1. Two 10 32 screws Two 10 32 screws Cabinet Unit Front 1 Affix the extension brackets to the main rail using the 8 32 screw washer nut assemblies Adjust to the correct length for the cabinet depth being used FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 7 2 Extension Bracket 2 Affix the extension bracket to the rear of the unit using two 10 32 screws There are 3 holes in the extension bracket for mounting Depending on the hole pattern that is being used in the cabinet two holes should always be available for securing the extension bracket 3 The fronts of the rails have three holes Two of the holes top and bottom are used to secure the rail to the cabinet The middle hole is used to secure the Two 10 32 enclosure to the rail and n screws to secure cabinet Secure the front rail to cabinet of each rail to the cabinet vertical rails using two lm 4810 32 screws for each m rail FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 7 3 Fortra 4 Slide the unit into the cabinet and secure it to the cabinet with a single 1110 32 screw on each side 5 Snap the end cap over the screw on each side of the unit to finish the installation FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 1 4 8 SES Operation For bus management the FORTRA Force G15 and G15 2G Fibre channel enclosures have a built
2. Dimensions Weight Unit Weight 43 lbs 19 5kg Height 20 1 2 521mm Width 9 5 8 235mm Depth 24 610mm Power Supply Each power supply includes internal cooling fan Quantity 2 Power 430 Watts each N 1 Power Factor Correction Input 100 260 VAC 50 60Hz Output 5V 35A 12V 30A Blower Quantity 4 2 per cannister Size 97mm 3 82 each Air Flow 25 42CFM 0 72m3 min each Noise 52dB A Fibre Channel Features Loop Expansion FORTRA Force G15 and G15 2Gb s Fibre Channel enclosures include a loop expansion I O connector on each port This allows the connection to other Fibre Channel enclosures switches servers hubs and other Fibre devices Loop Bypass and Clock Timing Circuit Each port A amp B includes a loop bypass circuit that monitors each slot for a loop connection It has two modes of operation NORMAL and BYPASS In NORMAL mode the device is connected to the loop In BYPASS mode the device is either absent or non functional and data bypasses to the next available device until the correct device is located The unit also has a built in clock recovery circuit that adjusts the timing for any input or output that is going through the enclosure SFP CONNECTOR The FORTRA Force G15 and G15 2Gb s Fibre Channel enclosures use Small Formfactor Plugs SFP as the Fibre I O ports Dual Loops A amp B A single loop is required for unit operation however both loops can be used to connect to differ
3. Force G15 amp G15 RAID Systems 15 bay Rackmount and Tower Enclosures Installation Guide May 31 2002 Revision A Patent Pending ios JMe Fortra Copyright Copyright 2000 2001 by JMR Electronics Inc All Rights Reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form or by any means electronic mechanical photocopying recording or otherwise without the express written permission of JMR Electronics Inc Sales and Ordering Information JMR Electronics Inc 20400 Plummer Street Chatsworth CA 91311 USA Phone 818 993 4801 Fax 818 993 9173 Office Hours Monday Friday 8 00 A M to 5 00 P M Pacific Standard Time European Corporate Headquarters JMR Electronics United Kingdom Iain Pickthall P O Box 3058 Wokingham Berkshire RG40 3FU United Kingdom Phone 44 118 973 6018 Fax 44 118 973 7191 E Mail Iain jmr com Internet http www jmr com Trademarks JMR the JMR logo and FORTRA are registered trademarks of JMR Electronics Inc All other product and brand names are the property of their respective holders Changes The material in this document is for information only and is subject to change without notice JMR Electronics Inc reserves the right to make changes to this manual and the equipment described herein without notice JMR has made all reasonable efforts to ensure that the i
4. FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 5 2 6 Power Supply Operation This chapter covers all operations of the power supplies For operation the AC cord included must be connected to the AC Inlet on each supply and the power supply must be switched ON The OK LED will light to indicate the power supply is functioning properly If the power supply experiences a problem and cannot operate within its normal specifications the Fault LED will light and the power supply will shut itself off The power supplies also have their own fan included to maintain proper cooling within each supply and also provide some additional but minimal airflow through the rest of the enclosure On Off Switch mE oc o LL OKLED esser Ty Power Supply Removal Insertion Follow the following steps to either remove a power supply in a 10 15 bay unit 1 Unfasten the power supply thumbscrew by turning counterclockwise A Philips head screwdriver may be used if the thumbscrew is too tight to turn by hand 2 Remove by pulling out on the handle Reverse the steps to reinstall the power supply FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 6 1 portra Low Power Mode Standby Power When both power supplies are turned off the unit will switch to low power or standby mode and the power supply fans will continue to run The unit blowers will remain operational if a single power supp
5. Red The power supply fault LED will light and an audible alert will sound The audible alert can be turned off through SES Audible Alert There are three audible enclosure alerts that are controlled through the SES processor Two beeps indicate a temperature issue Three beeps indicate a blower failure Five beeps indicate a power supply failure FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 2 2 portra SYS FLT The SYS FLT LED on the back of the unit indicates an error on the SES bus It also indicates whether an active loop connection is established If no loop connections are established the LED will light Red 2 3 FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 3 Device Installation This chapter covers Fibre Channel device installation for both the FORTRA Force G15 and G15 rackmount and tower enclosures SCA Connection and Hot Swapping The unit uses SCA 2 40 pin connectors which provide a safe means of connection disconnection when hot swapping devices In order to hot swap devices the host adapter or RAID controller and host operating software must support the feature Any SCA drive is capable of plugging directly into the backplane of the unit and should not require any additional cabling or connections Canister Removal Insertion 1 The photo to the right shows the canister in a locked position 2 Pull the handle out to unlock the canister from the
6. E Sara SES I NP SN Ne 1 4 vi P 1 4 2 Hardware Specification Environmental Specifications dace ES RP a CREER RES 2 Electrical Specifications auus ara uie ador ERA anne 2 Apency C omplidlbtO u s err Er ER EDER EEE RES SE SS ERE DALER ES 2 Packaging Specifications aae 220 0 SE era Ake Gas doa eae 2 1 lbi P 2 2 Thermal Specifications aue venous aaa cane oes rare echan oen 2 2 Rotation Vibration Specifications 0 ccc cee eee 2 2 Fault Indication Features ea 456 Gab areas Gas See eames 2 2 PaulETHOICOIDES 4 uunc d ATLET teu esa sd ds PRSEEG PESE 2 2 JAUCIDIC ASHE neun sauren sauren eurer reset 2 2 SISHLI ae case ua 2529292253 9529299 59 199 9 9 592 925 2 3 3 Device Installation SCA Connection and Hot 5wapping else 3 Canister Removal Insertion ceeeee s 3 Drive Installation eeee RI 3 2 4 Fibre Channel JBOD Setup SHOE SCHINGS aues dcs doen aoe ausa d uda Xon 4 doi dde ates een d Sn d daft 4 SCHIED wanna ae near ahnen 4 2 1G Option Setting vera aan ann arena ae ern 4 3 BE oni near aan Gaede ae Reese eee 4 3 FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A Option Settings MP 4 4 Delayed Start Option Jumper 0 0 cece ee eee 4 4 Remote Start Option Jumper 0 0 nnana ee eee 4 4 Front Stas LEDS sou acutos bises sa taceneetseusesasa
7. in SES processor designed to meet the SFF 8067 specification In order to communicate with the SES processor at least one device must be present in the enclosure FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 8 1 Installing the Intel PCI RAID Controller This chapter covers the installation of the Intel PCI RAID Controller that is shipped with the FORTRA Force G15 and G15 RAID Systems The model number of the PCI RAID Controller is ICP Vortex number GDT8522RZ ICP Vortex is a wholly owned subsidiary of Intel Corporation Installing the PCI Controller To install the PCI Controller perform the following steps 1 Switch off the PCI computer and disconnect all cables Ensure that the power cord is removed first 2 Following the instructions in the computer manual open the case of the PCI computer so that you have easy access to the PCI expansion slots 3 Select a free 64 Bit PCI bus master slot or 32 Bit PCI bus master slot and remove the metal bracket following the instructions in your PCI computer manual It is essential that the CP Controller is plugged into a bus master slot it will NOT work in a slave or non busmaster slot 4 Push the ICP Controller firmly into the correct PCI bus master slot Make sure that the controller fits tightly into it and that the external connectors stick out of the computer case Now fix the ICP Controller by tightening the screw of its bracket 5 Reconne
8. the conflict Option Settings Two option settings are located on the mid plane board To access the jumpers the cover must be removed and the personality boards removed The diagram below shows the location of the option settings on the mid plane board FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 4 3 W1 Delayed Start amp Remote Start Located on the mid plane board L a 46 m Ss 45 Delayed Start Option Jumper Header W1 pins 1 amp 2 Jumper on enabled Jumper off disabled default Remote Start Option Jumper Header W1 pins 3 amp 4 Jumper on enabled Jumper off disabled default Front Status LEDs A status indicator is located on each canister A Blue light indicates normal drive activity A Red light indicates a device fault If all canisters display a Red light that is blinking on and off it indicates that there is a system fault A system fault is either a power supply or blower failure Check the back of the unit to determine which fault has occurred Refer to Chapter 5 for blower fault indicator location and to Chapter 6 for power supply fault indicator location otatus c m Indicators A blue light on a single canister A red light on a single canister indicates a device fault FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 4 4 portra External I O Connection The external I O connections are located on
9. the personality card There are four SFP tranceiver connectors accessible from the rear of the unit Switch Switch CH A and CH B Top Input and output connections for Loop 1 These are SFP 2Gb s transceiver connectors used to connect to a host system or to an expansion chassis CH A and CH B Bottom Input and output connections for Loop 2 These are SFP 2Gb s transceiver connectors used to connect to a host system or to an expansion chassis System SES Fault LED amp Audible Alert This red LED will light along with a buzzer if a system fault occurs A system fault includes over temperature power fault or blower fault The buzzer will sound off with a sequence of beeps to indicate the fault that has occurred 2 beeps Temperature Fault 3 beeps Blower Fault 5 beeps Power Supply Fault The light will stay on red if a fault occurs During normal operation the red light will blink to notify that internal SES monitoring is working FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 4 5 portra Mute This is a push button used to silence the Audible Alarm SYS Activity LED This is an LED for SES that will blink whenever there is activity between a host SES unit and the JMR SES processor Loop Expansion daisy chaining To connect two JMR enclosures together on the same bus the OUT port of the first enclosure is connected to the IN port of the second enclosure SES A built in SES processo
10. the warranty and could cause damage to the unit and drives The canisters should be packaged separately within the product packaging as provided Thermal Specifications FORTRA Force G15 and G15 enclosures have been designed to meet the air flow cooling requirements for popular 7 200 10 000 and 15 000 RPM disk drives Using high performance blowers air is pulled in from all open vents and exhausted out the back of the unit Rotation Vibration Specifications FORTRA Force G15 and G15 enclosures have been designed to meet the rotation vibration shock requirements for popular 7 200 10 000 and 15 000 RPM disk drives Fault Indication Features This section reviews the indicators that will notify the user of a power supply or blower that is in a fault state More information is available in Chapter 5 blowers and Chapter 6 power supply SAFETY TIP Reshipping the enclosure with canisters drives or power supplies installed in the enclosure may cause damage to these components and will void the warranty SICHERHEITSHINWEIS Der Versand des Geh uses mit eingebauten Einsch ben Platten und Netzteilen kann zur Besch digung dieser Komponenten f hren und somit den Garantieanspruch gef hrden Fault Indicators On a blower fault all the front status LEDs will blink Red The blower LED on the back of the unit will light red and an audible alert will sound On a power supply fault all the front status LEDs will also blink
11. FORTRA unit Ensure that the thumb is placed below the line Pressing the thumb against the Status LED lens could break it Notice that the locking tab slides down as the handle is pulled out SAFETY TIP After disengaging a device from the enclosure allow 10 seconds before pulling the canister out of the unit This allows the device to properly spin shut down before transport SICHERHEITSHINWEIS Nachdem ein Einschub vom Geh use wie in Step 3 gezeigt gel st wurde warten Sie bitte ca 10 Sekunden bevor der Einschub ganz heraus gezogen wird Dies erm glicht den Auslauf der Festplatte bis zum vollst ndigen Stillstand der rotierenden Scheiben f r einen sicheren Transport 3 Pull the canister straight out to remove Ensure that any installed devices are spun down before full removal to prevent damage to the drive FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 3 1 portra Follow the steps in reverse to reinstall Drive Installation Pa de Status Indicators de RE M Device Mounting Holes 4 Device mounting screws are included with the unit for device mounting The JMR part number for the 6 32 mounting screws is HDS 01906 WARNING Before device installation alleviate any electro static discharge by touching a grounded metal assembly Static can be potentially damaging to enclosure components WARNUNG Ber hren Sie vor der Festplatteninstallation geerdete Metallgegenst nde um elekt
12. M International Business Machines Corporation Internet Address www ibm com Maxtor Internet Address www maxtor com Seagate Technology Internet Address www seagate com RAID Controller Manufacturers Adaptec Inc Internet Address www adaptec com Chaparral Network Storage Internet Address www chaparralnet com Digi Data Corporation Internet Address www digidata com Infortrend Corporation Internet Address www infortrend com Intel ICP VORTEX Intelligent Computer Peripherals Internet Address www icp vortex com Mylex Corporation Internet Address www mylex com E z S Silicon Image CMD Storage Systems Internet Address www cmd com FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A A 1 portra Host Bus Adapter Manufacturers Adaptec Inc Internet Address www adaptec com Antares Microsystems Internet Address www antares com Emulex Corporation Internet Address www emulex com JNI Corporation Internet Address www jni com QLogic Corp Internet Address www qlogic com FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A A 2
13. Sie kein Stromkabel mit 2 Anschl ssen da dieses keine korrekte Erdung erm glicht und Probleme wahrend des regul ren Betriebs verursachen kann Slot Settings The pictures to the right show the slot pi Slot 0 ID 0 numbering sequence and the default ID T5 B B5 settings Default ID settings are based on both a 5 i 2 ID rotary switches set to a value of 0 Slot n ID 4 Slot 5 ID 5 Slot 6 ID 6 Slot 7 ID 7 Slot 8 ID 8 Slot 9 ID 9 Slot 10 ID 10 Slot 11 ID 11 Slot 12 ID 12 Slot 13 ID 13 Slot 14 ID 14 FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 4 1 portra Setting ID Rotary switch settings only affect Slot O and all other slots are sequentially increased by a value of one after that slot The ID is set sequentially starting 0 7 ID Switch from a base address base address base modifier The base address or _ starting address is set via a 0 7 position rotary switch located on the back of the unit There is a second 0 15 position rotary switch which can be changed to modify the base address setting Both the top and bottom switches must be set identically erage tae 0 15 ID Switch 0 7 ID Switch 0 base modifier base address The 0 7 switch is used to set the base address which is multiplied by 16 and the 0 15 switch is used to set the offset modifier to the base address The formula for setting the ID is x 16 y where x is the 0 7 switch and y is the 0 15 swi
14. Supported ot Swap Canisters emovable Power Supplies emovable Blowers 1 Power Supplies 1 Blowers IA Support FC Only oop Expansion Support FC Only aisy Chainable SCSI Only uilt in Termination SCSI Only uto Termination SCSI Only AF TE SES Ready Optional AF TE SES Compatible CSI to SCSI RAID Support ibre to SCSI RAID Support ibre to Fibre RAID Support ibre to ATA RAID Support CSI to ATA RAID Support D esktop T ower R ackmount 6 10 15 bay unit features apply to both Tower and Rackmount models 1 Features are based on a standard configuration with no internal host controller s installed 2 Fibre channel 10 15 bay enclosures have built in SES 3 Fibre Channel 2Gb Model available 2Gb models use SFP transceivers Cina Z Z Z n5 JJ Fibre only Fibre Onl Fibre only v ZU Nd AY SI AJ X Z SI AJ ST SISI NSI SINI ro ro z Z AJ S AP XP A J J X X ps V v C CU m gt s amp lt 1 SY SP SP SP XP XY SY SY SY SPS S mo m Co Fibre only Fibre only e B lt AP XP XP XP XP XP NII XP XP SE SE SISI NSI SI NSI NISN SS EI EI EA Bes es TI lt S lt S ADSL 92 31 FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 1 1 portra FORTRA Force products use advanced mid plane technology developed by JMR which allows power supplies drives and all other enclosure components to interface into a single board This provides superior perfor
15. be left in the enclosure until a replacement power supply is available FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 6 2 R15 Cabinet Installation This chapter covers the installation of the Rackmount enclosure into a standard 19 483mm wide and 30 762mm to 36 914mm deep cabinet that meets the EMA RETMA standards Before beginning rail installation please take note of the following precautions NOTE When installing the unit into a cabinet or closed environment the operating ambient temperature of the rack environment may be greater than the maximum recommended ambient temperature Consideration must be taken to meet the maximum recommended ambient temperature Tmra for the best unit operation HINWEIS Wenn das Ger t in einen Geh useschrank oder eine sonstige geschlossene Umgebung verbaut wird kann die Umgebungstemperatur ber die maximal zul ssige Betriebstemperatur ansteigen MaBnahmen bzgl der maximalen empfohlenen Betriebstemperatur Tmra m ssen getroffen werden um eine bestm gliche Funktion des Ger tes zu gew hrleisten WARNING Ensure that the front and back of the unit are not blocked when installing the unit into a cabinet or closed area Blocking the front or back of the unit can cause reduced air flow that will compromise the safe operating environment within the unit WARNUNG Vergewissern Sie sich da das Ger t an Vorder und R ckseite nicht abgedeckt ist wenn das G
16. ct the PCI computer systems covers cables and lastly the power cord 6 Before powering up the PCI computer system connect the Fibre Channel cable cables to the G4 sub system The cable to be used should have a HSSDC connector at one end and a HSSDC2 connector at the other end 7 The PCI computer system is now ready to be powered up Configuring RAID Sets To configure the RAID sets refer to the ICP Vortex User Manual located on the CD shipped with the FORTRA Force G15 and G15 RAID Systems FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A E z S 9 1 10 Product Support For current information on this product including updates to the manual and technical support related issues please contact the sales support section of our web page at www jmr com or you can contact our Technical Support division directly at the address below US Corporate Headquarters JMR Electronics Inc ATTN Technical Support Division 20400 Plummer St Chatsworth CA 91311 Customer Support 818 739 1140 E mail techsupport jmr com Office Hours Monday Friday 8 00 A M to 5 00 P M Pacific Standard Time Internet http www jmr com Manual Changes Revision A Initial Release FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 10 1 lix A DRIVE AND CONTROLLER MANUFACTURERS Drive Manufacturers Fujitsu Internet Address www fcpa com Hitachi Internet Address www hitachi com IB
17. enenes lt 4 4 External I O Connection unsere RPG der m y deed 4 5 CH A and CH B Top eeelee ees 4 5 CH A and CH B Bottom eee RR 4 5 System SES Fault LED amp Audible Alert Lsss 4 5 WAG ee 4 6 SYS Activity LED i5 ses stba sek ee Ra ESAE CERE A X ERES 4 6 Loop Expansion daisy chaining 0 00 cece eee eee 4 6 v EO een E E teren 4 6 5 Blower Operation Blower Removal Insertion llle 5 1 blower Replacement van nennen either eier 5 2 6 Power Supply Operation Power Supply Removal Insertion llle 6 1 Low Power Mode Standby Power lesser 6 2 Power Supply Replacement a ace acne ana 6 2 7 FR15 Cabinet Installation Rail Mounting Kit Hardware 0 0 0 ce eee 7 2 Spate Hardware Parts 422 0202000 200 deine coe ORO e m on 7 2 Rail Installation A a 7 2 8 SES Operation 9 Installing the Intel PCI RAID Controller Installing the PCI Controller 22 2524 d xor ee seen ES Y ee 9 1 Confisurms RAID Ses 6 na ER netten et 9 10 Product Support US Corporate Headquarters x22 6 2 9o he orm IR en tae eee 10 1 Manual Changes ea eae dure x estin eiu auci s eit aed et 10 1 Appendix A Drive and Controller Manufacturers Drive Manufacturers 2 20 2 cc cee es A 1 RAID Controller Manufacturers RR A 1 Hos
18. ent hosts dual host adapters and other devices for flexible and even redundant configurations For specific connection and installation information refer to Chapter 4 FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 1 3 portra ID Selection 0 127 device ID addresses are addressable and can be easily set up via ID rotary switches located on the personality modules For specific connection and installation information refer to Chapter 4 SES FORTRA Force G15 and G15 2Gb s fibre channel enclosures have a built in SES processor on the personality card See Chapter 8 for SES information FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A Hardware Specification This chapter covers specification information for all FORTRA Force G15 Tower and G15 Rackmount or Tower enclosures Environmental Specifications Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 0 C to 65 C 32 F to 149 F The maximum recommended ambient temperature depends on the recommendation of the manufacturer for the devices being installed Electrical Specifications AC Inlet Type IEC320 EN60320 Power Cord NEMAS ISP Power Supply Auto switching for 110 220V operation Agency Compliance FORTRAS Force G15 and G15 enclosures have been designed and built to comply with the FCC Class A UL CSA TUV CE and C Tick standards For more information on FCC Class A compliances
19. er t in einem Geh useschrank oder einer geschlossenen Umgebung verbaut wird Abdeckung der Vorder und R ckseite kann verminderte K hlung zur Folge haben und somit sichere Betriebsbedingungen negativ beeinflussen WARNING When loading the unit into a cabinet ensure that a hazardous condition is not achieved due to uneven mechanical loading To prevent injury remove the power supplies and drives before loading and re install them after the unit has been secured in the cabinet WARNUNG Vermeiden Sie w hrend des Einbaus des Ger tes in einen Geh useschrank jegliche gef hrliche Aktionen selbst wenn diese nur mechanischer Art sind Um Verletzungen zu vermeiden entfernen Sie die Netzteile und Laufwerke vor der Montage und installieren Sie diese erst erneut wenn das Ger t im Geh useschrank gesichert ist Vergewissern Sie sich daB das Ger t an Vorder und R ckseite nicht abgedeckt ist FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 7 1 Fortra Rail Mounting Kit Hardware Gum Ten 10 32 Screws Four each 8 32 Screws Washers Nuts o Spare Hardware Parts Check with a JMR Sales Representative for pricing and availability of spare hardware parts Description JMR Part Number 110 32 Screw HDS 01580 48 32 Screw HDS 00350 8 32 Nut HDN 00040 8 32 Washer HDW 00080 Rail Installation A completed rail assembly without the unit uinstalled would look like this Two 8 32 screw assemblies
20. ly is turned off not installed or fails in order to maintain the proper low temperature within the unit To stop the power supply fans and turn the unit off completely it must be disconnected from the AC power source Power Supply Replacement If the Power Supply Fault LED indicator is lit the power supply may need to be replaced Before replacing the power supply should be turned off removed from the enclosure and reinstalled The AC cable connection should be checked to ensure that the connector is firmly seated and the power supply should be firmly inserted with the thumbscrew tightly securing it If the Fault LED indicator is still coming on then the power supply should be replaced If the fan in the power supply is not functioning but the power supply still works the power supply unit should be replaced as soon as possible Leaving the power supply running without the fan could cause the power supply to overheat and shutdown at any time If you believe a power supply is in a nonfunctional state please contact the place of purchase for repair or replacement JMR part number for a replacement power supply is shown below The assembly includes the power supply installed in the canister Model JMR Part Number 15 bay PSS 00721 SAFETY TIP Both power supplies should be installed into the unit at all times to maintain proper cooling and airflow within the enclosure In the event of a power supply failure the faulty supply should
21. mance and easy connectivity The host interface supports a SFP Small Formfactor Plug Fibre Channel transceiver at 2Gb s All FORTRA Force G15 amp G15 RAID Systems Fibre enclosures have built in SES on the personality card that allows control and monitoring of some enclosure components using SES commands through the host FORTRA Force G15 RAID System Components The FORTRA Force G15 RAID System contains the following components One Fortra 15 bay Rackmount or Tower Enclosure One Intel 2G PCI Fibre RAID Controller Fifteen Seagate 73G HDDs Two 2G Copper Fibre Cables HSSDC to HSSDC2 FORTRA Force G15 RAID System Components The FORTRA Force G15 RAID System contains the following components Two Fortra 15 bay Rackmount Enclosures One Intel 2G PCI Fibre RAID Controller Thirty Seagate 36G or 73G HDDs Two 2G Copper Fibre Cables HSSDC to HSSDC2 Rackmount Specifications Dimensions Weight Unit Weisht 40 Ibs 18 2kg Height 5 1 4 3U 133mm Width 19 483mm Depth 23 584mm Power Supply Each power supply includes internal cooling fan Quantity 2 Power 430 Watts each N 1 Power Factor Correction Input 100 260 VAC 50 60Hz Output 5V 35A 12V 30A Blower Quantity 4 2 per cannister Size 97mm 3 82 each Air Flow 25 42CFM 0 72m3 min each Noise 52dB A FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 1 2 portra Tower Specifications
22. nformation in this manual is accurate and complete However JMR shall not be liable for any technical or editorial errors or omissions made herein or for incidental special or consequential damage of whatsoever nature resulting from the furnishing of this manual or operation and performance of equipment with this manual Disclaimer The original product packaging has been tested and is safe under normal shipping circumstances Reshipping the product without using the original product packaging will void the warranty Do not ship the unit with canisters or power supplies installed as this will void the warranty and could cause damage to the unit and drives The canisters should be packaged separately within the product packaging as provided FCC Information The FORTRA equipment generates uses and can radiate radio frequency energy If the FORTRA Array is not installed and used properly that is in strict compliance with these instructions it may cause interference to radio and television reception The FORTRA equipment and its contents are designed to comply with the limits for a Class A computing device in accordance with the specifications in Part 15 of FCC rules These rules are designed to provide reasonable protection against radio interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation Operation of this equipment in a residential area is likely to cause i
23. nterference in which case the user at his own expense will be required to take whatever measures are necessary to correct the interference WARNING Changes or modifications not expressly approved by the manufacturer could void the user s authority to use the equipment WARNUNG Nicht ausdr cklich durch den Hersteller genehmigte Anderungen oder Modifikationen k nnen die Erlaubnis Zur benutzung der Produkte gefahrden You may find the FCC booklet How to Identify and Resolve Radio Interference Problems helpful This booklet is available from the U S Government Printing Office Washington DC 20402 Stock 004 000 00345 4 Printed in the USA Part Number PUB 00281 Revision A May 2002 SCS Patent Pending FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A ll Fortra Table of Contents 1 Introduction FORTRA Product Family Features 0 000 0 000 cee eee 1 1 FORTRA Force G15 RAID System Components 1 2 FORTRAS Force G15 RAID System Components 1 2 Rackmount Specifications 4 229393 3 93 ee 1 2 Tower Specifications 2559 x 93k nm ROUES ES q en eee EER 1 3 Fibre Channel Features 34 evxci medo wnesE Ud FEX TP ee 1 3 Loop Expansion area 2252144224225 744 UREREdOET PR EDE M E S a 1 3 Loop Bypass and Clock Timing Circuit 1 3 SFP CONNECTOR cerca e Rd x CREE ERAS CER A X ERES 1 3 Dual Loops A amp B seen eee ee enes 1 3 ID SCICCHOM o ox 25
24. r provides in band bus management for the unit Refer to Chapter 8 for information about the SES processor FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 4 6 5 Blower Operation This chapter covers all operations of the blowers for FORTRA Force G15 and G15 units Refer to Chapter 1 for blower specifications The blowers are hot swappable and can be removed or installed while the enclosure continues to function however failure to replace a non working blower within a reasonable period of time may expose drives to extreme heat which could cause loss of data WARNING Blowers are a system critical component Non operating blowers should be replaced as soon as possible to avoid data loss or device failure WARNUNG Geblase sind fur die Funktion wichtige Komponenten Nicht funktionierende Gebl se sollten so schnell wie m glich ersetzt werden um Datenverluste oder Fehlfunktionen zu vermeiden The blowers are located on the back of the unit and each has its own fault LED that will light if the blower is non operational Blower Removal Insertion The blower is designed to be easily installed and removed 1 Unfasten the blower thumbscrew by turning counterclockwise A Philips head screwdriver can be used if the thumbscrew is too tight to turn by hand 2 Remove the blower sled by pulling out on the handle and grasping the side of the blower tray Wait for the blower to stop completely before
25. removing it from the unit Reverse the steps to reinstall the blower WARNING To prevent injury when removing or installing the blower do not grab the bottom of the tray which is used for blower access intake The blower operates at high speeds and continues to spin for a short time after power is disconnected WARNUNG Um Verletzungen w hrend der Entfernung oder Installation des Gebl ses zu vermeiden berthren Sie nicht dessen Unterseite da hier der Lufteintritt erfolgt Das Gebl se arbeitet mit hohen Geschwindigkeiten und l uft nach Abschalten der Versorgungsspannung noch einige Zeit nach FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 5 1 User s removing or installing a blower must be awarre of the blower access hole Contact with the access hole must be avoided while the blower is running to prevent injury Blower Replacement If the blower has stopped running or the fault LED indicator is lit the blower may need to be replaced Before replacing the connection should be checked to ensure that the connector is firmly seated and that there is nothing blocking the blower blades that could cause interference If a blower is believed to be in a nonfunctional state please contact the place of purchase for repair or replacement The JMR part number for a replacement blower is shown below The assembly includes the tray along with the blower Model JMR Part Number 15 bay SBA 05207
26. ro statische Aufladung abzuleiten Statische Aufladung kann elektronische Gehausekomponenten schwer besch digen WARNING The 6 32 mounting screws that are provided have been specially designed to fit the canisters Do not install the device using any other screws than the ones provided WARNUNG Die mitgelieferten Befestigungsschrauben 6 32 wurden speziell f r die Einsch be angefertigt und zur Befestigung der Festplatte sollten Sie keinesfalls andere als diese verwenden 1 After removing the canister place it on a static free surface along with the device to be installed 2 Place the device in the canister and mount it using the provided screws use 4 screws to mount the drive 3 Replace the canister into the unit by following the steps for Removal of a Device Canister but in reverse order FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 3 2 portra 4 Repeat steps through 3 until all devices are installed then move onto step 5 to complete unit setup and installation 5 Configure ID and other options as required See Chapter 4 for Fibre Channel device setup 6 Install and configure SES and other optional features See Chapter 8 7 For rackmount units refer to Chapter 7 to install the enclosure into a cabinet 8 Establish host connection See Chapter 4 for Fibre Channel host connection FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 3 3 re Channel JBOD Set
27. see page 2 Packaging Specifications FORTRA Force G15 and G15 packaging has been designed to be reusable and recyclable Drives may be installed and shipped in the canisters as long as the canisters are not installed in the enclosure Shipping the unit with canisters and or power supplies installed in the enclosure may cause damage to the enclosure or to the drives and will void the warranty Packaging complies with ISTA International Safe Transit Association standards and has been ISTA certified Each canister is pre packaged in an anti static bag Do not throw the packaging away if the product is intended for re shipping When transporting or shipping a JMR approved shipping container must be used SAFETY TIP Reshipping the enclosure with canisters drives or power supplies installed in the enclosure may cause damage to these components and will void the warranty SICHERHEITSHINWEIS Der Versand des Geh uses mit eingebauten Einsch ben Platten und Netzteilen kann zur Besch digung dieser Komponenten f hren und somit den Garantieanspruch gefahrden FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 2 1 portra Disclaimer The original product packaging has been tested and is safe under normal shipping circumstances Reshipping the product without using the original product packaging will void the warranty Do not ship the unit with canisters and or power supplies installed in the enclosure as this will void
28. t Bus Adapter Manufacturers 0 00 c eee eee eee A 2 FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A IV 1 Introduction The FORTRA Force G15 amp G15 RAID Systems are prepackaged 2G Fibre to 2G Fibre RAID solutions designed to be used with the included Intel PCI Dual 2G Fibre Channel host controller to provide a high end RAID system solution The following is a summary of the FORTRA Force G15 amp G15 RAID Systems features e The FORTRA Force G15 RAID Systems Tower enclosure supports up to fifteen 3 5 LP SCA 40 pin SCA drives This 2G Fibre Channel enclosure has dual ports A amp B and has additional connections on each port for loop expansion The G15 RAID System comes with the Intel PCI Dual 2G Fibre Channel RAID Controller The FORTRA Force G15 amp G15 RAID System Rackmount enclosures are 19 wide 3U 5 1 4 high rackmount enclosures that supports up to fifteen 3 5 LP SCA 40 pin SCA drives All other features are the same as the FORTRA Force G15 RAID System Tower FORTRA Product Family Features FORTRA and StorBlade are families of high end RAID Systems enclosures The following table shows the features of the FORTRA and StorBlade products 2 bay 4 bayi3 6 bay 1 3 8 bay 10 bay 72 12 bay 15 bay 1 StorBlade 10 12 15 CO Number of Device Bays umber of Blowers umber of Power Supplies umber of I O Channels SCSI Only CSI SE LVD Supported ibre Channel
29. tch Example The 0 7 switch is set to 2 the 0 15 switch is set to 6 This sets the base address to 38 2 16 32 6 38 So Slot 0 ID 38 Slot 1 ID 39 Slot 2 ID 40 Slot 3 ID 41 etc up to Slot 14 ID 52 The table below provides the Slot O Starting Base Address Settings FORTRA FORCE G15 amp G15 RAID System Installation Guide Rev A 4 2 o J De px e a o o pm i Cx pepe EDER ENIS C3 ps e 9pm FREIE ERIE EUS Ts 7 Is p pus ee n er o o ps ss pe pe a s mp9 pp Lap pss p9 pe ESS 7 Lx pe 7e 9 pm p 1 NE 5 IN 8 LR EN LE ES 5 LM Un w N wI Gy C2 SIT oO N D m OP C2 NI NIE NI NINI NI NI NINI NI OI oJ I SI Al WI BI wl DO SS Wl 00 D le pk On 4 N 1G Option Setting By setting the rotary switch settings to 7 F the enclosure will operate in 1G mode Both the upper set of switches and lower set of switches must be set to the same value The drive ID s will revert to the default value of 0 14 and can not be changed Therefore if daisy chaining to another enclosure care must be taken not to use the same drive ID s on the same loop ID Conflict When two devices share the same ID a conflict occurs This should not happen unless two or more enclosures are daisy chained together If devices in one enclosure conflict with devices 1n another enclosure the devices will re arbitrate ID and resolve
30. up This chapter covers Fibre Channel device configuration and option settings The FORTRA Force G15 and G15 have built in SES on the personality card Refer to Chapter 8 for SES operation Please take note of the installation warnings below before beginning setup WARNING Take care when connecting the unit to an AC power source to ensure that it is plugged in to a circuit of the appropriate rating 110v or 220v For safe operation the circuit should have over current protection to prevent damage to the unit in the event of circuit overloading WARNUNG Vergewissern Sie sich daB die Netzspannung 220V 110V korrekt eingestellt ist bevor Sie das Ger t mit dem Stromnetz verbinden Zur Sicherheit sollte das Netz ber einen berspannungsschutz zur Vermeidung von Sch den im Falle einer Uberlast verf gen WARNING When connecting the unit to an AC outlet or power strip ensure that the outlet has the proper connection for grounding The AC power cables included with the unit have three prongs one of which is used for the ground connection Do not use a two prong AC cable with the unit since this will not allow for proper unit grounding and could cause problems with normal unit operation WARNUNG Bei der Verbindung der Unit mit einer Steckdose oder einer Verteilerdose sollten sie auf eine korrekte Erdung derselben achten Die mitgelieferten Kaltger teanschluBkabel habe 3 Kontakte von denen einer zur Erdung verwendet wird Verwenden

Download Pdf Manuals

image

Related Search

Related Contents

Smeg SY62MX8 cooker  ProQuest - User Guide New Platform  lllilll 5. Frequently Asked Questions  Platos de ducha. Shower trays. Receveurs de  carburateur - Fichier PDF  The vmargin Package  Operating Instructions  seg royal diamond,sa royapox 511  Samsung SC6340 Benutzerhandbuch  Actron KAL 3840 Automobile User Manual  