1. Download Download Current Configuration Saves the current configuration of the IP to 2 x RS 232 Converter to a file Browse Restore Configuration Selects the configuration file to load See the Download button above Restore Click this button to upload the selected configuration file to the IP to 2 x RS 232 Converter page 66 Web Interface Firmware Update UI ver 1 44 Browse Factory Reset Select Settings for reset Select All Network RS 232 Advanced Operation Reboot Browse Firmware Update Click this button to select the firmware file to be uploaded Update Click this button to upload the selected firmware file See the Browse button above Factory Reset Use these check boxes to select the type of factory reset to perform Placing a check mark in the desired check box will select the type of reset Options Select All resets network and RS 232 settings Network resets IP settings only RS 232 resets RS 232 settings only Reset Click this button to reset the selected options to factory default settings Reboot Click this button to reboot the IP to 2 x RS 232 Converter page 67 IP to RS 232 Converter IE Appendix Default Settings The following table lists the default setting of the IP to 2 x RS 232 Converter as displayed under the built in Web interface RS 232 RS 232 Settings Select RS 232 Port 1 De
2. Destination IP Enter the destination where the data will be sent IP address in this field Range per byte 0 255 Destination Port Enter the destination port in this field Range 1024 65535 UDP Echo Useful in troubleshooting and measuring response times and end to end connectivity Options Enable checked Disable unchecked Set Defaults Click this button to reset RS 232 settings to their default values Save Click this button to save any changes page 59 Web Interface Network tab IP Settings MAC Address 00 1C 91 02 20 03 Mode Static IP Address 192 168 1 72 Subnet 255 255 255 0 Gateway 192 168 1 254 HTTP Port Advanced Operation MAC Address The MAC address of the IP to RS 232 Converter The MAC address cannot be changed Mode Select the network mode from the drop down list Options Static DHCP IP Address Enter the IP address of the IP to 2 x RS 232 Converter Range per byte 0 255 Subnet Enter the subnet mask of the IP to 2 x RS 232 Converter Range per byte 0 255 page 60 Advanced Operation Web Interface IP Settings MAC Address 00 1C 91 02 20 03 Mode Static IP Address 192 168 1 72 Subnet 255 255 255 0 Gateway 192 168 1 254 HTTP Port 80 Gateway The gateway router IP address to with the IP to 2 x RS 232 Converter is connected Range per byte 0 255 HTTP Port Select the network mode from the drop down lis
3. Command show serial params show telnet pass show ver data system wide reset use discovery use tcp access use tcp term pass use udp access use udp echo Commands Description Displays the settings of the specified RS 232 port Displays the current TCP terminal password Displays the firmware and hardware version of the IP to RS 232 Converter Restarts the IP to 2 x RS 232 Converter according to the supplied parameter Enables or disables discovery mode Enables or disables TCP access mode Enables or disables the password prompt at the beginning of a Telnet session Enables or disables UDP access Enables or disables UDP echo page 12 Advanced Operation Commands help Displays help on a specific command If no command is specified param7 then a list of all available commands will be displayed Set param1 to full to display a list of all commands Syntax help Parameters param1 Command optional Example fhelp set_add_delim Cmd set_add_delim Set Add delimiter mode Syntax set add delim paraml pram2 Paraml Serial Port 1 2 Param2 On 0 Off e g set_add_delim 1 0 help full Cmd show serial params Show Serial Port Parameters Syntax show serial params Param Serial Port 1 2 e g show_serial_params 1 Cmd set serial mode Set Serial Port mode Syntax set uart mode paraml param2 Paraml Serial Port 1 2 Param2 1 Terminal for Po
4. anregen 8 Configuration using the Gefen Discovery Tool seeeeee 8 Go nfiguration using RS 232 a ec ito aan arme 9 GCOMMANGS ERR TO RA ED 11 Web InterfaGG coo cbe eee Re toe a 53 Using the built in Webinterface corr terr t ene rir tere ie raten 53 RS 232 54 Network tab sun enter 60 Systemi tab sia is iais 66 Default S amp tlings oot rer nr a Rr enne 70 RS 232 nenne nen ea 70 NETWORKS 2er san san co steoeeadioat sn A Ten NEUE RE PRSE TEE DER LIE IU EE 71 SPECICATION near 72 viii IP to RS 232 Converter o 7 x 72 o c gt 7 oO Introcd cueg O IP to 2xRS 232 O Converter page 2 o 7 b 72 o gt 7 Name IP Reset RS 232 1 Power 5V DC IP control RS 232 2 Introduction Description Resets the unit to its default IP settings Connect an RS 232 cable from this port to an RS 232 device See Installation page 4 for more information This LED will glow bright blue when the unit is powered Connect the included 5V DC power supply to this power receptacle Connect an Ethernet cable between this jack and an IP based automation control device Connect an R
5. 72 GEFEN 20600 Nordhoff St Chatsworth CA 91311 1 800 545 6900 818 772 9100 fax 818 772 9120 www gefen com support gefen com
6. 25 Commands set serial params Assigns the settings to the specified serial port Syntax set serial params paraml param2 param3 param4 param5 param6 Advanced Operation Parameters param1 Port tend param2 Word length 5 8 param3 Stop bits 1 2 param4 Parity Parity Description n None e Even o Odd m Mark S Space param5 Baud rate Baud rate 110 4800 300 9600 600 14400 1200 19200 2400 28800 param6 Line delay ms 0 10000 continued on next page page 26 c e x o a o Uo o o f gt o lt Example set serial params 1 8 1 N 19200 1000 Serial port 1 parameters Word length 8 bits Stop bits 1 bit Parity None Baud Rate 19200 Bps Line Delay 1000 ms Related Commands show serial params page 27 Commands Commands set start del Sets the Start Delimiter mode and value for the specified serial port The Start Delimiter must always be specified before the End Delimiter Syntax Advanced Operation set start del paraml param2 param3 Parameters param1 Serial port 1 2 param2 State 0 1 Description 1 TCP bridge Z UDP bridge Terminal mode param3 Start delimiter 00 FF Example set_start_del 1 1 a0 Start delimiter set to ON with a value of a0 Related Commands fset add delim set end del page 28 Advanced Operation Commands set_tcp br port S
7. Syntax Advanced Operation use discovery paraml Parameters paraml State Description 0 Discovery access disabled Discovery access enabled Example fuse discovery 1 Discovery Access is set to Enabled Related Commands show me page 48 Advanced Operation Commands use tcp access Enables or disables TCP access mode This mode must be enabled before using RS 232 command to configure the IP to 2 x RS 232 Converter Syntax fuse tcp access paraml Parameters param1 Value O 1 Description 0 Disable TCP access Enable TCP access Example fuse tcp access 1 TCP Access is set to Enabled Related Commands set tcp br port fset tcp term port set telnet pass fuse tcp term pass page 49 Commands use tcp term pass Enables or disables the use of the password during terminal sessions Syntax Advanced Operation fuse tcp term pass paraml Parameters param1 Value O 1 Description 0 Do not use password Require password Example fuse tcp term pass 1 TCP Terminal password at login is set to ON Related Commands fset tcp br port fset tcp term port set telnet pass fuse discovery page 50 Commands use_udp access Enables or disables UDP access Syntax Advanced Operation fuse udp access paraml Parameters param1 Value O 1 Description 0 Disable UDP access Enable UDP access Example fuse udp access 1 UDP Access
8. I GEFEN IP to RS 232 Converter E Sl al 2h 2922 Release Al Important Safety Instructioms 10 11 12 13 14 15 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this product near water Clean only with a dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install or place this product near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer To reduce the risk of electric shock and or damage to this product never handle or touch this unit or power cord if your hands are wet or damp Do not expose this product to rain or moisture Unplug this apparatus during lightning storms or when unused for long periods of time
9. Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Batteries that may be included with this product and or accessories should never be exposed to open flame or excessive heat Always dispose of used batteries according to the instructions Warranty Information Gefen warrants the equipment it manufactures to be free from defects in material and workmanship If equipment fails because of such defects and Gefen is notified within two 2 years from the date of shipment Gefen will at its option repair or replace the equipment provided that the equipment has not been subjected to mechanical electrical or other abuse or modifications Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair Such repairs are warranted for ninety 90 days from the day of reshipment to the Buyer This warranty is in lieu of all other warranties expressed or implied including without limitation any implied warranty or merchantability or fitness for any particular purpose all of which are expressly disclaimed 1 Proof of sale may be required in order to claim warranty Customers out
10. help for the current page The help window can be moved to any position within the Web browser window RS 232 Settings Help Select RS 232 Port Select the RS 232 port to configure 2 ports are available NOTE Save settings 4 selecting a new port to configure or changes will be lost Description Enter an optional description for the RS 232 output 20 character max RS 232 Mode Select the mode for the selected port TCP Bridge Connect to the device using TCP Slower than UDP guaranteed page 53 Web Interface RS 232 Select RS 232 Port 1 Description None RS 232 Mode TCP Bridge Advanced Operation Gefen IA To RS 232 Bridge EXT IP 2 RS2322 system rm Select RS 232 Port Select the RS 232 port from the drop down list Options 1 2 Description Enter a description for the device that is connected to the selected RS 232 port RS 232 Mode Select the desired mode from the drop down list Options TCP Bridge UDP Bridge Terminal page 54 Web Interface RS 232 Settings Baud Rate Data Bits Parity Stop Bits Advanced Operation Gefen IP To RS 232 Bridge EXT IP 2 RS2322 m Baud Rate Select the baud rate used by the RS 232 device from this drop down list Options 110 300 600 1200 2400 4800 9600 14400 19200 28800 Data Bits Select the number of data bits in each character from this drop down list For most applications 8 data bits sho
11. params 1 Serial port 1 parameters Word length 8 bits Stop bits 1 bit Parity None Baud Rate 19200 Bps Line Delay 1000 ms Related Commands set serial params page 44 Commands show_telnet pass Displays the current TCP terminal password Syntax show telnet pass Advanced Operation Parameters None Example show telnet pass TCP Terminal password b055man Related Commands set_telnet_pass page 45 Advanced Operation show ve r data Displays the current software and hardware version Syntax show ver data Parameters None Example show ver data Firmware version 1 48 Release date May 12 2014 Release time 14 09 37 page 46 Commands Advanced Operation Commands system wide reset Restarts the IP to 2 x RS 232 Converter according to the supplied parameter Syntax system wide reset paraml Parameters param1 Value 0 3 Description 0 Reboot only Al Reset IP settings 2 Reset serial port settings 3 Reset all and reboot Example system wide reset 3 System wide reset in progress Please wait Finish selected operation Device will be reset and all connections will be closed page 47 Commands fuse discovery Enables or disables discovery access mode If this mode is disabled then the IP to 2 x RS 232 Converter will not be discoverable when using the Gefen Discovery Tool The default setting is enabled
12. site Extract the files from the zip file and follow the installation and configuration instructions in the included User Manual Connect the IP to 2 x RS 232 Converter to the network Use the Gefen Discovery Tool to identify the unit on the network Advanced Operation Refer to the Gefen Discovery Tool User Manual for important information on setting the IP address subnet mask gateway HTTP listening port and Telnet listening port The following table lists the diefault IP settings for the IP to 2 x RS 232 Converter 23 192 168 1 255 IP Address Subnet Gateway HTTP Port 5 After the IP settings have been set make sure to click the Save button in the Gefen Discovery Tool to save the changes After saving the changes click the Reboot button to reboot the unit 6 Launch a Web browser and enter the IP address that was assigned to the IP to 2 x RS 232 Converter in the address bar to access the Web interface page 8 and IP Configuration Configuration using RS 232 To configure the IP settings of the IP to 2 x RS 232 Converter using RS 232 commands use the following procedure 1 Connect a null modem crossover cable from the RS 232 port on the computer to the IP to 2 x RS 232 Converter Advanced Operation The null modem cable can be connected to either RS 232 1 or RS 232 2 Diagram 2 1 Configuration using a null modem cable PC with terminal emulation IP to 2 x RS 232 C
13. 0 and 50201 respectively Syntax set udp br port paraml param2 Parameters param Serial port 1 2 param2 Port 1 65535 Example fset udp br port 1 50200 UDP Bridge 1 port set to 50200 Related Commands fset tcp br port set tcp term port fset start del fset udp remote br set udp rip fset udp rport page 32 Advanced Operation Commands set udp echo br Enables or disables UDP bridge echo Syntax set udp echo br paraml param2 Parameters parami Serial port 1 2 param2 State 0 1 Description 0 Disabled Enabled Example set udp echo br 11 The echo of UDP Bridge port 1 is enabled Related Commands set udp br port set udp remote br set udp rip set udp rport page 33 Commands set_udp port Sets the UDP server listening port Syntax Advanced Operation set udp port paraml Parameters param1 Serial port 1 65535 Example set udp port 50007 New UDP server port set to 50007 Related Commands set udp br port fset udp remote br set udp echo br set udp rip set udp rport page 34 Advanced Operation Commands set udp remote br Assigns the UDP Bridge settings for the specified serial port param2 must be entered in dot decimal notation Syntax set udp remote br paraml param2 param3 Parameters parami Serial port 1 2 param2 Address param3 Remote port 1 65535 Example fset udp remote br 1 1
14. 92 168 1 70 51000 Remote UDP bridge 1 set to IP 192 168 1 70 Port 51000 Related Commands set udp port set udp br port set udp echo br set udp rip fset udp rport page 35 Advanced Operation Commands set_udp rip Sets the remote UDP IP address The IP address must be entered using dot decimal notation Each digit can range between 0 and 255 Syntax set udp rip paraml Parameters param1 IP address Example set udp rip 192 168 1 205 New Remote UDP IP set to 192 168 1 205 Related Commands fset udp br port set udp echo br fset udp remote br set udp echo br page 36 Commands set udp rport Sets the remote UDP listening port The default port settings is 50008 Syntax Advanced Operation set udp rport paraml Parameters param1 Port 1 65535 Example set udp rport 50006 New UDP Remote port set to 50006 Related Commands set udp br port set udp echo br set udp remote br set udp rip page 37 Commands show del prms Displays the current delimiter parameters for the specified serial port Syntax Advanced Operation show del prms paraml Parameters param1 Port 1 2 Example show del prms 1 Delimiter Param s in bridge mode UART 1 Line Delay 1000ms Time To Force Send 30ms Count Byte To Force Send 100 Add Delimiters In Data False Use Start Delimiter False Start Delimiter Size 1 Start Delimiter Value AO Use End
15. Delimiter True End Delimiter Size 1 Start Delimiter Value BO Related Commands fset add delim set end del set send byte cnt set send time out set serial params set start del page 38 Advanced Operation show_device descr Displays the device description Syntax show device descr Parameters None Example show device descr Device Description IP BRIDGE Related Commands set_device descr page 39 Commands Advanced Operation show_ipconfig Displays the current TCP IP and UDP settings Syntax show_ipconfig Parameters None Example show_ipconfig MAC addr 00 1C 91 01 0F FF P addr 10 5 64 254 Net Mask 255 255 255 0 Gateway 192 168 1 254 Web Server Port 80 TCP Terminal Server Port 23 TCP Terminal Access Enabled TCP Terminal password at login is set to OFF UDP Access Disabled UDP Server Port 50007 Enable UDP Echo Disabled UDP Remote IP 192 168 1 80 UDP Remote Port 50008 TCP Bridge 1 Port 49200 TCP Bridge 2 Port 49201 UDP Local Bridge 1 Port 50200 UDP Remote Bridge 1 IP 192 168 1 180 Port UDP Remote Bridge 1 Echo Disabled UDP Local Bridge 2 Port 50201 UDP Remote Bridge 2 IP 192 168 1 181 Port UDP Remote Bridge 2 Echo Disabled Discovery Mode Enabled Related Commands set_gateway set_http_port set_ipadd set_netmask set tcp br port set tcp term port set udp br port set udp
16. S 232 cable from this port to an RS 232 device See Installation page 4 for more information page 3 Installation Connection Instructions 1 Connect an Ethernet cable between the IP based control device and the IP control port on the IP to 2 x RS 232 Converter Getting Started An Ethernet switch can also exist between the IP to 2 x RS 232 Converter and the IP based control device see Sample Wiring Diagram below 2 Connect an RS 232 device to each of the RS 232 ports RS 232 1 and RS 232 2 on the IP to 2 x RS 232 Converter 3 Connect the included 5V DC locking power supply to the 5V DC power receptacle on the IP to 2 x RS 232 Converter Do not overtighten the locking power connectors 4 Connect the AC power cord from the power supply to an available electrical outlet Sample Wiring Diagram DB 9 CABLE EEE g GEFEN CAT 5 CABLE EE IP based Automation Control Device Ethernet Switch RS 232 enabled Device EXT IP 2 RS2322 RS 232 enabled Device EXT IP 2 RS2322 page 4 IP to RS 232 Converter RS 232 and IP Configuration Configuration using the Gefen Discovery Tool When using the IP to 2 x RS 232 Converter for the first time it is recommended that the unit be configured using the Gefen Discovery Tool The Gefen Discovery Tool is free software that is available from the Support gt Downloads section ofthe Gefen Web site 1 Download the Gefen Discovery Tool from the Gefen Web
17. e 63 Advanced Operation UDP Settings Enable UDP Access UDP Port Enable UDP Echo V Destination UDP IP Address 192 168 1 129 Destination UDP Port 50008 Discovery Protocol Settings Enable Discovery Web Interface Enable UDP Access Enables or disables UDP access Options Enable checked Disable unckecked UDP Port Sets the UDP port Range 1 1024 Enable UDP Echo Enables or disables UDP echo Options Enable checked Disable unckecked page 64 Advanced Operation Web Interface UDP Settings Enable UDP Access UDP Port Enable UDP Echo V Destination UDP IP Address 192 168 1 129 Destination UDP Port 50008 Discovery Protocol Settings Enable Discovery 7 sanken se Destination UDP IP Address Enter the remote UDP IP address in this field Range per byte 0 255 Destination UDP Port Type the remote UDP port in this field Range 1 1024 Enable Discovery Enables or disables discovery mode This feature must be enabled in order for the Gefen Discovery Tool to detect the unit on a network Options Enable checked Disable unckecked page 65 Advanced Operation Web Interface System tab Download Current Configuration Restore Configuration Browse Restore Warning All current settings will be lost Gefen IP To RS 232 Bridge EXT IP 2 RS2322 2mp
18. echo br set_udp port fset udp remote br fset udp rip set udp rport page 40 Se IP to 2 x RS 232 Converter settings Commands 50000 50001 fuse discovery fuse tcp access fuse tcp term pass fuse udp access fuse udp echo Advanced Operation Commands show me Enables or disables the flashing of the LED on the device When enabled the LED indicator will flash red and blue The default setting is disabled Syntax show_me paraml Parameters param1 State Description 0 Disabled Enabled Example show_me 1 Show me is Enabled Related Commands fuse discovery page 41 Advanced Operation Commands show_serial descr Displays the description of the specified serial port Syntax show_serial descr paraml Parameters param1 Port 11 32 Example show_serial descr 1 Serial port 1 Description DVD Ctrl Related Commands fset serial descr page 42 Advanced Operation Commands show serial mode Displays the mode of the specified serial port Syntax show serial mode paraml Parameters param1 Port 1 2 Example show serial mode 1 Serial port 1 working mode is TCP Bridge Mode Related Commands set serial mode page 43 Commands show_serial params Displays the current settings of the specified serial port Syntax Advanced Operation show serial params paraml Parameters param1 Port 1 2 Example show serial
19. ets the TCP bridge listening port for the specified serial port The default port settings for RS 232 1 and RS 232 2 ports are 49200 and 49201 respectively Syntax set tcp br port paraml param2 Parameters param Serial port 1 2 param2 TCP port 1 65535 Example set tcp br port 1 49200 TCP Bridge 1 port set to 49200 Related Commands set tcp term port set udp br port page 29 Advanced Operation Commands set_tcp term port Sets the TCP terminal listening port The default port settings is 23 Syntax set tcp term port paraml Parameters param1 TCP port 1 65535 Example set tcp term port 23 New TCP Terminal port set to 23 Related Commands set tcp br port set udp br port page 30 Advanced Operation Commands set telnet pass Sets the TCP Terminal password The password cannot exceed 20 characters in length param3 is used to verify the new password The default password is Admin Syntax set telnet pass paraml param2 param3 Parameters param1 Old password 20 chars max param2 New password 20 chars max param3 New password 20 chars max Example set telnet pass Admin b055man b055man TCP Terminal password updated to b055man Related Commands fset tcp br port page 31 Advanced Operation Commands set_udp br port Sets the UDP bridge listening port The default UDP bridge port settings for RS 232 1 and RS 232 2 ports are 5020
20. is available from the Support gt Downloads section of the Gefen Web site IP to 2 x RS 232 Converter is a trademark of Gefen LLC 2014 Gefen LLC All Rights Reserved All trademarks are the property of their respective owners Gefen LLC reserves the right to make changes in the hardware packaging and any accompanying documentation without prior written notice Gs 65 X Cc e This product uses UL or CE listed power supplies Features and Packing List Features A Allows IP control of two RS 232 enabled devices Supports Telnet and UDP protocols Each of the RS 232 devices can be addressed independently Configurable via Web server interface Independently configurable RS 232 baud rate and line delay for each RS 232 port Gefen Discovery Tool compatible Field upgradable firmware via Web server interface Locking power supply connector Surface mountable Packing List The IP to 2 x RS 232 Converter ships with the items listed below If any of these items are not present in your box when vou first open it immediately contact your dealer or Gefen 1 x IP to 2 x RS 232 Converter 1 x 5V DC Power Supply 1 x Quick Start Guide vi vii Table of Core Getting Started Introduction nn 2 Installation e PE A nennen rn 4 Connection Instfclions uai iic ea Bas 4 Sample Wiring Diagralri cec rrr rr erro rte nene 4 2 Advanced Operation RS 232 and IP Configuration
21. is set to Enabled Related Commands fset udp br port set udp echo br fset udp remote br set udp rip set udp rport page 51 Commands use udp echo Enables or disables UDP echo Syntax fuse udp echo paraml Advanced Operation Parameters param1 Value O 1 Description 0 Disable UDP echo Enable UDP echo Example fuse udp echo 1 UDP echo is set to Enabled Related Commands set udp echo br page 52 Web Interface Using the built in Web Interface Access the built in Web interface by entering the IP address of the IP to 2 x RS 232 Converter that was specified in step 3 under Configuration using RS 232 page 9 The built in Web interface is divided into three pages RS 232 Network and System Each main page is represented by a tab at the top of the screen The RS 232 page will always be displayed first Advanced Operation Gefen IP To RS 232 Bridge EXT IP 2 RS Reise Network System ren aacter max RS 252 Mode Soloct the moda for tho selected pot TOP Bridge Connect to the device using TOP Slower thon UDP guaranteed packet order 2 using UDP faster then TCP no guaranteed packet R9 232 SETTINGS Baud Rate Saloct the connected device s baud rate BRIDGING SETTINGS Line Deia re ms iFtime elapses larger than defined here Time out must be an integer 265 Help Click the Help button to display context sensitive
22. ncludes the Start Frame Delimiter used at the end of the preamble of an Ethernet frame Options Enable checked Disable unchecked Start Delimiter Value This value can be up to three ASCII characters 3 bytes in length The value must be entered in hexadecimal e g ODOA which is CR LF The Start Frame Delimiter Value is used by some control systems to filter incoming data Contact Gefen Technical Support for details if you need to use them Range 00 FF wildcard characters such as are acceptable Use End Delimiter Includes the End Frame Delimiter used at the end of a transmission frame Options Enable checked Disable unchecked page 57 Advanced Operation Web Interface Bridging Settings Line Delay ms Force Send ms Force Send bytes Add Delimiters to data sent Use Start Delimiter Start Delimiter Value Use End Delimiter End Delimiter Value TCP Port UDP Local Port End Delimiter Value This value can be up to three ASCII characters 3 bytes in length The value must be entered in hexadecimal Range 00 FF wildcard characters such as are acceptable TCP Port Enter the TCP port in this field Range 0 65535 UDP Local Port Enter the UPD local port in this field Range 1024 65535 page 58 Web Interface UDP Echo Destination IP 192 168 1 180 Destination Port 50000 UDP Echo Enable Advanced Operation
23. nfig show me Show serial descr Show serial mode Description Displays a list of all available commands Enables or disables option to add delimiter to data Sets the device description Sets the end frame delimiter Sets the gateway router IP address Sets the HTTP listening port of the IP to RS 232 Converter Sets the IP address of the IP to RS 232 Converter Sets the subnet mask of the IP to RS 232 Converter Sets the send byte count value for bridging mode Sets the time out value for sending data Assigns a description to the specified RS 232 port Sets the serial mode TCP UDP or Terminal Assigns the settings to the specified RS 232 port Sets the Start Frame delimiter Sets the TCP bridge listening port Sets the TCP terminal listening port Sets the TCP terminal password Sets the UDP bridge listening port Enables or disables UDP bridge echo Sets the UDP listening port Assigns the UDP bridge settings for the specified RS 232 port Sets the remote UDP IP address Sets the UDP remote port Dusplays the current delimiter parameters for the specified serial port Displays the device description Displays the current TCP IP and UDP settings of the IP to 2 x RS 232 Converter Enables or disables the flashing of the LED on the device Displays the current description of the specified RS 232 port Displays the mode of the specified RS 232 port continued on next page page 11 Advanced Operation
24. onverter 2 Use the following COM port settings in the terminal program Baud rate Data bits Stop bits Hardware flow control 3 Set the IP address using the set ipadd command 4 Set the subnet mask using the set netmask command continued on next page page 9 c i gt x E a oO o c gt o lt 10 11 12 IP Configuration Set the gateway router IP address using the set gateway command Set the Telnet listening port using the set tcp term port command Set the HTTP listening port using the set_ http port command Set the UDP remote IP address using the set udp rip command Set the UDP listening port using the set udp port command Set the UDP remote port using the set udp rport command Reboot the IP to 2 x RS 232 Converter to apply all changes Launch the desired Web browser and enter the IP address specified in step 3 in the address bar to access the Web interface Information page 10 Advanced Operation Commands Command help set_add_delim set device descr set end del set gateway set http port set ipadd set netmask set send byte cnt set send time out set serial descr set serial mode set serial params set start del set tcp br port set tcp term port set telnet pass set udp br port set udp echo br set udp port set udp remote br set udp rip set udp rport show del prms show device descr show ipco
25. rtl only 2 TCP Bridge 3 UDP Bridge e g set serial mode 1 2 continued on next page page 13 Advanced Operation help show_ipconfig set_ipadd set_netmask set_gateway set_http_port set tcp term port set udp port show ver data Show telnet pass set telnet pass use tcp term pass set udp rip set udp rport use udp access use udp echo use tcp access set serial params Show serial params set serial mode Show serial mode Show serial connect set serial descr show serial descr set tcp br port set udp br port set udp remote br set udp echo br use discovery set add delim set start del set end del set send time out set send byte cnt show del prms set device descr Show device descr show me system wide reset page 14 Commands Advanced Operation Commands set add delim Enables or disables the option to include a delimiter as part of the data sent to the control system Syntax set add delim paraml param2 Parameters param1 Value 1 2 param2 State 0 1 Description Example set_add_delim 1 Add delimiter mode to ON Related Commands set end del set start del page 15 Advanced Operation set_device descr Commands Sets the device description The device description cannot exceed 30 characters in length Syntax set_device descr paraml Parameters param1 Description Example set device descr LivingRoom Bridge2 Device De
26. scription None RS 232 Mode TCP Bridge Baud Rate 19200 Data Bits 8 Parity None Stop Bits 1 Line Delay ms 0 Force Send ms 30 Force Send bytes 100 Add Delimiters to data sent Disabled Use Start Delimiter Disabled Start Delimiter Value 0 Use End Delimiter Disabled End Delimiter Value 0 TCP Port 49200 UDP Local Port 50200 UDP Echo Destination IP Destination Port UDP Echo 192 168 1 180 50000 Disabled page 70 Default Settings Network a 2 MAC Address Device dependent cannot be changed Mode Static IP Address 192 168 1 72 Subnet 755975952590 Gateway 192 168 1 254 HTTP Port 80 Enable TCP Access Disabled Require Password on Connect Disabled User Name Admin cannot be changed Old Password default password is Admin New Password Confirm New Password Terminal Port 23 Enable UDP Access Disabled UDP Port e 50007 Enable UDP Echo Disabled Destination UDP IP Address 192 168 1 80 Destination UDP Port 50008 Enable Discovery Enabled page 71 del o c o a o lt Specifications Connectors Indicators and Controls RS 232 e 2xDB 9 male IP control 1 x RJ 45 Power 1 x 5V DC locking Power indicator 1 x LED blue IP Reset button 1 x Tact type recessed Operational Power 5V DC Power consumption 1W max Physical Dimensions W x H x D e 4 3 x1 x 3 4 110mm x 26mm x 86mm Unit Weight 0 35 Ibs 0 16 kg page
27. scription changed to LivingRoom Bridge2 Related Commands show device descr page 16 30 chars max Advanced Operation Commands set end del Sets the end delimiter mode and value for the specified serial port The End Delimiter value must be specified in hexadecimal Before executing this command the Start Delimiter must be set using the 4set start del command Syntax set end del paraml param2 param3 Parameters param1 Serial port 1 2 param2 State 0 1 param3 End delimiter 00 FF Example set end del 1 1 ba End delimiter set to ON with a value of ba Related Commands fset add delim set start del page 17 Commands set_gateway Sets the gateway address The gateway must be typed using dot decimal notation The matrix must be rebooted after executing this command The default gateway is 192 168 1 1 Advanced Operation Syntax sgateway paraml Parameters param1 Gateway Example fset gateway 10 5 64 1 New IP Gateway set to 10 5 64 1 Related Commands fset add delim set_ipadd set_netmask show_ipconfig page 18 Advanced Operation set http port Commands Specifies the Web server listening port The unit must be rebooted after executing this command The default port setting is 80 Syntax set http port paraml Parameters param1 Port Example set http port 82 New HTTP port set to 82 Related Commands set gateway
28. set_ipadd set_netmask show_ipconfig page 19 1 1024 Advanced Operation Commands set_ipadd Specifies the IP address of the IP to 2 x RS 232 Converter The IP address must be specified using dot decimal notation The unit must be rebooted after executing this command The default IP address is 192 168 1 72 Syntax set_ipadd paraml Parameters param1 IP address Example fset ipadd 10 5 64 187 New IP set to 10 5 64 187 Related Commands set gateway set http port set end del show ipconfig page 20 Commands set_netmask Sets the subnet mask The subnet mask must be entered using dot decimal notation The unit must be rebooted after executing this command The default net mask is 255 255 2550 Advanced Operation Syntax snetmask paraml Parameters param1 Net mask Example snetmask 255 255 0 0 New IP Mask set to 255 255 0 0 Related Commands set gateway set_ipadd set_http_port show_ipconfig page 21 Advanced Operation Commands set_send_byte cnt Sets the send byte count value for bridging mode Syntax set_send byte cnt paraml Parameters param1 Serial port 1 2 param2 Byte count 0 255 Example set send byte cnt 1 100 UART 1 bridging send byte count limit is set to 100 bytes Related Commands fset add delim set end del set serial mode set start del page 22 Advanced Operation Commands set send
29. side the US are responsible for shipping charges to and from Gefen Copper cables are limited to a 30 day warranty and cables must be in their original condition The information in this manual has been carefully checked and is believed to be accurate However Gefen assumes no responsibility for any inaccuracies that may be contained in this manual In no event will Gefen be liable for direct indirect special incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of such damages The technical information contained herein regarding the features and specifications is subject to change without notice For the latest warranty coverage information refer to the Warranty and Return Policy under the Support section of the Gefen Web site at www gefen com Contacting Gefen Jechnical Technical Support 818 772 9100 800 545 6900 8 00 AM to 5 00 PM Monday Friday Pacific Time Fax 818 772 9120 Email support Bgefen com Web http www gefen com Mailing Address Gefen LLC c o Customer Service 20600 Nordhoff St Chatsworth CA 91311 Product Registration Register your product here http www gefen com kvm Registry Registration jsp Operating Notes When using the IP to 2 x RS 232 Converter for the first time it is recommended that the unit be configured using the Gefen Discovery Tool The Gefen Discovery Tool is free software that
30. t Range per byte 1 1024 page 61 Web Interface TCP Telnet Settings Enable TCP Access v Require Password on Connect 7 User Name Admin Old Password New Password Advanced Operation Confirm New Password Terminal Port Enable TCP Access Enables or disables TCP access Options Enable checked Disable unckecked Reguire Password on Connect Forces password prompt for Telnet sessions Options Enable checked Disable unckecked User Name Displays the user name for TCP sessions The user name cannot be changed Old Password Type the current old password in this field The password is automatically masked when entered The password is case sensitive The default password is Admin Maximum length 8 characters page 62 Advanced Operation Web Interface TCP Telnet Settings Enable TCP Access v Require Password on Connect 7 User Name Admin Old Password New Password Confirm New Password Terminal Port New Password Type the new password in this field The password is automatically masked when entered The password is case sensitive Maximum length 8 characters Confirm Password Re type the new password in this field The password must match the same password that was entered in the New Password field Maximum length 8 characters Terminal Port Type the Telnet listening port in this field Range 1 1024 pag
31. time out Sets the time out value for sending data collected from a device to the control system in Bridging Mode when a Start Delimiter and End Delimiter have been set If no data has been collected for the specified time the data is sent without waiting for the End Delimiter Syntax set_send time out paraml Parameters param1 Serial port 1 2 param2 Time out ms 0 255 Example set send time out 1 30 UART 1 bridging sent Time Out is set to 30 ms Related Commands fset add delim set end del set serial mode set start del page 23 Advanced Operation Commands set_serial descr Assigns a descriptor to the specified serial port The serial port description cannot exceed 20 characters in length The default description is None Syntax set_serial descr paraml param2 Parameters param Port 1 2 param2 Description 20 chars max Example set_serial descr 1 DVD Ctrl Serial port 1 Description DVD Ctrl Related Commands show serial descr page 24 Advanced Operation Commands set serial mode Sets the mode of the specified serial port The default mode for all serial ports 1 2 is TCP Bridge mode Syntax set serial mode paraml param2 Parameters param1 param2 Example set serial mode 1 2 Description TCP bridge UDP bridge Terminal mode Serial port 1 working mode is TCP Bridge Mode Related Commands show serial mode page
32. uld be selected 9 data bits are rarely used Options 8 9 Parity Select the parity bit type from this drop down list Options None Even Even Stick Odd Odd Stick Stop Bits Select the number of stop bits from this drop down list Options 1 2 page 55 Advanced Operation Web Interface Bridging Settings Line Delay ms Force Send ms Force Send bytes Add Delimiters to data sent Use Start Delimiter Start Delimiter Value Use End Delimiter End Delimiter Value TCP Port UDP Local Port Line Delay ms Enter the line delay in this field Range 0 10000 Force Send ms If no data is received from the controlled device within the specified time interval send the collected data to the control system Range 0 30 Force Send bytes If the specified number of bytes is received from the controlled device send the collected data to the control system Range 0 255 page 56 Web Interface Bridging Settings Line Delay ms Force Send ms Force Send bytes Add Delimiters to data sent Use Start Delimiter Start Delimiter Value Advanced Operation Use End Delimiter End Delimiter Value TCP Port UDP Local Port Add Delimiters to data sent Include the delimiter characters in the data sent to the control system Check the Add box to enable this feature Options Enable checked Disable unchecked Use Start Delimiter I
Download Pdf Manuals
Related Search
Related Contents
TPA3122D2 EVM User's Guide (Rev. A Asrock G41MH/USB3 R2.0 CPS225/CPX275 - image.img Simpli Home INT-AXCAMH-MED-DAB Installation Guide Crown Audio MA-2402 Stereo Amplifier User Manual Cópia de Fotos - Lojas Colombo Télécharger AP バイシクル リアワークスタンド 取扱説明書 3 - Sulky Burel 1 安全のために必ず守ってください Copyright © All rights reserved.
Failed to retrieve file