Keston K50 User Instructions
Contents
1. are to positioned close to the boiler the following minimum clearances must be observed Top 254 mm Bottom 127 mm Left 1 mm Right 1 mm amp Front 305 mm Extended clearance is required to the front to allow for access for servicing Cleaning Normal casing cleaning only requires dusting with a dry cloth To remove more stubborn marks wipe with a damp cloth and finish with a dry cloth Boiler Setup 1 Check that the gas supply from the gas meter is turned ON 2 Check that the gas tap to the boiler is in the ON position i e the screwdriver slot is aligned with the gas tap 3 Switch on the electric supply to the boiler and controls and set the heating controls to call for heat 4 Check the pressure gauge to the right on the control panel on the front of the boiler This should show around 1 to 2 bar pressure for pressurised systems WD 62 1 1997 Warning If there is no pressure indicated and the system if of the pressurised type do not attempt to light the boiler Send for your Installer or Service Engineer to re pressurise the system To Light The Boiler Pressure On Off Gauge Switch Fig 1 Boiler Control Panel Switch the On Off switch to the left of the control panel on the front of the boiler to the ON position The following sequence will occur 1 In the On position the On Off switch will be lit with an amber light f the switch does not illuminate check that the electricity supply to the heati
2. WD 62 1 1997 KESTON CONDENSING BOILER Users Instructions The Gas Safety Installation And Use Regulations 1994 impose certain statutory obligations on gas users Further information regarding these regulations can be obtained from your Gas Region All gas appliances must be installed by competent persons by law in accordance with these regulations Membership of CORGI is indication of such a competent person with regard to gas installation It is in your interests and that of safety to ensure that the appliance is installed correctly and that the law is complied with Failure to do so could lead to prosecution Introduction These instructions should be carefully read to ensure safe and economical use of your boiler The Keston Condensing Boiler series are high efficiency central heating condensing boilers designed to provide central heating and indirect domestic hot water supply They are designed for use with fully pumped systems only These boilers are supplied for natural gas use but may be converted for use with LPG by installing the appropriate conversion kit This conversion must be carried out by a competent person Servicing To ensure continual safe and efficient operation of the boiler it is recommended that the appliance be checked and serviced as necessary at regular intervals Generally once per year will be sufficient It is the law that any servicing must be carried out by a competent person Clearances If fixtures
3. ice Engineer
4. ng system is on and that the controls are calling for the boiler to fire 2 At the same time the red lockout light will illuminate f neither the red lockout lamp nor green run the upper lamp adjacent to the flame symbol illuminate then the boiler is up to temperature and will automatically start when the heating temperature drops sufficiently 3 After about 15 seconds the boiler will ignite and the green run lamp the upper lamp adjacent to the flame symbol will also be illuminated The boiler is now running correctly and will proceed to switch itself on and off as the heating reaches its operating temperature If the green run lamp the upper lamp adjacent to the flame symbol goes out and the red light remains illuminated for more than two minutes due to a failure to ignite or an interruption to the gas supply turn the boiler off wait for 10 seconds and turn the boiler on again as described above in To Light The Boiler If the boiler still fails to ignite after three successive attempts contact your Installer or Service Engineer NB The Keston boiler is designed for simplicity and hence has no user adjustment Gas Leak or Fault If you suspect a gas leak turn off the appliance immediately and contact your local gas region without delay If you suspect a fault with the appliance it must not be used until the fault has been corrected by a competent person In the unlikely event of a breakdown consult your Installer or Serv
Download Pdf Manuals
Related Search
Related Contents
Long elements - Mino Remote controlled Lange Zebra P310 User's Manual Manuel d'utilisation NX650 Service manual index PRODUCTO Nº: 1 Clock with selected audio messages Poulan 413288 User's Manual KTM 400 EXC RACING Motorcycle User Manual Copyright © All rights reserved.
Failed to retrieve file