LaCie 12big User's Manual
Contents
1. Quick Install Guide 10 Installing Drives CAUTION All drive bays must be fitted with either a drive carrier or dummy carrier module No bays should be left empty Column 1 Column 2 Column 3 Column 4 Row 1 1 de Drive BE Row 2 J D gus Dr ive ri Row 3 Brive 10 vir 44 Figure 16 Bay Number Definition The 12big rack serial enclosure system supports SAS and SATA drives However mixing of drive types within a single enclosure is not supported The enclosure has no restrictions on drive location 1 Ensure the anti tamper lock is disengaged see Figure 15 2 Release the carrier handle by pressing the latch in the handle towards the right and insert the carrier into the enclosure 3 Gently slide the carrier all the way into the enclosure until it is stopped by the camming lever on the right of the carrier see Figure 16 Indicator Aperture IC LOCKED UNLOCKED Anti Tamper Lock Figure 17 Drive Anti Tamper Lock Figure 18 Installing a Drive Carrier 1 4 The camming foot on the base of the carrier will engage into a slot in the enclosure Continue to push firmly until the handle fully engages A click should be heard as the latch engages and holds the handle closed see Figure 17 Installing Drives Power On 1 O Module page 8 5 Carefully insert the anti tamper lock key provided into the cutout in the handle and rotate the key in a clockwise direction until the red indicator is visible in the aperture
2. beside the key see Figure 15 Figure 19 Installing a Drive Carrier 2 11 Power On Power on the storage system by connecting the power cables to the power distribution unit PDU powering on the PDU moving the PSU switches to the ON position and then power ing on the host system All LEDs on the Ops Panel should illuminate and the alarm will beep momentarily when power is activated Wait for one minute before accessing the system s Power Distribution Units AC UPS Figure 20 Connecting the AC Power Cables to the PDU 12 I O Module Activity LEDs Reserved For Future Use Fault LED ID LED Figure 21 LO Module LaCie 12big rack serial Quick Install Guide Ops Panel LEDs 5 gt 3 3 T E D Ou DO U H a E D E x Other K Si eo Associated LEDs or Alarms 12big rack serial Module activity LEDs flash I O Module page 9 State Description Ops Panel power on test state any any Continuous beep any any Dual Fan Cooling Module Fault LED on Power On All functions good Dual Fan failure Intermittent beep Flash any any Dual Fan Cooling Module Fault LED on Single Fan failure Intermittent beep Flash any any PSU Module Fault LED on Single PSU failure Continuous beep any any Intermittent beep PSU removed any any Intermittent beep Over
3. home position and attach it to the rack using the captive fasteners on the front flanges 4 i 4 4 4 Figure 4 Mounting the System into a Rack 5 Installing Modules Fit the modules into the bays defined in Figure 5 ci Dual Fan J j PSUO PSU1 Cooling Module HO Module 0 Figure 5 Module Locations Mounting the System Installing Modules Installing the PSU Modules page 5 6 Installing the PSU Modules WARNING Do not mix PSUs of different types or makes CAUTION Handle the module carefully and avoid damaging the connector pins Do not install if any pins appear to be bent IMPORTANT To prevent overheating do not operate the enclosure for more than 30 minutes with one PSU removed 1 Check for damage especially to the rear connector of the PSU 2 Slide the PSU into the enclosure see Figure 6 3 Continue to push the PSU until it fully seats A click should be heard as the handle latch engages 4 Connect the power cables to the power source and to the PSU 5 Engage the retaining spring Note The alarm will sound until the PSU is operating correctly Figure 6 Installing the AC Power Supply Module LaCie 12big rack serial Installing the Dual Fan Installing the LO Modules Quick Install Guide page 6 7 Installing the Dual Fan 8 Installing the 1 0 Modules Cooling Module IMPORTANT H only one I O module is fitted it must be installed into the lower Slot O locati
4. or under temperature warning any any Continuous beep Over or under temperature critical any any Continuous beep Voltage critical Off As per Drive fault any None Drive critical LED Off As per Drive fault any None Drive non critical LED any any 12big rack serial Fault amp ID LEDs on 12big rack serial Module watchdog failure Internittent beep Flash any any 12big rack serial Fault amp ID LEDs on 12big rack serial Module soft or POST failure Intermittent beep Flash any any 12big rack serial Fault amp ID LEDs on Other 12big rack serial Module fault LED operation set via SES Control page 0x02 any Off any As per Drive fault Drive Bay Fault LED flash LED Power On All functions good POST fault bit set for any Array Device Element any As per Drive fault any Drive Bay Fault LED flash LED Other Array bits set for any Array Device Element any Continuous beep Intermittent beep UNRECOYV bit set in Audible Alarm element INFO NON CRIT CRIT bits set in Audible Alarm element Continuous beep UNRECOV bit set in Audible Alarm element REQUEST WARNING bit set in Enclosure element REQUEST FAILURE bit set in Enclosure element Notes 1 The 12big rack serial alarm pattern is a 1 second on 1 second off sequence applied to all 12 Activity LEDs 2 H an 12big rack serial fault LED is fitted this
5. 3 59 Stockholm Sweden sales nordic lacie com LaCie Spain C N ez Morgado 3 5 pl 28036 Madrid sales es lacie com LaCie Switzerland Davidsbodenstrasse 15 A 4004 Basel sales ch lacie com LaCie United Kingdom and Ireland LaCie LTD Friendly House 52 58 Tabernacle Street London England EC2A 4NJ UK sales uk lacie com Ireland sales ie lacie com LaCie Worldwide Export 17 rue Amp re 91349 Massy Cedex France sales intl lacie com Visit www lacie com for more information on LaCie products Made for ideas Copyright 2009 LaCie 713355 090529
6. LaCie 12big rack serial Table of Contents Quick Install Guide page 1 EN English Table of Contents Te HEF OCUCIION WEE 2 IN E EE 2 ENEE 2 3 IS e ER De EE 3 Prenar ON ER 3 AR CN 3 3 Unpackaging the Storage System ue 3 4 Mounting the System into the Rack sscsscsscsccscsscsscsccsccscsscscsscsccssescsscssescesess 4 5 EE Te EE EN 5 6 Installing the PSU Modules essesesesesosossesesossececesesescesesesesososcessssssesecesesesoesesesesos 5 7 Installing the Dual Fan Cooling Module cccsscsscscssccscsccsccscescsscscescsscscsscescsees 6 8 Installing the 1 0 Modules csccscsccscsccscsccscsccscecsccecsccscscssceccscscsscecsccsceceees 6 7 9 Connecting Storage System to Host cccsccscsccscsccscsccscscsscscsscscescscesscssescesescsceees 7 TO IRON RTE 8 Ti Power e E 8 1A VO OO ER 8 9 LaCie 12big rack serial Quick Install Guide 1 Introduction European Regulations This equipment complies with European Regulations EN 55022 Class A Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipments and EN50082 1 Generic Immunity USA Federal Communications Commission FCC This equipment has been tested and found to comply with the limits for a class A digital device pursuant to part 15 of the FCC rules 1 1 Safety All plug in modules and blank plates are part of the fire enclosure and must only be removed when a r
7. akage current from all the power supplies in all the units The rack may require labelling with HIGH LEAKAGE CURRENT Earth connection essential betore connecting supply e The rack when configured with the units must meet the safety requirements of UL 60950 1 and IEC 60950 1 LaCie 12big rack serial Quick Install Guide WARNING Do not remove covers from the PSU Danger of electric shock inside Return the PSU to your supplier for repair CAUTION If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired 1 3 ESD Precautions It is recommended that you fit and check a suitable anti static wrist or ankle strap and observe all conventional ESD precautions when handling LaCie 12big rack serial plug in modules and components Avoid contact with backplane components and module connectors etc 2 Preparation 2 1 Before You Begin Before you begin make sure the site where you intend to set up and use your storage system has the following e Standard AC power from an independent source or a rack power distribution unit with a UPS e Host computer with the correct firmware BIOS and drivers Contact your supplier for the correct software levels The Accessory Box contains the power cables and other ordered accessories Before setting up your enclosure ensure you have the following e SAS HBA e Mini SAS to Host Cable e Power Cable e Rack kit
8. ction to meet the requirements laid down in the technical specification 1 2 Rack System Precautions The following safety requirements must be considered when the unit is mounted in a rack e The rack design must incorporate stabilizing features suitable to prevent the rack from tipping or being pushed over during installation or in normal use e To avoid the danger of the rack tipping over do not slide more than one enclosure out at once e When loading a rack with the units fill the rack from the bottom up and empty from the top down e The rack design should take into consideration the maximum operating ambient temperature for the unit which is 40 C e The system must be operated with low pressure rear exhaust installation back pressure created by rack doors and obstacles not to exceed 5 pascals 0 5mm water gauge e The rack must have a safe electrical distribution system lt must provide over current protection for the unit and must not be overloaded by the total number of units installed in the rack Consideration of the electrical power consumption rating shown on the nameplate should be used when addressing these concerns e The electrical distribution system must provide a reliable earth for each unit in the rack e Each power supply in each unit has an earth leakage current of 1 5mA max at 60Hz 264VAC per PSU The design of the electrical distribution system must take into consideration the total earth le
9. eplacement can be immediately added The system must not be run without all modules in place Permanently unplug the unit if you think that it has become damaged in any way and before you move it e The enclosure can weigh up to 32kg 70 4lb Do not try to lift it by yourself e Do not lift a populated enclosure by the module handles or those on the front of the enclosure they are not designed to support the weight of the populated enclosure e In order to comply with applicable safety emission and thermal requirements no covers should be removed and all bays must be fitted with plug in modules e The enclosure must only be operated from a power supply input voltage range of 100 120VAC or 200 240VAC e The power supply is used as the main disconnect device Ensure that the socket outlets are located near the equipment and are easily accessible e The equipment is designed to be operated with two working power supply modules e To prevent overheating do not operate the enclosure with one power supply removed for more than 30 minutes e Disconnect all supply power for complete isolation Introduction page 2 e The power connection should always be disconnected prior to removal of the Power Supply module from the enclosure e A safe electrical earth connection must be provided to the power cords Check the grounding of the enclosure before applying power e Provide a suitable power source with electrical overload prote
10. if installing within a rack Refer to your supplier for a list of qualified accessories for use with the enclosure Introduction Preparation Unpackaging page 3 3 Unpacking the Storage System Position the shipping packaging within reasonable distance of the site where you intend to install the storage system Inspect the packaging for crushes cuts water damage or any other evidence of mishandling during transit If any damage appears to be present it is suggested to take photographs before opening any boxes You may wish to contact the shipping company if there is apparent damage Open the carton top and remove the accessory kit Remove the foam component on top of the enclosure Using an assistant lift the enclosure from the carton and place it on a stable work surface Rail Kit Optional CD Optional Cables Optional Figure 1 Unpacking the Storage System Populated Enclosure LaCie 12big rack serial Mounting the System into the Rack Quick Install Guide page 4 4 Mounting the System into the Rack 1 Remove the Rack Mounting Rail Kit from the Accessory Box and check for damage Attach the left and right chassis slides to the enclosure sides using six M3x4 but ton head screws Three screws each side see Figure 2 for locations 2 Attach left and right chassis slides to the enclosure sides using 8 M3 x 4 buttonhead screws see Figure 2 3 Assemble the left and right chassis latches u
11. on otherwise direct SATA CAUTION Handle the module carefully and avoid damaging ln wark the connector pins Do not install if any pins appear to be bent 1 Check for damage especially to the rear connector of CAUTION Handle the modules carefully and avoid damaging the module the connector pins Do not install if any pins appear to be bent 2 With the latch in the open position see Figure 7 slide the module into the enclosure until the latch engages 1 Check for damage especially to the rear connector of automatically the module 2 With the latch in the open position see Figure 9 slide the module into the enclosure until the latch engages automatically 3 Secure the module by manually closing the latch A click should be heard as the module latch engages 3 Secure the module by manually closing the latch A click should be heard as the module latch engages Figure 7 Cooling Module Latch Figure 9 1 0 Module Latch Figure 10 Installing the I O Module 1 Figure 8 Installing the Dual Fan Cooling Module LaCie 12big rack serial Installing the I O Modules Connecting Storage Quick Install Guide page 7 Figure 11 Installing the I O Module 2 9 Connecting Storage System to Host Enclosure 1 Figure 15 Dual Host Dual Connection IMPORTANT Refer to release note for configuration of maximum number of enclosures Figure 13 Single Host Single Connection LaCie 12big rack serial
12. sing the special chassis latch screws Ensure the latch is orien tated as shown in Figure 2 with the spring arm located against its stop On the right hand side this is at the top on the left at the bottom Chassis Slide 4 Assemble the rack brackets to the rack posts as follows _ Figure 2 Securing Chassis Slides to Enclosure see Figure 3 a Position the location pin at the rear of the rail into a rear rack post hole Attach the bracket to the rear rack post using the washers and screws supplied The screws should be left loose b Extend rail to fit between the front and rear rack posts Rear Rack Post c Attach the bracket to the front rack post using the i washers and screws supplied The screws should be left re loose d Tighten the two clamping screws located along the in side of the rear section of the rack bracket see Figure 3 Round Hole Front Rack Post installing into tapped hole rack Figure 3 Securing Brackets to Rack LaCie 12big rack serial Quick Install Guide 5 Mount the enclosure into the rack as follows see Figure 4 a Lift the enclosure and align it with the rack rails b Carefully insert the chassis slides into the rack rails and push fully home c Tighten the rear rack bracket mounting screws d Withdraw enclosure until it reaches the hard stops approx 400mm and tighten the front rack bracket mounting screws e Return the enclosure to the fully
13. will be set for all the above conditions In addition this LED will flash for an 12big rack serial module soft failure 3 The Logical Fault LED will take the state of the highest priority drive bay fault LED RQST IDENT bit set in Enclosure element Power On System Fault Logical Fault Box Identify Contact Us LaCie USA 22985 NW Evergreen Pkwy Hillsboro OR 97124 sales lacie com LaCie France 17 rue Amp re 91349 Massy Cedex sales fr lacie com LaCie Asia HK 25 F Winsan Tower 98 Thomson Road Wanchai Hong Kong sales asia lacie com LaCie Asia Singapore Centennial Tower Level 34 3 Temasek Avenue Singapore 039190 sales asia lacie com LaCie Australia 458 Gardeners Rd Alexandria NSW 2015 sales au lacie com LaCie Belgium Vorstlaan 165 Bld du Souverain 165 1160 Brussels sales benelux lacie com LaCie Canada 235 Dufferin St Toronto Ontario M6K 1Z5 sales ca lacie com LaCie Germany Am Kesselhaus 5 D 79576 Weil Am Rhein sales de lacie com LaCie Italy Milano Business Park Via dei Missaglia 97 20142 Milano sales it lacie com LaCie Japan K K Uruma Kowa Bldg 6F 8 11 37 Akasaka Minato ku Tokyo 107 0052 sales jp lacie com LaCie Netherlands Postbus 134 3480 DC Harmelen sales benelux lacie com LaCie Middle East FZE LIU E6 PO Box 293860 Dubai Airport Free Zone Dubai U A E sales me lacie com LaCie Nordic Sweden Denmark Norway Finland Sveav gen 90 Dir 11
Download Pdf Manuals
Related Search
Related Contents
División Tecnología MANUAL DE APOYO PARA EL USO DE LA Bullard TI Commander™ Thermal Imager User Manual Cover Group B P1 Samsung Blu-ray-spelare BD-F8900N Bruksanvisning Desq 2008 - Motion Alarm Manuel d’installation Trust 100W Compact MultiFunction Notebook Power Adapter PW-2100 UK Ring Main Unit Dunsthaube - Wohnorama Möbel Kuch Copyright © All rights reserved.