Honeywell Thermostat TH1100DH User's Manual

image

Contents

1. TONVdSA TONVdSA Guia de instalacion Cableado Guia de cableado sistemas convencionales y de bomba de calor Sistema de bomba de calor de S00Y30S 2 calentadores B OG YAuxiC R eet y 1 refrigerador E M32809 TH2210DH TH1210DH B Valvula inversora alimentada durante la calefaccion 5 O V lvula inversora alimentada durante la refrigeraci n 5 G Rel del ventilador Y Interruptor autom tico del compresor Aux E Rel auxiliar de calor 9 Cc 24 V CA 3 R Electricidad 1 Sistema de 1 calentador y 1 refrigerador SY WOC R Re M32811 TH2110DH TH1110DH 1 transformador G Rel del ventilador Y Interruptor autom tico del compresor Ww Rel de calor Cc 24 V CA 3 R R Rc unidos por un puente Re Electricidad 1 Sistema de 1 calentador y 1 refrigerador TH2110DH TH1110DH 2 transformadores Rel del ventilador Interruptor autom tico del compresor Rel de calor 24 V CA 3 4 Electricidad transformador de calefacci n 1 2 Electricidad transformador de refrigeraci n x 0 s lt o Sistema de bomba de calor de 1 calen tador y 1 refrigerador TH2110DH TH1110DH 7 B OG Y W CR Rc M32813 B Valvula inversora alimentada durante la calefaccion 5 O V lvula inversora alimentada durante la refrigeraci n 5 G Rel del ventilador Y Interruptor au
2. 1H 1C System TH2110DH TH1110DH 2 transformers G Fan relay Y Compressor contactor Ww Heat relay Cc 24 Vac common 3 4 R Power heating transformer 1 2 Re Power cooling transformer 1 2 ADVE Heat Only System TH1100DH W C R Not Used w Heat relay M32817 c 24Vac common 3 R Power 1 See notes below NOTES Wire specifications Use 18 to 22 gauge thermostat wire Shielded cable is not required 1 Power supply Provide disconnect means and overload protection as required 2 Remove jumper for 2 transformer systems 3 Optional 24 Vac common connection 69 2609EFS 03 Re Power 1 Heat Only System TH2110DH TH1110DH Ww Heat relay Cc 24Vac common 3 C R R Rc joined by jumper Re Power 1 Heat Only System with a Fan TH2110DH TH1110DH G Fan relay W Heat relay Cc 24 Vac common 3 R R Rc joined by jumper Re Power 1 Cool Only System G Y C R Re TH2110DH TH1110DH Maama G Fan relay Y Compressor contactor c 24 Vac common 3 R R Rc joined by jumper Re Power 1 4 Common connection must come from cooling transformer 5 Use either O or B terminals for changeover valve 6 Use a small piece of wire not supplied to connect W and Y terminals 7 Set fan operation switch to Heat Pump see page 5 PRO TH2000DH TH1000DH Series Fan operation settings TH2110DH T
3. Hale de la parte inferior para quitar Quite la placa para pared del termostato el termostato de la placa para pared como se muestra a la izquierda y luego siga las instrucciones para el montaje 1 Hale los cables a trav s del agujero para los cables 2 Coloque la placa en la pared nivele y marque las posiciones de los agujeros 3 Realice agujeros en las posiciones marcadas como se muestra abajo e introduzca las anclas de expansi n con golpes leves BQqoa4gBga REMOVE WALLPLATE PULL HERE Y 4 Coloque la placa para pared sobre las anclas ma0794 de expansi n introduzca los tornillos de montaje y aj stelos En tablarroca realice agujeros de 3 16 En yeso realice agujeros de 7 32 Agujero para el cable Tornillos de montaje Anclas de expansi n M32805 PRECAUCI N RIESGO EL CTRICO Puede ocasionar descargas el ctricas o da ar el equipo Descon ctelo de la fuente de energ a antes de comenzar la instalaci n AVISO SOBRE EL MERCURIO A En caso de que este producto reemplace a un control que contenga mercurio en tubo sellado evite arrojar el viejo control a la basura Comun quese con Thermostat Recycling Corporation en www thermostat recycle org o llame al 800 238 8192 para obtener informaci n sobre c mo y d nde desechar de forma adecuada y segura su termostato usado 69 2609EFS 03 2 Serie PRO TH2000DH TH1000DH Opciones de fuentes de energia ESTA AR
4. Recommand pour la plupart des compresseurs Autres options possibles 1 2 4 5 ou 6 CPH En marche Voir page 8 A l arr t Fahrenheit Celsius Temporisation de 5 minutes Voir page 8 Aucun temps de coupure du compresseur Format 12 heures Format 24 heures Gamme standard 4 5 32 C 40 90 F Gamme faible pour le mode garage 1 5 32 C 35 90 F Arr t On Marche Les r glages par d faut du calendrier sont indiqu s dans le manuel de fonctionnement MISE EN GARDE RISQUE DE DOMMAGE MAT RIEL Le syst me ne tient pas compte du temps d arr t minimal du compresseur pendant le test par l installateur Pour viter d endommager le mat riel viter les cycles de fonctionnement trop rapides du compresseur 7 69 2609EFS 03 SIVNVHA Guide d installation Fonctions sp ciales D marrage pr coce fonction de configuration 13 Le d marrage pr coce permet l appareil de chauffage et au climatiseur de se mettre en marche avant le temps programm pour que la temp rature voulue soit obtenue l heure programm e Protection du compresseur Configuration de la fonction 15 Cette fonction oblige le compresseur attendre quelques minutes avant de red marrer Pendant cette attente les mots Cool On ou Heat On si le syst me utilis est une thermopompe clignotent l cran Accessoires et pi ces de rechange Pri re de communiquer avec le distributeur pour c
5. 03 Cc Commun 24 V c a 3 C R R Rc reli es par un cavalier Re Alimentation 1 Syst me de chauffage seulement avec ventilateur TH2110DH TH11 10DH G Relais de ventilateur WwW Relais de chauffage C Commun 24 V c a 3 R R Rc reli es par un cavalier Re Alimentation 1 Syst me de refroidissement AXES VEAN seulement GND TEER RE TH2110DH TH1110DH G Relais de ventilateur Y Contacteur du compresseur Commun 24 V c a 3 R Rc reli es par un cavalier Alimentation 1 4 La connexion commune doit provenir du transformateur de refroidissement 5 Utiliser soit la borne O soit la borne B pour la vanne d inversion 6 Utiliser un petit bout de fil non fourni pour raccorder les bornes W et Y 7 R gler le s lecteur du ventilateur la position Thermopompe Heat Pump voir page 5 S rie PRO TH2000DH TH1000DH R glage du ventilateur TH21100DH TH1110DH seulement R gler le s lecteur du ventilateur Montage du thermostat Aligner les deux languettes en haut de la plaque murale avec les fentes correspondantes au dos du thermostat puis pousser doucement jusqu ce que le thermostat soit en place Gaz ou mazout Dans le cas de systemes de chauffage au gaz ou au mazout laisser le s lecteur du ventilateur a la position r gl e en usine Ce r glage convient aux systemes qui commandent le fonctionnement du vent
6. Honeywell Installation Guide 000 EH PRO TH2000DH TH1000DH Series Thermostats This manual covers the following models e TH1100DH For Heat only systems e TH2110DH TH1110DH For 1 Heat 1 Cool systems e TH2210DH TH1210DH For 2 Heat 1 Cool heat pump systems only Pull thermostat from wallplate and turn over to find model number System Types TH2110DH TH1110DH TH2210DH TH1210DH e Gas oil or electric heat with air e 2Heat 1 Cool heat pumps conditioning TH1100DH e Warm air hot water high efficiency furnaces 1 Heat 1 Cool heat pumps e Gas oil or electric heat steam gravity e Warm air hot water steam gravity e Heat only e Heat only e Heat only with fan e 750 mV heating systems e Cool only e 750 mV heating systems Must be installed by a trained experienced technician Read these instructions carefully Failure to follow these instructions can damage the product or cause a hazardous condition Need Help For assistance with this product please visit http customer honeywell com or call Honeywell Customer Care toll free at 1 800 468 1502 U S Registered Trademark Patents pending Copyright 2011 Honeywell International Inc All rights reserved 69 2609EFS 03 HSITONA Installation Guide Walliplate installation Pull at bottom to remove thermostat Remove the wallplate from the thermostat from wallplate as shown at left then follow directions below for mounting 1 Pu
7. See page 8 No compressor off time 12 hour display 24 hour display Standard range 40 F to 90 F 4 5 C to 32 C Lower range for garage mode 35 F to 90 F 1 5 C to 32 C Off On program schedule default settings are listed in the operating manual CAUTION EQUIPMENT DAMAGE HAZARD Compressor protection is bypassed during testing To prevent equipment damage avoid cycling the compressor quickly 7 69 2609EFS 03 HSITONA Installation Guide Special functions Early Start Setup Function 13 Early start allows the heating or cooling to turn on before the program start time so the temperature is reached at the time you set Compressor Protection Setup Function 15 Forces the compressor to wait a few minutes before restarting to prevent damage During the wait time the message Cool On or Heat On heat pumps only will flash on the display Accessories amp replacement parts Please contact your distributor to order replacement parts Cover plate assembly Part Number 50002883 001 Use to cover marks left by old thermostats Specifications Temperature Ranges Electrical Ratings e Heat 40 to 90 F 4 5 to 32 C System Voltage 50 60Hz Running Current e Cool 50 to 99 F 10 to 37 C Heat 1st stage 20 30 Vac 0 02 1 0 A Operating Ambient Temperature Powerpile 750 mV DC 100 mA DC e 32 to 120 F 0 to 48 9 C Auxiliary heat 20 30 Vac 0 02 1 0
8. TH1000DH Configuraciones de funcionamiento del ventilador TH2110DH TH1110DH nicamente e Gas o aceite Para sistemas de calefacci n a gas 0 a aceite deje el interruptor del ventilador en esta posici n predeterminada de f brica esta posici n es para los sistemas que controlan el ventilador cuando se necesita calefacci n e Bomba el ctrica o de calor Cambie el interruptor a esta posici n para los sistemas de bomba de calor o de calefacci n el ctricos esta posici n es para los sistemas que controlan el GAS OR OIL ventilador cuando se necesita calefacci n Si se conecta un cable del ventilador al A CR LIEAT FUMER terminal G M32818 Interruptor de funcionamiento del ventilador Montaje del termostato Alinee las 2 pesta as en la parte superior de la placa de pared con las ranuras correspondientes de la parte posterior del termostato seguidamente presione suavemente hasta que el termostato enganche a presi n en su lugar Coloque el excedente de cable en el interior de la abertura de la pared Tape la abertura de la pared con un aislamiento no inflamable Y Fan Rael Heat Off Cool M32757 Fan Ta Heat Off Cool M32705 5 69 2609EFS 03 TONVdSA TONVdSA Guia de instalaci n Configuraci n de instalaci n Siga el procedimiento que aparece a continuaci n para configurar el termostato a fin de que se corresponda
9. A Cooling 20 30 Vac 0 02 1 0 A Shipping Temperature e 20 to 120 F 28 9 to 48 9 C Operating Relative Humidity e 5 to 90 non condensing Physical Dimensions e 3 7 16 H x 4 10 16 W x 1 3 16 D 87mm H x 119mm W x 30mm D Automation and Control Solutions Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 http customer honeywell com Honeywell U S Registered Trademark 2011 Honeywell International Inc 69 2609EFS 03 M S Rev 06 11 Printed in U S A Honeywell 2 G s g Guide A d installation El Y S rie PRO TH2000DH TH1000DH Thermostats Le pr sent guide porte sur les mod les suivants e TH1100DH Pour syst mes de chauffage seulement e TH2110DH TH1110DH Pour syst mes 1 tage de chauffage 1 tage de refroidissement e TH2210DH TH1210DH Pour thermopompes 2 tages de chauffage 1 tage de refroidissement seulement Retirer le thermostat de la plaque murale et le retourner pour trouver le num ro de mod le Types de syst me TH2110DH TH1110DH TH2210DH TH1210DH e Gaz mazout ou chauffage lectrique e Thermopompes 2 tages de avec climatisation chauffage 1 tage de refroidissement e Air chaud eau chaude appareils TH1100DH de chauffage a haut rendement A thermopompes 1 tage de chauffage 1 e Gaz mazout ou chauffage lectrique tage de refroidissement vapeur et e Air chaud eau chaude vapeur et gravit gravit e Chauf
10. EA SOMBREADA MANTENGA LOS CABLES EN QUITE EL PUENTE INSTALADO EN LA FABRICA SOLO EN LOS SISTEMAS CON DOS TRANSFORMADORES SE MUESTRA EL BLOQUE DE TERMINALES DEL MODELO de SD20808S BOGYWC RRc CONECTE C PARA SUMINISTRAR CORRIENTE CA OPCIONAL SI LAS BATERIAS ESTAN INSTALADAS MS32806 Cableado Designaci n de terminales TH2110DH TH1110DH Valvula inversora alimentada durante la refrigeraci n O V lvula inversora alimentada durante la refrigeraci n G Rel del ventilador Y Interruptor autom tico del compresor Ww Rel de calor C 24 V CA Para los sistemas de 2 transformadores utilice cables comunes desde el transformador de la refrigeraci n R Corriente de 24 V CA del transformador de calefacci n Rec Corriente de 24 V CA del transformador de refrigeraci n TH2110DH TH1110DH BOGYWCRRe M32808 TH1100DH Ww Rel de calor TH1100DH C 24VCA NINJA Corriente de 24 V CA W C R Not Used M32810 COLOQUE LAS BATERIAS PARA SUMINISTRO DE ENERGIA PRINCIPAL O DE RESPALDO LE o Lie La 00000 MS32807 TH2210DH TH1210DH B Valvula inversora alimentada durante la refrigeraci n o V lvula inversora alimentada durante la refrigeraci n G Rel del ventilador Y Interruptor autom tico del compresor Aux E Rel auxiliar de calor c 24 V CA R Corriente de 24 V CA y id 0DH BO 5 TEE R Not E Used M32809 69 2609EFS 03
11. H1110DH only e Gas or Oil For gas or oil heating systems leave the fan operation switch in this factory set position This setting is for systems that control the fan in a call for heat e Electric or Heat Pump Change the switch to this setting for heat pump or electric heat systems This setting is for systems that allow the thermostat to control the fan in a call for heat if a fan wire is connected to the G terminal ES OR OIL em ELECTRIC OR HEAT PUMP aes OR OIL ELECTRIC OR HEAT PUMP Set fan operation switch Thermostat mounting Align the 2 tabs at the top of the wall plate with corresponding slots on the back of the thermostat then push gen tly until the thermostat snaps in place Push excess wire back into the wall opening Plug wall opening with non flammable insulation M32757 M32705 5 69 2609EFS 03 HSITONA HSIMON3 Installation Guide Installer setup Follow the procedure below to configure the thermostat to match the installed heating cooling system and customize feature operation as desired To begin press and hold the and buttons until the display changes Fan Fan Heat Off Cool l auto on Heat Off Cool l auto on M32713 M32758 E J 5 i M32819 Press the A or Y button to change the setting Setting Function number Press the A and W buttons simultaneously for one second to adva
12. ational Inc 1985 Douglas Drive North Golden Valley MN 55422 http customer honeywell com Honeywell Marca Registrada en los E U A O 2011 Honeywell International Inc 69 2609EFS 03 M S Rev 06 11 Impreso en EE UU
13. con el sistema de calefacci n y refrigeraci n instalado y seleccione las funciones seg n lo desee Para comenzar pulse y mantenga presionados los botones y W hasta que cambie la pantalla Heat Off Cool M32713 M32758 Configuraci n J 35 Presione el bot n A o Y para cambiar la configuraci n N mero de funci n Presione los botones A y Y al mismo tiempo por un segundo para ir a la funci n siguiente Pulse y mantenga presionados los botones A y Y para salir y guardar la configuraci n NOTA si no se presiona ning n bot n durante 60 segundos mientras est abierto el men de configuraci n el termostato salvaguarda los cambios autom ticamente y sale del men 69 2609EFS 03 6 Serie PRO TH2000DH TH1000DH Configuraci n de instalaci n Funciones de Configuraciones y opciones las que vienen la configuraci n desde la f brica aparecen en negrita 5 Velocidad del ciclo 5 Para sistemas de calefacci n a gas o a aceite de t rmico menos de un 90 de efectividad CPH ciclos por hora 1 Para sistemas de vapor o de gravedad TH2110DH TH1110DH 3 Para sistemas de agua caliente y sistemas de m s de y TH1100DH un 90 de efectividad 6 Para sistemas de calefacci n el ctricos Otras opciones de rango de ciclos 2 4 CPH 6 Velocidad del ciclo 5 Para sistemas de calefacci n a gas o a aceite de t rmico auxiliar CPH menos TH2210DH TH1210DH de un 90 de efe
14. ctividad Para sistemas de vapor o de gravedad 3 Para sistemas de agua caliente y sistemas de mas de un 90 de efectividad 6 Para sistemas de calefacci n el ctricos Otras opciones de rango de ciclos 2 4 CPH 9 Rango de ciclos 3 Recomendado para la mayor a de los compresores del compresor CPH Otras opciones de rango de ciclos 1 2 4 5 6 CPH 13 Encendido anticipado 1 On encendido Vea la p gina 8 TH2110DH y 0 Off apagado TH2210DH 14 Visor de temperatura O Fahrenheit Celsius 15 Protecci n del 5 Tiempo de apagado del compresor Vea la p gina 8 compresor O Sin tiempo de apagado del compresor 20 Visualizador del O Visualizador de 12 horas reloj TH2110DH y 1 Visualizador de 24 horas TH2210DH 25 Rango de temperatura O Rango est ndar 40 F a 90 F 4 5 C a 32 C m s bajo solo 1 Rango m s bajo para el modo garaje 35 F a 90 F TH1100DH 1 5 C a 32 C 40 Restablecimiento O Off apagado del cronograma 1 On encendido la configuraci n del cronograma del programa a del programa est n indicados en el manual de la configuraci n funcionamiento predeterminada TH2110DH y TH2210DH Durante la prueba se desactiva la protecci n del compresor Para evitar da os PRECAUCION PELIGRO DE DANO EN EL EQUIPO en el equipo no permita que el compresor funcione a velocidades altas 7 69 2609EFS 03 TONVdSA Guia de instalaci n Funciones especiales Encendido anticipado funci n de con
15. eating O Changeover valve energized in O Changeover valve energized in cooling cooling G Fan relay G Fan relay Y Compressor contactor Y Compressor contactor W Heat relay Aux E Auxiliary heat relay C 24 Vac common For 2 transformer C 24 Vac common systems use common wire from R 24 Vac power cooling transformer R 24 Vac power from heating transformer Re 24 Vac power from cooling TH2210DH TH1210DH transformer AU ERSS TH2110DH B O G YAux C R Not TH1110DH E M32809 BOGYWCRRe M32808 TH1100DH W Heat relay TH1100DH C 24 Vac common R 24 Vac power Ms M32810 3 69 2609EFS 03 HSITONA HSIMON3 Installation Guide Wiring guide conventional and heat pump systems 2H 1C Heat AR ES 1H 1C Heat Pump System B O G Yau C R Not Pump System B OGY WCR Re TH2210DH TH1210DH E Mozos TH2110DH TH1110DH 7 Maass B Changeover valve energized in B Changeover valve energized in heating 5 heating 5 o Changeover valve energized in o Changeover valve energized in cooling 5 cooling 5 G Fan relay G Fan relay Y Compressor contactor Y Compressor contactor 6 Aux E Auxiliary heat relay C w W Y joined by jumper c 24 Vac common 3 c 24 Vac common 3 R Power 1 R R Rc joined by jumper 1H 1C System TH2110DH TH1110DH 1 transformer G Y W CR Rc G Fan relay M32811 Y Compressor contactor Ww Heat relay Cc 24 Vac common 3 R R Rc joined by jumper Re Power 1
16. fage seulement e Chauffage seulement e Syst mes de chauffage 750 mV e Chauffage seulement avec ventilateur e Refroidissement seulement e Syst mes de chauffage 750 mV Doit tre install par un technicien d exp rience ayant re u la formation pertinente Lire attentivement les instructions Le fait de ne pas les suivre risque d endommager le produit ou de constituer un danger Besoin d aide Pour obtenir de l assistance au sujet de ce produit consulter le http customer honeywell com ou t l phoner sans frais au Centre de service a la client le de Honeywell au 1 800 468 1502 Marque d pos e aux U Brevets en instance 2011 Honeywell International Inc Tous droits r serv s SIVONVUS Guide d installation Installation de la plaque murale Tirer le thermostat par le bas pour le S parer la plaque murale du thermostat detacherdela plague murale comme l indique illustration ci contre puis suivre les directives d installation ooh 00 1 Faire passer les fils par l ouverture r serv e aux fils 2 Placer la plaque murale sur le mur mettre de R 0 niveau et marquer au crayon l emplacement des trous 20808000 TO REMOVE WALLPLATE 3 Percer les trous aux endroits marqu s l aide PULL HERE z g d une perceuse puis ins rer les chevilles MT d ancrage fournies 4 Apposer la plaque murale sur les chevilles ins rer puis resserre
17. figuraci n 13 permite que la refrigeraci n o la calefacci n arranquen antes de la hora de inicio programada de manera que se alcance esa temperatura a la hora que usted configur Protecci n del compresor conversi n autom tica configuraci n 15 Hace que el compresor demore unos minutos antes de volver a iniciarse a fin de evitar da os Durante el tiempo de espera el mensaje Cool On o Heat On bombas de calor nicamente titilar en la pantalla Accesorios y piezas de repuesto P ngase en contacto con su distribuidor para solicitar piezas de repuesto Ensamblado de la placa de cubierta N mero de pieza 50002883 001 selo para cubrir las marcas que dejan los termostatos viejos Especificaciones Rangos de temperatura Rangos el ctricos Poy corel a Sistema Voltaje 50 60 Hz Corriente e Frio De 50 F a 99 F Calor etapa 1 de 20a30VCA de0 02a1 0A de 10 C a 87 C Powerpile 750 mV CC 100 mA CC Temperatura ambiente Calentador de 20a30VCA de0 02a1 0A de funcionamiento auxiliar i fee oC ane 0 Refrigeraci n de20a30VCA de0 02a1 0A Temperatura de embalaje e De 20 F a 120 F de 28 9 C a 48 9 C Humedad relativa de funcionamiento e 5 a 90 no condensable Dimensiones fisicas e 3 7 16 de altura x 4 10 16 de ancho x 1 3 16 de profundidad 87 mm de altura x 119 mm de ancho x 30 mm de profundidad Automatizaci n y control desenlace Honeywell Intern
18. ges REMARQUE Si aucun bouton n est touch pendant 60 secondes dans le menu de configuration le thermostat enregistre automatiquement toute modification effectu e et quitte le menu 69 2609EFS 03 6 S rie PRO TH2000DH TH1000DH Mode de configuration par l installateur Fonctions 5 Nombre de cycles de chauffage l heure CPH cycles par heure TH2110DH TH1110DH et TH1100DH 6 Cycles par heure du chauffage auxiliaire CPH TH2210DH TH1210DH 9 Cycles par heure du compresseur CPH 13 D marrage pr coce TH2110DH et TH2210DH 14 Affichage de la temp rature 15 Protection du compresseur 20 Affichage de l horloge TH2110DH et TH2210DH 25 Gamme de temp rature faible TH1100DH seulement 40 Restaurer le r glage par d faut du calendrier TH2110DH et TH2210DH R glage et options r glages de l usine en gras 5 _ 3 Pour les appareils au gaz ou au mazout moins de 90 d efficacit Syst mes vapeur ou gravit Syst mes et appareils de chauffage eau chaude plus de 90 d efficacit Pour appareils de chauffage lectriques autres CPH possibles 2 ou 4 CPH Pour les appareils au gaz ou au mazout moins de 90 d efficacit Syst mes vapeur ou gravit Syst mes et appareils de chauffage eau chaude plus de 90 d efficacit Pour appareils de chauffage lectriques autres CPH possibles 2 ou 4 CPH
19. ilateur lors d une demande de chauffage Electricit ou thermopompe D placer le s lecteur a cette position si le systeme est une thermopompe ou un appareil de chauffage lectrique A cette position le thermostat commande la mise en marche du ventilateur lors d une demande de chaleur si un fil du ventilateur est raccord a la borne G dans le mur dans le mur au N ininflammable Heat Off Cool M32705 5 Repousser le fil en exc s dans l ouverture Boucher l ouverture moyen d un isolant OR OIL 25 ELECTRIC OR HEAT PUMP M32818 Heat Off Cool Fan Rael M32757 69 2609EFS 03 SIVONVYS Guide d installation Mode de configuration par l installateur Suivre les directives ci dessous pour configurer le thermostat pour qu il corresponde au syst me de chauffage refroidissement install et pour personnaliser son fonctionnement Pour commencer Appuyer sur les boutons A et W les maintenir enfonc s jusqu ce que Paffichage change Heat Off Cool Heat Off Cool M32713 M32758 E eA 5 R glage via M32819 Num ro de fonction Appuyer sur le bouton A ou W pour modifier les r glages Appuyer simultan ment sur les boutons A et W pendant une seconde pour passer a la fonction suivante Appuyer sur les boutons A et Y et les maintenir enfonc es pour quitter et enregistrer r gla
20. ll wires through wire hole 2 Position wallplate on wall level and mark hole positions with pencil 3 Drill holes at marked positions as shown below OUCDCO0C then tap in supplied wall anchors TO REMQVE WALLPLATE POLL HERE 4 Place wallplate over anchors insert and tighten mounting screws M32731 Drill 3 16 holes for drywall Drill 7 32 holes for plaster Wire hole Mounting screws Wall anchors M32805 CAUTION ELECTRICAL HAZARD Can cause electrical shock or equipment damage Disconnect power before beginning installation MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube do not place the old control in the trash Contact the Thermostat Recycling Corporation at www thermostat recycle org or 800 238 8192 for information on how and where to properly and safely dispose of your old thermostat 69 2609EFS 03 2 PRO TH2000DH TH1000DH Series Power options KEEP WIRES IN THIS SHADED AREA INSERT BATTERIES FOR REMOVE FACOTRY PRIMARY OR BACKUP POWER INSTALLED JUMPER ONLY FOR TWO TRANSFORMER SYSTEMS TH2110DH TERMINAL Y BLOCK SHOWT SVISSVOS BO G Y WC RRd CONNECT C FOR PRIMARY AC POWER OPTIONAL IF BATTERIES ARE INSTALLED M32807 M32806 Terminal designations TH2110DH TH1110DH TH2210DH TH1210DH B Changeover valve energized in B Changeover valve energized in heating h
21. n 24 V c a Dans les syst mes deux transformateurs utiliser le fil commun du transformateur de refroidissement R Alimentation 24 V c a provenant du transformateur de chauffage Rc Alimentation 24 V c a provenant du transformateur de refroidissement TH2110DH TH1110DH BOGYWCRRe M32808 TH1100DH W Relais de chauffage TH1100DH C Commun 24 V c a NDIE R Alimentation 24 V ca W C R Not Used M32810 INS RER LES PILES POUR L ALIMENTATION PRIMAIRE OU DE SECOURS TH2210DH TH1210DH B Vanne d inversion d clench e en mode de chauffage o Vanne d inversion d clench e en mode de refroidissement G Relais de ventilateur Y Contacteur du compresseur Aux E Relais de syst me de chauffage auxiliaire C Commun 24 V c a R Alimentation 24 V c a TH2210DH TH1210DH AUX B O G YAux C R Not E Used M32809 69 2609EFS 03 MF32807 SIVONVUS SIVONVUS Guide d installation C blage Guide de c blage syst mes classiques et thermopompes Thermopompes xD IN SS Thermopompe 2C 1F O YAus G R Not 1C 1F BOG YWCR Rc TH2210DH TH121 ODH Pis TH2110DH TH1110DH 7 nee B Vanne d inversion d clench e en B Vanne d inversion d clench e en mode de chauffage 5 mode de chauffage 5 o Vanne d inversion d clench e en o Vanne d inversion d clench e en mode de refroidissement 5 mode de refroidissement 5 G Relais de ventilateur G Relais de ventilate
22. nce to the next function Press and hold the A and W buttons to exit and save settings NOTE If you do not press any button for 60 seconds while you are in the setup menu the thermostat automatically saves any changes made and exits the menu 69 2609EFS 03 6 PRO TH2000DH TH1000DH Series Installer setup Settings amp options factory default in bold Setup function 13 14 15 20 25 40 Heating cycle rate CPH cycles hour TH2110DH TH1110DH and TH1100DH Auxiliary heat cycle rate CPH TH2210DH and TH1210DH Compressor cycle rate CPH Early Start TH2110DH and TH2210DH Temperature display Compressor protection Clock display TH2110DH and TH2210DH Lower temperature range TH1100DH only Restore program schedule to default TH2110DH and TH2210DH O O1 O 01 ou 6 om 20 For gas or oil furnaces of less than 90 efficiency For steam or gravity systems For hot water systems amp furnaces of over 90 efficiency For electric furnaces Other cycle rate options 2 or 4 CPH For gas or oil furnaces of less than 90 efficiency For steam or gravity systems For hot water systems amp furnaces of over 90 efficiency For electric furnaces Other cycle rate options 2 or 4 CPH Recommended for most compressors Other cycle rate options 1 2 4 5 or 6 CPH On See page 8 Off Fahrenheit Celsius Five minute compressor off time
23. ommander des pi ces de rechange Ensemble de plaques de recouvrement occoocccncccccccccnnno N de pi ce 50002883 001 Sert masquer les marques laiss es par l ancien thermostat Caract ristiques techniques Gammes de temp rature Caract ristiques lectriques nominales e Chauffage 4 5 32 C 40 90 F Syst me Tension Intensit e Refroidissement 10 37 C 50 99 F 50 60 Hz de service Gamme de temp rature Chauffage ler tage 20 30 V c a 0 02 1 0 A ambiante de service Powerpile 750 mV c c 100 mA c c e 0 48 9 C 32 120 F Chauffage auxiliaire 20 30 V c a 0 02 1 0 A Temp rature exp dition Refroidissement 20 30 V c a 0 02 1 0 A e 28 9 48 9 C 20 120 F Humidit relative de service e 5 90 sans condensation Encombrement e 3 7 16 po H x 4 10 16 po L x 1 3 16 po P 87 mm H x 119 mm L x 30 mm P Solutions de r gulation et d automatisation Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 http customer honeywell com Honeywell Marque de commerce d pos e aux U 2011 Honeywell International Inc 69 2609EFS 03 M S Rev 06 11 Imprim aux Etats Unis Honeywell e Esa g Gu a de iia instalaci n oR Serie PRO TH2000DH TH1000DH Termostatos Este manual incluye los siguientes modelos e TH1100DH Para sistemas de S lo calor e TH2110DH TH1110DH Para sistemas de 1 calen
24. r les vis de fixation Utiliser une m che de 3 16 po Utiliser une m che de 7 32 po si le mur est en placopl tre si le mur est en pl tre Trou du fil Vis de montage Ancrages muraux MISE EN GARDE RISQUE DE CHOC ELECTRIQUE M32805 Peut provoquer des chocs lectriques ou endommager le mat riel Couper l alimentation lectrique avant d effectuer le raccordement Si le nouveau thermostat remplace un ancien r gulateur contenant un contact mercure ne pas mettre l ancien r gulateur aux poubelles Contactez le Thermostat Recycling Corporation www switchthestat ca ou le 416 922 2448 pour obtenir de l information sur la fa on et l endroit appropri s de vous d barrasser de votre vieux thermostat A AVIS SUR LE MERCURE 69 2609EFS 03 2 S rie PRO TH2000DH TH1000DH Options d alimentation GARDER LES FILS DANS CETTEZONE OMBRAGEE RETIRER LE CAVALIER INSTALL EN USINE SEULEMENT SI LE SYST ME EST DEUX TRANSFORMATEURS BORNIER DU TH2110DH 3 S10SSDOS BOGYWCRRc RACCORDER LA BORNE C POUR L ALIMENTATION PRINCIPALE EN C A OPTIONNEL SI DES PILES SONT INSTALL ES MF32806 C blage D signation des bornes TH2110DH TH1110DH B Vanne d inversion d clench e en mode de chauffage o Vanne d inversion d clench e en mode de refroidissement G Relais de ventilateur Y Contacteur du compresseur W Relais de chauffage C Commu
25. tador y 1 refrigerador e TH2210DH TH1210DH Para sistemas de bomba de calor para 2 calentadores y 1 regrigerador nicamente Quite el termostato de la placa para pared y g relo para ver el n mero de modelo Tipos de sistema TH2110DH TH1110DH TH2210DH TH1210DH e Sistema de calefacci n a gas a aceite o e Sistema de bomba de calor para 2 el ctrico con aire acondicionado calentadores y 1 refrigerador e Calefacci n de aire agua caliente TH1100DH sistemas de calefacci n de alta g a efectividad bombas de calor para 1 us de calefacci n a gas a aceite o el ctrico calentador y 1 refrigerador vapor gravedad e Calefacci n de aire agua caliente vapor gravedad e S lo calor e Sistemas de calefacci n de 750 mV e S lo calor e S lo calor con ventilador e S lo fr o e Sistemas de calefacci n de 750 mV Debe ser instalado por un t cnico capacitado y experimentado Lea estas instrucciones atentamente Si no sigue estas instrucciones puede da ar el producto u ocasionar un riesgo Necesita asistencia Para obtener asistencia relacionada con este producto visite http customer honeywell com o comun quese con el n mero gratuito del servicio de atenci n al cliente de Honeywell llamando al 1 800 468 1502 Marca registrada de los EE UU Patentes en tr mite O 2011 Honeywell International Inc Todos los derechos reservados TONVdSA Guia de instalacion Instalaci n de la placa para pared
26. tom tico del compresor 6 C WwW W Y unidos por un puente Cc 24 V CA 3 R R Rc unidos por un puente Re Electricidad 1 Sistema s lo calor NENAS TH2110DH TH1110DH Ma2 w Rel de calor Cc 24 V CA 8 R R Rc unidos por un puente Re Electricidad 1 Sistema s lo calor ventilador TH2110DH TH1110DH G Rel del ventilador Ww Rel de calor Cc 24 V CA 3 R R Rc unidos por un puente Re Electricidad 1 Sistema VEAN s lo fr o G Y C R Re TH2110DH TH1110DH M32816 G Rel del ventilador Y Interruptor autom tico del compresor 1 2 NE Heat Only System TH1100DH W C R Not Used w Heat relay M32817 Cc 24Vac common 3 R Electricidad 1 Vea notas abajo NOTAS Especificaciones del cable Use cable para termostato de calibre 18 a 22 No se requiere cable blindado 1 Fuente de alimentaci n Proporciona el medio de desconexi n y la protecci n contra sobrecargas requeridos 21 Para sistemas de 2 transformadores quite el puente 8 Conexi n de 24 V CA opcional 69 2609EFS 03 24 V CA 3 R Rc unidos por un puente Electricidad 1 CE 4 La conexi n com n debe provenir del transformador de refrigeraci n 5 Use terminales O o B para la v lvula inversora 6 Use un trozo peque o de cable no incluido para conectar los terminales W y Y 7 Coloque el interruptor del ventilador en la posici n Heat Pump bomba de calor vea la p gina 5 Serie PRO TH2000DH
27. ur Y Contacteur du compresseur Y Contacteur du compresseur 6 Aux E Relais de syst me de chauffage aux W W Y reli es par un cavalier iliaire 9 Commun 24 V c a 3 Cc Commun 24 V c a 3 R R Rc reli es par un cavalier R Alimentation 1 Re Alimentation 1 Syst me 1C 1F Syst me de TH2110DH chauffage TH1110DH GY WCRRc seulement 1 transformateur m3281 TH2110DH TH1110DH Masat G Relais de ventilateur Y Contacteur du compresseur wW Relais de chauffage W Relais de chauffage C Commun 24 V c a 3 R R Rc reli es par un cavalier Re Alimentation 1 Systeme 1C 1F TH2110DH TH1110DH 2 transformateurs ALAN G Y W CR Rec M32812 G Relais de ventilateur Y Contacteur du compresseur WwW Relais de chauffage c Commun 24 V c a 3 4 R Alimentation transformateur chauffage 1 2 Re Alimentation transformateur refroid issement 1 2 Heat Only System KE TH1100DH W C R Not Ww Relais de chauffage M32817 Cc Commun 24 V c a 3 R Alimentation 1 Voir remarques ci dessous REMARQUES Caract ristiques techniques des fils Utiliser du fil pour thermostat de calibre 18 a 22 Il n est pas n cessaire d utiliser du fil blind 1 Alimentation Fournir au besoin un dispositif de coupure et une protection contre les surcharges 2 Retirer le cavalier dans le cas de syst mes a deux transformateurs 3 Connexion commune 24 V c a en option 69 2609EFS