1. close the battery cover CyberShield UPSs are designed to provide a local power solution for cable telephony wireless local loop WLL and fiber to the home FTTH broadband equipment IMPORTANT SAFETY WARNINGS SAVE THESE INSTRUCTIONS This manual contains important instructions regarding the installation and operation of this device Read this manual thoroughly before attempting to unpack install or operate this device CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery No user serviceable parts inside except for the battery CAUTION To avoid electric shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component OPERATION Connect Equipment and Power Step1 Plug the UPS power cord into the utility power cord inlet Step2 Plug the UPS power cord into the wall outlet The UPS battery charges when it is connected to utility power The battery charges N fully during the first 24 hours of normal operation Do not expect full battery run capability during this initial charge pe
2. the hole and press the button In case of utility failure on battery it will emit a long beep In case of Battery low battery it will emit a short beep Battery Type Sealed Maintenance Free Lead Acid Battery COMMUNICATION SIGNALS Numbers of Battery 7 2AH I12V x 1 12AH 12V x 1 20AH 12V x 1 The communication signals of this unit are isolated from the internal circuitry via open collector opto Typical Recharge Time 48Hours 24Hours A2Hours 24Hours coupled transistors The connection SIG RTN Signal Return is a common return point for all Replaceable Yes communication signals In the typical application the attached equipment digital ground connects to p Signal Return and pull up resistors turn the open collector signals into logic levels Surge Protection and Filtering Lightning Surge Protection Yes Warning Diagnostics ee lil 24U12V i CS50U48 15 desis CS24U12V 12 Indicators AC Output Battery CS30U12V 20 Management Auto Charge Yes On Battery Replace Battery Battery Missing Low Battery CS24U12V Communication Interface CS24U12V 12 CS30U12V 20 12V 48V CS50U48V Message Physical Voltage output 30cm x 28cm x 9 9cm 12V RTN 48V RTN SIG RTN SIG RTN Voltage output Signal return ON BATTERY ON BATTERY Low when operating from utility line Open when operating from battery REPLACE BATTERY REPLACE BATTERY Low when battery is charged Open when battery fails the Self Tes
3. CyberPower User s Manual for CyberShield CSS5S0U48V CS24U12V CS24U12V 12 CS30U12V 20 ENCLOSURE INSTALLATION Carefully follow these instructions during installation of this device 1 Carry out the installation in a safe area that is free of excessive dust and has adequate airflow 2 Screws must be appropriate for total weight of the UPS and the mounting surface material 3 Do not operate the UPS where the temperature and humidity are outside the specified limits Refer to specification in this manual CS5S0U48V CS30U12V 20 CS24U12V CS24U12V 12 Step 1 Step 2 Step 3 a Remove the battery cover a Unstrap strap from battery a Use the enclosed installation template to b Slide battery off of the mark an installation location for the unit shelf b Mount the unit on the wall with 2 mounting c Disconnect battery cable screws into the keyhole slots connector at chassis end Tighten the screws to secure the units d Connect the battery connector and replace the battery back Q BATTERY REPLACEMENT This battery is hot swappable As long as utility power is on you may leave the UPS and connected equipment on while replacing a new battery CS24U12V a Loosen the battery strap CS24U12V 12 b Disconnect battery cable connector Step 13 to remove battery Step 3 a Remove the battery cover c Replace with new battery and a Tighten the battery strip and re connect the battery connector
4. Product at the time of the failure that results in the claim made under this Limited Warranty Your sole and exclusive remedies are those provided by this Limited Warranty This exclusion of other express warranties applies to written and oral express warranties CyberPower excludes any liability for personal injury CyberPower excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property loss of profits business interruption information or data This exclusion applies even though damage or loss is caused by negligence or other fault NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES CyberPower does not sell the PRODUCT for use in high risk activities The PRODUCT is not designed or intended for use in hazardous environments requiring fail safe performance including the operation of nuclear facilities aircraft navigation or communication systems air traffic control weapons systems life support or medical applications or for use in any circumstance in which the failure of the PRODUCT could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities CyberPower express
5. ly disclaims any express or implied warranty of fitness for High Risk Activities CyberPower does not authorize use of any PRODUCT in any High Risk activities ANY SUCH USE IS IMPROPER AND IS A MISUSE OF A CYBERPOWER PRODUCT The Limited Warranty is governed by the laws of the United States and the State of Minnesota without reference to conflict of law principles The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded FCC NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with these instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which
6. riod COLD START The cold start feature is for applying power to the UPS and connected equipment when the UPS is off and there is no utility power Before using the cold start feature please make sure the battery is charged To start the cold start feature press the recessed cold start button with a small pointed object Once the battery is disconnected the connected equipment is not protected from power outages replacement battery packing material Deliver spent batteries to a recycling facility or ship to the manufacturer in the lis pb WARNING INDICATOR Indicator Color Condition Green UPS is on utility power Yellow UPS is on battery power DC output power is provided by the battery or utility power The battery is not connected or the battery needs to be replaced CS24U12V CS24U12V 12 CS50U48V CS30U12V 20 SPECIFICATION Back Panel CS24U12V CS24U12V 12 CS30U12V 20 CS50U48V Input Voltage Range 85Vac 264Vac Universal Input Frequency Range 47 70 Hz Output On Battery Output Voltage 12Vdc Continuous Power Capability 24W 30W CS24U12V CS24U12V 12 CS50U48V CS30U12V 20 Output Power Max SAW 30W Buzzer On Off Switch the aerau position of ine buzzer switch is OFF If you wani to enable this Efficiency at 75 Max Load gt 75 function there is a button inside the hole please insert a paper clip or small pointed object into
7. t BATTERY BATTERY MISSING MISSING LOW BATTERY LOW BATTERY Low when battery is present Open when battery is missing Low when battery is near full charge Maximum Dimensions L W D 16 7cm x 24cm x 8 1cm Weight kg Environment Operating Temperature Operating Humidity 32 F 104 F 0 40 C 0 95 noncondensing within enclosure Max Operating Elevation 10 000ft 3 000m Max Storage Elevation Storage Temperature 50 000ft 15 000m BOF 113 F 15 C 45 C capacity Open when operating from a battery with lt 20 capacity LIMITED WARRANTY CyberPower warrants to you the Initial Purchaser that the Product will be free from defects in material and workmanship for three years from the date of original purchase subject to the terms of this Limited Warranty This Limited Warranty gives you specific rights and you may have other rights which vary from State to State or Province to Province Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose if applicable to the Product is limited in duration to three years This provision shall NOT create any Implied Warranty or Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product NOTE Some States and Provinces do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you To be covered you must still be the owner of the
8. the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help CAUTION Shielded signal cables must be used with this device to ensure compliance with Class B FCC limits CAUTION Any changes or modifications not expressly approved by Cyber Power could void the authority granted by the FCC to operate this equipment For more information please contact CyberPower Systems USA Inc 5555 12th Avenue East Suite 110 Shakopee MN55379 CyberPower Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands CyberPower Phone 952 403 9500 Fax 952 403 0009 E mail sales cyberpower eu com www cyberpowersystems com eu cyberpowersystems com K01 3012000