Home
Jenn-Air JXT8142ADS User's Manual
Contents
1. 1 Duct Cover Assembly 2 pieces 1 Parts Bag 1 Duct Cover Mounting Bracket 2 Mounting Brackets Packet of Mounting Screws 2 Metallic Filters 1 Metallic Bitterfly Damper NO DUCTING IS INCLUDED INSTALLATION MOUNTING HEIGHTS amp CLEARANCE 29 46 65 5 31 Min 24 Max 32 Min 89 94 Max 113 71 E ee DUCTING A minimum of 6 round or 3 1 4 x 10 rectangular duct must be used to maintain maximum air flow efficiency Always use rigid type metal ducts only Flexible ducts could restrict air flow by up to 50 Also use calculation on right to compute total available duct run when using elbows transitions and caps ALWAYS when possible reduce the number of transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long reducer instead of a pancake reducer Reduce duct size as far away from open ing as possible If turns or transitions are required Install as far away from opening and as far apart between 2 as possible Minimum mounting height between range top to hood bottom should be no less than 24 Maximum mounting height should be no higher than 32 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will lose perf
2. 32 po Dimension minimale du conduit Rond d un diam tre minimum de 15 2 cm 6 po Des conduits rectangulaires n cessitent l utilisation d un adaptateur en vente dans la plupart des quincailleries Calcul du trac de conduits Trac maximum conduit 15 2 cm ou 8 3 cm x 25 4 cm 6poou3 30 5 M 100 PI 1 4 po x 10 po D duisez chaque coude de 90 o utilis 4 6 M 15 Pl chaque coude de 45 o utilis 2 7 M 9 Pl chaque transition de 15 2 cm 8 3 cm x 25 4 cm 6 po 3 1 4 x 10 po utilis e 0 3 M 1 Pl chaque transition de 8 3 cm x 25 4 cm 15 2 cm 3 1 4 po x 10 po 6 po 1 5 M 5 Pl Capuchon mural lat ral avec registre 9 1 M 30 Pl Capuchon de toit 9 1 M 30 PI p ex 1 capuchon de toit 2 coudes de 900 1 coude de 450 utilis 9 1m 9 1m 2 7 m 20 9 m 30 pi 30 pi 9 pi 69 pi utilis s 9 4 m 31 pi disponible pour les trac s en ligne droite INSTALLATION 4 CANALISATION AN AVERTISSEMENT DE RISQUE D INCENDIE Lair ne doit JAMAIS tre vacu et le syst me de conduits ne doit JAMAIS se terminer dans des espaces entre les murs des vides sanitaires des plafonds des greniers ou des garages Toutes les sorties de ven tilation doivent tre canalis es vers l ext rieur Utilisez seulement des syst mes de conduits m talliques Fixez tous les assemblages l aide de vis t lerie et rubaner tous les raccords l aide de ruban arge
3. Una campana instalada a muy baja altura puede sufrir da os debido al calor y correr peligro de incendio Una campana monta da a mucha altura ser dif cil de alcanzar y perder eficacia Si est n disponibles v anse tambi n los requisi tos de espacio libre correspondientes al fabricante de la cocina y la altura de montado de campana recomendada para su cocina Hay equipos de extensi n disponibles para acomodar techos de 2 7m 3 65m 10 12 Espacio libre m nimo entre el techo y la campana debe ser de 228 45cm 88 94 cuando la altura de montado de la campana es de 61cm 24 Espacio libre m nimo entre el techo y la campana debe ser de 288 82cm 113 71 cuando la altura de montado de la campana es de 81 3cm 32 Tama o M nimo de la Tuber a Redonda 6 m nimo Rectangular requiere un adaptador f cil de conseguir en cualquier ferreter a o quincaller a Tabla de C lculos para la Tuber a Largo m ximo Tuber a de 6 6 3 1 4 x 10 100 FT Deduzca Por cada codo de 90 15 FT Por cada codo de 45 9 FT Por cada transici n de 6 a 3 14 x 10 1FT Por cada transici n de 3 14 x 10 a 6 5 FT Casquete Lateral de Pared c regulador de tiro 30 FT Casquete de Techo 30 FT ej 1 casquete de techo 2 codos de 90 1 codo de 45 30 30 9 69 usados 31 disponibles para que corra recto el tubo de extracci n INSTALA
4. cap w gravity damper INSTALLATION 5 SPECIFICATIONS ELECTRICAL All Electrical work must by performed by qualified electrician or person with similar technical know how and background For personal safety remove house fuse or open circuit breaker before beginning installation Do not use extension cord or adapter plug with this appliance Follow National electrical codes or prevailing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product Cable Lock A A cable locking connector not supplied might also required by local codes Check with local E requirements and codes purchase 1 and install appropriate connector if necessary Cable Lock INSTALLATION 6 INSTALLATION N Dimensions of Support Arms 23 25 Support Arms with Tabs position Fasten Ceiling Plate Mounting the Range Hood 1 Add and secure blockings minimum 2x4 studs onto ceiling joist 2 Center mark and fasten Ceiling Plate onto ceiling where hood is to be hung Make sure front of bracket is facing as shown on diagram 3 Determine height of hood measure and attach four support arms onto blower unit with screws provided
5. conectado a tierra Debe estar protegido por un interruptor de 15 6 20 amperios o por un fusible de tiempo retrasado El cableado debe ser de 2 cables con conex i n a tierra V ase tambi n el Diagrama lt t El ctrico en la etiqueta del producto e Seguro de Cable t lt gt Un conector para asegurar el cable nose q o i O incluye puede ser requerido por los c di i w gos locales Verifique los c digos y requerimientos locales compre e instale el conector apropiado si fuera necesario Seguro de Cable INSTALACION Dimensiones de los brazos de soporte 23 25 Posterior Agregue los 12 A bloqueadores Ea Brazos de soporte con posici n de proyecciones Asegure la placa para el techo Montando la Campana de Cocina 1 Agregue y afirme los bloqueadores al techo m nimo postes de 2x4 2 Centre marque y asegure la Placa para el Techo en el lugar donde se colgar la campana Aseg rese de que la parte frontal del sujetador de pared est en la direcci n indicada en el diagrama 3 Determine la altura de la campana mida y fije cuatro brazos de extensi n a la unidad de extracci n con los tornillos que se proporcio nan utilice los orificios pre hechos en la unidad de extracci n y en los brazos de soporte Aseg rese de que las proyecciones de la parte superior de los brazos de soporte est n dirigidas hacia afuera para el frente y hacia los lados para la parte posterio
6. indicate when carbon filter replacement is required Ducting 6 straight pipe 1 Install a 6 straight pipe and a T connector or a 90 elbow to divert air through louvers on duct cover HOTTE DE CUISINI RE Num ro de mod le JXT8136ADS JXT8142ADS Num ro du fabricant S98M90S S98E42S Dimensions 35 3 8 90 cm 42 106 68 cm INSTALLATION GUIDE TABLE DES MATIERES Consignes CS SE CUP NS said 1 List des Matera 2 Hauteurs d montage 3 Comalapa 4 Caract ristiques techniques sans anse 5 nta rad diia 6 8 JENN AIR Form No A 04 03 Pi ce No 1S9800 0303A 2004 Maytag Appliances Sales Co Litho tats Unis GUIDE D INSTALLATION Veuillez lire toutes les directives avant d installer et de faire fonctionner cet appareil MODELE JXT8136ADS JXT8142ADS AVIS DE S CURIT IMPORTANT AVERTISSEMENT Installation Les proc dures d installation d crites dans ce guide s adressent des installateurs qualifi s des techniciens de service ou des personnes poss dant des comp tences similaires NE ten tez PAS d installer cet appareil vous m me L installation de l unit peut causer des blessures en raison d un manque de connaissances techniques et lectriques Tout le c blage lectrique doit tre correctement install isol et mis la masse Les vieux sys t mes de conduits doivent tre d barrass s de toute accumulation excessive de graisse
7. pour la fixer au plafond Attachez le cadre de support la plaque d assujettissement l aide des vis fournies Attachez le cadre de support 7 Branchez la canalisation et les composants l ctriques a la soufflante Remontez les caches de conduits en les faisant glisser pour acc der la partie sup rieure de la soufflante INSTALLATION 7 INSTALLATION crochets de montage Montage de la Hotte de Cuisini re 8 Soulevez le d flecteur et enclenchez les languettes de verrouillage dans la soufflante 9 Fixez le d flecteur la soufflante l aide des vis fournies en vissant depuis l int rieur du d flecteur 10 Poussez la section du conduit t lescopique vers le haut pour qu elle repose en place et puis fixez Note Le filtre Papillon registre pillon peut s installer au dessus de l habit cle du moteur INSTALLATION TRANSFORMATION EN SYST ME DE RECYCLAGE La transformation de cette unit en syst me de recyclage est recommand e pour des applications o il est impossible d installer un syst me de conduits d vacuation Lors de la conversion la hotte fonc tionne en tant qu l ment d puration plut t qu l ment d vacuation L air vici ou les manations de cuisson sont aspir s et filtr s par un ensemble de filtres au charbon Lair est ensuite purifi et recircul l int rieur de la maison ll est recommand de TOUJOURS vacuer l air l ext rieur de
8. use predrilled holes on blower unit and support arms Make sure tabs on top of the arms are facing out for the front and sideways for the rear as shown on diagram Attach support U bracket 4 Slide telescopic duct covers onto the top of the blower unit 5 Attach duct work to the ceiling and position the electrical 6 Lift blower unit and fasten to Ceiling Plate lock tabs on support frame into slots on CeilingPlate secure support p gt frame to Ceiling Plate with screws provided a gt 7 Connect duct work and electrical to the blower unit d slide duct covers up to gain access to the top of the lt 9 blower unit Support Bracket INSTALLATION 7 INSTALLATION locking tabs Mounting the Range Hood 8 Lift canopy and snap locking tabs into blower unit 9 Fasten canopy to blower with screw pro vided from inside of canopy 10 Push telescopic duct section up in place and fasten Note Butterfly damper may be installed by placing it ontop of the motor housing INSTALLATION ES DUCTLESS CONVERSION Ductless conversion is intended for applications where an exhaust duct work is not possible to be installed When converted the hood functions as a purifying hood rather than an exhaust hood Fumes and exhaust from cooking is drawn and filtered by a set of optional Carbon Filters The air is then purified and re circulated back within the home We recommend to ALWAYS exhaust air ou
9. CION 4 TUBERIA DE EXTRACCION rN ADVERTENCIA PELIGRO DE INCENDIO NUNCA haga escapar el aire o termine las tuber as entre espacios de la pared sofitos techos ticos o garajes Todos los escapes de aire deben ser dirigidos hacia el exterior Use tuber as met licas solamente Asegure todas las conexiones con tornillos para metal laminado y selle todas las junturas con cinta adhe siva certificada Silver Tape o DuctTape Algunas Opciones para la Tuber a de Extracci n Inclinaci n de Tejado c Vierteaguas y os o casquete later l de pared c regulador de tiro por gravedad il I pod Sofito o intrad s INSTALACION 5 ESPECIFICACIONES 9 p sn INSTALACION ELECTRICA Z ADVERTENCIA Toda instalaci n el ctrica debe ser realizada por un electricista calificado o por una persona con conocimientos t cnicos similares y con experiencia equivalentes Para su seguridad personal retire los fusibles del hogar o el interruptor abierto antes de comenzar la instalaci n No utilice alargadores ni adaptadores de tomacorriente con este electrodom stico Siga los c digos del National Electric Code NEC o las leyes y c digos locales reinantes Suministro El ctrico Esta unidad requiere un suministro el ctrico de 120V 60Hz y que est conectada a un circuito individ ual de derivaci n que est debidamente
10. JXT8136ADS JXT8142ADS IIMPORTANTE AVISO DE SEGURIDAD ADVERTENCIA Instalaci n La instalaci n descrita en este manual ha sido preparada para instaladores calificados t cnicos de servicio o personas con un entrenamiento similar y calificado NO intente instalar este elec trodom stico ud mismo La instalaci n de esta unidad sin el apropiado conocimiento t cnico y el ctrico puede resultar en serios da os personales Todo el cableado el ctrico debe ser instalado aislado y conectado a tierra de manera apropia da Se debe limpiar el acumulamiento de grasa en los conductos antiguos o se deben reem plazar por conductos nuevos para evitar la posibilidad del incendio de la grasa Revise todas las junturas en los conductos para asegurar que las conexiones est n bien hechas y que todas las junturas est n selladas con cinta Este electrodom stico pesa 75 Ibs Se requiere de dos personas para levantar este elec trodom stico durante su instalaci n Por favor est atento a las ltimas revisiones de las especificaciones t cnicas antes de desconectar o realizar cualquier trabajo en la unidad LISTA DE MATERIALES 1 Cuerpo de la campana 1 Ensamblado de la cubierta del conducto 2 partes 1 Bolsa de partes 1 Sujetador de montaje para la cubierta del conducto 2 Sujetadores de montaje Paquete de tornillos de montaje 2 Filtros met licos 1 Regulador de tiro de chimenea met lico tipo mariposa NO SE I
11. NCLUYE LA TUBERIA DE EXTRACCION INSTALACION A PT 29 46 65 5 31 Min 24 Max 32 Min 89 94 Max 113 71 ee TUBERIA DE EXTRACCION Para mantener una maxima eficiencia en el flujo de aire se debe usar una tuberia redonda de un minimo de 6 de di metro o una tuber a rectangular de 3 1 4 por 10 Use tuber as met licas r gidas solamente Las tuber as flexibles pueden restringir el flujo de aire hasta en un 50 Use la tabla de c lculos que se encuentra a la derecha para calcular el total de tuber a cuando se usan codos transiciones y casquetes SIEMPRE que sea posible reduzca el n mero de tran siciones y vueltas Si se necesita una tuber a de extracci n muy larga aumente el tama o de la tuber a de 6 a 7 u 8 Si se usa un reductor instale un reduc tor largo en vez de un reductor plano Reduzca el tama o de la tuber a lo m s lejos de la apertura de la campana como le sea posible Si se requieren vueltas y transiciones Inst lelas lo m s lejos posible de la apertura y distanciadas unas de otras entre 2 si le es posible ALTURA DE MONTADO Y ESPACIO LIBRE La altura m nima de montado entre la parte inferi or de la campana y la parte superior de la cocina no debe ser inferior a 24 La altura de montado m xima no debe ser superi or a 32 Es importante instalar la campana a la altura de montado apropiada
12. RANGE HOOD Model Number JXT8136ADS JXT8142ADS Manufacturer Number S98M90S S98E42S Size 35 3 8 90 cm 42 INSTALLATION GUIDE TABLE OF CONTENTS Safety MSU MCUGN Seauasisyocunuvsibersiate dul adidas 1 Listof Material rana 2 Mounting Heights sissssrssrirsiserisssinri irsi 3 DUI Bra 4 Special 5 Installation JENN AIR Form No A 04 03 Part No 1S9800 0303A 2004 Maytag Appliances Sales Co Litho U S A INSTALLATION GUIDE Read all Instructions before Installing and operating this appliance MODEL JXT8136ADS JXT8142ADS IMPORTANT SAFETY NOTICE A WARNING Installation The installation in this manual is intended for qualified installers service technicians or persons with similar qualified background DO NOT attempt to install this appliance yourself Injury could result from installing the unit due to lack of appropriate electrical and technical background All electrical wiring must be properly installed insulated and grounded Overly accumulated grease in old duct work should be cleaned out or duct work should be replaced if necessary to avoid the possibility of a grease fire Check all joints on duct work to insure proper connection and all joints should be properly taped This appliance weighs 75 lbs Two persons are required to lift this appliance during installation Please check for latest specification revisions before any custom work or cutouts LIST OF MATERIALS 1 Hood Body
13. Si cela est impossible les conduits doivent tre remplac s afin d viter les incendies de graisse Assurez vous que les raccords des syst mes de conduits sont solidaires et ad quatement ruban s Cet appareil p se 75 Livres 34 Kg Deux personnes sont n c ssaires pour soulever l appareil lors de son installation Veuillez vous procurer les r visions les plus r centes des caract ristiques techniques avant de proc der des travaux sur mesure ou de d coupe LISTE DES MAT RIAUX 1 Hotte 1 Caches de conduits 2 1 Sachet de pi ces 1 Languettes de montages des caches de conduits 2 Languettes de montages Paquet de vis de montage 2 Filtres M taliques 1 Filtre Papillon registre AUCUNE CANALISATION N EST INCLUSE INSTALLATION A PT 29 46 65 5 31 Min 24 Max 32 Min 89 94 Max 113 71 ee CANALISATION Un conduit rond d un diam tre minimum de 15 2 cm 6 po ou un conduit rectangulaire de 8 3 cm x 25 4 cm 3 1 4 po x 10 po doit tre utilis pour assurer une cir culation d air optimale Utilisez toujours des conduits m talliques rigides Les conduits flexibles r duisent la circulation d air dans une proportion qui peut atteindre 50 Utilisez toujours les valeurs de droite pour calculer le trac de conduits possibles lors de l utilisation de coudes de transitions et de capuchons Utilisez TO
14. UJOURS un nombre minimal de transitions et de courbes Pour un long trac de conduits aug mentez les dimensions des conduits de 15 2 cm 6 po a 17 8 cm a 20 3 cm 7 ou 8 po Le cas ch ant privil giez les longs r ducteurs aux r ducteurs de type plat R duisez les dimensions du conduit aussi loin de l ouverture que possible Si des courbes ou des transitions sont utilis es loignez les autant que possible de l ouverture et des autres courbes ou transitions au moment de l installation HAUTEURS DE MONTAGE ET D GAGEMENT La hauteur de montage minimale entre le dessus de la cuisini re et le dessous de hotte doit tre d au moins 61 cm 24 po La hauteur de montage maximale ne doit pas exc der 81 3 cm 32 po ll est important d installer la hotte la hauteur appropri e Une hotte trop basse peut causer des dommages par la chaleur ou des risques d in cendie tandis qu une hotte trop haute sera diffi cile atteindre et perdra de son efficacit Reportez vous aux exigences relatives la hau teur de d gagement du fabricant de la cuisini re et la hauteur de montage au dessus de la cuisini re recommand e pour la hotte Kits de rallonge disponibles pour plafonds de 3m 3 65m 10 12 D gagement minimal au plafond de 228 45 cm 89 94 po une hauteur de montage de la hotte de 61 cm 24 po D gagement maximal au plafond de 288 82 cm 113 71 po une hauteur de montage de la hotte de 81 3 cm
15. cteur de ver ES i rouillage de c ble non fourni Proc dez aux v rifications n cessaires et le cas ch ant ele les connecteurs appropri s Cab de puis installez les uit rN G INSTALLATION Ajoutez les mat riaux d assujettissement ge a AA l arriere ri Bras de support avec position des languettes Plaque d assujettissement au plafond Support ee Montage de la hotte de cuisini re 1 Placez les mat riaux d assujettissement minimum 2 morceaux de 2 x4 2 Centrez la plaque d assujettissement sur le plafond tracez un point de rep re puis fixez la a l emplacement de pose de la hotte Assurez vous que l avant du support pointe du c t indiqu dans le schema 3 Determinez la hauteur de la hotte effectuez les mesures necessaires puis fixez les quatres bras de support sur la soufflante a l aide des vis fournies utilisez les avant trous de la hotte et des bras de support Asssurez vous que les languettes situ es sur les bras de support pointent vers l ext rieur pour l avant et sur les c t s pour l arri re tel qu indiqu sur le sch ma Fixez le bras de soutient en U 4 Faite glisser les caches de conduits t lescopiques sur la partie sup rieure de la soufflante 5 Attachez le conduit au plafond et les composants l triques 6 Soulevez la soufflante Verrouillez ensuite les languettes du cadre de support dans les fentes de la plaque d assujettisment
16. la maison en employant les syst mes de conduits existants ou en installant un nouveau syst me de conduits La hotte est plus efficace en tant qu appareil d vacuation Cet appareil ne doit tre utilis comme une unit d puration que s il est impossible d en faire une unit d vacuation Lorsque vous convertissez cet appareil en unit d puration il est n cessaire de placer un ensem ble de filtres au charbon au dessus de l ensemble de filtres m talliques conventionnels Pour passer des commandes utilisez le num ro de pi ce ci dessous Les filtres m talliques sont con us pour capter les r sidus de cuisson Pour ce qui est des filtres au charbon optionnels ils aident purifier les manations cr es par la cuisson pour une recirculation de l air dans la maison Filtres au charbon requis 1 Proc dez comme suit pour acheter des filtres au charbon pour les syst mes recyclage Syst mes de conduits 1 Installez un tuyau droit de 15 2 cm 6 po et Mod le de Num ro de Filtres en un raccord en T ou un coude de 900 pour hotte pi ce paquet diriger l air dans les louvres du couvercle JXT8136ADS JFLTRC8036 3 de conduit JXT8142ADS JFLTRC8036 3 2 Retirez les filtres m talliques de la hotte Agrafez les filtres au charbon dans chaque rainure 3 R installez les filtres m talliques 4 Mettez l indicateur de remplacement des filtres du panneau en fonction A l arr t appu
17. n t approuv ou de ruban pour canalisations Quelques Options de Canalisation Pente de toit avec solin et capuchon nr capuchon mural lat ral avec registre anti refqulement TR i Soffite ou vide sanitaire INSTALLATION 5 CARACT RISTIQUES TECHNIQUES LECTRICIT AVERTISSEMENT N AVERTISSEMENT Tous les travaux lectriques doivent tre effectu s par un lectricien qualifi ou une personne pos s dant des connaissances techniques et de l exp rience similaires Pour votre s curit personnelle retirez le fusible ou coupez le disjoncteur de alimentation lectrique domestique avant de d buter l installation N utilisez pas de rallonge lectrique ou de fiches d adaptateur avec cet appareil Suivre les codes d lectricit nationaux ou les codes locaux de m me que les ordonnances en vigueur Alimentation lectrique Cet appareil n cessite une alimentation lectrique de 120 V et de 60 Hz branch e un circuit de d ri vation correctement mis la terre et prot g par un disjoncteur de 15 20 amp res ou un fusible action diff r e Le c blage doit se composer de deux fils mis la masse Veuillez galement vous reporter au diagramme lectrique pri appos sur le produit BR Verrou de c ble 4 gt Certains codes locaux peuvent galement i S exiger l utilisation d un conne
18. ormance and efficiency If available also refer to range manufacturer s height clearance requirements and recommend ed hood mounting height above range Extension kits available to accommodate 10 12 ceilings Minimum ceiling clearance 89 94 at 24 hood mounting height Maximum ceiling clearance 113 71 at 32 hood mounting height Minimum Duct Size Round 6 minimum Rectangular requires an adaptor readily available at most hardware stores Duct Run Calculation Maximum run 6 or 3 1 4 x 10 duct 100 FT Calculated Length each 90 Elbow used 15 FT each 45 elbow used 9 FT each 6 to 3 14 x 10 transition used 1 FT each 3 14 x 10 to 6 transition used 5 FT Side Wall Cap w damper 30 FT Roof Cap 30 FT e g 1 roof cap 2x90 elbows 1 45 elbow used 30 30 9 69 used 31 available for straight duct runs INSTALLATION DUCTING N WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or DuctTape Some Ducting Options Roof Pitch w Flashing amp Cap NN i side wal ji Soffit or crawl space
19. r como se muestra en el diagrama Fije los sujetadores de soporte tipo U 4 Deslice los cobertores de la tuber a telesc pica sobre la unidad de extraci n 5 Fije la tuber a de extracci n al techo y posicione el sistema el ctrico 6 Levante la unidad de extracci n y fijela a la Placa para el Techo enganche las proyecciones del marco de soporte en las ranuras de la Placa para el Techo asegure el marco de soporte a la Placa para el Techo usando los tornillos que se proporcionan 7 Conecte la tuber a y el cableado el ctrico a la unidad de extracci n deslice los cobertores de la tuber a hacia arriba para ganar acceso a la parte superior de la unidad de extracci n Sujetador de soporte tipo y Nota se deber n cortar los brazos de extensi n al ser instalados bajo un techo inferior a 3 65m 10 INSTALACION 7 INSTALACION leng etas de cierre Montando la Campana de Cocina 8 Levante la campana y enganche las proyecciones de cierre en la unidad de extracci n 9 Fije la campana al extractor con el tornillo que se propor ciona desde el interior de la campana 10 Empuje la secci n de la tuber a telesc pica hacia arriba hasta que quede en el lugar apropiado y luego fijela Nota El regulador de tiro tipo mariposa de la chimenea se puede instalar poni ndolo sobre el alojamiento del motor INSTALACION CONVERSION SIN TUBERIA DE EXTRACCION La conversi n sin t
20. ros por Campana Repuesto Paquete Tuber a de Ext E ri racci n JXT8136ADS JFLTRC8036 3 ea ee JXT8142ADS JFLTRC8036 3 1 Instale un conducto recto de 6 y un conector en T o un codo de 90 para desviar el aire a trav s de los respiraderos en la cubierta de la 2 Retire los filtros metalicos de la campana tuber a Enganche los filtros de carb n a cada apertura 3 Vuelva a instalar los filtros de metal 4 Ponga en funcion la advertencia de cambio de filtro de carb n Estando en la posici n Off desconectado presione durante aproxi madamente 5 segundos La visualizaci n cambiar de Exhaust Mode modo de extracci n a Purifying Mode Carbon Filters Used modo de purificaci n filtros de carb n en uso Esto indica que se ha activado la funci n del cron metro y que se est n usando los Filtros de Carb n 5 Los Filtros de Carb n deben ser reemplazados despu s de cada 120 horas de uso ei a Le 0 aproximadamente cada 2 6 3 meses Eh ia bas ndose en un uso promedio de 1 a 2 Eo l sanecon iriden horas por d a Cuando se activa el micro procesador en los controles este contar el i tiempo de uso y le indicar cu ndo es nece conducto recto de 6 sario cambiar los filtros de carb n Dimensiones de los filtros met licos 22 80cm 8 98 x 16 20cm 6 38 228mm x 162mm o codo de 90 amarra de pared para el conducto
21. tside of the home by employing existing or installing new duct work if possible The hood is most effective and efficient as an Exhaust unit Only when the exhaust option is not possible should you recourse to converting the hood into a purifying unit When converted to be a purifying unit a set of Carbon Filters are required on top of its standard Metal Filter set Order according to its Part number below The standard Metal Filters are intended to capture residue from cooking and the optional Carbon Filters help to purify fumes exhausted from cooking for re circulation a Carbon Filters Required 1 Purchase ductless Carbon Filters as follows ANS Hood Model Part No Filters in pkg JXT8136ADS JFLTRC8036 3 JXT8142ADS JFLTRC8036 3 2 Remove metal filters on hood Clip carbon filters onto each slot opening Re install metal filters Set filter change reminder for carbon filters When Off hold for approx 5 seconds The display will change from exhaust mode to purifying mode carbon filters used this indicates that the elapse timer function is switched on and Carbon Filter Dimensions Carbon Filters are used 8 98 in x 6 38 in 228 mm x 162 mm a Carbon Filters must be replaced after every 120 hours of use or approximately every 2 to 3 months based on the average of 1 2 hrs of daily cooking time The microprocessor in the controls when set will count usage time and
22. uber a de extracci n est hecha para situaciones en las cuales no es posible instalar una tuber a de extracci n de aire Al ser convertida la campana funciona como una campana de purificaci n en vez de una campana de extracci n Los humos y vapores producidos al cocinar son aspirados por la cam pana y filtrados por un conjunto de Filtros de Carb n opcionales El aire es entonces purificado y reciclado en el hogar Recomendamos SIEMPRE extraer el aire fuera de la casa utilizando tuber as de escape existentes o insta lando nuevas siempre que sea posible La campana es m s eficiente como una unidad de extracci n S lo cuando no es posible instalarla como un sistema de extracci n se debe usar la opci n de conversi n trans formando la campana en una unidad de purificaci n Cuando se convierte en una unidad de purificaci n se necesitan un conjunto de Filtros de Carb n adem s del conjunto de Filtros Met licos est ndar Para hacer su pedido refi rase al n mero de repuesto detallado m s adelante Los Filtros Met licos est ndar est n dise ados para capturar los residuos generados al coci nar y los Filtros de Carb n opcionales ayudan a purificar los humos que se generan al cocinar para poder as reciclar el aire dentro del hogar Filtros de Carb n Requeridos 1 Compre los Filtros de Carb n para instalaci n sin tuber a de extracci n como se detalla a continuaci n Modelo de N mero de Filt
23. yez sur pendant environ 5 secondes Lindicateur passe de mode hotte traditionelle mode recyclage filtres au charbon indiquant que la fonc tion de minuterie de temps coul est activ e et que les filtres au charbon sont utilis s 5 Les filtres au charbon doivent tre remplac s toutes les 120 heures d utilisation ou approxima tivement tous les 2 3 mois en fonction d une moyenne de temps de cuisson de 1 2 heures Une fois en fonction le microprocesseur des com mandes fait le compte du temps d utilisation et indique qu il est n cessaire de remplacer les filtres au charbon Raccord en T de 15 2 cm 6 po ou un coude de 900 Tuyau droit de LA Dimension des filtres au charbon 15 2 cm 6po i 22 80cm 8 98po x 16 20cm 6 38po0 228mmx 162mm Etrier plat pattes pour les murs CAMPANA DE COCINA N mero de Modelo JXT8136ADS JXT8142ADS N mero del Fabricante S98M90S S98E42S Tama o 35 3 8 90 cm 42 106 68 cm INSTALACION GUIA CONTENIDOS Instrucciones de Sets 1 Lista de Materiales 2 Altura de Montado 3 Tuber a de Extracci n 4 ESPEC CIONES socias 5 Instalaci n cidos 6 8 JENN AIR Form No A 04 03 Part No I59800 0303A 2004 Maytag Appliances Sales Co Litho U S A GUIA DE INSTALACION Lea todas las instrucciones antes de instalar y usar este electrodom stico MODELO
Download Pdf Manuals
Related Search
Related Contents
Installieren Sie die AGP-Grafikkarte erst, wenn Sie sich ONE INSTALLATION, LICENSING, AND VAK 100 - Bartscher GmbH Alienware Area-51 Regulation 95 Hamilton Beach 76370R User's Manual Using the USI I2C Code Library (Rev. A) Installation manual VZ-C12_2 und VZ-C32 Englisch und Targus Onyx 72 Capacity CD/DVD Case Copyright © All rights reserved.