Home
Lathem LTR-RSS User's Manual
Contents
1. LTR RSS REMOTE SCHEDULE SELECTOR and BELL RINGER Installation amp User s Guide THIS EQUIPMENT COMPLIES WITH FCC CLASS B REQUIREMENTS PURSUANT SUBPART J OF PART 15 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna
2. Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numerique de la classe B est conforme a la norme NMB 003 du Canada OPERATION INSTALLATION AND MAINTENANCE MANUAL REMOTE SCHEDULE SELECTOR and BELL RINGER LATHEM TIME CORP Doc USG0026B LTR8 512 LTR RSS and MasterLink are Registered Trademarks of Lathem Time Corp Atlanta GA USA 2004 LATHEM TIME CORP LTR RSS User s Guide Welcome to the LTR RSS Remote Schedule Selector Bell Ringer The Remote Schedule Selector Bell Ringer for the LTR8 512 Master allows you to immediately activate any one 1 of the eight 8 possible schedules stored in the Master or deactivate all schedules Your selection remains in effect until you make another schedule change at the LTR RSS the MasterLink Software or the Master itself or when a programmed schedule change occurs The Remote Schedule Selector Bell Ringer contains an electronic circuit attached to the back of a cover plate for a double gang switch type electrical box not supplied This circuit consists of a low power microprocessor a 4 screw terminal block and dip switches to select your Master s address and baud rate Two o
3. switches 7 and 8 2 1 3 For address 102 slide down switches 2 3 6 and 7 64 32 4 2 102 Locate the terminal block on the back of the circuit board upper left Attach the communication cable wire pair with proper polarity to the top two screws on the terminal block The top screw is Data and the next one down is Data LTR RSS User s Guide Connect low voltage power to the lower 2 screws on the terminal block The LTR RSS requires a voltage source of 9 to 24 volts AC or DC If the distance between the LTR8 512 Master and the LTR RSS is less than 100ft you can use a 2nd twisted pair in the cable to bring power from the Master Terminals 12 and 13 on the rear of the Master s Display Panel providing 12vAC at 250mA You should use a separate low voltage power supply or transformer if the cable would be longer than 100 feet or placed in areas of electrical interference that can cause problems for the Master You should also place an in line 250ma fuse on this connection Secure the cover plate to the electrical box with four 6 32 FH screws LTR RSS User s Guide Wiring Diagram LTR8 512 Master 24VAcIDC TI Communications Connector Power Supply heng Module Bell Schedule Selector Note The Bell Schedule Selector may be located up to 4000 feet from the LTR8 512 Master 10 LTR RSS User s Guide RS 485 Cable Power Cable 9 24 VAC Install Diagram _ Cable Plug
4. ba p get marone Soe R Ka 4 7 A 11 LTR RSS User s Guide Using the LTR RSS When you make a schedule change this change remains in effect until you make another change or when a programmed schedule change occurs You can make schedule changes at the LTR RSS the MasterLink software or the Master itself To deactivate all schedules e Turn the knob to the ALL OFF position e Push the ENTER SELECTION button All LED s will flash briefly and all schedules are deactivated 12 LTR RSS User s Guide To activate a schedule Turn the knob to choose which schedule you want to activate After turning the knob push the ENTER SELECTION button The indicator LED will light to show which schedule is now active The LED stays lit for five 5 seconds then turns off to conserve power All schedules other than the one you chose are now deactivated 13 LTR RSS User s Guide To manually ring all bells e Turn the knob to the RING BELLS position e Push the ENTER SELECTION button All bell circuits will become active and will remain active for as long as you press the ENTER SELECTION button Note The bell circuits could remain active up to 2 seconds after releasing the ENTER SELECTION button 14 Limited One Year Limited Warranty Lathem warrants the hardware products described in this guide against defects in material and workmanship for a period of one year from date of original purc
5. e Mechanical Environmental Circuit board is mounted to an industry standard double gang switch plate Plate is screwed into standard double gang flush mount electrical box typically Wire Mold Part ft V5747 2 not included Connection of cables between electrical box and LTR8 512 or power source should be through conduit or other means approved by electrical fire codes for low voltage wire Operation 0 85 C 32 185 F 20 60 R H non condensing LTR RSS User s Guide Installing the LTR RSS To install the Remote Schedule Selector Bell Ringer e Remove the LTR RSS from its package and locate the dip switches bottom center on the back of the circuit board e Set the dip switches to ON match the Master s 2456 address default 65 9600 and baud rate Press at the Master to see its current address and baud rate Hulslelafel 2345 6 7 8 x N or 64 32 16 BAUD W The legend on the circuit board will help you know which way to slide the dip switches Use switch 1 to set the Baud Rate Slide it down to choose 9600 baud default and up to select 2400 baud 7 LTR RSS User s Guide To select the address use the numbers that add up to equal the number of your Master s address then slide those switches down For example the default address is 065 switch 2 value of 64 and switch 8 value of 1 are down 64 1 65 For address 003 slide down
6. f the screws on the terminal 1 LTR RSS User s Guide block connect a twisted pair typically Cat 3 low voltage cable to the Master s RS 485 port while the other two screws connect continuous 9 24V AC DC power to the unit Circuit Board GORRORSG LTR RSS User s Guide On the face of the cover plate you will see a 10 position knob to select which schedule you want active a button to send your changes to the Master and status lights which confirm that your changes occurred EC A ESI DUL AEMOTE EN RINGE gp p LTR RSS User s Guide Specifications Power Input 9 24V AC DC 1W max For cable between the LTR RSS and LTR8 512 less than 100 ft power can be drawn from the 12V output on the LTR8 512 s I O connector For longer cable power should be drawn from a bell transformer or Lathem 24V power supply typically a PS8 24 Low voltage wire is recommended LTR RSS User s Guide Communications Terminal Block EIA IEEE RS 485 half duplex requiring single twisted pair UTP or STP communications cable typically CAT 3 or CAT 5 Max length 4000 ft Can be included on LTR8 512 s RS 485 Host Communications Bus along with other Lathem RS 485 devices 4 screw removable terminal plug supports both power 2 wire andcommunications 2 wire connections Requires 3 32 flat head screwdriver LTR RSS User s Guid
7. hase from Lathem or from an authorized Lathem reseller The conditions of this warranty and the extent of the responsibility of Lathem Time Corporation Lathem under this warranty are listed below 1 This warranty will become void when service performed by anyone other than an approved Lathem warranty service dealer results in damage to the product This warranty does not apply to any product which has been subject to abuse neglect or accident or which has had the serial number altered or removed or which has been connected installed adjusted or repaired other than in accordance with instructions furnished by Lathem This warranty does not cover dealer labor cost for removing and reinstalling the machine for repair or any expendable parts that are readily replaced due to normal use The sole responsibility of Lathem under this warranty shall be limited to repair of this product or replacement thereof at the sole discretion of Lathem If it becomes necessary to send the product or any defective part to Lathem or any authorized service dealer the product must be shipped in its original carton or equivalent fully insured with shipping charges prepaid Lathem will not assume any responsibility for any loss or damage incurred in shipping WARRANTY DISCLAIMER AND LIMITATION OF LIABILITY Except only the limited express warranty set forth above the products are sold with no expressed or implied warranties of any kind and t
8. he implied warranties of merchantability and fitness for a particular purpose are hereby expressly disclaimed No warranties are given with respect to products purchased other than from Lathem or an authorized Lathem reseller and any such products are purchased as is with all faults In no event will Lathem be liable for any direct indirect special incidental or consequential damages arising out of or in connection with the delivery use or inability to use or performance of this product In the event any limited remedy given herein shall be deemed to have failed of its essential purpose Lathem s maximum liability shall be to refund the purchase price upon return of the product Proof of date of purchase from Lathem or an authorized Lathem reseller is required for warranty service on this product This Warranty grants specific legal rights Additional legal rights which may vary by locale may also apply Should any difficulties arise with the performance of this product during warranty or with any Lathem authorized service centers contact Lathem Time at the address below Lathem Time 200 Selig Drive SW Atlanta GA 30336 404 691 0405 www lathem com Copyright 2004 Lathem Time Corporation All rights reserved
Download Pdf Manuals
Related Search
Related Contents
Sunpentown Intl SO-2000 User's Manual User Manual - SharePoint On the Privacy of Real-World Friend-Finder Services norme cei internationale iec international 60576 REDUCTOR DE TENSIÓN CONTÍNUA (24V – 12V / 10.5 Amper) COMMISSION DE L`INTÉRIEUR, DES AFFAIRES Bedienungsanleitung Tareo 22 Katalog PDF - marlies S3FI1BG User`s Manual Copyright © All rights reserved.
Failed to retrieve file