Kidde KN-COPE-D Brochure
Contents
1. A Kidde lt United Technologies Battery Operated Combination Carbon Monoxide amp Photoelectric Smoke Alarm Alarm Voice message warning system Front loading battery Part Number CP9000 Model KN COPE D Warns of hazard by announcing Fire Fire or Warning Carbon Monoxide Alerts user when the unit has detected CO concentrations of 100ppm or higher e Red Alarm mode e Green Indicates power is present Silences the unit during nuisance alarm situations Smoke must be present before hush is activated Description Features and Benefits The Kidde Front Loading Smoke and Carbon Monoxide alarm part e Front Loading Battery Speeds up replacement by eliminating the CP9000 offers protection from two hazards fire and CO in need to remove the unit from the ceiling or wall one unit This 9 volt battey powered alarm emits a beeping tone e Unique Battery Door Design Will not close if battery is not followed by a voice warning that clearly announces the danger by installed properly saying Fire Fire or Warning Carbon Monoxide The uniquely e Voice Warning Supplements warning from the traditional 85 decibel designed front loading battery compartment makes battery replace alarm by clearly stating the danger present fire or carbon monoxide ment quick and easy and ensures proper installation Manufactured e Photoelectric smoke sensor May detect visible fire particles associated wi
2. Weight 7 b Interconnects No Warranty 10 year limited Pack Dimensions Cartons Qty w x d x h inches Weight Pallet Cut Case 4 Units 7 9X 13 2 xX 11 7 1 8 54 1016 Corporate Park Drive Mebane NC 27302 1 800 880 6788 www Kidde com g Kidde Distributed by KL CP9000 sheet rev 04 2014
3. unison with the sounder pattern The unit shall include the Smart Hush feature that silences the unit for approximately 8 minutes if a nuisance alarm condi tion occurs The Green LED on the alarm will flash every 2 seconds while in Smart Hush and will automatically reset itself Smart Hush Feature also provides voice Ordering Information Ordering Pack Number UPC 12 of 5 Config 21010031 0 47871 10031 6 100 47871 10031 6 CLAM annunciation of Hush Mode Activated when Smart Hush is activated and Hush Mode Cancelled when the Hush cycle ends The unit shall also indicate a low battery warning utilizing each of the following methods a brief alarm chirp the voice announcement of Low Battery The unit shall at a minimum meet the requirements of UL 2034 UL217 NFPA72 chapter 11 2002 edition The State of California Fire Marshall NFPA101 One and two family dwellings Federal Housing Authority FHA Housing and Urban Development HUD It shall also include a 10 year manufacturer s limited warranty Claim approved by UL based on manufacturer s reported testing Technical Specifications Part Number CP9000 Model KN COPE D Power Source 9V battery Smoke Sensor Photoelectric CO Sensor Electrochemical Audio Alarm 85dB at 10ft Temperature Range 40 F 4 4 C to 100 F 37 8 C Humidity Range 10 95 relative humidity non condensing Size 5 79 in diameter x 1 85 depth
4. The 6 minutes of reset if 7Oppm or more of CO is present red LED light will flash This pattern will continue every minute for Silences end of life chirp for two days at a time up to 30 days maximum every minute accompanied by the chirp sound The LOW BATTERY door will lock to deter theft or tampering warning will only sound once every fifteen minutes This cycle will e Green LED Will flash every 30 seconds to indicate proper operation conunug for at least 7 days e Red LED Flashes in conjunction with the alarm sounding Voice Hush Indication HUSH MODE ACTIVATED and HUSH e End of Life Signal Ten years after initial power the unit will chiro twice MODE CANCELLED voice announcement every 30 seconds to indicate the need to immediately replace the alarm Alarm Memory The green LED will blink once every 16 seconds to e Low Battery Signal Will chirp alert a user when the unit has alarmed for smoke or has detected a every minute and red LED will flash hazardous concentration of CO If the alarm has detected a CO level to indicate low battery condition SIGNALING L lt S 40 UL 6 A Trans LISTED RRA of 100ppm or greater when the Test Reset button is pressed the unit will announce CO PREVIOUSLY DETECTED If the alarm has detected abnormal levels of smoke since its last test it will produce three rapid beeps This alarm uses photoelectric sensing technology Leading authorities recommend tha
5. nal pieces shall be required to activate this feature The alarm shall include a test button that will electronically simulate the pres ence of smoke and CO and cause the unit to go into both modes of alarm This sequence tests the unit s electronics to ensure proper operation The CO sensor will not alarm to levels of CO below 30 ppm and will alarm in the following time range when exposed to the corresponding levels of CO 70 ppm CO Concentration 60 240 minutes 150 ppm CO Concentration 10 50 minutes 400 ppm CO Concentration 4 15 minutes The combination alarm shall have two methods of warning for danger a piezo electric horn that is rated at 85 decibels at 10 feet and a voice warning that identi fies the danger For a CO incident the horn will sound in the repetitive manner four 4 fast beeps a short pause four 4 fast beeps a short pause In between the unit will announce Warning Carbon Monoxide After four minutes the alarm voice pattern will sound once every minute until the unit is reset or the CO eliminated In a Smoke incident the horn will sound in the repetitive man ner three 3 beeps a pause three 3 beeps a pause In between the unit will announce Fire Fire The unit shall incorporate 2 LED s A green LED will flash every 30 seconds when in standby condition every 16 seconds to indicate alarm memory and every 2 seconds to indicate the Hush mode Is active A red LED will flash in
6. t both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fires that can occur within the home lonization sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ionization alarms Architectural and Engineering Specifications The combination smoke and carbon monoxide alarm shall be Kidde Part Number CP9000 Model KN COPE D or approved equal It shall be powered by one 9V battery The temperature operating range shall be between 40 F and 100 F 4 C and 38 C and the humidity operating range shall be 10 95 relative humid ity non condensing The unit shall incorporate a photoelectric smoke sensor with nominal sensitivity of 2 5 0 95 ft The CO sensor shall be of a fuel cell design and shall meet the sensitivity requirements of Underwriters Laboratories UL2034 Single and Multiple Station Carbon Monoxide Detectors The unit shall quality for UL approved word ing on the package World s Most Accurate Carbon Monoxide Alarm The combination alarm can be installed on the surface of any wall or ceiling fol lowing the UL NFPA Manufacturer s recommended placement guidelines The unit shall provide optional tamper resistance that deters removal of the unit from the wall or ceiling No additio
7. th a photoelectric sensor for detecting smoke and fire this alarm with slow smoldering fires sooner than an ionization sensor also includes the world s most accurate CO sensing technology e Electrochemical CO sensor Provides accurate and continual CO based on claims by major manufacturers protection during the product s life remains stable during temperature and humidity changes and resists reactions to household gases that may Alarm Warnings cause false readings or reduce sensitivity Fire The red LED will flash and be accompanied by three long alarm e Smart Touch Button One button performs the following functions beeps followed by a verbal warning message FIRE FIRE The alarm Activates the Hush feature to temporarily silence nuisance alarms will repeat pattern until unit is reset or smoke is eliminated will announce Hush mode activated or Hush mode cancelled Carbon Monoxide Four short alarm beeps followed by a verbal Simultaneously tests the unit s electronics and verifies proper operation warning WARNING CARBON MONOXIDE After four minutes the Activates the peak level memory feature will announce CO previously alarm voice pattern will sound once every minute until the unit is detected if unit has detected levels of 100 ppm or higher reset or the CO is eliminated Resets the unit during a CO alarm Unit will re enter alarm within Low Battery One chirp followed by warning LOW BATTERY