Home
Kohler 116347-2 User's Manual
Contents
1. BodySpa stops automatically before 18 minutes BodySpa does not automatically stop after 22 minutes Variable flow valve wiring error Light bulb is burned out Reverse variable flow valve wire connections Replace light bulb Loose or damaged wiring GFCI trips Identify source of fault and correct Identify source of fault and correct Motor overheated and protection device activated Timer mechanism doesn t work Check for restricted air space around pump box motor vent blockage suction harness blockage Correct and allow motor to cool Replace timer board inside pump motor Wiring error Refer to dealer installer Noisy operation Not enough water in footbath basin Pump cavitates Fill basin 3 inches over top of suction cover Refer to dealer installer 116347 2 AA A 25 Kohler Co Kohler WI z ne gt gt Z Z ES Z g z U CUSTOM BODYSPA USER S INFORMATION Your Custom BodySpa is designed to give you an invigorating hydro massage bathing adventure unlike anything you ve experienced before A BOLD LOOK FOR YOUR HOME OUR MISSION Thank you for choosing The Bold Look of Kohler Our mission is to enhance the level of gracious living for with your Custom BodySpa Personal those who are touched by our products and services Hydro Massage System Kohler craftsmanship offers you a rare combi
2. Keypad doesn t work Replace keypad Circuit board doesn t work Replace circuit board inside control box Motor pump assembly doesn t work Replace motor pump assembly Not enough water in footbath basin Fill basin 3 inches over top of suction cover Water flow surges Not enough water in footbath basin Fill basin 3 inches over top of suction cover Suction is blocked Remove obstruction Harness is blocked Remove blockage Motor starts all Body Jets are not functioning Body Jet is blocked Remove blockage Keypad doesn t work Replace keypad Body Jet butterfly valve wiring loose or damaged or butterfly valve is faulty Identify source of fault and correct or replace faulty butterfly valve Not enough water in footbath basin Pump cavitates Fill basin 3 inches over top of suction cover Motor starts Waterfall does not function Waterfall is blocked Remove blockage Keypad doesn t work Replace keypad Waterfall butterfly valve wiring loose damaged butterfly valve doesn t work Identify source of fault and correct or replace faulty butterfly valve Not enough water in footbath basin Pump cavitates Fill basin 3 inches over top of suction cover Water flow increases when W keypad button is pressed decreases when A button is pressed Waterfall light does not work
3. he 116347 2 AA A 16 Kohler Co Kohler WI INSTALL CABLE WITH OUTLET BOX NOTE If the desired keypad location does not permit you to secure the provided outlet box directly to a stud you can route the cable directly through the wall material without using an outlet box Proceed to Install Cable Without Outlet Box to install the keypad without an outlet box Plug the cable into the corresponding jack located on the bottom of the control box Position the supplied outlet box inside the room s Water Free Zone at the chosen control mounting location so the metal plate not shown will be flush with the finished wall or slightly recessed when installed Install the outlet box so the 10 foot cable is within reach of the control box Do not stretch or pull on the cable Install the outlet box 58 to 60 inches up from the subfloor Secure the outlet box to the nearest stud Route the cable from the control box to the outlet box and insert the loose connector into the knockout hole in the outlet box Create a drip loop in the cable NOTE National Electrical Code requires that you permanently separate the high and low voltage cables INSTALL CABLE WITHOUT OUTLET BOX Plug the cable into the corresponding jack of the control box Route the cable directly through the large hole in the center of the metal plate Temporarily tape together the cable and the metal plate Also tape the two screws to the metal plate to prevent t
4. Tower Serial No Model No SKU K 1001 Pump Kit Serial No TABLE OF CONTENTS FOR YOUR INSTALLATION INSTRUCTIONS HOW TO USE THESE INSTRUCTIONS SERIAL NUMBERS IMPORTANT SAFETY INSTRUCTIONS INSTALLER HAZARD NOTIFICATION FACTORY ASSEMBLED FEATURES PRODUCT MODIFICATIONS CONNECTIONS AND SERVICE ACCESS PRODUCT INSPECTION ELECTRICAL REQUIREMENTS STUD POCKET PREPARATION PLUMBING PREPARATION INSTALL THE TOWER MOUNTING FRAME INSTALL THE PUMP BOX INSTALL VARIABLE FLOW VALVE INSTALL THE SUCTION BRACKET SOLVENT WELD TUBING ELECTRICAL CONNECTIONS 116347 2 AA A HOW TO USE THESE INSTRUCTIONS IMPORTANT It is critical that you follow the installation sequence and details in the steps that follow to successfully install and operate your Custom BodySpa A series of color coded Check Point boxes are included to assist you You need to complete the steps and requirements listed at each Check Point before you proceed to the next series of installation steps This will prevent costly repairs and rework due to unfamiliarity with custom bath and shower installations If necessary consult with a proven expert in custom installations before attempting this installation Kohler Co shall not be responsible for leakage that occurs as a result of inadequate or poor assembly or installation techniques INSTALL CABLE OUTLET BOX INSTALL CABLE INSTALL WATERPROOFING MEMBRANE 18 INSTALL SUCTION BUSHING INSTALL CEMENT BOARD CONSTRU
5. accessibility and so the pump inlet faces in the direction of your planned suction line The pump box must be within 36 inches to either side of the tower so the tower and Waterfall cables will reach to the pump box Do not secure the pump box in place at this time 116347 2 AA A 13 Kohler Co Kohler WI z U z p OC O UCL C 116347 2 AA A INSTALL THE VARIABLE FLOW VALVE ASSEMBLY NOTE Do not use flexible tubing for this tubing section and do not add additional elbows or fittings between the variable flow valve and the pump elbow and union assembly If water does not completely drain from the tower and variable flow valve assembly the resulting air pocket will prevent the pump from priming and the BodySpa will not work Loosely hand tighten the mounting frame union nut to the variable flow valve assembly so the elbow faces toward the pump outlet Loosely hand tighten the pump elbow and union assembly to the pump outlet so it faces toward the variable flow valve assembly Measure and cut a length of 1 1 4 inch I D rigid PVC tubing to connect the variable flow valve to the pump outlet Do not solvent weld the PVC connections at this time Use a level and measuring tape to ensure a minimum 1 4 inch per foot pitch toward the pump CAUTION Risk of personal injury The red and black wire leads must be connected exactly as instructed to prevent the variable flow valve from operatin
6. cut out area around the mounting frame Mark the cement board for the suction fitting hole by first measuring up at least 2 1 2 inches from the footbath basin material Add the thickness of the finished floor material you plan to use and draw a pencil mark at that location Make sure the wall is perfectly flat and smooth within a 5 inch diameter area around the suction hole pencil mark Use a hole saw to drill a 3 1 4 inch hole in the cement board at the pencil mark Carefully cut holes for the water supplies suction drain and drain overflow as well as any lighting fixtures or other required accessories Cut a hole around the keypad outlet box if used If you are not using the outlet box cut or drill a 1 1 8 inch diameter hole for the cable CONSTRUCT FOOTBATH BASIN Construct the footbath basin according to your specific BodySpa room design Employ established shower basin fabrication materials and techniques Provide a 1 4 to 1 2 inch per foot pitch to the footbath basin floor for the correct floor drainage Locate and cut the drain and drain overflow holes according to the instructions packed with the drain The K 7179 Drain has been specially designed for the Custom BodySpa and is recommended for use with this installation The installation instructions included with the K 7179 Drain provide detailed instructions for this installation Install the drain flange according to the drain instructions INSTALL WATER RESISTA
7. leaks Turn off the BodySpa Open the tower and inspect all piping connections for leaks Check the connections on the back surface of the face wall and check all wall and floor joints for leaks Close the tower Thread in and securely wrench tighten two 3 8 inch bolts Do not overtighten CLEAN UP AFTER INSTALLATION Clean the Custom BodySpa room with a mild non abrasive detergent and warm water Do not use abrasive cleansers Remove stubborn stains and paint from the tower surfaces with turpentine or paint thinner Remove dried plaster by carefully scraping with a dull edged piece of wood Do not use metal scrapers wire brushes or other metal tools Remove residual plaster by applying a powder type detergent to a clean damp towel to provide mild abrasive action z U Z p Check Point 10 Ensure that all connections are securely tight Fill the footbath basin with water to 3 inches over the top of the suction cover Run the bodyspa turn off and drain the water check for leakage Open the tower inspect for leakage and close and secure the tower 116347 2 AA A 24 Kohler Co Kohler WI TROUBLESHOOTING SYMPTOMS PROBABLE CAUSES CORRECTIVE ACTION BodySpa does not start stop No power to pump receptacle keypad Set Reset GFCI breaker check wiring Harness is blocked Remove blockage Keypad disconnected from pump control box Reconnect keypad
8. must be 1 1 2 inch I D rigid PVC tubing The K 7179 Drain overflow assembly is designed for a finished wall thickness between 3 4 and 1 3 4 inches and for a maximum finished basin thickness of 1 1 2 inches at the drain o Z o U The drain should not be located more than 48 inches from the drain tee Refer to the roughing in information included with the K 7179 Drain for specific details NOTE The K 7179 Drain is packed with its own installation instructions Please refer to that document to install the drain You can use a floor drain other than the K 7179 if you wish Any floor drain used for this installation must drain water at a minimum rate of 10 gallons per minute to minimize drainage time and must use 1 1 2 inch 1 D drain tubing Be sure to follow the drain manufacturer s instructions WATERPROOFING MATERIAL A WARNING Risk of property damage and concealed leakage To achieve a watertight BodySpa installation it is critical that you install a waterproofing membrane or applied compound according to the material manufacturer s instructions Kohler Co will not be liable for damage caused by waterproofing materials that are improperly installed or sealed The Custom BodySpa produces water flow rates up to amp 0 gallons per minute To achieve a watertight installation it is critical that you install a waterproofing membrane or applied compound to the entire floor and wall su
9. of personal injury To reduce the risk of injury do not permit children to use this unit unless they are closely supervised at all times M DANGER Risk of personal injury Hot whirlpool baths can put certain stresses on the body as does any hot bath shower sauna or steam bath Prolonged immersions in hot water may induce hyperthermia Symptoms of hyperthermia include an increase in the internal body temperature dizziness lethargy drowsiness and fainting The effects of hyperthermia include 1 failure to perceive heat 2 failure to recognize the need to exit the bath 3 unawareness of impending hazard 4 fetal damage in pregnant women 5 physical inability to exit the bath and 6 unconsciousness resulting in the danger of drowning Warning The use of alcohol drugs or other medication can greatly increase the risk of fatal hyperthermia Use this unit only for its intended use as described in this manual Do not use attachments not recommended by Kohler Co Do not operate this unit without the guard cover on the suction fitting Never drop or insert any object into any opening IMPORTANT Flush your Custom BodySpa system twice a month or more depending upon usage as described on Page 29 Keep small objects such as bath toys and bathing accessories out of the BodySpa room while the BodySpa is running Repeated use of personal care products containing oils can damage plastic BodySpa components Do no
10. CT FOOTBATH BASIN INSTALL WALL MATERIAL INSTALL FINISHED MATERIAL INSTALL SUCTION ASSEMBLY INSTALL FAUCET TRIM SPOUT DRAIN INSTALL DOOR ENCLOSURE INSTALL THE TOWER INSTALL THE KEYPAD WATER TEST THE SYSTEM CLEAN UP AFTER INSTALLATION TROUBLESHOOTING 10 Kohler Co Kohler WI IMPORTANT SAFETY INSTRUCTIONS MN WARNING When using electrical products always follow basic precautions including the following MN DANGER Risk of electrical shock Connect only to a circuit protected by a Ground Fault Circuit Interrupter GFCI A pressure wire connector is provided on the exterior of the pump or control within this unit to permit connection of a bonding conductor between this unit and all other exposed metal in the vicinity as needed to comply with local requirements INSTALLER HAZARD NOTIFICATION M WARNING Risk of electrical shock A licensed electrician should make all electrical connections MN WARNING Risk of electrical shock Disconnect power before servicing WARNING Risk of injury or property A damage Please read all instructions thoroughly before beginning installation including the following requirements NOTICE Follow all local plumbing and electrical codes PRODUCT MODIFICATIONS WARNING Unauthorized modification A may cause unsafe operation and poor performance of the Custom BodySpa Do not remove the pump from the pump box or make non recommended modifications to the BodySpa system U
11. CUSTOM BODYSPA DESIGN GUIDE The Custom BodySpa has been engineered to give you ultimate flexibility in creative room design This manual is divided into three main sections Design Guide Installation and User s Guide Use the Design Guide to plan your installation the Installation section for actual construction and assembly and the User s Guide to safely enjoy the benefits of your Custom BodySpa This Custom BodySpa operates at flow rates up to 80 gallons per minute To achieve a watertight installation it is critical that you follow all the design and installation instructions carefully Pay particular attention to leveling and sealing details to obtain a satisfactory installation A WATERPROOFING MEMBRANE OR COMPOUND MUST BE INSTALLED TO THE ENTIRE FLOOR AND WALL SURFACES WITHIN THE CUSTOM BODYSPA ROOM THE CUSTOM BODYSPA IS INTENDED FOR INDOOR USE ONLY o Z o U You will need to incorporate some basic design features into your Custom BodySpa room plans Please study all design parameters carefully and incorporate them into the project layout If necessary consult with a proven expert in custom shower installations before attempting this project Kohler Co shall not be responsible for leakage that occurs as a result of inadequate or poor assembly and installation techniques TABLE OF CONTENTS FOR YOUR DESIGN GUIDE THE TOWER AND SYSTEM PROVIDE ACCESS ROOM SIZ
12. E WATER FREE ZONE PUMP BOX WIRING CONNECTIONS SUCTION ASSEMBLY DRAIN LOCATION WATERPROOFING MATERIAL CEMENT BOARD WATER RESISTANT WALL MATERIAL FINISHED WALL MATERIAL KEYPAD CONTROL LOCATION FOOTBATH BASIN PRIMARY HEAT SOURCE AUXILIARY HEAT SOURCE FAUCETS AND FITTINGS PROJECT REQUIREMENT SUMMARY 116347 2 AA A 2 Kohler Co Kohler WI THE TOWER AND SYSTEM Your Kohler Custom BodySpa is designed to stimulate invigorate and energize your body for total hydro massage relaxation The Custom BodySpa tower features 10 BodySpa jets in five paired arrays and a lighted overhead Waterfall to personalize your BodySpa experience With the BodySpa tower you have complete freedom of movement and choice to focus your hydro massage where you need it the most The Custom BodySpa system features an easy to read electronic keypad control With the keypad you can individualize each BodySpa adventure by selecting the lighted overhead Waterfall or any combination of five pairs of BodySpa jets You can vary the intensity of your BodySpa hydro massage from gentle to vigorous with the touch of a finger S y p Z p C The quiet but powerful 2 horsepower pump and motor propel and recirculate the hydro massaging water up to two times each minute An integral heater helps maintain the temperature of the water as long as the Custom BodySpa is running 210 PROVIDE SUFFICIENT ACCESS You must provide sufficient access t
13. NT WALL MATERIAL Install water resistant wall material to the entire ceiling surface according to established methods z gt gt _ Z Check Point 7 Waterproofing membrane or compound installed Suction bushing installed Cement board installed to subfloor and walls Required holes marked and cut in cement board Confirm footbath basin floor pitch of 1 4 to 1 2 inch per foot 116347 2 AA A 19 Kohler Co Kohler WI Z P Z p INSTALL SUCTION ASSEMBLY Apply a thin bead of clear high quality silicone sealant around the flange rim and on the threads and insert the flange into the bushing Securely thread the flange to the bushing Remove any excess sealant 116347 2 AA A 20 CONSTRUCT FINISHED BASIN WALLS AND CEILING NOTE Refer to the Design Guide section of this manual for finished basin and wall material recommendations and information Install the finished basin walls and ceiling materials according to established installation methods For the suction assembly and K 7179 Drain the wall must be 3 4 to 1 3 4 inches thick The total thickness of the basin basin material and finished floor material combined must not exceed 1 1 4 inches at the drain for the K 7179 Drain Refer to the installation instructions packed with the drain for specific details Cut or drill holes for the tower keypad water supplies suction drain and drain overflow as w
14. R SUCTION HEIGHT FROM FINISHED FLOOR 2 1 2 INCHES TO CENTER 3 1 2 INCHES TO CENTER SUCTION COVER DIAMETER 4 1 4 INCHES DISTANCE FROM PUMP BOX TO TOWER NONE 36 INCHES DUE TO CABLE LENGTH DISTANCE FROM SUCTION TO PUMP BOX NONE 48 INCHES TO PERMIT DRAINAGE AIR SPACE AROUND PUMP BOX 32 CU FT NONE FINISHED WALL THICKNESS 3 4 INCH 1 3 8 INCHES FINISHED FLOOR THICKNESS 1 2 INCH 1 1 2 INCHES PVC PIPE AND BASIN FLOOR PITCH 1 4 INCH PER FOOT 1 2 INCH PER FOOT 116347 2 AA A 9 Kohler Co Kohler WI z U Z p CUSTOM BODYSPA INSTALLATION INSTRUCTIONS All information in this manual is based upon the latest product information available at the time of publication At Kohler we constantly strive to improve the quality of our products we therefore reserve the right to make changes in product characteristics packaging or availability at any time without notice THE CUSTOM BODYSPA IS INTENDED FOR INDOOR USE ONLY IMPORTANT READ THIS BEFORE YOU BEGIN This Custom BodySpa operates at flow rates up to 80 gallons per minute To achieve a watertight installation it is critical that you follow all the design and installation instructions carefully Pay particular attention to leveling and sealing details to obtain a satisfactory installation A WATERPROOFING MEMBRANE OR APPLIED COMPOUND MUST BE INSTALLED TO THE ENTIRE FLOOR AND WALL SURFACES WITHIN THE CUSTOM BODYSPA ROOM SERIAL NUMBERS Model No SKU K 1000
15. TALL THE DOOR ENCLOSURE Install the door enclosure according to the manufacturer s instructions Follow all sealing and installation instructions carefully to ensure troublefree door operation and to limit moisture and heat escape from around the door z gt gt _ Z 116347 2 AA A 21 Kohler Co Kohler WI INSTALL THE TOWER Locate the pin at the bottom left corner of the tower Insert this pin into the bottom left corner hole in the mounting frame bracket Now line up the hole at the top left corner of the tower with the slotted hole in the mounting frame and thread a 3 8 inch bolt through the mounting frame and into the tower Securely wrench tighten the bolt Route the tower cable through the large hole in the mounting frame Snap the tower cable modular plug into the corresponding jack of the control box Install the large strain relief bushing over the tower cable and insert it into the large mounting frame hole NOTE National Electrical Code requires that you permanently separate the high and low voltage cables Route the waterfall light wires through the small hole in the back of the mounting frame Connect the waterfall light wire connectors to the transformer terminals white to white black to black Install the small strain relief bushing over the waterfall light wires and insert it into the small mounting frame hole Securely handtighten the tower union nut to the mounting frame u
16. all framing Locate the false wall parallel with the face wall Plan to install the pump box underneath the tower to maximize accessibility and so the pump inlet faces in the direction of your planned suction line The pump box should be within 36 inches to either side of the tower to ensure that the tower and Waterfall cables reach to the pump box Plan the false wall so at least 12 inches of access space exists to the back of the face wall If you plan the installation for an existing home or if several different access panels along the back wall are not feasible provide more than 14 inches of access space between the false wall and face wall so a repair person can maneuver between the walls 116347 2 AA A 4 Kohler Co Kohler WI WIRING CONNECTIONS WARNING Risk of electrical shock To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle protected by a Ground Fault Circuit Interrupter GFCI Do not remove the plug s grounding pin Do not use a grounding adapter The Kohler Custom BodySpa is equipped with a cord and plug All wiring of the pump has been completed at the factory A licensed electrician will need to install a GFCI protected 120 V 20 A erounded outlet The electrician must install the outlet behind the BodySpa and within 24 inches of the pump No other load should be on this circuit S UD G Z G SUCTION ASSEMBLY The purpose
17. ant to the cover plate sealant grooves as shown Slip the center pin at the top of the cover plate up through the hole in the keypad Secure the cover plate to the keypad with a panhead screw Select the bottom cap it contains a small pinhole and has a small notched area along the contact surface edge IMPORTANT Apply clear silicone sealant to the back surface of the bottom cap and also to the edge that contacts the cover plate Align the bottom cap holes with the cover plate pins and push the cap into place Repeat for the top cap NOILLV TIVLSNI Remove any excess sealant Check Point 9 Faucet trim and spout installed Drain assembly installed Footbath basin filled with water and checked for leakage Door enclosure installed Tower installed Keypad installed and sealed with silicone sealant E E E E a E E Keypad wiring connections made 116347 2 AA A 23 Kohler Co Kohler WI WATER TEST THE SYSTEM Allow the silicone sealant and any finished wall materials or grout to fully cure before proceeding Follow all manufacturer s recommendations regarding water exposure to their products as well as product cure times Make sure all PVC union connections are securely hand tightened and that all union connections use an O ring Fill the footbath basin at least 3 inches above the top of the suction cover Turn on the BodySpa for about five minutes and check all visible connections for
18. arance for servicing the pump and controls The access panel must be located immediately next to the pump box Refer to the Design Guide at the front of this manual and the stud framing preparation requirements on Page 12 ELECTRICAL REQUIREMENTS The installation must have a Class A Ground Fault Circuit Interrupter GFCI The GFCI protects against line to ground shock hazard Use a 120 V 20 A 60 Hz dedicated service for the BodySpa Kohler Co Kohler WI z gt gt Z STUD POCKET PREPARATION NOTE Carefully study the roughing in pages located in the inside back cover pocket and the illustration at right before you begin construction of the stud pocket Follow the framing details carefully Use 2x4 framing for the stud pocket Make sure you allow for access to the pump in the event the BodySpa requires service Determine the drain location We recommend a room size approximately 60 inches long x 48 inches wide x 84 inches high for the Custom BodySpa installation The basin design must provide for a water depth of at least 3 inches above the top of the suction cover This will allow an overall basin depth of about 9 inches The threshold of the basin should be 6 to 7 inches above the top of the suction cover Construct the basin framing to result in an overall basin water capacity between 90 and 200 gallons You must provide at least 32 cubic feet length x width x height of unrestricted air s
19. d consider installing a dedicated 3 water heater for the BodySpa installation alone and Surface Area Sq Ft implement a second water heater for all other hot AG1NO NOSAG Based Upon 9 inch Nominal Water Depth water applications in the residence AUXILIARY HEAT SOURCES Based Upon 9 inch Nominal Water Depth NOTE The Kohler Custom BodySpa employs a heater inside the pump housing to automatically maintain the water temperature at a comfortable level This heater is not intended to replace the primary water heater We recommend a room size approximately 5 feet long x 4 feet wide x 7 feet high for the Custom BodySpa If you design a larger room you should employ an auxiliary heat source such as a steam generator to support the pump heater and help maintain the ambient temperature of the room FAUCETS AND FITTINGS Because the Custom BodySpa recirculates tempered water the user adds this installation requires the addition of a bath and shower faucet to fill the footbath basin and for personal cleansing We recommend either K 1099 Taboret Rite Temp single control fitting or the K 1098 Taboret two handle faucet kit Talk to your distributor for additional information FROSECT SUIS EMEN UMMARY WATER DEPTH 3 INCHES ABOVE TOP OF 4 INCHES ABOVE TOP OF SUCTION COVER SUCTION COVER FOOTBATH BASIN CAPACITY 90 U S GALLONS 200 U S GALLONS THRESHOLD HEIGHT 6 INCHES ABOVE TOP OF 7 INCHES ABOVE TOP OF SUCTION COVER SUCTION COVE
20. depending upon usage 1 Fill the footbath basin with hot water to a level 3 inches above the top of the suction cover BL ae bi s E PTE tT a i EEE EEE Leet l i M f H B i p v hee k r f fi A I J E eats em 2 Add 2 teaspoons low foaming dishwasher detergent and 1 2 cup household bleach to the water 3 Run the BodySpa for 5 to 10 minutes in the Waterfall mode then another 5 to 10 minutes with all ten Body Jets running at the same time Then shut off the BodySpa and drain the water 4 Fill the footbath basin with cold water to a level 3 inches above the top of the suction cover and run the BodySpa for another 5 to 10 minutes in both the Waterfall and ten Body Jet modes Drain the footbath basin and wipe it dry with a clean soft cloth ml M i l af kit T p BAI ha C y ep UD Z Eo z Z 116347 2 AA A 29 Kohler Co Kohler WI Z ES Z g z U CLEANING YOUR CUSTOM BODYSPA TOWER Use mild soap and warm water to clean your Custom BodySpa tower Wipe the entire surface completely dry with a clean soft cloth Many cleaners contain harsh chemicals such as ammonia which can adversely affect the finish and are not recommended for cleaning the tower Do not use abrasive cleansers or solvents on your Kohler Custom BodySpa tower CLEANING THE WALLS AND BASIN Various wall and basin materials require different clea
21. ell as any light fixtures or other accessories DANGER Risk of death or serious injury Gaps between the suction cover and the finished basin material present a serious hair entrapment hazard The finished basin material must be constructed so the suction cover installs against a flat smooth surface Carefully repair or seal all gaps Finish the basin wall surface so it is perfectly flat and smooth within the 5 inch diameter area around the suction hole Install the suction cover and metal spacer if included to the flange with the suction cover screw Use a screwdriver to tighten the suction cover screw until snug Do not overtighten In addition make sure all the suction cover holes are clear and unobstructed to maximize performance Press the plug button in place over the screw head Permanently secure the suction bracket and pump box to the wall and floor if desired Allow the sealant to fully cure Kohler Co Kohler WI INSTALL FAUCET TRIM SPOUT AND DRAIN MN CAUTION Risk of property damage You must adequately seal the valve spout and other plumbing fittings to prevent water leakage behind the finished wall Install the faucet trim and spout according to the manufacturer s instructions Seal around the plumbing fittings with a high quality sealant Install and connect the drain according to the instructions packed with the drain Fill the footbath basin with water and check for leaks INS
22. g in reverse Locate the red and black wire lead cable at the back of the pump Connect the red wire lead to the positive lt gt variable flow valve terminal Then connect the black wire lead to the negative lt gt terminal Check that the wire leads are connected to the correct terminals before proceeding Check Point 3 14 Pump box is positioned within 36 inches of tower mounting frame and is oriented toward suction water intake line Suction bracket assembly removed from pump box if necessary Variable flow valve is oriented toward the pump Rigid 1 1 4 inch i d pve tubing measured cut and fit but not solvent welded Pitch of 1 4 inch per foot from tower mounting frame to pump outlet connection Variable flow valve assembly attached _ Red lead Black lead Kohler Co Kohler WI INSTALL THE SUCTION BRACKET Position the suction bracket assembly in the desired installation location Consider locating the suction assembly on a piece of 2x6 if needed to provide better clearance with the finished basin material The center of the suction cover must be located between 2 1 2 and 3 1 2 inches up from the estimated finished floor surface Do not secure the suction bracket assembly in place at this time NOTE Water drainage of the entire Custom BodySpa system occurs through the suction assembly Do not use flexible tubing for the suction line Use straight sections of rigid PVC tubing and a
23. hem from becoming lost Create a drip loop in the cable to prevent water from following the cable down to the control box a z lt gt Z Temporarily secure the cable and metal plate to the stud nearest your chosen keypad mounting location within the room s Water Free Zone Position the metal plate 58 to 60 inches up from the subfloor Leave the cable and metal plate attached here until the finished wall is constructed At that time you will permanently attach the metal plate flush to the outside surface of the finished wall with two screws Then you will secure the cable to the metal plate with a cable tie looped between the large and small center holes in the metal plate NOTE National Electrical Code requires that you permanently separate the high and low voltage cables 116347 2 AA A 17 Kohler Co Kohler WI Check Point 6 GFCI protected electrical power supplied to pump box 120 V 20 A Keypad cable installed and connected to the control box 1 With outlet box or _ Without outlet box INSTALL WATERPROOFING MEMBRANE OR COMPOUND AN WARNING Risk of property damage and concealed leakage To achieve a watertight BodySpa installation it is critical that you install the waterproofing membrane or applied compound according to the material manufacturer s instructions Kohler Co will not be liable for damage caused by waterproofing materials that are improperly installed o
24. ions and exclusions may not apply to you This warranty gives you specific legal rights You may also have rights which vary from state to state This limited warranty provides specific legal rights as they apply within the USA and other rights may be available but may vary from country to country This is our exclusive written warranty KOHLER CO KOHLER WISCONSIN 53044 Kohler Co Kohler WI THEBOLDIOCK OF KOHLER Publication No 116347 2 AA A 1999 Kohler Co Kohler WI
25. izzy or lightheaded at any time while using your BodySpa immediately step into the Water Free Zone turn off the unit by pressing the Power key and exit the room immediately e Press the Power key a second time to turn off the BodySpa 116347 2 AA A 28 Kohler Co Kohler WI LOOK AT THESE FEATURES e Your Custom BodySpa is designed to stimulate invigorate and energize your body for total hydro massage relaxation e Activate any or all of the Body Jet arrays or the lighted overhead Waterfall to personalize your BodySpa experience e With BodySpa you have complete freedom of movement and choice to focus your hydro massage where you need it the most e BodySpa features an easy to read electronic keypad control With it you can individualize each BodySpa experience by selecting the lighted overhead Waterfall or any combination of five pairs of Body Jets You can vary the intensity of your BodySpa hydro massage from gentle to vigorous with the touch of a finger e The quiet but powerful 2 horsepower pump and motor combine to deliver up to 80 gallons of water each minute to intensify your hydro massage bathing experience e The integral heater built right into the pump housing helps maintain the temperature of the water while your Custom BodySpa is running CARE AND CLEANING OF YOUR CUSTOM BODYSPA FLUSHING YOUR CUSTOM BODYSPA SYSTEM Sanitize your Custom BodySpa system by flushing it twice a month or more
26. loor material The finished floor material must be slip resistant tile or stone to reduce the potential for slipping accidents Bear in mind that various materials offer different heat retaining properties e Desired drain location The drain location should be no more than 48 inches from the drain overflow ell Design the footbath basin so the combined thickness of the subfloor cement board waterproofing material mortar bed and finished material does not exceed 1 1 2 inches at the drain if the K 7179 Drain will be used For the K 7179 Drain the combined basin wall thickness must be between 3 4 and 1 3 4 inches where the drain overflow will be installed e Suction location The center of the suction cover must be located between 2 1 2 and 3 1 2 inches up from the finished floor surface 116347 2 AA A Kohler Co Kohler WI PRIMARY HEAT SOURCE Employ a water heater of sufficient size and efficiency to supply hot water to the Custom BodySpa footbath basin while still able to maintain other hot water needs of the residence Carefully study the chart at left to determine the amount of hot water your installation will require Typically you can expect a 50 50 mix of hot and cold water to fill the footbath basin So a 50 gallon water heater will supply the minimum hot water needs for a 100 gallon capacity basin SUOTTED S11 AjraBdE7j IIB If the footbath basin water capacity is over 80 gallons you shoul
27. n Customer Service Department 444 Highland Drive Kohler WI 53044 USA or by calling 1 800 4 KOHLER Please be sure to provide all pertinent information regarding your claim including a complete description of the problem the product model number color finish and the date the product was purchased Also include the name of your contractor or distributor and your original invoice 116347 2 AA A 30 LIMITED ONE YEAR WARRANTY Kohler plumbing fixtures and fittings are warranted free of manufacturing defects Kohler Co will at its election repair replace or make appropriate adjustment where Kohler Co inspection discloses any such defects occurring in normal usage within one year after installation Kohler Co is not responsible for installation or removal costs To obtain warranty service contact Kohler Co either through your Dealer or Plumbing Contractor or by writing Kohler Co Attn Customer Service Department 444 Highland Drive Kohler WI 53044 USA or by calling 1 800 4 KOHLER from within the USA Implied warranties including that of merchantability or fitness for a particular purpose are expressly limited in duration to the duration of this warranty Kohler Co disclaims any liability for special incidental or consequential damages Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of special incidental or consequential damages so these limitat
28. n listed by Underwriter s Laboratories thus ensuring safety for you and your family Your new BodySpa also conforms to rigid ANSI and IAPMO standards set within the plumbing industry Kohler Co Kohler WI D E Z os Z bo e z Z Z Q Z an Z y an U LET S GET STARTED If you re like most people who install a Kohler Custom BodySpa you can t wait to get in and try it out You ll soon find that the BodySpa features and controls are very easy to use and offer you a safe and exciting personal care adventure There are a few things you should know before you start using your new Custom BodySpa Please spend a few minutes with these simple rules and then you ll be ready to go e Remove all loose bathing items such as soap bars shampoo bottles and washcloths from the BodySpa room Make sure nothing is resting on the Waterfall ledge e Remove your eyeglasses or contact lenses and any loose jewelry before entering the BodySpa room e Don t use shampoo soap or bubble bath in the BodySpa water Of course you can freely use shampoo and soap for showering before you fill the footbath basin e Use the bath fill spout to fill the footbath basin with tempered water to a level at least 3 inches above the top of the suction cover e Close the door enclosure securely e Always stand clear of the water stream when you turn on the BodySpa or whenever you use the keypad control to adj
29. nation of proven performance and graceful sophistication with the Custom BodySpa The dependability and beauty of your BodySpa will surpass your highest expectations We re very proud of the Custom BodySpa here at Kohler Co and you will be too Please take a few minutes to study this operating and maintenance guide before you use the BodySpa for the first time Pay special attention to the care and cleaning instructions starting on Page 29 All information in this guide is based upon the latest product information available at the time of publication At Kohler we constantly strive to improve the quality of our products and therefore reserve the right to make changes in product characteristics packaging or availability at any time without notice TABLE OF CONTENTS FOR YOUR USER S INFORMATION A BOLD LOOK FOR YOUR HOME OUR MISSION IMPORTANT SAFETY INSTRUCTIONS LET S GET STARTED LOOK AT THESE FEATURES CARE AND CLEANING FLUSHING YOUR BODYSPA SYSTEM CLEANING YOUR BODYSPA TOWER CLEANING THE WALLS AND BASIN CLEANING YOUR DOOR ENCLOSURE SERVICE AND WARRANTY CALL US FOR HELP LIMITED ONE YEAR WARRANTY 116347 2 AA A 26 Kohler Co Kohler WI IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS A WARNING When using this unit always follow basic precautions including the following MN DANGER Risk
30. nauthorized modifications could adversely affect the performance and safe operation of the unit Kohler Co shall not be liable under its warranty or otherwise for personal injury or damage caused by any unauthorized modification PRODUCT INSPECTION Carefully unpack and inspect the tower pump box and suction bracket for damage Return all materials to the cartons during construction to prevent damage 116347 2 AA A 11 To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle protected by a Ground Fault Circuit Interrupter GFCI Do not remove the plug s ground pin Do not use a grounding adapter Install to permit access for servicing Grounding is required The unit should be installed and grounded by a qualified service representative FACTORY ASSEMBLED FEATURES Factory installed components include a tower with ten pre assembled BodySpa jets and a waterfall a pump with integral heater and a control The pump and most PVC piping connections are factory assembled The pump kit consists of components that require assembly installation and sealing on the job site by a reliable qualified plumber CONNECTIONS AND SERVICE ACCESS Before installation ensure proper access to the final connections Install to permit access for servicing NOTICE Provide unrestricted service access to the pump box An access panel must be constructed to allow for sufficient cle
31. ners and cleaning methods to keep them looking like new Follow the care cleaning and maintenance instructions furnished by the wall and basin material suppliers and manufacturers CLEANING YOUR DOOR ENCLOSURE For Kohler Door Enclosures Keep your Kohler door enclosure looking like new with a simple routine of daily care Apply a glass cleaner with a clean sponge and immediately rinse off the area with clean water Water conditions in various parts of the country will determine any extra cleaning attention you may need to give your door enclosure Kohler Co does not recommend the use of harsh abrasive chemicals on any of its products Harsh cleansers will damage the metal and glass finish on your door enclosure We recommend that you replace seals when they show signs of wear yellowing or leakage For replacement parts please contact the dealer where you purchased the door enclosure For non Kohler Door Enclosures Follow the care and cleaning instructions furnished by the door enclosure manufacturer SERVICE AND WARRANTY INFORMATION CALL US FOR HELP 1 800 4 KOHLER Contact your dealer or plumbing contractor if you encounter problems with your Custom BodySpa Ask them to review this booklet to be sure all the design and installation steps have been followed exactly If the BodySpa system still fails to operate correctly contact Kohler Co either through your dealer or plumbing contractor or by writing Kohler Co Att
32. nion Be sure the union O ring is in place Carefully pivot the tower closed Line up the holes at the top and bottom right corners of the tower with the slotted holes in the mounting frame Thread a 3 8 inch bolt through the mounting frame and into the tower at the top and bottom Tighten the bolts securely but do not overtighten z a U Z p You will water test and inspect the tower and mounting frame later so you may want to only install and handtighten one of the required bolts at this time Both bolts will need to be securely tightened later 116347 2 AA A 22 Kohler Co Kohler WI INSTALL THE KEYPAD MA CAUTION Risk of personal injury or product damage The metal plate must be installed flush with the finished wall or slightly recessed maximum 1 4 inch Feed the cable through the hole in the metal plate Use two flathead screws to attach the metal plate to the outlet box or finished wall material so the metal plate is flush with the finished wall or slightly recessed maximum 1 4 inch Snap the keypad modular plug into the keypad cable jack Apply silicone sealant to each of the keypad screw holes and around the keypad edges and secure the keypad to the metal plate with four panhead screws AN CAUTION Risk of personal injury or product damage Prevent water damage to the keypad by applying silicone sealant as instructed IMPORTANT Apply a continuous bead of clear silicone seal
33. o the pump box and controls drain connections suction housing water supplies and any lighting fixtures or other accessories The false wall discussed on Page 4 may provide adequate access to all necessary components ROOM SIZE We recommend a room size approximately 60 inches long x 48 inches wide x 84 inches high for the Custom BodySpa installation The basin design must provide for a water depth of at least 9 inches measured along the basin wall Construct the basin 5 3 framing to result in an overall basin water capacity Surface Area Sq Ft between 90 and 200 U S gallons study the chart at left A room size of at least 47 x 50 inches will be large enough to promote freedom of movement o P while using the Custom BodySpa yet small enough to contain the comforting heat and moisture produced by the system suoje S Ajrd8de7j TIE Based Upon 9 inch Nominal Water Depth A smaller sized room may not support the required Water Free Zone area for the user to move clear of the powerful water stream If you design the room much larger than 60 x 48 inches you need to consider adding an auxiliary heat source to compliment the integral pump heater This auxiliary heat source could be a steam generator Any auxiliary heat must have its own separate electrical service 116347 2 AA A 3 Kohler Co Kohler WI WATER FREE ZONE You must design a Water Free Zone area into the room layout The Water Free Zone offer
34. of the suction bracket is to position the suction housing at the correct installation height and to provide the installer with a means of securing the suction housing in place during final assembly Do not remove the suction fitting from the bracket assembly You can locate the suction along any wall of the Custom BodySpa room within 48 inches of the pump box as long as the overall wall thickness will not exceed 1 3 4 inches Plan to provide access to the suction assembly in case servicing is needed The suction location must allow the installer to route straight lengths of 1 1 2 inch I D rigid PVC tubing with no vertical elbows inline to trap water from the suction housing to the pump inlet You can use a 90 degree elbow at a wall corner if the suction is located on a different wall than the pump box NOTE Refer to the minimum waterline height information on the side of the pump box to determine the maximum pump box height needed for the pump to prime effectively Plan to apply a minimum 1 4 inch per foot pitch toward the suction housing to provide adequate water drainage through the suction line 116347 2 AA A 5 Kohler Co Kohler WI DRAIN LOCATION We recommend the K 7179 Drain for this installation The K 7179 Drain has been specially designed for the Custom BodySpa and uses a large capacity strainer and drain tube to reduce drainage time The drain tube section of the K 7179 Drain is provided by the installer and
35. ohler WI o Z o U FOOTBATH BASIN Design a mortar bed footbath basin using typical shower basin fabrication methods and materials Carefully study the following factors while designing your Custom BodySpa footbath basin e Basin size and shape We recommend a room size approximately 60 inches long x 48 inches wide x 84 inches high for the Custom BodySpa installation The basin design must provide for a water depth of at least 3 inches above the top of the suction cover The threshold of the basin should be 6 to 7 inches above the top of the suction cover Next locate the drain overflow so it will produce a minimum water depth 3 inches above the top of the suction cover Design the basin framing to provide an overall basin water capacity between 90 and 200 gallons Study the Surface Area chart on Page NO TAG The size of the basin will affect the amount of hot water needed each time the user fills the Custom BodySpa footbath basin Ledges seats shelves and steps are all excellent ideas to enhance the character and functionality of the Custom BodySpa installation but remember that these things may also slow down the return of water to the basin This in turn may demand that the user add more water to fill the footbath basin before use e Floor pitch Incorporate a finished floor pitch of 1 4 to 1 2 inch per foot toward the drain to provide a safe efficient water drainage surface e Finished f
36. pace around the pump box for the motor to cool properly and to provide access to the pump We suggest you construct a false wall behind the face wall framing Locate the false wall along the tower wall For new installations build this false wall so at least 12 inches of access space exists to the back of the face wall For existing installations with finished walls or if separate access panels for the pump drain water supplies and suction assembly are not feasible provide more than 14 inches of access space between the false and face walls soa repair person can maneuver between the walls z E U z p Carefully study the door enclosure installation instructions packed with the door enclosure Construct suitable framing for the door enclosure including a header and support framing above the doorway to prevent heat and moisture from escaping Remember to locate the door enclosure perpendicular to the tower wall If you plan to install grab bars or other accessories provide sufficient backing Check Point 1 Room size and layout known Provide 32 cu ft air space around pump box Footbath basin size and shape known Face and false wall locations known Drain location known 116347 2 AA A 12 Kohler Co Kohler WI PLUMBING PREPARATION NOTE Locate the drain overflow so the PVC drain pipe will not exceed 48 inches in length F Position the plumbing supplies and drain trap according to the
37. r sealed NOTE The waterproofing membrane or applied compound and the cement board can be installed in any order you prefer as long as they are installed exactly as directed Follow all material manufacturer s instructions Install a waterproofing membrane or applied compound to the entire floor and wall surfaces up to the ceiling Although some membranes can be installed directly to the stud framing we suggest you install a plywood backing behind the membrane at least to the height of the basin threshold z a U Z p INSTALL SUCTION BUSHING Use a 3 1 4 inch hole saw to carefully cut a hole in the waterproofing membrane and plywood backing at the suction inlet location Press the spacer fully into the suction housing inlet Apply silicone sealant to the bushing flange surface and insert the bushing through the suction hole Partially thread the nut to the bushing Do not tighten Apply silicone sealant to the end threads of the bushing and carefully thread the bushing to the housing until hand tight Wrench tighten an additional 1 4 turn Do not overtighten Wrench tighten the nut against the plywood backing Do not overtighten Remove any excess sealant 116347 2 AA A 18 Kohler Co Kohler WI INSTALL CEMENT BOARD Install cement board to the walls according to established installation methods The cement board must cover the entire wall surface from ceiling to subfloor Provide a
38. rfaces up to the ceiling You must follow the material manufacturer s instructions to ensure a watertight installation 116347 2 AA A 6 Kohler Co Kohler WI CEMENT BOARD The Custom BodySpa room design must utilize cement board over the entire wall surface from ceiling to subfloor WATER RESISTANT WALL MATERIAL You should plan to install water resistant wall material on the entire ceiling surface E y p Z p C m FINISHED WALL MATERIAL You can use any waterproof material to finish the walls and ceiling of your Custom BodySpa room including ceramic and glass tile stone and solid surface material Keep in mind that various materials have different heat retaining properties KEYPAD CONTROL LOCATION Consider three factors when you choose a location for the keypad control The keypad control must be e within the Water Free Zone User safety and comfort dictate that the keypad control be installed and operated within the room s Water Free Zone because of the volume and force of the BodySpa water e at the recommended height We recommend that the keypad control be located between 58 and 60 inches up from the floor of the footbath basin to maximize usability and user comfort e within reach of the control box The keypad control uses a 10 foot cable which cannot be spliced extended or stretched Choose the keypad control location accordingly 116347 2 AA A 7 Kohler Co K
39. roughing in dimensions and the Custom BodySpa room design Cap the supplies and check for leaks INSTALL THE TOWER MOUNTING FRAME On one of the tower mounting studs draw a pencil line exactly 18 5 8 inches up from the subfloor You will use this mark to temporarily position the tower mounting frame at the correct height Be precise with this measurement Remove the three 3 8 inch tower bolts from the locations shown and carefully lift the tower out of the mounting frame Carefully set the tower aside where it will not be damaged Position and level the mounting frame between the tower mounting studs and line up the bottom metal edge with the pencil line you drew on one of the studs Loosely hold the mounting frame to the stud framing with four of the ten drywall screws provided Do not turn the screws all the way in at this time Check Point 2 Plumbing supplies installed and capped Tower mounting frame bottom edge positioned 18 5 8 inches above the subfloor Tower mounting frame loosely mounted to studs z lt gt Z INSTALL THE PUMP BOX The pump box contains a 2 horsepower pump and motor along with the control box and an integral heater Remove the suction bracket assembly from the pump box The suction bracket can later be installed in any chosen location within 48 inches of the pump box Fit the pump box between the false wall and face wall Locate the pump box to maximize
40. s three important safety and comfort benefits that should give it the highest priority in your design plans e Keypad control access User safety and comfort dictate that the keypad control be installed and operated in the room s Water Free Zone because of the volume and force of the BodySpa water e Door enclosure location The Water Free Zone offers a perfect location for the user to enter and exit the Custom BodySpa room unimpeded by the forceful waters of the hydro massage The door enclosure must be installed to a side wall away from the main force of the water to prevent water leakage past the door seals Kohler Co offers several door enclosure designs that are suitable for use with the Custom BodySpa We recommend a pivot door enclosure from Kohler s Focal or Arica lines o Z o U e Water Free Zone relief It is important for the Custom BodySpa room to have an area where the user can quickly and easily step out of the water stream for a few moments if desired PUMP BOX NOTE Do not remove the pump from the pump box The pump box contains a 2 horsepower pump and motor along with a control box and an integral heater You must provide at least 32 cubic feet length x width x height of unrestricted air space around the pump box to allow the motor to cool properly and to provide accessibility to the pump and control box We suggest you construct a false wall behind the tower face w
41. t most one additional elbow or fitting if needed Always maintain a minimum 1 4 inch per foot pitch toward the suction assembly when measuring and connecting the piping Do not use elbows to change the vertical direction of the tubing Measure and cut a length of 1 1 2 inch I D rigid PVC tubing to connect the suction housing to the pump inlet Do not solvent weld the PVC connections at this time Use a level and measuring tape to ensure a minimum 1 4 inch per foot pitch toward the suction fitting to provide adequate drainage NOTE Refer to the minimum waterline height information on the side of the pump box to determine the maximum pump box height If the suction line does not provide the necessary 1 4 inch per foot pitch shim under the pump box to raise the pump box slightly to achieve the correct pitch Then remove the four drywall screws from the mounting frame and raise the mounting frame the same distance you raised the pump box Re install the four drywall screws and tighten securely NOTE If you raise the pump box and tower height you must also plan to increase the footbath basin minimum water level accordingly This will increase the threshold height and minimum 9 inch water depth Failure to do so will prevent the pump from priming Install the remaining six drywall screws to the mounting frame and tighten securely Check Point 4 Suction bracket assembly is positioned Rigid 1 1 2 inch i d pve tubing meas
42. t use heavy vegetable based shampoos or bath oils BodySpa hydro massage action can cause even a small amount of bubble bath bath soap shampoo or bath oil to foam excessively For this reason refrain from using these products during BodySpa operation 116347 2 AA A 27 Do not allow the water temperature in the BodySpa to exceed 104 F 40 C The unit must be connected only to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner there is a ground current flowing indicating the possibility of an electric shock DO NOT use this unit Disconnect the unit and have the problem corrected by a qualified service representative before using To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle protected by a Ground Fault Circuit Interrupter GFCI Do not remove the plug s ground pin Do not use a grounding adapter A pressure wire connector is provided on the exterior of the pump or control within this unit to permit connection of a bonding conductor between this unit and all other exposed metal in the vicinity as needed to comply with local requirements Your new Kohler Custom BodySpa has bee
43. ured cut and fit but not solvent welded Waterline height confirmed using the label on the pump box Minimum pitch of 1 4 inch per foot from pump inlet connection to suction housing Tower mounting frame is permanently secured 116347 2 AA A 15 Kohler Co Kohler WI z lt gt Z SOLVENT WELD TUBING Solvent weld the PVC tubing connections using care to maintain the established drainage pitch in the lines Make sure each union connection includes the reguired O ring Securely hand tighten the union nuts Check Point 5 Confirm that all previous check point requirements have been met Solvent weld all pve tubing joints and hand tighten the union nuts with the O rings in place MAKE ELECTRICAL CONNECTIONS WARNING Risk of electrical shock To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle protected by a Ground Fault Circuit Interrupter GFCI Do not remove the plug s grounding pin Do not use a grounding adapter A iii Sa z s U z p J The Kohler Custom BodySpa is equipped with a cord and plug All wiring of the pump has been completed at the factory A licensed electrician must install a GFCI protected 120 V 20 A grounded outlet Locate the outlet behind the BodySpa and within 24 inches of the pump Plug the BodySpa into this outlet No other load should be on this circuit i
44. ust the water flow You should also step into the Water Free Zone anytime you want to take a short break from the invigorating effects of your hydro massage experience e Use your hand to check the water temperature in the footbath basin before you start up your Custom BodySpa Never fill the footbath with water that is too hot in excess of 104 F e Press the Power key to turn on the BodySpa e When you turn on the BodySpa it will take several seconds for the water to begin flowing Let the water flow for several seconds before you enter the water stream so the water temperature has a chance to moderate e When you turn on the BodySpa the water will start to flow at its lowest setting We suggest you increase the water force gradually until you get used to the intensity of the BodySpa experience Press the amp or W key on the keypad control to increase or decrease the water flow e The Waterfall will automatically start when you turn on the BodySpa When you press the Body Jets key water will begin flowing from Body Jet arrays 2 3 and 4 at low speed The Waterfall will turn off Toggle any of the number keys to turn on or off the corresponding Body Jet arrays e The BodySpa will automatically shut off after about 20 minutes of continuous use If you want to use your BodySpa for more than one 20 minute cycle simply step into the Water Free Zone and restart the action by pressing the Power key e Ifyou feel faint d
Download Pdf Manuals
Related Search
Related Contents
d-COLOR - Olivetti Bedienungsanleitung Philips MCD710 User's Manual Copyright © All rights reserved.