Hotpoint HTDP120GDWW Installation Instructions
Contents
1. 11 MOBILE OR MANUFACTURED HOME INSTALLATION e Installation must conform to the MANUFACTURED HOME CONSTRUCTION amp SAFETY STANDARD TITLE 24 PART 32 80 or when such standard is not applicable with AMERICAN NATIONAL STANDARD FOR MOBILE HOME NO 5018 e The dryer MUST be vented to the outdoors with the termination securely fastened to the mobile home structure See EXHAUST INFORMATION section 6 The vent MUST NOT be terminated beneath a mobile or manufactured home The vent duct material MUST BE METAL KIT 14 D346 33 MUST be used to attach the dryer securely to the structure The vent MUST NOT be connected to any other duct vent or chimney Do not use sheet metal screws or other refastening devices which extend into the interior of the exhaust vent Provide an opening with a free area of at least 25 sq in or introduction of outside air into the dryer room Stacking of a gas dryer is not permitted in a mobile home or manufactured home Installation Instructions 12GARAGE INSTALLATION IF ALLOWED ADDING NEW DUCT BY LOCAL CODES e Dryers installed in garages must be elevated 18 inches 46cm above the floor PORTION A 13 DRYER EXHAUST TO RIGHT LEFT OR BOTTOM CABINET A WARNING BEFOREPERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE DRYER FROM ITS LEFT SIDE ELECTRICAL SUPPLY PROTECT YOUR Reconnect the cut Sera A of the duct to the blower HANDS AND ARMS FROM SHARP hous
2. and repeat the soap test Installation Instructions ELECTRICAL CONNECTION INFORMATION A WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK AND PERSONAL INJURY e DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE Dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes in accordance with the NATIONAL ELECTRICAL CODE ANSI NFPA NO 70 ELECTRICAL REQUIREMENTS This appliance must be supplied with 120V 60Hz and connected to a properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time delay fuse If electrical supply provided does not meet the above specifications it is recommended that a licensed electrician install an approved outlet EXHAUST INFORMATION A WARNING IN CANADA AND IN THE UNITED STATES THE REQUIRED EXHAUST DUCT DIAMETER IS 4 IN 102mm DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE Using exhaust longer than specified length will e Increase the drying times and the energy cost e Reduce the dryer life e Accumulate lint creating a potential fire hazard The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not covered by the warranty Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct The MAXIMUM ALLOWABLE duct length and number of bends
3. the short hose onto the washer fill valve connector Tighten by hand until firmly seated 3 Attach the female end of the Y connector to the male coupling of the short hose Ensure the rubber flat washer is in place Tighten by hand until firmly seated 4 Insert the filter screen in the coupling of the washer s inlet hose If a rubber flat washer is already in place remove it before installing the filter screen Attach this coupling to one male end of the Y connector Tighten by hand until firmly seated 5 Ensure the rubber flat washer is in place and attach the dryer s long inlet hose to the other male end of the Y connector Tighten by hand until firmly seated 6 Ensure the rubber flat washer is in place and attach the other end of the dryer s long inlet hose to the fill valve connector at the bottom of the dryer back panel Tighten by hand until firmly seated 7 Using pliers tighten all the couplings with an additional two thirds turn NOTE Do not overtighten Damage to the couplings may result 15 CONNECTING INLET HOSES cont 8 Turn the water faucet on 9 Check for leaks around the Y connector faucet and hose couplings WATER SUPPLY REQUIREMENTS Hot and cold water faucets MUST be installed within 42 in 107 cm of your washer s water inlet The faucets MUST be 3 4 in 1 9 cm garden hose type so inlet hoses can be connected Water pressure MUST be b
4. your washer This will allow better access when installing dryer exhaust DISCONNECTING GAS TURN GAS SHUT OFF VALVE TO THE OFF POSITION DISCONNECT AND DISCARD OLD FLEXIBLE GAS CONNECTOR AND OLD TRANSITION DUCTING MATERIAL REPLACE WITH NEW CSA AGA APPROVED FLEXIBLE GAS LINE CONNECTOR AND UL APPROVED TRANSITION DUCT A WARNING never REUSE OLD FLEXIBLE CONNECTORS The use of old flexible connectors can cause leaks and personal injury Always use new flexible connectors when installing gas appliances REMOVING LINT FROM WALL EXHAUST OPENING e Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct INTERNAL DUCT CHECK THAT EXHAUST OPENING HOOD DAMPER OPENS AND CLOSES FREELY TILT THE DRYER SIDEWAYS AND REMOVE THE FOAM SHIPPING PADS BY PULLING AT THE SIDES AND BREAKING THEM AWAY FROM THE DRYER LEGS BE SURE TO REMOVE ALL OF THE FOAM PIECES AROUND THE LEGS 2 GAS REQUIREMENTS AWARNING Installation must conform to local codes and ordinances or in their absence the NATIONAL FUEL GAS CODE ANSI 2223 e This gas dryer is equipped with a Valve Burner Assembly for use only with natural gas Using conversion kit WE25X0217 your local service organization can convert this dryer for use with propane LP gas ALL CONVERSIONS MUST BE MADE BY PROPERLY TRAINED AND QUALIFIED PERSONNEL AND IN ACCORDANCE WITH LOCAL CODES AND ORDINANCE R
5. EQUIREMENTS e The dryer must be disconnected from the gas supply piping system during any pressure testing of that system at a test pressure in excess of 0 5 PSI 3 4 KPa e The dryer must be isolated from the gas supply piping system by closing the equipment shut off valve during any pressure testing of the gas supply piping of test pressure equal to or less than 0 5 PSI 3 4 KPa DRYER GAS SUPPLY CONNECTION 3 8 NPT MALE THREAD GAS SUPPLY OTE Add to vertical dimension he distance between cabinet bottom to floor GAS SUPPLY e A 1 8 in National Pipe Taper thread plugged tapping accessible for test gauge connection must be installed immediately upstream of the gas supply connection to the dryer Contact your local gas utility should you have questions on the installation of the plugged tapping Supply line is to be 1 2 in rigid pipe and equipped with an accessible shut off within 6 ft of and in the same room with the dryer Use pipe thread sealer compound or Teflon tape appropriate for natural or LP gas You must use with this dryer a flexible metal connector listed connector ANSI 221 24 CSA 6 10 The length of the connect shall not exceed 3 ft Connect flexible metal connector to dryer and gas supply Open shut off valve ADJUSTING FOR ELEVATION e Gas clothes dryers input ratings are based on sea level operation and need not be adjusted for operation at or below 2000 ft elevati
6. For best performance separate all turns by at least 4 ft of straight duct including distance between last turn and exhaust hood TURNS OTHER THAN 90 e One turn of 45 or less may be ignored e Two 45 turns should be treated as one 90 turn e Each turn over 45 should be treated as one 90 turn SEALING OF JOINTS All joints should be tight to avoid leaks The male end of each secti of duct must point away from the dryer Do not assemble the ductwork with fasteners that extend into duct They will serve as a collection point for lint Duct joints can be made air and moisture tight by wrapping overlapped joints with duct tape eHorizontal runs should slope down toward the outdoors 1 4 inch per foot INSULATION Duct work that runs through an unheated area or is near air ln should be insulated to reduce condensation and lint uild up ENSURE PROPER GROUND EXISTS BEFORE USE IF LOCAL CODES PERMIT AN EXTERNAL GROUND WIRE NOT PROVIDED WHICH MEETS LOCAL CODES MAY BE ADDED BY ATTACHING TO THE GREEN GROUND SCREW ON THE REAR OF THE DRYER AND TO A GROUNDED METAL COLD WATER PIPE OR OTHER ESTABLISHED GROUND Installation Instructions EXHAUST CONNECTION STANDARD REAR EXHAUST Vented above floor level A WARNING TO REDUCE THE a RISK OF FIRE OR PERSONAL INJURY e This clothes dryer must be exhausted to the outdoors We recommend that you install your dryer before installing your washe
7. Installation Instructions Gas Dryer 01 Questions Call 800 GE CARES 800 432 2737 or visit our Web site at GEAppliances com In Canada call 1 800 561 3344 or visit www GEAppliances ca BEFORE YOU BEGIN Read these instructions completely and carefully e IMPORTANT Save these instructions for local inspector s use e IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the customer Note to Customer Keep these instructions with your Owner s Manual for future reference Before the old dryer is removed from service or discarded remove the dryer door Inspect the dryer exhaust outlet and straighten the outlet walls if they are bent Service information and the wiring diagram are located in the control console Do notallow children on or in the appliance Close supervision of children is necessary when the appliance is used near children Install the dryer where the temperature is above 50 F for satisfactory operation of the dryer control system Product failure due to improper installation is not covered under the Warranty A WARNING risk or FIRE eTo reduce the risk of severe injury or death follow all installation instructions Clothes dryer installation must be performed by a qualified installer eInstall the clothes dryer according to these instructions and in accordance with local codes In the absence of local codes installation must comply wi
8. Keep the duct as straight as possible for maximum airflow 4 Secure the duct to the exhaust pipe with the other clamp ELBOW HIGHLY RECOMMENDED iy N RECOMMENDED IE SITDRYER ON FLEXIBLE EXHAUST DO NOT USE EXCESSIVE EXHAUST LENGTH FLEXIBLE EXHAUST 9 ALCOVE OR CLOSET INSTALLATION If your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back The dryer MUST be vented to the outdoors See the EXHAUST INFORMATION section Minimum clearance between dryer cabinet and adjacent walls or other surfaces is 0 in either side 3 in front and rear Minimum vertical space from floor to overhead cabinets ceiling etc is 52 in Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line No other fuel burning appliance shall be installed in the same closet with the dryer 10 BATHROOM OR BEDROOM INSTALLATION e The dryer MUST be vented to the outdoors See EXHAUST INFORMATION section 6 e The installation must conform with local codes or in the absence of local codes with the NATIONAL FUEL GAS CODE ANSI 2223
9. ese instructions Installers Be sure to leave these instructions with the customer In the state of Massachusetts e Installation must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the state e When using ball type gas shut off valves they shall be T handle type e A flexible gas connector when used must not exceed 3 feet EE gt MATERIALS YOU WILL NEED a OE 4 DIA METAL DUCT RECOMMENDED DDD 4 DIA FLEXIBLE METAL SEMI RIGID 10 ADJUSTABLE WRENCHES LLISTED E METAL GF DUCT E ra U x2 IF NEEDED aA SS KIT WX08X10077 INCLUDES 2 ELBOWS 4 DUCT CLAMPS o a i E Mw OR YY 4 SPRING CLAMPS Qu PIPE 4 DIAM METAL ELBOW EXHAUST HOOD COMPOUND SOAP SOLUTION FOR LEAK DETECTION I SAFETY GLASSES COM E Do E D FLEXIBLE GAS LINE CONNECTOR GLOVES 234D2217P001 31 1673535 10 13 GE DUCT TAPE 8 PIPE WRENCH LEVEL CG gt ia IEA 4 DIA FLEXIBLE METAL FOIL TYPE N UL LISTED TRANSITION DUCT SLIP JOINT PLIERS FLAT BLADE SCREWDRIVER IF NEEDED Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are O in clearance both sides and 1 in rear Consideration must be given to provide adequate clearance for installation and service LIPREPARING FOR INSTALLATION OF NEW DRYER TIP Install your dryer before installing
10. etween 10 and 120 pounds per square inch Your water department can advise you of your water pressure NOTE A water softener is recommended to reduce buildup of scale inside the steam generator if the home water supply is very hard 16 SERVICING A WARNING LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION AFTER SERVICING INSTALLATION For servicing phone numbers for replacement parts and other information refer to Owner s Manual or visit our Web site REGISTER YOUR NEW APPLIANCE TO RECEIVE ANY IMPORTANT PRODUCT NOTIFICATIONS Please go to www GEAppliances com or mail in your Product Registration Card For questions on installation call 800 626 2000 US or 800 561 3344 Canada Notes Notes Notes
11. her enclosed spaces Total length of flexible metal duct should not exceed 8 feet 2 4m For many applications installing elbows at both the dryer and the wall is highly recommended see illustrations below Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct maximizing drying performance Avoid resting the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect the dryer to the house vent using a flexible metal foiltype duct A UL listed flexible metal foil type duct may be used ONLY in installations where rigid metal or flexible metal semi rigid ducting cannot be used AND where a 4 diameter can be maintained throughout the entire length of the transition duct In Canada and the United States only the flexible metal foil type ducts that comply with the Outline for Clothes Dryer Transition Duct Subject 2158A shall be used Never install flexible metal duct in walls ceilings floors or other enclosed spaces Total length of flexible metal duct should not exceed 8 feet 2 4m Avoid resting the duct on sharp objects For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap the exhaust pipe Cut off and remove excess duct
12. ing Make sure that the shortened duct is aligned with EDGES WHEN WORKING INSIDE THE the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base CABINET BE SURE TO WEAR GLOVES ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT SIDE OF CABINET e Preassemble 4 elbow with 4 duct Wrap duct tape around joint REMOVE Pe e Insert duct assembly elbow first through the side SCREW opening and connect the elbow to the dryer internal duct yO A CAUTION Be sure not to pull or damage 2 the electrical wires inside the dryer when inserting the DESIRED KNOCKOUT ONE ONLY Detach and remove the bottom right or left side knockout as desired Remove the screw inside the dryer exhaust duct and save Pull the duct out of the dryer EXHAUST CAN Note Only 4 round rigid metal ducting allowed inside IEF OR RIGHT SDE FIXING HOLE Cut the duct as shown and keep portion A TAB LOCATION e Apply duct tape as shown on the joint between the dryer internal duct and the elbow BEND TAB UP 45 4 O y ae CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause o a safety hazard Through the rear opening locate the tab in the middle of the appliance base Lift the tab to about 45 using a flat blade screwdriver Installation Instructions ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET e Insert the elbow through
13. m the hinge side of the dryer by removing its two screws Remove the strike plate from the opposite side of the E O y STRIKE BLIND dryer by removing its two Plate PLATE screws Reinstall the plates Nenn on the opposite sides using AO f two screws in each plate Rotate the door 180 Insert the door on the opposite side of the opening by moving the door ON and DOWN until the top hinge and the bottom hinge are resting on the top screws inserted in step 1 ROTATE DOOR 180 AND HANG IT ON TOP HINGE SCREWS Remove the remaining screws from the side of the opening from which the door was removed With these screws secure each hinge at the bottom Tighten the two top screws on each hinge Reinsert the plastic plugs on the side from which the door was removed INSTALL AND TIGHTEN BOTTOM SCREWS AND TIGHTEN TOP INSERT PLUGS INTO HOLES ON OPPOSITE SIDE Installation Instructions 15 CONNECTING INLET HOSES on some models To produce steam the dryer must connect to the cold water supply Since the washer must also connect to the cold water a Y connector is inserted to allow both inlet hoses to make that connection at the same time NOTE Use the new inlet hoses provided never use old hoses 1 Turn the cold water faucet off Remove the washer inlet hose from the washer fill valve connector cold 2 Ensure the rubber flat washer is in place and screw the female coupling of
14. of the exhaust system especially at turns and joints Exhaust system shall be inspected and cleaned at least once year THIS DRYER COMES READY FOR REAR EXHAUSTING IF SPACE IS LIMITED USE THE INSTRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET STANDARD REAR EXHAUST Vented at floor level FOR STRAIGHT LINE INSTALLATION CONNECT THE DRYER EXHAUST TO THE EXTERNAL EXHAUST HOOD USING DUCT TAPE OR CLAMP CSA AGA APPROVED NEW FLEXIBLE GAS LINE CONNECTOR area S 4 LEVELING LEGS DUCT opening PPE STAND THE DRYER UPRIGHT NEAR THE M N N FINAL LOCATION AND ADJUST THE 4 LEVELING LEGS TO MATCH THE HEIGHT OF YOUR WASHER 2 ANTI TIP LEGS ADJUST THE 2 ANTI TIP LEGS TO CONTACT DUCT TAPE OR Pa THE FLOOR DUCT CLAMP j 4 METAL DUCT CUT TO PROPER LENGTH DUCT TAPE OR DUCT CLAMP NOTE WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING HOWEVER IF FLEXIBLE DUCTING IS USED IT MUST BE UL LISTED METAL NOT PLASTIC Installation Instructions CONNECTING THE DRYER TO HOUSE VENT RIGID METAL TRANSITION DUCT e For best drying performance a rigid metal transition duct is recommended e Rigid metal transitions ducts reduce the risk of crushing and kinking UL LISTED FLEXIBLE METAL SEMI RIGID TRANSITION DUCT If rigid metal duct cannot be used then UL listed flexible metal semi rigid ducting can be used Kit WX08X10077 Never install flexible metal duct in walls ceilings floors or ot
15. of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below The maximum duct length for rigid metal duct is shown in the table below EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types run installations A WARNING THIS DRYER IS EQUIPPED A THREE PRONG GROUNDING x PLUG FOR YOUR PROTECTION AGAINST ENN Matal Elbows Metal Metal SHOCK HAZARD AND SHOULD BE PLUGGED 90 Feet 60 Feet 60 Feet 45 Feet DIRECTLY INTO A PROPERLY GROUNDED 35 Feet 25 Feet THREE PRONG RECEPTACLE DO NOT CUT e For every extra 90 elbow reduce the allowable vent system OR REMOVE THE GROUNDING PRONG length by 10 ft FROM THIS PLUG e Two 45 elbows will be treated like one 90 elbow e For the side exhaust installations add one 90 elbow to the chart e The total vent system length includes all the straight portions and elbows of the system transition duct included EXHAUST SYSTEM CHECK LIST HOOD OR WALL CAP Terminate in a manner to prevent back drafts or entry of birds or other wildlife Termination should present minimal resistance to the exhaust air flow and should require little or no maintenance to prevent clogging e Never install a screen in or over the exhaust duct This could cause lint build up eWall caps must be installed at least 12 in above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS
16. on For operation at elevations above 2000 ft input ratings should be reduced at a rate of 4 percent for each 1000 ft above sea level e Installation must conform to local codes and ordinances or in their absence the NATIONAL FUEL GAS CODE ANSI 2223 Installation Instructions 3 RECONNECTING GAS Listed connector ANSI Z21 24 CSA 6 10 APPLY PIPE COMPOUND ADAPTER TO ALL MALE THREADS 1 8 NPT PIPE PLUG FOR NEW METAL CHECKING GAS FLEXIBLE GAS gt I LINE CONNECTOR gt INLET PRESSURE SHUT OFF ADAPTER VALVE PIPE SIZE ITEMS NOT SUPPLIED AT LEAST 1 2 Note The connector and fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location Keep flare end of adaptor free of grease oil and thread sealant CAUTION Use adapters as shown Connector nuts must not be connected directly to pipe threads TIGHTEN ALL CONNECTIONS USING TWO ADJUSTABLE WRENCHES DO NOT OVERTORQUE GAS CONNECTIONS LEAK TEST A WARNING never USE AN OPEN FLAME TO TEST FOR GAS LEAKS APPLY PIPE COMPOUND TO THE ADAPTER AND DRYER GAS INLET AS VALVE TIGHTEN THE FLEXIBLE GAS LINE USING TWO ADJUSTABLE WRENCHES MS ck all connections for leaks with soapy solution or equivalent ly soap solution Leak test solution must not contain ammonia ch could cause damage to the brass fittings If leaks are found se valve retighten the joint
17. r This will permit direct access for easier exhaust connection all Use only 4 rigid metal ducting forthe home exhaust CONFIGURATION duct TO MINIMIZE Use only 4 rigid metal or UL listed flexible metal EXHAUST semi rigid or foil type duct to connect the dryer BLOCKAGE to the home exhaust duct It must be installed in accordance with the instructions found in Connecting The Dryer To House Vent on page 6 of this manual ELBOW HIGHLY Do not terminate exhaust in a chimney a wall RECOMMENDED a ceiling gas vent crawl space attic under an enclosed floor or in any other concealed space of a building The accumulated lint could create a potential fire hazard NOTE ELBOWS WILL PREVENT DUCT Never terminate the exhaust into a common duct KINKING AND COLLAPSING with a kitchen exhaust system A combination of grease and lint creates a potential fire hazard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint LEVELING DRYER creating a potential fire hazard Never install a screen in or over the exhaust duct LEVEL This will cause lint to accumulate creating a FRONT TO BACK potential fire hazard LEVEL Do not assemble ductwork with any fasteners SIDE TO SIDE that extend into the duct These fasteners can accumulate lint creating a potential fire hazard Do not obstruct incoming or exhausted air Provide an access for inspection and cleaning
18. th National Fuel Gas Code ANSIZ223 1 NFPA 54 or the Canadian Natural Gas and Propane Installation Code CSA B149 1 California Safe Drinking Water and Toxic Enforcement Act This act requires the governor of California to publish a list of substances known to the state to cause cancer birth defects or other reproductive harm and requires businesses to warn customers of potential exposure to such substances Gas appliances can cause minor exposure to four of these substances namely benzene carbon monoxide formaldehyde and soot caused primarily by the incomplete combustion of natural gas or LP fuels Properly adjusted dryers will minimize incomplete combustion Exposure to these substances can be minimized further by properly venting the dryer to the outdoors This dryer must be exhausted to the outdoors e Use only 4 rigid metal ducting for exhausting the clothes dryer to the outdoors DO NOT install a clothes dryer with flexible plastic ducting materials If flexible metal semi rigid or foil type duct is installed it must be UL listed and installed in accordance with the instructions found in Connecting The Dryer To House Vent on page 6 of this manual Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct dryer airflow and increase the risk of fire Do not install or store this appliance in any location where it could be exposed to water and or weather Save th
19. the rear opening and connect it to the dryer internal duct e Apply duct tape on the joint between the dryer internal duct and elbow as shown on page 7 CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET PLATE KIT WE1M454 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M454 available from your local service provider Place dryer in final location A WARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE 14 CHANGING DIRECTION OF DOOR OPENING 1 Open the door and remove the filler plugs opposite the hinges With the door completely open remove the bottom screws from each hinge on the dryer face Insert these screws about half way into the TOP holes for each hinge on the opposite side where you removed the filler plugs Apply firm pressure to get the screws started REMOVE 4 PLUGS AND KEEP REMOVE BOTTOM SCREW FROM EACH HINGE FOR INSERTION INTO AND INSTALL HALF WAY INTO EACH TOP OF THE OPPOSITE SIDE OPPOSITE HINGE HOLES 2 Loosen the top screws from each hinge on the dryer face half way With one hand holding the top ofthe door and the other hand holding the bottom remove the door from the dryer by lifting it UP and OFF LOOSEN EACH TOP HINGE SCREW HALF WAY AND LIFT THE DOOR UP AND OFF i SWITCH Remove the blind plate fro
Download Pdf Manuals
Related Search
Related Contents
Manual del Usuario Monitor de Nivel de Sonido Modelo SL120 lit-210 sunoptic technologies 6 bay battery Nuance Dragon NaturallySpeaking Professional 11 Mode d`emploi GRS-A-3348 3Com 3CRWE53172 Network Router User Manual hot water pellet boiler of series “PELLETHERM V4” Toyano truck stage CyberPower CyberShield CS24U12V-12 User's Manual Copyright © All rights reserved.