Lightolier Calculite IS-PE User's Manual
Contents
1. 1 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0608 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Calculite IS PE Page 4 of 5 Instruction Sheet for Assembly and Installation of ProSpec Linear Series E ADJUST HOUSING Flanged Aperture Frame Adjust Housing at Mounting Brackets so that bottom edge is flush with finished ceiling as shown Fig 5 oe LAL ieee Ceiling Figure 5 INSTALL APERTURE FRAME Step 1 Aperture Frame Installation A MR16 a Insert Plug Connectors from sockets into receptacles on inside wall of housing b Connectors are polarized and therefore may only be inserted in one direction c Make sure connectors snap firmly into space Fig 6 Step 2 A Hook tortiontite Springs into slots of housing B Push Aperture Frame upward Fig 7 Receptacle Connector ere fe Tortiontite Springs Socket S A Plug Connector Housing Slot Apperture Frame Figure 6 Figure 7 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0608 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Calculite IS PE Page 5 of 5 Instruction Sheet for Assembly and Installation of ProSpec Linear Series E INST
2. 5 Cat No PE2M16 10 25 40cm 5 12 70cm 1 5 PE3M16 15 38 10cm 5 12 70cm 2 25 PE4M16 20 50 80cm 5 12 70cm CAUTION Turn power off before lamping fixture Wait until fixture is cool before touching 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0608 Lightolier is a Philips group brand PHILIPS
3. ALL LAMP AND ACCESSORIES Step 1 Install Lamp Fig 8 A Before relamping make sure that the power is off and the fixture cooled off sufficiently to touch B Remove Aperture Baffle from fixture by pulling straight out of Housing C Connect Lamp to Socket by inserting pins on Lamp into holes in Socket inside Housing Note Care should be taken not to touch the inside of lamp No polarity of pins is required D Lamp wattage 75W maximum Lamp will center itself with three 3 Lamp Springs A Glass Lamp Guard must always be used in this fixture E Replace Aperture Baffle by pushing it into the housing Step 2 Install Accessories A To Install lens accessory that ordered separately remove at least one 1 Lamp Spring and Screw and loosen the other two 2 Remove Glass Lamp Guard and replace with lens accessory Replace Lamp Spring and tighten screws Fig 9 Color filters can be used as a Lamp Guard B To Install hex cell louver that ordered separately remove Glass Lamp Guard place Louver flat against Aperture Baffle top surface Replace Glass Lamp Guard Color filters can be used in place of Glass Lamp Guard Lamp Spring A Glass Lamp Guard 1 VAR Lamp Spring Socket A O Glass Lamp Guard A i Figure 8 Aperture Baffle Figure 9 Aperture Baffle Aperture Housing Opening Electrical Ratings Length Width Input Amps PE1M16 5 12 70cm 5 12 70cm 7
4. LIGHTOLIER Calculite IS PE Page 1 of 5 Instruction Sheet for Assembly and Installation of ProSpec Linear Series E READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE PROCEEDING RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE This fixture is intended for installation in accordance with the National Electrical Code and local regulations To assure full compliance with local codes and regulations check with your local electrical inspector before installation To prevent electrical shock turn off electricity at electrical panel before proceeding DO NOT INSTALL THIS SYSTEM IN A WET LOCATION CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY REINFORCING CEILING TO SUPPORT FIXTURE WEIGHT Adjustable Mounting Bracket Housing 45 Beveled Flanged 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0608 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Calculite IS PE Page 2 of 5 Instruction Sheet for Assembly and Installation of ProSpec Linear Series E Warning for All Fixtures Use only aperture frames and accessories provided by Lightolier Inc Use of other manufacturers aperture frames and accessories voids the Unde
5. hilips group brand PHILIPS LIGHTOLIER Calculite IS PE Page 3 of 5 Instruction Sheet for Assembly and Installation of ProSpec Linear Series E FRAME IN AND WIRE Step 1 Install Housing using Adjustable Mounting Brackets A Fixture must be secured to structural ceiling members If no ceiling access available fixtures must be installed before ceiling material With Mounting Bar Lightolier Cat No 1951 use rectangular slots Fig 1 With 1 2 1 27cm EMT by others Fig 2 With 3 4 1 91cm or 1 1 2 3 81cm Channel by others Fig 3 For Suspended T Bar Ceilings use Lightolier Cat No 1956 to secure 1951 Mounting Bars to ceiling runners Fig 4 F To install with hanging wires by others consult installation from hanging wire manufacturer Adjustable Mounting Bracket FTE Cn 0 ae Mounting Bar 1 2 1 27cm Order Separately 1951 EMT By Others 3 4 1 91cm or Screw Screw Screw 1 1 2 3 81cm Channel By Others Figure 1 Figure 2 Figure 3 Anchor Cli Mounting Bar Order e 1956 Order Separately 1951 A a Figure 4 Step 2 Connect Supply Leads White fixture lead to neutral white supply black fixture lead to hot supply lead bare fixture wire to supply ground Use wire nuts for all connections local hardware items Step 3 Place all electrical connections in J Box attached to side of fixture Step 4 Attach J Box Cover onto J Box attached to side of fixture 63
6. rwriters Laboratories Listing and could constitute a fire hazard Caution Risk of Fire Use proper lamp wattages with corresponding ballast wattages Check ballast module wattage label to confirm wattage Caution Risk of Burn Allow time for luminaire to cool before attempting to relamp or position Caution Risk of Burn and Electrical Shock Turn off power to Ballast Module before servicing All PowerArc Modular Ballasts are equipped with a power switch Depressing Dot on Switch is the ON position See IS 83B Note 1 Low voltage fixtures may produce audible sound when used with dimmers which maybe objectionable in acoustically critical areas 2 For HID Fixtures HID lamps require a warm up period of 5 10 minutes to reach full output Additionally when these lamps are extinguished they must cool for 5 15 minutes before they will relight Outage can be caused by momentary power failure substantial voltage reduction or cycle changes Warning for MR16 Fixtures Only Lamp manufacturers require the glass lamp guard be in place before energizing lamp and that great care must be taken that lamp is fully cooled before relamping Avoid finger marks on inside of lamp for they may cause short lamp life and possible breakage 631 Airport Road Fall River MA 02720 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0608 Lightolier is a P
Download Pdf Manuals
Related Search
Related Contents
Samsung MAX-DN65G Инструкция по использованию PST-100HL - User manual 取扱説明書 - GENTOS Speciale Speciale Soluzioni di motion control e MANUEL D ` UTILISATION DU MODULE ANNUAIRE MODULE AVerVision 355AF User Manual DOSSIER DE DEMANDE D ` I N S C R I P T I O N FAG-Alignment Tools Top-Laser: SMARTY2 ∙ TRUMMY2 ∙ INLINE Rules - Amazon Web Services Performance Watch User Guide Copyright © All rights reserved.