shown in the table to the right Alternate Alphanumeric Entry When the keypad is used for alphanumeric data entry in the alternate programming mode each key enters data differently than the standard interface mode See the keypad figure to the right Alternate Programming Access from the Keypad 1 Press 0 amp H keys at the same time then release The display will show Master Code Enter the master code factory setting is 123456 The display will show asterisks as the code is entered If the master code is incorrect the system will sound two long beeps and return to normal operating mode 6 If the password is correct the display will show SELECT FUNCTION 7 Programming commands can now be entered on the keypad Refer to the following pages in this manual for Alternate Programming Method step details Re entering a Command After a Mistake If an incorrect entry or an incorrect key is pressed during programming to clear the keypad press gt and start the programming step over again Exiting Alternate Programming Mode 1 Press 9 1 E NOTE The AE 100 will automatically exit Programm
41. urned off although remote programming remote access control by residents and resident call back features will no longer function 75 SPEAKER CHIRP ON KEYSTROKES The factory setting will cause the speaker to chirp when each key on the keypad is pressed Alternately the speaker chirp can be turned off 76 SPEAKER TONE ON ACCESS RELAY ACTIVATION The factory setting will cause the speaker to sound a tone for two seconds when the access relay is activated Alternately the tone can be turned off al RESIDENT CONTROL OF ACCESS RELAY The factory setting allows the resident to activate the access relay by pressing the 9 key on their telephone when a call from the AE 100 is received This feature can be disabled Disabling this feature will only allow access by using resident Access Codes and Stand alone Access Codes at the unit s keypad 20 p gt ALTERNATE PROGRAMMING METHOD lt q LOCAL PROGRAMMING Enter Function Code 74 then press The display will show the auto answer setting Enter 0 to disable auto answer Enter 1 to enable auto answer default Press Enter Function Code 75 then press BEEP OM 1 OFF 8 Enter 0 to turn the keystroke chirps OFF Enter 1 to turn the keystroke chirps ON default Press Enter Function Code 76 then press UHLOCK BEEPS 1 6 Enter 0 to turn the relay tone OFF Enter 1 to turn the relay tone ON default Press Enter Function Code

Download Pdf Manuals

image

Related Search

Related Contents

マルチカメラコントローラー 取扱説明書  Dale Tiffany TW100851 Installation Guide  eSpring® Carbon WTS Owner`s Manual  Samsung GT-B7510 Benutzerhandbuch  R167-14_E-Mail, MSC Chile.- Cartas de temperatura Puerto  Idrosanitaria  EXCLUSIVAMENTE PARA PESSOAL DE SERVIÇO  取扱説明書TRXショートフェン・  VL FOREVER 630-625-635 PRO - M0S10308 2T06 BOZZA  DeLOCK 1m VGA Cable  