1. HP UPS R1500 XR 1440VA 1340 Watt Low Voltage 204404 001 HP UPS R3000 XR 2880VA 2700 Watt Low Voltage 192186 001 HP UPS R3000 XR 3000VA 2700 Watt High Voltage 192186 002 Rack Mountable UPS R6000 6000VA 6000 Watt High Voltage 347207 001 NOTE The UPS R6000 has a hardwired input UPS R12000 XR N x 200 24 0V hardwired 207552 B22 NOTE The UPS R12000 XR has a hardwired input and output DA 11903 North America Version 5 May 20 2005 Page 8 QuickSpecs HP bc1000 blade PC Options UPS Options SNMP Serial Port Card 192189 B2 NOTE Supports tower and rack UPS XR models ranging from 1000 3000VA Six Port Card 192185 B21 NOTE Supports tower and rack UPS XR models ranging from 1000 3000VA High to Low Voltage Transformer 250VA 388643 B21 NOTE Supports R6000 UPS series only 2 5 amps 125 Volts max output across two NEMA 5 15 Extended Runtime Module R1500 XR 218971 B21 NOTE 2U each two ERM maximum Extended Runtime Module R3000 XR 192188 B21 NOTE 2U each one ERM maximum Extended Runtime Module R5500 XR 326564 B21 NOTE 3U each two ERM maximum Extended Runtime Module R6000 347224 B21 NOTE 3U each two ERM maximum Extended Runtime Module R1 2000 XR 4U 217800 B21 NOTE 4U each two ERM maximum R12000 XR BackPlate Receptacle Kit 2 L6 30R 325361 001 NOTE The R12000 XR BackPlate Kit has a hardwired input R12000 XR BackPlate Receptacle Kit 2 IEC 309R 325361 B21
2. Relative humidity noncondensing LEDs Top to bottom Height Width Depth Maximum Operating Non operating shipping Non operating storage Operating Non operating shipping Non operating storage Unit identification Health NIC 1 NIC 2 Drive activity Power 4 7 in 11 94 cm 0 8 in 2 03 cm 15 5 in 39 37 cm 2 2 Ib 1 0 kg 50 to 95 F 10 to 35 C 40 to 140 F 40 to 60 C 4 to 140 F 20 to 60 C 10 to 90 10 to 90 10 to 95 Off off Steady blue blade identified Blinking blue being accessed remotely Off off Green health good Amber degraded or power up prohibited by the Integrated Administrator Blinking or steady red critical Off off Green linked to network Blinking green Activity on network Off off Green linked to network Blinking green activity on network Off No drive activity Blinking green drive activity Off no AC power to blade or enclosure Amber Enclosure on and in good health Green blade power on NOTE 1 Operating temperature has an altitude derating of 34 F 1 C per 1 000 ft 304 8 m No direct sunlight Storage maximum humidity of 95 is based on a maximum temperature of 112 F 45 C Minimum pressure for storage is 70 KPa 40 GB Ultra ATA 100 Hard Drive Capacity Interface 40 GB Ultra ATA 100 Transfer rate synchronous 100 MB s maximum Seek time typical reads including s
3. 1000 W 3416 50 to 95 F 10 to 35 C 40 to 140 F 40 to 60 C 10 to 90 10 to 95 Redundant power supply utility Automatic System Recovery ASR Redundant hot plug power supplies Redundant hot plug fans NOTE 1 Operating temperature has an altitude derating of 34 F 1 C per 1 000 ft 304 8 m No direct sunlight Storage maximum humidity of 95 is based on a maximum temperature of 112 F 45 C Minimum pressure for storage is 70 KPa O invent DA 11903 North America Version 5 May 20 2005 Page 15 QuickSpecs HP bc1000 blade PC Technical Specifications Enclosure Hot Plug Power Dimensions Supply Weight Rated input Rated output Temperature Relative humidity noncondensing Dieletric voltage withstand Height Depth Width 6 5 lb 2 95 kg Voltage autosensing Frequency Current Power Maximum peak power Voltage current Power RMS Maximum peak power Operating Non operating shipping Operating Non operating Input to output Input to ground 3 579 in 9 14 cm 10 24 in 28 45 cm 4 47 in 11 43 cm 100 to 127 VAC 200 to 240 VAC 47 to 63 Hz 8 5 Aat 120 VAC 4 3 A at 240 VAC 1000 W 1167 W 5 01 V 0 5A 34A 3 33 V 0 5A 36A 12 1 V 0 5A 38A 5 Vaux 0 2A 8A 600 W 700 W for 2 minutes 5 to 55 F 10 to 35 C 40 to 85 F 40 to 60 C 10 to 90 10 to 95 2000 VAC minimum 1500 VAC minimum NOTE 1 Op
4. HP System E as well as third party and Telco racks Rack mounting hardware for HP and third party racks ships standard with each blade enclosure Telco rack mounting hardware is a separately available option kit The increasing power of new high performance processor technology requires increased cooling efficiency for rack mounted blade PCs The HP 10000 Series Racks provide enhanced airflow for maximum cooling allowing these racks to be fully loaded with blade PCs using the latest processors CAUTION If a third party rack is used observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment e Front and rear doors If your 42U rack includes closing front and rear doors you must allow 5 350 square cm 830 square inches of hole evenly distributed from top to bottom to permit adequate airflow equivalent to the required 64 percent open area for ventilation e Side The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm 2 75 inches CAUTION Always use blanking panels to fill all remaining empty front panel U spaces in the rack This arrangement ensures proper airflow Using a rack without blanking panels results in improper cooling that can lead to thermal damage NOTE Please consult the Setup amp Installation Guide for the blade PC for additional details 3U high rack mountable chassis with 20 blade PC bays Rack mounting hardwar
5. 1 HP Rack 10622 22U Shock Pallet 2451 63 B22 HP Rack 10622 22U Crated 2451 63 B23 HP Rack 10842 42U 800 mm wide Pallet 257415 B21 HP Rack 10842 42U Crated 257415 B22 NOTE B21 pallet used to ship empty racks shipped on a truck B22 shock pallet used to ship racks with equipment installed by custom systems VARs and Channels B23 crated used for air shipments of empty racks NOTE Not all HP equipment is qualified to be shipped in the Rack 10000 series NOTE Please see the Rack 10000 QuickSpecs for Technical Specifications such as height width depth weight and color p h18000 www1 hp com products quickspecs 10995 na 10995 na HTML or additional information regarding Rack Cabinets please see the following URL p h18000 www hp com products servers proliantstorage racks index html m Ti en O invent DA 11903 North America Version 5 May 20 2005 Page 10 QuickSpecs Options Rack Options for HP Rack Rack Blanking Panels Graphi 10000 Series Cable Management Rack Options for Rack 10000 Series O invent e Multi NOTE Contains one each of 1U 2U 4U and 8U Rack Blanking Panels Graphite 1U NOTE The Rack Blanking Panels Kit contains 10 each of 1U Rack Blanking Panels Graphite 2U NOTE The Rack Blanking Panels Kit contains 10 each of 2U Rack Blanking Panels Graphite 3U NOTE The Rack Blanking Pane
6. 14 B25 246107 B21 248929 B2 246099 B21 257413 B2 257414 B2 246102 B2 255486 B2 1 248931 B2 293357 B2 293358 B2 1 293359 B2 1 292407 B21 168233 B21 303606 B21 120672 B21 234672 B21 120675 B21 260457 B21 234672 B21 Page 11 QuickSpecs HP bc1000 blade PC Options Rack Options for HP Telco rack mounting hardware kit for HP e Class Blade PC Enclosure 266076 B2 Third Party and Telco Enclosure Shipping Bracket Kit 293119 B21 racks NOTE When shipping an enclosure in a rack shipping brackets must be installed to the rack NOTE For more information on rack and rack options please visit the following url http h1 8000 www hp com products servers proliantstorage rack options index html O cae ea DA 11903 North America Version 5 May 20 2005 Page 12 QuickSpecs Memory HP bc1000 blade PC HP bc1000 blade PC Standard Memory 512 MB 333 MHz DDR SDRAM 1x512 MB SODIMM installed NOTE 32 MB of system RAM is reserved for processor usage Standard Memory Plus Optional Memory Up to 1024 MB of DDR SDRAM is available with the installation of optional DDR SDRAM memory expansion kits sold separately Memory Slot 2 Standard 512 MB Empty 512 MB Maximum 1024 MB 512 MB 512 MB O TEREE DA 11903 North America Version 5 May 20 2005 Page 13 QuickSpecs HP bc1000 blade PC Technical Specifications HP bc1000 blade PC Dimensions Weight Temperature
7. Blade PC bay privileges can be set on a per user basis Virtual NMI button generates non maskable interrupt for crash debug and analysis More than 100 scriptable commands enable automated management Selective enabling of all protocols such as Telnet Logging of operating system console blade PC and enclosure hardware events user actions and invalid login attempts Administrator notification that a blade is warm Enclosure controller blade shutdown graceful Windows shutdown if blade overheats Emergency blade shutdown in the event of a critical temperature fault Enclosure Link 2 connectors reserved for future use CAUTION The enclosure link RJ 45 connectors on the interconnect tray are not to be used Connecting an external device to these enclosure link RJ 45 connecters may damage your external device For more information on the Integrated Administrator please visit the Web site at http h1 8000 www 1 hp com products servers proliant bl e class integrated admin html Service and Support HP Services provides a wide range of service offerings including a three year limited parts warranty on the HP bc1000 blade PC CAUTION Do not ship the blade PCs and enclosure while inside the rack without first installing the e Class Enclosure Shipping Bracket part number PH555A Failure to use the shipping bracket may cause damage to the blade PC and or enclosure thereby voiding the warranty The HP e Class Blade PC Enclosure has a
8. NOTE The R12000 XR BackPlate Kit has a hardwired input SNMP EN Adapter 347225 B21 NOTE Supports R6000 UPS series only Multi Server UPS Card 123508 B2 NOTE Supports R6000 UPS series only Scalable UPS Card 123509 B2 NOTE Supports R6000 UPS series only Rack Mountable PDUs HP Power Distribution Unit 16A 200 to 240V 207590 B21 1U 0U Up to 12 outlets NOTE The 16A PDU also connects to the high volt models of the UPS R3000 XR NOTE OU mounting need cable PN 340653 001 and the UPS R6000 models Cable PN 340653 001 brackets shipped with the required if connecting to UPS R3000 XR 192186 002 High Volt model only unit separate option kit HP Power Distribution Unit 40A 200 to 240V 207590 B23 ee NOTE Please see the following Power Distribution Unit Zero U 1U PDU QuickSpecs for additional options including cables http h1 8000 www1 hp com products quickspecs 10838 na 10838 na HTML O invent DA 11903 North America Version 5 May 20 2005 Page 9 QuickSpecs HP bc1000 blade PC Options Modular PDUs 1U OU Modular Power Distribution Units mPDU High Volt Model 16A 200 240 VAC 252663 B24 Up to 32 outlets NOTE This model has a detachable input power cord and is adaptable to country specitic requirements The 16A PDU also connects to the high volt models of the UPS R3000 XR and R6000 models Cable P N 340653 001 required if connecting to UPS R3000 XR 192186 002 High Volt model only Mo
9. QuickSpecs HP bc1000 blade PC Overview HP bc1000 blade PC At a Glance e 1 0 GHz Transmeta Efficeon TM8000 e 40 GB Ultra ATA 100 5400 rpm hard drive e 512 MB DDR SDRAM PC2700 333 MHz expandable to 1024 MB 2 SODIMM slots NOTE 32 MB of system RAM is reserved for processor usage e Two Broadcom 5705F 10 100 Integrated Network Controllers NIC 1 is compliant with PXE Pre boot execution Environment e Connector for graphics diagnostics card e Blade PCs protected by HP Services including a limited three year parts warranty with optional service uplifts available O invent DA 11903 North America Version 5 May 20 2005 Page 1 QuickSpecs Overview HP bc1000 blade PC Configuration Steps For a complete configuration of the HP bc1000 blade PC system you need 1 HP bc1000 blade PC sold in a single pack or 10 pack N SSS SSS N oN DO O O O sy ae y 2 HP e Class Blade PC Enclosure each can hold up to 20 blade PCs The enclosure comes bundled with 20 licenses for the ProLiant Essentials Rapid Deployment Pack cA TE DA 11903 North America Version 5 May 20 2005 Page 2 QuickSpecs HP bc1000 blade PC Standard Features HP bc1000 blade PC Processor Cache Memory Chipset Memory Network Controller Internal Storage Industry Standard Compliance Manageability High Availability Security OS Support O invent One Transmeta Effice
10. asting and quality of service QoS packet prioritization TFTP support for rapid deployment of multiple interconnect switches and to provide backup and restore capabilities Industry standard design compatible with industry standard network components from leading network manufacturers Fully pre configured for rapid deployment and immediate operation in HP e Class Blade PC Enclosure For more information on the C GbE Interconnect Switch please visit the Web site at http h1 8000 www hp com products servers proliant bl e class interconnect switch html O invent DA 11903 North America Version 5 May 20 2005 Page 5 QuickSpecs HP bc1000 blade PC Standard Features HP Integrated Administrator Features Out of band local console and remote network access to the blade enclosure and all 20 blade PCs via one RJ 45 10 100BaseT Fast Ethernet and one RS 232 management connectors Provides local and remote access to the C GbE Interconnect Switch command console Remotely power on oft reboot blade PCs and enclosures Remotely toggle on off unit identification UID LEDs of blade PCs and enclosures Monitors and controls the enclosure fans temperature sensors power supplies interconnect switch and blade PC status Connect to each blade PC s serial text console for enabling full control over blade PC s Power On Self Test POST and boot process including the ROM Based Setup Utility RBSU User administration for up to 25 users
11. dular Power Distribution Units mPDU High Volt Model 24A 200 240 VAC 252663 D72 Modular Power Distribution Units mPDU Low Volt Model 24A 100 127 VAC 252663 D71 Modular Power Distribution Units mPDU High Volt Model 40A 200 240 VAC 252663 B21 NOTE This mPDU 252663 B21 40A model has a hardwired input NOTE Please see the following Modular Power Distribution Unit Zero U 1U Modular PDUs QuickSpecs for additional options including shorter jumper cables and country specific power cords http h1 8000 www1 hp com products quickspecs 11041 na 11041_ na HTML PDU Options Third Party PDU Mounting Kit 310777 B21 NOTE This kit allows you to mount the Modular PDUs in racks other than the 9000 10000 Series racks any racks using the standard 19 rail For more details please refer the Modular PDU QuickSpecs Enterprise Configurator Please see the CO for configuration assistance at http www hp com products contigurator HP Rack 10000 Series S 10614 14U Rack Cabinet Shock Pallet 292302 B22 Graphite Metallic HP Rack 10647 47U Pallet 245160 B21 HP Rack 10647 47U Crated 2451 60 B23 HP Rack 10642 42U Pallet 245161 B21 HP Rack 10642 42U Shock Pallet 245161 B22 HP Rack 10642 42U Crated 245161 B23 HP Rack 10636 36U Pallet 245162 B21 HP Rack 10636 36U Shock Pallet 245162 B22 HP Rack 10636 36U Crated 2451 62 B23 HP Rack 10622 22U Pallet 245163 B2
12. e for HP Compaq branded and third party racks Rear bay for Interconnect Switch for network cable management Two 2 Diagnostic Adapters see features following for connecting keyboard video mouse and other devices locally to individual blade PCs ProLiant Essentials Foundation Pack licenses for 20 Blade PCs see features following includes the HP Systems Insight Manager and ProLiant Essentials Rapid Deployment Pack CD Four hot plug fans Dual hot plug power supplies 600 watts each power cords Blade PC blanks to fill 19 of the 20 blade PC bays Null modem cable for serial connection to the Integrated Administrator serial Console connector HP Documentation CD NOTE Two Diagnostic Adapters are included with every enclosure Blade PC LEDs 6 PS 2 Mouse PS 2 Keyboard VGA monitor functional only when graphics diagnostics card installed Serial RS 232 port USB 1 1 ports 2 DA 11903 North America Version 5 May 20 2005 Page 4 QuickSpecs HP bc1000 blade PC Standard Features ProLiant Essentials HP Systems Insight Systems Insight Manager helps maximize system uptime and performance Foundation Pack Software Manager and reduces the cost of maintaining the IT infrastructure by providing proactive notification of problems before those problems result in costly downtime and reduced productivity Insight Manager is easy to set up and provides rapid access to inventory information http www hp com go hpsim P
13. erating temperature has an altitude derating of 34 F 1 C per 1 000 ft 304 8 m No direct sunlight Storage maximum humidity of 95 is based on a maximum temperature of 112 F 45 C Minimum pressure for storage is 70 KPa C GbE Interconnect General Switch Performance Forwarding mode MAC addresses Memory O invent DA 11903 Two 24 port Managed Layer 2 Ethernet switches for network cable reduction fully pre configured for immediate operation 4 0 Gbps Switching bandwidth 12 million pps aggregate throughput 64 byte packets Full wire speed for all connections Store and forward 16 382 MAC address based filtering and MAC address packet priority configuring 64 MB Main 12 MB Flash 32 MB Packet Buffer North America Version 5 May 20 2005 Page 16 QuickSpecs HP bc1000 blade PC Technical Specifications O invent Ports Management High availability Security IEEE standards compliance Form factor DA 11903 Four RJ 45 10 100 1000 T TX T Gigabit Ethernet uplink ports for customer use Forty 10 100 T TX fast Ethernet downlink ports dedicated to blade PC to interconnect switch network connections Two 10 100 T TX Fast Ethernet ports dedicated to inter switch module communications One RS 232 DB 9 port console connector for Integrated Administrator One 10 100 T TX Fast Ethernet port Network management connector for Integrated Administrator Auto nego
14. ettling Rotational speed O invent DA 11903 Single track Average Maximum 5400 rpm North America Version 5 May 20 2005 1 5 ms 12 ms 22 ms Page 14 QuickSpecs HP bc1000 blade PC Technical Specifications Broadcom 5705F 10 100 Network interface Integrated NIC Enclosure Compatibility Data transfer method Features Network transfer rate Connector Cable support Dimensions Weight with interconnect tray 10Base T 1 OOBase TX IEEE 802 3 802 3u compliant 32 bit bus master PCI NIC 1 WOL enabled and PXE compliant 10Base T halt duplex 10Base T full duplex 100Base TX half duplex 100Base TX full duplex 10 Mb s 20 Mb s 100 Mb s 200 Mb s Mates into enclosure center wall assembly 10Base T 00Base TX Height 3U Width Depth No blade PCs 20 blade PCs Rated input autosensing Voltage BTUs Temperature Relative humidity noncondensing Management High availability Frequency Current Power Per hour Operating Shipping 72 hours Operating Non operating Enclosure self recovery Health logs Categories 3 5 or 6 UTP up to 328 ft 100 m Category 5 or 6 UTP up to 328 ft 100 m 5 25 in 13 34 cm 19 in 48 26 cm 27 in 68 58 cm 59 b 26 76 kg 103 Ib 46 7 kg Minimum 90 VAC Maximum 264 VAC Nominal 100 to 120 VAC or 200 to 240 VAC 47 to 63 Hz 11 7 A at 90 VAC 8 5 A at 120 VAC 4 3 A at 240 VAC
15. fficeon TM8000 1024K L2 512 MB DDR SDRAM PC2700 333 MHz Two Broadcom 5705F 10 100 Integrated NICs 40 GB Ultra ATA 100 5400 rpm Plugs vertically into HP e Class Blade PC Enclosure North America Version 5 May 20 2005 Page 7 QuickSpecs HP bc1000 blade PC Options Enclosure and Switch Memory Miscellaneous UPS and PDU Power Cord Matrix Uninterruptible Power Systems Rack O invent HP e Class Blade PC Enclosure includes 20 licenses for ProLiant Essentials Rapid DW366A Deployment Pack at 50 of the standard per node license list price Enclosure Shipping Bracket Kit NOTE When shipping an enclosure in a rack shipping brackets must be installed to the rack C GbE Interconnect Switch includes Integrated Administrator module DW367A 512 MB DDR SDRAM PC2700 333 MHz Option Kit 1 x 512 MB PA715A PS 2 Mouse DD440B PS 2 Keyboard DT527A TFT5600 Rackmount Keyboard and Monitor 221546 001 TFT721OR 17 inch Rackmount Monitor 348373 B21 Integrated Keyboard and Drawer 257054 001 External USB MultiBay Caddy DC373A ABA Third party Rail Kit for HP Input Devices 287139 B21 Telco Rail Kit for HP Input Devices 287138 B21 MultiBay 24X CD ROM 217396 930 Graphics Diagnostics Card 5 pack DV300C Please see the UPS and PDU cable matrix that lists cable descriptions requirements and specitications for UPS and PDU units ttp ttp compaq com pub products servers ProLiantstorage power protection powercordmatrix pdf
16. ls Kit contains 10 each of 3U Rack Blanking Panels Graphite 4U NOTE The Rack Blanking Panels Kit contains 10 each of 4U Rack Blanking Panels Graphite 5U NOTE The Rack Blanking Panels Kit contains 10 each of 5U 600mm Stabilizer Kit Graphite Baying Kit for Rack 10000 series Carbon 42U Side Panel Graphite Metallic 110V Fan Kit Graphite NOTE Roof Mount Includes power cord with IEC320 C13 to Nema 5 15P 220V Fan Kit Graphite NOTE Roof Mount Includes power cord with IEC320 C13 to Nema 6 15P 36U Side Panel Graphite Metallic 47U Side Panel Graphite Metallic 9000 10000 Series Offset Baying Kit 42U NOTE This kit can be used to connect 9000 and 10000 series racks of the same U height together Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of the two racks FC Cable Routing Spool box of 12 Rail to Rail FC Cable Routing Side Rail FC Routing box of 6 Compaq Networking Cable Management Kit Cable Management D Rings Kit Monitor Utility Shelf Ballast Option Kit 100kg Sliding Shelf Rack Rail Adapter Kit 25 depth 9000 10000 Grounding Kit 100 kg Shelf Kit NOTE This 100Kg Shelf Kit PN 234672 B21 supports the Rack 10000 and 9000 series only DA 11903 North America Version 5 May 20 2005 HP bc1000 blade PC 253214 B26 253214 B2 2532 14 B22 253214 B23 253214 B24 2532
17. on TM8000 1 0 GHz processor integrated North Bridge with 400 MHz Hyper Transport South Bridge interface 1024K L2 ALi M1563M South Bridge NOTE For more information regarding Acer Labs Inc please see the following URL http www ali com tw Standard 512 MB DDR SDRAM PC2700 333 MHz 1x512 MB SODIMM NOTE 32 MB of system RAM is reserved for processor usage Maximum 1024 MB 2 SODIMM slots total Two 5705F 10 100 Integrated Network Controllers NIC lis compliant with PXE One 40 GB Ultra ATA 100 5400 rpm hard drive ACPI 1 0b ANSI C63 4 1992 C LS P R Pub 22 CFR 47 Part 15 EN 55022 EN 55024 EN 60950 2000 ICES 003 IEC 61000 4 Section 2 6 8 11 IEC 730 1 IEC 801 Part 2 IPC A 610 PC2700 PCI 2 3 PXE 2 1 SPD 1 2B UL 94 UL 796 USB 1 1 HP Systems Insight Manager ROM Based Setup Utility RBSU Automatic System Recovery ASR System Software Manager SSM DOS based replicated setup utility REPSET Unit ID LED Robust boot block recovery ROM F5 auto roll over to new blade Dual network communication paths Administrator s password Microsoft Windows XP Pro with Service Pack la DA 11903 North America Version 5 May 20 2005 Page 3 QuickSpecs HP bc1000 blade PC Standard Features HP e Class Blade PC Enclosure sold separately Rack Capability Rack Airflow Requirements Enclosure includes Diagnostic Adapter Interfaces O invent Mounts in HP 10000 and 9000 series
18. roLiant Essentials Rapid An automated solution for deployment and provisioning enabling Deployment Pack companies to quickly and easily adapt to changing business demands NOTE For more information regarding ProLiant Essentials Software please see the following URL http www hp com servers proliantessentials Interconnect Switch Full featured web based interface menu driven console interface SNMP Management System and based scripting utility and example scripts SNMP and RMON MIBs and Utilities TFTP utilities for management of interconnect switch C GbE Interconnect Switch Features sold separately Provides up to a 40 to 1 reduction in network cables for each blade enclosure using a pair of non blocking layer 2 switch modules Four RJ 45 10 100 1000T Gigabit Ethernet uplinks Forty 10 100T Ethernet ports dedicated to blade to interconnect switch network communications Communicate with all 40 blade PC network controllers through any one uplink connector and the management connector Includes Integrated Administrator module see features following Spanning tree protocol for loop free path redundancy Browser scriptable CLI and console based interfaces for local and remote interconnect switch management Manage entire interconnect switch through the Integrated Administrator connectors or any uplink connector Telnet RMON and SNMP support SNMP based scripting utility with example scripts IGMP internet group management protocol multic
19. three year limited warranty on parts labor and on site support Warranties are fully supported by a network of resellers and service providers in over 160 countries HP warranty assistance is available 7x24 toll free in the United States and Canada Other additional support services may be covered under warranty or available for an additional fee A full range of HP Care Pack packaged hardware and software services Add labor or on site service for the blade PC Installation and start up Extended coverage hours and enhanced response times System management and performance services Availability and recovery services NOTE For more information customer resellers can contact http www hp com services carepack NOTE Certain restrictions and exclusions apply Consult the Customer Support Center at 1 800 567 1616 for details O invent DA 11903 North America Version 5 May 20 2005 Page 6 QuickSpecs HP bc1000 blade PC Models bc1000 blade PC DS658A 1 pack bc1000 blade PC DS659A 10 pack O invent Processor Cache Memory Memory Network Controller Hard Drive Form Factor Processor Cache Memory Memory Network Controller Hard Drive Form Factor DA 11903 1 0 GHz Transmeta Efficeon TM8000 1024K L2 512 MB DDR SDRAM PC2700 333 MHz Two Broadcom 5705F 10 100 Integrated NICs 40 GB Ultra ATA 100 5400 rpm Plugs vertically into HP e Class Blade PC Enclosure 1 0 GHz Transmeta E
20. tiation and auto sensing with full duplex Web based interface with graphical user interface Console menu driven Interface via local RS 232 and Telnet Scriptable command line interface CLI SNMP v1 RFC 1157 with scripting tool and example scripts RMON v1 RFC 1757 groups 1 2 3 and 9 Telnet RFC 854 MIB II RFC 1213 Bridge MIB RFC 1493 Interface MIB RFC 2233 801 1Q MIB RFC 2684 RMON MIB RFC 1757 groups 1 2 3 and 9 Ethernet MIB RFC1643 and HP specific switch MIBs XML human read write configuration file TFTP client RFC 783 for backup and remote download of configuration and history log files IGMP Internet Group Management Protocol multicasting Uplink port speed and link activity LEDs Simple network time protocol SNTP Broadcast multicast and DA unknown packet storm control BootP and DHCP client support Port mirroring HP Interconnect Switch Management System and Utilities Dual network communication paths using redundant non blocking layer 2 switch modules with redundant inter module communication links Two redundant uplink ports per each interconnect switch module Spanning tree protocol for loop free path redundancy Multilevel user names and passwords with configurable time out period setting IP address restriction EEE 802 3 10Base T Ethernet EEE 802 3u 100Base TX Ethernet EEE 802 3ab 1000Base T Ethernet EEE 802 1D Spanning Tree Protocol EEE 802 1p Quality of Service QoS Packet Prioriti
21. zation EEE 802 3x Flow Control Removable interconnect tray that plugs into the rear of the server blade enclosure North America Version 5 May 20 2005 Page 17 QuickSpecs HP bc1000 blade PC Technical Specifications Network transfer rate 10Base T halt duplex 10 Mb s 10Base T full duplex 20 Mb s 100Base TX half duplex 100 Mb s 100Base TX full duplex 200 Mb s 1000Base T full duplex 2000 Mb s uplink ports only Cable support 10Base T Categories 3 5 or 6 UTP up to 328 ft 100 m 00Base TX Category 5 or 6 UTP up to 328 ft 100 m 1000Base T uplink ports Category 5 or 6 UTP up to 328 ft 100 m only Copyright 2005 Hewlett Packard Development Company L P The information contained herein is subject to change without notice Microsoft and Windows NT are US registered trademarks of Microsoft Corporation The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein O invent DA 11903 North America Version 5 May 20 2005 Page 18